energiezÄhler energy counting ... - ime … · static meter conto d4-pt submetering applications...

8
Conto D4-Pt Static Meter submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module Single and three-phase network Direct connection : three-phase 400-415V single-phase 230-240V or Direct connection: single and three-phase 100-115V Connection by VT/100 and/110V Isolated current input Connection by CT/1A and /5A (same reference) Programmable external VT and CT ratio Programmable pulse output RS485 communication Sealable housing and terminal block External interfaces : Ethernet communication (NT809-NT891) RS232 communication (NT693) ENERGIEZÄHLER ENERGY COUNTING NT672 09- 2015 13a Ed. pag.1/8 Statischer Energiezähler Anwendung zur internen Zählung für Nieder-, und Mittelspannungsnetze (mit angegebenen Grenzwerten für Wandlerübersetzungen) 4 TE Wechselstromnetz und Drehstromnetz Direktanschluss : Drehstromnetz 400-415V Wechselstromnetz 230-240V oder Direktanschluss: einphasig und dreiphasig 100-115V Anschluss an Wandler sek. /100 und /110V Galvanisch getrennte Stromeingänge Anschluss an Wandler sek. /1A und /5A (gleiches Modell) Wandlerübersetzungen CT und VT programmierbar Impulsausgang programmierbar Kommunikation RS485 Gehäuse und Anschlussklemmen plombierbar Externe Schnittstellen : Kommunikation Ethernet (NT809-NT891) Kommunikation RS232 (NT693) DISPLAY 0 0 065800 k W h 4 Wirk-, Blindenergie (gesamt) Total Active and Reactive Energy 4Wirk-, Blindenergie (teil) Partial Active and Reactive Energy 4Betriebsstundenzähler Working hours and minutes 4Wirkenergie (teil) Partial Active Energy 4Max. und mittlerer Strom Max. demand and instantaneous current 4Max. und mittlere Leistung Max. demand and instantaneous power 4Spannungen - Frequenz - Leistungsfaktor - Betriebsstundenzähler Voltage - Frequency Power factor - Hour meter CONTO D4 prog page page CE4DT06A4 230(400)V-240(415)V 10(63)A 50-60Hz Cl.1- Wh / Cl.2 - varh METERING LED: 1imp/Wh RS485 communication Pulse output 13 20 2597890001 MADE IN ITALY Conto D4-Pd 3 7265800 k Wh RS485 ETHERNET RS232 IMPULS PULSE KONTAKT

Upload: dokhanh

Post on 06-Aug-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

Conto D4-PtStatic Metersubmetering applicationsfor low, medium voltagenetworks(with limits indicated for CTand VT ratio)4 module

Single and three-phase networkDirect connection :three-phase 400-415Vsingle-phase 230-240VorDirect connection:single and three-phase 100-115VConnection by VT/100 and/110V

Isolated current inputConnection by CT/1A and /5A(same reference)

Programmable external VT and CT ratioProgrammable pulse outputRS485 communicationSealable housing and terminal block

External interfaces :Ethernet communication (NT809-NT891)RS232 communication (NT693)

COMUNICAZIONEMULTIMISURA CONTEGGIO ENERGIA CONTROLLO E GESTIOINE

PROTEZIONESENSORI DI CAMPO MISURE CONTROLLOMISURE GRANDEZZE SINGOLE

ENERGIEZÄHLERENERGY COUNTING

USCITA CON IMPULSI CONTEGGIO ENERGIA

BUS SPECIALI

USCITA CON ALLARME

COMUNICAZIONEUSCITA ANALOGICA

USCITA CON IMPULSI CONTEGGIO ENERGIA

BUS SPECIALI

USCITA CON ALLARME

COMUNICAZIONEUSCITA ANALOGICA

NT6

72 0

9- 2

015

13a

Ed.

pag

.1/8

Statischer EnergiezählerAnwendung zur internen Zählung

für Nieder-, undMittelspannungsnetze

(mit angegebenen Grenzwertenfür Wandlerübersetzungen)

4 TE

Wechselstromnetz und DrehstromnetzDirektanschluss :

Drehstromnetz 400-415VWechselstromnetz 230-240V

oderDirektanschluss:

einphasig und dreiphasig 100-115VAnschluss an Wandler sek. /100 und /110V

Galvanisch getrennte StromeingängeAnschluss an Wandler sek. /1A und /5A

(gleiches Modell)

