Transcript

2011 © Interprise Innovation | Confidential

Data Center Build Services

2011 © Interprise Innovation | Confidential

Established in 2005,Interprise Global has been launching a platform for engineering entrepreneurs with diverse experience in corporate services across India . We cater end to end services and product support for SME customers across south of india. Drawing on proven expertise, we help you manage and compile your requirements and analyze it, highlighting critical measures, and ensuring that you are reliably informed about the requirements and our performance. Our experts have several years of experience in space planning, building interiors/exteriors,construction, corporate services, building management solutions, facilities management, logistics, data & telephony, data center build, networking . We focus continuously on increasing the efficiency and reliability with the support of world class products and services .

About INTERPRISE

2011 © Interprise Innovation | Confidential

Fire

Detection

Fire

Supp ( Wet )

Fire

Supp ( Dry )

VESDA

Systems

Paging

System

Access

Control

CCTV

Systems

Intrusion

Systems

Waste Water

Management

Water Leak

Systems

HVAC

Systems

Ventilation

System

Chiller

Management

Lighting

Control

DG Set

Monitoring

Perimeter

Protection

Energy

Metering

Gate

Automation

Elevator

Control

Third Party

PAC Raised Floor

UPS Networking

Our Expertise

2011 © Interprise Innovation | Confidential

Business

NeedPrepare Design Acquire Implement

The Idea

PLAN BUILD

System Planning : Data Center Projects

2011 © Interprise Innovation | Confidential

Data Centre Tier Classifications.

2011 © Interprise Innovation | Confidential

Tier 1:Protect Hardware

Load

Mains Source

TVSS and / orConditioner

PDU

2 x 9

Tier 2:Preserve Data

Load

UPS

PDU

Mains Source

4 x 9

N+1 Redundant

Tier 4 (2N) No Downtime (Dual Bus)

Dual Input PDU

LBSUPS 1

Load

STS

Load

STS

Load

Dual Input Load

Mains Source / Generator #2

Mains Source / Generator #1

UPS 2

PDU

PDUPDU

PDUPDU

6-9 x 9

Tiers of Protection

1+N Redundant

Load

PDU

Mains Source w/ ATS & Generator

UPS 2UPS 1

5 x 9

Tier 3 (N+1): Increase Uptime

2011 © Interprise Innovation | Confidential

Criticality Level Nature of Business System design

Tier - 1(Lowest)

Small Businesses Cash Based. Low IT dependence. Low Online presence.

Many Single Point Failures No DG backups Vulnerable to extreme weather conditions. Can sustain only 10mins power outage.

Tier – 2 Many Servers Some Online Revenue gene’n Phone & email dependent.

Some redundancy in power. DG backup available. Formal data rooms. Can sustain only 24hrs power outage.

Tier – 3 Multi country businesses. Major Online Revenue gene’n Hi IT & VoIP dependencies. High downtime cost.

Dual power paths. Redundant power systems. Careful & planned data rooms. Can sustain only 72hrs power outage.

Tier - 4(Highest)

Multi country & million business. Majority Online Revenue gene Entire IT & VoIP dependencies. Extremely High downtime cost.

Dual independent power paths. 2 N Redundant power systems. Stringent Site selections. Can sustain only 96hrs power outage. 24/7

manned staff.

Data Center Criticality's - 2

2011 © Interprise Innovation | Confidential

UPS and its environment

MainsOrDG

Poor qualityPower

UPS

Good qualityPower

CriticalLoad –

Physical Environment

Battery

2011 © Interprise Innovation | Confidential

12

Growing infrastructures, growing needs

Room CoolingHot/Cold aisle approach

- Heat density limitations- High tot cost of ownership

Floor Mounts& supplemental coolingbased on open architecture

- Resolve hot spots, zones, rooms issues- Applicable to existing data centers

Closed LoopRack Cooling

5 kW/rack 5-16 kW/rack

- High heat density- Safety, redundancy, emergency options- Low installation Cost

up to 24 kW/Rack

2011 © Interprise Innovation | Confidential

Adaptive Cooling Architecture

• Traditional Floor-Mounts through the first 5 kW/rack• Supplemental cooling above that level• Closed Loop Rack Cooling for high density

kW / Rack

Base LevelFloor-Mounts

4 8 12 16

SupplementalCooling

20

Closed Loop Rack Cooling

2011 © Interprise Innovation | Confidential

Air distribution

2011 © Interprise Innovation | Confidential

Human Factors• Unauthorized Access• Unintentional Errors• Negligence• Malfeasance• Inability to ID Root Cause

