hsa6500 gsm alarm · 3 fit wall plugs and secure the pir base with the screws provided. 4 fit the...

32
HSA6500 GSM alarm Installation · Programming · Operating Keep this manual safe for reference and future maintenance Introduction Contents Thank you for choosing the Yale Wireless Alarm System. This simple to install system has been designed with the user in mind. All the components are self contained and no connections are needed between the units. There is no need to damage the home decor, lift carpets or run cables. You can install up to 20 devices in this system. As well as extra door/window contacts, PIRs and smoke detectors, you can add keyfob remote controls and keypads for added control convenience. There is no need to wire into the mains supply or seek the services of a qualified electrician. The control unit is powered by a plug top supply and all other components are powered by battery (all batteries included). Batteries will operate for 2 years or more before they need changing. Regular testing and battery changes (when notified by the system) will ensure reliability and peace of mind. The security detectors, control panel and external siren are ‘tamper’ protected. Any unauthorised tampering with these items will result in an alarm. This feature can be turned off by the user when a battery change is required. Display extreme caution when using ladders or steps, please follow manufacturer’s instructions. Be careful when using hand and power tools and follow the manufacturer’s guidelines when using them. Take care that the correct tools are used. Wear goggles or protective clothing where required. The external Siren is extremely loud, please ensure you replace the cover and retreat to a safe distance before testing. The dialling/SMS facilities must only be used with persons who have consented to being contacted by the system. The system is not to be used to make 999 emergency calls directly. Yale do not hold responsibility for any actions taken by emergency services for incorrect use of the dialling/SMS facility. Special Notes on Compatibility: This alarm system is NOT compatible with SmartHome Alarm and Easy Fit alarm accessories. Please note the prefix “HSA” on the front of the model number to indicate compatibility. Information and illustrations are subject to change within this document. Yale reserves the right to alter the specification and product design at anytime without notice. Yale® is a registered trademark. © 2015 ASSA ABLOY. All rights reserved. Contents 1 Location planning 2 2 Unpack all the parts 4 3 First Time Easy Install 6 4 Mounting alarm devices 8 5 Control Panel Menu System in Detail 11 6 Using the System 17 Adding and using Accessories 20 Changing the batteries 22 Troubleshooting 24 Sensor response table 27 Specifications 28 Remote SMS control 30 Recommended Installation Sequence We recommend you follow the simple install sequence, headings numbered 1-6.

Upload: others

Post on 09-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

HSA6500 GSM alarm Installation · Programming · OperatingKeep this manual safe for reference and future maintenance

Introduction ContentsThank you for choosing the Yale Wireless Alarm System. This simple to install system has been designed with the user in mind.

All the components are self contained and no connections are needed between the units. There is no need to damage the home decor, lift carpets or run cables.

You can install up to 20 devices in this system. As well as extra door/window contacts, PIRs and smoke detectors, you can add keyfob remote controls and keypads for added control convenience. There is no need to wire into the mains supply or seek the services of a qualified electrician. The control unit is powered by a plug top supply and all other components are powered by battery (all batteries included).Batteries will operate for 2 years or more before they need changing. Regular testing and battery changes (when notified by the system) will ensure reliability and peace of mind.

The security detectors, control panel and external siren are ‘tamper’ protected. Any unauthorised tampering with these items will result in an alarm. This feature can be turned off by the user when a battery change is required.

Display extreme caution when using ladders or steps, please follow manufacturer’s instructions.Be careful when using hand and power tools and follow the manufacturer’s guidelines when using them. Take care that the correct tools are used. Wear goggles or protective clothing where required.The external Siren is extremely loud, please ensure you replace the cover and retreat to a safe distance before testing.

The dialling/SMS facilities must only be used with persons who have consented to being contacted by the system.The system is not to be used to make 999 emergency calls directly. Yale do not hold responsibility for any actions taken by emergency services for incorrect use of the dialling/SMS facility.

Special Notes on Compatibility:

This alarm system is NOT compatible with SmartHome Alarm and Easy Fit alarm accessories. Please note the prefix “HSA” on the front of the model number to indicate compatibility. Information and illustrations are subject to change within this

document. Yale reserves the right to alter the specification and product design at anytime without notice. Yale® is a registered trademark. © 2015 ASSA ABLOY. All rights reserved.

Contents

1 Location planning 2

2 Unpack all the parts 4

3 First Time Easy Install 6

4 Mounting alarm devices 8

5 Control Panel Menu System in Detail 11

6 Using the System 17

Adding and using Accessories 20

Changing the batteries 22

Troubleshooting 24

Sensor response table 27

Specifications 28

Remote SMS control 30

Recommended Installation Sequence

We recommend you follow the simple install sequence, headings numbered 1-6.

Page 2: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

2

Y a le

aleY

aleY

Text Display

Text Display

aleY R

1 2 3

6547 8 9

0

Location planning

Home and Away Mode Planning

The home arming mode allows the premises to be part armed so that no one can get inside without warning the occupier, yet the person already inside the house can move freely without triggering the alarm. For example the downstairs of a house can be armed while upstairs can be disarmed allowing the user to go to bed without causing an alarm. If this feature is to be used, then it should be planned now, before installation.Decide what areas can be occupied when in home arming mode, the sensors for these areas should be ignored using the “Home-arm set” option (see page 11); and the sensors activated on the path to access the control unit should be set to either Entry or Away Entry as explained in Chapter 5.

Operating Range

All devices must be within 30 metres of the control unit and must not be mounted on or near large metal objects. Avoid obvious sources of electrical interference such as fridges and microwave ovens.

Tamper Switches

When mounting devices ensure that any tamper switches close fully. On uneven surfaces it may be necessary to place packing behind the switch for reliable operation.

Extend The System

Extend the system in the future to increase your security or as your needs change.For example, add extra PIR detectors and extra door/window contacts.

Choosing Location

To minimise interference, avoid locating devices close to metal framework, glass, electrical appliances (especially wireless devices) and electric cables. Please note that the present of high density material (metal, glass etc) in the transmission path will significantly reduce the wireless transmission range.

1Work out the best places to locate the devices for maximum protection. Having chosen the locations do not mount at this stage.

Keypad remote control accessory

When used as second keypad, it is ideal in bedrooms or at the top of a stairwell so the ground floor can be armed when going to bed for the night. Or, at a side or back door for alternative entry.•Mountatchestheightforeaseofuse•Designedforindooruseonly•Keypadshouldbeaccessiblefromaprotected

entry/exit point•Ensurethatthekeypadisnotvisiblefromthe

outside of the premises.

PIR movement detector

•Mountinapositionsuchthatanintruderwouldnormally move across the PIRs field of view.

•Heightshouldbebetween1.9and2metresabove floor level.

•Locationinacornerwillensurewiderroomcoverage.

•DonotmountthePIRwhereitsfieldofviewwillbe obstructed e.g. by curtains, ornaments etc.

•Donotpointdirectlyatsourcesofheate.g.firesor boilers, and do not position directly above radiators.

•AvoidmountingthePIRdirectlyfacingawindow.

•DonotpointthePIRatadoorprotectedbyadoor/window contact.

Help button accessory

The help button provides extra protection for you and your family. When help is needed the button can activate your alarm immediately - even when the system is disarmed.

•Mountonflatwallsurface•Designedforindooruseonly•Outofreachofchildren•Hiddenfromviewwhileeasilyaccessible.

Page 3: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

3

Y a le

aleY

aleY

Text Display

Text Display

aleY R

1 2 3

6547 8 9

0

Keyfob remote control accessory

Can be used inside or outside the property and can be kept on your keyring.

Smoke detector

•Mountinthemiddleoftheceilingatthetopofa stairwell, or on the centre of hallway ceilings where smoke would most likely be detected.

•Donotmountincornersorabovecookingappliances and heaters.

•Installadditionaldetectorsiftherearecloseddoors preventing smoke from reaching detectors.

Door/Window contact

Select a door that will be the main point of entry and exit, usually your front door.•Mountashighaspossible•DonotaimaPIRatthisdoororwindow

PIR movement detector

•Mountinapositionsuchthatanintruderwouldnormally move across the PIRs field of view.

•Heightshouldbebetween1.9and2metresabove floor level.

•Locationinacornerwillensurewiderroomcoverage.

•DonotmountthePIRwhereitsfieldofviewwillbe obstructed e.g. by curtains, ornaments etc.

•Donotpointdirectlyatsourcesofheate.g.firesor boilers, and do not position directly above radiators.

•AvoidmountingthePIRdirectlyfacingawindow.

•DonotpointthePIRatadoorprotectedbyadoor/window contact.

Control unit

•Ensureitishiddenfromviewwhileaccessible.•Accesstomainssocket.

Siren

Choose a position on an external wall where the siren would be most prominent. Mount as high as possible, out of easy reach.