Wandlerübersetzungen CT und VTprogrammierbar

Impulsausgang programmierbarKommunikation RS485

Gehäuse und Anschlussklemmen plombierbar

Externe Schnittstellen :Kommunikation Ethernet (NT809-NT891)

Kommunikation RS232 (NT693)

DISPLAY

00 065800k W h

Energia Attiva Totale Total Active Energy

Energia Reattiva TotaleTotal Reactive Energy

Energia Attiva ParzialePartial Active Energy

Energia Reattiva ParzialePartial Active Energy

Corrente Istantanea e MediaMax. Demand and Istantaneous Current

Potenza Istantanea e MediaMax. Demand and Istantaneous Power

Tensione - Frequenza - Fattore di PotenzaVoltage - Frequency - Power Factor

4 Wirk-, Blindenergie (gesamt)Total Active and Reactive Energy

4Wirk-, Blindenergie (teil)Partial Active and Reactive Energy

4BetriebsstundenzählerWorking hours and minutes

4Wirkenergie (teil)Partial Active Energy

4Max. und mittlerer StromMax. demand and instantaneous current

4Max. und mittlere LeistungMax. demand and instantaneous power

4Spannungen - Frequenz - Leistungsfaktor - BetriebsstundenzählerVoltage - FrequencyPower factor - Hour meter

CONTO D4

pprroogg

pagepageCE4DT06A4230(400)V-240(415)V10(63)A 50-60Hz Cl.1- Wh / Cl.2 - varhMETERING LED: 1imp/WhRS485 communication Pulse output13 20 2597890001 MADE IN ITALY

Conto D4-Pd

3 7 265800k W h

RS485

ETHERNET

RS232

IMPULS • PULSE

KONTAKT

Page 2: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

AUSGANG

OUTPUT

ANZEIGE

DISPLA

YEINGANG

INPUT

MODELL MODEL D4-Pt

BESTELLNUMMER CODE CE4DT1...

DATENBLATT TECHNICAL NOTE NT672

NETZART NETWORK NS-MS/LV-MV

ZERTIFIZIERUNGCERTIFICATION

MID

ANSCHLUSSCONNECTION

Wechselstromnetz / Single-phase 4

DrehstromnetzThree-phase

3- Leiter / wire 4

4- Leiter / wire 4

NENNWERTRATED VALUE

Spannung (Phase-Phase)Voltage (phase-phase)

400...415V100-115V

StromCurrent

1A / 5A

STROMEINGANGINPUT CURRENT

Messung über Shunt (intern)Dedicated CT (shunt)

Isoliert / Insulated 4

WANDLERÜBERSETZUNGPROGRAMMIERBARPROGRAMMABLE RATIO

CT / CT 1...9.999

VT / VT 1...1500,0

Max. CT x VTMax. CT x VT

5.000.000 (1A)1.000.000 (5A)

HILFSSPANNUNGAUXILIARY SUPPLY

Selbstversorgend / Selfsupplied 4

230V ac / ac

WIRKENERGIEACTIVE ENERGY

Gesamt / Total 4

Teil / Partial 4

Doppeltarifzähler / Double tariff

Genauigkeit / Accuracy Kl.1 EN/IEC 62053-21

BLINDENERGIEREACTIVE ENERGY

Gesamt / Total 4

Teil / Partial 4

Doppeltarif / Double tariff

Genauigkeit / Accuracy Kl.2 EN/IEC 62053-23

SPANNUNGVOLTAGE

je Phase / Phase

Verkettete / Linked 4

STROMCURRENT

je Phase / Phase 4

Neutral / Neutral

LEISTUNGPOWER

Wirkleistung / Active 4

Blindleistung / Reactive 4

Scheinleistung / Apparent 4

Blindleistung je Phase / Phase Active

Wirkleistung je Phase / Phase reactive

Mittlere Wirkleistung / Max. demandMax. Mittlere Wirkleistung / Peak max. demand 4

