INDUSTRIAL ELECTRIC HEATING
CATALOGUE 2016
1
Engineering Company SSTenergomontazh
INDUSTRIAL ELECTRIC HEATING
CATALOGUE 2016
2
Table of contents
About the Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Complete engineering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Explosion hazard areas (overview) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Explosion safety and explosion proof electrical equipment (overview) . . . . . . . . . . . . . . . . . . . . . . 10
Heating cable selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Pipelines cooling time calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1. Industrial heating systems The TEPLOMAG system Self-regulating heating tapes НТМ (10, 15 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18НТА (10, 15, 20, 25 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20НТР (10, 15, 25, 33 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22ВТС (15, З0, 45, 60 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24ВТХ (15, 30, 45, 60, 80, 95 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26НТВ (12, 17 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CТE (80 W/m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Constant wattage cablesLLS LONGLINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32SNF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36SNF MF Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Flush-joint heating section based on TMF cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Mineral insulated cable MIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Induction-resistive heating system for pipelines of indefinite length (skin-system) . . . . . . . 44
Industrial Complete Device of Induction-Resistive Electric Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Thermal shielding membranes InWarm Reform Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Heat conducting paste SILARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
The TEPLOMAG system components Connection boxes РТВ 401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54РТВ 401-IS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56РТВ 402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58РТВ 402-IS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60РТВ 403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62РТВ 404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64РТВ 405 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66РТВ 406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68РТВ 601 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70РТВ 601-IS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72РТВ 602 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74РТВ 602-IS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76РТВ 605 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78РТВ 606 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80РТВ 1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82РТВ 1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Control cabinet heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Table of contents
3
Tabl
e of
con
tent
s
The TEPLOMAG system installation accessories Heating tape termination and splice kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Device for cable entry under thermal insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
2. Automated control systems Automatic control systems for electric heating (ACSEH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Electronic temperature controller РТ-400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100Electronic temperature controller РТ-410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Electronic temperature controller РТ-420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Electronic temperature controller РТМ-2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106Modular Measuring Transducer PTB/MMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Capillary thermostat exTHERM-AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
3. Switchgear equipment Main distribution boards (MDBs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Incoming supply distribution assembly (ISDA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115Automatic Transfer Switchboards ALT (ACP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Low voltage electrical cabinets (AEC, CC, PC, ALTC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Questionnaires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
4
Ab
out the comp
any
The SSTenergomontazh engineering company is the largest Russian developer and supplier of complex solu-tions on the electrical heating, thermal insulation and electrical engineering for various industry segments . As recognized experts in the field of design, installation, start-up and commissioning of cable heating systems (Turnkey Solution), we offer to our customers unique pos-sibilities and efficient solutions for implementation of the most complicated projects . The SSTenergomontazh con-sistently implements the Import Substitution Program of-fering high-quality and reliable systems of domestic man-ufacture to Russian customers .
For the time of the company’s work in the market of electri-cal heating systems, the specialists of the SSTenergomon-tazh engineering company have designed and installed over 4 thousand electrical heating systems for open areas and roofs, over 6 thousand heat tracing systems for pipe-lines and tanks . The total length of the pipelines heated by our systems exceeds 20 thousand kilometers .
The heat tracing systems for pipelines and tanks designed and installed by the SSTenergomontazh engineering company are operating on site objects of Gazprom, Lu-koil, Rosneft, Bashneft, Tatneft, Transneft, Alrosa and many other Russian and foreign companies .
The SSTenergomontazh is the member of the Special Sys-tems and Technologies Company Group (the SST Group) which is acting in the world market of electrical heating systems for over 20 years . The SST Group founded in 1991 is one of world leaders in the field of development and manufacture of industrial electric cable heating systems .
The factories of the SST Group located in the Moscow area form the largest in Europe complex of heating cables and temperature control equipment production .
Since the founding, about 1 million km of heating cables, over 5 million pieces of temperature control equipment and more than 10 million electrical heating systems of various purpose have been manufactured by the SST Group plants .
On the basis of the R&D center of the SST Group, study of parameters and development of heating elements design and control algorithms is performed . A wide range of heat-ing cables of various types, heating sections, temperature control and switchgear equipment is developed and im-plemented into industrial production in the SST Group .
Products of the SST Group are presented over the whole territory of Russia and exported to more than 40 coun-tries in the world, including Germany, France, Great Brit-ain, China, Brazil .
In 2004 the SST Group has implemented and certified a quality management system according to ISO 9001:2000 standard . Continuous multistage quality control of the in-dustrial electrical heating systems manufactured by the SST Group factories and constant improvement of pro-duction processes allow the SST Group production to sur-pass foreign analogues by performance and consumer properties . In 2013 the unified quality management sys-tem of the SST Group has been successfully evaluated under requirements of new standard versions of ISO 9001:2008 and GOST ISO 9001-2011 .
The high quality of the GSST Group production is con-firmed by appropriate certificates and permits and con-sistent with all Russian and international explosion, elec-trical and fire safety requirements .
The electric cable heating systems are a modern, conven-ient, flexible and cost effective tool to maintain the re-quired temperature mode on various objects . The advan-tages of such systems are low material consumption, simple installation, corrosion resistance and automatic control, which ensure keeping of optimal temperature conditions with the required accuracy and according to the preprogrammed time schedules . The SSTenergomon-tazh Company offers the most suitable solutions based on modern scientific developments and market trends .
The content of a cable heating system depends on its function (de-icing, temperature maintenance, warming up), location and specification of the object and is per-formed within the shortest possible time based on the data provided in questionnaires . The SSTenergomontazh offers to its customers the complete range of the SST Group product range: self-regulating and resistive heat-ing cables of various power, mineral-insulated cables, SKIN-systems for heating of ultra-long pipelines . The tem-perature control and monitoring is arranged by various units (sensors, controllers, control cabinets .
We are confident that perfect engineering solutions cus-tomized to suit your specific applications ensure uninter-rupted operation of industrial equipment, proper func-tioning of electrical installations at factories, efficient service of architectural and construction objects .
About the company
5
Ab
out
the
com
pan
y
6
Com
plete engineering
Basic estimationThe basic estimation is carried out to assess the neces-sary investment volume to implement the project . The equipment is preliminary selected and approximate works cost is calculated in the frame of the basic estima-tion . The basic estimation is performed free of charge and presented as Technical and Commercial Proposal .
The results of the preliminary stage are corrected in the process of precise object-oriented design work carried out basing on detailed technical data of the Customer .
Complete engineering
The SSTenergomontazh engineering company, the member of the Special Systems and Technologies Company Group offers full range of services in the area of industrial electrical heating and thermal insulation .
Design work and designer technical supervisionThe Company has its specialized engineering depart-ment, which draws up top level design-and-engineer-ing documents . We develop industrial electrical heating systems, thermal insulation and power supply systems (power cables, control cabinets) for different purposes including use in explosion hazard areas .
The design work is carried out in accordance with the operating Russian standards using up-to-date software and high-precision thermo-technical calculations simu-lating thermal processes .
After design and estimation documents are approved, SSTenergomontazh, by agreement with the customer, performs designer supervision to secure the compli-ance of construction and architecture parameters with the design solutions . We control all the project construc-tion stages from initial phase to object commissioning thus ensuring the maximum quality of the works per-formed and immediate solution of problems arising in the course of construction .
7
Com
ple
te e
ngin
eeri
ng
Delivery of equipmentThe SSTenergomontazh supplies equipment complex for electrical heating systems and thermal insulation . Smoothly running cooperation with production depart-ment, company’s own warehouse provided with con-stant replenishment enables us to offer our Customers the minimum delivery time . Subject to agreement with the Customer we implement product reservation at the warehouse and cargo delivery to Customer’s warehouse or site object where the equipment is going to be in-stalled .
InstallationOur specialists perform turnkey equipment installation . We implement the installation and tune-up of electrical heat-ing systems, general electric installation works, equipment start-up and commissioning with subsequent handover to the operating company and installation of thermal insula-tion . High quality of installation is ensured by vast experi-ence and highest professional qualification of our special-ists having permits to work with electrical installations up to and over 1000 V, V (fifth) and IV (forth) electrical safety group skill levels and certified against safety rules of work-ing at heights . Specialists of the SSTenergomontazh carry out trainings and certification of the contractor’s employ-ees dealing with electrical heating system installation .
Warranty serviceOur specialists consult Customers at any project stage concerning electrical heating system operation and go to the site object to control the system running, if needed . We are sure of the quality of our equipment and offer warranty extension and electrical heating system service even after warranty period expiry . The SSTenergomon-tazh has mobile service group to carry out warranty and support services, which gets to the object site within the shortest possible time .
Our service range includes diagnostics of electrical equip-ment, warranty and post-warranty service of the installed equipment and systems, training of operating personnel and technical support .
8
Explosion hazardous areas (according to G
OST, IEC and PU
E)
Zone 2
Zone 1Zone 1
Zone 0 Zone 0
Zone 0
Zone 1
Zone 2
a = 3 m from ventilation openingsb = 3 m above the roofc = 3 m in horizontal direction from the tank
Explosion hazardous areas (according to GOST, IEC and PUE – Electrical Installation Code)
What is a hazardous area?In terms of petrochemical industry, a hazard-ous area may be defined as «an object loca-tion where ambient atmosphere is likely to contain highly inflammable gases or vapors under normal operating conditions” .
In order to prevent ambient air-gas mixture combustion due to an accidental spark or contact with a heated surface, special measures are taken for all electric devices to be installed in hazardous areas . These special precautions should be considered as protective only un-der standard operating conditions; in case of emergency (such as an explosion or detonation) they are not expect-ed to ensure the same safety level .
Explosion or fire mostly occurs as a result of combination of three key factors referred to as a “risk triangle” . To make the explosive material catch fire, all three factors are to be available .
Probability of explosion hazardous gas and vapor presence
Properties of explosion hazardous atmosphere
Zone 0 – explosion hazardous mixture leaks permanently or for a long time
Zone 1 – explosion hazardous mixture leakage of grade 1 – appears from time to time or occasionally under the standard mode of equipment operation
Zone 2 – explosion hazardous mixture leakage of grade 2 – does not appear under the standard mode of equipment operation or appears for a short time
Т1 over 450 °С
Т2 from 300 to 450 °С
Т3 from 200 to 300 °С
Т4 from 135 to 200 °С
Т5 from 100 to 135 °С
Т6 from 85 to 100 °С
II А – MIC is over 0 .9 A
II В – MIC is ranging between 0 .5 A and 0 .9 A
II C – MIC is less than 0 .4 A
Explosion hazardous mixture category as per minimum ignition current (MIC) or maximum experimental safe gap (MESG)
Explosion hazardous medium group as per self-ignition temperature
Classification of hazardous areas as per GOST R IEC 60079-0-2011
ASSESSMENT OF EXPLOSION HAZARDOUS AREAS AS PER GOST
Combustible substances can be present as a gas, vapor or dust .
Oxygen is present in most cases since its volumetric con-tent in air makes up to 21% .
Igniter – sparks or heated surfaces may potentially cause an ignition .
Fire development or explosion may occur, if dust, gas or vapor concentration in air is between upper and lower combustion limits and the igniter has sufficient energy or tempera-ture .
COM
BUST
IBLE
SU
BSTA
NCE
S
AIR / OXYG
EN
IGNITER
9
Expl
osio
n ha
zard
ous
area
s (a
ccor
ding
to G
OST
, IEC
and
PUE)
CLASSIFICATION OF EXPLOSION HAZARDOUS ZONES ACCORDING TO ELECTRICAL INSTALLATION CODE
CORRELATION OF CLASSIFICATIONS OF EXPLOSION HAZARDOUS ZONES AS PER PROBABLE PRESENCE OF EXPLOSION HAZARDOUS MIXTURES AS PER GOST 60079 AND ELECTRICAL INSTALLATION CODE (PUE)
Explosion hazardous zone category shows how easy an explosive atmosphere can be inflamed by a spark or arc . Temperature classification or T class takes into account the inflammation effect due to a contact with a heated surface . Each gas and vapor features its individual self-ignition temperature, which is to be reached to cause self-ignition .
Explosion hazardous zone
CategoryCharacteristic gas, mixture
II Industrial gases and vapors
II A Acetone, propane, gasolines, crude oil
II B Ethylene, winter diesel fuel
II C Hydrogen, acetylene
According to GOST Zone 0 Zone 1 Zone 2
According to PUE
B-I, В-II B-Ia
B-Ig
B-Ib, В-IIa
Zone class Characteristics
В-IZones located in premises where combustible gases or vapors of inflammable liquids are generated in the amount and with the properties capable of producing explosion hazardous mixtures under standard operational conditions .
В-IаZones located in premises where explosion hazardous mixtures of combustible gases or vapors of inflammable liquids are not produced under standard operational conditions but may be originated as a result of emergency or malfunctions .
В-Iб
Zones located in premises where explosion hazardous mixtures of combustible gases or vapors of inflammable liquids are not produced under standard operational conditions but may be originated as a result of emergency or malfunctions; these explosion hazardous mixtures feature high explosive limit and strong smell .
В-IгZones located nearby outdoor installations containing combustible gases or inflammable liquids and spaces outside openings in outer walling of the premises which house explosion hazardous zones of В-I, B-Ia and B-II classes .
В-II Premises areas where combustible dusts and fibers capable of forming explosion hazardous mixtures with air are produced under standard operational conditions .
В-IIа Premises areas where combustible dusts and fibers capable of producing explosion hazardous mixtures with air are only generated as a result of emergency or malfunctions .
Classification of explosion hazardous mixtures as per maximum experimental safe gap and self-ignition temperature of Electrical Installation Code (PUE) is similar to that of GOST 60079 .
1
Relative probability
10-1 10-3 10-5
10
Explosion hazard and explosion protected electric equipm
ent
Explosion hazard and explosion protected electric equipment
Explosion protected electrical equipment is the electrical equipment featuring certain design solutions intended to prevent or hinder probable inflammation of the surrounding explosive atmosphere caused by operation of this equip-ment .
Explosion protected electrical equipment shall be installed in the potentially explosion hazardous areas; the equipment design and characteristics shall correspond to the explosion hazardous area class and explosive mixture characteristics .
Depending on its application field the explosion protected electrical equipment is divided into the following groups (GOST R IEC 60079-0-2011):
Group symbol Application field
I Explosion protected mine electrical equipment intended for use in underground workings of mines susceptible to firedamp and/or combustible dust
II Explosion protected electrical equipment for indoor and outdoor installation, intended for potentially explosive atmospheres, except of underground workings of mines susceptible to firedamp and/or dust
Depending on its explosion protection level, explosion protected electrical equipment for indoor and outdoor installa-tion is rated as follows (GOST R IEC 60079-0-2011):
Level symbol Explosion protection level Description
2Electrical equipment with improved explosion protection
Explosion-protected electrical equipment, which is only protected against explosion in recognized normal operation mode .
1 Explosion-proof electrical equipment
Explosion-protected electrical equipment which is protected against explosion both in recognized normal operation mode and in case of recognized probable damages caused by operational conditions except for damages of explosion protection facilities .
0 Extra-explosion-proof electrical equipment
Explosion-protected electrical equipment featuring, as compared to explosion-proof equipment, additional explosion protection measures specified by standards of explosion protection types .
Explosion proof electrical equipment of group II is divided into subgroups with regard to category of an explosive mix-ture, against which electric equipment is protected:
Electrical equipment group symbol Subgroup character Category of an explosive mixture against which electrical
equipment is protected
II
– IIА, IIВ, IIС
IIА IIА
IIВ IIА, IIВ
IIC IIА, IIВ, IIС
11
Expl
osio
n ha
zard
and
exp
losi
on
prot
ecte
d el
ectr
ic e
quip
men
t
CLASSIFICATION WITH REGARD TO SELF-IGNITION TEMPERATURE AND MAXIMUM PERMISSIBLE SURFACE TEMPERATURE OF THE EQUIPMENT
Temperature class
Self-ignition temperature, °С
Typical gas, mixture
Maximum surface temperature, °С
Temperature class of explosive mixture against which electrical equipment is
protected
Т1 From 450 Acetone, hydrogen, propane 450 Т1
Т2 From 300 to 450 Butane, spirits, acetylene 300 Т1 .Т2
ТЗ From 200 to 300 Gasolines, kerosenes, turpentine, oil 200 Т1 .Т2 .ТЗ
Т4 From 135 to 200 Acetaldehyde, diethyl ester 135 Т1 .Т2, ТЗ .Т4
Т5 From 100 to 135 Carbon bisulphide 100 Т1,Т2,ТЗ,Т4, Т5
Т6 From 85 to 100 85 Т1,Т2, ТЗ .Т4, Т5 .Т6
ELECTRICAL EQUIPMENT EXPLOSION PROTECTION LEVELS
The following types of explosion protection are used to ensure explosion protection of equipment depending on its design variations:
Level symbol Explosion protection level Allowed type of explosion protection
0Extra-explosion-proof
electrical equipment with explosion protection
ensured by:
Explosion protection of «i» type with spark-proof electrical circuit of «ia» level;
Special explosion protection of «s» type
1Electrical equipment with
explosion protection ensured by:
Explosion protection of «i» type with spark-proof electrical circuit of «ib» level at least
Explosion protection of «d» type – explosion-proof enclosure;
Special explosion protection of «s» type
Protection of «e» type if the electrical equipment has an explosion proof enclosure
Special explosion protection of «s» type
Types of explosion protection allowed for the level 0
2Electrical equipment
with improved explosion protection ensured by:
Explosion protection of «i» type with spark-proof electrical circuit of «ic» level and higher
Explosion protection of «d» type – for equipment with increased explosion-proof rating
Explosion protection of «q» type – powder filling of the enclosure
Explosion protection of «m» type – compound encapsulation
Explosion protection of «e» type
Special explosion protection of «s» type
Types of explosion protection allowed for the levels 0 and 1
12
Heating
cable selection
Heating cable selection
NOTE
We suggest using software to carry out thermal calculations and obtain a preliminary technical design and equipment specifications .
Value from Table1 on page 12
Heat conductivity factor, W/m•°С
Correction factor К1
0,025 – 0,035 0,6
0,035 – 0,045 0,8
0,045 – 0,055 1
0,055 – 0,07 1,2
Pipe location Correction factor К2
Outdoors 1
Indoors 0,9
Pipe material
Correction factor К3
Metal 1
Plastic 0,7
Heating cable type
Required safety factor EWith regard to additional cable consumption for fittings and supports / without regard to cable consumption for
fittings and supports
Self-regulating cable 1,1 / 1,2
Constant wattage cable 1,2 / 1,36
Qtotal = Qtable × К1 × К2 × КЗ × Е
3. When selecting a heating cable, the following factors are to be taken into consideration: maximum allowable temperature for the given cable type, cable heat output at maintained temperature, maximum maintenance temperature for the cable, correction factor of power supply voltage and heated area classification as well as probable availability of chemically active substances affecting the cable (see technical data sheets of the specific cables and accessories for details) .
In order to choose the type and model of a heating cable correctly, it is necessary to carry out thermal calculation . The calculation shall be performed for each separate pipeline .
1. Heat losses from the pipeline surface are estimated . The calculation may be carried out as per method exemplified below using a heat loss calculation table, which contains standard estimated heat losses from the pipeline surface with regard to the pipeline diameter, temperature difference between the pipeline and the environment and heat insulation thickness . The calculations presented in the table are made under the following conditions: heat insulation with heat conductivity factor equal to 0,05 W/m•°С is used .