Page 4: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

4

Unpack all the parts

Control unit

Unpack the kit content on a table. Remove the mounting plate (if fitted) from the control unit by sliding plate downwards. A power adaptor is supplied that plugs into the main wall socket and control unit. Do not plug in at this stage, this will be done at Section 3.

•Inadditiontotheadapter,thereisarechargeablebattery inside the control unit that serves as a backup in case of a power failure. A fully charged battery can provide backup power for a period of 10 hours. It takes approximately 72 hours to fully charge the battery. The control unit is equipped with a backlit LCD display and keypad for easy operation in the dark. To conserve backup battery duration the backlights will be switched off during mains power failure.

•Removethe“Simcard&Powerswitch”coverandswitch the internal battery to “on”.

•InsertastandardsizeGSMsimcard(notprovided), and replace the back cover. Please ensure the sim card is not pin protected.

2Siren

WARNINGThe siren is very loud, be prepared! Take care not to activate the siren tamper switch unnecessarily.

1 The siren comes in two shapes, rectangle or round depending on the kit purchased. Remove the cover by unscrewing the single screw located on the lid.

2 Power switch to ON position.

PIR movement detectors

1 Pull out the plastic pull tab on the back of the PIR. This will activate the batteries.

SirenMicrophone

Power LED

Fault LED

Home Arm

Numeric keys

Disarm

Arm

Text Display

DownBackspace/Return OK

Up

PlateSIM CARD & POWER SWITCH

Cover screwLearn/Test

Button

StatusLED

Page 5: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

5

Door/window contacts

1 Pull out the battery saver tab on the side to activate the battery.

Keyfob remote control accessory

1 Open the battery compartment using a coin by turning cover in the direction of the big arrow so the cover small arrow is next to round dot.

2 Insert CR2032 battery and replace cover.

Smoke detector accessory

1 Remove the cover and insert three AA batteries

2 The Smoke detector will now enter into self-calibration mode for 15-20 minutes. It will resume normal operation after this period.

Help button accessory

Remove the cover by loosening the fixing screw and insert the CR2032 battery (supplied) as shown (1). Please ensure you observe battery polarity.

Door/window contacts

1 Remove the cover of each door/window contactby loosening the fixing screw.

2 Insert two AAA batteries into each detector asshown. The indicator LED will flash briefly.

7

Keypad remote control

Remove the cover and insert the 3 AAA alkalinebatteries as shown. The ‘Tx’ LED will flash brieflywhile components initialise.

Please note, the Home button on the operatingpanel and the jumper switch inside (do not move)have no function on this model.

Smoke detector accessory

Remove the cover and insert the four AAAbatteries as shown.

Keyfob remote control accessory

Slide off the battery cover, insert the23A/MN21 battery as shown, and replacebattery cover. Switch to ‘on’.

Help button accessory

Remove the cover by loosening the fixingscrew and insert the 12V battery (supplied) asshown. Please ensure you observe batterypolarity.

Tamperswitch

Jumperswitch

Tamperswitch

Jumperswitch

Magnet

Extension terminals

Learn/Test button

Learn/Testbutton

On/Off switch

Keypad remote control accessory

1 Pull out the plastic battery saver tab at the back of the remote keypad. This will activate the batteries.

/

Learn/TestButton

LED

aleY

1

Panic/Learn button

Batterysaver tab

Gap no morethan 8mm

Magnet

Sensor

Learn/Testbutton

LED

Batterysaver tab

aleY R

1 2 3

6547 8 9

0

AB

Disarm

HomeArm

Arm

LED

Page 6: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

6

First Time Easy Set-up

•Anyomissionsormistakescanberectified later. Once the first time install has been successfully completed it will not be shown again.

•Moreadvancedprogrammingcanbedone at a later stage including adding and naming sensors and changing various settings.

Connect the mains power adaptor to the control panel (in the intended location). After the welcome screen, the display will show:

3 Steps easy setup (ok?)

Press OK (3) to continue. You are 3 steps awayfrom completing the initial set-up.

3 The installation guide will provide you with prompts to easily set-up the system.

i

1. Set Time/Date

Set date/time (ok?)

Press OK (3) to continue.

Set date,pressok when done(ok)

Press OK (3) to continue.

date setting 01 jan (pqOK)

Set the current month using the p/q key. Press OK (3) to confirm setting. Set the day using the p/q key. Press OK (3) to confirm setting. After setting the day, it will now prompt you to set the time.

Set the current time using the p/q key. Press OK (3) to confirm the hour, follow by setting the minutes.

2. Set the phone number to alert

Set 1 phone num for alert (ok?)

Enter a phone number to be alerted in the event of an alarm.

Press “Up arrow” key for + key or enter numbers.

Press OK (3) to continue.

Press Return button to clear the entered number or skip if you do not want any alert through the phone.

3. Set the Pincode

Set pin code ....

Enter the four digit pincode you would like to use (e.g. 1234). Press OK (3) to continue.

Page 7: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

7

Next, the screen will display:

.Exit setup Repeat Setup

Upon selecting “Exit Setup”, you will now be prompted with:

mount devices, see Manual

Please leave it on this screen and proceed to

mount all your devices (see Chapter 4).

Note: If a different prompt is shown, please see section on the right.

Error Condition (Upon selecting Exit setup)

If there are no device/accessory (accidentally deleted) in the system and you selected “Exit Setup”, you will be prompt with “Please add at least one device”.

Please add at

least one device

If you see this message, please press the test/learn button on all your accessories (please add Siren later) one at a time.

Every time a button is pressed, the screen will prompt the device and you will need to press OK on the panel to acknowledge/add. It would then be reverted to the “Exit Setup, Repeat setup” screen. Please press the learn button on the next device and repeat the above steps. Please ensure all the devices are added one by one.

Choose “Exit setup” once everything is added.

i

Alternatively, should you wish to finish initial setup

with no device learnt-in, you can force exit by pressing disarm and then followed by the pincode.

You will now be prompted with:

mount devices, see Manual

Please leave it on this screen and proceed to mount all your devices (see Chapter 4).

Page 8: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

8

Post Installation/Mounting Devices4 Note: Tamper is disabled during initial set-up. For details on disabling tamper see Section 6

Control Unit Mounting

Wall Mounting

Using the two holes on the mounting back plate, mark the position of the holes. Drill two holes and fix with the screws and plugs provided. Hook the control panel onto the plate. Ensure that the control unit is fitted at approximately chest height where the display can be easily seen and the keypad convenient to operate. • The control unit tamper protection will

automatically arm when mounted on the back plate.

NOTE: At this point, the control panel screen should be showing:

mount devices, see manual

Mounting other devices

Find a location where the device is to be mounted, see section “Location Planning” for suggestions.

Before proceeding to mount the devices physically, check that the control unit will receive the system radio transmissions by doing a simple radio range test.

Please make sure the control unit screen is displaying:

mount devices, see manual

Hold the devices in the desired location and press the Test/Learn button (see below) on the accessories.

• KEYPAD: press arm button.

• ALL OTHER DEVICES: Hold the device in the desired location and press the learn/test button, the control unit should respond with a chime.

If the sensor signal reached the control unit, the screen will briefly display:

dc zone01 b 6........

*Note: this screen shot is use as example only.

The radio signal strength is shown by a number on the upper right (6 in this case). this number ranges from 1 to 9 (strongest). Where possible please ensure sensor shows 3 or above for optimal performance.

When you are happy that all your devices can communicatewiththepanel,presstheGreen“Disarm” button and enter your pincode that you previously defined. The screen will now show:

Alarm Off 00:00 01 jan

Leave it at this screen and proceed to mounting the accessories as detailed below. The fault light/beep maybe activating periodically and you can ignore that until you finish mounting.

Mounting the siren

Ensure the tamper switch is fully depressed whenthe siren is mounted. If there is a gap, pack with asuitable spacing material.

RoundSirenBase

Wall

Spring Guide

Spring compressedfirmly against wall

1 Using the large screws and wall plugs provided, screw the siren onto the wall through the 4 mounting holes on the siren base.

2 Fix the siren cover with the securing screw.

Mounting the PIR

1 Open the PIR by loosening the bottom screw.Knock out the relevant holes on the base where the plastic is thinner. The center two knockout holes are for flat wall mounting while the 4 side holes are for corner mounting.

Page 9: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

9

2 Drill holes into the wall using the knockout holes on

the base as a template.

3 Fit wall plugs and secure the PIR base with the screws provided.

4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete.

Mounting the Keypad:

1 Drill holes into the wall using the fixing holes as a template.

2 Fit wall plugs into the wall and fix back cover with the screws provided. Put the keypad into the bracket.

Mounting the Door Contact

Frame

Door/Window

Gap no morethan 10mm

MagnetSensor

Sensor

ale Y

1 Find a location on the door/window where you would like the device to be mounted. The sensor should be on the frame while the magnet should be on the door/window. Once mounted make sure the tamper switch spring is fully depressed.