FREQUENZ / FREQUENCY 4

LEISTUNGSFAKTOR / POWER FACTOR 4

BETRIEBSSTUNDENZÄHLER / RUN HOUR METER 4

ANZEIGE DISPLAY Hintergrundbeleuchtung / Backlit

IMPULS ENERGIE / PULSE ENERGY Impuls / Pulse 4

KOMMUNIKATIONCOMMUNICATION

RS485 4

RS232 RS485 + IF

M-Bus

Profibus

Ethernet RS485 + IF

ABMESSUNGEN DIMENSIONS 4 TE / 4 Module

IF = Externe Schnittstelle / external interface NT6

72 0

9- 2

015

13a

Ed.

pa

g.2/

8

Page 3: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

NT6

72 0

9- 2

015

13a

Ed.

pag

.3/8

ANZEIGE

Display : LCD-Display, 8-stellig

Ziffernhöhe: 6mm

Angezeigte Messgrössen : aufgeteilt in Menüs und Seiten

Seitenwahl: manuell, durch Drücken der Fronttaste Page

Parameter Rücksetzung: manuell, durch Drücken der Fronttaste Page

Seitenwahl und Parameterrückstellung auch bei plombiertem Zähler möglich

ANZEIGE

Gesamt Wirkenergie

Gesamt Blindenergie

Teil Wirkenergie

Teil Blindenergie

Max. Wirkleistungmittelwert

Wirkleistungmittelwert

Betriebsstundenzähler1

Spannungen, Stroms und Leistungen

Phasenstroms l1, l2, l3

Verkettete Spannungen L1-2, L2-3, L3-1

Wirkleistung

Blindleistung

Scheinleistung

Frenquenz und Leistungsfaktor1 Möglichkeit, den Betriebstunden-Reset bei Programmierung zu sperren

PROGRAMMIERUNG

Programmierung der Parameter: über 2 Fronttasten

Zugang zur Programmierung: Passwortgeschützt

Zugang Programmierung: bei plombierter Front ist die Programmierung nicht möglich

Speicherung der Daten und Parameter: nicht flüchtiger Speicher (ohne Batterie)

EINGANG

Netzwerk: Wechselstromnetz, Drehstromnetz 3-4-Leiter

Nennspannung dreiphasig: 400-415V und 100-115V

Arbeitsbereich: 210...264V und 90...140V

Nennspannung einphasig: 230-240V und 100-115V

Arbeitsbereich: 210...264V und 90...140V

Spannungswandlerübersetzung (kVT): 1...1500,0

z.B. VT 600/100V kVT = 6

für Direktanschluss, gilt kVT=1

Eigenverbrauch - Spannungspfad (max. Spannung): 4,5VA (1,85W) bei 440V

Nennfrequenz: 50-60Hz

Toleranz: 47...63Hz

Nennstrom, Ib: 1A + 5A

Maximalstrom., Imax: 6A

Startstrom: 20mA

Stromwandlerübersetzung (kCT): 1...9.999

z.B. TC 800/5A kCT = 160

für Direktanschluss, gilt kCT=1

DISPLAY

Display type: LCD, 8 digit

Digit height: 6mm

Measurement display: subdivided on menus and pages

Page scrolling: manual, by front push-button Page

Parameter reset: manual, by front push-button Page

Page scolling and parameter reset possible with sealed kWh meter

DISPLAY PAGES

Total active energy

Total reactive energy

Partial active energy

Partial reactive energy

Active power max. demand

Active power demand

Hour Meter1

Voltages, currents and powers

Phase currents l1, l2, l3

Linked voltages L1-2, L2-3, L3-1

Active power

Reactive power

Apparent power

Frequency and Power factor1 possibility to inhibit from programming the run hour meter resetting

PROGRAMMING

Parameters programming: front keyboard, 2 keys

Programming access: protected by password

Programming access: not possible with sealed kWh meter

Data and configuration parameters retention: non volatile memory (no battery)

INPUT

Network : Single-phase, three-phase 3-4 wire network

Reference three-phase voltage: 400-415V and 100-115V

Specified operating range: 210...264V and 90...140V

Reference single-phase voltage: 230-240V and 100-115V

Specified operating range: 210...264V and 90..140V

External VT ratio (kVT) : 1...1500,0

Ex. VT 600/100V kVT = 6

For direct connection, load kVT=1

Power consumption in voltage circuit (max. voltage): 4,5VA (1,85W) @ 440V 3-phase