2. If the conditions change, it is necessary to introduce the following corrections:
Total heat losses of a pipeline are determined as Qtotal
13
Hea
ting
cab
le s
elec
tion
Table 1 Estimated heat losses, Qv, W/m (assuming heat conductivity factor of heat insulation being equal to 0.05 W/(m∙°С))
Pipe diameter, mm 25 32 57 76 89 108 114 159 219 273 325 377 426 530 630 720 820 920 1020
∆Т, °С
Heat insulation thickness 20 mm
20 6,24 7,33 11,1 13,91 15,82 18,61 19,48 26,05 34,77 42,62 50,16 57,71 64,81 79,9 94,4 107,44 121,94 136,42 150,92
30 9,36 10,99 16,65 20,87 23,73 27,91 29,22 39,07 52,16 63,92 75,24 86,56 97,22 119,85 141,59 161,17 182,9 204,64 226,38
40 12,48 14,66 22,2 27,82 31,64 37,21 38,97 52,09 69,55 85,23 100,32 115,41 129,63 159,79 188,79 214,89 243,87 272,85 301,84
50 15,6 18,32 27,74 34,78 39,55 46,51 48,71 65,11 86,93 106,54 125,4 144,26 162,03 199,74 235,99 268,61 304,84 341,06 377,3
60 18,72 21,98 33,29 41,73 47,47 55,82 58,45 78,14 104,32 127,85 150,48 173,12 194,44 239,69 283,19 322,33 365,81 409,27 452,76
80 24,96 29,31 44,39 55,64 63,29 74,42 77,93 104,18 139,09 170,46 200,64 230,82 259,26 319,59 377,59 429,78 487,74 545,7 603,67
100 31,2 36,64 55,49 69,55 79,11 93,03 97,41 130,23 173,87 213,08 250,8 288,53 324,07 399,48 471,98 537,22 609,68 682,12 754,59
Heat insulation thickness 30 mm
20 4,97 5,75 8,4 10,36 11,68 13,61 14,21 18,73 24,72 30,1 35,27 40,44 45,31 55,64 65,57 74,5 84,42 94,34 104,26
30 7,46 8,63 12,6 15,54 17,53 20,41 21,32 28,09 37,08 45,15 52,91 60,66 67,97 83,46 98,35 111,75 126,63 141,5 156,38
40 9,95 11,5 16,81 20,72 23,37 27,21 28,42 37,46 49,44 60,2 70,55 80,88 90,62 111,28 131,13 148,99 168,83 188,67 208,51
50 12,44 14,38 21,01 25,9 29,21 34,02 35,53 46,82 61,81 75,25 88,18 101,1 113,28 139,1 163,91 186,24 211,04 235,84 260,64
60 14,92 17,25 25,21 31,08 35,05 40,82 42,63 56,19 74,17 90,3 105,82 121,33 135,93 166,91 196,7 223,49 253,25 283,01 312,77
80 19,9 23 33,61 41,44 46,73 54,43 56,85 74,92 98,89 120,4 141,09 161,77 181,24 222,55 262,26 297,99 337,67 377,34 417,02
100 24,87 28,76 42,01 51,8 58,42 68,03 71,06 93,65 123,61 150,5 176,36 202,21 226,55 278,19 327,83 372,49 422,09 471,68 521,28
Heat insulation thickness 40 mm
20 4,28 4,9 6,97 8,48 9,5 10,98 11,45 14,9 19,48 23,58 27,52 31,45 35,16 43,01 50,56 57,35 64,9 72,44 79,98
30 6,42 7,35 10,46 12,73 14,26 16,47 17,17 22,36 29,22 35,37 41,27 47,18 52,73 64,52 75,84 86,03 97,34 108,66 119,97
40 8,57 9,8 13,94 16,97 19,01 21,96 22,89 29,81 38,96 47,15 55,03 62,9 70,31 86,02 101,12 114,71 129,79 144,88 159,96
50 10,71 12,25 17,43 21,21 23,76 27,45 28,61 37,26 48,69 58,94 68,79 78,63 87,89 107,53 126,4 143,38 162,24 181,09 199,95
60 12,85 14,69 20,91 25,45 28,51 32,95 34,34 44,71 58,43 70,73 82,55 94,35 105,47 129,04 151,68 172,06 194,69 217,31 239,94
80 17,13 19,59 27,88 33,94 38,02 43,93 45,78 59,61 77,91 94,31 110,06 125,8 140,62 172,05 202,25 229,41 259,59 289,75 319,92
100 21,41 24,49 34,85 42,42 47,52 54,91 57,23 74,52 97,39 117,88 137,58 157,25 175,78 215,06 252,81 286,77 324,48 362,19 399,9
Heat insulation thickness 50 mm
20 3,84 4,36 6,07 7,32 8,15 9,36 9,73 12,54 16,25 19,57 22,75 25,93 28,92 35,27 41,36 46,84 52,93 59,01 65,09
30 5,76 6,53 9,11 10,97 12,23 14,03 14,6 18,82 24,38 29,35 34,13 38,9 43,38 52,9 62,04 70,26 79,39 88,51 97,64
40 7,68 8,71 12,15 14,63 16,3 18,71 19,47 25,09 32,5 39,14 45,5 51,86 57,85 70,53 82,72 93,68 105,85 118,02 130,19
50 9,6 10,89 15,18 18,29 20,38 23,39 24,34 31,36 40,63 48,92 56,88 64,83 72,31 88,16 103,4 117,1 132,31 147,52 162,74
60 11,52 13,07 18,22 21,95 24,45 28,07 29,2 37,63 48,75 58,7 68,26 77,79 86,77 105,8 124,08 140,52 158,78 177,03 195,28
80 15,36 17,42 24,29 29,27 32,6 37,43 38,94 50,18 65 78,27 91,01 103,72 115,69 141,06 165,43 187,36 211,7 236,04 260,38
100 19,2 21,78 30,37 36,58 40,75 46,78 48,67 62,72 81,26 97,84 113,76 129,65 144,61 176,33 206,79 234,2 264,63 295,05 325,47
Heat insulation thickness 60 mm
20 3,53 3,98 5,45 6,51 7,22 8,25 8,57 10,94 14,06 16,85 19,53 22,19 24,71 30,03 35,14 39,73 44,83 49,93 55,03
30 5,29 5,96 8,18 9,77 10,84 12,37 12,85 16,41 21,09 25,28 29,29 33,29 37,06 45,04 52,7 59,6 67,25 74,9 82,55
40 7,06 7,95 10,91 13,03 14,45 16,49 17,13 21,88 28,12 33,7 39,05 44,39 49,41 60,05 70,27 79,46 89,67 99,87 110,07
50 8,82 9,94 13,63 16,29 18,06 20,62 21,42 27,35 35,15 42,13 48,81 55,49 61,76 75,07 87,84 99,33 112,08 124,83 137,58
60 10,58 11,93 16,36 19,54 21,67 24,74 25,7 32,82 42,19 50,55 58,58 66,58 74,12 90,08 105,41 119,19 134,5 149,8 165,1
80 14,11 15,9 21,82 26,06 28,9 32,99 34,27 43,76 56,25 67,4 78,1 88,78 98,82 120,1 140,54 158,92 179,33 199,73 220,13
100 17,64 19,88 27,27 32,57 36,12 41,23 42,83 54,7 70,31 84,25 97,63 110,97 123,53 150,13 175,68 198,65 224,17 249,67 275,16
Heat insulation thickness 80 mm
20 3,11 3,47 4,65 5,48 6,03 6,82 7,07 8,89 11,27 13,4 15,43 17,45 19,36 23,39 27,25 30,73 34,58 38,44 42,29
30 4,67 5,21 6,97 8,21 9,04 10,23 10,6 13,33 16,91 20,09 23,14 26,18 29,03 35,08 40,88 46,09 51,88 57,66 63,44
40 6,22 6,95 9,29 10,95 12,06 13,64 14,13 17,78 22,55 26,79 30,86 34,91 38,71 46,77 54,5 61,45 69,17 76,88 84,59
50 7,78 8,68 11,62 13,69 15,07 17,05 17,67 22,22 28,18 33,49 38,57 43,63 48,39 58,46 68,13 76,82 86,46 96,1 105,74
60 9,33 10,42 13,94 16,43 18,08 20,46 21,2 26,67 33,82 40,19 46,28 52,36 58,07 70,16 81,76 92,18 103,75 115,32 126,88
80 12,44 13,89 18,58 21,91 24,11 27,28 28,26 35,56 45,1 53,59 61,71 69,81 77,42 93,54 109,01 122,91 138,34 153,76 169,18
100 15,55 17,36 23,23 27,38 30,14 34,1 35,33 44,45 56,37 66,98 77,14 87,26 96,78 116,93 136,26 153,64 172,92 192,2 211,47
Heat insulation thickness 100 mm
20 2,84 3,15 4,14 4,83 5,28 5,93 6,14 7,63 9,57 11,29 12,93 14,56 16,1 19,35 22,46 25,26 28,36 31,46 34,56
30 4,26 4,72 6,2 7,24 7,92 8,9 9,2 11,44 14,35 16,93 19,39 21,85 24,15 29,02 33,69 37,89 42,54 47,19 51,84
40 5,68 6,3 8,27 9,65 10,57 11,87 12,27 15,25 19,13 22,57 25,86 29,13 32,2 38,69 44,92 50,51 56,72 62,92 69,12
50 7,1 7,87 10,34 12,07 13,21 14,83 15,34 19,07 23,92 28,21 32,32 36,41 40,25 48,37 56,15 63,14 70,9 78,65 86,4
60 8,52 9,45 12,41 14,48 15,85 17,8 18,41 22,88 28,7 33,86 38,79 43,69 48,3 58,04 67,38 75,77 85,08 94,38 103,68
80 11,36 12,59 16,54 19,31 21,13 23,73 24,55 30,51 38,26 45,14 51,72 58,26 64,4 77,39 89,84 101,03 113,44 125,85 138,24
100 14,2 15,74 20,68 24,13 26,41 29,67 30,68 38,14 47,83 56,43 64,64 72,82 80,5 96,73 112,3 126,28 141,8 157,31 172,8
Heat insulation thickness 150 mm
20 2,84 2,67 3,41 3,91 4,24 4,7 4,84 5,89 7,23 8,41 9,53 10,64 11,68 13,88 15,98 17,87 19,96 22,05 24,13
30 4,26 4,01 5,11 5,86 6,35 7,05 7,26 8,83 10,84 12,61 14,29 15,96 17,53 20,82 23,98 26,81 29,94 33,07 36,2
40 5,68 5,35 6,81 7,82 8,47 9,4 9,68 11,77 14,46 16,82 19,06 21,28 23,37 27,76 31,97 35,74 39,92 44,09 48,26
50 7,1 6,69 8,52 9,77 10,59 11,75 12,1 14,71 18,07 21,02 23,82 26,61 29,21 34,71 39,96 44,68 49,9 55,12 60,33
60 8,52 8,02 10,22 11,72 12,71 14,09 14,52 17,66 21,68 25,22 28,59 31,93 35,05 41,65 47,95 53,61 59,88 66,14 72,39
80 11,36 10,7 13,63 15,63 16,94 18,79 19,37 23,54 28,91 33,63 38,12 42,57 46,74 55,53 63,94 71,48 79,84 88,19 96,52
100 14,2 13,37 17,04 19,54 21,18 23,49 24,21 29,43 36,14 42,04 47,65 53,21 58,42 69,41 79,92 89,35 99,8 110,24 120,66
STANDARD ESTIMATION OF HEAT LOSS FROM THE SURFACE OF PIPELINE
14
Calculation of p
ipeline
cooling tim
e
The primary purpose of the TEPLOMAG electrical heating systems is the maintenance of the required temperature of the heated pipelines by means of heat loss compensation . However, if scheduled or emergency repair works are necessary, the power supply may be switched off .
When disconnected from power supply, the pipeline heating system does not compensate the heat loss into the environment . The interruption of power supply will cause the pumps to stop as well . Liquid pumping will be brought to a standstill .
The pipeline will start gradual cooling . Pipelines filled with liquid and covered with heat insulation feature essential thermal inertia . The more the diameter of the pipe, and the higher the allowed cooling degree, the higher the thermal inertia is .
Operating team and maintenance department need to know the maximum allowed time period of pipeline heating system power outage . The below tables present the results of cooling time calculations made for a number of standard pipelines with drift diameter from 50 to 400 mm . Cases are considered when the pipeline is completely filled with water or oil . The pipes are covered with heat insulation made of mineral wool with the heat conductivity factor equal to 0,05 W/m•°С . The input data used in calculation are given in Table 1 .
Table 1Input data
Liquid Density, kg/m3
Thermal capacitance, J/kg•°С
Т initial, °С
Т final, °С
Air temperature range, °С
Oil 852 1900 50 20 –50 . . . 20
Water 1000 4200 8 2 –50 . . . 0
Table 2Cooling time of the pipeline with oil from +50 to +20 °С
D, mm
Douter, mm
Δ insulation, mm
ρ insulation, kg/m3
Air temperature, °С
-50 -40 -30 -20 -10 0 10 15 20
50 58 30 80 1,1 1,2 1,4 1,6 2,0 2,6 3,8 5,2 8,8
80 89 40 80 2,1 2,4 2,8 3,3 4,1 5,3 7,8 10,5 17,8
100 114 50 90 3,5 4,0 4,6 5,5 6,7 8,8 12,9 17,3 29,5
150 168 50 90 5,4 6,1 7,0 8,3 10,2 13,3 19,6 26,3 44,8
200 219 60 100 8,4 9,5 11,0 13,0 16,0 20,9 30,6 41,1 70,0
250 273 60 100 10,6 12,1 13,9 16,5 20,3 26,5 38,9 52,1 88,9
300 324 80 100 16,5 18,7 21,6 25,6 31,5 41,1 60,3 80,8 138
400 430 100 100 27,4 31,1 36,8 42,5 52,3 68,2 100 134 229
Color code:
– less than 2 hours, – from 2 to 3 hours, – from 3 to 6 hours,
– from 6 to 12 hours, – from 12 to 24 hours, – more than 24 hours .
Table 2 illustrates the results of pipe cooling time calculation, if it is filled with medium density oil, depending on the ambient air temperature . Heat insulation thickness and its density are stated along with pipe dimensions . Oil temperature at the moment of power supply outage makes up 50 °C . It is assumed that the minimum temperature to which oil can be cooled is 20 °C . The Table shows the dependencies of the pipe cooling time both on characteristics of pipes and heat insulation and on ambient air temperature . Naturally, the higher the ambient air temperature, the longer the period of pipe cooling down .
Calculation of pipeline cooling time
15
Calc
ulat
ion
of p
ipel
ine
cool
ing
tim
e
Table 3Cooling time of the pipeline 150 mm in diameter filled with oil with varying heat insulation thickness.
Table 4Cooling time of the pipeline with water from +8 to +2 °С.
D, mm
Douter, mm
Δ insulation, mm
ρ insulation, kg/m3
Air temperature, °С
-50 -40 -30 -20 -10 0 10 15 20
150 168 30 90 3,4 3,8 4,4 5,3 6,5 8,4 12,4 16,6 28,3
150 168 40 90 4,4 5,0 5,8 6,8 8,4 10,9 16,0 21,5 36,7
150 168 50 90 5,4 6,1 7,0 8,3 10,2 13,3 19,6 26,3 44,8
150 168 60 90 6,3 7,2 8,3 9,8 12,0 15,7 23,0 30,9 52,7
D, mm
Douter, mm
Δ insulation, mm
ρ insulation, kg/m3
Air temperature, °С
-50 -40 -30 -20 -10 -5 0
50 58 30 80 0,55 0,67 0,86 1,2 2,0 3,0 6,5
80 89 40 80 1,23 1,50 1,93 2,7 4,5 6,8 14,5
100 114 50 90 1,92 2,35 3,0 4,2 7,0 10,6 22,7
150 168 50 90 3,1 3,8 4,9 6,8 11,4 17,1 36,6
200 219 60 100 5,1 6,2 8,0 11,2 18,6 28,1 60,0
250 273 60 100 6,6 8,0 10,3 14,4 24,1 36,3 77,5
300 324 80 100 10,4 12,7 16,3 22,8 38,0 57,4 122,6
400 430 100 100 17,5 21,4 27,4 38,4 64,0 96,6 206,0
Table 3 exemplifies the dependence of the cooling time on the heat insulation thickness . The calculation is performed for pipeline 150 mm in diameter filled with oil . The heat insulation thickness was varying from 30 to 60 mm . The twofold increase of heat insulation thickness leads to twofold increase of cooling time . This method can be used to prolong the pipeline cooling time .
Table 4 presents the time periods of cooling down of the pipeline filled with water . The water temperature in a heated pipeline in cold season is usually maintained at 5–8 °C, water cooling down below 2 °C is not acceptable . Structure of the Table 4 is similar to that of Table 2 . In spite of the fact that heat content of 1 kg of water is 2,6 times more than that of 1 kg of oil, the smaller allowable range of temperature fall causes the decrease in allowable cooling time periods . .
Color code:
– less than 2 hours, – from 2 to 3 hours, – from 3 to 6 hours,
– from 6 to 12 hours, – from 12 to 24 hours, – more than 24 hours .
Color code:
– from 3 to 6 hours, – from 6 to 12 hours, – from 12 to 24 hours, – more than 24 hours .
17
Industrial heating systems
18
Industrial heating
systems
HTMSelf-regulating electrical heating tape for freeze protection or temperature maintenance of pipelines and vessels in safe and hazardous areas .
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
Full range of controls and accessories
Approved for use in safe, hazardous and corrosive environments
Ideal for fitting to equipment and small-diameter pipes
Operating voltage 220–240 VAC (110–120 VAC on request)
1 2
3 4
5
1. 0 .56 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Thermoplastic elastomer insulation
4. Tinned copper braid
5. Optional outer jacket
FeaturesHTM is an industrial grade self-regulating heating tape that can be used for freeze protection or temperature maintenance of pipelines and vessels .
It is particularly suited for small-diameter pipes and equip-ment such as impulse and analyzer lines not subject to steaming .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
HTM is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and relia-bility . HTM will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of HTM heating tape is quick and simple and requires no special skills or tools . Termination, splicing and power connection components are all provided in convenient kits .
Design optionsHTM...BТ Thermoplastic elastomer outer jacket over
tinned copper braid or combined braid ensures additional protection .
HTM...BP Fluoroplastic outer jacket over tinned copper braid provides protection where corrosive chemical solutions or vapors may be present .
19
Ind
ustr
ial h
eati
ng s
yste
ms
SELF-REGULATING ELECTRICAL HEATING TAPE
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Thermal ratingsNominal heat output at operating voltage 115 V or 230 V, when self-regulating heating tapes operate in normal conditions .
Technical data
Type Turn-on temperature, °С 230 V, 10 A
10HTM
10 100
0 95
-20 77
15HTM
10 72
0 66
-20 52
Maximum temperature 65 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 85 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (110–120 VAC on request) 220–240 VAC
Temperature classification Т6
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .
* The minimum bending radius at –20 °C is shown
Linear power output, W/m
Pipe temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
HTM . . .BT 10 .7×6 .3 10 .96 35
HTM . . .BP 10 .3×5 .9 11 .61 35
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements .
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
Ordering informationExample: 15HTM2-BT
Linear power output 15 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: HT – low temperatureTape design version: M – for small-diameter pipesSupply voltage: 1 – 110–120 VAC, 2 – 220–240 VACBraid material: B – tinned copper wireOuter jacket material: T – thermoplastic elastomer, P – fluoropolymer
24
22
20
18
16
14
12
10
8
6
4
2
0-20 -10 10 20 30 40 500
15HTM
10HTM
20
Industrial heating
systems
HTASelf-regulating electrical heating tape for freeze protection or temperature maintenance of pipelines and vessels in safe and hazardous areas
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
Full range of controls and accessories
Approved for use in safe, hazardous and corrosive environmentsх
Operating voltage 220–240 VAC (110–120 VAC on request)
1. 1 .0 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Thermoplastic elastomer insulation
4. Tinned copper braid
5. Optional outer jacket
FeaturesHTA is an industrial grade self-regulating heating tape that can be used for freeze protection or temperature maintenance of pipelines and vessels .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
Internal matrix insulation forming with it a single unit pro-vides additional protection against moisture .
HTA is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and reli-ability . HTA will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of HTA heating tape is quick and simple and requires no special skills or tools . Termination, splic-ing and power connection components are all provided in convenient kits .
Design optionsHTA...BТ Thermoplastic elastomer outer jacket over
tinned copper braid or combined braid ensures additional protection .
HTA...BP Fluoroplastic outer jacket over tinned cop-per braid provides protection where corro-sive chemical solutions or vapors may be present (available on order) .
1 2
3 4
5
21
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Technical data
Maximum temperature 65 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 85 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (110–120 VAC on request) 220–240 VAC
Temperature classification Т6
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .
* The minimum bending radius at –20 °C is shown .
Linear power output, W/m
Pipe temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
HTA . . .BT 10 .7×6 .3 10 .96 35
HTA . . .BP 10 .5×5 .9 11 .61 35
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements .
Ordering informationExample: 25HTА2 -BT
Linear power output 25 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: HT – low temperatureTape design version: A – for commercial useSupply voltage: 1 – 110–120 VAC, 2 – 220–240 VACBraid material: B – tinned copper wireOuter jacket material: T – thermoplastic elastomer, P – fluoropolymer
45
40
35
30
25
20
15
10
5
0-20 -10 10 20 30 40 500
25HTA
20HTA
15HTA
Type Turn-on temperature, °C
230 V
10 A 16 A
15HTА
10 104 136
-15 69 89
-20 58 78
20HTA
10 79 110
-15 49 71
-20 42 58
25HTA
10 60 83
-15 39 56
-20 32 47
Thermal ratingsNominal heat output at operating voltage 115 V or 230 V, when self-regulating heating tapes operate in normal conditions .
SELF-REGULATING ELECTRICAL HEATING TAPE
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
22
Industrial heating
systems
HTPSelf-regulating electrical heating tape for freeze protection or temperature maintenance of industrial pipelines and vessels in safe and hazardous areas
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
Full range of controls and accessories
Operating voltage 220–240 VAC (110–120 VAC on request)
1. 1 .24 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Thermoplastic elastomer insulation
4. Tinned copper braid
5. Optional outer jacket
FeaturesHTP is an industrial grade self-regulating heating tape that can be used for freeze protection or temperature maintenance of pipelines and vessels .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
HTP is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and reli-ability . HTP will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of HTP heating tape is quick and simple and requires no special skills or tools . Termination, splic-ing and power connection components are all provided in convenient kits .
Design optionsHTР...BТ Thermoplastic elastomer outer jacket over
tinned copper braid or combined braid ensures additional protection .
HTР...BP Fluoroplastic outer jacket over tinned cop-per braid provides protection where corro-sive chemical solutions or vapors may be present .
1 2
3 4
5
23
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Technical data
Maximum temperature 65 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 85 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (110–120 VAC on request) 220–240 VAC
Temperature classification Т6
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .
* The minimum bending radius at –20 °C is shown .
Linear power output, W/m
Pipe temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
HTР . . .BT 13 .15×6 .2 12 .97 25
HTР . . .BP 12 .75×5 .8 13 .76 25
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements .
Ordering informationExample: 33HTР2 -BT
Linear power output 33 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: HT – low temperatureTape design version: P – for commercial useSupply voltage: 1 – 110–120 VAC, 2 – 220–240 VACBraid material: B – tinned copper wireOuter jacket material: T – thermoplastic elastomer, P – fluoropolymer
45
40
35
30
25
20
15
10
5
0-20 -10 10 20 30 40 500
33HTP
25HTР
15HTР
10HTР
Tип Температура включения, °C
230 В
16 A 20 A 32 A 40 A
10HTР10 205 – – –-15 140 186 195 –-20 123 165 195 –
15HTР10 145 162 – –-15 93 125 160 –-20 82 111 160 –
25HTР10 88 117 126 –-15 60 75 117 125-20 50 70 105 125
33HTР10 70 90 108 –-15 50 65 95 105-20 45 58 85 105
Thermal ratingsNominal heat output at operating voltage 115 V or 230 V, when self-regulating heating tapes operate in normal conditions .
SELF-REGULATING ELECTRICAL HEATING TAPE
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
24
Industrial heating
systems
ВTСSelf-regulating electrical heating tape for freeze protection or temperature maintenance of industrial pipelines and vessels in safe and hazardous areas .
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
High power output – up to 60 W/m
Full range of controls and accessories
Operating voltage 220–240 VAC (110–120 VAC on request))
1. 1 .25 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Fluoroplastic insulation
4. Tinned copper braid
5. Fluoroplastic outer jacket
FeaturesBTC is an industrial grade self-regulating heating tape that can be used for freeze protection of large diameter pipelines undergoing steaming and temperature mainte-nance of industrial pipelines and vessels where tempera-ture up to 120 °C may exist and in systems with high heat-ing tape exposure temperature .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
BTC is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and reli-ability . BTC will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of BTC heating tape is quick and simple and requires no special skills or tools . Termination, splic-ing and power connection components are all provided in convenient kits .
Design optionsВTС...BP Fluoroplastic outer jacket over tinned cop-
per braid provides protection where corro-sive chemical solutions or vapors may be present .
1 2
3 4
5
25
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Technical data
Maximum temperature 120 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 190 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (110–120 VAC on request) 220–240 VAC
Temperature classification Т4
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .* The minimum bending radius at –20 °C is shown .
Linear power output, W/m
Pipe temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
ВTС . . .BP 12 .1×5 .4 15 .2 35
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements .
Ordering informationExample: 45ВTС2 -BР
Linear power output 45 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: BT – high temperatureTape design version: C – for industrial use Supply voltage: 1 – 110–120 VAC, 2 – 220–240 VACBraid material: B – tinned copper wireOuter jacket material: P – fluoropolymer
7570656055504540353025201510
50
-20-30-40 -10 10 20 30 40 50 60 70 80 90 100 1100
60ВTС
45ВTС
30ВTС
15ВTС
Type Turn-on temperature, °C
230 V
16 A 20 A 32 A
15ВTС10 165 189 –
-25 117 152 189
30ВTС10 85 114 –
-25 69 92 114
45ВTС10 70 82 –
-25 49 66 82
60ВTС10 50 64 –
-25 38 52 64
Thermal ratingsNominal heat output at operating voltage 115 V or 230 V, when self-regulating heating tapes operate in normal conditions .
SELF-REGULATING ELECTRICAL HEATING TAPE
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
26
Industrial heating
systems
ВTXSelf-regulating electrical heating tape for freeze protection or temperature maintenance of industrial pipelines and vessels in safe and hazardous areas
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
High power output – up to 95 W/m
Full range of controls and accessories
Operating voltage 220–240 VAC (110–120 VAC on request)
1. 1 .25 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Fluoroplastic insulation
4. Nickel plated copper braid
5. Fluoroplastic outer jacket
FeaturesBTX is an industrial grade self-regulating heating tape that can be used for freeze protection or temperature maintenance of industrial pipelines and vessels (and oth-er process equipment) as well as a component part of systems where high temperatures affect the heating tape .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
BTX is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and reli-ability . BTX will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of BTX heating tape is quick and simple and requires no special skills or tools . Termination, splic-ing and power connection components are all provided in convenient kits .
Design optionsВTX...BP Fluoroplastic outer jacket over nickel plated
copper braid provides protection where corrosive chemical solutions or vapors may be present .
Temperature resistance up to 250°C
1 2
3 4
5
27
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Technical dataMaximum temperature 190 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 250 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (110–120 VAC on request) 220–240 VAC
Temperature classification Т3
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .
* The minimum bending radius at –20 °C is shown .
