erris court, saxilby enterprise park, saxilby, lincoln ... · roof light above to be installed in...
TRANSCRIPT
ERRIS COURT, SAXILBY ENTERPRISE PARK, SAXILBY, LINCOLN, LN1 2LR
Business units
100 sq m (1,076 sq ft) to 560 sq m (6,028 sq ft)
Under construction with completion due Summer 2020
Uniform Business Park environment
Excellent links to A57/A46/A1
FOR SALE / TO LET
LOCATION
The property is located on the popular Saxilby Enterprise Park just off the A57 close to Saxilby approximately 3 miles west of the A46 Lincoln Bypass and 5 miles from Lincoln City Centre. Saxilby is only 12 miles from the A1.
PROPERT Y
The proposed premises are to comprise 1 x 2-storey detached hybrid office/industrial building and 8 x terraced industrial units.
The hybrid office/industrial building will be finished with carpeted floors, painted plastered walls and suspended ceilings incorporating inset lighting in the offices together with clear workspace and a vehicular access door in the warehouse plus allocated staff/WC facilities.
The industrial units will provide clear workspace with staff/WC facilities and vehicular access doors.
There will be communal loading/circulation areas and allocated car parking.
The units are currently under construction and are due to be completed Summer 2020.
ACCOMMODATION
Architects drawings suggest that the accommodation will provide the following Gross Internal Floor Areas :
Hybrid 166 sq m (1,788 sq ft)Industrial 1 to 4 100 sq m (1,076 sq ft) eachIndustrial 5, 6 & 8 114 sq m (1,227 sq ft) eachIndustrial 7 218 sq m (2,347 sq ft)
TOWN AND COUNTRY PLANNING
We understand that planning consent has been granted for the proposed scheme, falling within Class B1 (Offices/Industrial) of the Town & Country Planning (Use Classes) Order 1987 (as amended). Interested parties are advised to make their own investigations to the Local Planning Authority.
SERVICES
We understand that mains supplies of water and electricity are to be made available and connected to the development. Interested parties are advised to make their own investigations to the utility service providers.
RATES
Charging Authority: West Lindsey District Council Description: To be assessed Rateable value: TBC UBR: 0.504 Period: 2019-2020
Multiplying the Rateable Value figure with the UBR multiplier gives the annual rates payable, excluding any transitional arrangements which may be applicable. For further information, please contact the Charging Authority.
TENURE
The premises are available To Let either individually or combined on Full Repairing and Insuring terms for a period of years to be agreed. Alternatively, the units may be available For Sale freehold.
PRICE/RENT
Hybrid £240,000 / £13,500 paxIndustrial 1 to 4 £124,000 / £7,000 paxIndustrial 5,6 & 8 £140,000 / £8,000 paxIndustrial 7 £245,000 / £13,500 pax
SERVICE CHARGE
A service charge will be levied to cover the upkeep, maintenance and repair of all common parts of the development.
VAT
VAT may be charged in addition to the rent/sale price at the prevailing rate.
LEGAL COSTS
Each party is to be responsible for their own legal costs incurred in documenting the transaction.
VIEWING: To view the premises and for any additional information please contact the sole agents.
Contact: Harry Hodgkinson T : 01522 544515 E : [email protected] Ref. 7298/2016/2019G
42770
8895170578895
7534
1101
1549
10001000
3610
1018
4
7535
1100
1549
1018
4
2200
6421 3610 1689 3610 1600 1100 6709 1100 1600 3610 1689
42770
1500
2200
2200
6421
1500 1500
2200
1500
100019621000 1960
Industrial Unit100sqm
Industrial Unit100sqm
Industrial Unit100sqm
Industrial Unit100sqm
AA
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
NOTE: Steel stanchions are located withinthe party wall. Please note that one hourfire integrity needs to be maintainedbetween the units, as does the air tightnessin respect of the air pressure test.