Reference frequency: 50-60Hz

Tolerance: 47...63Hz

Basic current, Ib: 1A + 5A

Max.current, Imax: 6A

Starting current: 20mA

External CT ratio (kCT) : 1...9.999

Ex. CT 800/5A kCT = 160

For direct connection, load kCT=1

BESTELLNUMMER ORDERING

CODE

AUSGANGOUTPUT

SPANNUNG / VOLTAGE STROMCURRENT

FIRMWAREeinphasig / single-phase dreiphasig / three-phase

CE4DT14A2 Impulsausgangenergy pulses

230 / 240V 230(400V) / 240(415)V

1 / 5A 3

CE4DT12A2 100 / 115V 57,7(100) / 63,5(110)V

CE4DT14A4 Kommunikation RS485RS485 communication

230 / 240V 230(400V) / 240(415)V

CE4DT12A4 100 / 115V 57,7(100) / 63,5(110)V

CE4DT14A6 Impulsausgang + Kommunikation RS485

energy pulses + RS485 communication

230 / 240V 230(400V) / 240(415)V

CEADT12A6 100 / 115V 57,7(100) / 63,5(110)V

LEGENDE: = Programmierbare Parameter= Rücksetzbare Parameter

LEGEND:= Programmable Parameter= Reset Parameter

Page 4: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

Short-time overcurrent (EN/IEC 62053-21, EN/IEC 62053-23): 20Imax/0,5s

Power consumption in current circuit (max. current) : 0,3W for phase

Highest loadable ratio kVT x kCT = 5.000.000 (CT/1A) or 1.000.000 (CT/5A)

Current distortion factor according to EN/IEC 62053-21

Power factor

Specified operating range (EN/IEC 62053-21, EN/IEC 62053-23):

active cosϕ 0,5 ind...0,8 cap, reactive senϕ 0,5 ind...0,5 cap

AUXILIARY SUPPLY

Taken from measurement (selfsupplied phases L1-L2)

ENERGY

Maximum display: see table

Resolution: see table

Metering LED: 1imp/0,1Wh

Active energy accuracy (EN/IEC 62053-21): class 1

Reactive energy accuracy (EN/IEC 62053-23): class 2

Start-up time of the meter (EN/IEC 62053-21, EN/IEC 62053-23): < 5 seconds

POWER DEMAND

Quantity: active power

Calculation : average on the selected time interval

Averaging time period : 5 - 8 - 10 - 15 - 20 - 30 - 60 minutes

HOUR METER

Hour meter: working hours and minutes

Resolution: 7 digits (5 hours + 2 minutes)

Maximum display: 99.999h 59min

Count start: three-phase active power

Programmable value : 0,10..50% Pn

(three-phase active power, referred 400V 5A = 3464W)

Counter reset : keyboard-accessible or inhibited

OUTPUTS

ENERGY PULSES

Pulse output compatible with S0 EN/IEC 62053-31

Optorelay with potential-free SPST-NO contacts

Contact range: 110Vdc/ac – 50mA

Assignable energy : active or reactive energy

Pulse weight: 10Wh(varh) – 100Wh(varh) – 1kWh(kvarh) – 10kWh(kvarh -

100kWh(kvarh) - 1.000kWh(kvarh)

Pulse duration : 50 – 100 – 150 – 200 – 300 – 400 – 500ms

RS485 COMMUNICATION

Galvanically insulated from input an auxiliary supply

Standard: RS485 – 3 wire

Trasmission: asynchronous serial

Protocol: ModBus RTU

Address : 1...255

Bit number: 8

Stop bit: 1

Parity bit: none - even - odd

Baud rate: 4.800 – 9.600 - 19.200 bit/s

Required response time to request: ≤ 200ms

Meters that can be connected on the bus: 32 (up to 255 with RS485 repeater)

Highest distance from supervisor: 1200m

Überlast kurzzeitig (EN/IEC 62053-21, EN/IEC 62053-23): 20Imax/0,5s

Eigenverbrauch - Strompfad (max. Strom): 0,3W für Phase

Maximalwert kVT x kCT = 5.000.000 (CT/1A) o. 1.000.000 (CT/5A)

Stromverzerrungsfaktor gem. EN/IEC 62053-21

Leistungsfaktor

Arbeitsbereich (EN/IEC 62053-21, EN/IEC 62053-23):

aktiv cosϕ 0,5 ind...0,8 cap, reaktiv senϕ 0,5 ind...0,5 cap

HILFSSPANNUNG

Hilfsspannung aus Messkreis (selbstversorgend, Phasen L1-L2)

ENERGIE

Max. Anzeige: gem. Tabelle

Auflösung : gem. Tabelle

LED-Anzeige: 1imp/0,1Wh

Genauigkeit Wirkenergie (EN/IEC 62053-21): Klasse 1

Genauigkeit Blindenergie (EN/IEC 62053-23): Klasse 2

Ansprechzeit nach dem Einschalten (EN/IEC 62053-21, EN/IEC 62053-23): < 5 sec.