Linear power output, W/m
Pipe temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
15ВTX . . .80ВTX 12 .1×5 .4 15 .2 30
95ВTX 14 .4×5 .5 19 .8 30
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements . .
Ordering informationExample: 45ВT X2 -BР
Linear power output 45 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: BT – high temperatureTape design version: X – for industrial useSupply voltage: 1 – 110–120 VAC, 2 – 220–240 VACBraid material: B – nickel plated copper wireOuter jacket material: P – fluoropolymer
110
100
90
80
70
60
50
40
30
20
10
0-20-30-40 -10 10 20 30 40 50 60 70 80 90 100 160 170 1801501401301201100
60ВTX
80ВTX
95ВTX
45ВTX
30ВTX
15ВTX
Type Turn-on temperature, °C
230 V
16 A 20 A 32 A
15ВTX10 110 146 165-20 99 131 165-40 88 117 165
30ВTX10 73 98 110-20 70 93 110-40 69 91 110
45ВTX10 49 64 82-20 43 56 82-40 37 49 73
60ВTX10 35 46 70-20 34 44 67-40 32 43 64
80ВTX10 27 37 52-20 24 30 49-40 24 30 49
95ВTX10 24 30 43-20 21 27 43-40 21 27 43
Thermal ratingsNominal heat output at operating voltage 115 V or 230 V, when self-regulating heating tapes operate in normal conditions .
SELF-REGULATING ELECTRICAL HEATING TAPE
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
28
Industrial heating
systems
HTВSelf-regulating electrical heating tape for freeze protection or temperature maintenance of industrial pipelines and vessels in safe and hazardous areas
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
Full range of controls and accessories
Approved for safe use in hazardous and corrosive areas
Operating voltage 22–24 V (11–12 V on request)
1. 1 .1 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Thermoplastic elastomer insulation
4. Tinned copper braid
5. Optional outer jacket
FeaturesHTB is an industrial grade self-regulating heating tape rated for light load that can be used to prevent freezing of pipes or to maintain the preset temperature of industrial pipelines and vessels in the construction and refrigera-tion industries as well as automobile transportation .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
HTB is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and reli-ability . HTB will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of HTB heating tape is quick and simple and requires no special skills or tools . Termination, splic-ing and power connection components are all provided in convenient kits .
Design optionsHTВ...BТ Thermoplastic elastomer outer jacket over
tinned copper braid or combined braid ensures additional protection .
HTВ...BP Fluoroplastic outer jacket over tinned copper braid provides protection where corrosive chemical solutions or vapors may be present .
1 2
3 4
5
29
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Thermal ratingsNominal heat output at operating voltage 12 V or 24 V, when self-regulating heating tapes operate in normal conditions .
Technical data
Type Turn-on temperature, °С
24 V
6 A 10 A 16 A
12HTВ
5 8 14 200 8 12 20-20 6 10 16-40 4 8 12
17HTВ
5 6 10 160 6 10 16-20 6 8 14-40 4 8 12
Maximum temperature 65 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 85 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (11–12 VAC on request) 22–24 V
Temperature classification Т6
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .
* The minimum bending radius at –20 °C is shown .
Linear power output, W/m
Pipe temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
HTВ . . .BT 10 .5×5 .9 10 .5 30
HTВ . . .BP 10 .5×5 .9 12 .0 30
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements .
Ordering informationExample: 12HTВ24-BT
Linear power output 12 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: HT – low temperatureTape design version: B – low voltageSupply voltage: 12 – 11–12 V, 22 – 22–24 VBraid material: B – tinned copper wireOuter jacket material: T – thermoplastic elastomer, P – fluoropolymer
25
20
15
10
5
0
-20-30-40 -10 10 20 30 40 50 60 700
17HTВ
12HTВ
SELF-REGULATING ELECTRICAL HEATING TAPE
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
30
Industrial heating
systems
CTESelf-regulating electrical heating tape for application in heating systems for open areas: pump shelters, open platforms, ramps, helicopter decks freeze protection or temperature maintenance of industrial pipelines and vessels in safe and hazardous areas .
Automatically adjusts heat output in response to increasing or decreasing pipe temperature
Can be cut to required length without damage to its properties
Will not overheat or burnout even if self-overlapped
High power output – up to 80 W/m
Full range of controls and accessories
Operating voltage 220–240 VAC (110–120 VAC on request)
1. 2 .0 mm2 Tinned copper conductors
2. Semi-conductive self-limiting matrix
3. Thermoplastic elastomer insulation
4. Tinned copper braid
5. Thermoplastic elastomer outer jacket
FeaturesCTE is an industrial grade self-regulating heating tape that can be used to prevent icing and snow cover forma-tion on industrial open areas .
It can be cut to length on site and exact piping length can be matched without any complicated design considera-tions .
CTE is certified for use in safe and explosion hazardous environments against international standards as well as GOST R 51330 and GOST R IEC 62086 standards .
Its self-regulating characteristics improve safety and reli-ability . CTE will not overheat or burnout even when over-lapped upon itself . The heat output adjusts automatically in response to temperature change .
The installation of CTE heating tape is quick and simple and requires no special skills or tools . Termination, splic-ing and power connection components are all provided in convenient kits .
Upon request, the heating tape can be supplied as facto-ry-made heating sections of SSBE and SMBE types, ready for connection .
Design optionsСTЕ...BТ Thermoplastic elastomer outer jacket over
tinned copper braid or combined braid ensures additional protection .
1 2
3 4
5
31
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum length of heating section, m(or overall length of sections of the same type, connected in parallel) vs circuit breaker type
Technical data
Maximum temperature 80 °С
Maximum allowable temperature de-energized (1000 hours cumulative) 100 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply (110–120 VAC on request) 220–240 VAC
Temperature classification Т6
Maximum resistance of the protective braid, not more than 10 Ohm/km
For use with type C circuit breakers according to GOST R 50345-2010 (IEC 60898-1:2003)
* An inrush current (starting current) appears at the moment of turning on the heating section . The current value stabilizes within 5 minutes after turning on . Maximum starting current can be 5–6 times higher than the rated current value of the circuit breaker .
* The minimum bending radius at –20 °C is shown .
Linear power output, W/m
Temperature, °С
Dimensions and weightsType Nominal
dimensions, mmWeight, kg/100 m
Minimum bending radius*, mm
СTЕ . . .BТ 16 .8×8 .2 22 .66 25
AccessoriesA range of accessories includes component parts for power supply, splice and termination of the heating tape and a control unit . We recommend using original accessories made by SST Company to ensure trouble-free operation and meeting safety standards and re-quirements .
Ordering informationExample: 80СTЕ2 -BT
Linear power output 80 W/m (according to IEC 60079-1-30)Type of self-regulating heating tape: CT – medium temperatureTape design version: E – for industrial useSupply voltage: 1 – 110–120 VAC, 2 – 220–240 VACBraid material: B – tinned copper wireOuter jacket material: T – thermoplastic elastomer
110
100
90
80
70
-10 -5 5 10 150
80СTЕ
Type Turn-on temperature, °C
230 V
25 A 30 A
80СTЕ0 63 76
-20 53 64
Thermal ratingsNominal heat output at operating voltage 115 V or 230 V, when self-regulating heating tapes operate in normal conditions .
SELF-REGULATING ELECTRICAL HEATING TAPE
Approval detailsCertificate of conformity IEC Ex for self-regulating heating tapes No . IECEx CCVE 12 .0002X .
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» TC RU C-RU .ГБ05В .0528 for self-regulating heating tapes with explosion protection marking 1Ex e llС T3 . . .T6 Gb X .
Certificate of Conformity to Technical Regulations on Fire Safety for self-regulating heating tapes No . С-RU .ПБ37 .В .01460 .
32
Industrial heating
systems
LLSConstant wattage electrical heating cable for heating of pipelines of medium length
Length of heated pipe runs up to 3 km
High power output – up to 50 W/m
High efficiency, developed surface of heat emission and flexibility
Full range of controls and accessories
Power supply from a single point minimizes costs for supply wiring
Easy and convenient installation
1 2 3 4
1. Heating cores of copper wires
2. Insulation of organic-silicon rubber
3. Tinned copper braid
4. Outer jacket of organic-silicon rubber
FeaturesConstructionThe heating cable structurally includes three parallel heating cores made of copper wire insulated with organ-ic-silicon rubber; the insulation is covered with tinned copper wire braid and organic-silicon rubber outer jacket .
Heating system arrangementSize of the heating conductors is selected to provide the desired power output for a specified length of the circuit . Heating cables are connected directly to three-phase power network or, if necessary, to a special step-up trans-former .
Enhanced efficiency and safetyConsiderable heated surface of the flat heating cable leads to decrease of operating temperatures in compari-son with similar heaters featuring round-shape conduc-tors thus improving safety and efficiency of the heating cable and prolonging its service life . Using organic-silicon rubber as an insulator, which is capable to maintain its electric and mechanical properties within the wide range of temperature, enables to get power output of the tape up to 50 W/m .
InstallationLLS cables may be laid on a pipe straightly or spirally . As for pre-insulated pipelines, the cables are as a rule placed in conduit elements fitted to a trunk pipe inside its thermal insulation .
The heating cable is available both as convenient for installation lengths for series connection on site and as ready-made heating sections TMTE . Cables to be installed at power supply point are delivered equipped with cold leads .
Minimum supply wiring costThe system application minimizes the required number of power supply points and, thus, reduces cost of power supply network arrangement .
33
Ind
ustr
ial h
eati
ng s
yste
ms
Maximum pipe / workpiece temperatureHeating cable surface temperature shall not exceed the maximum withstand temperatures of its constructional materials or that specified for the temperature classifica-tion (for installations in explosion hazardous areas) . This is ensured by limiting of power output of the heating cable depending on the pipe or workpiece temperature to a safe level either by design calculation or by means of tem-perature control system .
For worst heat transfer conditions, the temperature of the pipe should be limited to the following levels:
Technical data
Maximum workpiece temperature, °С
Nominal power output of the heating cable,
W/m
Area classification
Explosion hazardousSafe
Т6 Т5 Т4 Т3 Т2 Т1
5 55 70 100 100 100 100 100
10 50 65 95 95 95 95 95
20 30 45 75 75 75 75 75
25 20 35 70 70 70 70 70
30 10 25 55 55 55 55 55
35 – 15 45 45 45 45 45
40 – – 30 30 30 30 30
50 – – 5 5 5 5 5
Maximum temperature 130 °С
Maximum allowable temperature de-energized 180 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Power supply three-phase up to 660 VAC depending on application conditions
Power output up to 50 W/m, depending on design version for specified application conditions
Heating conductor cross section 1 .5; 3 .0; 6 .0 мм2
Please note that the manufacturer is entitled to modify the conductor sizes in order to provide the required power output, W/m, for the specified circuit length .
DimensionsType Nominal dimensions,
mmMinimum bending radius, mm
LLS 3×1 .5 14 .9×7 .8 40
LLS 3×3 .0 16 .9×8 .5 45
LLS 3×6 .0 19 .6×9 .4 50
ATTENTION!1. Do not let cables to be placed close to each other
and avoid cable self-overlapping to exclude overheating .
2 . Carefully follow the installation manual guidelines .
Power supply systemElectric heating system is powered either from a source (a specially designed step-up transformer where the availa-ble voltage is different from 380 V), or directly from 3-phase network via a power supply control system .
Allowable power of an electric supply network should be correspondent to the power consumed by the electrical heating system . Specially designed cold start scheme makes it possible to reduce the start currents .
Longline is a complete heating systemThe SSTenergomomtazh, LLC offers not just LLS heating cables, being a part of electric heating system, but de-signs, manufactures and installs complex systems, adapt-ed for specific conditions of application at the Customer’s site . In accordance with the Customer’s requirements the following items may be supplied: a power supply source (if the supply voltage is different from 380 VAC), system of power supply and temperature control, circuit continuity monitoring/alarming equipment, feed boxes, service boxes, termination kits – all above mentioned units are specially designed and manufactured by the manufactur-ing enterprise .
Application fieldLongline LLS is a three-phase constant wattage heating cable designed to prevent freezing or maintain the product temperature in pipelines of medium length up to 3 km in safe and explosion hazardous areas .
Its typical application is to maintain the temperature of product in above-ground and buried oil and gas lines and to prevent freezing of water lines .
HIGH-PERFORMANCE CONSTANT WATTAGE ELECTRICAL HEATING CABLE
34
Industrial heating
systems
Section lengthHeating section length depending on supply voltage, cross section of the electrical core and linear power output of the heating cable with organic-silicon rubber insulation .
Heating section length, m
Power output, W/m 50 40 30 20
Cross section, mm2 1,5 3,0 6,0 1,5 3,0 6,0 1,5 3,0 6,0 1,5 3,0 6,0
Linear voltage, V
220 250 320 — 280 370 — 335 470 — 425 600 —
380 440 560 870 485 650 970 580 770 1170 740 1020 1490
500 570 730 1150 640 850 1290 770 1020 1550 975 1350 1960
660 750 970 1520 845 1130 1700 1015 1350 2040 1280 1800 2590
Typical heating system arrangement
Power supply
Control cabinet
Air temperature sensor
Cable temperature sensor
Cable temperature sensor
Pipe temperature sensor
Pipe temperature sensor
Transformer Т1
Power supply cableFeed box
Service box
End box
End termination
Connection termination
Heating section
End termination
Heated pipeline
End termination
End termination
Heated pipe section boundary
Heated pipe section
boundary
35
Ind
ustr
ial h
eati
ng s
yste
ms
AccessoriesWe recommend using original accessories made by SSTenergomontazh Company to ensure trouble-free operation and meeting safety standards and require-ments .
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion TC RU C-RU .ГБ05В .0523 with explosion protection marking 1Ex e llС T1 . . .T6 Gb X
Certificate of conformity to the require-ments of Customs Union Technical Regula-tion TC RU C-RU .ГБ05В .0527 with explosion protection marking 1Ex e llС T2 . . .T3 Gb X
Certificate of Conformity to Technical Regulations on Fire Safety for electrical constant wattage heat-ing cables No . С-RU .ПБ37 .В .01429
Certificate of Conformity to Technical Regulations on Fire Safety for heating cable sections No . С-RU .ПБ37 .В .01462
36
Industrial heating
systems
SNFConstant wattage electrical heating cable for heating of pipelines, vessels and other process equipment in safe and hazardous areas
Linear power output up to 40* W/m
Full range of controls and accessories
Operating temperature up to 240 °С
Standard operating voltage 220 VAC and 380 VAC
1 2
3 4
1. Heating core
2. Fluoropolymer insulation
3. Nickel plated copper braid
4. Fluoropolymer outer jacket
FeaturesFluoropolymer insulated heating cable series is specially designed for application in areas requiring high operating temperature and high power output .
Fluoropolymer insulation allows using cable in wet and chemically active mediums .
The cable is supplied as ready-made heating sections with installation wires and couplings . The sections may be as well assembled of component parts delivered by the manufacturer on site according to design documents .
The on-site installation of the heating sections is quick and simple . Mounting tapes and other accessories are used to facilitate the installation process .
ConstructionHeating conductor
Cupronickel alloy, High resistance alloys
Conductor insulation Fluoropolymer
Braid Copper wire
Outer jacket Fluoropolymer
PurposeSNF heating cables are intended for heating of pipelines, vessels, process equipment and other objects in the temperature range from -60 to +240 °С .
Application fieldThe heating cables can be used in heating of equipment operating at high temperatures and high humidity level, in explosion hazardous areas and in areas, where corrosive chemical solutions or vapors may be present .
* Linear power output is determined during heating system design and depends on the temperature and structure of the object being heated .
ATTENTION!1. Do not let the cable loops approach or overlap each
other to avoid overheating of the cable .
2 . The installation manual should be strictly followed .
37
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data
Maximum operating temperature 240 °С
Maximum allowable temperature de-energized 260 °С
Maintain temperature up to 180 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Rated operating voltage 220 VAC and 380 VAC
Resistance of the protective braid, not more than 18 Ohm/km
Linear power output of a single cable up to 40 W/m
Minimum bending radius in storage and transportation 150 mm
Minimum permissible single bending radius during installation 30 mm
Heating cable parameters
CONSTANT WATTAGE ELECTRICAL HEATING CABLE WITH FLOURPOLYMERIC INSULATION AND OUTER JACKET
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion TC RU C-RU .ГБ05В .0523 with explosion protection marking 1Ex e llС T1 . . .T6 Gb X
Certificate of conformity to the require-ments of Customs Union Technical Regula-tion TC RU C-RU .ГБ05В .0527 with explosion protection marking 1Ex e llС T2 . . .T3 Gb X
Certificate of Conformity to Technical Regulations on Fire Safety for electrical constant wattage heat-ing cables No . С-RU .ПБ37 .В .01429
Certificate of Conformity to Technical Regulations on Fire Safety for heating cable sections No . С-RU .ПБ37 .В .01462 .
Heating cable type
Rated resistance at 20 °C
(Ohm/km)
Section length (star connection), U=380 V, (m)
Section length (hook joint), U = 220 V, (m)
Section length (line joint), U = 220 V, (m) Outer
diameter, (mm)Power output of single cable pass, W/m
10 20 30 15 25 35 20 30 40
SNF 01R8 1,81 1635 —* —* 1330 —* —* —* —* —* 7,20
SNF 02R9 2,95 1281 906 —* 1046 —* —* 906 —* —* 6,30SNF 04R4 4,42 1046 740 604 854 660 880 740 604 —* 5,61SNF 07R1 7,13 821 582 474 672 520 440 582 474 412 5,10SNF 09R7 9,65 707 501 408 578 448 378 501 408 354 4,75SNF 11R9 11,9 636 451 367 520 404 342 451 367 319 4,60SNF 17R4 17,4 527 373 304 432 334 282 373 304 264 4,30SNF 24R8 24,8 441 312 254 360 280 236 312 254 221 4,30SNF 32R7 32,7 383 272 221 314 244 206 272 221 192 4,60SNF 0050 50,0 309 219 178 252 196 166 219 178 155 4,32SNF 0062 62,0 278 197 161 228 176 150 197 161 139 4,28SNF 0080 80,0 247 175 143 202 156 132 175 143 124 4,02SNF 0100 100,0 218 155 126 178 138 116 155 126 109 4,32SNF 0142 142,0 184 131 106 150 116 98 131 106 92 4,20SNF 0178 178,0 165 117 95 134 104 88 117 95 83 3,96SNF 0200 200,0 154 109 89 126 98 82 109 89 77 4,15SNF 0250 250,0 138 98 80 114 88 74 98 80 69 4,00SNF 0340 340,0 119 84 69 98 76 64 84 69 60 3,88SNF 0410 410,0 108 77 63 88 68 58 77 63 54 4,28SNF 0490 490,0 99 70 57 82 62 54 70 57 50 4,05SNF 0590 590,0 91 64 52 74 58 48 64 52 45 3,96SNF 0665 665,0 85 60 49 70 54 46 60 49 43 3,90SNF 0765 765,0 79 56 46 64 50 42 56 46 40 3,84SNF 1000 1000,0 69 49 40 56 44 38 49 40 35 3,86SNF 1300 1300,0 61 43 35 50 38 33 43 35 30 3,75SNF 1480 1480,0 57 40 33 46 36 31 40 33 29 3,71SNF 1865 1865,0 51 36 29 42 32 28 36 29 25 3,96SNF 2825 2825,0 41 29 24 34 26 22 29 24 21 3,78SNF 3950 3950,0 35 25 20 28 22 18 25 20 18 3,66SNF 5900 5900,0 29 20 16 24 18 16 20 16 14 3,54SNF 7000 7000,0 26 19 15 22 16 14 19 15 13 3,50SNF 8000 8000,0 25 17 14 20 16 14 17 14 12 3,47
* – This cable is used as installation wire .
38
Industrial heating
systems
Connector SNF MFConnector for SNF heating cables
High mechanical strength and system structural reliability
Quick and easy installation
Chemical stability
Operating temperature up to 240 °С
Explosive safety
Supply voltage up to 380 V
1 2 3 4 5
1. Bushing
2. Sealing
3. Collet sleeve
4. Heat shrinkable tube
5. Body
FeaturesThe connector design ensures reliable operation of the heating section .
The connector body is made of strong thermoplastic material able to withstand temperature up to 240 °C .
Installation of the connector is quick and does not require special tools .
Heat shrinkable tubes secure electrical protection .
ConstructionBody high-temperature thermoplastic
Bushing high-temperature thermoplastic
Collet sleeve aluminum alloy
Sealing organosilicon rubber
Heat shrinkable tube fluoropolymer
Design options
SNF MF-03-01-1Connector intended to connect heating cables and installation wires less than 4 mm2 in cross sec-tion and to connect two cables .
SNF MF-05-00-1Connector intended to connect heating cables and installation wires over 4 mm2 up to 10 mm2 in cross section .
SNF MF-05-01-1Connector intended for connection of the heating cables 6 and 10 mm2 in cross section and for repair thereof .
ApplicationThe SNF MF Connector is intended to connect medium temperature heating cables SNF with the installation wires as well as to connect the heating cables to each other .
39
Ind
ustr
ial h
eati
ng s
yste
ms
Technical dataMaximum allowable temperature de-energized 240 °С
Ambient temperature range -60…+55 °С
Minimum installation temperature -60 °С
Maximum cross section of the Installation wire conductor up to 10 mm2
Rated operating voltage up to 380 V
Maximum current SNF MF-03-01-1 SNF MF-05-00-1 SNF MF-05-01-1
up to 50 А up to 90 А up to 100 А
Marking 1Ex e IIС Т2…Т3 Gb Х
Protection rating IP 66
Connector type vs types of SNF constant wattage electrical heating cables and SNF installation wires
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion TC RU C-RU .ГБ05В .0527 with explosion protection marking 1Ex e llС T2 . . .T3 Gb X
SNF Heating cable type
Installation wire type with linear power output of the heating cable making up
Connector type for joining of the heating cable and
installation wire
Connector type for joining of two heating cables
up to 20 W/m 20–30 W/m 30–40 W/mSNF 01R8 – – – – SNF MF-05-01-1SNF 02R9
SNF 01R8– – SNF MF-05-01-1
SNF 04R4
SNF 01R8
–
SNF MF-05-00-1
SNF MF-03-01-1
SNF 07R1
SNF 01R8SNF 09R7 SNF 02R9SNF 11R9SNF 17R4 SNF 04R4 SNF 02R9SNF 24R8 SNF 07R1 SNF 04R4
SNF 04R4
SNF MF-03-01-1
SNF 32R7 SNF 09R7SNF 0050
SNF 11R9
SNF 09R7SNF 0062
SNF 11R9
SNF 0080SNF 0100
SNF 07R1
SNF 0142SNF 0178SNF 0200SNF 0250SNF 0340SNF 0410
SNF 11R9
SNF 0490SNF 0590SNF 0665SNF 0765SNF 1000SNF 1300SNF 1480SNF 1865SNF 2825SNF 3950SNF 5900SNF 7000SNF 8000
* – This cable is used as installation wire .
CONNECTOR FOR MEDIUM-TEMPERATURE HEATING CABLES OF SNF TYPE
Ordering informationExample: Connector SNF MF-03-01-1
Connector type: 03 – for connection of cables with cross section less than 4 mm2; 05 – for connection of cables with cross section over 4 mm2. Application field: 00 – only for connection of the heating cable and SNF installation wire; 01 – for connection of both heating cable and installation wire and of
two SNF heating cables.Design version: 0 – without fluoropolymer heat shrinkable tubes; 1 – with fluoropolymer heat shrinkable tubes.