Double skin blockwork wall to betaken up to roof soffit and sealed toachieve 1hr fire protection betweenunits
Doc M packto beinstalled inall DIS WC
Doc M packto beinstalled inall DIS WC
Doc M packto beinstalled inall DIS WC
Doc M packto beinstalled inall DIS WC
EW001
EW002 EW003 EW006 EW007EW004 EW005
EW008
EW009EW010EW011EW012
Min. 1500 x1500mm level
landing at FFL infront of main
entrance
Main entrance door to havea 'level' approach from theparking area and a 'level'threshold with a min. clearopening width of 1000mm.(UPVC DOORS WILL NOTACHIEVE A CLEAROPENING OF 1000MM.)
RWP RWPRWPRWP
RWP RWPRWPRWPIC
SVP
IC
SVP
IC
SVP
IC
SVP
Surface water taken tosoakaway 5m from anybuilding. Below groundSW drainage to structuralengineer's details
Below ground FWdrainage system tostructural engineer'sdetails
12450
9405
4900
01
02
03
04
05
06
07
08
01
03
06
08
09
9405
4900 4750
12450
02
01
04
9405
4750
12450
4900
04
02
01
Tying in of inner block skin to ensure stability -to be confirmed by structural engineer
Wall Construction:Kingspan KS1000 RW Vertical TrapezoidalInsulated Wall Panel with core thickness of80mm to achieve min. U-value of 0.26W/m2Kinstalled to specialist manufacturers details onKingspan mutibeam cladding rails andmulticleats to structural engineer's details.100mm medium density block work betweensteel columns to a height of 2475mm from FFL.
Kingspan Highline Type gutter or similar
Kingspan Multibeam purlin rails or similarapproved to structural engineer's details.
Eaves detail in accordance with specilaistmanufacturer's details
Steel Portal frame to designed by structuralengineer and is to conform to the collapsemechanism under Constrado
115mm thick Kingspan KS1000RW / LPCBinsulated roof panel to provide a U-value of0.18W/m2K installed to specialistmanufacturer's details
Foundations to structural engineer's details
Ground bearing slab to structural engineer'sdetails
The completed floor construction to achieve aminimum U-value of 0.20W/m2K.
Rainwater gutters connected to Colour coatedaluminium rainwater downpipes connected atground to 100mm dia. Upvc undergrounddrainage
Kingspan KS1000 Day-Lite TrapezoidalPolycarbonate roof lights installed tospecialist manufacturers details.
Wall panel drip detail to specialistmanufacturer's details
Slab edge detail TBC following structuralengineer's foundation and slab details
Door head detail beyond as per Block 3sections
DisWC
Roof to disabled toilet to be 18mm ply boardon 97x47mm C16 timbers at 400mm centres.NOTE: roof to be kept clear. No items to bestored on the roof of the disabled WC.
Lintel above WC to be confirmed by structuralengineer
2475
4545
2493
30°
Movement joints to structural engineer'sdetails
4900
Dark grey engineering bricks below DPC level
Material Specification
04
03
02
01Kingspan Trapezoidal Vertical Insulated Cladding orsimilar approved - Colour: Cosmic Grey
Upvc or PPC aluminium doors coloured - RAL7032 (Pebble Grey)
Kingspan Trapezoidal Vertical Insulated Claddingor similar approved - Colour: Pale Eucalypt
Indicates Blockwork walls
Residual Risk Information: Beware ofincreased manual handling risk - 2person to lift where required ormechanical device to be used wherepossible.
Indicates Facing brickwork -Refer to Proposed Elevationsfor details
LEGEND:
Mechanical ventilation toprovide 3 air changes perhour at 15 litres/ sec. tooutside air in ceiling void.