The gap between the magnet and sensor should be no more than 10mm when closed (maybe shorter depending upon the actual environment).

Simple test to see whether the magnet is in range of the sensor: hold the magnet and sensor in place and then pull them apart. If the sensor LED lights up it implies the two items are within range.

i

-Mounting using adhesive pads Clean the mounting surface with a suitable

degreaser agent. Please note that some surface or environment (i.e. exposure to Sunlight) maybe unsuitable for this mounting method. Please use screw mounting in these cases.

-Mounting using screws and wall plugs Loosen the bottom screw

and open the door/window contact. Knock out the holes on the base as shown. Drill holes into the mounting surface using the holes in the knockouts on the base as template. Fit wall plugs (if required) and secure with the screws provided.

Mounting the Help button

1 Break through the knockouts (where the plastic is thinner).

2 Using the holes as a template, drill holes in the surface and insert wall plugs if fixing into plaster or brick. Screw the rear case to the wall.

3 Replace the cover and tighten the screw.

Mounting the Smoke Detector

1 The base has two mounting slots. Using the slots as a template, drill holes and insert the wall plugs if fixing to plaster. Screw the rear case to the ceiling using the screws provided.

2 Replace the main unit onto the bracket.

Knockouts

Corner fixingknockouts X 4

Wall fixingknockouts X 2

Fixing Slots X 2

KeypadCradle Open

Page 10: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

10

About your alarm system (default settings)

To set up more telephone numbers (maximum 6 in total), please see Chapter 5, Tel. Settings.i

To change, please see Chapter 5, Adv. Settings, Alarm Length.i

To change the exit and entry timer, see Chapter 5, Adv. Settings.

To change the property of individual sensor (i.e. Burglar attribute where the individual sensor will instantly alarm when triggered), see Chapter 5, Devices, Edit Devices.

Home arming is disabled by default. If you need Home arming function, see Chapter 5, Home-arm set.

iAll accessories were pre-set to “entry” attributes.

When the system is first armed, user will have 30 seconds to exit the building. System will ignore any sensors triggering in this duration.

If the system is already armed, triggering any sensors will cause an entry countdown to begin.

When the alarm is triggered, the system will dial out to alert the owner.

Siren length is set to 3 minutes.

Jamming and interference detection disabled as default.

If Jamming and interference is of concern, please see Chapter 5, Adv. Settings, Jamming Det for option.

i

Page 11: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

11

Control Panel Menu System in Detail

Entering Programming Mode

The programming mode is for you to configure the system, and make any changes to the pre-set functions.If the system is in Disarmed (Alarm off) mode, follow the steps below to enter the programming mode.

1 Press Disarm key on the control panel. The screen will prompt you to enter the PIN code.

E n t e r C o d e. . . .

2 Key in your PIN code within 30 seconds.

Note•PressP to clear the entered PIN. If the code field

is empty, it will return to the Alarm Off screen.

3 Then the Programming Main Menu will typically be displayed.

* S y s t e m t e s tH o m e - a r m s e t

Note•Thecursorisindicatedbyaflashingdotontheleft

upper corner. It can be moved up and down by pressing pq respectively.

4 The following items can be selected:· Fault log (only if there is a fault condition)· System Test· Home-arm set.· Devices· Log· Adv. Settings· Tel. Setting· GSMSettings

5 After making a selection by moving the cursor to the desired item, press 3 to confirm the selection. Selecting P will return to the Alarm Off screen.

Important Note•Inprogrammingmode,ifnokeyispressedwithin

5 minutes, the panel will exit the programming mode and return to the Alarm Off screen.

System TestWhen System Test is selected, you will be given 4 different options: Sensor Test, External Siren (test), Panel Siren (test) and Phone alert.

Sensor Test:

three beeps will sound during a screen self test. This allows you to test the system without causing an alarm. To test if the control panel is receiving a signal, do one of the following depending on the device:

1 Press Arm on the keypad2 Press the test/learn button on the sensor3 Press the help button

A chime will sound and the display will show you which device is transmitting.The upper right corner will show the radio signal strength ranging from 1 to 9 (strongest). Relocate the sensor if this is below 2 (unstable).

Ext. Siren and Panel Siren (test):

•Theexternalsirenandcontrolunit(panel)sirencanbe tested by pressing 3 when prompted. Press 3

once more to stop the siren.

Phone alert:

•Selectthisoptionforatestcallviaphonedialler.

Home-arm set.

The home mode allows the home to be partially armed so that no one can get inside without first disarming the system. However, the person inside the house can move freely around without triggering the alarm. Home mode is usually used to protect the ground floor when you are upstairs in bed.

To enable home arm, you will first need to choose the sensors to be ignored during this mode. It would typically be the bedroom PIR etc if you want to arm your system during the night.

Selecting this option, the screen will display:

Press test on sensor to ignore

5

Page 12: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

12

If you press any test/learn button on any learnt-in sensor (confirm by pressing 3), these sensors will be ignored during the Home Arm mode.

Repeat this step to ignore additional sensors.

DevicesSelect ‘Devices’ in the main programming menu to add or remove a device. From here you will be able to view a list of all the devices being installed and you can add or delete devices. The following items can be selected.· Add Device· Edit Devices· Remove Device· Program Siren

Add Devices

1 To learn-in a new device select ‘Add Device’ then press 3, a “Push Button on Device to Add” message will be shown.

2 Press the learn button on the device within 30 seconds (see Chapter 2 for location).

3 If a signal is detected, the screen will show the type of device found. Press 3 to confirm

•Devicesarelabelledbythefollowingcodeswithin the control unit:

· Door Contact DC · PIR Sensor IR · Smoke Sensor SD · Remote Keyfob RC · External Siren BX · Remote Keypad KP · Help Button FP (Fix-Panic)•Whenasensorisaddedtothesystemfora

second time, an error “Already exists in System” message will be briefly displayed and the control unit will wait for another learn-in signal.

4 Press 3 to confirm the device type.

5 Thefollowingzonetypeswillneedsettingfordoorcontacts and PIRs:

· Burglar · Home Omit · Entry

The following devices have a fixed emergency zone type: · Smoke Detector · Remote Controller emergency Button · Help Button · Remote Keypad dual emergency buttons · Control Unit dual key emergency (1 and 3) keys

Zone Type ListBurglar•Whenthesystemisinhomeorawayarmedmode

and a burglar device is triggered, a burglar alarm will be activated immediately.

•Adevicesettoburglarwillnottriggeranalarmduring entry or exit delay periods.

Home Omit•Ahomeomitdevicewillbeignoredwhenthe

system is home armed.•Ahomeomitdevicewillgiveaburglaralarmwhen

the system is away armed.

Entry•Ifanentrydeviceistriggeredwhenthesystemis

either away or home armed, it will start an entry delay period to give enough time to disarm the system.

•Ifthedelayperiodexpireswithoutbeingdisarmed,the control panel will respond with a burglar alarm.

•Ifthedevicehasbeensettoentryandtriggeredwhen the system is in disarmed mode, the control unit will make a ‘ding-dong’ door chime sound if the door chime feature is enabled.

Emergency (Auto assign)•Anemergencydevicethatisactiveallofthe

time does not have to be armed or disarmed, if triggered an emergency alarm will be activated immediately.

Edit DevicesTo edit all of the devices that has already been installed, choose ‘edit devices’ in the device +/- menu. All of the devices included in the system will be displayed.

1 Use st keys to scroll the display and choose the device for editing. Press 3 to select. Depending onthedevicealistofzonetypeswillbegiven,otherwise you will be asked to enter a name.

2 Ifavailableselectazonetypeandpress3 to confirm.

Page 13: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

13

3 You are now asked to enter a name. Press 3 to confirm or P to cancel without naming.

Device Naming

•Eachdevicecanbegivena12charactername.Names can be given either when first adding a device or by editing them later.

•Whenthe“Enter New Name” screen is displayed the numeric keyboard can be used to enter text. Simply find the corresponding numeric key with the required character and press repeatedly until the wanted character appears. Release the key and the flashing cursor automatically jumps to the next position for you to continue with the next character by the same method.

•Thekeyshavethefollowingfunctions:1 12 2ABCabc3 3DEFdef44GHIghi5 5JKLjkl6 6MNOmno7 7PQRSpqrs8 8TUVtuv99WXYZwxyz00<space>/&’.”+P Backspace and delete

•Thenamecanbeerasedbyclearingthedisplaybypressing P repeatedly, followed by 3.

4 Press 3 when completed to confirm the name and return to the device list.

Remove DeviceTo delete a device choose ‘remove device’ in the “Edit device” menu. A list of all programmed devices will be shown.

