Installation Instructions Decentralized Ventilation System with Heat Recovery Type e go - Please pass on to the User- Contents Page: Concerning these Instructions, Safety Instructions, Technical Data, Disposal 1 Dimension drawings, Installation position, Range of application 2 Delivery components 3 Assembly: Assembly tube 4 Assembly: electrical installation and electrical connection 5 Coding switch settings, Installation of light-emitting diodes in the switch 6 Assembly: Fan insert, inside panel 7 Assembly Outside panel, Closing the inside panel 9 Filter change, Cleaning, Additional and Spare parts 10 Concerning these Instructions Please read these instructions carefully and fully before commencing with assembly work! The general safety instructions and safety symbols with text must be observed! These instructions are to be passed on to the user (tenant, owner, building management etc.) after completion of assembly work. Symbols in these instructions This symbol warns of a risk of injury. This symbol warns of risk of injury from electricity Safety Instructions Caution! Assembly work on the ventiltion unit must only be executed when the power supply has been completely de-energized. The ventilation unit is insulated in accordance with Protecti- on Class II, insulation connection does not apply! Attention! The electrical connection must be carried out by authorized qualified staff in accor- dance with VDE 0100! Attention! This device must not be used by children and persons (filter change/cleaning) who ae not able to operate it properly on account of their physical, sensory or mental condition or their inexpetrience or lack of know-how. Children must be supervised to ensure they do not play with the device. Technical Data Supply voltage: 230 VAC 50 Hz Device voltage: 12 VDC SELV Protection Class: IP 22 Flow rate: 5; 10; 15; 20 m³/h in reverse operation, 45 m³/h in exhaust air mode Disposal Separate the packaging and dispose of accordingly. If you wish to throw away the device, you must dispose of it in accordance with curent legal regulations. Contact your local com- munity center for details. 1

Upload: others

Post on 05-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Installation Instructions Decentralized Ventilation System with Heat Recovery

Type ego

- Please pass on to the User-

Contents Page:

Concerning these Instructions, Safety Instructions, Technical Data, Disposal 1 Dimension drawings, Installation position, Range of application 2 Delivery components 3 Assembly: Assembly tube 4 Assembly: electrical installation and electrical connection 5 Coding switch settings, Installation of light-emitting diodes in the switch 6 Assembly: Fan insert, inside panel 7 Assembly Outside panel, Closing the inside panel 9 Filter change, Cleaning, Additional and Spare parts 10

Concerning these Instructions

• Please read these instructions carefully and fully before commencing with assembly work! The

general safety instructions and safety symbols with text must be observed!

• These instructions are to be passed on to the user (tenant, owner, building management etc.)

after completion of assembly work.

Symbols in these instructions

This symbol warns of a risk of injury.

This symbol warns of risk of injury from electricity

Safety Instructions

Caution! Assembly work on the ventiltion unit must only be executed when the power supply has been completely de-energized. The ventilation unit is insulated in accordance with Protecti-on Class II, insulation connection does not apply!

Attention! The electrical connection must be carried out by authorized qualified staff in accor-dance with VDE 0100!

Attention! This device must not be used by children and persons (filter change/cleaning) who ae not able to operate it properly on account of their physical, sensory or mental condition or their inexpetrience or lack of know-how. Children must be supervised to ensure they do not play with the device.

Technical Data

Supply voltage: 230 VAC 50 Hz Device voltage: 12 VDC SELV Protection Class: IP 22 Flow rate: 5; 10; 15; 20 m³/h in reverse operation, 45 m³/h in exhaust air mode

Disposal

Separate the packaging and dispose of accordingly. If you wish to throw away the device, you must dispose of it in accordance with curent legal regulations. Contact your local com-munity center for details.

1

Page 2: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Dimension drawing (all dimensions in mm)

Installation Position

2

Range of Application

Temperature range of application: - 15°C to + 40°C Can be used at a relative humidity up to 65% in the interior room area. Low formation of condensation during the heating period is possible. If the application limit is exceeded, switch off the device and close the inside panel. Ensure supply of fresh air via window ventilation.

ego

* minimum ** longer lengths possible Dimensions in mm

Minimum distances to wall and surrounding components Two fans operate in the e², always in opposite directions providing supply and exhaust air simultane-ously. Minimum distances to the wall and surrounding components must be observed to ensure u-nobstructed air flow without inad-missible mixing of supply and ex-haust air!