40
Industrial heating
systems
Flush-joint heating section based on TMF cableCable heating section for heating of pipelines, vessels and other process equipment
Linear power output up to 40* W/m
Flush-joint section construction – cost-effective solution
Operating temperature up to 180 °С
Easy installation
1. Insulation of fluoropolymer
2. Tinned copper braid
3. Outer jacket of fluoropolymer
4. Installation wire
5. Heating cable
6. Splice point mark
7. Point of conductors welding
8. Current-carrying conductor
9. Heating conductor
Features and application fieldFlush-joint heating sections are supplied to the site object as finished products ready for immediate use in accordance with the project . Absence of explicit coupling at the junction of the heating and current-carrying conductors is a distinguishing feature of this type of section . Insulation, braid and outer jacket of the section have undisturbed solid and uniform construction thus ensuring high reliability of the heating section .
Insulation and outer jacket are manufactured of fluoro-polymers, thus enabling the section to withstand high operating temperature (up to 180 °C) and resist exposure to chemically aggressive environment and oil products .
Standard sections have linear output of 40 and 30 W/m . Sections with other linear output value are manufactured on request or in accordance with the project .
Complete readiness of the section for installation and uni-formity of the external dimensions essentially facilitate the installation process .
Medium temperature flush-joint heating sections are the best solution for heating of pipelines, tanks and process equipment containing fuel oil, bitumen, paraffin and other high-viscous substance as well as for heating of pump station floors .
Construction
Heating conductor cupronickel alloys, resistance alloys
Conductor of the installation wire tinned copper wires
Conductor insulation fluoropolymer
Braid tinned copper wires
Outer jacket fluoropolymer
PurposeMedium temperature flush-joint heating sections based on TMF cable are designed for heating of pipelines, tanks, process equipment and other objects in the temperature range from -60 °C to +180 °C, including application in explosion hazardous areas, for protection against icing and snow deposition on industrial open areas .
1
2
3
4
4
4
5
5
6
6
7
8 9
* Linear power output is defined during heating system development work and depends on the temperature and construction of the object being heated .
41
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data
Maximum operating temperature 180 °С
Maximum permissible temperature (de-energized) 200 °С
Ambient temperature range -60…+50 °С
Minimum installation temperature -60 °С
Designed for operating voltage 220 and 380 VAC
Resistance of the protective braiding not more than 18 Ohm/km
Linear power output of a single cable up to 40* W/m
Minimum bending radius during storage and transportation 150 mm
Minimum permissible single bending radius at installation 30 mm
Parameters of stock-produced heating sections
Approval detailsCertificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 for TMOE heating sections with
explosion protection marking 1Ex e llС T1 . . .T6 Gb X . No . TC RU C-RU .ГБ05В .00523
Certificate of Conformity to Technical Regulations on Fire Safety for heating cable sections No . С-RU .ПБ37 .В .01462
TMOE CABLE HEATING SECTION
Ordering informationExample: Heating cable section
30TMOE2 (ТMF (7х0,3)н)-0270-040Linear power output of the heating part of the section, W/m Resistive section (of TM type) Single-conductor sectionPresence of the screenSupply voltage: 2 – 220–240 V,
3 – 380–400 VType of the heating cableLength of the heating part of the section, dmLength of the installation wire at both sides, dm
ATTENTION!1. Do not let the cable loops approach or overlap each
other to avoid overheating of the cable .2 . The installation manual should be strictly followed .3 . The point of the connection between the heating
cable and the installation wire is marked by foiled tape .
Section ref . type Section resistanceat 20°С, (Ohm)±%
Length of the heating part of the section (m)
Sectionpower output
(W)
Outerdiameter
(mm)
1 . Standard sections designed for operating voltage 220 V, linear power output 30 W/m**
30TMOE2 (TMF (7×0,3)н)-0270-040 55,89-64,92 27 810 4,10
30TMOE2 (TMF (7×0,3)сн)-0330-040 45,21-52,48 33 990 4,10
30TMOE2 (TMF (7×0,3)к)-0420-040 37,38-43,43 42 1260 4,10
30TMOE2 (TMF (7×0,3)а)-0490-040 30,87-35,96 49 1470 4,10
30TMOE2 (TMF (7×0,4)к)-0560-040 28,20-32,65 56 1680 4,46
30TMOE2 (TMF (7×0,4)а)-0650-040 23,24-26,91 65 1950 4,46
30TMOE2 (TMF (7×0,3)CuNi10)-0720-040 20,16-23,99 72 2160 4,10
30TMOE2 (TMF (7×0,4)CuNi10)-0960-040 15,36-17,95 96 2880 4,46
30TMOE2 (TMF (7×0,5)CuNi10)-1200-040 12,00-14,41 120 3600 4,76
30TMOE2 (TMF (7×0,5)CuNi6)-1480-040 8,88-11,84 148 4440 4,76
2 . Standard sections designed for operating voltage 220 V, linear power output 40 W/m**
40TMOE2 (TMF (7×0,3)н)-0240-040 49,68-57,70 24 960 4,10
40TMOE2 (TMF (7×0,3)сн)-0290-040 39,73-46,12 29 1160 4,10
40TMOE2 (TMF (7×0,3)к)-0360-040 32,04-37,22 36 1440 4,10
40TMOE2 (TMF (7×0,3)а)-0420-040 26,46-30,82 42 1680 4,10
40TMOE2 (TMF (7×0,4)к)-0480-040 24,17-27,98 48 1920 4,46
40TMOE2 (TMF (7×0,4)а)-0560-040 20,02-23,18 56 2240 4,46
40TMOE2 (TMF (7×0,3)CuNi10)-0630-040 17,64-20,99 63 2520 4,10
40TMOE2 (TMF (7×0,4)CuNi10)-0840-040 13,44-15,71 84 3360 4,46
40TMOE2 (TMF (7×0,5)CuNi10)-1050-040 10,50-12,61 105 4200 4,76
40TMOE2 (TMF (7×0,5)CuNi6)-1280-040 7,68-10,24 128 5120 4,76
** Two types of the heating sections TMOE are presented in the product range: with linear power output 30 W/m and 40 W/m with installation wire 4 m long at both sides . Manufacture of the sections with other power output values and other installation wire lengths is possible on request and according to the project .
42
Industrial heating
systems
MICHigh temperature mineral insulated heating cable with metal casing for heating of pipelines, vessels and process equipment
High mechanical strength High chemical stability Easy installation Supplied as ready-made sections Supply voltage up to 660 V Thermal stability up to +600 °С Explosion and fire safety
12
3
45
6
7
8
9
10
1. Heating conductor2. Conductor insulation – MgO (magnesium oxide)3. Metal outer jacket of the heating cable4. Hard soldering5. Electrical conductor6. Connection coupling7. Metal outer jacket of the installation wire8. Cable entry M209. Earthing10. Flexible installation wire
FeaturesHeating cable MIC is specially designed to be an effective and reliable tool where high operating temperature to be maintained, if heat liberation is high (for example, for heating of bitumen facilities and pipelines) .
Due to high thermal stability of the magnesium oxide in-sulation, MIC cable can be used where outer jacket tem-perature reaches 600 °C .
MIC cable has an excellent mechanical strength and high corrosion stability, it is fire-resistant and safe in operation and can be used in corrosive environments and explosion hazardous areas .
Purpose and application fieldHeating cable MIC is designed for heating of pipelines, vessels and process equipment in the temperature range from -50 to +600 °С in safe and explosion hazardous areas as well as in corrosive environment .
Heating cable MIC can be used in oil processing, chemical, pharmaceutical and food industries and many others .
Correct calculation of the electrical heating system power output makes it possible to use the cable in a wide temperature range .
The cable is supplied as ready-made sections . The section consists of the heating cable, connection couplings, installation wires, cable entries and flexible installation wires .
ATTENTION!1. Do not let the cable loops overlap each other to
avoid overheating of the cable .2 . The installation manual should be strictly followed .
Resistance to corrosive environments
– check is required
– not recommended
Outer jacket material Sulfur compounds
(H2S, SO
2)
Sulfuric acid*
Hydro-chlo-ric acid
Hydrofluoric acid Alkalis Phosphoric
acidSea
waterNitric acid Chlorine** Organic
acids ***
dry wet dry dry wet
Copper
Cupronickel alloy
Stainless steel *
Inconel
– recommended
– admissible
* – depending on concentration and temperature ** – resistance to chlorines depends on chemical composition of the salt *** – resistance to different organic acids differs
43
Ind
ustr
ial h
eati
ng s
yste
ms
Casing (outer jacket) versions
1. Copper Maximum heat stability up to 200 °С
2. Cupronickel alloy Maximum heat stability up to 400 °С
3. Inconel or stainless steel
Maximum heat stability up to 600 °С
Technical data
Operating voltage up to 660 V
Insulation resistance, not less than 103 MOhm•m
Maximum heat resistance up to 600 °С
Maximum maintenance temperature up tp 450 °С
Ambient temperature range -60…+50 °С
Temperature classification Т1
Earth leakage current 3 mA / 100 m
Minimum installation temperature –60 °С
Minimum bending radius 6 outer diameters
Cable design versions
CONSTANT WATTAGE ELECTRICAL HEATING CABLE WITH MINERAL INSULATION
Cable Conductor material
Conductor resis-tance at 20 °C,
Ohm/km
Cable outer diameter,
mm
Cold leads
Cross sec-tion, mm2
Diameter, mm
Heating cable in copper outer jacket
MIC Cu 4 Copper 4 5,9 16 8,3MIC Cu 7 Copper 7 5,3 10 7,3MIC Cu 11 Copper 11 4,9 6,0 6,4MIC Cu 17 Copper 17 4,6 6,0 6,4MIC Cu 25 Copper 25 3,7 6,0 6,4MIC Cu 40 Copper 40 3,4 2,5 5,3MIC Cu 63 Copper 63 3,2 2,5 5,3
Heating cable in cupronickel outer jacket
MIC CuNi 4 Copper 4 5,9 16 8,3MIC CuNi 7 Copper 7 5,3 10 7,3MIC CuNi 11 Copper 11 4,9 6,0 6,4MIC CuNi 17 Copper 17 4,6 6,0 6,4MIC CuNi 25 Copper 25 3,7 6,0 6,4MIC CuNi 40 Copper 40 3,4 2,5 5,3MIC CuNi 63 Copper 63 3,2 2,5 5,3MIC CuNi 160 Constantan 160 4,9 6,0 6,4MIC CuNi 250 Constantan 250 4,4 2,5 5,3MIC CuNi 400 Constantan 400 4,0 2,5 5,3MIC CuNi 630 Constantan 630 3,7 2,5 5,3MIC CuNi 1000 Constantan 1000 3,4 2,5 5,3MIC CuNi 1600 Constantan 1600 3,2 2,5 5,3
Heating cable in incolel, stainless steel outer jacket
MIC ** 160 Nichrome 160 6,5 6,0 6,4MIC ** 250 Nichrome 250 5,3 6,0 6,4MIC ** 400 Nichrome 400 4,7 2,5 5,3MIC ** 630 Nichrome 630 4,3 2,5 5,3MIC ** 1000 Nichrome 1000 3,9 2,5 5,3MIC ** 1600 Nichrome 1600 3,6 2,5 5,3MIC ** 2500 Nichrome 2500 3,4 2,5 5,3MIC ** 4000 Nichrome 4000 3,2 2,5 5,3MIC ** 6300 Nichrome 6300 3,2 2,5 5,3MIC ** 10K Nichrome 10000 3,2 2,5 5,3
** IL – Inconel, ST – Stainless steel
Maximum operating temperatures
Specific power output of heating, W/m
Figures on curves represent the maintained temperature values
Tem
pera
ture
of t
he h
eatin
g ca
ble
oute
r jac
ket,
°C
Specific power output of heating, W/m
Figures on curves represent the maintained temperature values
Tem
pera
ture
of t
he h
eatin
g ca
ble
oute
r jac
ket,
°C
Specific power output of heating, W/m
Do not use heating cables of MIC**6300 and MIC**10K type in conditions beyond those marked by dash-lines
Figures on curves represent the maintained temperature values
Tem
pera
ture
of t
he h
eatin
g ca
ble
oute
r jac
ket,
°C
Ordering informationExample: Heating cable section
35ТООE2(МIС CuNi 250)-0250-040
Linear power output, W/m Section name Supply voltage: (2 – 220, 3 – 380, 5 – 500, 6 – 660 V)Cable typeOuter jacket type (Сu – copper, CuNi – cupronickel alloy, IL – inconel, ST – stainless steel)Resistance, Ohm/kmLength of the heating part of the section, dmLength of the installation wire at each side (any length is possible on request), dmApproval details
Certificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 for TMOE heating sections with
explosion protection marking 1Ex e llС T1 . . .T6 Gb X . No . TC RU C-RU .ГБ05В .00523
Certificate of Conformity to Technical Regulations on Fire Safety for heating cable sections No . С-RU .ПБ37 .В .01462
44
Industrial heating
systems
SKIN-SYSTEMSafe and reliable heating system for pipelines of any length designed for above-ground, buried and under-water pipelining in safe and explosion hazardous areas .
Heating of pipelines of an unlimited length
No accompanying supply network required
High operating temperatures
Electrical safety
High mechanical strength of the heating system
Application in explosion hazardous areas
1. High-voltage power line
2. Packaged transformer substation (PTS)
3. Induction-resistive heater (IR-heater)
4. Induction-resistive conductor (IR-conductor)
5. Heat insulation
6. Pipeline being heated
5
6
3
4
Field of applicationInduction-resistive heating system (IRHS) or SKIN-system is designed to maintain the product temperature, protect long trunk pipelines against freezing and ensure their start heating .
SKIN-system is the only one, which is capable to heat a pipeline run of up to 30 km long (without any accompa-nying network) . This system can be also used for heating trunk pipelines of an unlimited length provided accom-panying supply network be arranged .
Principle of operationThe heating element of the system consists of an induction-resistive heater (IR-heater) with the outer diameter of 20–45 mm and the wall thickness of at least 3 .0 mm; there is an insulated copper or aluminum induction-resistive conductor (IR-conductor) with cross section of 10–30 mm2 placed in it .
The IR-conductor is electrically connected to the IR-heater at the end of a heating run while AC voltage is supplied between the conductor and the IR-heater at the run head; the voltage value is calculated basing on the required heat output and the heated run length .
Currents of the IR-conductor and the IR-heater have opposite directions and thus skin and proximity effects originate in the system . As a result, the IR-heater current flows in the inner layer close to the inner surface of the IR-heater and there is no voltage available on the outer surface of the IR-heater .
The IR-conductor is non-magnetic (made of copper, aluminum), thus, it does not feature any noticeable skin effect and AC flows throughout the whole cross section of the IR-conductor .
The main heat-producing element of IRHS is the tube, which produces up to 80 % of the system output .
1
2
Construction and system component parts
IR-heaterLow carbon steel tube with diameter of 20–45 mm and wall thickness of 3–4 mm
IR-conductor
Special conductor resistive to high voltage (up to 4 kV), high temperature (up to 200 °C) and mechanical stress at installation
IRFB, IRCB, IREB, IRC, PTS
Feed boxes, connection boxes, end boxes, connectors, Pack-aged Transformer Substation
45
Ind
ustr
ial h
eati
ng s
yste
ms
ELECTRICAL HEATING SYSTEM IRHS-15000
Technical data
Length of the heated pipelineUp to 30 km without accompanying sup-ply network
Power output of the heating system up to 120 W/m
Operating temperature 200 °С
Ambient temperature range -50…+50 °С
Heating element voltage up to 4 kV
Cross section of IR-conductor of the heater up to 30 mm2
Approval detailsCertificate of conformity to the requirements of Customs Union Technical Regulation No . 012/2011 «On safety of equipment in-
tended for use in explosive atmospheres» for the electrical heating system IRHS-15000 with explo-sion protection marking No . RU C-RU .ГБ05В .00378 .
Certificate of Conformity to Technical Regulations on Fire Safety for IRC conductors No . С-RU .ПБ37 .В .01459 .
Certificate of conformity IEC Ex No . IECEx CCVE 11 .0001X .
Permission of the Federal Service for Environmen-tal, Technological and Nuclear Supervision No . РРС 00-31340 for application of electrical heat-ing system IRHS-15000 of explosion-proof design .
Control and power supply scheme
Air temperature sensor
PACKAGED TRANSFORMER SUBSTATION
Control cabinet
Power cabinet
Pipeline temperature sensor
IR-heater temperature sensor
Special purpose transformer
Load balancing device
Power supply line
Transformer-capacitance converters are used to supply power to load, they consist of special purpose transformer and load balancing device . This device allows connecting high power single-phase load (the heater of the SKIN-system) to three-phase power supply network with no current imbalance in power supply network at that .
The control system monitors the ambient air temperature, IR-heater temperature, temperature of the pipeline being heated, load current and load voltage . The control system allows remote control over the heating process and supervision of all necessary parameters .
46
Industrial heating
systems
Heat emissionSpecific heat emission of one element, W/m
Maximum length of the heated pipeline, km
Heater diameter
42×332×325×3
Cross section of cur-rent-carrying conductor
40 mm2
20 mm2
10 mm2
IR-heater
IR-conductor
Heat conductive paste Silarm
Heat flow
Safety of the system is ensured by skin effect due to which the current flows in the inner layer of the IR-heater close to its inner surface with the voltage potential of the outer surface being equal to zero at that .
Heat transfer off SKIN-system to the pipeline is provided by a good contact and application of special heat con-ductive paste Silarm .
47
Ind
ustr
ial h
eati
ng s
yste
ms
48
Industrial heating
systems
CIDIREH – Heating system for wellsDevice for heating a well with a heating cable directly in tubing of petroleum fluid pumping
Prevention of paraffin crystallization
A heater with the output power varying along its length
Extended service time of heater due to its unique design
Energy saving by more than 20%
Energy efficiency
Environmental compatibility
Performance capabilities of the CIDIREH1. Automatic maintenance of the set temperature of
borehole fluid
2. Monitoring of current heating parameters
3. Automatic control of heating switching ON and OFF
4. Control and display of operations on LCD monitor of the operator’s panel
5. Automatic heating switching OFF when the tempera-ture exceeds the set level
6. Automatic restoring of the system operation .
Field of applicationThe device is intended for heating a well with a heating cable directly in tubing of petroleum fluid pumping . Heating is effected up to the temperature that exceeds the paraffin crystallization temperature .
The specific feature of this device is that there is used a cable with variable power output along its length .
Heater operation conditions In vertical position with attachment at the mouth
In stress and strained condition being subject to gravity
In oil and gas environment
In explosion hazard zones of category II С according to GOST 30852 .9-2002
With an ambient pressure of up to 150 atm .
At an oil temperature at depth of up to 50 °С with required heating power of 30…60 W/m
At a depth below the well ARPD crystallization point
Tensile load during operations of descent and lift from well is not less than the assembly tripled weight .
1. Automation cabinet
2. Feed box
3. Heater
1
2
3
49
Ind
ustr
ial h
eati
ng s
yste
ms
COMPLETE INDUSTRIAL DEVICE OF INDUCTION-RESISTIVE ELECTRICAL HEATING (CIDIREH)
Energy efficiency
1. Oil temperature by the well depth below which the paraffin crystallization appears .
2. Geothermic curve .
3. Oil temperature without the well heating .
4. Heater length .
5. Paraffin precipitation depth without heating .
6. Oil temperature when a heater with constant power output along the length is used .
7. Oil temperature when two-step heater is used .
8. Area of the two-step heater efficiency .
All known trace heaters have constant power output along their length (see Figure pos . 6) .
The design and the manufacturing technology offered by the SST, LLC enable to increase or to decrease the linear heat output in individual segments of the heater (see Fig-ure pos . 7) .
The length and the number of the fragments with various heat output is calculated based on the input data for each well individually .
Temperature, °C
Dep
th, m
50
Industrial heating
systems
1
34
2
InWarm Reform Industrial
InWarm Reform IndustrialInWarm Reform Industrial is an energy saving industrial coating that exhibits thermal-reflecting properties, prevents condensation of moisture and provides corrosive protection .
Excludes condensate phenomena
Blocks corrosion development under thermal insulation
Reduces destructive thermal shocks (cyclic, rapid change) on thermal insulation materials
Principle of applicationThe thermal shielding membrane InWarm Reform Indus-trial reflects solar radiation, reduces density of heat flow, differentiates warmth and cold due to the unique struc-ture that contains in a dry layer rarefied air encapsulated in ceramic microspheres in amount of 83–85 % of the to-tal volume of the membrane .
Eliminates effect of the solar radiation due to the high reflection capabilities
Lowers the temperature of hot surfaces
Protects personnel against thermal injury
The thermal shielding membranes InWarm Reform Industrial are manufactured on the basis of acryl-silicone dispersion and ceramic microsphere . The paste of low density is applied by spraying
Objects of application1. Tanks, storage vessels, reservoirs
2. Pipelines of various purpose
3. Power equipment
4. Technical areas of various purpose
51
Ind
ustr
ial h
eati
ng s
yste
ms
THERMAL SHIELDING MEMBRANES INWARM REFORM INDUSTRIAL
Technical dataTemperature range of operation from -40 to +170 °C
Temperature range of application from +5 до + 160 °C
Thermal conductivity by GOST 7076 0,068 W/m²/K
Fraction of insulating particles 83 %
Drying time between coats 2 hours at least
Consumption at 0,5 mm layer thickness 0,7 l/m²
Flammability G1
Service life 10 years at least
Container plastic can, 20 l in volume
Condensation prevention
Corrosion prevention under the thermal insulation
Reduction of temperature of hot equipment surfaces
Reflection of solar radiation, prevention of oil products evaporation
52
Industrial heating
systems
SILARMA Paste for improvement of heat contact between heating elements and objects to be heated
Decreases transition thermal resistance by several times
Reduces heat loss at active heating
Operating temperature range from -60 °C to+200 °C (SILARM-81) or + 180 °C (SILARM-3)
Protects steel surfaces against corrosion
Equalizes thermal field of the heating object
Available in 600 ml foil tubes or up to 5 liter cans
1. Heating cable
2. SILARM paste
3. Surface to be heated
Product modifications availableSILARM is available in two modifications – vulcanizing and non-vulcanizing .
SILARM-3 is non-vulcanizing single-component paste of white color with high viscosity, so that it does not stream down from vertical surfaces . It accurately fills any cavities and gaps .
SILARM-81 is vulcanizing two-component paste of white color with vulcanization period from 4 to 24 hours and high heat stability . In vulcanized condition, SILARM-81 features high dielectric properties .
Any additional sheath is not needed after the paste is ap-plied, for keeping shape and physical properties of ther-mal bridge created .
Thermal insulating materials can be laid immediately above the paste layer .
Temperature distribution
1
1 2
3
3
PurposeHeat conductive paste SILARM is designed for ensuring effective heat transfer from heating elements to the object to be heated in such applications as heating of pipelines, vessels and other constructions operating in temperature range from -60 °С to +200 °С (SILARM-81) or from -60 °С to 180 °С (SILARM-3) .
Principle of operationThe SILARM paste has high thermal conductivity . Being laid on contact area it fills gaps between the heater and the heated surface that improves sufficiently heat ex-change in the system . Using the paste prevents overheat-ing of the heating element .
Resistance to jumps in temperatureSILARM is resistant to low ambient temperatures up to -60 °C and to high temperatures up to +200 °C /180 °C and also to temperature jumps in this range . That ensures stable operation of heating system at temperature cy-cling .
Easy to useSILARM-3 is available in foil tubes 600 ml in volume . The paste is extruded from the tube to the surface to be heated by means of special pistol .
SILARM-81 is delivered as a set: the component No .1 (in cans up to 5 liters in volume) is completed with appropriate quantity of catalyst agent . After mixing of components, SILARM-81 is applied to a surface to be heated by spatula .
