instruction manual tia / eia industrial tia / eia green ... assembly instruction.pdf · instruction...

2
Instruction Manual White/Orange Orange White/Green Green White/Green Green Blue White/Blue Blue White/Blue White/Brown Brown White/Orange Orange White/Brown Brown 1 2 3 6 4 5 7 8 TIA / EIA T568B Yellow Orange White Blue INDUSTRIAL TIA / EIA T568A Fan out all four twisted pairs, following the color coding label and allocate each conductors into proper slots on wiring cap. Trim the ends of conductors. 1 Remove the wiring label before place wiring cap on plug. Place the wiring cap onto plug, use plier to clamp wiring cap until it completely snap-in to effect the connection. Close plug cover, make sure the drain wire is in proper contact with grounding clip on plug. Pull back strain relief boot to cover the plug, fasten supplied cable tie to secure grounding contact. 3 4 6 5 Drain Wire Cable Tie Insert cable into strain relief boot, strip off 1.2 inch of cable jacket, fold back the drain wire. 2 Remove the stopper before installation. Cover Stopper Open shielded cap Cut off cable tie, remove the boot. Using flat screw driver and pry gently on plug cover one end first and the other end subsequently to open it. Unload the cable Cut the end of boot to fit your cable OD. Boot adjustment Cut off cable tie Wiring Label Remove boot 1.2"(30mm)

Upload: vuquynh

Post on 20-Oct-2018

243 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Instruction Manual TIA / EIA INDUSTRIAL TIA / EIA Green ... ASSEMBLY INSTRUCTION.pdf · Instruction Manual White/Orange Orange White/Green Green White/Green Green Blue White/Blue

Instruction ManualWhite/OrangeOrange

White/GreenGreen

White/GreenGreenBlueWhite/Blue

BlueWhite/Blue

White/BrownBrown

White/OrangeOrange

White/BrownBrown

12364578

TIA / EIAT568B

YellowOrangeWhiteBlue

INDUSTRIALTIA / EIAT568A

Fan out all four twisted pairs, following the color coding label and allocate each conductors into proper slots on wiring cap.Trim the ends of conductors.

1

Remove the wiring label before place wiring cap on plug.

Place the wiring cap onto plug, use plier to clamp wiring cap until it completely snap-in to e�ect the connection.

Close plug cover, make sure the drain wire is in proper contact with grounding clip on plug. Pull back strain relief boot to cover the plug, fasten supplied cable tie to secure grounding contact.

3

4

6

5

Drain Wire

Cable Tie

Insert cable into strain relief boot, strip o� 1.2 inch of cable jacket, fold back the drain wire.

2

Remove the stopper before installation. Cover Stopper

Open shielded cap

Cut o� cable tie, remove the boot. Using �at screw driver and pry gently on plug cover one end �rst and the other end subsequently to open it.

Unload the cable

Cut the end of boot to �t your cable OD.Boot adjustment

Cut o� cable tie

Wiring Label

Remove boot

1.2"(30mm)

Page 2: Instruction Manual TIA / EIA INDUSTRIAL TIA / EIA Green ... ASSEMBLY INSTRUCTION.pdf · Instruction Manual White/Orange Orange White/Green Green White/Green Green Blue White/Blue

MontageanleitungWeiß/OrangeOrange

Weiß/GrünGrün

Weiß/GrünGrünBlauWeiß/Blau

BlauWeiß/Blau

Weiß/BraunBraun

Weiß/OrangeOrange

Weiß/BraunBraun

12364578

TIA / EIAT568B

GelbOrangeWeißBlau

INDUSTRIALTIA / EIAT568A

Adern entsprechend dem Farbcode in dieManagementbar einführen und kurz abschneiden.

1

Wiring Label entfernen .

Managementbar im Stecker positionieren und mit einer Zangefest verpressen, bis die Managementbar einrastet.

Steckerklappe schließen.Kabel mit Kabelbinder �xieren. Tülle über den Stecker schieben. Fertig!

3

4

6

5

Kabelbinder

Kabel durch die Hülle schieben. Kabel-mantel auf einer Länge von ca. 30 mmentfernen.

2

Stopper entfernen. Stopper

Steckerklappe ö�nen

Ö�nen des Steckers

Um die Tülle an größere Kabeldurch-messer anzupassen, entsprechend kürzen!

Kabelbinderdurchschneiden

Wiring Label

Tülle nachhinten schieben

1.2"(30mm)