iipl data centerbuild services (c) 2015
Embed Size (px)
TRANSCRIPT

2011 © Interprise Innovation | Confidential
Data Center Build Services

2011 © Interprise Innovation | Confidential
Established in 2005,Interprise Global has been launching a platform for engineering entrepreneurs with diverse experience in corporate services across India . We cater end to end services and product support for SME customers across south of india. Drawing on proven expertise, we help you manage and compile your requirements and analyze it, highlighting critical measures, and ensuring that you are reliably informed about the requirements and our performance. Our experts have several years of experience in space planning, building interiors/exteriors,construction, corporate services, building management solutions, facilities management, logistics, data & telephony, data center build, networking . We focus continuously on increasing the efficiency and reliability with the support of world class products and services .
About INTERPRISE

2011 © Interprise Innovation | Confidential
Fire
Detection
Fire
Supp ( Wet )
Fire
Supp ( Dry )
VESDA
Systems
Paging
System
Access
Control
CCTV
Systems
Intrusion
Systems
Waste Water
Management
Water Leak
Systems
HVAC
Systems
Ventilation
System
Chiller
Management
Lighting
Control
DG Set
Monitoring
Perimeter
Protection
Energy
Metering
Gate
Automation
Elevator
Control
Third Party
PAC Raised Floor
UPS Networking
Our Expertise

2011 © Interprise Innovation | Confidential
Business
NeedPrepare Design Acquire Implement
The Idea
PLAN BUILD
System Planning : Data Center Projects

2011 © Interprise Innovation | Confidential
Data Centre Tier Classifications.

2011 © Interprise Innovation | Confidential
Tier 1:Protect Hardware
Load
Mains Source
TVSS and / orConditioner
PDU
2 x 9
Tier 2:Preserve Data
Load
UPS
PDU
Mains Source
4 x 9
N+1 Redundant
Tier 4 (2N) No Downtime (Dual Bus)
Dual Input PDU
LBSUPS 1
Load
STS
Load
STS
Load
Dual Input Load
Mains Source / Generator #2
Mains Source / Generator #1
UPS 2
PDU
PDUPDU
PDUPDU
6-9 x 9
Tiers of Protection
1+N Redundant
Load
PDU
Mains Source w/ ATS & Generator
UPS 2UPS 1
5 x 9
Tier 3 (N+1): Increase Uptime

2011 © Interprise Innovation | Confidential
Criticality Level Nature of Business System design
Tier - 1(Lowest)
Small Businesses Cash Based. Low IT dependence. Low Online presence.
Many Single Point Failures No DG backups Vulnerable to extreme weather conditions. Can sustain only 10mins power outage.
Tier – 2 Many Servers Some Online Revenue gene’n Phone & email dependent.
Some redundancy in power. DG backup available. Formal data rooms. Can sustain only 24hrs power outage.
Tier – 3 Multi country businesses. Major Online Revenue gene’n Hi IT & VoIP dependencies. High downtime cost.
Dual power paths. Redundant power systems. Careful & planned data rooms. Can sustain only 72hrs power outage.
Tier - 4(Highest)
Multi country & million business. Majority Online Revenue gene Entire IT & VoIP dependencies. Extremely High downtime cost.
Dual independent power paths. 2 N Redundant power systems. Stringent Site selections. Can sustain only 96hrs power outage. 24/7
manned staff.
Data Center Criticality's - 2

2011 © Interprise Innovation | Confidential
UPS and its environment
MainsOrDG
Poor qualityPower
UPS
Good qualityPower
CriticalLoad –
Physical Environment
Battery

2011 © Interprise Innovation | Confidential
12
Growing infrastructures, growing needs
Room CoolingHot/Cold aisle approach
- Heat density limitations- High tot cost of ownership
Floor Mounts& supplemental coolingbased on open architecture
- Resolve hot spots, zones, rooms issues- Applicable to existing data centers
Closed LoopRack Cooling
5 kW/rack 5-16 kW/rack
- High heat density- Safety, redundancy, emergency options- Low installation Cost
up to 24 kW/Rack