Safety and reliabilityAll components of the SILARM paste are safe and non-toxic, they do not send off substances hazardous to health . Routine production practice ensures sustained performance of the product .
Long service lifeTechnology level of the production and high quality components guarantee the life time of the paste not less than 10 years .
53
Ind
ustr
ial h
eati
ng s
yste
ms
HEAT CONDUCTIVE PASTE
Technical data Typical example of application
Modification SILARM-3 SILARM-81
Number of mixed components 1 2
Proportion of components — 1:100
Lifetime of components’ mixture, h — ≥1
Vulcanization time, h nonvulcanized 24
Heat resistance, °С 180 200
Cold-resistance, °С – 60 –60
Thermal conductivity, not less than, W/m°С 0,8 0,7
Density, not less than, g/cm3 2,5 2,3
Service life 10 years
AccessoriesThe manufacturer delivers everything required for using the paste SILARM: pistols, user’s manuals .
Approval detailsCertificate of Conformity for the Heat conductive paste SILARM-81 No . РОСС RU .АВ87 .Н03898
Certificate of Conformity for the Heat conductive paste SILARM-3 No . РОСС RU .АВ87 .Н03897
Technical specificationsSILARM-81: TU 2257-250-33006874-2004
SILARM-3: TU 2257-251-33006874-2004
SILARM is laid by means of pistol and filling knife (spatula) for improvement of heat contact between a tube to be heated and a tubular heater or heating cable .
54
Industrial heating
systems
* Simultaneous connection of three heating tapes of 33HTP or 60BTC type is not allowed .
РТВ 401Connection box for power supply connection to self-regulating electrical heating tapes
Efficient solution for power supply connection and input of self-regulating heating tapes through thermal insulation in electrical heating systems
May be used with self-regulating heating tapes of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 401 is a connection box purposed for connection of self-regulating electrical heating tapes to power network and for branching of the self-regulating heating tapes .
The box is fixed directly onto the pipeline .
The box enables connection of up to two self-regulating tapes* to power cable and connection of up to three tapes* for branching .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
1. Power cable
2. РТВ 401 connection box
3. Heating section (tape)
12
3
55
Ind
ustr
ial h
eati
ng s
yste
ms
CONNECTION BOXES
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69 UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/EX 3 modules 10 mm2
Terminal block WPE/EX 2 modules 10 mm2
Enclosure dimensions 122×120×90
Total weight (maximum) 1,55 kg
РТВ 401 box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass М25
Earthing tag, brass M25
Sealing ring M25
Cable gland GP25
Short-circuiter with fixtures П06 .06х150-00
Base section SEU .01 .01
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Sealing SEU .0013
Sealing SEU .0013-01
Blanking plug SEU .0014
Blanking plug SEU .0014-01
Screw М5х40
Washer 5
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 401 XS/0
Х – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)
* The component parts and their quantities are selected with order (see below)
Accessories(To be ordered separately):
Metal strap PFS/3 – for the box fixing onto a pipeline .
Heating tape termination kit – to be selected according to the used tape type .
Product rangeРТВ 401-1П/0РТВ 401-1Б/0
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
56
Industrial heating
systems
РТВ 401-ISConnection box with light indication
Provides light indication of power voltage existence at the end of the heating section
May be used with self-regulating heating tapes of all types
Approved by a certificate of conformity for use in explosion hazardous areas
Features high mechanical strength
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 401-IS is a version of PTВ 401 unit . It is purposed for indication of presence of power voltage across heating sections based on self-regulating heating tapes .
A lamp with extra bright LED signals the voltage presence at the end of a heating section .
The green LED with long lifetime is seen at any view angle including the case of direct sunlight incidence .
Design features:
– provides one heating tape entry
– ensures dust and moisture ingress protection rating IP66 as well as high corrosion resistance
– easy installation
1. РТВ 401-IS connection box
2. Heating section (tape)
1
2
57
Ind
ustr
ial h
eati
ng s
yste
ms
Дополнительные изделия(To be ordered separately):
Metal strap PFS/3 – for the box fixing onto a pipeline .
Technical data Delivery kitClimatic version and category of location according to GOST 15150-69 UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e d IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 230 V
Electric lamp lifetime >105 h
Lamp consuming power <1 W
Terminals up to 2,5 mm2
Light source green LED
Light coverage 180°
Enclosure dimensions 122×120×90
Total weight (maximum) 1,5 kg
РТВ 401-IS box enclosure
Sealing SEU .0013
Sealing SEU .0013-01
Blanking plug SEU .0014
Blanking plug SEU .0014-01
Base section SEU .0101
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Screw М5х40
Washer 5
Ordering informationExample: РТВ 401- IS
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e d llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
58
Industrial heating
systems
РТВ 402Connection box for power supply connection to self-regulating electrical heating tapes
Efficient solution for power supply connection of self-regulating heating tapes in electrical heating systems
May be used with self-regulating heating tapes of all types
Eliminates the risk of damage to heating tapes at termination point
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range Quick and easy installation High thermal stability Non-corrosive
DescriptionPTВ 402 is a connection box purposed for connection of self-regulating heating tapes to power network .
The box is fixed on a building wall, on neighboring metal construction or, by means of a bracket, directly onto the pipeline .
The box enables connection of one or two self-regulating tapes .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
2
3
4
5
1
1. Power cable
2. РТВ 402 connection box
3. Heating section (tape)
4. Protection hose
5. Cable entry unit
59
Ind
ustr
ial h
eati
ng s
yste
ms
Accessories(To be ordered separately):
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Bracket РВ – for the box fixing onto a pipeline .
Heating tape termination kit – to be selected according to the used tape type .
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/Ex 3 modules 10 mm2
Terminal block WPE/Ex 2 modules 10 mm2
Enclosure dimensions 122×120×90
Total weight (maximum) 1,55 kg
РТВ 402 box enclosure
Armored cable entry, brass М25 Ех
Unarmored cable entry, plastic М25 Ех
Locking nut, brass М25
Earthing tag, brass М25
Sealing ring М25
Cable gland GP25
Short-circuiter with fixtures П06 .06х150-00
Blanking plug M25 Ex
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 402 XS/YJ/ZPL
Х – number of «input» cable entriesS – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (П – plastic entry)Z – number of flexible entriesP – flexible entry L – type of entry (Ш – hose entry)
* The component parts and their quantities are selected with order (see below)) .
Product rangeРТВ 402-1П/1ПРТВ 402-1П/2ПРТВ 402-1Б/1ПРТВ 402-1Б/2ПРТВ 402-2Б/1П
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
60
Industrial heating
systems
РТВ 402-IS
Provides light indication of power voltage existence at the end of the heating section
May be used with self-regulating heating tapes of all types
Approved by a certificate of conformity for use in explosion hazardous areas
Features high mechanical strength
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 402-IS is a version of PTВ 402 unit . It is purposed for indication of presence of power voltage across heating sections based on self-regulating heating tapes .
A lamp with extra bright LED signals the voltage presence at the end of a heating section .
The green LED with long lifetime is seen at any view angle including the case of direct sunlight incidence .
Design features:
– provides one heating tape entry
– ensures dust and moisture ingress protection rating IP66 as well as high corrosion resistance
– easy installation
Connection box with light indication
1. РТВ 402-IS connection box
2. Protection hose
3. Heating section (tape)
2
3
1
61
Ind
ustr
ial h
eati
ng s
yste
ms
Accessories(To be ordered separately):
Bracket РВ – for the box fixing onto a pipeline .
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Technical data Delivery kitClimatic version and category of location according to GOST 15150-69 UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e d IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 230 V
Electric lamp lifetime >105 h
Lamp consuming powe <1 W
Terminals up to 2,5 mm2
Light source green LED
Light coverage 180°
Enclosure dimensions 122×120×90
Total weight (maximum) 1,2 kg
РТВ 402-IS box enclosure
Unarmored cable entry, plastic М25 Ex
Sealing ring М25
Cable gland GSL2S
Ordering informationExample: РТВ 402- IS
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
62
Industrial heating
systems
РТВ 403
Efficient solution for control cables connection and input through thermal insulation
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 403 is a connection box purposed for connection of heating system control cables .
The box enables connection of one or two control cables, up to 3 temperature sensors and input through thermal insulation of up to 4 temperature sensors (1 reserved) .
The enclosure design ensures moisture and dust ingress protection rating IP66 and high corrosion stability .
Cable entries of the box are designed for connection of unarmored power cables of 7 to 18 mm in diameter and armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 0,5 до 2,5 mm2 in cross section .
Connection box for control cables connection
1. Control cable
2. РТВ 403 connection box
3. Sensor’s installation wire
4. Temperature sensor
12
3
4
63
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate 1)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current 21 А
Terminal block WDU/Ex 9 modules 2,5 mm2
Enclosure dimensions 122×120×90
Total weight (maximum) 1,8 kg
РТВ 403 box enclosure
Armored cable entry, brass М25 Ex
Unarmored cable entry, plastic М25 Ex
Locking nut, brass М25
Earthing tag, brass М25
Sealing ring М25
Cable gland GP25
Blanking plug M25 Ex
Sealing SEU .0015
Blanking plug SEU .0016
Base section SEU .01 .01
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Screw М5×40
Washer 5
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for control cables connection .
Example: РТВ 403 XS/YJ
Х – number of «input» cable entriesS – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (Б – armored, П – plastic entry)
Accessories(To be ordered separately):
Metal strap PFS/3 – for the box fixing onto a pipeline .
Product rangeРТВ 403-1П/0
РТВ 403-2П/0
РТВ 403-1Б/0
РТВ 403-1Б/1Б
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
64
Industrial heating
systems
РТВ 404
Efficient solution for control cables connection and input through thermal insulation
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 404 is a connection box purposed for connection of heating system control cables .
The box enables connection of one or two control cables, up to 3 temperature sensors and output of one or two temperature sensors .
The enclosure design ensures moisture and dust ingress protection rating IP66 and high corrosion stability .
Cable entries of the box are designed for connection of unarmored power cables of 7 to 18 mm in diameter and armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 0,5 до 2,5 mm2 in cross section .
Connection box for control cables connection
1. Control cable
2. РТВ 404 connection box
3. Sensor’s installation wire
4. Temperature sensor
5. Protection hose
6. Cable entry unit
1
2
3
4
6
3
65
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate 1)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current 21 А
Terminal block WDU/Ex 9 modules 2,5 mm2
Enclosure dimensions 122×120×90
Total weight (maximum) 1,5 kg
РТВ 404 box enclosure
Armored cable entry, brass М25 Ex
Unarmored cable entry, plastic М25 Ex
Locking nut, brass М25
Earthing tag, brass М25
Blanking plug M25 Ex
Sealing ring М25
Cable gland GSL25
Cable gland GP25
* The component parts and their quantities are selected with order (see below)
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for control connection .
Example: РТВ 404 XS/YJ/ZPL
Х – number of «input» cable entriesS – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (Б – armored entry, П – plastic entry)Z – number of flexible entriesP – flexible entry L – type of entry (Ш – hose entry)
Accessories(To be ordered separately):
Bracket РВ – for the box fixing onto a pipeline .
Metal strap PFS/3 – for the box fixing onto a pipeline .
Product rangeРТВ 404-1Б/0РТВ 404-2Б/1ПРТВ 404-1Б/2ПРТВ 404-1П/0РТВ 404-1П/2П
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
66
Industrial heating
systems
РТВ 405
Efficient solution for power supply connection and input of SNF and TMF constant wattage heating cables
May be used with SNF and TMF cables of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 405 is a connection box purposed for connection of SNF and TMF constant wattage heating cables to power network .
The box is fixed directly onto the pipeline .
The box enables connection of one or two heating cable sections realizing loop connection pattern or three sections realizing star connection pattern .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
Connection box for power supply connection to constant wattage heating cables
1. Power cable
2. РТВ 405 connection box
3. Installation wire
4. SNF MF connection unit (for SNF cable)
5. Heating section
12
3
4
4
5
67
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/Ex 3 modules 10 mm2
Terminal block WРЕ/Ex 2 modules 10 mm2
Enclosure dimensions 122×120×90
Total weight (maximum) 1,54 kg
РТВ 405 box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M25 Ex
Earthing tag, brass M25 Ex
Sealing ring M25
Blanking plug M25 Ex
Cable gland GP25
Short-circuiter with fixtures П06 .06х150-00
Base section SEU .01 .01
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Sealing SEU .0015
Blanking plug SEU .0016
Screw М5х40
Washer 5
* The component parts and their quantities are selected with order (see below) . .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 405 XS/0
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)
Accessories(To be ordered separately):
Metal strap PFS/3 – for the box fixing onto a pipeline .
Product rangeРТВ 405-1П/0РТВ 405-1Б/0РТВ 405-0/0
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
68
Industrial heating
systems
РТВ 406
Efficient solution for power supply connection of mineral-insulated cable
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 406 is a connection box purposed for connection of constant wattage heating cables of MIC type to power network .
The box enables connection of one heating cable section .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
Connection box for power supply connection to heating sections based on mineral-insulated cables (MIC)
1. Power cable
2. РТВ 406 connection box
3. Heating section
4. Connection coupling
5. Bracket
1
2
34
5
69
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/Ex 2 modules 10 mm2
Terminal block WРЕ/Ex 2 modules 10 mm2
Enclosure dimensions 122×120×90
Total weight (maximum) 1,2 kg
РТВ 406 box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Earthing tag, brass M25 Ex
Locking nut, brass M25 Ex
Sealing ring M25
Sealing ring M20
Cable gland GP25
Blanking plug M20 Ex
Short-circuiter with fixtures П06 .06х150-00
* The component parts and their quantities are selected with order (see below)
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 406 XS/0
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)
Accessories(To be ordered separately):
Bracket ПЛ .PTB 0606 – for the box fixing onto a pipeline .
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Product rangeРТВ 406-1П/0РТВ 406-1Б/0
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
70
Industrial heating
systems
РТВ 601
Efficient solution for power supply connection and input of self-regulating heating tapes through thermal insulation in electrical heating systems
May be used with self-regulating heating tapes of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 601 is a connection box purposed for connection of self-regulating electrical heating tapes to power network .
The box is fixed directly onto the pipeline .
The box enables connection of up to four self-regulating tapes .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
Connection box for power supply connection to self-regulating electrical heating tapes
1. Power cable
2. РТВ 601 connection box
3. Heating section (tape)
4. Protection hose
5. Cable entry unit
1
2
3
4
5
71
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/Ex 5 modules 10 mm2
Terminal block WРЕ/Ex 2 modules 10 mm2
Enclosure dimensions 160×160×90
Total weight (maximum) 2,76 kg
РТВ 601 box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M25
Earthing tag, brass M25
Sealing ring M25
Short-circuiter with fixtures П06 .06х150-00
Base section SEU .01 .01
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Screw М5х40
Washer 5
Blanking plug M25 Ex
Sealing SEU .0013
Sealing SEU .0013-01
Blanking plug SEU .0014
Blanking plug SEU .0014-01
Cable gland GP25
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of num-ber and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 601 XS/YJ/ZPL
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (Б – armored entry, П – plastic entry)Z – number of flexible entriesР – flexible entry L – type of entry (Ш – hose entry)Accessories
(To be ordered separately):
Metal strap PFS/3 – for the box fixing onto a pipeline .
Heating tape termination kit – to be selected according to the used tape type .
Product rangeРТВ 601-1Б/0 РТВ 601-1Б/1Б РТВ 601-1Б/1ПРТВ 601-1Б/2Б РТВ 601-1Б/2П РТВ 601-1П/1ПРТВ 601-1П/2П РТВ 601-2Б/1П
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
72
Industrial heating
systems
РТВ 601-IS
Efficient solution for power supply connection, input of self-regulating heating tapes through thermal insulation in electrical heating systems and providing light indication of power voltage existence
May be used with self-regulating heating tapes of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 601-IS is a connection box purposed for connection of self-regulating heating tapes to power network and for light indication of presence of power voltage across heating sections .
The box is fixed directly onto the pipeline .
The box enables connection of up to four self-regulating electrical heating tapes .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
A lamp with extra bright LED signals the voltage presence in the power network .
The green LED with long lifetime is seen at any view angle including the case of direct sunlight incidence .
Connection box with light indication for power supply connection to self-regulating electrical heating tapes
1. Power cable
2. РТВ 601-IS connection box
3. Heating section (tape)
4. Protection hose
5. Cable entry unit
1
2
3
4
5
73
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69 UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e d llC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 230 V
Operating current up to 50 A
Terminal block WDU/Ex 4 modules 10 mm2
Terminal block WРЕ/Ex 2 modules 10 mm2
Electric lamp lifetime >105 h
Lamp consuming power <1 W
Terminals up to 2,5 mm2
Light source green LED
Enclosure dimensions 160×160×90
Light coverage 180°
Total weight (maximum) 2,44 kg
РТВ 601-IS box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M25
Earthing tag, brass M25
Sealing ring M25
Short-circuiter with fixtures П06 .06х150-00
Base section SEU .01 .01
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Screw М5х40
Washer 5
Blanking plug M25 Ex
Sealing SEU .0013
Sealing SEU .0013-01
Blanking plug SEU .0014
Blanking plug SEU .0014-01
Cable gland GP25
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of num-ber and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 601 XS/YJ- IS
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (Б – armored entry, П – plastic entry)IS – light indication
Accessories(To be ordered separately):
Metal strap PFS/3 – for the box fixing onto a pipeline .
Heating tape termination kit – to be selected according to the used tape type .
Product rangeРТВ 601-1П/0-IS РТВ 601-1Б/1Б-ISРТВ 601-1П/1П-IS РТВ 601-1Б/1П-ISРТВ 601-1П/2П-IS РТВ 601-1Б/2П-ISРТВ 601-1Б/0-IS РТВ 601-2Б/1П-IS
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
74
Industrial heating
systems
РТВ 602
Efficient solution for power supply connection self-regulating heating tapes in electrical heating systems
May be used with self-regulating heating tapes of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 602 is a connection box purposed for connection of self-regulating electrical heating tapes to power network and for branching of power cables . .
The box is fixed by means of a bracket on building wall, neighboring metal construction, or directly onto the pipeline .
The box enables connection of up to three self-regulating tapes .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unar-mored power cables of 7 to 18 mm in diameter or ar-mored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multi-core or single core conductors of 1,5 до 10 mm2 in cross section .
Connection box for power supply connection to self-regulating electrical heating tapes
1. Power cable
2. РТВ 602 connection box
3. Heating section (tape)
4. Protection hose
5. Cable entry unit
1
2
3
4
5
75
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/Ex 5 modules 10 mm2
Terminal block WPE/Ex 2 modules 10 mm2
Enclosure dimensions 160×160×90
Total weight (maximum) 2,5 kg
РТВ 602 box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M25
Earthing tag, brass M25
Blanking plug M25 Ex
Sealing ring M25 Ex
Short-circuiter with fixtures П06 .06х150-00
Cable gland GP25
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 602 XS/YJ/ZPL
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (Б – armored entry, П – plastic entry)Z – number of flexible entriesР – flexible entry L – type of entry (Ш – hose entry)Accessories
(To be ordered separately):
Bracket РВ – for the box fixing onto a pipeline .
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Heating tape termination kit – to be selected according to the used tape type .
Product rangeРТВ602-1П/1П РТВ602-1П/2П РТВ602-1П/3ПРТВ602-2П/3П РТВ602-1Б/1П РТВ602-1Б/2ПРТВ602-1Б/3П РТВ602-2Б/1П РТВ602-2Б/2ПРТВ602-2Б/3П
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
76
Industrial heating
systems
РТВ 602-IS
Efficient solution for power supply connection and providing light indication of power voltage existence across self-regulating heating tapes in electrical heating systems
May be used with self-regulating heating tapes of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 602-IS is a connection box purposed for connection of self-regulating heating tapes to power network, branching of power cables and for light indication of presence of power voltage across heating sections .
The box is fixed by means of a bracket on building wall, neighboring metal construction, or directly onto the pipeline .
The box enables connection of up to three self-regulating electrical heating tapes
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unar-mored power cables of 7 to 18 mm in diameter or ar-mored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multi-core or single core conductors of 1,5 до 10 mm2 in cross section .
A lamp with extra bright LED signals the voltage presence in the power network .
The green LED with long lifetime is seen at any view angle including the case of direct sunlight incidence .
Connection box with light indication for power supply connection to self-regulating electrical heating tapes
1. Power cable
2. РТВ 602-IS connection box
3. Heating section (tape)
4. Protection hose
5. Cable entry unit
1
2
3
4
5
77
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69 UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e d IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 230 V
Operating current up to 50 А
Terminal block WDU/Ex 4 modules 10 mm2
Terminal block WPE/Ex 2 modules 10 mm2
Electric lamp lifetime >105 h
Lamp consuming power <1 W
Terminals up to 2,5 mm2
Light source green LED
Enclosure dimensions 160×160×90
Total weight (maximum) 2,6 kg
Light coverage 180°
РТВ 602-IS box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M25
Earthing tag, brass M25
Blanking plug M25 Ex
Sealing ring М25 Ex
Short-circuiter with fixtures П06 .06×150-00
Cable gland GP25
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 602 XS/YJ- IS
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)Y – number of «output» cable entriesJ – type of cable entries (Б – armored entry, П – plastic entry)IS – light indication
Accessories(To be ordered separately):
Bracket РВ – for the box fixing onto a pipeline .
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Heating tape termination kit – to be selected according to the used tape type .
Product rangeРТВ 602-1П/3П-IS РТВ 602-2Б/1П-ISРТВ 602-1П/4П-IS РТВ 602-1Б/2П-ISРТВ 602-1Б/3П-IS РТВ 602-2Б/3П-ISРТВ 602-1Б/4П-IS
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
78
Industrial heating
systems
РТВ 605
Efficient solution for power supply connection and input of SNF and TMF constant wattage heating cables
May be used with SNF and TMF cables of all types
Eliminates the risk of damage to heating tapes at termination points
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 605 is a connection box purposed for connection of SNF and TMF constant wattage heating cables to power network .
The box enables connection of one or two heating cable sections realizing loop connection pattern or three sec-tions realizing star connection pattern .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unar-mored power cables of 14 to 25 mm in diameter or ar-mored power cables of 17 to 26,3 mm in diameter .
The installed terminal blocks ensure connection of multi-core or single core conductors of 1,5 до 16 mm2 in cross section .
Connection box for power supply connection to constant wattage heating cables
1. Power cable
2. РТВ 605 connection box
3. Installation wire
4. SNF MF connection unit (for SNF cable)
5. Heating section
1
2
3
5
4
4
79
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 750 V
Operating current up to 66 A
Terminal block WDU/Ex 3 modules 16mm2
Terminal block WРЕ/Ex 2 modules 16 mm2
Enclosure dimensions 160×160×90
Total weight (maximum) 2,3 kg
РТВ 605 box enclosure
Armored cable entry, brass M32 Ex
Unarmored cable entry, plastic M32 Ex
Locking nut, brass M32
Earthing tag, brass M32
Blanking plug M32 Ex
Sealing ring M32 Ex
Short-circuiter with fixtures П06 .06х150-00
Base section SEU .01 .01
Plate SEU .0012
Nut DESTU .002
Ring (with rectangular cross section)
Screw М5х40
Washer 5
Sealing SEU .0015
Blanking plug SEU .0016
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 605 XY/0
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)
Accessories(To be ordered separately):
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Product rangeРТВ 605-1П/0РТВ 605-1Б/0РТВ 605-0/0
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
80
Industrial heating
systems
РТВ 606
Efficient solution for power supply connection of mineral-insulated cables
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 606 is a connection box purposed for connection of constant wattage heating cables of MIC type to power network .