1 Use st keys to select the device you wish to delete and press 3.

2 The selected device will be displayed again, press 3 to confirm deletion or P to return to the device list without deleting.

•Ifadevicenamehasnotbeenprogrammedthescreenwillshowthepresetzonenumberinstead.

Program SirenTo program the siren, select ‘Program siren’ under the “Devices” menu. The following items are available in this menu:• Learn Siren

• Siren Tamp. On• Siren Tamp. Off• Confirm On• Confirm Off• Entry Snd On• Entry Snd Off

Learn Siren•Thecontrolunitrequiresthatatleastonedevice

is programmed into the system before the siren is added.

•Putthesirenintolearnmodebypressingthelearnbutton on the siren. The siren LED will flash.

•Onthecontrolunit,usest keys to select the “Learn Siren” menu.

•Press3 on the control unit.•Thecontrolpanelwillgivealongbeepand

transmit a signal to the bell box. The bell box should respond by activating its siren and strobe lights momentarily when any command is sent to it. Press learn button on the siren to exit learn mode.

Siren Tamp. On, Siren Tamp. OffThe siren tamper switch can be enabled and disabled remotely.

•Thesirentamperprotectionautomaticallyswitchesback on after one hour.

Confirm On, Confirm OffThe siren can be enabled for arming and disarming confirmation where one pip and flash is given for arming, with two pips and flashes from side to side for disarming.

Entry Snd On, Entry Snd OffThe entry and exit warning beeps can be echoed onthe siren.

LogThe alarm log memorises recent system events including:· All alarm events with device names and type· All fault warning events· All arming and disarming events•Theloggedeventsaredisplayedinreversed

chronological order (most recent event first).•Thelogismarkedwitha‘start’labelbeforethe

most recent entry and ‘end’ after the oldest entry.To view log:

Page 14: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

14

1 Select the Log menu and press 3.

2 The log can now be scrolled up and down and viewed with the st keys; the most recent event will be at the start.

3 The first line displays the time and date of the event, the second line displays the type of event and the third line either states the user or the device that caused the event. Abbreviations used are: · “LB”: low battery · “Tamp”: tamper · “R”: restore. · AC: mains power · Panic: emergency · Perimeter: entry or away entry device · Cancel: silencing an alarm with a help button

Adv. SettingsThe settings will initially have factory default values. If you do not want to change them then you can escape any menu by pressing P without making changes.

The following items are available in this menu:

· Pin Code· Entry Time· Exit Time· Entry Sound· Exit Sound· Door Chime· Alarm Length· C.U. Siren· Jamming Det · KF Entry· Time· Date· Final Door

Pin CodeThe PIN Code (password) is used to configure the control unit and to disarm the system.•Todisarm,pressthe‘disarm’keyfollowedbyyour

PIN code.•Toentertheprogrammenupressthe‘menu’key,

enter a PIN code followed by 3.•Upto4Pincodescanbestored.

1 Select ‘Pin Code’ then press 3, a list of 4 PIN codes will be shown, occupied codes are shown with ****. The list can be scrolled up and down using thest keys.

2 Select the code you want to change and press 3, enter your new PIN code and press 3. You will be asked to repeat the PIN code, enter it again and confirm by pressing 3, You will now be asked to name the PIN code. The new code is now programmed.

•P can be used to correct entry errors, pressing P repeatedly will return you to the PIN code list.

•User1codecanonlybechangedandcannotbeerased. All other codes can be erased by selecting them and pressing 3.

•Anerrormessagewillbeshownifeitheranincorrect repeat code is used or a duplicate code is entered for another user. All codes have to be different.

Entry TimeNote: Ensure device is set to entry on control unit for the entry time to work (see section 5, Add Devices)

Entry time gives you a delay to allow you time to enter your premises and disarm the system. Times can be set from 00 seconds (no delay) up to 70 seconds in 10 second increments.•20secondsisthefactorydefault.

Exit TimeExit time gives you a delay to allow you to leave your premises before the system arms. Times can be set from 00 seconds (no delay) up to 70 seconds in 10 second increments.•30secondsisthefactorydefault.

Entry SoundThe control unit will beep during the entry delay period as an entry warning, you can switch the sound on and off with this setting.•Entrysoundonisthefactorydefault.

Exit SoundThe control unit will beep during the exit delay period as an exit warning, you can switch the sound on and off with this setting.•Exitsoundonisthefactorydefault.

Door ChimeAny door contact or PIR set to entry will cause the control unit to chime when activated when the system is disarmed. This is used to signal when anyone has entered your premises. You can switch the sound on and off with this setting.•Chimeoffisthefactorydefault.

Page 15: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

15

Alarm LengthThe siren (both external and built-in) will sound when an alarm is activated. The length of the alarm can be set from 1 to 15 minutes in 1 minute increments with this setting.•3minutesisthefactorydefault.

C.U. SirenYou can disable the control unit’s built-in siren with this setting.•Sirenonisthefactorydefault.

Jamming DetEnable or disable Jamming/Interference detection on the control panel. Confirmed by pressing the 3 key. Default setting is Disable (recommended).

KF EntryWhen selected as Off, user must first trigger an entry sensor before the keyfob can disable the system. Please select On if you wish to disarm the system without first triggering an entry sensor. •KFEntryOnisthefactorydefault.•IftheKeyfob’sPanicbuttonistriggered,thesame keyfob cannot be use for disarming the siren.

TimeThe control unit uses a 24 hour clock. The time is set by using the pq keys and confirmed by pressing the 3 key.

DateThe day and month are set by using the pq keys and confirmed by pressing the 3 key.

Final DoorIf this is turned On, a system counting down under the full arm mode will immediately arm when user exit and triggers the Door contact’s close position (Applies to door contact with “entry” attribute only). •FinalDoorOffisthefactorydefault.

Tel. Settings

This menu allows you to program up to 3 telephone numbers, record an address message and place test calls, The following items can be selected.•Tel.Numbers•Rec.Msg•TestReport

Tel. NumbersThis menu has a list of 6 telephone numbers (notify via voice dial or SMS). These numbers are dialled/SMS in order, a maximum of 20 digits per number can be stored. Only one number is required to enable the control unit to report over the telephone line.

1 Use the pq keys to select a number from the list.

2 Press 3 to confirm. If there was a number already stored then you will be asked to change the number, if the slot was empty you will be asked to enter a new number, confirm by pressing 3.

3 Enter your phone number and confirm by pressing 3. Errors can be corrected by pressing P to backspace, pressing P repeatedly will take you back the telephone number list. Telephone numbers can be deleted in the same manner.

4 Once a number is entered, you will be ask whether to use voice or SMS reporting. Please note that SMS reporting can only work with mobile numbers. If you select SMS reporting, it will further

ask you what type of event should trigger a report.

Rec. MsgThis menu allows the recording of your message. The maximum length of message is 10 seconds which is ample for most messages, when recording remember to speak clearly and slowly into the microphone.

1 Press 3 and you will be either asked to record a new message or change an old one.

2 Press 3 again and follow the on screen instructions. When you finish recording remember to press 3 to stop recording. If you go over the 10 second recording time (indicated by a beep) just repeat the recording procedure again taking care not to go over the 10 second time limit. The recording is complete.

Test reportThis menu allows you to test the telephone reporting feature. •Pleasecheckwiththecallrecipientsbeforemaking

a test call.•Ensurethatthesimcardisinsertedandworking.

The sim card should not have pin code protection.

Page 16: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

16

1 Select Test report and press 3.

2 A list of numbers will be displayed, select the number you want to test and press 3.

3 The control unit will now display test progress.•Thetestcanbecancelledatanytimebyeither

pressing the P button or the call recipient pressing “9” on their phone to acknowledge the call. If a radio DECT or mobile phone is used, remember to press 9 repeatedly until the call closes.

•Checkthatthecall/SMShasbeensuccessfullyreceived.

GSM SettingsThismenuallowsyoutoconfigureGSMspecificsettings, The following items can be selected.

•PeriodicSMS•GSMsignal•SMSKeyword•ResetGSM

Periodic SMSUse this feature to avoid pre-paid sim card credit expiring. •Thecreditinapre-paidGSMsimcard(PAYG)often expires after 90 days of inactivity (please check with your provider). This option allows you to set an automatic SMS period (between 10 days to 180 days). By sending out SMS periodically it will keep the sim card live and avoid credit expiring.

GSM signal strengthYoucancheckyourGSMsignalstrength(strongest= 9), Please relocate your panel should the value fall below 4.

SMS KeywordIf you want to control your system remotely using SMS, you need to set a keyword for security reasons.•PROGisthefactorydefault.

Reset GSMShouldyourGSMdevelopfaults,youcanresettheGSMsimcardusingthisoption.