2011 © Interprise Innovation | Confidential
Adaptive Cooling Architecture
• Traditional Floor-Mounts through the first 5 kW/rack• Supplemental cooling above that level• Closed Loop Rack Cooling for high density
kW / Rack
Base LevelFloor-Mounts
4 8 12 16
SupplementalCooling
20
Closed Loop Rack Cooling

2011 © Interprise Innovation | Confidential
Air distribution

2011 © Interprise Innovation | Confidential
Human Factors• Unauthorized Access• Unintentional Errors• Negligence• Malfeasance• Inability to ID Root Cause
Environmental:• Temperature• Humidity• Airflow• Fire
Power• Outages• Quality
IT Security Threats
Source: Fleishman-Hillard Research
The Gap in IT Security

2011 © Interprise Innovation | Confidential
Smoke Detector
Heat Detector
Manual Call Point
Addressable Control module for hooter
Fire Alarm Panel
System Architecture
Fire Alarm System
Addressable Relay module for Tripping
Addressable Monitor module
VESDA Access Controller
Extinguishing System
WLD
SOUND MANAGEMENT SYSTEM
PA System
H/W Integration

2011 © Interprise Innovation | Confidential
Gas Based Extinguishing System

2011 © Interprise Innovation | Confidential
Reader Interface Module
Reader-IN
EM Lock
Magnetic Contact
Reader-OUT
System Architecture - Access Control System
ACS Workstation
4 Reader Controller
Ethernet
Reader Interface Module
Reader-IN
EM Lock
Magnetic Contact
PTE Button
Security System

2011 © Interprise Innovation | Confidential
Color Monitor
Digital Video Recorder
Ethernet LAN
Cameras 1 to 16
Access Control
Summary
References
CCTV System – Analog

2011 © Interprise Innovation | Confidential
Water Leak Detection System

2011 © Interprise Innovation | Confidential
Rodent Repellent system
This system is placed in ceiling void, Raised floor void in Computer Room ,in Technical Room, Equipment Room, and Ceiling Void in office areas

2011 © Interprise Innovation | Confidential
Building Management Architecture
DDC
PAC
Electrical Systems
FIELD
DEVICES
Field Sensor
a) Chillers b) AHUsc) Utility Monitoringd) DG
Water Leak Detection
Building LAN
GATEWAYGATEWAYGATEWAY
UPS

2011 © Interprise Innovation | Confidential
Typical Project Approach of Interprise :
• Design Basis for IDC including conceptual Plan• Preparation of Techno-Commercial Offer / Proposal for Approval• Preparation & submission of Drawings to Statutory Authority• Detailed Engineering & preparation of final drawings• Prepare Complete BoQ & Technical recommendation of the
equipment• Site Preparation & Construction - Civil + Structural +
Architectural• Receipt of all utilities and equipment at the site • Electrical (Internal & External)• Installation of HVAC / Utilities• Fire Fighting, BMS etc• Testing and Commissioning • Ready for Electronics (RFE)

2011 © Interprise Innovation | Confidential
they recommend Us!!
Completed projects
1) Legal solutions Group (LSG) leela Infopark Kochi Tier 3 data center :750 Sqft2) Federal bank Near DR at head office for Sify technologies 3) Extension of DR at Technopark for Kerala IT mission 4) Tier 3 Data center for E Creations -Lucknow
Ongoing projects
5) Regional cancer center Data center 3500 Sqft for HP Thriuvanthapuram 6) Near Dr for South Indian bank for Reliance communications 7) 250 Sqft Data center for Souriau Esterline Kochi

2011 © Interprise Innovation | Confidential
Corporate Office - COCHIN
Interprise Innovation projects Private limited
XI/105 B , Civil Lane Road , Padamughal Kakkanad Cochin -682030
Ph :+91 484 403 3640-3644 |Fax :+91 484 2426270 |GSM :+91 999 544 1220
www.interprise.in
www.interpriseglobal.com
TRIVANDRUM
INTERPRISE INNOVATION TC 26/846,Womens College RoadVazhuthacad, Thycaud P.O |Thiruvanthapuram, Kerala-695014Ph :+91 471 406 7666 - 7669 (4 nos) Fax :+91 471 406 7667