SD Optical smoke detector
RWP
IC
SVP Soil Vent Pipe
Rainwater pipe
FW Inspection Chamber
Indicative surface water drainage tostructural engineer's details
Indicative foul water drainage tostructural engineer's details
4920 Levels to be checked on site.
Half hour fire door*
05
Steel rainwater gutters. Colour: Cosmic Grey06
Roller Shutter - colour: dark grey
07 Frameless Glass Canopies
08Kingspan Day-Lite Trapezoidal Polycarbonaterooflights
09 Steel Personell Door - colour: dark grey
Project
Client
Drawing Title
Scale Date
Project No. Drawing No. Revision
ã
Studio 2, Deepdale Enterprise Park,Deepdale Lane,Nettleham, LincolnLN2 2LL
Drawn by
Registered in England 08206944 - Reg. Office : Studio 2, Deepdale Enterprise Park,Deepdale Lane, Nettleham Lincoln, LN2 2LL
DetailsDate IssuedRevision
Client Logo
NOTES
1. No dimensions are to be scaled from thisdrawing.
2. All dimensions are to be checked on siteprior to construction
Checked by
TEW
01522 [email protected]
BUILDING REGULATIONS
Plans, Sections and ElevationsBlock 2
Lincs Civil Engineering
794
AJS
Unit 5, Saxilby Enterprise ParkOffices and Industrial Units
A00
Varies at A1 August 2018
(20) 002
AMK
----------DD.MM.YY---
SCALE 1 : 100
0m 2m 4m 6m 10m8m
100mm80mm60mm40mm0mm 10mm 20mm
Proposed Ground Floor Plan 1:100@A1
Proposed East Elevation 1:100@A1
Proposed West Elevation 1:100@A1
Proposed North Elevation 1:100@A1 Proposed South Elevation 1:100@A1
Proposed Section AA 1:50@A1
N
SCALE 1 : 50
0m 1m 2m 3m 5m4m
100mm80mm60mm40mm0mm 10mm 20mm
DRAFT
Industrial Unit114sqm
Industrial Unit218sqm
Industrial Unit114sqm
Industrial Unit114sqm
Existing Industrial Unit
Min. 1500 x1500mm level
landing at FFL infront of main
entrance
AA
B B
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
Main entrance door tohave a 'level' approachfrom the parking areaand a 'level' thresholdwith a min. clear openingwidth of 1000mm.(UPVC DOORS WILLNOT ACHIEVE ACLEAR OPENING OF1000MM.)
Main entrance door tohave a 'level' approachfrom the parking areaand a 'level' thresholdwith a min. clear openingwidth of 1000mm.(UPVC DOORS WILLNOT ACHIEVE ACLEAR OPENING OF1000MM.)
Main entrance door tohave a 'level' approachfrom the parking areaand a 'level' thresholdwith a min. clear openingwidth of 1000mm.(UPVC DOORS WILLNOT ACHIEVE ACLEAR OPENING OF1000MM.)
EW002
EW001 EW003 EW004
EW005
EW008
EW006
EW007
EW009
EW010
EW011EW012EW013
ID001 ID002 ID003
ID004Doc M pack to beinstalled in all DIS WC
Dis.W.C.
Dis.W.C.
SD SD
SD
SD
NOTE: Steel stanchionsare located within theparty wall. Please notethat one hour fire integrityneeds to be maintainedbetween the units, asdoes the air tightness inrespect of the airpressure test.
NOTE: Steel stanchionsare located within theparty wall. Please notethat one hour fire integrityneeds to be maintainedbetween the units, asdoes the air tightness inrespect of the airpressure test.
NOTE: Steel stanchions are locatedwithin the party wall. Please note thatone hour fire integrity needs to bemaintained between the units, asdoes the air tightness in respect of theair pressure test.
Please note that one hour fireintegrity needs to be maintainedbetween the units, as does the airtightness in respect of the airpressure test.
Movement joints inmasonry to structuralengineer's details
Double skin blockwork wallto be taken up to roof soffitand sealed to achieve 1hrfire protection between units
RWP
RWP
RWP
RWP
RWP
RWP
RWP
Surface water taken tosoakaway 5m from anybuilding. Below groundSW drainage to structuralengineer's details
ACO linear drains at thresholds to levelaccess doors and roller shutters
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
Doc M packto beinstalled inall DIS WC
Dis.W.C.
Dis.W.C.