Page 17: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

17

Using the System

The PIRs have a built-in sleep timer to savebattery power. If there is no movement in frontof the PIRs for 1 minute, the PIRs will become‘ready to signal’ and movement will now bereported. The PIRs will sleep for 1 minute after reporting.

Any movement detected in sleep time will not bereported and will extend the sleep period by afurther 1 minute.

i

Away Arm

Arming the System1 When the system is disarmed (alarm off), press the

arm key on the control unit, keypad or keyfob.2 The control unit will start its countdown.3 When the exit delay time is up, the control unit will

sound a long beep. The siren will beep once and the strobe will flash once after the exit delay has expired. ‘Alarm on’ will be displayed on the screen and the system is now in away armed.

4 If there are faults within the system, i.e. the tamper switch of a sensor left opened, the user will not be able to arm the system with a single press. The user can use the control panel, keypad and keyfob to force arm the system by pressing arm twice.

Stopping the Exit Delay by Disarming1 Press the disarm key on the keyfob or press the

disarm key followed by a PIN code on the control unit and keypad.

2 ‘Alarm off’ will be displayed on the screen and the system will return to disarmed mode.

Extending the Exit Delay•Theexitdelaytimecanbeextendedduringthe

exit delay period by pressing the arm button on the keypad or keyfob. Each time the arm button is pressed, the delay time starts counting from the beginning.

Alarm Activation•IfanyDoor/WindowcontactorPIRsensorsetto

entry or away entry is triggered, the entry timer will be started. If the entry timer is allowed to expire the alarm will be activated.

•Ifothersensorsnotsettoentryorawayentryistriggered, the alarm will be activated immediately.

Disarm

Disarming the System

1 Press the disarm key on the keyfob or press the disarm key followed by a PIN code on the control unit and keypad.

•Thekeyfobwillonlydisarmthesystemduringentry time after an entry or away entry door/window contact or PIR has been triggered.

2 The control unit will sound two beeps. The siren will beep twice and the strobe will flash side to side. ‘Alarm off’ will be displayed on the screen and the system is now disarmed.

3 The control panel will lock out for 5 minutes with 5 beeps if the PIN code had been entered incorrectly for five times.

Home ArmThe home mode allows the home to be partially armed so that no one can get inside without first disarming the system. However, the person inside the house can move freely around without triggering the alarm. Home mode is usually used to protect the ground floor when you are upstairs in bed.

Arming in Home Mode1 When the system is disarmed (Alarm off), press

the home arm key on the control unit, keypad or keyfob.

2 The control unit will start its countdown.3 When the exit delay time is up, the control unit

will sound three short beeps. The siren will beep once and the strobe will flash once after the exit delay has expired. ‘Home’ will be displayed on the screen and the system is now home armed.

4 If there are faults within the system, i.e. the tamper switch of a sensor left opened, the user will not be able to arm the system with a single press. The user can use the control panel, keypad and keyfob to force arm the system by pressing arm twice.

Extending the Exit Delay•Theexitdelayperiodcanbeextendedinasimilar

manner as described in Away Arm.

Alarm Activation•Ifanydoor/windowcontactorPIRsensorsetto

entry is triggered, the entry timer will be started. If the entry timer is allowed to expire the alarm will be activated.

•Homeomitandawayentrysensorswillbeignored.

•Ifothersensorsnotsettohomeomit,entry

6 Arm and disarm the system and practice using it. Trigger the alarm by arming the system andopening protected door/windows and walking past PIRs. Now is the time to show the rest ofthe family how simple it is to use.

Page 18: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

18

or away entry are triggered, the alarm will be activated immediately.

Stop the Alarm and Alarm DisplayDuring an alarm, the control panel and outside siren will sound and dial the emergency phone number. The control unit will display “ALARM! ALARM!” to notify the user. Stopping the Alarm1 Press the disarm key and enter a user code on the

control unit or keypad. The control unit will sound a long beep and display the device that caused the alarm. The siren will beep twice and the strobe will flash side to side.

•Thekeyfobcannotstopanalarmcausedbyburglar or emergency device.

2 When the control unit is displaying the source of the alarm, pressing any key will display the telephone number that it dialled out and acknowledged (if any). If there were more than 2 numbers that were acknowledged the numbers will be shown by pressing further keys.

3 When “Alarm off” is displayed the system is disarmed.

Alarm Memory•Ifanalarmwasraisedduringyourabsence,and

the alarm sequence has been carried out, the screen will continuously show “ALARM! ALARM!”.

•Thisindicatesthattheremightstillbeanintruderstill in the house. Disarm the system as normal.

•Toclearthe“ALARM!ALARM!”display,followthesame steps as ‘Stopping the Alarm’ described above.

Dialling & Call Acknowledgement

Auto Dialling•Ifthesystemisinawayarmmode,whenanalarm

occurs the control unit will immediately dial the preset phone numbers (Voice call or SMS)

•Ifthesystemisinhomemodeordisarmedmodewhen an audible alarm is initiated, the control unit will wait for 15 seconds before dialling the preset phone numbers.

•Forvoicecall,thecontrolpanelwillwait5secondsthen playback the messages in a loop. It will first play the recorded address message then the

pre-recorded messages (Burglar, Emergency) depending on the nature of the alarm and finally an acknowledgement request message.

•Therecipientshouldacknowledgethemessagebypressing ‘9’ on their telephone when prompted.

•RecipientsusingradioDECTphonesormobilesshould press the numbers repeatedly until the call is closed.

•Ifthecontrolunitdoesnotreceiveanacknowledgement, the messages will be repeated for a period of 80 seconds before attempting to dial again. Each number will have 5 call attempts.

•Thecontrolpanelwillcontinuetodialthenumber(s) until a call is successfully answered with a ‘9’ acknowledgement.

•Systemauto-diallingfeaturesonlyoperateundertone-dialling method.

•Whennotelephonenumberisstored,thecontrolpanel will not dial out.

Remote Dial-in Access

The control unit allows you to control your system remotely through the telephone line.

1 Dial the phone number associated with the Control panel.

2 Hang up on the first ring.3 Wait 5-10 seconds.4 Dial the number again.5 The control unit will answer the phone on the first

ring of that second call. You will hear two beeps.6 Enter your PIN Code within 3 seconds.7 If the PIN code is correct, you will hear another

two beeps. A list of different functions is detailed below:

Press 01 Listen-in through the panel microphone

Press 10 Disarm the system.

Press 11 Full/Away arm

Press 12 Part/Home arm

Press 00 Disconnect, or the control unit will hang up automatically after 30 seconds.

Page 19: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

19

Disabling the system tamper

Before mounting it is important to disable the siren and system tamper to avoid the siren sounding an alarm.

1 Press the Menu key and enter a user PIN code followed by 3.

2 The control unit is now in programming mode, Select Devices, then Program Siren and Siren Tamp. Off using the pq3 keys.

3 Press 3 when in the Siren Tamp. Off menu and the control unit will beep followed by an acknowledgement pip from the siren.

• Siren programming is described fully in “Control Panel Menu System in Detail” in section 5.

• The siren tamper will now be disabled for 1 hour after which it will automatically arm again. If longer is needed to fit the siren then simply repeat the steps above.

• Leave the control unit in programming mode to stop the system responding to tampers. If the control unit automatically times out, re-enter programming mode again.

i

Enabling the system tamper

After mounting the siren and detectors, please enable the system tamper by:

1 Press the menu key and enter a user PIN code followed by 3.

2 The control unit is now in programming mode, Select Devices, then Program Siren and Siren Tamp. On using the pq3 keys.

3 Press 3 when in the Siren Tamp. On menu and the control unit will beep followed by an acknowledgement pip from the siren.

4 Quit programming mode and system tamper protection will be automatically restored.

i

Page 20: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

20

Adding and using Accessories

PreparationSee section 2, for battery insertion or activation and part identification. See also section 1 and section 4 for installation details and suggestions.

Adding siren to your system

• See Section 5, Devices ->Program Siren ->Learn Siren

Adding accessories to your system

1 From the programming menu of the control unit, select the ‘Devices’ and press 3, select ‘Add Device’ and press 3 again.

2 Press the Learn button on the device when prompted and confirm it is the correct detector by pressing 3.

Learn buttons (see Chapter 2 for location):• Keyfob: Press arm• PIR: Press the test button• Door/Window contact: Press the test button• Help button: Press the emergency button• Smoke detector: Press the test button• Keypad: Press arm. The keypad will need

initialising first, see “Keypad code changing andsetting” on the right.

3 Depending on the device learnt in, finish the programming as prompted.

Using your keyfob

• ThekeyfobcanbeusedtoAwayArm,HomeArm, and Disarm the system using the buttons asshown.

• Anemergencyalarmcanbeactivatedbypressingthe emergency button for 3 seconds until LEDstops flashing.

