heartrec holter ecg 72hours..more
TRANSCRIPT
Smallest in Size, Perfect in Performance
In addition to excellent technical
characteristics, HeartRec was elaborately
designed to ensure the best possible
Specifications ▲ Channels: Two Work Modes
12-lead / 3-Channel Switchable by Changing Patient Cable
10-Wire Cable: 12-Lead: I, II, III, aVR, aVL, aVF, V1 - V6 5-
Wire or 7-Wire: Standard 3 Channels ▲ Program able Recording:
Time: 24h-72h, up to 7 days for 3ch Sampling Rate: 128—1024/ch/s up to
10,000/ch/s Resolution: 12-16 bits
Independent Pace Maker Channel ▲ LCD Display:
Real Time ECG View Instruction Programming
Multi-Language Selectable ▲ High Quality Recording:
Frequency Response:
0.05~60Hz CMMR: >80dB
Input Impedance: >5MΩ ▲ Double Work Modes in Data Access:
Removable SD Card: 512MB/1GB/
2GB USB connector ▲ Low Power Consuption:
One AAA Battery: up to 7 days for 3-Channel ▲ Compact Size & Light Weight:
72mm×53mm×16mm (2.8"×2.0"×0.63")
48g (1.7oz.), battery not included
Meditech Equipment Co., Ltd (Meditech Group)
Address: Nanjing Road No.100, Qingdao, Shandong Province, P. R. China
China Tel: 86-532-85832673 85820563
Fax: 86-532-85832155
Email: [email protected] [email protected]
USA Tel: +01 2399355088
UK Tel: +44 2081233737
Web: www.meditech.com.cn
experience for the patient and the user.
表格 1
Heartrec an advanced HOLTER developing history. Sophisticated software system
and elaborate HOLTER recorder, Heartrec as an integrate system combines both 3-
channel and 12-lead recording and analyzing in one, meets all high-end performance and
fiscal responsibility.
Automatic template Classification:
Color-enhanced, beat-by-beat Arrhythmiagraph
display showing heart rate and detected Normal, VE,
SVE, and Unknown beats. Quickly access any
displayed beat and view it
On a 12-lead ECG strip. Sophisticated Templates Editor: Three advanced tools based on beats superimposition
DEMIX RR-HIST BIRDVIEW
Tools for 12-Lead ST-T Analysis
With the finest tools to measure and analyze ST segment
episodes, the system is easy-using in myocardial ischemia
positioning depending on either event or entire period.
depression, elevation and slope, and combining ST-T trend,
superimposition, and scanning com partition to edit any ST
ST Segment Setting 12-Lead ST Trend with ECG Scanning 12-Lead T Trend with ECG Scanning
Pacemaker Analysis Comprehensive pacemaker report.
The feature includes algorithms for a wide range of
pacer types including WI, AAI and DDD, etc., produces a
VVI AAI DDD Modes VVI AAI DDD Trend VVI AAI DDD Statistics Table
Automatic Atrial Fibrillation Analysis with Assistant Tools
Fibrillation Analysis Fibrillation Trend Obstructive Sleep Apnea Syndrome
Analysis (Option)
Heart Rate Variability (HRV): With time-domain, frequency-domain and nonlinear analysis Either 5min, 1 hour or 24 hours available
HRV HISH HRV Frequency Heart Rate Turbulence (VE Chaos, HRT) Analysis (Option)
T wave Alterance Analysis (Option) : A Significant Index for Analyzing Malignant Arrhythmia and Sudden Cardiac Death
QT dispersion Bird View (Option) Including VCG and VLP for Rest ECG