Diaphragm Seals
R
Diaphragm Seal Mounting OptionsDiaphragm Seal Assembly withCooling Element
WIKA Datasheet Cooling Element
Applications
Direct mounted system is required
High: >212°F Process Temperature
Low: < -40°F Process Temperature
Special Features
Specically designed heat-sink
Works in combination with diaphragm seal Dissipates temperatures up to 300°F in normal conditions
Standard Features
Cooling Element
Intended to protect the pressure instrument from high or low
process temperature. Air ow across heat exchanging ns
reduces or increases the temperature of the system ll uid to
protect the pressure measuring instrument.
The cooling element is recommended for process
temperatures above 212°F. It is direct mounted between thepressure instrument and the diaphragm seal. Silicone ll
is recommended. Effective temperature reductions of 300°F
depending upon ambient conditions. All stainless steel
construction is back-welded to stainless steel upper
housing or fange.
Capillary line
Stainless steel capillary with stainless steel armor provides
a connection between the pressure instrument and the dia-
phragm seal. It protects the pressure instrument from high or
low process temperatures and provides remote reading.
The capillary should be selected as short as possible, sincechanges in ambient temperature conditions may considerably
affect the accuracy and response time of the pressure instru-
ment. Standard length is ve feet; other lengths 2mm and
0.6mm are available upon request.
Installation on mechanical gauges normally requires a gauge
support and gauge adaptor or other surface mounting
provisions.
Shown with XSEL™ Process Gauge and
M93X.D1 All-Welded System
Diaphragm Seal Assembly with Capillary Line,
Gauge Support and Adaptor
Any level difference between pressure instrument and dia-
phragm seal will cause a pressure indication error. The level
difference can be compensated for during calibration of the
diaphragm seal assembly if level difference is known.
Minor corrections can be made on site by means of an
adjustable pointer or zero adjustment of the pressure instru-
ment.
Gauge Support and Adaptor
Provides wall mounting of pressure instrument by clamping to
gauge adaptor. Material: gauge support - aluminum or stainless
steel, gauge adaptor - stainless steel.
WIKA Datasheet Cooling Element · 12/2012 Page 1 of 4

8/13/2019 DS ACC Cooling Element en Us 17070
http://slidepdf.com/reader/full/ds-acc-cooling-element-en-us-17070 2/4
Diaphragm Seal Mounting Option Table
Field No. Code Description
Instrument Mounting To Seal
DZZ Direct assembly
KZS Cooling element
MK0 Unarmored stainless steel capillary
MK1 Armored stainless steel capillary
MK2 PVC coated, armored stainless steel capillary
1 ??? Other - please specify
Capillary Line Length
ZZ Direct Assembly or Cooling Element
F1 5 ft length
F2 10 ft length
F3 15 ft length
F4 20 ft length
2 ?? Other - please specify
Connection to Seal
N4 ¼" NPT female
N2 ½" NPT female
WI Weld-in connection (*oered only for capillary or cooling element
mounting to 316 SS seal upper housings) (SS-to-SS only)
3 ?? Other - please specify (SS-to-SS only)
System Fill Fluid
A1 KN2 - Silicone oil (50 cSt)
F1 KN7 - Glycerine (99.7%)
E2 KN8 - Fluorolube® FS-5
G1 KN12 - Glycerine/Water (86.5%/13.5%)
B1 KN17 - Low temperature silicone oil (4 cSt)
E1 KN21 - Halocarbon® 6.3
A2 KN32 - High temperature silicone oil
K5 KN59 - NEOBEE® M20
B2 KN68 - Silicone oil (10 cSt)
J2 KN92 - Medicinal white mineral oil
K3 KN93 - Food grade silicone oil
4 ?? Other - please specify
Additional Mounting Options
ZZZZ Without
ID20 Capillary Internal Diameter 0.079” (standard)
ID10 Capillary Internal Diameter 0.039”
ID06 Capillary Internal Diameter 0.024” SSTW Tack-weld instrument connection (SS-to-SS only)
SSBW Back-weld instrument connection (SS-to-SS only)
ALMT Aluminum gauge support with stainless steel adaptor
5 SSMT Stainless steel gauge support with stainless steel adaptor
Mounting Option Table - ___ __ __ __ - ____ ZZZ
Page 2 of 4 WIKA Datasheet Cooling Element · 12/2012

8/13/2019 DS ACC Cooling Element en Us 17070
http://slidepdf.com/reader/full/ds-acc-cooling-element-en-us-17070 3/4
4” Cooling Element
T KEY A B P/N
¼” X ¼” in. 4.68 4.051600885
mm 119 103
½” X ½” in. 4.68 3.861584510
mm 119 98
¼” X weld in. 4.68 4.05
1653512mm 119 103
½” X weld” in. 4.68 3.862081849
mm 119 98
4” Cooling Element
Cooling Performance
Gauge SampleTransmitter Sample
1Food grade ll uids; for sanitary applications2Inert ll uids; for oxidizing process media applications
WIKA Datasheet Cooling Element · 12/2012 Page 3 of 4

8/13/2019 DS ACC Cooling Element en Us 17070
http://slidepdf.com/reader/full/ds-acc-cooling-element-en-us-17070 4/4
Typical Capillary
Gauge Support
KEY A B C D F G H I Material P/N
in. 3.35 2.56 2.20 2.99 1.02 .87 .55 3.94SS 9091882
AL 9091858
KEY A B C T Y P/N
in.
2.95 1.18 1.02 ½ x ½ 1 9091416
2.35 1.18 X ½ x CPL
CONNECTION1 2084619
2.35 1.18 X ¼ x CPL
CONNECTION1 50183851
1/4 NPT-F
X
1/4 NPT-M
1/2 NPT-F
X
1/2 NPT-M
Male weld nipple
X
Male weld nipple
5 ft 1030876 1030850 2080494
10 ft 1632540 1655752 2082152
15 ft 50249584 2080141
Gauge Adaptor
How to Order
Add information Sample: Reference page*
Instrument: 232.34 4.5 200 psi 1/2L 57-67
D/S: 990.FR-A-SM20-1-1B-C2-C2-C2-Z-Z-Z
Mounting: DZZZZ-N2-ZZZZ-ZZZ 229
System fll: Silicon oil KN2 228
Additional: N/A
*2013 Price List
Page 4 of 4 WIKA Datasheet Cooling Element · 12/2012