• Anemergencyalarmcanonlybestoppedbyusingthe control unit keypad or a remote keypad.

• Thesystemcanonlybedisarmedafteranentryoraway entry sensor is activated (in the entry period).

/

KeypadKeypad code changing and settingThe keypad comes with a factory default code of ‘0000’. This code will need to be changed to the same code used in the control panel for the keypad to disarm the system. To do this, you will need to:

1 Press the ‘Panic button A’ key followed by factory default keypad code ‘0000’.2 The LED will now flash slowly indicating it is in test

(programming) mode.3 Press the ‘Panic button A’ key followed by the ‘8’

key to set the keypad into secondary mode.4 Quit test mode by pressing the disarm key twice.

The keypad code and mode setting has been completed. The Keypad will now use the same pincode that is set for the control panel unit.

aleY R

1 2 3

6547 8 9

0

AB

Disarm

HomeArm

Arm

LED

Forgotten keypad code (different to control panel code)

If the keypad code is accidentally forgotten, the keypad can be reset to factory default using the following steps:1 Unscrew the two keypad case screws and remove

keypad back cover. Locate and remove the battery.

2 Press the number ‘3’ key at the same time as reinserting the battery.

3 Screw the keypad case together and re-learn the keypad into the system using the steps described above in this section.

To provide additional protection you can add extra door/window contacts, PIRs, keyfob remote controls, keypad remote controls, help buttons and smoke detectors. These are available separately from your local stockist.

Page 21: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

21

Using your keypad• ThekeypadcanbeusedtoAwayArmandHome

Arm the system using the buttons as shown.• Thesystemisdisarmedbypressingthedisarm

button followed by any user code, similar to usingthe control unit keypad. Deactivate your panicevent by pressing disarm button followed by anyuser code.

• Anemergencyalarmcanbeactivatedbypressingthe panic A and B buttons simultaneously.Deactivate your panic event by pressing disarmbutton followed by any user code.

• Thekeypadusesthesameuserpincodesprogrammed into the control unit for disarming.

• Toextendtheexittime,pressthearmorhomearm button once more on the keypad.

• Ifthereisasystemfault,youwillneedtopressthearm/home arm button for a second time to “forcearm” the system.

Using your smoke detector

Smoke DetectionWhen smoke is detected the device will activate for a minimum of 10 seconds with a two tone alarm and flashing LED for a local fire alarm. The detector will send a radio signal to the control unit for activating a system fire alarm.

• Pressingthetestbuttonwheninanalarmcondition will silence the alarm for 10 minutes. Itwill automatically resume smoke detection againafter this period.

• Ifthesmokedensityisstilloverthealarmthreshold, then the smoke detector will remain inan alarm condition and it will repeat the local firealarm with a radio fire alarm signal to the controlunit.

Testing• Smokedetectortestingshouldbedoneona

regular monthly basis. Pressing the test button willmake the LED flash, the audible sounder chime willsend a radio test signal to the control unit whenthe button is released. If nothing happens afterpressing the test button, it indicates the batterieswill need changing.

Recalibration• Thesmokedetectormightneedrecalibratingafter

time to ensure it is working at its optimum. This isdone by pressing and holding the test button untilthe LED flashes and beeps after 10 seconds. Thedetector will then start its self calibration routine.

Using your Help Button

Activate an Alarm• Pressandholdtheredbuttonforatleast3

seconds. The LED will light momentarily and thealarm will be activated.

Silence an Alarm• Pressandholddowntheredbuttonfor10

seconds. The LED will light momentarily for asecond time and the alarm will be silenced.

• Pleasenotethatsilencingthealarmwiththehelpbutton does not reset the system. If the alarm isarmed prior to activation, the system will re-armafter being silenced with the help button.

• Thesystemwillrequirearesetatthecontrolunitafter being silenced with the help button.

Page 22: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

22

Changing the Batteries

Control unit low battery IndicationThe control unit will display all device low battery conditions with the exception of the siren. This is shown by a fault display with the fault LED lit on the front panel. In addition the devices also can show low battery conditions as described below. When a device first shows low battery signal it has enough battery capacity to operate for a further month before complete exhaustion.

Siren battery changeWhen the batteries start getting low the siren will produce a series of pips and flashes during arming and disarming.

1 Switch off tamper protection at the control unit as described in section 4 ‘Mounting alarm devices’.

2 Remove the siren lid and switch the siren power switch to OFF.

3 Unscrew the four screws on the battery compartment lid and remove the cover.

4 Remove the four batteries and replace them with four fresh alkaline “D” cells.

5 Switch on siren power and check that the siren beeps and flashes.

Warning: After the batteries have been changed the tamper will become active again, either be very careful when fitting the siren cover or switch off the tamper protection again.

6 Replace battery compartment lid and screws and reattach siren lid. Switch tamper protection back on.

•Sirencasetamperconditionsarealsosignalledby a series of beeps when the system is armed but not when the system is disarmed (low battery warning produces a series of pips when armed and disarmed), take care not to confuse the two different conditions.

PIR battery changeWhen the battery is low the LED will flash when any movement is detected. The batteries are changed as follows:

1 Put control unit into programming mode to prevent a tampered alarm.

2 Loosen the case screw and remove PIR sensor from base to reveal three AAA batteries.

3 Insert new alkaline batteries observing correct polarity. The PIR LED will flash for 30 seconds while initialising.

4 Refit sensor on base and tighten bottom case screw. Switch tamper protection back on.

•PIRcasetamperconditionsarealsoindicatedbya flashing LED, check the tamper before changing the batteries.

Door/Window Sensor battery changeWhen the battery is low the LED will light up when the door/window is opened. The battery is changed as follows:

1 Put control unit into programming mode to prevent a tampered alarm.

2 Loosen the case screw and remove door/window sensor from base to reveal battery.

3 Using a screwdriver gently lever out the old battery.

4 Insert new CR2032 coin cell with the + side uppermost.

5 Press battery into holder firmly with finger and thumb until a click is heard.

6 Refit sensor on base and tighten bottom case screw. Switch tamper protection back on.

•Door/windowsensorcasetamperconditionsare also indicated by a lit LED, check the tamper before changing the battery.

Always use alkaline batteries or the correct type of coin cells as replacements because any other battery can cause problems with the operation of the system. Typical life of batteries is two years or more. Ensure the correct steps are taken when changing batteries in tamper protected devices.

Page 23: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

23

Keyfob battery changeWhen the battery is low the LED will glow dimly when any key is pressed. The battery is changed as follows:

1 Using a coin turn the battery cover anticlockwise to the unlocked position and remove cover and battery.

2 Insert new CR2032 coin cell with the + side uppermost.

3 Replace battery cover.

Press any key and check that the LED lights. If the LED lights, the new battery installation is successful.

Keypad battery changeWhen the battery is low the LED will flash when any key is pressed. The battery is changed as follows:

1 Put control unit into programming mode to prevent a tamper alarm.

2 Unscrew the two keypad case screws and remove keypad back to reveal battery.

3 Using a screwdriver gently lever out the old battery.

4 Insert new CR2032 coin cell with the + side uppermost.

5 Press battery into holder firmly with finger and thumb until a click is heard.

6 Press a number key and check that the LED lights. If the LED lights the new battery installation is successful, screw keypad back on and the battery change is complete.

Help button battery changeWhen the battery is low the LED will glow dimly when the button is pressed. The battery is changed as follows:

1 Loosen the bottom case screw and take button cover off base.

2 Insert new CR2032 coin cell, taking care to observe polarity (see Section 2).

3 Replace button cover.

Press the button and check that the LED lights. If the LED lights, the new battery installation is successful.

Smoke detector battery changeWhen the battery is low the LED will flash accompanied with a Low-volume beep once every 30 seconds.

1 Rotate smoke detector anti-clockwise to detach from base bayonet fixing.

2 Insert new AA alkaline batteries, taking care to observe polarity and wait 15-20 minutes for he smoke detector to recalibrate itself, indicted by a rapidly flashing LED..

3 Replace smoke detector on base and rotate clockwise to lock.

4 Press the test button and check that the LED lights and the sounder chimes.

Page 24: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

24

Troubleshooting

SirenSiren does not respond to arming or disarming

•Sirenbatteriesarecompletelyexhausted. Check siren batteries by removing siren cover, if

there is no tamper alarm when removed, replace batteries with new alkaline equivalents.

•Sirennotlearnt-in.Ifsirenproducesatamperalarm when the cover is removed and siren is OK, learn-in the siren.

•Sirenoutofrange.

Siren produces a 3 second alarm when disarmed •Therehasbeenapreviousalarmandtheremight

be an intruder still in the premises.

Siren produces a series of pips when armed or disarmed •Thesirenhaslowbatteries.Checkthatthe

siren produces a series of pips when arming and disarming, indicating low batteries. Change batteries with new alkaline replacements.