LEISTUNGSMITTELWERT

Messgrösse: Wirkleistung

Berechnung: Mittelwert uber eingestellte Zeitperiode

Integrationszeit: 5/8/10/15/20/30/60 Minuten

BETRIEBSSTUNDENZÄHLER

Betriebsstundenzähler: Stunden und Minuten

Auflösung: 7-stellig (5 Stunden + 2 Minuten)

Max. Anzeige : 99.999h 59min

Zählung Start: Wirkleistung 3-Phase

Programmierbare Werte: 0,10..50% Pn

Wirkleistung 3-Phase, gem. 400V 5A - 3464W)

Betriebsstundenzähler Reset: uber Tastatur zugänglich oder gesperrt

AUSGANG

ENERGIE PULSE

Pulsausgang kompatibel mit S0 EN/IEC 62053-31

Optorelais mit Schließerkontakt SPST-NO, potentialfrei

Kontaktlast: 110Vdc/ac – 50mA

zuweisbare Energie : Wirk- oder Blindenergie

Impulswertigkeit : 10Wh(varh) – 100Wh(varh) – 1kWh(kvarh) – 10kWh(kvarh

100kWh(kvarh) - 1.000kWh(kvarh)

Impulsdauer : 50 – 100 – 150 – 200 – 300 – 400 – 500ms

KOMMUNIKATION RS485

Galvanisch getrennt von Eingang und Hilfspannung

Standard: RS485 – 3 Leiter

Übertragung: seriell, asynchron

Protokoll: ModBus RTU

Adressen: 1...255

Bitanzahl: 8

Stopbit: 1

Paritätsbit: none - even- odd

Baudrate: 4.800 – 9.600 - 19.200 bit/s

Antwortzeit: ≤ 200msMax. Geräteanzahl im Netzwerk: 32 (bis zu 255 mit RS485 Repeater)Max. Buslänge:: 1200m

NT6

72 0

9- 2

015

13a

Ed.

pa

g.4/

8

kCT x kVT kCT x kVT

MAXIMALE ANZEIGEMAXIMUM DISPLAY

AUFLÖSUNGRESOLUTION

1...9,9 9 9 9 9 9 9 , 9 9 kWh / kvarh 10Wh / varh10...99,9 9 . 9 9 9 . 9 9 9 , 9 kWh / kvarh 100Wh / varh

100...999,9 9 9 . 9 9 9 . 9 9 9 kWh / kvarh 1kWh / kvarh1.000...9999,9 9 9 9 . 9 9 9 , 9 9 MWh / Mvarh 10kWh / kvarh

≥ 10.000 9 . 9 9 9 . 9 9 9 , 9 MWh / Mvarh 100kWh / kvarh

Page 5: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

Datenübertragung:Gesamt und Teil-WirkenergieGesamt und Teil-BlindenergieMax. mittlere LeistungMittlere LeistungPhasenstromVerkettete Spannung Wirk-, Blind, ScheinleistungFrequenzLeistungsfaktorBetriebsstundenzähler

KOMMUNIKATION ETHERNET (NT809)

Bei Verwendung der Mod.CE4DT14A4 - CE4DT12A4 - CE4DT14A6 -CE4DT12A6

(Kommunikation RS485) + IF2E (RS485/Ethernet) Kommunikations-Schnittstelle

KOMMUNIKATION RS232 (NT693)

Bei Verwendung der Mod. CE4DT14A4 - CE4DT12A4 - CE4DT14A6 - CE4DT12A6

(Kommunikation RS485) + IF2E (RS485/RS232) Kommunikations-Schnittstelle

ISOLATION (EN/IEC 62052-11, 62053-21)