The box enables connection of two heating cable sections realizing loop connection pattern or three sections realizing star connection pattern .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
Cable entry of the box is designed for connection of unarmored power cables of 7 to 18 mm in diameter or armored power cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multicore or single core conductors of 1,5 до 10 mm2 in cross section .
Connection box for power supply connection to heating sections based on mineral-insulated cables (MIC)
1. Power cable
2. РТВ 606 connection box
3. Heating section
4. Connection coupling
5. Installation wire
6. Bracket
1
2
34
5
6
81
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 550 V
Operating current up to 50 A
Terminal block WDU/Ex 3 modules 10 mm2
Terminal block WРЕ/Ex 2 modules 10 mm2
Enclosure dimensions 160×160×90
Total weight (maximum) 1,76 kg
РТВ 606 box enclosure
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Earthing tag, brass M25 Ex
Locking nut, brass M25 Ex
Blanking plug M20 Ex
Sealing ring M25 Ex
Sealing ring M20 Ex
Short-circuiter with fixtures П06 .06х150-00
Cable gland GP25
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables and self-regulating tapes connection .
Example: РТВ 606 XS/0
X – number of «input» cable entries S – type of cable entries (Б – armored entry, П – plastic entry)
Accessories(To be ordered separately):
Bracket ПЛ .PTB 0606 – for the box fixing onto a pipeline .
Metal strap PFS/3 – for the bracket fixing onto a pipeline .
Product rangeРТВ 606-1П/0РТВ 606-1Б/0РТВ 606-0/0
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
82
Industrial heating
systems
РТВ 1005
Efficient solution for power supply cables connection in electrical heating systems
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 1005 is a connection box purposed for connection of power supply cables in electrical heating systems .
The box enables connection of up to six power cables .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
The box is equipped with the following cable entries:
– up to two entries for connection of unarmored cables of 14 to 25 mm in diameter or armored cables of 17 to 26,3 mm in diameter .
– up to four entries for connection of unarmored cables of 7 to 18 mm in diameter or armored cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multi-core or single core conductors of 2,5 до 35 mm2 in cross section .
Connection box for power supply cables connection in electrical heating systems
1. Power cable
2. РТВ 1005 connection box
3. Power cable
4. Connection box
12
3
4
83
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 750 V
Operating current up to 109 A
Terminal block WDU/Ex 8 modules 35 mm2
Terminal block WРЕ/Ex 4 modules 35 mm2
Enclosure dimensions 250×255×120
Total weight (maximum) 5,9 kg
РТВ 1005 box enclosure
Armored cable entry, brass M32 Ex
Unarmored cable entry, plastic M32 Ex
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M32
Locking nut, brass M25
Earthing tag, brass M32
Earthing tag, brass M25
Blanking plug M32 Ex
Blanking plug M25 Ex
Sealing ring M32 Ex
Sealing ring M25 Ex
Short-circuiter with fixtures П06 .06х150-00
Cable gland GP32
Cable gland GP25
* The component parts and their quantities are selected with order (see below)
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables con-nection .
Example: РТВ 1005–XS/YJ
X – number of input cable entries М32S – type of cable entries М32 (Б – armored entry М32, П – plastic entry М32)Y – number of output cable entries М25J – type of cable entries М25 (Б – armored entry М25 , П – plastic entry М25)
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
84
Industrial heating
systems
РТВ 1006
Efficient solution for power supply cables connection in electrical heating systems
Approved by a certificate of conformity for use in explosion hazardous areas
All required component parts are included in the delivery kit of the box
Wide application range
Quick and easy installation
High thermal stability
Non-corrosive
DescriptionPTВ 1006 is a connection box purposed for connection of power supply cables in electrical heating systems .
The box enables connection of up to six power cables .
The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability .
The box is equipped with the following cable entries:
– up to two entries for connection of unarmored cables of 23,5 to 33,6 mm in diameter and armored cables of 18 to 32 mm in diameter .
– up to four entries for connection of unarmored cables of 7 to 18 mm in diameter or armored cables of 12 to 20 mm in diameter .
The installed terminal blocks ensure connection of multi-core or single core conductors of 2,5 до 35 mm2 in cross section .
Connection box for power supply cables connection in electrical heating systems
1. Power cable
2. РТВ 1006 connection box
3. Power cable
4. Connection box
12
3
4
85
Ind
ustr
ial h
eati
ng s
yste
ms
Technical data Delivery kit*Climatic version and category of location according to GOST 15150-69
UHL1 (boreal climate)
Moisture and dust ingress protection rating IP66
Explosion protection marking 1Ex e IIC T3 . . .T6 Gb X
Temperature Group of explosion hazardous area Т6
Operating ambient temperature range -60 . . .+50 °С
Operating voltage up to 750 V
Operating current up to 109 A
Terminal block WDU/Ex 8 modules 35 mm2
Terminal block WРЕ/Ex 4 modules 35 mm2
Enclosure dimensions 250×255×120
Total weight (maximum) 6,5 kg
РТВ 1006 box enclosure
Armored cable entry, brass M40 Ex
Armored cable entry, brass M25 Ex
Unarmored cable entry, plastic M40 Ex
Unarmored cable entry, plastic M25 Ex
Locking nut, brass M40
Locking nut, brass M25
Earthing tag, brass M40
Earthing tag, brass M25
Blanking plug M40 Ex
Blanking plug M25 Ex
Sealing ring M40 Ex
Sealing ring M25 Ex
Short-circuiter with fixtures П06 .06х150-00
Cable gland GP40
Cable gland GP25
* The component parts and their quantities are selected with order (see below) .
Ordering informationРТВ connection boxes are marked with indication of number and type of cable entries for power cables con-nection .
Example: РТВ 1006–XS/YJ
X – number of input cable entries M40S – type of cable entries M40 (Б – armored entry M40,
П – plastic entry M40)Y – number of output cable entries M25J – type of cable entries M25 (Б – armored entry M25,
П – plastic entry M25)
Approval detailsCertificate of conformity to the require-ments of Customs Union Technical Regula-tion No . 012/2011 «On safety of equipment
intended for use in explosive atmospheres» with explosion protection marking 1Ex e llС T3 . . .T6 Gb X TC RU C-RU .ГБ05В .00522
CONNECTION BOXES
86
Industrial heating
systems
Effective means of distribution cabinet heating
Protection against low temperatures
Condensation preventing
Increase of service life of the electric equipment installed
High reliability
Control over heating power output depending on environmental sensor readings
Designed for DIN rail mounting
Application The control cabinet heater is designed for anti-condensa-tion heating and maintenance of positive temperature in the cabinet .
FeaturesThe heater is specially developed to improve the reliability of control equipment operation in cold season thus extending the life span of the said equipment .
The heating element is made of special heat-conductive material, what ensures high heat transfer, decreases the weight considerably, and improves electrical strength and hermeticity of the heater .
The heat emitted distributes evenly over large surface through finned metal body of the heater .
The materials used ensure high stability of the heater to both subzero and high positive temperatures .
The installation of the heater is simple and quick . The fastenings allow quick heater installation in the control cabinet .
Control cabinet heater designed to protect control equipment against low temperatures
1. Aluminium radiant element
2. Heating element
3. Crossbar
4. Screw
5. DIN rail fastener
6. Installation wire
7. Thermal switch
8. Bimetallic thermostat
1
2
7 8
35
6
4
Reliability and electrical safetyThe heating element is protected by metal outer jacket from both sides . This insures mechanical protection against damages .
Supply lead is made of silicon wire resistive to overheating .
Reliable operation of the heater is ensured by high electri-cal strength and insulation resistance of the dielectric materials used .
All items undergo factory tests .
It is recommended to use the heating system completed with temperature controller PT-420 to control the tem-perature inside the cabinet .
As a result, the maximum power output is used at low temperatures, and it is decreased in step with temperature rise .
NSHU
87
Ind
ustr
ial h
eati
ng s
yste
ms
CONTROL CABINET HEATER
Technical data Installation details
Ordering informationExample: Control cabinet heater
NSHU-150A
Control cabinet heaterRated power consumption, W
Heater installation options:
а) without heat-reflective screen,б) with the use of heat-reflective screen
100
mm
equipment equipment
20 m
m20
mm
2 m
m
NSHU
NSHU
а) б)
Correct position of the DIN-rail fastener
top
bottom
Parameter
NSHU-150А NSHU-200А NSHU-300А
Dimensions, mm 240×170×50 180×125×80 240×170×80
Rated AC 50 Hz supply voltage, V 220 ± 10%
Rater power*, W 150 200 300
Maximum permissible temperature of the heater’s surface, °C
125
Maximum permissible air temperature at the heater’s operation, °C
+20
Minimum permissible air temperature at the heater’s operation, °C
-50
Installation wire length, m not least than 1,5
Class of protection against electric-shock hazard according to GOST R 52161 .1-2004
I
Ingress protection rating according to GOST 14254-96 IP44
Weight, kg 2,00 1,85 3,40
* The tolerance range of the rated power is plus 5 %, minus 10 % . The rated power is defined at ambient temperature plus 25°С .
Delivery kitThe delivery kit includes:
NSHU-150A NSHU-200A NSHU-300A
Technical Certificate with Operation Manual 1 1 1
Heater 1 1 1
Individual packing 1 1 1
Crossbar with DIN-rail fastener 1 1 1
Screw M3 4 8 8
Washer GOST 6402-70 4 8 8
Washer GOST 10450-78 4 8 8
Approval detailsCertificate of conformity for the NSHU heater РОСС RU .AB87 .B01815
АВ87
88
Industrial heating
systems
TERMINATION KIT FOR ELECTRICAL HEATING TAPES TKL, TKR
Accessories for the TEPLOMAG system installation
DescriptionStandard termination kits for self-regulating electrical heating tapes contain boots made of organic-silicon rub-ber making possible simple and quick termination of tapes’ ends .
The kit includes crimp-type tips, tube for earthing wire, organic-silicon sealing for cable entry M25, adhesive seal-ant 10 ml and heat shrinkable tube intended to enforce the mechanical properties of the end termination ensur-ing its additional strength .
Termination kit vs. heating tape type
Ref . type of the kit
Maximum expo-sure tempera-ture, °C
Ref . type of self-regulating heating tape
ТКL 125 HTB, BTC (up to 50 W/m)
TKR 125 HTР, HTM, HTA
TKW 190 BTX, BTC (over 50 W/m)
Ordering informationТКn kit, where n is termination kit .
Approval detailsCertificate of conformance to the Customs Union Technical Regulation No . ТС RU С-RU .ГБ05 .В .00528 with explosion-protection marking 1Ex e IIC T3 . . .T6 Gb X
IEC certificate of conformity IEC Ex for self-regu-lating electric heating tapes with kits No . IECEx CCVE 12 .0002X
89
Ind
ustr
ial h
eati
ng s
yste
ms
KITS FOR ELECTRICAL HEATING TAPES
KIT FOR ELECTRICAL HEATING TAPES TKT/M
DescriptionTKT/M kit is designed to connect the self-regulating elec-trical heating tape and the installation wire directly on the object site, in safe and explosion hazardous areas, at max-imum exposure temperature 125 °C . TKT/M kit includes heat shrinkable tubes made basing on polyethylene composite and crimp-type connectors .
Ordering informationTKT/M kit .
Approval detailsCertificate of conformance to the Customs Union Technical Regulation No . ТС RU С-RU .ГБ05 .В .00528 with explosion-protection mark-ing 1Ex e IIC T3 . . .T6 Gb X
IEC certificate of conformity IEC Ex for self-regu-lating electric heating tapes with kits No . IECEx CCVE 12 .0002X
KIT FOR ELECTRICAL HEATING TAPES TKL/j, TKR/j
DescriptionStandard kits for entry of one end of self-regulating electri-cal heating tapes into connection boxes and boxes with light indication (PTB 401-IS, PTB 402-IS) .
The kit includes crimp-type tips, tube for earthing wire, or-ganic-silicon sealing for cable entry M25, adhesive sealant 10 ml .
Kit vs. heating tape type
Ref . type of the kit
Maximum expo-sure tempera-ture, °C
Ref . type of self-regulating heating tape
ТКL/j 125 HTB, BTC (up to 50 W/m)
TKR/j 125 HTР, HTM, HTA
TKW/j 190 BTX, BTC (over 50 W/m)
Ordering informationТКn kit, where n is termination kit type .
Approval detailsCertificate of conformance to the Customs Union Technical Regulation No . ТС RU С-RU .ГБ05 .В .00528 with explosion-protection mark-ing 1Ex e IIC T3 . . .T6 Gb X
IEC certificate of conformity IEC Ex for self-regu-lating electric heating tapes with kits No . IECEx CCVE 12 .0002X
90
Industrial heating
systems
KIT FOR ELECTRICAL HEATING TAPES СР-6
KIT FOR ELECTRICAL HEATING TAPES СР-7
Accessories for the TEPLOMAG system installation
DescriptionCP-6 kit is designed to connect self-regulating electrical heating tapes of HTM, HTA, HTP and BTC types (up to 50 W/m) with outer jacket made of thermoplastic elasto-mer and fluoroplastic .
Maximum exposure temperature is 125 °C .
CP-6 kit includes heat shrinkable tubes made basing on polyethylene composite, solder, copper braid, fluoroplas-tic tape .
DescriptionCP-7 kit is designed to connect high temperature self-regulating electrical heating tapes of BTC type (over 125 °C) and BTX with outer jacket made of fluoroplastic featuring maximum exposure temperature 190 °C . CP-7 kit contains heat shrinkable tubes made basing on fluoro-polymer, solder, tinned copper braid, fluoroplastic tape and adhesive sealant .
Ordering informationSplice kit СР-6 .
Ordering informationSplice kit СР-7 .
Approval detailsCertificate of conformance to the Customs Union Technical Regulation No . ТС RU С-RU .ГБ05 .В .00528 with explosion-protection mark-ing 1Ex e IIC T3 . . .T6 Gb X
IEC certificate of conformity IEC Ex for self-regu-lating electric heating tapes with kits No . IECEx CCVE 12 .0002X
Approval detailsCertificate of conformance to the Customs Union Technical Regulation No . ТС RU С-RU .ГБ05 .В .00528 with explosion-protection mark-ing 1Ex e IIC T3 . . .T6 Gb X
IEC certificate of conformity IEC Ex for self-regu-lating electric heating tapes with kits No . IECEx CCVE 12 .0002X
91
Ind
ustr
ial h
eati
ng s
yste
ms
DEVICE FOR CABLE ENTRY UNDER THERMAL INSULATION LEK/U
ACCESSORIES FOR INSTALLATION OF TEPLOMAG SYSTEM
Ordering informationDevice for cable entry under thermal insulation LEK/U .
Approval detailsThe products are not subject to mandatory certification .
Supply kitThe kit includes:
Name Q-ty
1 . Lock nut 1
2 . Metal plate 1
3 . Self-tapping screws 4
4 . Gland body GW50416 1
5 . Sealing ring of the gland 1
6 . Cable sealing ring (2 types) 1
7 . Washer 1
8 . Gland head 1
STRAPS TO FIX BRACKETS OF CONNECTION BOXES TO THE PIPE
Ordering information1. Strap PFS/n (where n is the length of the strap, m)
2. Strap PFS/30 is used with fastening elements .
Approval detailsThe products are not subject to mandatory certification .
DescriptionName Length, m
PFS/3 3
PFS/30 30
1
27
8
3
5
6
4
92
Industrial heating
systems
PВКР1 ПЛ .РТВ 0606 .-10
ПЛ .РТВ 0606 .-20
КР101КР3
BRACKET TO FIX CONNECTION BOXES TO THE PIPE AND ONTO VESSELS
SELF-ADHESIVE FIXING TAPE
Accessories for the TEPLOMAG system installation
Ordering informationBracket PВ* .
Bracket КР-1** .
Bracket КР-3** .
Bracket КР-101** .
Bracket ПЛ .РТВ 0606 .-10* .
Bracket ПЛ .РТВ 0606 .-20* .
_________* The brackets are fixed by means of two fixing straps of PFS type (to be supplied
as per separate order) .** The bracket is fixed by means of welding .
Approval detailsThe products are not subject to mandatory certification .
Approval detailsCertificate of conformance of Voluntary Certifica-tion System in the field of fire safety No . НСОПБ .RU .ПР037 .Н .00152 .
ApplicationSelf-adhesive fixing tape to fasten the heating tapes to the pipes, where high temperatures are maintained .
To be used with heating tapes of all types .
Technical dataLength 33 m
Width 11 mm
Stability against constant temperature effect of 200 °С
Recommended installation temperature starting from –15 °C and higher
Adhesive material modified silicone
Ordering informationFixing tape FT/HTМ
93
Ind
ustr
ial h
eati
ng s
yste
ms
SELF-ADHESIVE ALUMINUM FIXING TAPE
FIXING BAND
«ATTENTION ELECTRICAL HEATING» MARKER
ACCESSORIES FOR INSTALLATION OF TEPLOMAG SYSTEM
Approval detailsThe products are not subject to mandatory certification .
Approval detailsThe products are not subject to mandatory certification .
Approval detailsThe products are not subject to mandatory certification .
ApplicationThe self-adhesive aluminum fixing tape is used to fasten the heating tape to flat surfaces, for example, flat surfaces of vessels; to fix the heating tape to bodies of valves/pumps . The self-adhesive aluminum fixing tape can be also used as a gasket under heating tapes laid on plastic tubes .
ApplicationThe fixing band is used to fasten the cable to the vessel .
Technical dataLength: 50 m
Width: 50 mm
Stability against constant temperature effect of 110 °С
Recommended installation temperature starting from –5 °C and higher
Adhesive material acrylic
Ordering informationSelf-adhesive aluminum fixing tape
Ordering informationFixing tape 25 (where 25 is the pitch of the fixing element location, mm)
Ordering informationMarker «Attention Electrical Heating»
25 mm
19 m
m
55 m
m
ATTENTIONELECTRICAL HEATING!
Special systems and technologies, LLCTel.: (495) 728-80-80
ELECTRICAL HEATERSARE INSTALLED UNDER HEAT INSULATION
145 mm
95
Ind
ustr
ial h
eati
ng s
yste
ms
Automated control systems
96
Autom
ated control system
s
Description EHACS automatically controls electric heating using sig-nals received from temperature sensors . Analyzing the received data, the system automatically switches heating on or off . There are possible both two-position control based on surface temperature and proportional control based on air temperature . Temperature settings can be corrected in the process of the system operation .
In the EHACS system there are used programmable logic controllers (PLC), discrete and analog signals input-out-put modules, operator’s panel and serial interface mod-ule RS232/RS485 . Regardless of the complexity and di-mensions of the object, EHACS usage will allow for significant improvement of operating characteristics of electric heating systems with regard to features of control and regulation, protection and monitoring, and in case of usage of integrated APCS on the object it will comple-ment it .
Purpose maximum ease of control and adjustment;
promptness and high quality of decisions on electrical heating control;
increase in reliability of thermal conditions; quick elim-ination of pre-fault and fault conditions followed by case analysis;
equipment operation diagnostics and repair cost re-duction ;
providing the staff with retrospective process data (logging, event record base, data calculation for equipment operation analysis);
record, control and possibility to influence on power consumption .
ELECTRICAL HEATING AUTOMATED CONTROL SYSTEMS
StructureEHACS consists of:
Power cabinets (PC);
Automatic equipment cabinets (AEC);
Temperature sensors
Set of equipment for automated control, monitoring, data collection and transfer to the operating automated process control system (APCS) .
EHACS
Power cables to heating sections
Power cables to heating sections
Control cables to temperature sensors
Control cables to temperature sensors
Place of automatic equipment cabinets installation for electric heating system
Management Communication cable
Management
PC PCPC PCPC PCAEC AECData storage server
Manager’s workplace
97
Aut
omat
ed c
ontr
ol s
yste
ms
ELECTRICAL HEATING AUTOMATED CONTROL SYSTEMS
Example of user display of EHACS operator’s panel
Advantages optimal way of electrical heating control and
maximum power-saving due to algorithm fitting to a specific site object;
electrical heating system remote control and remote management;
acquisition of a wide range of information (temperature, load current, supply mains voltage, power consumption, emergency situations and others);
modernization of electrical heating control systems of previous generations;
reduction of operation costs due to remote data collection, control and regulation of power consumption;
improved protection of process flows of hazardous production facilities due to authorization-based access system and recording of signals, alarms, failures and personnel operations;
ease of operation: all the software, user interfaces, instructions are made in Russian;
start-up and commissioning and finishing adjustment of the systems provided by qualified specialists on-site, adjustment is conducted taking into consideration the requirements of operating personnel and process service department;
a possibility of control system scaling with connection of new input-output modules;
a possibility of correction of logical interrelationship between sensor and heated object from user terminal (touch screen operator’s panel).
system status identification (heating on/off ) by inter-rogating discrete input modules;
input-output modules output relays status manage-ment based on measurement results (electric heating systems switching on-off, system status notification)
In AEC PLC connection with input-output modules is ef-fected by means of internal bus . PLC is a slave controller in the MODBUS network and performs the following functions:
calculation of current values of measured temperatures;
98
Autom
ated control system
s
EHACS integration into Customer’s APCSEHACS is integrated into Customer’s APCS by way of im-plementation of data transfer protocol Modbus TCP or Modbus RTU protocol . Data in all AEC are accumulated in the data storage server and transferred from there to
the manager’s automated work place (AWP) . For data transfer it is possible to use both cabling and fibre optic communications systems as well as radio channels .
Example of cabinets versions
Structure chart of EHACS integration into Customer’s APCS
Automatic equipment cabinets (AEC)
ModBus TCP
ModBus RTUModBus RTU
Management
PCPC
PCPC
PCPC
AECAECPLCPLC Analog input modulesAnalog input modules
Discrete input-output modules
Discrete input-output modules
Discrete input-output modules
Discrete input-output modules
Discrete input-output modules
Discrete input-output modules
Data storage server
Manager’s workplace
99
Aut
omat
ed c
ontr
ol s
yste
ms
Power cabinet (PC)
Ordering informationAll EHACS systems are developed and manufactured as per individual design .
100
Autom
ated control system
s
Purpose PT-400 controller is used as a part of the electric heating systems for pipelines as well as with de-icing systems . The controller is designed for object temperature measure-ment and heating process control . Measurement and control are effected by 4 independent channels within the temperature setting range from -60 to +500 °C . The accuracy of temperature maintenance is ±1 °С, display of indication accuracy is 0 .1 °C .
Operating principleThe temperature maintenance control is of relay-type, the control method is two-positional (on-off ), load current via own relay contacts is up to 6 A . The upper and the lower limits of the temperature maintenance range should be set at the device installation .
FeaturesThe controller features high temperature measurement accuracy together with high interface immunity of the temperature measurement channels . Thanks to the above, the device may be conveniently used when the sensors are removed from the device within a distance of up to 100 m, at that 8 sensor types may be used .
Application The controllers of this type are widely used for monitoring and maintenance of the preset temperature value of pro-cess pipelines and vessels . PT-400 devices are also very easy to use in freezing chambers where ground heating under the chamber floor prevents the ground from freez-ing thus preventing floor lifting . Four control channels al-low to control several chambers from one device .
Ease of operationThe built-in display facilitates the device checkup and adjustment . Four control buttons located on the front panel provide user friendly interface .
InstallationThe controller’s construction provides its installation in a control cabinet . The device is designed for DIN-rail mount-ing (6 modules) .
Reliability100% of the devices pass factory tests . The preset param-eters can be stored in the device nonvolatile memory .
