handheld shower - enwareresource.enware.com.au/installation instructions/sp272_sp273_sgr023... ·...
TRANSCRIPT
Call 1300 369 273www.enware.com.auEnware Australia Pty Limited 9 Endeavour Rd Caringbah NSW 2229 Australia Ph: +61 2 8556 4000 Fax: +61 2 8556 4055
I00032_Dec 17
SP272 Series
SGR023 Series
SP273 Series
SGR027 SeriesSGR028 SeriesSGR029 Series
Installation and Maintenance Instructions
HANDHELD SHOWER
www.enware.com.au Call 1300 369 27 3
IMPORTANT NOTE: Where required, the installer must install an appropriate backflow prevention device before a shower hose according to the cross-connection hazard rating. (E.g. in situations where a shower hose is installed over a bath, the shower outlet is installed at a low height, or a shower hose is long enough to reach the floor, bidet or a WC pan.)
The shower may not be suitable for use with gravity-fed water heaters, low pressure supply networks, instantaneous water heaters, tempering valves and thermostatic mixing valves. (AS3662-2013). For use with potable water only.
Inlet Connection Female ½” BSP (150mm)
Working Pressure Range 150 - 500 kPa*
Maximum Working Pressure (AS/NZS3500)* 500 kPa*
Recommended Pressure 200-500 kPa*
Maximum Water Temperature 70°C^
Operating Temperature Range 10-70°C
Flow Rate 8.5 l/minute ( 3 Star WELS)
technical data
The morestars the morewater efficient
8.5 litres per minute
WATER RATINGwww.waterrating.gov.au
AS/NZS 3662C of C 40129Global-Mark
*Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
Reference should also be made to the Australasian Health facility Guidelines (AHFG), ABCB and Local Government regulations when considering the choice of, and the installation of these products.
The following clauses must be observed for a compliant installation and correct operation of Enware tapware:
^ All heated water installations for sanitary fixtures used primarily for personal hygiene purposes shall deliver heated water at a temperature not exceeding:
a) 45°C for healthcare and aged care buildings, early childhood centres, primary and secondary schools and nursing homes, or similar facilities for the aged, the sick, children, or people with disabilities; and
b) 50°C for all other situations (Laundries and kitchen sinks are not required to have heated water at a maximum of 50°C) This product must be installed and commissioned by a qualified plumber. For use with potable water only.
NOTE: Enware Australia advises: 1. Due to ongoing Research and Development, specifications may change without notice. 2. Component specifications may change on some export models.
WATER SERVICESPlumbing Code of Australia: Part B1 Cold Water ServicesAS / NZS 3500.1-2015 Water Services;• Section 1.6(a) Facilities for people with Disabilities• Section 3.3.2 Pressure at outlets (min 50kPa)• Section 3.3.4 Maximum pressure within buildings (500kPa static)• Section 3.4 Velocity Requirement (Max 3.0m/s)• Section 16 Testing and Commissioning; Flushing, Hydrostatic testing, cleaning and disinfection of water services.
HEATED WATER SERVICESPlumbing Code of Australia: Plumbing Code of Australia: Part B2 Heated Water ServicesAS / NZS 3500.4-2015 Heated Water Services;• Section 1.9 Water Temperature 1.9.1 Storage Temperature 1.9.2 Sanitary fixtures delivery temperature 1.9.3 Acceptable solutions for control of delivery temperatures• Section 10 Heated Water Services for People with Disabilities• Section 11 Testing and Commissioning
installation compliance
4 Call 1300 369 273 www.enware.com.au
NOTE These are guides only and do not overrule prescribed rail positions by appropriately qualified consultants. AS1428.1-2009 compliance requirements refer to the standards document.
700mm +/- 5
580mm - 600mm
800mm - 810mmto top of rail
800mm - 810mm
1700mm - 1900mm
Standard Installation Guide
AS1428.1 Guide to Inlet Height and Handrail Position
set out installation guidelines
www.enware.com.au Call 1300 369 27 5
950
75
900
32
110 (REF)
1.5m LONG HOSE
SINGLE FUNCTION HANDPIECE
1/2" BSP
25
75 50
NOTE: Dimensional drawings for product illustrating purpose only. For set-out compliance refer to AS1428.1-2009 and 2010 amendments Design for Access and Mobility.
NOTE Dimensional drawings for product illustrating purposes only. For set-out compliance refer to AS1428.1-2009 and 2010 amendments Design for Access and Mobility.
