FIRE ZONE BY NATIONAL BUILDING
CODE OF INDIAPART 4 - FIRE AND
LIFE SAFETYBY
NAYANA DEVAN
![Page 2: Fire zone by national building code of india 2005](https://reader036.vdocuments.net/reader036/viewer/2022082415/58f9b7381a28ab851f8b4593/html5/thumbnails/2.jpg)
INTRODUCTION
1. based on the fire hazard inherent in the buildings and strutures according to the occupancy , city or an area can be demarcated into different zones called “fire zone”.
![Page 3: Fire zone by national building code of india 2005](https://reader036.vdocuments.net/reader036/viewer/2022082415/58f9b7381a28ab851f8b4593/html5/thumbnails/3.jpg)
NUMBER AND DESIGNATIONS OF FIRE ZONES number of fire zones in a city depends on1. excisting layout
2. types of building construction
3. classification of excisting building by occupancy
4. excpected future development of the city
In large cities - 3 zones necessary
In small cities - 1 or 2 necessary
![Page 4: Fire zone by national building code of india 2005](https://reader036.vdocuments.net/reader036/viewer/2022082415/58f9b7381a28ab851f8b4593/html5/thumbnails/4.jpg)
ZONE 1 area having,
residential buildings (group A)
educational buildings (group B)
institutional buildings (group C)
assembly buildings (group D)
small business (sub division E 1)
retail merchantile (group F)
or areas which are under development for such industries
![Page 5: Fire zone by national building code of india 2005](https://reader036.vdocuments.net/reader036/viewer/2022082415/58f9b7381a28ab851f8b4593/html5/thumbnails/5.jpg)
ZONE 2 these shall comprise:
Business (E1-E5)
industrial buildings (subdivision g1 and G2)
or areas under development for such occupancies
![Page 6: Fire zone by national building code of india 2005](https://reader036.vdocuments.net/reader036/viewer/2022082415/58f9b7381a28ab851f8b4593/html5/thumbnails/6.jpg)
ZONE 3 these shall comprize areas having
high hazardous industries(subdivision G3)
storage buildings (group H)
buildings for hazardous use(group J)
or areas under development for such occupancies
![Page 7: Fire zone by national building code of india 2005](https://reader036.vdocuments.net/reader036/viewer/2022082415/58f9b7381a28ab851f8b4593/html5/thumbnails/7.jpg)
restriction on type of construction building erected in Zone 1 shall conform to Type 1,2,3,or 4
building erected in Zone 2 shall conform to Type 1,2, or 3
building erected in Zone 3 shall conform to Type 1 or 2