Installationskategorie: III

Verschmutzungsgrad: 2

Isolationsspannung: 300V Phase-Neutral

Stoβspannungsfestigkeit 5kV 1,2/60ms

Prüfkreis : Spannungseingang, Stromeingang, Impulsausgang, Kommunikation

Prüfspannung 2,75kV R.M.S. 50Hz/1min

Prüfkreis : Spannungseingang, Stromeingang, Impulsausgang, Kommunikation

Prüfspannung 4kV R.M.S. 50Hz/1min

Prüfkreis : alle Kreise und Erde

ELEKTROMAGNETISCHE VERTRÄGLICHKEIT

Test gem. EN/IEC 62052-11

ARBEITSBEDINGUNGEN

Referenztemperatur: 23°C ± 2°C

Arbeitsbereich: -5...55°C

Grenztemperatur für Lagerung und Transport: -25...70°C

Tropenausführung

Max. Verlustleistung1: ≤ 2,8W1 zur thermischen Dimensionierung des Schaltschrankes

GEHÄUSE

Gehäuse: 4 TE nach DIN 43880

Plombierbare Front und Klemmenabdeckung

Anschluss: Schraubanschluss

Befestigung: schnappbar auf DIN-Hutschiene 35mm

Hutschienentyp: TH35-15 (EN60715)

Gehäusematerial: Polycarbonat, selbstverlöschend

Schutzart (EN60529): IP54 Front, IP20 Anschlüsse

Gewicht : 260 Gramm

SCHRAUBKLEMMEN

MESSEINGANG

Draht (starr): min. 0,05mm2 / max. 4mm2

Draht (flexibel): min. 0,05mm2 / max. 2,5mm2

Empfohlenes Drehmoment: 0,5Nm / max. 0,8Nm

AUSGANG

Draht (starr): min. 0,05mm2 / max. 4mm2

Draht (flexibel): min. 0,05mm2 / max. 2,5mm2

Empfohlenes Drehmoment: 0,5Nm/ max. 0,8Nm

Transferred measurement :

Total and partial active energy

Total and partial reactive energy

Max. power demand

Power demand

Phase current

Linked voltage

Active, reactive and apparent power

Frequency

Power factor

Hour meter

ETHERNET COMMUNICATION (NT809)

By using only mod. CE4DT14A4 - CE4DT12A4 - CE4DT14A6 - CE4DT12A6

(RS485 communication) + IF2E (RS485/Ethernet) communication interface

RS232 COMMUNICATION (NT693)

By using only mod. CE4DT14A4 - CE4DT12A4 - CE4DT14A6 - CE4DT12A6

(RS485 communication) + IF2E (RS485/RS232) communication interface

INSULATION (EN/IEC 62052-11, 62053-21)

Installation category: III

Pollution degree: 2

Insulation voltage rating: 300V Phase-earth

Impulse voltage test 5kV 1,2/60ms

Considered circuits: voltage input, current input, pulse output, communication

A.C voltage test 2,75kV r.m.s 50Hz/1min

Considered circuits: voltage input, current input, pulse output, communication

A.C voltage test 4kV r.m.s 50Hz/1min

Considered circuits: all circuits and earth

ELECTROMAGNETIC COMPATIBILITY

Test according to EN/IEC 62052-11

ENVIRONMENTAL CONDITIONS

Reference temperature: 23°C ± 2°C

Specified operating range: -5...55°C

Limit range fpr storage and transport: -25...70°C

Suitable for tropical dissipation

Max.power dissipation1: ≤ 2,8W1 For switchboard thermal calculation

HOUSING

Housing: 4 module DIN 43880

Sealability front frame and terminal blocks

Connections: screw terminals

Mounting: snap-on 35mm rail

Rail type: top hat TH35-15 (EN/IEC 60715)

Housing material: self-extinguishing policarbonate

Protection degree (EN60529): IP54 front frame, IP20 terminals

Weight: 260 grams

TERMINAL CAPACITY

MEASURE INPUT

Rigid cable: min.0,05mm2 / max. 4mm2

Flexible cable: min.0,05mm2 / max. 2,5mm2

Tightening torque advised: 0,5Nm / max. 0,8Nm

OUTPUT

Rigid cable: min.0,05mm2 / max. 4mm2

Flexible cable: min.0,05mm2 / max. 2,5mm2

Tightening torque advised: 0,5Nm / max. 0,8Nm

NT6

72 0

9- 2

015

13a

Ed.