Wall

Window

Inside Outside

237 257

63 300* to 500** 63

217

30 cm 25 cm

30 c

m

Page 3: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Delivery items

Check your delivery for completeness and perfect condition!

3

Assembly tube

ego-insert

Outside panel

+ Screws accessories

Tube DA 160 mm

Plaster cover

Cover

Filter

Inside housing sub-part

Closing element (2x)

Heat exchanger unit with motor

2 pce.s EPP adapter (mounted)

Optional: additional EPP adapter

Cover

Outside panel sub-part

Inside panel with heat exchanger unit and adapter stick

Page 4: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Assembly—Assembly Tube

Prepare wall openings for the as-sembly tube (e.g. via core drill hole, core bit Ø162 mm). If necessary, shorten the tube to the installation length required. Make sure there is a slight projection of the tube on both sides to bridge the plaster thickness (after plaste-ring, the tube must be flush with the plaster). Insert the tube and seal it all-round (Assembly adhesive Order No. 038 733).

Apply inside and outside plaster.

4

inside

inside outsi-

outside

Plaster cover

3 m

m

Prepare the cable for the device connection in the designated section (e.g. J-Y (ST9Y4x2x0,8).Cable length approx. 100 to 120 mm. Use the drilling template!

4.6 cm

3.9

cm

Core drill hole or wall installation tube

Section for device cables

3

Page 5: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Assembly – Electrical Installation and electrical connection

Caution! All installation work on the ventilation device must only be executed when the supply voltage has been completely deactivated and de-energized.

De-energize all connection lines to supply voltage before connecting the ventilation device! (separation from grid with min. 3 mm contact opening, e.g. all-phase separating electric fuse).

Each circuit connected to this ventilation system must be fitted with residual current protection (e.g. RCD switch)!

Electrical connection must be executed by a qualified electrician!

Additional installations and electrical components in this ventilation system are not admissible!

Safety Instructions

5

Triggering can be made via the universal control 5/UNI and the comfort control TAC. The respec-tive installation instructions apply accordingly. Select the position of the switch. Slit the cable chan-nels. Connect the cable to the switch and locate the power pack under the switch e.g. 3x 1.5mm², otherwise a cross-section suffices e.g. J-Y(ST)Y 4 x 2 x 0.8) and the cables to the devices ( e.g. J-Y(ST)Y 4 x 2 x 0.8). Switching and switch are connected in accordan-ce with the connection plan displayed below.

* with power pack 5/NT18 (18 Watt): max. 2 ego With power pack 5/NT60 (60 Watt): max. 5 ego

I III II

0

Important: set the coding switch to the required functions in accordance with the table on p. 4. Devia-ting coding switch settings are inadmis-sible and result in malfunctions!

Series switch 5/W2U Front view

Universal control

grey red black

red blue purple red blue purple

W1 W2

+ 12V

-

TAC (optional)

El. connection ego with control 5/UNI and external power pack

+ - Sx

+ - S1 + - S2

Device 1 Exhaust/Supply other devices*

Junction box

Switch

Power cable or cable to switch

Page 6: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

6

Codieng switch setting programs and volume flow steps

Coding switc setting

Fan type Functional descripti-on

Rockers W 2

Rocker1 OFF

Rocker 1 ON

Rocker 1 OFF

Rocker 1 ON

Rocker 2 OFF

Rocker 2 OFF

Rocker 2 ON

Rocker 2 ON

9 ego OFF, three-step OFF 5m³/h 10 m³/h 20 m³/h Summer ventilati-on

A ego Four-step 5 m³/h 10 m³/h 15 m³/h 20 m³/h Summer ventilati-on

B ego Three-step and exhaust air

5 m³/h 10 m³/h 20 m³/h 45 m³/h (exhaust air)

Summer ventilati-on

C ego OFF, two-step and exhaust air

OFF 5 m³/h 10 m³/h 45 m³/h (exhaust air

Summer ventilati-on

Programs and air flow rates

Attention The light-emitting diode points upwards and is inserted into the circular opening on the underside of the switch provided by LUNOS! Please check the opening for the LED when using conventional series switches!

The filter change display is reset within 3 s via actuating the rocker switch W1 once in all program options.