20595
1104 3610 1476 1100 4112 3610 1476 1100 3008
3040
0
8746
950
1400
950
1835
4
325951003 950 9347 950 18391 950 1003
1018
1100
1475
3610
1602
3610
1475
1100
3409
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
KingspanDay-Lite
Trapezoidalpolycarbonate
roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Kingspan Day-LiteTrapezoidal
polycarbonate roof lightabove
Doc M packto beinstalled inall DIS WC
Doc M packto beinstalled inall DIS WC
ACO linear drains at thresholds to levelaccess doors and roller shutters
1200
0
IC
SVP
IC
SVP
IC
SVP
IC
SVP
Below ground FWdrainage system tostructural engineer'sdetails
Double skin blockwork wallto be taken up to roof soffitand sealed to achieve 1hrfire protection between units
Double skin blockwork wallto be taken up to roof soffitand sealed to achieve 1hrfire protection between units
7020 7020
8370 8370
4920
9425
11895
Provide canopy aboveabove main entrance doorsfor weather protection if theentrance is a manual nonpowered entrance door.
Provide canopy aboveabove main entrance doorsfor weather protection if theentrance is a manual nonpowered entrance door.
01
02
03
04
05
06
07
08
Existing warehouseretained
7020 7020 7020
4920
9425
11895
01
03
06
08
09
7020 7020
4920
9425
11895
01
03
09
06
08
Dark grey engineering bricks below DPC level
Material Specification
05
04
03
02
01
Steel rainwater gutters. Colour: Cosmic Grey06
Roller Shutter - colour: dark grey
07
Kingspan Trapezoidal Vertical Insulated Cladding orsimilar approved - Colour: Cosmic Grey
Upvc or PPC aluminium doors (to client'srequirements coloured - RAL 7032 (PebbleGrey)
Kingspan Trapezoidal Vertical Insulated Claddingor similar approved - Colour: Pale Eucalypt
Frameless Glass Canopies
08Kingspan Day-Lite Trapezoidal PolycarbonateRooflight
09 Steel Personell Door - colour: dark grey
A00
Project
Client
Drawing Title
Scale Date
Project No. Drawing No. Revision
ã
Studio 2, Deepdale Enterprise Park,Deepdale Lane,Nettleham, LincolnLN2 2LL
Drawn by
Registered in England 08206944 - Reg. Office : Studio 2, Deepdale Enterprise Park,Deepdale Lane, Nettleham Lincoln, LN2 2LL
DetailsDate IssuedRevision
Client Logo
NOTES
1. No dimensions are to be scaled from thisdrawing.
2. All dimensions are to be checked on siteprior to construction
Checked by
TEW
01522 [email protected]
BUILDING REGULATIONS
Proposed Plans and ElevationsBlock 3
Lincs Civil Engineering
794
AJS
Unit 5, Saxilby Enterprise ParkOffices and Industrial Units
A00
1:100 at A1 August 2018
(20) 003
AMK
------------ -------------------------
Elevation 01 (West) - 1:100
Elevation 02 (South) - 1:100
Elevation 03 (East) - 1:100
SCALE 1 : 100
0m 2m 4m 6m 10m8m
100mm80mm60mm40mm0mm 10mm 20mm
Proposed Floor Plan - 1:100DRAFT
N
Office 1:35.7 sq.m.
Under-Stair Store
Double Height Storage:51.8 sq.m.
Dis.W.C.
1.
2.
3.
4.
5.
6. Office 2: 35.7 sq.m.
W.C.
19.
18.
17.
16.
15.
14.
