german national committee of icid (gecid)

18
Institut für Agrartechnologie und Biosystemte Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter, Dr. Heinz Sourell, Hans-Heinrich Thörmann, Federal Research Institute for Rural Areas, Forestry and Fisheries, Germany Institute of Agricultural Technology and Biosystems Engineering 27 June 2012, Adelaide German National Committee of ICID (GECID)

Upload: kaemon

Post on 13-Jan-2016

35 views

Category:

Documents


0 download

DESCRIPTION

German National Committee of ICID (GECID). - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: German National Committee of ICID (GECID)

Institut für Agrartechnologie und Biosystemtechnik

Possibilities of using the drip irrigation laterals on centre pivot irrigation

machines

Jano Anter, Dr. Heinz Sourell, Hans-Heinrich Thörmann,

Federal Research Institute for Rural Areas, Forestry and Fisheries, GermanyInstitute of Agricultural Technology and Biosystems Engineering

27 June 2012, Adelaide

German National Committee of ICID (GECID)

Page 2: German National Committee of ICID (GECID)

2Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Page 3: German National Committee of ICID (GECID)

3Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Contents

• Irrigation in Germany

• Advantages & disadvantages of drip irrigation and center pivot

• Steps to mobile drip irrigation

• Technical aspects

• Costs analysis

• Summary

Page 4: German National Committee of ICID (GECID)

4Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Irrigation in Germany

• 3% of the agricultural land are irrigated in Germany

• Humid climate, dry periods, sandy soils

• Cultures worth of irrigation: i.e. Potatos, Sugar beets

• Use of modern irrigation techniques

• The techniques are developed in terms of claims by farmers:- Water distrubtion - Intensity of labour - Water-efficient - Energy consumption

Page 5: German National Committee of ICID (GECID)

5Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Water distribution-systems

Page 6: German National Committee of ICID (GECID)

6Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Advantages & disadvantages of drip irrigation

+High water use efficiencyLow water lossesLow energy requirementsPossibility of chemigation

-High total costsHigh labour requirements for the assembly and disassembly

Page 7: German National Committee of ICID (GECID)

7Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Advantages & disadvantages of center pivot with sprinkler

+Full-Automatic machine managementLow labour requirementsModerate capital requirementSimple to use

-Water lossesWind drift High energy requirements

Page 8: German National Committee of ICID (GECID)

8Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Operating costs

Center Pivot

Drip Irrigation

Page 9: German National Committee of ICID (GECID)

9Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Steps to mobile drip irrigation

Drip irrigation Center pivot

Mobile Drip Irrigation

Page 10: German National Committee of ICID (GECID)

10Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Installation of mobile drip irrigation by centre pivot

Page 11: German National Committee of ICID (GECID)

11Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Field experiments

The Center pivot consisting 9 towers

The total lenght of this pivot machine was approximately 428 m

The total irrigated area of about 57 ha

Drip tubes distance: 0.75 m

In the field investigations, two operating pressures were used at the inlet of the drip tubes (50 kPa and 100 kPa)

Page 12: German National Committee of ICID (GECID)

12Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Emitters

Mobile drip irrigation needs emitters that have:

• High discharge (8 l/h & 10 l/h)• Low distance between them (0.15 m)

To reduce the lenght of drip tubes and the numbers of emitters

• High emission uniformity (over 95 %)• Low coefficient of variation (lower than 5 %)

To enhance irrigation water distrubtion on the soil surface

Page 13: German National Committee of ICID (GECID)

13Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Length of drip tubes at two pressures

- The lenght of the drip tubes is dependent upon the emitter discharge and the distance from the pivot point

- The lenght of the drip tubes increases as the distance from the pivot point grows

- For the stability of the centre pivot irrigator, additional friction force is

important

- The friction force at 50 kPa were higher than the friction force at 100 kPa (2470 N & 1743 N at the ninth tower)

- This force is suitable for the electric motors which are mounted on each tower.

Page 14: German National Committee of ICID (GECID)

14Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Length of drip tubes at two pressures

0

3

6

9

12

15

18

21

0 50 100 150 200 250 300 350 400 450

Lateral length of center pivot, m

Leng

th o

f dr

ip t

ubes

, m

50 kPa

100 kPa

Page 15: German National Committee of ICID (GECID)

15Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Costs analysis (Capital requirement)

Item Unit Center Pivot sprinkler

Stationary drip irrigation

Mobile drip irrigation

Irrigated area ha 57.55 57.55 57.55Water required m3/ha 200 64 160No. of irrigations per season 5 12.5 5Total water required m3/ha per season 1000 800 800Energy requirement kWh/(ha*a) 360 128 208Total working time h/ha/season 0.5 9.975 0.75

Capital requirement (Initial cost)

€ 60,572 132,20056,225 * 15,487**

71,722 (Total)* = Pivot machine without sprinklers** = Only drip tubes, emitters and regulators

Page 16: German National Committee of ICID (GECID)

16Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Costs analysis (Operating costs)

276209

906

590

158 127

0100200300400500600700800900

1000

SDI MDI CPSIrrigation system

Tot

al y

early

cos

ts,

Eur

o/ha

One season

Two seasons

Page 17: German National Committee of ICID (GECID)

17Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Summary

• High water efficiency / Water saving up to 20%

• Energy conservation up to 40%

• The total costs of MDI were close to the total costs of a CP

• For the same area we need only 1,6 % respectively of the tubes that would needed for a SDI

• Filtering of the water can become important

• Further experiments with other plants is necessary

Page 18: German National Committee of ICID (GECID)

18Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Many thanks for your attention!