•Thesirentamperswitchhasbeendisturbed.Check that the siren produces a series of pips only when arming, indicating a tamper fault. Check that the siren cover is firmly secured and the tamper switch plunger is in contact with the wall. If not, use suitable packing material to fill gap.

Siren produces an interrupted tone when sounding an alarm •Thesirenhaslowbatteries.Changebatterieswith

new alkaline replacements. _____________________________________________

PIRPIR does not respond to movement •PreviousmovementhastriggeredthePIRsleep

timer and is preventing subsequent movement detection. Arm system and vacate protected room for at least 1.5 minutes before testing.

PIR is slow to respond •Thisisnormal,thePIRhassophisticatedfalse

alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view, it is less sensitive walking directly towards it.

PIR gives false alarms •Checkpetshavenoaccesstoprotectedarea.•CheckthatPIRisnotpointedatsourcesofheator

moving objects, e.g. fluttering curtains.

•CheckthatPIRisnotmountedaboveconvectorheaters or pointing directly at windows.

PIR LED flashes •Batteriesareloworthetamperswitchisdisturbed.

Check that the tamper switch spring is making contact with base. If the tamper switch is OK, change batteries with new alkaline replacements.

PIR does not respond to movement•Batteriesarecompletelyexhausted.Change

batteries with new alkaline replacements, LED will flash for 30 seconds while components initialise.

_____________________________________________

Door contactDoor contact LED lights up•Batteriesareloworthetamperswitchdisturbed.

Check that the tamper switch spring is making contact with the mounting surface. If the tamper switch is OK, change batteries with new CR2032 coin cell replacements.

Door contact does not respond to door opening when jumper is in test position •Batteriesarecompletelyexhausted.Change

batteries with new CR2032 coin cell replacements.

•Themagnetistoofarawayfromthedoorcontact.Check that the gap between door contact and magnet is not greater than 8mm.

_____________________________________________

Control unitUser PIN code is not accepted by the control unit.•Donotpauseformorethan5secondsinbetween

pressing the keys on the keypad.•Incorrectcodeentered.Re-enterthecorrectPIN

code.•Resetsettings-see‘ResetProcedure’and

reprogram the system._____________________________________________

Voice - Dialler not responding to alarm•Checkthetelephonelineisconnectedand

that the correct telephone numbers have been programmed.

For online assistance, please visit: www.Yale.co.uk

Page 25: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

25

_____________________________________________

Amber triangle LED illuminates and warning beeps (every 30 seconds if enabled)

•Thereisafaultconditioninyouralarmsystem.Note: this may be a simple fault that can easily be rectified, for example replacing low batteries in an internal PIR (movement) sensor.

•Pleaseviewthe‘faultlog’inthecontrolpaneltodetermine what the issue is. This is the first option in the programming menu. First press the ‘menu’ key and enter your user PIN code followed by pressing 3. Select ‘fault log’ followed by 3. You may need to scroll down using the q Key to check if there are multiple faults in the system. As an example, the display may read ‘DC Z01 tamper’, in which case you need to check the mounting of the tamper spring on door contact zone01torectifythisfault.Inthecaseoflowbatteries, you may see ‘IR Z02 LB’. Replacing the batteriesinPIRzone02willclearthisparticularfault. Other reported faults include: Interference, Tamper, Radio Device Low Battery and AC Power Fail etc.

•Iffaultshasnotbeenclearedfromthe‘faultlog’,afault display will be show when the Arm or Home Arm keys are pressed, with the device and fault that is causing the problem.

•Ifmorethanonefaultispresentthenindividualfault messages will be displayed sequentially at 2-second intervals.

IMPORTANT:

Please enter the programming menu first before swapping out batteries- otherwise you will trip the system tamper alarm.

Press the ‘menu’ key and enter your user Pincode followed by pressing 3 . Stay in the programming menu. Then, disconnect the relevant sensor and replace batteries. If the control panel times out and returns to ‘Alarm off’, please follow the above steps again and repeat the process.

_____________________________________________

Complete Reset Procedure

Reset to factory default settingThe control panel can clear all programmed parameters by the following sequence:

1 Power down control panel and remove the battery.

2 Apply power while holding down the p key.

3 Release the p key when a tone is heard, ‘Enter Code’ will be displayed.

4 Enter the following key sequence: pqpqpqpq 3

5 Press the P key.

6 All programmed parameters are reset to factory default setting.

7 If more than 17 incorrect keys are entered, then the unit will revert to normal Alarm On mode.

Note•Oncethe‘SystemReset’isexecuted,allthe

programmed data is return to its default value and all the programmed devices will be removed. User will be prompt with the initial setup screen. Press the learn button (see Chapter 2 for location) on all accessories one at a time. Every time a button is pressed, the screen will prompt the device and you will need to press OK on the panel to acknowledge/add. Please ensure you learnt in all devices before exiting the initial setup screen.

Partial Reset Procedure

Reset to factory default setting however keeping memory of all learnt sensors.The control panel can clear all programmed parameters by the following sequence:

1 Power down control panel and remove the battery.

2 Apply power while holding down the p key.

3 Release the p key when a tone is heard, ‘Enter Code’ will be displayed.

4 Enter the following key sequence: pqpq 3

Page 26: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

26

5 Press the P key.

6 All programmed parameters are reset to factory default setting. All learnt sensors will be kept.

7 If more than 17 incorrect keys are entered, then the unit will revert to normal Alarm On mode.

_____________________________________________

Jamming/Interference detection

User can enable Jamming/interference detection should they feel it is a risk.

Detection via control panelFrom the panel’s menu system, select: Adv. Setting -> Jamming Det, Enable.

Detection via External SirenOpen up the siren (Disable tamper first, see earlier section) and switch the Dip Switch 2 to On position.

* Enabling these features increases the likely hood of false alarm (false positive scenario).

Page 27: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

27

Alarm sensor response table

Disarm Away Arm Home Arm Exit Away Arm Entry

Home Arm Entry

Burglar No action Instant Burglar alarm

Instant Burglar alarm

No action No action No action

Home Omit No action Instant Burglar alarm

No action No action No action No action

Entry Door Chime Start Entry Timer

Start Entry Timer

No action No action No action

Page 28: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

28

Specifications

All devices

Environmental conditions -10°C to 40°C, relative humidity 70% non-condensing for all units except the external siren. Siren: -20°C to 50°C, relative humidity 95% non-condensing

Radio operational range 30m in a typical domestic installation, range can vary depending on building construction, device positions and RF environment

Housings ABS/polycarbonate

Control unit

Display Backlit 2 x16 character LCDKeypad 18 keySiren Output 100dBA soundpressure @ 1m minimumZones 20 radio devicesRadio system 433.92MHzAMIntegral transmitter and super heterodyne receiver with jamming detectionPower supply Plug top adaptortype,input230VAC50Hz,output9VDC, 500ma, tested to EN 60 950Rechargeable battery Ni-MH,4.8V 600mah, charge time 72hrs, standby time 10hrsTelephone interface Tested toTBR 21. REN rating 1

Siren Siren output 104dBA soundpressure @ 1m minimumRadio433.92MHzAMsuperheterodyne receiver with jammingdetectionPower supply 6V, 4 x D alkalinecells. 3 years typical service life

Passive infra red (PIR)Detector

Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discriminationRadio 433.92MHzAMtransmitterPower supply 4.5V, 3 x AAA alkaline cells. 2 years typical domestic service life, 1-minute sleep timerMovement detection range 15m,110°

Door/window contact

Radio Microprocessor controlled433.92MHzAMtransmitterPower supply 3V, CR2032 coin cell. 2 years typical domesticservice life

Smoke detector Radio Microprocessor controlled433.92MHzAMtransmitterPower supply 3 x AA alkalinecells. 3 years typical domesticservice lifeTested to EN54

Keyfob remote control

Radio Microprocessor controlled433.92MHzAMtransmitterPower supply 3V, CR2032 coin cell. 3 years typical domestic service life

Keypad remote control

Radio Microprocessor controlled433.92MHzAMtransmitterPower supply3V, CR2032 coin cell. 3 years typical domesticservice life

Help button

Radio Microprocessor controlled433.92MHzAMtransmitterPower supply CR2032 coin cell.3 years typical domestic service life

Page 29: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

2917

Model: HSA3400

HSA3020

HSA3060

HSA3010

HSA3050

HSA3045

HSA3080

HSA3030

HSA3070

ASSA ABLOY Ltd.School StreetWillenhallWest MidlandsEnglandWV13 3PW

HSA6010

HSA6020

HSA6021

HSA6050

HSA6060

HSA6080

HSA6090

HSA6091

HSA6500

HSA3045

HSA3070

Date: 07/10/14

On behalf of ASSA ABLOY Ltd.