13.12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1. up
Kingspan Day-LiteTrapezoidal
polycarbonate rooflight above
Kingspan Day-LiteTrapezoidal
polycarbonate rooflight above
up
ID001
ID002
ID003
ID004
ID005
ID006
EW001EW002EW003
EW007
EW008EW009EW010
EW011
EW012
EW013
10003
1340 1023 1340 1023 2128 1135 2015
1225
3
1340
1023
1340
1023
1903
1023
4603
1115 3610 5277
150010015006203
4400
100
1256
140
5756
300
300
100
2100
100
2200
10003
1340 1023 1340 1023 2240 1023 2015
1225
3
1340
1023
1340
1023
7528
1115 3610 5277
1499
4158
140
5889
5889
31006200
Polyester Powder CoatedAluminium Windows/doors,colour: RAL 7032 (PebbleGrey). Windows andexternal doors to achieve anarea weighted average of1.6W/m2K
A A
B B
EW004
EW005
EW006
A A
B B
C
C
140mm thick blockwall up to roof soffitTBC by structuralengineer
SD
SVP
*IC
Floorspanover Doc M pack to be
installed in all DISWC
SD
SD
SD
*
**
SVP
AAV
IC
RWP
RWP
RWP
RWP
All steel beams at ground floor level to be encasedin 1 layer of 15mm Gyproc wallboard or 1 layer12.5mm Gyproc fireline or to receive fire resistantpaint finish to achieve 30 min fire resistance
All steel beams at ground floor level to be encased in 1 layer of15mm Gyproc wallboard or 1 layer 12.5mm Gyproc fireline or toreceive fire resistant paint finish to achieve 30 min fire resistance
Movement joints inmasonry to structuralengineer's details
Stainless Steel ACO drain todoor threshold
Main entrance door to have a 'level' approachfrom the parking area and a 'level' threshold witha min. clear opening width of 1000mm.(UPVC DOORS WILL NOT ACHIEVE A CLEAROPENING OF 1000MM.)
C
C
Kingspan Day-LiteTrapezoidal
polycarbonate rooflight above
Kingspan Day-LiteTrapezoidal
polycarbonate rooflight above
Surface water taken tosoakaway 5m from anybuilding. Below groundSW drainage to structuralengineer's details
Below ground FWdrainage system tostructural engineer'sdetails
12962
10935
5100
01
10
03
04
11
06
01
08
12962
10735
5100
01
10
03
04
11
06
01
08
Provide canopy above above main entrancedoors for weather protection if the entrance is
a manual non powered entrance door.
02
01
10
03
04
1107
06
01
10
03
05
06
11
Dark grey engineering bricks below DPC level
Material Specification
04
03
02
01Kingspan Trapezoidal Vertical Insulated Cladding orsimilar approved - Colour: Cosmic Grey
Upvc or PPC aluminium doors coloured - RAL7032 (Pebble Grey)
Kingspan Trapezoidal Vertical Insulated Claddingor similar approved - Colour: Pale Eucalypt
05
Steel rainwater gutters. Colour: Cosmic Grey06
Roller Shutter - colour: dark grey
07 Frameless Glass Canopies
08Kingspan Day-Lite Trapezoidal Polycarbonaterooflights
09 Steel Personell Door - colour: dark grey
30mm SoundDeck Overlay Acoustic Floor Boards to acheive 19DBacoustic insulation, on 22mm tongue and groove chipboard decking, onEcojoists - V2-14 375mm (timber size = 47x97) @ 400mm centres toacheive max. span of 5800mm to specialist details. Joist hangers to beused where Ecojoists meet 1 Hour Fire Walls to protected stair enclosure
Tying in of inner block skin to beadvised by structural engineer
Metal stud walls - 60 I 70 Gypwall Classic Metal Studs at 400mm centreswith 1No. layer of Gyproc wall board on both sides to achieve 30 minutesfire resistance. Stud partitions to be installed at a maximum height of4600mm.
Upper Wall Construction:Kingspan KS1000 RW Vertical Trapezoidal InsulatedWall Panel with core thickness of 80mm to achievemin. U-value of 0.26W/m2K installed to specialistmanufacturers details on Kingspan mutibeamcladding rails and multicleats to structural engineer'sdetails. 100mm medium density block work betweensteel columns up to first floor level.