Installation of light-emitting diodes of control 5/UNI in the switch

LED

gelb

weiß

rot

grau

KNX cable

L1.A

L1.B

L2.A

L2.B

bl rt li

ego Device 1 ego Device 2

LUNOS-KNX-Controller

bl rt li

bl rt li

bl rt li

bl rt li

+ - S1 + - S2 + - S1 + - S2

L1.A

L1.B

L2.A

L2.B

Electrical connection ego (2 devices) with LUNOS-KNX-control

Page 7: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Assembly – Assembly fan insert, inside room panel

7

Drill the fastening bores for the inside room panel using the dril-ling template and insert the do-wels enclosed. Note: Observe the label ‚TOP‘, any deviating installation position is not admissible for flow-related reasons!

Drilling diamater: 6mm

Remove the plaster cover. Shor-ten the EPP adapter to the length of the assembly tube. In the case of tube lengths above 500 mm, additional adapter pieces may be mounted!

Insert the fan unit (inside panel sub-part, heat exchanger unit and EPP adapter) into the assembly tube!

1

2

3

TOP

Device con-nection cable

Drilling template

Position of fastening bores (4x)

Same length

inside Assembly tube

Shorten here

Heat exchanger unit

EPP-Adapter

Plaster cover

Device connecti-on cable

Page 8: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

8

Insert the connection cable through one of the boots of the inside housing sub-part in the section of electrical connecti-on! Fasten the inside housing sub-part to the wall using the screws enclosed!

Connect the ventilation unit! (Connection plan, refer to p 5)

Mount the cover for the electrical con-nection section and insert the closing element on top!! Insert the filter and snap on the cover!

4

5

6

Boot

Connection cable

Screw (4x)

+ - S1 + - S2

Power cable Boot

Filter

Cover

Inside housing sub-part

Cover for con-nection section

Closing ele-ment (2X)

Page 9: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

9

Assembly—outside panel

Closing the inside panel

Using the drilling template, drill the fastening drill holes and in-sert dowels (in accordance with the surface) provided on-site (refer to ‚Assembly of inside room panel‘ Image 1). Place the outside panel sub-part on the EPP adapter located in the tube!

Fasten the outside panel sub-part using the screws enclosed! Place the cover on top!!

The inside panel can be closed, if required, using the magnetic closing elements: place the clo-sing elements with the red side outwards from the inside in front of the fan grille! Apply the cover!

7

8

Rear side outside panel sub-part

EPP Adapter (in the tube)

Insert here! Only vertical position of center bar is ad-

missible

Cover

Screws (4x)

Outside panel sub-partl

Cover

Closing elements inserted in closed status

Location of closing elements

Page 10: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Filter change date planned filter change Filter type used

Please enter the filter changes you have carried out:

Filter change

The filter change display signals a contaminated filter. In connection with the universal control, a LED lights up continuously in red be-neath the switch. Remove the cover. Remove the filter, insert new or cleaned filter (cleaning of the filter can be made e.g. using the dishwasher). Place the cover on. The ventilation vents must not be obstructed or covered. Reset the filter change display by pressing the rocker switch W1 once. Functioning of the filter chan-ge display in connection with the TAC and LUNOS KNX control is included in the respective instructi-ons.

Cleaning

If required, wipe the inside room panel and cover frame with a dry, soft cloth. Filter change and cleaning must not be carried out by children and persons not able to execute such work on account of their physical, sensory or mental condition or their inexperience or lack of know-how.

Additiona/Spare parts

Cover Filter

Filter G3 Type 9/FEGO-3R Pack of 4 Order No.: 039 998 Pollenfilter Type 9/FEGO-P Pack of 4 Order No.: 039 982 EPP Adapter Type 2/AD 160 Order No.: 039 965

I III II

LED lights up beneath the switch

Page 11: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

Notes

Page 12: Installation Instructions Decentralized Ventilation System with …laros.com.au/wp-content/uploads/2016/01/LAROS-LUNOS... · 2017-02-22 · De-energize all connection lines to supply

E 1

68

/ 0

3.1

4

Deutschland

LUNOS Lüftungstechnik Tel.: 0 30 / 36 20 01 - 0 GmbH für Raumluftsysteme Fax: 0 30 / 36 20 01 - 89 Wilhelmstr. 31 E-Mail: [email protected] 13593 Berlin Internet: http://www.lunos.de

Notes