1.5m LONG HOSE
HOOK ROTATABLE
WATER INLET1/2" BSP
SINGLE FUNCTION HANDPIECE
225
(REF
)
215
(REF
)
65
45
110 (REF)
SP272, SP272C & SP272CS
SP273, SP273C & SP273CS
Note for SP273 the slider is different. Refer to pg 7.
technical drawings
6 Call 1300 369 273 www.enware.com.au
T-Rail SGR027T, SGR028TL & SGR029TR
SGR023
SP273C & CS
1/2" BSP
25
75 50
900
70
32
110 (REF)
SINGLE FUNCTION HANDPIECE
1.5m HOSE
110
1/2" BSP
32 72
25
1.5m HOSE
350 700
5 0
110
0
8 0
700 495 205
90°
700 495 205
90°
SGR027T SERIES SGR028TL SERIES SGR029TR SERIES
* Note for SGR027TC and SGR027TCS Models shower slider is different. Refer to pg 8.
* Note for SGR023C and SGR023CS models the shower slider is different. Refer to pg 8.
technical drawings
NOTE Dimensional drawings for product illustrating purposes only. For set-out compliance refer to AS1428.1-2009 and 2010 amendments Design for Access and Mobility.
www.enware.com.au Call 1300 369 27 7
2
5
3
4
1
5
3
2
6
7
4
11
3
5
2
4
7
6
# Description1 SHOWER HAND PIECE2 1.5M HOSE3 WALL HOOK4 END CAP5 FLOW CONTROLLER
# Description1 SHOWER HAND PIECE2 1.5M HOSE3 HAND SHOWER HOLDER/SLIDER4 END CAP5 FLOW CONTROLLER6 GRAB RAIL7 WALL ELBOW
# Description1 GRABRAIL2 WALL ELBOW3 END CAP4 FLOW CONTROLLER5 SHOWER HAND PIECE6 1.5M HOSE7 HAND SHOWER HOLDER/SLIDER
SP272, SP272C & SP272CS SP273 SP273C & SP273CS
components
8 Call 1300 369 273 www.enware.com.au
2
7
6
1
5
4
3
5
7
2
41
3
6
4
3
5
1
2
# Description1 SHOWER HAND PIECE2 1.5M HOSE3 HAND SHOWER HOLDER/SLIDER4 FLOW CONTROLLER5 GRAB RAIL6 WALL ELBOW7 END CAP
# Description1 GRAB RAIL2 WALL ELBOW3 END CAP4 FLOW CONTROLLER5 SHOWER HAND PIECE6 1.5M HOSE7 HAND SHOWER HOLDER/SLIDER
# Description1 SHOWER HAND PIECE2 1.5M HOSE3 HAND SHOWER HOLDER/SLIDER
(3A OR 3B)4 GRAB RAIL
LEFT CENTRED RIGHTSGR028 SGR027 SGR029
5 WALL ELBOW
SGR023 SGR023C & SGR023CS SGR027, SGR027C & SGR027CSSGR028, SGR028C & SGR028CSSGR029, SGR029C & SGR029CS
3B
3A
components
www.enware.com.au Call 1300 369 27 9
1/2” BSP Male tail 10mm outside the wall
Outlet Point face downward
Rubber Washer
Flow Controller
SP272, SP272C & SP272CS
Turn off water supply
1. Please ensure a male 1/2” BSP tail (not supplied) is installed and protrudes at a minimum of 10mm outside the finished wall. See IMAGE 1. Apply thread tape onto the tail.
2. Install the wall hook to the 1/2” BSP tail. Make sure the hook sits flat against the wall, and the outlet point of the wall hook is facing downward. See IMAGE 2
3. Connect hose to wall outlet. Place rubber washer in end of hose and hand tighten into wall connection.
4. Place flow controller into the base of the hand piece. See IMAGE 3. Check direction of the flow controller. See IMAGE 4. Place rubber washer on flow controller and hand tighten hose to the base of the hand piece.
5. Place the hand piece onto the hook. Turn on water supply and check for operation, flow and water leaks around all connections.
IMAGE 1
IMAGE 2
IMAGE 3
IMAGE 4
Water Out
Water In
assembly and installation handheld shower with hook (no rail)
10 Call 1300 369 273 www.enware.com.au
Rail Installation for SP273 Series
1. Place the wall bar vertically against the wall at the desired position. Mark the position of the top flange on the wall by tracing the outline of the flanges.
TIP: Use a level for vertical alignment.
2. Remove the top base by removing the grub screw on the flange via an allen key. See IMAGE 5.
3. Centre the base in the top outline marked on the wall and mark the positions of the holes in the base flange on the wall. See IMAGE 6.