Environmental:• Temperature• Humidity• Airflow• Fire

Power• Outages• Quality

IT Security Threats

Source: Fleishman-Hillard Research

The Gap in IT Security

2011 © Interprise Innovation | Confidential

Smoke Detector

Heat Detector

Manual Call Point

Addressable Control module for hooter

Fire Alarm Panel

System Architecture

Fire Alarm System

Addressable Relay module for Tripping

Addressable Monitor module

VESDA Access Controller

Extinguishing System

WLD

SOUND MANAGEMENT SYSTEM

PA System

H/W Integration

2011 © Interprise Innovation | Confidential

Gas Based Extinguishing System

2011 © Interprise Innovation | Confidential

Reader Interface Module

Reader-IN

EM Lock

Magnetic Contact

Reader-OUT

System Architecture - Access Control System

ACS Workstation

4 Reader Controller

Ethernet

Reader Interface Module

Reader-IN

EM Lock

Magnetic Contact

PTE Button

Security System

2011 © Interprise Innovation | Confidential

Color Monitor

Digital Video Recorder

Ethernet LAN

Cameras 1 to 16

Access Control

Summary

References

CCTV System – Analog

2011 © Interprise Innovation | Confidential

Water Leak Detection System

2011 © Interprise Innovation | Confidential

Rodent Repellent system

This system is placed in ceiling void, Raised floor void in Computer Room ,in Technical Room, Equipment Room, and Ceiling Void in office areas

2011 © Interprise Innovation | Confidential

Building Management Architecture

DDC

PAC

Electrical Systems

FIELD

DEVICES

Field Sensor

a) Chillers b) AHUsc) Utility Monitoringd) DG

Water Leak Detection

Building LAN

GATEWAYGATEWAYGATEWAY

UPS

2011 © Interprise Innovation | Confidential

Typical Project Approach of Interprise :

• Design Basis for IDC including conceptual Plan• Preparation of Techno-Commercial Offer / Proposal for Approval• Preparation & submission of Drawings to Statutory Authority• Detailed Engineering & preparation of final drawings• Prepare Complete BoQ & Technical recommendation of the

equipment• Site Preparation & Construction - Civil + Structural +

Architectural• Receipt of all utilities and equipment at the site • Electrical (Internal & External)• Installation of HVAC / Utilities• Fire Fighting, BMS etc• Testing and Commissioning • Ready for Electronics (RFE)

2011 © Interprise Innovation | Confidential

they recommend Us!!

Completed projects

1) Legal solutions Group (LSG) leela Infopark Kochi Tier 3 data center :750 Sqft2) Federal bank Near DR at head office for Sify technologies 3) Extension of DR at Technopark for Kerala IT mission 4) Tier 3 Data center for E Creations -Lucknow

Ongoing projects

5) Regional cancer center Data center 3500 Sqft for HP Thriuvanthapuram 6) Near Dr for South Indian bank for Reliance communications 7) 250 Sqft Data center for Souriau Esterline Kochi

2011 © Interprise Innovation | Confidential

Corporate Office - COCHIN

Interprise Innovation projects Private limited

XI/105 B , Civil Lane Road , Padamughal Kakkanad Cochin -682030

Ph :+91 484 403 3640-3644 |Fax :+91 484 2426270 |GSM :+91 999 544 1220

www.interprise.in

www.interpriseglobal.com

TRIVANDRUM

INTERPRISE INNOVATION TC 26/846,Womens College RoadVazhuthacad, Thycaud P.O |Thiruvanthapuram, Kerala-695014Ph :+91 471 406 7666 - 7669 (4 nos) Fax :+91 471 406 7667