80mm site applied LPCB certified PIR insulationboard any gaps filled with fire rated canisterinsulation
Wall panel soffit detail in accordance withspecialist manufacturer's details
Window head and cill detail in accordancewith specialist manufacturer's details
UPVC or Polyester Powder Coated AluminiumWindows/doors, colour: RAL 7032 (Pebble Grey).Windows and external doors to achieve an area weightedaverage of 1.6W/m2K
Timber cillsWindow head and cill detail in accordancewith specialist manufacturer's details
Kingspan Highline Type gutter or similar
Kingspan Multibeam purlin rails or similar approved to structural engineer's details.
Eaves detail to specialist manufacturers details
Steel Portal frame to designed by structuralengineer and is to conform to the collapsemechanism under Constrado
Suspended ceiling
Half hour fire rated compartment floor formed with 1No. layer15mm Gyproc fireline board mechanically fixed to underside offloor joists. Penetrations to be fitted with intumescent collars
115mm thick Kingspan KS1000RW / LPCB insulatedroof panel or similar to provide a U-value of0.18W/m2K
Soldier course
100mm blockwork wall to structural engineer's details
Foundations to structural engineer's details
Ground bearing slab to structural engineer's details
The completed floor construction toachieve a minimum U-value of 0.20W/m2K.
Cavity Tray
Timber Stair - total rise of 3225mm (TBC on site), min.250mm individual going, 169.73mm individual rise (TBC onsite - all stair risers to be equal. Stair risers to be a min.150mm and max. 170mm). Min 2000mm headroommeasured vertically above pitch line. Min 1200mm widthbetween walls. Handrail 900 - 1000mm vertically above pitchline to both sides of the stair. Max. pitch to be 42°. Handrail tolanding areas to be 1100mm above finished floor level. Anyopenings in staircase or balustrade to be restricted so that a100mm dia. sphere cannot pass through the opening. Allbalusters to be set vertical to prevent climbing.
1812
low
er c
eilin
g
Office 2
Office 1
WC
DisWC
5955
150
3225
floo
r to
floor
2325
top
of s
oldi
er c
ours
e
1800
303
First floor internal skin of external walls to be softwood or MF studs or block work supported on steelbeam or off ground floor internal skin Or off Firstfloor construction, to be confirmed by structuralengineers.
Steel Portal frame to designed bystructural engineer and is toconform to the collapse mechanismunder Constrado
Steel frame at ground floor ceilinglevel or lower to be encased orpainted with intumescent paint toachieve 30 min fire resistance.
Rainwater gutters connected to Colour coated aluminiumrainwater downpipes connected at ground to 100mm dia.Upvc underground drainage
Lower Wall Construction:Outer skin of facing buff brickwork. 100mm cavity fully filled with Dritherm cavity slab insulation (min. thermal conductivityof 0.032 W/mK): 100mm Plasmor Stranlite lightweight block inner skin (min. thermal conductivity of 0.46 W/mK). Stainlesssteel double triangle type wall ties as described in BS1243:1978 at 450mm vertical and 750mm staggered horizontalcentres and 225mm vertical centres at bonded jambs. The whole wall construction to provide a U-value of 0.26W/m2K
5100
Walls taken to underside ofroof covering andfire-stopped with 12 HourRockwool fire barrier system
Tying in of inner block skin to beadvised by structural engineer
Lower Wall Construction:Outer skin of facing buff brickwork. 100mm cavity fullyfilled with Dritherm cavity slab insulation (min. thermalconductivity of 0.032 W/mK): 100mm Plasmor Stranlitelightweight block inner skin (min. thermal conductivity of0.46 W/mK). Stainless steel double triangle type wallties as described in BS1243:1978 at 450mm verticaland 750mm staggered horizontal centres and 225mmvertical centres at bonded jambs. The whole wallconstruction to provide a U-value of 0.26W/m2K
Upper Wall Construction:Kingspan KS1000 RW VerticalTrapezoidal Insulated Wall Panelwith core thickness of 80mm toachieve min. U-value of0.26W/m2K installed to specialistmanufacturers details on Kingspanmutibeam cladding rails andmulticleats to structural engineer'sdetails. 100mm medium densityblock work between steel columnsup to first floor level.