4. Drill holes to suit hole patterns on the base. Secure the base with suitable countersink screws (not supplied) See IMAGE 7.
Make sure the top of the screw sits flush with the top of the base.
TIP: Place rail back on top base and mark bottom base outline. Use level for vertical alignment.
5. Remove the bottom base flange. Repeat Steps 3 and 4 for bottom base.
6. Install the wall bar onto the bases via the flanges and reinsert grub screws See IMAGE 8.
IMAGE 8
Base
Countersink Screws
IMAGE 7
Rail
Base
Flange
IMAGE 5
Grub ScrewNOTEThe rail base has Ø5mm holes and screw are NOT supplied.
1
2
IMAGE 6
assembly and installation heavy duty wall bar
www.enware.com.au Call 1300 369 27 11
SGR023 Series
1. Carefully slide the top covering flange away from the base.
2. Place the rail in position against the wall. TIP: Use a level for vertical alignment.
3. Mark the top base hole position onto the wall. See IMAGE 9 NOTE Mark single hole only.
4. Remove the rail. Drill hole in the wall in the position marked.
5. Attached the rail using a single top screw loose enough to be able to rotate rail. See IMAGE 10
6. Carefully remove the bottom covering flange for access to the bottom base.
7. Using a level, plumb the rail vertically and mark the bottom base hole positions.
8. Remove rail from the wall completely and drill holes for top and bottom bases of rail.
9. Screw rail to wall using 6 fixing screw as supplied. NOTE: if supplied screws are unsuitable for wall materials use appropriate fixing screws.
10. Carefully reattach covering flanges. See IMAGE 11.
IMAGE 9
Screw
IMAGE 10
IMAGE 11
assembly and installation grab rail
12 Call 1300 369 273 www.enware.com.au
OUTLET FOR SP273 AND SGR023 SERIES
1. Turn off Water Supply
2. Install the wall elbow onto the 1/2” BSP connection using suitable plumbers tape. Make sure the outlet point is sitting squarely in the downward position. See IMAGE 14
SHOWERHEAD FOR SP273 AND SGR023 SERIES
1. Place flow controller into the base of the hand held shower. See IMAGE 15 Check direction of the flow controller. Place rubber washer on flow controller and hand tighten hose to base of hand held piece.
2. Place the hand piece onto the hook. Turn on water supply and check for operation, flow and water leaks around all connections.
3. Place the handpiece onto the shower head holder. Turn on water supply and check for operation, flow and water leaks around all connections
Connect wall elbow onto 1/2” BSP Tail
SLIDER INSTALLATION FOR CHROME (C & CS) MODELS
Disassemble the back casing of the holder and remove the plastic bush. Place it onto the rail. Place the front & back casing of the holder onto the rail. Use the screw supplied to lock the back casing in place. SEE IMAGE 12
SLIDER INSTALLATION FOR WHITE MODELS
Remove the side covers from the holder, disassemble the screws and remove the side body. Place the holder onto the rail. Reassemble the side body, screws and the side covers. SEE IMAGE 13
Note: Slider is supplied attached
IMAGE 14
IMAGE 15
assembly and installation slider
handheld shower to suit wall bar or grab rail
Front casing
Plastic Bush
Back casing
IMAGE 12
IMAGE 13
Side Covers
ScrewsSide Body
Outlet Point face downward
Flow Controller
Hand Piece
Thick Rubber Washer
Thin Rubber Washer
www.enware.com.au Call 1300 369 27 13
DESCRIPTION ORDER CODE
Pressalit Care Hand Shower Holder/Slider - White For other colours contact your Enware Representative
EP-RT600000
Wall Hook with Inlet for Hand Held Shower SP278
Wall Elbow with Dual Check SP267
Hand Held Shower Holder/Slider - Chrome SP276
Hand Held Shower - Head Only - White SP277
Hand Held Shower - Head Only - Chrome SP277C
Hand Held Shower - Replacement Kit for Grab Rail - White (includes 1.5m white hose and SP277)
SP274
Hand Held Shower - Replacement Kit for Grab Rail - Chrome(includes 1.5m smooth chrome hose and SP277C)
SP274C
Hand Held Shower - Replacement Kit for Grab Rail - Chrome with Spiral Hose (includes 1.5m chrome spiral hose and SP277C)
SP274CS
Grab Rail - SP273 Series 672296
Grab Rail Only Stainless Steel 300mm SGR010
Grab Rail Only Stainless Steel 600mm SGR012
Grab Rail Only Stainless Steel 900mm SGR013
Inverted T-Shape Centered Grab Rail Only - Stainless Steel SGR017T
Inverted T-Shape Left Hand Grab Rail Only - Stainless Steel SGR018TL
Inverted T-Shape Right Hand Grab Rail Only - Stainless Steel SGR019TR
Shower Hose * * Where required, the installer must install an appropriate backflow pre-vention device before a shower hose according to the cross-connection hazard rating. (E.g. in situations where a shower hose is installed over a bath, the shower outlet is installed at a low height, or a shower hose is long enough to reachthe floor, bidet or a WC pan.)