pag

.5/8

Page 6: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

NT6

72 0

9- 2

015

13a

Ed.

pa

g.6/

8

71,2

89 45

44

65,6

ABMESSUNGEN DIMENSIONS

Gehäuse und Anschlussklemmen plombierbar

Sealed housing and sealable terminal block

POSITION ANSCHLUSSKLEMMEN TERMINAL POSITION

5 82 11 15 29

3 41 6 34 357 9 33

Page 7: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

ANSCHLUSSBILDER WIRING DIAGRAMS

2 5 8 111 3 6 94 7

S1

P1

I N P U T

a

A

b

BL

N LOADX

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 292 5 811

34 35

M-Bus

WechselstromnetzSingle-phase network

S 1000/2321N1E

2 5 8 111 4 7

S1

P1

I N P U T

LOAD

3 6 9

a

A

b

B

a

A

b

BL1

L2

L3 X

XX

2 5 8

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 3-Leiter gleich belastetThree-phase 3-wire network,balanced load

S 1000/2483-1E

2 5 8 1 3 6 94 7

S1

P1

S1

P1

I N P U T

LOAD

a

A

b

B

a

A

b

BL1

L2

L3

11

X

XX

2 5 8

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 3-Leiter ungleich belastet (ARON L1-L3)Three-phase 3-wire network,unbalanced load (ARON L1-L3)

S 1000/2463-2E (1-3)

2 5 8 111 3 6 94 7

S1

P1 S1

P1

I N P U T

LOAD

a

A

b

B

a

A

b

BL1

L2

L3 X

XX

2 5 8

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 3-Leiter ungleich belastet (ARON L2-L3)Three-phase 3-wire network,unbalanced load (ARON L2-L3)

S 1000/2473-2E (2-3)

2 5 8 111 4 7

S1

P1 S1

P1

I N P U T

LOAD

3 6 9

a

A

b

B

a

A

b

BL1

L2

L3 X

XX

2 5 8

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 3-Leiter ungleich belastet (ARON L1-L2)Three-phase 3-wire network,unbalanced load (ARON L1-L2)

S 1000/2453-2E (1-2)

NT6

72 0

9- 2

015

13a

Ed.

pag

.7/8

Page 8: ENERGIEZÄHLER ENERGY COUNTING ... - ime … · Static Meter Conto D4-Pt submetering applications for low, medium voltage networks (with limits indicated for CT and VT ratio) 4 module

NT6

72 0

9- 2

015

13a

Ed.

pa

g. 8

/8

X

XX

S1

P1 S1

P1

I N P U T

S1

P1

VOLTAGE CURRENT

a

A

b

B

a

A

b

BL1

L2

L3

LOAD

2 5 8

2 5 8 11 1 3 4 6 7 9

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 3-Leiter ungleich belastet Three-phase 3-wire network,unbalanced load

S 1000/2503-3E

S1

P1

I N P U T

VOLTAGE CURRENT

a

AL1

L2

L3

NLOAD

X

XX

X X X

2 5 8 11

2 5 8 11 1 3 4 6 7 9

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 4-Leiter gleich belastet Three-phase 4 -wire network,balanced load

S 1000/2493N1E

X

XX

S1

P1 S1

P1 S1

P1

a

AL1

L2

L3

NX X X LOAD

I N P U T

VOLTAGE CURRENT

2 5 8 11

2 5 8 11 1 3 4 6 7 9

O U T P U T

33 34 35

RS 485 Rx / Tx GND + –

15 29 34 35

M-Bus

Drehstromnetz, 4-Leiter gleich belastet Three-phase 4-wire network,balanced load

S 1000/2313N3E

NOTE: the wiring diagrams, show the device complete with pulse output and RS485

or M-Bus interface.

In case of versin without of these features, the corresponding terminals must not be

considered

BEMERKUNG!Die Anschlussbilder zeigen die Geräte mit Impulsausgang und KommunikationRS485 und M-Bus.Bei Bestellungen der Geräte ohne diese Ausgänge, sind diese Anschlüsse nichtbelegt

IME Messgeräte behält sich das Recht vor, die technischen Merkmale ohne Benachrichtigung zu ändern

www.ime-messgeraete.de

KONTAKT