80mm site applied LPCB certifiedPIR insulation board any gapsfilled with fire rated canisterinsulation
Wall panel soffit detail inaccordance with specilaistmanufacturer's details
Steel Portal frame to designed bystructural engineer and is toconform to the collapse mechanismunder Constrado
Soldier course
Foundations to structuralengineer's details
Ground bearing slab to structuralengineer's details
The completed floor constructionto achieve a minimum U-value of0.20W/m2K.
Cavity Tray
Window head and cilldetail in accordance withspecilaist manufacturer'sdetails
UPVC or Polyester PowderCoated AluminiumWindows/doors, colour: RAL7032 (Pebble Grey).Windows and external doorsto achieve an area weightedaverage of 1.6W/m2K
Window head and cilldetail in accordance withspecilaist manufacturer'sdetails
UPVC or Polyester PowderCoated AluminiumWindows/doors, colour:RAL 7032 (Pebble Grey).Windows and externaldoors to achieve an areaweighted average of1.6W/m2K
Walls taken to underside of roofcovering and fire-stopped with 12Hour Rockwool fire barrier system
Area of Kingspan Multibeampurlin rails or similar approved tostructural engineer's details.
115mm thick Kingspan KS1000RW/ LPCB insulated roof panel toprovide a U-value of 0.18W/m2K
Sealed verge flashing in accordancewith specilaist manufacturer's details
Double Height Storage
Dis.W.C.
Under-StairStore
30mm SoundDeck Overlay Acoustic Floor Boards to acheive19DB acoustic insulation, on 22mm tongue and groovechipboard decking, on Ecojoists - V2-14 375mm (timber size =47x97) @ 400mm centres to acheive max. span of 5800mm tospecialist details. Joist hangers to be used where Ecojoistsmeet 1 Hour Fire Walls to protected stair enclosure
Half hour fire ratedcompartment floor formedwith 1No. layer 15mmGyproc fireline boardmechanically fixed tounderside of floor joists.Penetrations to be fittedwith intumescent collars
100mm blockwork wall tostructural engineer's details
Timber Stair - total rise of3225mm (TBC on site), min.250mm individual going,169.73mm individual rise (TBCon site - all stair risers to beequal. Stair risers to be a min.150mm and max. 170mm). Min2000mm headroom measuredvertically above pitch line. Min1200mm width between walls.Handrail 900 - 1000mm verticallyabove pitch line to both sides ofthe stair. Max. pitch to be 42°.Handrail to landing areas to be1100mm above finished floorlevel. Any openings in staircaseor balustrade to be restricted sothat a 100mm dia. sphere cannotpass through the opening. Allbalusters to be set vertical toprevent climbing.
Steel frame at ground floor ceiling level or lowerto be encased or painted with intumescent paintto achieve 30 min fire resistance.
First floor internal skin of external walls to be soft woodor MF studs or block work supported on steel beam oroff ground floor internal skin Or off First floorconstruction, to be confirmed by structural engineers.
2100
3225
303
1800
Provide canopy above abovemain entrance doors forweather protection if theentrance is a manual nonpowered entrance door.
5100
2475
Lintels to structuralengineer's details
Lower Wall Construction:Outer skin of facing buff brickwork. 100mm cavity fullyfilled with Dritherm cavity slab insulation (min. thermalconductivity of 0.032 W/mK): 100mm Plasmor Stranlitelightweight block inner skin (min. thermal conductivity of0.46 W/mK). Stainless steel double triangle type wallties as described in BS1243:1978 at 450mm verticaland 750mm staggered horizontal centres and 225mmvertical centres at bonded jambs. The whole wallconstruction to provide a U-value of 0.26W/m2K
5100
Tying in of inner block skin to beadvised by structural engineer
Upper Wall Construction:Kingspan KS1000 RW Vertical Trapezoidal InsulatedWall Panel with core thickness of 80mm to achievemin. U-value of 0.26W/m2K installed to specialistmanufacturers details on Kingspan mutibeamcladding rails and multicleats to structural engineer'sdetails. 100mm medium density block work betweensteel columns up to first floor level.