РT-400Electronic temperature controller for four channel temperature maintenance
Control of 4 independent channels
High accuracy of temperature measurement
High level of interference protection of measurement channels
Maximum remoteness of temperature sensors is up to 100 m
Simultaneous indication of temperatures by 4 channels
Temperature setting range is from –60 to +500 °C
Built-in matrix display
Easy setting of controlled temperatures
DIN-rail mounting
RS485 communications interface, MOD_BUS/RTU
101
Aut
omat
ed c
ontr
ol s
yste
ms
ELECTRONIC TEMPERATURE CONTROLLER
Technical data
Temperature setting range –60 °C . . . +500 °C
Measurement channels number 4 channels
Control channels number 4 channels
Temperature measurement accuracy 0,5 %
Temperature indication accuracy 0,1 °C
Types of temperature sensors used* (the type of the connected sensor is to be set in the device adjustment menu, separately for each channel)**
Type0-Pt100, W100
=1 .3850,Type1-Cu100, W
100=1 .4260,
Type2-Cu100, W100
=1 .4280,Type3-Cu50, W
100=1 .4260,
Type4-Cu50, W100
=1 .4280,Type5-Pt50, W
100=1 .3850,
Type6-Pt100, W100
=1 .3910,Type7-Pt50, W
100=1 .3910 .
* – It is not included in the delivery kit, it should be ordered separately .
** – Type 4 – factory preset .*** – Thermoresistance, connected according to three-wire circuit, by
cable with recommended cross-section of 2 .5 mm2 at least .
WarrantyWarranty period of operation is 1 year from the date of sale .
Ordering information
Connection diagramApproval detailsCertificate of conformance to the requirements of Customs Union Technical Regulation No . 004/2011 «On safety of low-voltage equipment» and No . 020/2011 «Electromagnetic compatibility of equipment» . No . ТС RU C-RU .ME67 .B .00064
1. Electronic temperature controller РТ-400 .
2. Temperature sensor (resistance thermometer, 1 pcs for each measurement channel) . The sensor type to be clarified at ordering .
Interface, communication protocol 9,600 bit/s RS485, MOD_BUS/RTU
Maximal sensor remoteness from the controller*** up to 100 m
Data logging Available, nonvolatile
Maximum control relay current 6 A, 220 VAC
Enclosure protection rating IP20
Operating temperature 0 °C . . . +40 °C
Power supply 220 VAC +10/-15 % , 50 Hz
Overall dimensions 105×90×66 mm
Weight 450 g
control relays contacts
Power 220 VAC
102
Autom
ated control system
s
Purpose PT-410 electronic controller is designed for temperature measurement and preset temperature maintenance control . Its application range includes industrial electric heating of pipelines, vessels, various volume capacities, etc . Also domestic application of the controller is possible for heating of pipes and capacities . The device ensures a possibility of temperature measurement by means of measuring sensors of thermal resistance type .
Operating principleOutput device control logic ensures optimal heating maintenance process . The temperature maintenance method is “proportional type control” . The user sets a con-troller performance characteristic by entering two tem-peratures and percentages of the total system output corresponding to them (-10 °C, 100 % and +80 °C, 10 % in an example shown in the picture) . The controller calcu-lates its temperature-power curve basing on these data:
Then the device is automatically switched to the temper-ature stabilization mode . As a result, the pipe temperature is kept within the preset range irrespective of changes in ambient air temperature with energy consumption being as low as practicable .
FeaturesThe controller features high temperature measurement accuracy together with high interface immunity of the temperature measurement channels . Thanks to the above, the device may be conveniently used when the sensors are removed from the device within a distance of up to 100 m, at that 8 sensor types may be used .
Application The device is used stationary, along with ambient air and heated object temperature sensors (optionally, at discre-tion) . During the device installation it is necessary to input lower and upper limits for the temperature maintenance range using 4 control buttons located on the front panel . These settings are enough for normal operation of PT-410 controller .
РT-410Electronic temperature controller for pipeline heating systems
Automatic regulation of heating power depending on ambient air temperature and heated surface temperature
Saving up to 40% of electric energy due to efficient control of the heating system
Thermal process control capability within the temperature range from -200 °C to +1,100 °C to an accuracy of ±0.5°C
Conversion of heating system based on series resistance cables to a self-regulating one
Automatic adjustment to heat capacity of an individual heated surface
External sensor removed from the device within a distance of up to 100 m
Automatic pipe (or other heated surface)overheating or overcooling protection with forced heating switch ON or OFF correspondingly
Keeping the preset parameters in a nonvolatile memory as long as necessary even if electric power is off
Supply voltage 230 VAC 50–60 Hz DIN-rail mounting Current air and pipe temperature indication on a
LC-indicator Signaling on emergency and abnormal situations Easy installation and adjustment
P, relative output power of the heating system
temperature, Т °С
103
Aut
omat
ed c
ontr
ol s
yste
ms
Technical data
Temperature setting range -200 °C . . . +1100 °C*
Temperature measurement accuracy 0,5 %
Temperature indication accuracy 0,1 °C
Measurement channels number
2 channels:– air temperature measure-
ment channel R1– surface temperature meas-
urement channel R2 .
Output relay channels2 channels:– control channel . Relay K1 .– emergency channel . Relay K2
Analog output DC voltage: 0 . . .10 V
Maximum relay current 16 A, 230 VAC . (control relay and emergency relay)
Enclosure protection rating IP20
Operating temperature +5 °C . . . +40 °C
Power supply 230 VAC +10/-15 % , 50–60 Hz
Consuming power not more than 5 W
Mounting option in control cabinet DIN-rail, 4 modules
Overall dimensions 70×90×66 mm
Weight 300 g
Types of temperature sensors used**The sensors are defined by the parameter W100***
Type0-Pt100, W100
=1 .3850 (-200 °C … +850 °C),Type1-Cu100, W
100=1 .4260 (-50 °C … +200 °C),
Type2-Cu100, W100
=1 .4280 (-200 °C … +200 °C),Type3-Cu50, W
100=1 .4260 (-50 °C … +200 °C),
Type4-Cu50, W100
=1 .4280 (-200 °C … +200 °C),Type5-Pt50, W
100=1 .3850 (-200 °C … +850 °C),
Type6-Pt100, W100
=1 .3910 (-200 °C … +1100 °C),Type7-Pt50, W
100=1 .3910 (-200 °C … +1100 °C) .
* Depends on type of used temperature sensor . ** It is not included in the delivery kit, it should be ordered separately . *** W
100 – ratio of sensor’s resistance at 100 °C to its resistance at 0 °C .
WarrantyWarranty period of operation is 1 year from the date of sale .
Ordering information
Connection diagram
1. Electronic temperature controller РТ-410 .
2. Temperature sensor (resistance thermometer, 1 pcs for each measurement channel) . The sensor type to be clarified at ordering .
Ease of operationThe built-in display facilitates the device checkup and adjustment . Four control buttons located on the front panel provide user friendly interface .
InstallationThe controller’s construction provides its installation in a control cabinet . The device is designed for DIN-rail mount-ing (4 modules) .
Reliability100% of the devices pass factory tests . The preset param-eters can be stored in the device nonvolatile memory .
Approval detailsCertificate of conformance to the requirements of Customs Union Technical Regulation No . 004/2011 «On safety of low-voltage equipment» and No . 020/2011 «Electromagnetic compatibility of equipment» . No . ТС RU C-RU .ME67 .B .00064
ELECTRONIC TEMPERATURE CONTROLLER
20 21 23 241513L N
СЕТЬ РЕЛЕK1
РЕЛЕK2
t°R1 t°R2
6 7 9 10 11 125321
ДАТЧИК ДАТЧИК
ВЫ
Х. 1
ОБ
Щ.
ВЫ
Х.2
ОБ
Щ.
POWER RELAY
SENSOR SENSOR
OU
T 2
OU
T 1
COM
MO
N
COM
MO
N
RELAY
104
Autom
ated control system
s
Purpose PT-420 electronic controller is designed for temperature measurement and preset temperature maintenance control . Its application range includes industrial electric heating of pipelines, vessels, various volume capacities, etc . Also domestic application of the controller is possi-ble for temperature maintenance in electric heating sys-tems . The device ensures a possibility of temperature measurement by means of measuring sensors of ther-mal resistance type .
Operating principleThe controller realizes two-position (on-off ) relay control method . The upper and the lower limits of the tempera-ture maintenance range should be set at the device in-stallation .
FeaturesThe controller features high temperature measurement accuracy together with high interface immunity of the temperature measurement channels . Thanks to the above, the device may be conveniently used when the sensors are removed from the device within a distance of up to 100 m, at that 8 sensor types may be used .
Application The controllers of this type are widely used for monitor-ing and maintenance of the preset temperature value of process pipelines and vessels . PT-420 devices are also very easy to use in freezing chambers where ground heating under the chamber floor prevents the ground from freezing, thus preventing floor lifting . Two control channels allow to control several chambers from one device .
Ease of operationThe built-in display facilitates the device checkup and ad-justment . Four control buttons located on the front panel provide user friendly interface .
InstallationThe controller’s construction provides its installation in a control cabinet . The device is designed for DIN-rail mount-ing (4 modules) .
Reliability100% of the devices pass factory tests . The preset param-eters can be stored in the device nonvolatile memory .
РT-420Electronic temperature controller for two-channel temperature maintenance
2 independent control channels
High temperature measurement accuracy
High interference immunity of measurement channels
External sensors removed from the device within a distance of up to 100 m
Simultaneous display of temperatures for 2 channels
Simultaneous display of heating state for 2 channels
Thermal control capability within the temperature range from -200 °C to +1,100 °C
DIN-rail mounting
Equipped with built-in matrix display
Easy adjustment of controlled temperatures
105
Aut
omat
ed c
ontr
ol s
yste
ms
Technical data
Temperature setting range –200 °C . . . +1100 °C*
Temperature measurement accuracy 0,5 %
Temperature indication accuracy 0,1 °C
Measurement channels number 2 channels
Output relay channels 2 channels
Analog output DC voltage: 0 . . .10 V
Maximum relay current 16 A, 230 VAC
Enclosure protection rating IP20
Operating temperature +5 °C . . . +40 °C
Power supply 230 VAC +10/-15 % , 50–60 Hz
Consuming power not more than 5 W
Mounting option in control cabinet DIN-rail, 4 modules
Overall dimensions 70×90×66 mm
Weight 300 g
Types of temperature sensors used**The sensors are defined by the parameter W100***
Type0-Pt100, W100
=1 .3850 (-200 °C … +850 °C),Type1-Cu100, W
100=1 .4260 (-50 °C … +200 °C),
Type2-Cu100, W100
=1 .4280 (-200 °C … +200 °C),Type3-Cu50, W
100=1 .4260 (-50 °C … +200 °C),
Type4-Cu50, W100
=1 .4280 (-200 °C … +200 °C),Type5-Pt50, W
100=1 .3850 (-200 °C … +850 °C),
Type6-Pt100, W100
=1 .3910 (-200 °C … +1100 °C),Type7-Pt50, W
100=1 .3910 (-200 °C … +1100 °C) .
* Depends on the type of the temperature sensor used . ** It is not included in the delivery kit, it should be ordered separately . *** W
100 – ratio of sensor’s resistance at 100 °C to its resistance at 0 °C .
WarrantyWarranty period of operation is 1 year from the date of sale .
Ordering information
Connection diagram
1. Electronic temperature controller РТ-420 .
2. Temperature sensor (resistance thermometer, 1 pcs for each measurement channel) . The sensor type to be clarified at ordering .
Approval detailsCertificate of conformance to the requirements of Customs Union Technical Regulation No . 004/2011 «On safety of low-voltage equipment» and No . 020/2011 «Electromagnetic compatibility of equipment» . No . ТС RU C-RU .ME67 .B .00064
ELECTRONIC TEMPERATURE CONTROLLER
20 21 23 241513L N
СЕТЬ РЕЛЕK1
РЕЛЕK2
t°R1 t°R2
6 7 9 10 11 125321
ДАТЧИК ДАТЧИК
ВЫ
Х. 1
ОБ
Щ.
ВЫ
Х.2
ОБ
Щ.
POWER RELAY
SENSOR SENSOR
OU
T 2
OU
T 1
COM
MO
N
COM
MO
NRELAY
106
Autom
ated control system
s
Application PTM-2000 controller is used as a part of industrial elec-tric heating systems of pipelines, vessels . The controller is intended for temperature measurement and control of the object heating .
Control features5 control algorithms are provided by the device .
1 . «TUBE» – two-position control by 4 channels based on ON and OFF temperature settings .
2 . «TUBE+» – proportional control by 4 channels (based on ambient air temperature with the surface tempera-ture control) .
3 . «ROOF/ROAD» – control of de-icing systems for roofs and open areas by 4 zones .
4 . «TIMER» – control of power output percentage by 4 independent channels by time period .
5 . «MEASURER» – Measuring and indication of 8 tem-perature channels .
РTМ-2000Electronic temperature controller for eight-channel temperature monitoring and four-channel temperature maintenance .
4 independent control channels
High temperature measurement accuracy
High interference immunity of measurement channels
External sensors can be placed at max. distance of 1,000 m
Simultaneous display of temperatures for 4 channels
Thermal control capability within the temperature range from -100 °C to +600 °C
Equipped with built-in LED-display
Easy adjustment of controlled temperatures
Power supply 230 VAC, 50–60 Hz
DIN-rail mounting
Communication interface RS485, MOD_BUS/RTU
The preset parameters are saved in nonvolatile device memory
Technical data
Temperature setting range
–100 °C . . . +600 °C for normal-ized signal 4…20 mА–55 °C . . . +60 °C (+125 °C**) for temperature sensor TST01
Measurement channels number 4(8) channels
Control channels number 4 channels
Temperature measurement accura-cy 0,5 %
Temperature indication accuracy 0,1 °C
Types of temperature sensors used* (the type of the connected sensor is to be set in the device adjust-ment menu, separately for each channel)
TST01, TSP01, TSP02, TSW01 Normalized signal 4…20 mА
Interface, communication protocol RS485, MOD_BUS/RTU
Maximal sensor remoteness from the controller
100 m for temperature sensor TST01up to 1,000 m for normalized signal 4…20 mА
Maximum control relay current 6 A
Power consumption 12 W
Enclosure protection rating IP20
Operating temperature +5 °C . . . +45 °C
Power supply 90–245 VAC, 50–60 Hz
Weight 450 g
Overall dimensions 160×90×60 mm
Permissible relative air humidity 80 %
Mounting type DIN-rail, 9 modules
* – The temperature sensor is not included in the delivery kit, it should be ordered separately . The sensor’s parameters are provided in its Technical Certificate .
** – For sensor in silicone enclosure .
107
Aut
omat
ed c
ontr
ol s
yste
ms
WarrantyWarranty period of operation is 2 years from the date of sale .
Ordering information
Function of contacts
Approval detailsCertificate of conformance No . РОСС RU .AB87 .B03180 .
1. Electronic temperature controller РТМ-2000 .
Joint products depending on heating system’s appli-cation, ordered separately:
2. Temperature sensor (resistance thermometer) TST01– 1 pc . for each measuring channel .
3. Water sensor TSW01 (for de-icing systems) .
4. Precipitation sensor TSP03-D, TSP01 or TSP02 (for de-icing systems) .
5. Power supply unit for precipitation sensor BPDO (for de-icing systems) .
Operation features The controller features high temperature measurement precision as well as interference immunity of the tem-perature measurement channels . Thus, it can be success-fully used at significant distances (up to 1,000 m) from the controlled area .
The PTM-2000 controllers are widely used for monitoring and maintenance of set temperatures of process pipe-lines and vessels as well as in warm floor systems .
The controller ensures the temperature measuring by use of temperature sensors, and ensures a fast integra-tion into APCS (Automated Process Control System) by use of digital data transfer interface RS485, over the pro-tocol MOD_BUS/RTU . The control of electrical heating system is ensured by output relay channels . The control-ler has a liquid crystal display for to show a present opera-tion status of the system and operation parameter set-tings .
Design The controller is designed for installation in a control cabinet . It is mounted on DIN rail 35 mm (9 modules) .
The controller realizes two-position (on-off ) relay method, load current via own relay contacts is up to 6 A . The upper and the lower limits of the temperature maintenance range should be set at the device installation .
Reliability100% of the devices pass factory tests . The preset param-eters can be stored in the device nonvolatile memory .
АВ87
ELECTRONIC TEMPERATURE CONTROLLER
28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 5227L N A B
+5V GND
90...245VAC RS485 62
0 О
hм12
0 О
hм
RLIN1
K0 K1 K2 K3 K4 K5
+24V
GN
D
GN
D
GN
D
21 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 265 63 4D2D1 D3 D4 A2A1 P2P1A3 A4 W2W1 W3 W4
TST01 4...20mA PREC WATER
РТМ-2000
108
Autom
ated control system
s
ApplicationThe unit is used as a part of electrical heating systems for pipelines and vessels . It is also possible to use the product in other automatic control systems .
Application of the unit in explosion hazardous zones must be performed in strict accordance with the explo-sion protection marking .
t
t
t
t
Explosion hazardous zone
Spark-safe circuitMeasuring transducer unit
Safe area
Controller
Component parts and arrangement1 – enclosure of the measuring transducer unit
2 – armored cable entry, brass M25
3 – locking nut M25
4 – earthing tag, brass M25
5 – sealing ring М25
6 – blanking plug М25
7 – unarmored cable entry, plastic, M25
8 – cable gland GP25
9 – modular measuring transducer
РТВ/MMPMeasuring transducer unit for automation systems
Up to 8 independent measurement channels
Connection line length between a thermostat (controller) and the unit: up to 1,000 m
Installation in explosion hazardous zone
Minimum operating temperature: –50 °C
Protection grade: IP66
Purpose The primary purpose of the measuring transducer unit is transformation of signals received from:
– resistance temperature detectors (RTD),
– thermoelectric transducers (TT),
– transducers with unified output signals
into unifies signals (0 ÷ 5) mA or (4 ÷ 20) mA and also input to control computer or controller of measured temperature or current values, received from various sensors .
109
Aut
omat
ed c
ontr
ol s
yste
ms
РТВ – designation of the product’s plastic enclosure
10 – dimension-type of the enclosure (250×255 mm)ИПМ – modular measuring transducer unitY – number of transducers (from 1 to 8)ZZ – number and type of input line entries (П – plastic entries, Б – armored cable entries)WW – number and type of output line entries (П – plastic entries, Б – armored cable entries)
MEASURING TRANSDUCER UNIT
Technical data
Parameter name Value
Explosion protection marking 1Ex ia [ia Ga] IIC T6 Gb X
Ingress protection grade according to GOST 14254-96 IP66
Ambient temperature range, °C -50 … +50
Maximum input voltage, Um, V 27
Electrical equipment class as regards to methods of human protection against electric-shock hazard according to GOST 12 .2 .007 .0-75
III
Operating temperature, °C -50 … +50
Storage temperature, °С -50 … +50
Electrical spark safety parameters of the product
Maximum input voltage, Ui, V 24
Maximum input current, Ii, mA 120
Maximum input power, Pi, W 0,75
Warranty The product service time is 10 years .
The manufacturer has warranty obligations for the deliv-ered product within 2 years on condition that all instal-lation and operation conditions specified in product’s technical documentation are observed .
Approval detailsCertificate of conformance to the require-ments of Customs Union Technical Regulation No . 012/2011 on «Safety of
equipment for operation in explosion hazardous environment» with explosion protection marking 1 Ex ia [ia Ga] IIC T6 Gb X № ТС RU С-RU .ГБ05 .В .00280
Ordering informationExample:
Measuring transducer unit РТВ10/ИПМY-ZZ/WW
Maximum internal inductance, Li, mH 0,1
Maximum internal capacitance, Ci, nF 22
Maximum output voltage, Uo, V 6,2
Maximum output current, Io, mA 10
Maximum external inductance, Lo, mH 200
Maximum external capacitance, Co, uF 10
Overall dimensions, not more than, mm– length – width – depth
250 255 120
Weight, not more than, kg 3
110
Autom
ated control system
s
PE
Q
4
4
1
2
2
L1 N
Purpose Explosion proof overhang mounting thermostats are designed for thermal processes control and monitoring . They can be used directly in explosion hazardous zones (zone 1 and zone 21) .
Explosion proof capillary thermostat for overhang mounting
Technical data
Control range, °C 0 . . . +200
Differential gap, % 2,5
Capillary length, mm 1000
Capillary material stainless steel
Sensing element diameter, mm 4
Switching capacity at 230 VAC, A 25
Ambient temperature (at operation and storage), °C from -60 to +50
Ingress protection index acc . to GOST 14254-96 IР65
Climatic version according to GOST 15150-69 UHL1 (boreal climate 1)
Weight, kg not more than 1 .7
exTHЕRM-AT
Brief description The thermostats are delivered in form of SТW devices (temperature limit switches) and operate based on ther-mal expansion of a liquid or gas .
Electric switching unit of the device is made in form of a microswitch located inside a plastic enclosure .
The thermostats meet RoHS requirements and do not contain cadmium .
The devices can operate at extremely low temperatures .
Electric circuit diagramPrinciple of operationWhen the temperature of the sensing element exceeds the preset value, the microswitch operates via transfer mechanism and the electric circuit becomes closed or opened . When the temperature drops below the preset value (taking into account a differential gap), the micros-witch returns to its initial position .
It is allowed to input armored cables into the thermostat with sealing of their outer jacket above the armor .
Cable entry typeplastic cable gland М20×1,5 with blanking plug for opening М25×1,5
Input cables diameter, mm from 6 to 17
Connected conductors cross-section, mm2 up to 4 inclusive
Explosion protection marking 1Ех de llС T4/Т5/T6 Gb
111
Aut
omat
ed c
ontr
ol s
yste
ms
CAPILLARY THERMOSTAT
Ordering informationApproval detailsCertificate of conformance to the require-ments of Customs Union Technical Regula-tion No . 012/2011 on «Safety of equipment for operation in explosion hazardous environment» № ТС RU С-DE .МЕ92 .В .00443
Thermostat exTHERM-AT with the scale 0 . . . +200 °C, type 60/00588595
Overall dimensions and mounting dimensions
PE
Q
4
4
1
2
2
L1 N
120
Front view Mounting dimensions (back view)
82∅ 64 openings
122
91,5
10
6
113
Ind
ustr
ial h
eati
ng s
yste
ms
Switchboard equipment
114
Switchb
oard eq
uipm
ent
FeaturesDistribution boards of MDB series are used as a compo-nent part of Package Transformer substation 6 (10 kW)/ 0 .4 kW (low voltage element), input devices of industrial enterprises and residential buildings .
Design of MDB foresees one or two entries and an addi-tional entry from diesel-electric engine . The boards are made of metal, one or multi-sectional, of unilateral or two-lateral maintenance . Each section can be equipped with protective panels (plastrons) and doors . Multi-sec-tional boards are easy to assemble and disassemble into parts convenient for transportation . Cable and bus entries are provided in boards . An entry can be located both on top and at the bottom . Output can be performed both through sections containing equipment and through special sections, what is especially convenient for unilat-eral maintenance boards . Power bus lines are manufac-tured of calibrated copper strip .
MDBDistribution boards of MDB series rated for operating currents up to 3,200 A intended to protect against overloads and short-circuiting, for energy accounting and infrequent urgent commutations of electrical circuits .