SP280 - White 1.5mSP281 - White 2.0mSP282 - Smooth Chrome 1.5mSP283 - Smooth Chrome 2.0mSP284 - Spiral Chrome - 1.5m
Flow Controller 9 Lpm MK040 (Specify Flow Rate)
2
5
3
4
1
spare parts
14 Call 1300 369 273 www.enware.com.au
Enware Product should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive. Epoxy coated surfaces should only be cleaned with a cloth and clear water or mild detergent. Use of unsuitable cleaning agents may damage the surface. Any damage caused in this way will not be covered by warranty.
For further help contact our Service Department on 1300 369 273 or +61 2 8556 4000
PROBLEM CAUSE RECTIFICATION
No water flowing to the shower hand-piece
Water supply turned off Turn on water supply
Flow controller installed incorrectly See installation instruction on page 10 to install the flow controller correctly
Debris is fouling the flow controller Clean or replace the flow controller
Water is leaking between the hose and the shower handpiece, or between hose and wall connection
Washer is worn Replace washer
Hose connection is damaged Replace hose
Water is leaking on the wall elbow or the wall hook body
Not enough thread tapes were applied to the 1/2” BSP tail
Unscrew the wall elbow and apply more thread tape
troubleshooting
care & maintenance
www.enware.com.au Call 1300 369 27 15
product warranty for Australia Effective 1 September 2014
Enware Australia Pty Limited (ACN 003 988 314) (“we” or “us”) warrants that this product (also referred to as “our goods”) will be free from all defects in materials and workmanship for 24 months* from the date of purchase. Our liability under this warranty is limited at our option to the repair or replacement of the defective product or part, the cost of repair of the defective product or part or the supply of an equivalent product or part, in each case if we are satisfied the loss or damage was due to a defect in the materials or workmanship of the product or part. All products must be installed in accordance with the manufacturer’s instructions, the PCA, and AS/NZS3500 including any other applicable regulatory requirements.
exceptionsThis warranty does not apply in respect of any damage or loss due to or arising from:
a) Failure by you or any other person to follow any instructions for use (including instructions and directions relating to the handling, storage, installation, fitting, connection, adjustment or repair of the product) published or provided by us;
b) Failure by you or any other person responsible for the fitting, installation or other work on the product to follow or conform to applicable laws, standards and codes (including the AS/NZ 3500 set of Standards, all applicable State and Territory Plumbing Codes, the Plumbing Code of Australia and directions and requirements of local and other statutory authorities); or
c) Any act or circumstance beyond our control including faulty installation or connection, accident, abnormal use, acts of God, damage to buildings, other structures or infrastructure and loss or damage during product transit or transportation.
making a claimTo make a claim under this warranty you must notify us in writing within 7 days of any alleged defect in the product coming to your attention and provide us with proof of your purchase of the product and completed the Online Product Service and Warranty Form available on website www.enware.com.au. All notifications and accompanying forms must be sent to us marked for the attention of the Enware Australia Pty Limited, 9 Endeavour Road, Caringbah NSW 2229. We can also be contacted by telephone (1300 369 273) or by email ([email protected]).
Your costs in making a claim under this warranty, including all freight, collection and delivery costs, are to be borne and paid by you. We also reserve the right at our cost to inspect any alleged defect in the product wherever it is located or installed or on our premises.
*Conditional warranty: Jumper Valve Tapware - 2 Years: 1 year parts and labour on the complete assembly then a further 1 year parts only warranty is applicable
Ceramic Disc Cartridge Tapware - 10 Years: 10 Year ceramic disc cartridges – parts only; 1 Year parts and labour on complete assembly
Outlets - 1 Year parts and labour on the complete assembly
other conditionsExcept as provided or referred to in this document, we accept no other or further liability for any damages or loss (including indirect, consequential or economic loss) and whether arising in contract, tort or otherwise. Any benefits available to you under this warranty are in addition to any non-excludable rights or remedies you may have under applicable legislation, including as a “consumer” under the Australian Consumer Law. To that extent you need to be aware that: Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.