ASSA ABLOY Ltd.School Street, Willenhall

West MidlandsEngland, WV13 3PW

John Ward Director

17

Model: HSA3400

HSA3020

HSA3060

HSA3010

HSA3050

HSA3045

HSA3080

HSA3030

HSA3070

EN 300 220-1 / V2.1.1 (2006-04) EN 301 489 -1, / V1.6.1 (2004-12) EN 301 489-3, / V 1.4.1 (2002-08) EN 60 950 / 2001 + A11 + corrigendum 2004

Page 30: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

30

Remote SMS controlInsteadofusingremotedial-intocontrolyourpanel,youcandownloadtheYaleGSMcontrolapp to SMS your panel with control commands.

Downloading the appGotoiOSappstoreorGooglePlaytosearchfor“YaleGSMcontrol”phoneapp.TheappwillsendanSMS controlled message from your phone to your alarm panel. Please check with your mobile provider for SMS cost.

Note: This app may not work correctly on certain GSMalarmmodels.PleaseuseremoteDial-inaccess instead (see Section 6).

Using the appUpon launching the app, you can add your new panel by pressing “+” on the upper right corner. You will see this screen below:

Panel Name: Please give your panel a name

Panel SIM: The mobile number of your alarm panel SIM card

PIN code: Your alarm panel PIN code

SMSKeyword:DefaultisPROG.YoucanchangethisKeywordfromthepaneloption:GSMsetting->SMS Keyword

Once you have confirmed this setting, select the panel and enter the main dashboard.

Please note that this app does not hold status information of your alarm panel. The settings shown on the app is the last command (or default), it is not synchronised with the alarm system.

Arming and Disarming

Press the Arm, Home or Disarm button to change your alarm mode. On an iOS phone it will brring up an SMS screen of which you will need to press “Send”. On an Android phone, the SMS is sent automatically.

Once the arming mode has changed, you will receive an SMS message from the panel as confirmation.

Page 31: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

31

PIN Settings

You can change your user PIN code or the SMS keyword. Pressing “Save” will trigger an SMS command to be sent to the panel. This is the same as “Adv. Settings” -> “PIN code”, page 14,

Note: Please change the panel setting by pressing “Edit” on the main dashboard- or else you will not be able to login.

To confirm this setting, press “Save” to send an SMS command to the panel.

Alarm Settings

You can change your user alarm panel setting here. This is the same as “Adv. setting”, page 14. Please note that the parameters shown does not reflect your actual alarm settings.

To confirm this setting, press “Save” to send an SMS command to the panel.

Report Settings

This menu has a list of 6 telephone numbers (notify via voice dial or SMS). These numbers are dialled/SMS in order, a maximum of 20 digits per number can be stored. Only one number is required to enable the control unit to report over the telephone line. This is the same as “Tel. Settings” -> “Tel. numbers”, page 15.

To confirm this setting, press “Save” to send an SMS command to the panel.

Device Settings

Reserved function, not supported.

Home Automation Settings

Reserved function, not supported.

Page 32: HSA6500 GSM alarm · 3 Fit wall plugs and secure the PIR base with the screws provided. 4 Fit the PIR back together and tighten bottom screw, the PIR installation is complete. Mounting

E2 05\15

THE YALE BRAND, with its unparalleled global reach and range of products, reassures more people in more countries than any other consumer locking solution.

THE ASSA ABLOY GROUP is the world’s leading manufacturer and supplier of locking solutions, dedicated to satisfying end-user needs for security, safety and convenience.

18

Specifications

All devices

EMCTested to ETS 300 683Radio Components tested to EN

300 220-1

Environmental conditions

-10°C to 40°C, relative humidity70% non-condensing for all unitsexcept the external siren. Siren: -20°Cto 50°C, relative humidity 95% non-condensing

Radio operational range

30m in a typical domesticinstallation, range can vary dependingon building construction, devicepositions and RF environment

Housings ABS/polycarbonate

Siren

Siren output 104dBA sound pressure @1m minimumRadio 433.92MHz AM super heterodynereceiver with jamming detection Power supply 6V, 4 x D alkaline cells. 3years typical service life

Passive infra red (PIR) detector

Alarm processing Microprocessorcontrolled dual edge sequential pulsecount with pulse length discriminationRadio 433.92MHz AM transmitter Power supply 4.5V, 3 x AA alkaline cells.3 years typical domestic service life, 1-minute sleep timer Movement detection range 15m, 110°

Door/window contact

Radio Microprocessor controlled433.92MHz AM transmitter Power supply 3V, 2 x AAA alkaline cells. 3years typical domestic service life

Smoke detector

Radio Microprocessor controlled433.92MHz AM transmitter Power supply 6V, 4 x AAA alkaline cells. 3years typical domestic service life

Keyfob remote control

Radio Microprocessor controlled433.92MHz AM transmitter Power supply 12V, 23A/MN21 alkalineminiature "lighter" battery. 3 yearstypical domestic service life Keypad remote control

Radio Microprocessor controlled433.92MHz AM transmitter

Power supply 3 x AAA alkaline cells. 3years typical domestic service life

Help button

EMC Tested to EN 300 220-1 and ETS300 683Environmental conditions -10°C to40°C, relative humidity 70% non-condensingRadio operational range 30m in atypical domestic installation. Can varydepending on building construction andRF environmentRadio Microprocessor controlled433.92MHz AM transmitterPower supply 12V 23A/MN21 alkalineminiature ‘lighter battery’. 3 yearstypical domestic service life

056018

Specifications

All devices

EMCTested to ETS 300 683Radio Components tested to EN

300 220-1

Environmental conditions

-10°C to 40°C, relative humidity70% non-condensing for all unitsexcept the external siren. Siren: -20°Cto 50°C, relative humidity 95% non-condensing

Radio operational range

30m in a typical domesticinstallation, range can vary dependingon building construction, devicepositions and RF environment

Housings ABS/polycarbonate

Siren

Siren output 104dBA sound pressure @1m minimumRadio 433.92MHz AM super heterodynereceiver with jamming detection Power supply 6V, 4 x D alkaline cells. 3years typical service life

Passive infra red (PIR) detector

Alarm processing Microprocessorcontrolled dual edge sequential pulsecount with pulse length discriminationRadio 433.92MHz AM transmitter Power supply 4.5V, 3 x AA alkaline cells.3 years typical domestic service life, 1-minute sleep timer Movement detection range 15m, 110°

Door/window contact

Radio Microprocessor controlled433.92MHz AM transmitter Power supply 3V, 2 x AAA alkaline cells. 3years typical domestic service life

Smoke detector

Radio Microprocessor controlled433.92MHz AM transmitter Power supply 6V, 4 x AAA alkaline cells. 3years typical domestic service life

Keyfob remote control

Radio Microprocessor controlled433.92MHz AM transmitter Power supply 12V, 23A/MN21 alkalineminiature "lighter" battery. 3 yearstypical domestic service life Keypad remote control

Radio Microprocessor controlled433.92MHz AM transmitter

Power supply 3 x AAA alkaline cells. 3years typical domestic service life

Help button

EMC Tested to EN 300 220-1 and ETS300 683Environmental conditions -10°C to40°C, relative humidity 70% non-condensingRadio operational range 30m in atypical domestic installation. Can varydepending on building construction andRF environmentRadio Microprocessor controlled433.92MHz AM transmitterPower supply 12V 23A/MN21 alkalineminiature ‘lighter battery’. 3 yearstypical domestic service life

0560NoPb

WEEENote: Waste electrical products and batteries should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

2 Year GuaranteeStatement

This product is guaranteed for consumers against faulty workmanship, materials and function for a period of 2 years from the date of purchase providing the full installation and maintenance instructions are followed. Please keep your proof of purchase safe, this must be submitted when making a claim under this guarantee.

Please note that it is a condition of this guarantee that your Yale product:

• Hasbeencorrectlyinstalledandmaintainedinaccordancewiththe Yale installation and maintenance instructions provided to you at the time of purchase.• Hasnotbeenmodifiedordamagedinanyway.• Hasnotbeensubjectedtounauthorizedrepairs.

Yale are responsible under this guarantee for repairing the product or replacing the product as we deem necessary. If there is fault with the product, please contact Customer Services on 01902 364647, who willgiveyouthenameofanexpertandconfirmwhatyouneedtodoto make a claim under this guarantee.

Please do not carry out any repairs without our authority or by using an unauthorised expert. Any repairs or other works carried out without our authorizationorbyusinganunauthorizedexpertwillnotbecoveredunder this guarantee.

This guarantee is non transferrable and applies to products purchased in the United Kingdom only. This guarantee does not apply to normal wear and tear. This does not affect your statutory rights. A full copy of this guarantee is available upon request by writing to Yale UK, School Street, Willenhall, West Midlands. WV13 3PW or by visiting our website www.yale.co.uk.