Input from Package Transformer Substation and distribution of electrical power
Protection against single and multiphase short circuiting, overloads and leaks
Commercial and technical accounting of power consumption
Remote control and management of MDB electrical parameters
Sectioning of collecting buses to ensure safe maintenance operations
Automatic load transfer (ALT section) for two and three entry board; ALT functions basing on microprocessor units analyzing the current system state
Warning lights indicating operation and emergency system state
Technical dataRated current, In from 400 to 3,200 A
Surge current, Ikp up to 120 kA
Rated three phase voltage, Un 380 V
Insulation voltage, Ui 1,000 V
Rated frequency, f 50 Hz
Protection rating IP31 or IP54
Dimensions of one section (height × width × depth), mm
1,800–2,200 × 600–1,200 × 600–1,000
Climatic version UHL4 (boreal climate 4)
Design version Intended for installation on the floor only
Ordering informationMDB are manufactured in accordance with one-line dia-gram, specification and questionnaire submitted by the Customer . When placing an order, the Customer should submit the following technical documents depending on the order type:
1. To make an order according to the CUSTOMER’s re-quirements, filled-in questionnaires should be submit-ted . In this case an equipment design work is usually required to be performed upon agreement .
2. To order type items, filled-in questionnaires should be submitted obligatory indicating No . of type diagrams, types of bodies used (intended to be hinged/built-in/installed on the floor, body material, protection rating IP), manufacturers of component parts, other techni-cal parameters .
3 . To make an order according to the Customer’s project, project design documents are required: one-line dia-gram or circuit scheme, component parts specifica-tion, drawings . When placing an order for control cabi-nets and automatic equipment, control circuit (functional diagram) is additionally required .
CompletenessThe basic arrangement of the MDB includes automatic power switches, circuit breakers, boards’ bodies and mounting elements Schneider Electric, ABB, Hager .
Operating conditionsHeight above sea level shall not exceed 2,000 m
Environment Non-explosive and containing no corrosive vapors and gases concentrated enough to destroy metal and insulation
Operating temperature
from -5 °C to +45 °C (MDB should be located in special enclosed switchboard rooms)
MAIN DISTRIBUTION BOARDS
Approval detailsCertificate of conformance to the Customs Union Technical Regulation for complete low voltage cabinets № ТС RU C-RU .АЮ64 .B .01029
115
Swit
chb
oard
eq
uip
men
t
FeaturesISDA protects against short circuits, overloads and leak-ages . Incoming supply distribution assemblies are used for non-frequent urgent commutations of electrical cir-cuits .
Incoming supply distribution assemblies consist of unilat-eral maintenance sections and assembled in metal case . ISDA can consist of one or several cabinets of on-floor ver-sion . If ISDA is connected to two independent power sources, it is possible to assemble ISDA terminal panels having automatic switch in one cabinet with a baffle be-tween sections . Depending on Technical Requirements the ISDA is completed with automatic switches, counting devices and other equipment .
ISDAIncoming supply distribution assembly intended to input, register and distribute electric power and to protect users of power mains featuring rated voltage up to 380 VAC, 50 Hz and deadly earthed neutral
Entry for three phase power mains 380 V Distribution of electrical power over three phase
and/or one phase circuits Protection of circuits against overloads and short
circuit currents Record of electric power consumption in three and
one phase circuits Non-frequent urgent switching on and switching
off of outgoing lines
Technical dataRated current, In from 16 to 630 A
Surge current, Ikp up to 20 kA
Rated three phase voltage, Un 380 V
Rated frequency, f 50 Hz
Protection rating IP31 – IP65
Dimensions of one section (height × width × depth), mm 600–2,000 × 450–800 × 220–450
Design version
Depending on rated current value and project requirements, the panel can be of on-floor, hinged and built-in versions
Ordering informationWhen placing an order, the Customer should submit the following technical documents depending on the order type:
1. To make an order according to the CUSTOMER’s re-quirements, filled-in questionnaires should be submit-ted . In this case an equipment design work is usually required to be performed upon agreement .
2. To order type items, filled-in questionnaires should be submitted obligatory indicating No . of type diagrams, types of bodies used (intended to be hinged/built-in/installed on the floor, body material, protection rating IP), manufacturers of component parts, other technical parameters .
3. To make an order according to the Customer’s project, project design documents are required: one-line dia-gram or circuit scheme, component parts specifica-tion, drawings . When placing an order for control cabi-nets and automatic equipment, control circuit (functional diagram) is additionally required .
ISDA panel classificationInput for input and registration of electric power
Input with Automat-ic Load Transfer with equipment for automatic load transfer
Distribution for distribution of electrical power, used jointly with input panels
Incoming supply distribution
for input, registration and distribution of electrical power
INCOMING SUPPLY DISTRIBUTION ASSEMBLY
Approval detailsCertificate of conformance to the Customs Union Technical Regulation for complete low voltage cabinets № ТС RU C-RU .АЮ64 .B .01029
116
Switchb
oard eq
uipm
ent
FeaturesALT (ACP) is a panel for automatic load transfer . It is aimed at resuming power supply to users due to automatic switching over to second (redundant) entry if power sup-ply to the first one (main) fails . The system usually auto-matically returns to initial state, when normal power sup-ply at main entry is resumed (priority of the first entry) . The main entry is usually a fixed power mains Un = 380 V, f = 50 Hz . Fixed power mains or diesel-electric engine may serve as a redundant entry . ALT panels are widely used at industrial and civil construction sites, cellular communication stations and others; ALT panels are also used to feed power to sites, where maintenance and re-pair operations take place . The panel automatic equip-ment has an up-to-date element base . The most com-monly used completing unit of the control circuit is fully functional phase control relay; a special controller is used less frequently . These devices control over load-bearing elements: contactors, circuit breakers or automatic mo-tor-driven switches . Equipment made by Hager, АВВ, Schneider Electric, Siemens is used .
ALT (ACP)Automatic load transfer panels ALT (ACP) designed to resume power supply to users due to automatic switching over to second (redundant) entry if power supply to the first (main) one fails
Constant automatic control over electric network at main and back-up entries
Uninterrupted electric power supply to users Visual indication of voltage availability in main
and back-up entries and equipment operation switching over the load either to main or to redundant power sources
Technical dataRated operating voltage, Un 380 V
Rated current, In160–3200 A (up to 160 A for ACP)
Rated frequency, f 50 Hz
Time to switch over from main en-try to redundant one and vice versa 0,5–0,8 sec .
Earth system TN-S; TN-C; TN-C-S
Protection rating IP31 – IP54
Climatic version and location category UHL4 (boreal climate 4)
Design version On-floor/hinged (ACP)
Ordering informationWhen placing an order, the Customer should submit the following technical documents depending on the order type:
1. To make an order according to the CUSTOMER’s re-quirements, filled-in questionnaires should be submit-ted . In this case an equipment design work is usually required to be performed upon agreement .
2. To order type items, filled-in questionnaires should be submitted obligatory indicating No . of type diagrams, types of bodies used (intended to be hinged/built-in/installed on the floor, body material, protection rating IP), manufacturers of component parts, other technical parameters .
3. To make an order according to the Customer’s project, project design documents are required: one-line dia-gram or circuit scheme, component parts specifica-tion, drawings . When placing an order for control cabi-nets and automatic equipment, control circuit (functional diagram) is additionally required .
AUTOMATIC LOAD TRANSFER PANELS (AUTOMATIC CHANGE-OVER PANELS)
Approval detailsCertificate of conformance to the Customs Union Technical Regulation for complete low voltage cabinets № ТС RU C-RU .АЮ64 .B .01029
Advantages ALT cabinet design in two variants – hinged or on-floor (depending on In and Customer’s requirements) – pro-vides free access to control and service elements, and en-sures easy installation and deinstallation .
117
FeaturesCabinets are intended for electrical power automation and distribution in power supply, control and monitoring systems of industrial and domestic electrical heating sys-tems .
The cabinets are used in enterprises of all industries, fuel and energy complex facilities, housing and utilities sector, under production-line conditions, in transport, at con-struction sites, etc .
AEC, CC, PC, ALTC Cabinets for electrical power automation and distribu-tion in power supply, control and monitoring systems of industrial and domestic electrical heating systems
Monitoring of temperature and control of industrial electrical heating systems TEPLOMAG, TEPLOSKAT, TEPLODOR, TEPLOLUXE®
Stand-by supply automatic input Industrial electrical heating systems performance
status indication Protection of equipment against short circuit,
insulation damage (leak current control), overvoltage/undervoltage of power supply
Control and indication of heated objects overheating/underheating
Step connection of load for reduction of starting currents
Technical dataRated operating voltage, Un up to 1,000 V AC or 1,500 V DC
Rated frequency, f 50 Hz
Earth system TN-S; TN-C; TN-C-S
Protection rating IP31 – IP65
Climatic version (UHL1– UHL4) Boreal climate 1 – Boreal climate 4
Design version On-floor/hinged
LOW-VOLTAGE ELECTRICAL CABINETS
Approval detailsCertificate of conformance to the Customs Union Technical Regulation for low-voltage electrical cabinets ТС .RU C-RU .ME67 .B .00110
Completing units– automatic circuit breakers
– knife-switch, fuses
– protective cutout devices
– magnetic contactors
– temperature controllers
– programmable controllers
– switching and display devices
– other electrical equipment
Ordering informationExample: Low-voltage electrical cabinet
CC-TS-3-25-200-00012-0001Cabinet mark CC – control cabinet, PC – power cabinet AEC – automatic equipment cabinet, ALTC – automatic load transfer cabinetElectrical heating system type TS – Teploskat, TM – Teplomag, TD – Teplodor, TL – TeploluxeInput voltage code 1 – up to 230 V, 3 – up to 400 V, 4 – 401...500 V, 5 – 501...700 V, 6 – 701...1000 VRated current of incoming circuit breaker 063 – 63 А 200 – 200 А 080 – 80 А 250 – 250 А 100 – 100 А 320 – 320 А 125 – 125 А 400 – 400 A 160 – 160 А 630 – 630 АType of electronic temperature controller 200 – РТ-200 300 – РТ-300 220 – РТ-220 400 – РТ-400 240 – РТ-240 410 – РТ-410Number project design documents Cabinet sequence number in the project (0001; 0002; etc.)
Swit
chb
oard
eq
uip
men
t
118
Certification
Products
Certificates
Others
Self-regulating electrical heating tapes HTB, HTM, HTA, HTP, BTC, BTX + +
Cable heating sections TOOE, TMOE, TCOE, CMBE, TMTE + +
IRHS-15000 electric heating system (skin-system) + +
Teplomag electric heating system + +
Junction boxes PTB 40*, PTB 60*, PTB 100*, PTB40*-IS, PTB60*-IS +
Constant wattage electrical heating cables LLS, SNF + +
High temperature heating cables BHO, BHC + +
SILARM heat conductive paste +
Electronic temperature controllers PT-240, PT-260, PT-300, PT-400, PT-410, PT-420 +
Measuring transducer unit PTB/IPM +
InWarm Flex Technical insulation + +
Low-voltage electrical cabinets +
The SSTenergomontazh Company has all licenses neces-sary for installation and maintenance of cable heating systems in safe and explosion hazardous zones . Heating cables, finished heating sections made of heating cable, connecting couplings and installation wires, control equipment and accessories – all products produced by SSTenergomontazh have Certificates of conformity, Fire and Health Certificates . Most of products are certified for use in explosion hazardous zones . See the technical data sheets for detailed information .
IEC certificate of conformity IEC Ex for self-regulating tapes IECEx CCVE 12 .0002X
IEC certificate of conformity IEC Ex for IRHS-15000 electric heating system (skin-system) IECEx CCVE 11 .0001X
Certification
Certificate of conformance to the requirements of Cus-toms Union Technical Regulation No . 012/2011 on «Safety of equipment for operation in explosion hazardous envi-ronment» for IRHS-15000 electric heating system (skin-system) with explosion-protection marking of compo-nent parts . No . RU C-RU .ГБ05 .В .00378
Certificate of conformance to the requirements of Cus-toms Union Technical Regulation No . 012/2011 on «Safe-ty of equipment for operation in explosion hazardous environment» for Teplomag electrical heating system with explosion-protection marking of component parts . No . ТС RU С-RU .ГБ04 .В .00249
The SSTenergomontazh certificate of admission to spe-cific work(s) type that effect safety of capital construction facilities . No . П–2 .0192/03
Questionnaires
Questionnaire
2
4
5
678910
111213
15
3
14
1
QUESTIONNAIRE
Customer*
Company
Family name First name Patronymic
Phone
Name
Location*
Available design documentation for heated object Yes No
Installer
Responsible representative
Thermotechnical stage (TTS) (installation drawings and cabinets one-line diagrams)
Freeze protection
Temperature maintenance
Anti-condensate heating
Heating-up Time of heating hours Initial temperature °C
°C, Required pipe temperature*
°C, Minimum ambient temperature
°C, Maximum ambient temperature
°C, Maximum steam temperature in case an object steaming is stipulated
°C, Standard process-oriented temperature* (Product temperature under standard operational conditions)
°C, Maximum process-oriented temperature* (The highest process-oriented temperature the product may occasionally attain)
°C, Maximum allowed product temperature* (The product highest temperature having no adverse effect on the product properties)
°C, Minimum activation temperature* (The lowest temperature, which enables activation of the heating system)
Normal (water, household wastewater)
Open air Buried routing Depth m Soil
Indoors
External Internal
Mineral wool Preinsulated pipes
Foamed rubber Other, heat conductivity coefficient
Onsite Preinsulated pipes
Safe Explosion hazardous
Carbon steel Stainless steel
Plastic
PipelinePipeline name
Pipeline diameter
Heat insulation thickness, mm
Pipe length, m
Quantity of valves, pcs
Quantity of flanges, pcs
Quantity of pipe supports, pcs
Pumped product
Product density, kg/m3
Product heat capacity, J/(kg•°C)
Other, heat conductivity coefficient
W/m•°C
W/m•°C
Corrosive (oil, lube oils, industrial wastes)
Electrotechnical stage (ETS) (electric networks laying diagrams, cable record)
Automation (ACS - automated control systems) (a possibility of centralized control and data transfer to the higher level)
Thermal insulation (TI) (equipment thermal insulation drawings, list of equipment to be installed)
Phone
Site object*
Type of design works*
Purpose of system
Temperature conditions
Steaming*
Environment
Cabling
Heat insulation type*
Heat insulationinstallationZoneclassification
Pipe material*
Parameters of pipeline*
Further information
* – Information field which is mandatory for completing.
Date of filling in*
Pipeline location*
PIPELINE HEATINGDear Messrs!
Please fill in this questionnaire and send it to our address specifying the parameters required for TEPLOMAG electric heating system calculation. We shall send you back a detailed commercial offer .
SSTenergomontazh, LLCProektiruemyj proezd 5274 Bldg . 7, Mytischi, Moscow region,141008, RUSSIATel .: +7 495 627-72-55info@sst-em .ru, www .sst-em .ru
Que
stio
nnai
re
1
2
4
5
6
7
8
9
12
13
14
3
11
10
QUESTIONNAIRE
Customer*
Company
Family name First name Patronymic
Phone
Name
Location*
Available design documentation for heated object
Installer
Responsible representative
Thermotechnical stage (TTS) (installation drawings and cabinets one-line diagrams)
Freeze protection
Temperature maintenance
Anti-condensate heating
Heating-up Time of heating hours Initial temperature °C
°C, Required vessel temperature*
°C, Minimum ambient temperature
°C, Maximum ambient temperature
°C, Maximum steam temperature in case an object steaming is provided
°C, Standard process temperature* (Product temperature under standard operational conditions)
°C, Maximum process temperature* (The highest temperature the vessel may occasionally attain)
°C, Maximum allowed product temperature* (The product highest temperature having no adverse effect on the product properties)
°C, Minimum activation temperature* (The lowest temperature, which enables activation of the heating system)
Open air On the soil
Indoors On supports, their design:
External
Internal
m
m
Distance to heating control point
Distance to power supply point
Mineral wool (mats) Thickness mm
Others, heat-conductivity factor
Safe Explosion hazardous (zone classification)
Carbon steel Stainless steel
Plastic
Horizontal Vertical Fullness coefficient
Diameter
Fittings and hatches:
Type of cover: Flat
Spherical
Conic
Cover height m
mm mmHeight mmWalls thickness
Name*
Density kg/m3
Viscosity at a temperature °Ckg/m•s
Heat capacity J/kg•°C
m3/hDischarge Continuous Cyclic
Other, heat conductivity coefficient
W/m•°C
W/m•°C
Electrotechnical stage (ETS) (electric networks laying diagrams, cable record)
Automation (ACS - automated control systems) (a possibility of centralized control and data transfer to the higher level)
Thermal insulation (TI) (equipment thermal insulation drawings, list of equipment to be installed)
Phone
Site object*
Type of design works*
Purpose of system
Temperature conditions
Steaming
Cabling*
Heat insulation type*
Zoneclassification
Vessel material*
Parameters of the vessel*
Parameters of the product
Further information
* – Information field which is mandatory for completing.
Date of filling in*
Object location*
VESSEL HEATINGDear Messrs!
Please fill in this questionnaire and send it to our address specifying the parameters required for TEPLOMAG electric heating system calculation. We shall send you back a detailed commercial offer .
SSTenergomontazh, LLCProektiruemyj proezd 5274 Bldg . 7, Mytischi, Moscow region,141008, RUSSIATel .: +7 495 627-72-55info@sst-em .ru, www .sst-em .ru
Questionnaire
2
5
6
8
1
3
4
7
1011
12
9
13
QUESTIONNAIRE (INCLUDES ATTACHMENT FOR PACKAGE TRANSFORMER SUBSTATION DESIGN)
Customer*
Company
Family name First name Patronymic
Phone
Name
Location*
Available design documentation for heated object Yes No
Installer
Responsible representative
Thermotechnical stage (TTS) (installation drawings and package transformer substation (PTS) diagrams)
Freeze protection
Temperature maintenance
Open air
Subsea
Buried
In plant conditions Onsite
Laying depth
With pipeline laying depth of over 0.7m from the soil surface, specify the average temperature of the coldest month °С
m Soil
Anti-condensate heating
Heating-up Time of heating hours Initial temperature °C
°C, Required pipeline temperature*
Minimum ambient temperature minus °C, maximum ambient temperature °C
°C, Standard process temperature* (Product temperature under standard operational conditions)
°C, Maximum process temperature* (The highest temperature the vessel may occasionally attain)
°C, Maximum allowed product temperature* (The product highest temperature having no adverse effect on the product properties)
°C, Minimum activation temperature* (The lowest temperature, which enables activation of the heating system)
Mineral wool Foamed polyurethane
Foamed rubber
From one end of heated area Others
From both ends mDistance from power supply point to the beginning of heated area*
Other, heat conductivity coefficient
Safe Explosion hazardous (area classification)
Carbon steel Stainless steel
Plastic
Pipeline
Pipeline name
Pipe outer diameter, mm
Pipe wall thickness, mm
Heat insulation thickness, mm
Pipe length, m
Number of valves, pcs
Number of flanges, pcs
Number of pipe supports, pcs
More detailed further information can be entered in the «Attachment»
Other, heat conductivity coefficient
W/m•°C
W/m•°C
Electrotechnical stage (ETS) (electric networks laying diagrams, cable record)
Automation (ACS – automated control systems) (a possibility of centralized control and data transfer to the higher level)
Thermal insulation (TI) (equipment thermal insulation drawings, list of equipment to be installed)
Phone
Site object*
Type of design works*
Purpose of system
Temperature conditions
Pipeline location*
Heat insulation type*
Supply points location*
Heat insulationinstallation*
Zoneclassification
Pipe material*
Parameters of pipelines*
Further information
* – Information field which is mandatory for completing. Be sure to fill in the «Attachment» !
Date of filling in*
PIPELINE HEATING BY SKIN-EFFECT BASED IRHS-15000 SYSTEMDear Messrs!Please fill in this questionnaire and send it to our address specifying the parameters required for calculation of skin-effect based IRHS-15000 electric heating system. We shall send you back a detailed commercial offer.
SSTenergomontazh, LLCProektiruemyj proezd 5274 Bldg . 7, Mytischi, Moscow region,141008, RUSSIATel .: +7 495 627-72-55info@sst-em .ru, www .sst-em .ru
Que
stio
nnai
re
2
1
3
4
5
6
7
8
9
10
11
12
13
14
15
ATTACHMENT TO THE QUESTIONNAIRE
Customer*
Company
Family name First name Patronymic
Phone
Name
Location*
Available design documentation for heated pipeline Yes No
Installer
Responsible representative
Kiosk type without heat insulation and heating
Kiosk type with heat insulation and heating
Cable
Aerial
On soil
On supports
Others
Phone
Site object*
PTS design
Supply lead
Installation
Indication
Fire extinguisher
Automatic
Others:
Fire fighting system
Natural draft
Forced draft
Air conditioner
Others:
Ventilation system
Yes
No Others:Remote control
Signaling
Control
Monitoring
Others:Telemetry
Horizontal
VerticalOthers:Earthing
Yes
NoOthers:
Energyaccounting
Oil filled
Dry
Transformer type
Relay module
Electronic module
Diesel generator
Power line
Others
Supply voltage
Frequency
Number of phases
V
Hz
Protection type
System’s power supply parameters*
Further information
* – Information field which is mandatory for completing. Be sure to fill in the QUESTIONNAIRE !
Date of filling in*
PIPELINE HEATING BY SKIN-EFFECT BASED IRHS-15000 SYSTEMDear Messrs!Please fill in this questionnaire and send it to our address specifying the parameters required for calculation of skin-effect based IRHS-15000 electric heating system. We shall send you back a detailed commercial offer.
SSTenergomontazh, LLCProektiruemyj proezd 5274 Bldg . 7, Mytischi, Moscow region,141008, RUSSIATel .: +7 495 627-72-55info@sst-em .ru, www .sst-em .ru
Questionnaire
2
3
5
1
4
QUESTIONNAIRE
Customer*
General data*
Control
Auxiliary equipment
Further information
Company
Family name First name Patronymic
Phone
Phone
CLVC name (purpose in brief)
Diagram sequence number (for typified product)
Earthquake intensity as per MSK-64
Seismic safety group according to GOST 30546.1-98
Location of installation
Minimum ambient temperature minus
Protection rating IP
Power cables lead
Power cables cross section
Cables lead from load
mm2
Cables cross section from load
Number of phases
Power supply category
Earth system
Version by installation method
Dimensions of body, mm
Version of front door
Version of back door
Equipment element base
Rated power output of load, maximum
Equipment type EACS (Wago) Temperature controllers
Data transfer protocol
Fiscal metering device
Input amperemeter
Input voltmeter
Ventilation system
Cabinet lighting system
Cabinet heater
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
Data transfer interface
kW Starting current, maximum A
ABB SE Legrand Others
Height × Width × Depth
On-floor Hinged Built-in
TN-S TN-C TN-C-S
Supply voltage V Frequency Hz
mm2
From top From bottom
From top From bottom
Climatic version according to GOST 15150-69
°С, maximum ambient temperature °С
Outdoors Indoors
* – Information field which is mandatory for completing.
Date of filling in*
PRODUCTION OF COMPLETE LOW VOLTAGE CABINETDear Messrs!
Please fill in this questionnaire and send it to our address specifying the parameters required to design and manufacture complete low voltage cabinet (CLVC). We shall send you back a detailed commercial offer.
SSTenergomontazh, LLCProektiruemyj proezd 5274 Bldg . 7, Mytischi, Moscow region,141008, RUSSIATel .: +7 495 627-72-55info@sst-em .ru, www .sst-em .ru
125
Que
stio
nnai
re
126
Industrial heating
systems
SSTenergomontazh, LLCProektiruemyj proezd 5274 Bldg. 7Mytischi, Moscow region,141008, RUSSIATel.: +7 495 627-72-55E-mail: [email protected]