80mm site applied LPCB certified PIR insulationboard any gaps filled with fire rated canisterinsulation
Wall panel soffit detail in accordance withKingspan drawing RWWVt15012.
Kingspan Highline Type gutter or similar
Kingspan Multibeam purlin rails or similar approved to structural engineer's details.
Eaves detail in accordance with specialist manufacturer's details
Steel Portal frame to designed by structuralengineer and is to conform to the collapsemechanism under Constrado
115mm thick Kingspan KS1000RW / LPCB insulatedroof panel to provide a U-value of 0.18W/m2K
Soldier course
Foundations to structural engineer's details
Ground bearing slab to structural engineer's details
The completed floor construction toachieve a minimum U-value of 0.20W/m2K.
Cavity Tray
Rainwater gutters connected to Colour coated aluminiumrainwater downpipes connected at ground to 100mm dia.Upvc underground drainage
Indicates Blockwork walls
Residual Risk Information: Beware ofincreased manual handling risk - 2person to lift where required ormechanical device to be used wherepossible.
Indicates Facing brickwork -Refer to Proposed Elevationsfor details
LEGEND:
Mechanical ventilation toprovide 3 air changes perhour at 15 litres/ sec. tooutside air in ceiling void.
SD Optical smoke detector
RWP
IC
SVP Soil Vent Pipe
Rainwater pipe
FW Inspection Chamber
Indicative surface water drainage tostructural engineer's details
Indicative foul water drainage tostructural engineer's details
4920 Levels to be checked on site.
AAV Air Admittance Valve
Project
Client
Drawing Title
Scale Date
Project No. Drawing No. Revision
ã
Studio 2, Deepdale Enterprise Park,Deepdale Lane,Nettleham, LincolnLN2 2LL
Drawn by
Registered in England 08206944 - Reg. Office : Studio 2, Deepdale Enterprise Park,Deepdale Lane, Nettleham Lincoln, LN2 2LL
DetailsDate IssuedRevision
Client Logo
NOTES
1. No dimensions are to be scaled from thisdrawing.
2. All dimensions are to be checked on siteprior to construction
Checked by
TEW
01522 [email protected]
BUILDING REGULATIONS
Proposed Plans, Elevations and SectionsBlock 1
Lincs Civil Engineering
794
AJS
Unit 5, Saxilby Enterprise ParkOffices and Industrial Units
A00
1:100 at A1 October 2018
(20) 001
AMK
------------- DD.MM.YY
SCALE 1 : 100
0m 2m 4m 6m 10m8m
100mm80mm60mm40mm0mm 10mm 20mm
Proposed Ground Floor Plan(1:100)
Section A-A(1:50)
Section C-C(1:50)
Proposed First Floor Plan(1:100)
Proposed West Elevation(1:100)
Proposed North Elevation(1:100)
Proposed East Elevation(1:100)
Proposed South Elevation(1:100)
Section B-B(1:50)
DRAFTSCALE 1 : 50
0m 1m 2m 3m 5m4m
100mm80mm60mm40mm0mm 10mm 20mm
N
The Money Laundering, Terrorist Financing and Transfer of Funds (Information on the Payer) Regulations 2017 require estate agents and solicitors to formally identify parties to a transaction. Interested parties will therefore be required to provide proof of identity and address, normally a photocard driving licence or passport and recent utility bill. BANKS LONG & CO for themselves and for the vendors or lessors of this property whose agents they give notice that (i) the particulars are set out as a general outline only for the guidance of intending purchasers or lessees and do not constitute part of an offer or contract (ii) all descriptions, dimensions, references to condition and necessary permissions for use and occupation and other details are given in good faith and are believed to be correct but any intending purchasers or tenants should not rely on them as statements or representations of fact but must satisfy themselves by inspection or otherwise as to the correctness of each of them (iii) no person in the employment of BANKS LONG & CO has any authority to make or give any representation or warranty whatever in relation to this property.