iry-pc water_uf+edi
TRANSCRIPT
![Page 1: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/1.jpg)
IRY-PC ENGINEERING PVT. LTD.Enhance Efficiency
![Page 2: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/2.jpg)
Company Mission and Vision
IRY-PC Engineering Pvt. Ltd. a group company of IRY engineering Pvt Ltd isone stop solution provider for all the Engineering manufacturing needs ofcustomers.
Our Mission is to exceed the expectations of the customer with ourtechnological skills & understanding of processes, innovative designs, highinternational quality manufacturing standards and delivering high qualityservices ensuring Long term relationship.
Our Vision is to be the leader in our Chosen Field of Operations throughregular developments, quality services and by ensuring total customersatisfaction.
![Page 3: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/3.jpg)
An IRY Group Enterprise with diversified interests in
High End Electro‐Mechanical Engineering Solutions for General & Automobile Industries
Commercial Building Services
Water Engineering
IRY - PC
![Page 4: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/4.jpg)
The issues surrounding PRODUCTIVITY are complex, urgent and interrelated:
• Output Vs Input Factors• Design & Ergonomics• Environmental issues & Water scarcity• Aging infrastructure• Energy consumption
We have the size, scope and focus to address them all.
Enhance your Efficiency: Our Tagline and Purpose
![Page 5: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/5.jpg)
1
2
3 4
5
67
8
9
1. Raw Water Source2. Transport Water3. Treatment and Purification4. Transport Water5. Home/ Industrial use6. Transport Water7. Waste Water/ Industrial
Influent Treatment8. Recycle & Reuse9. Natural Body Discharge
![Page 6: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/6.jpg)
Area of Operations
• Municipal Water & Sewage Treatment• Sewage Collection Network• Water Distribution Network• Civil Hydraulics & Structural Design• Industrial Water Treatment• High Purity Water Generation & Distribution System
( Pharma & Semiconductor)• Wastewater /Effluent Treatment• Electrical , Instrumentations & Automation Controls• HVAC• Firefighting Systems• Utility Piping• Process Piping
FOR
DETAILED DESIGN &
EXECUTION
As a
CONSULTANT. EXECUTING
AGENCY
&
SELECT COMPONENT
SUPPLIES
![Page 7: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/7.jpg)
ULTRA FILTRATION
![Page 8: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/8.jpg)
Affiliation
QUA Technologies
![Page 9: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/9.jpg)
QUA Water Technologies
Ultrafiltration: Q-SEPFractional Electro deionization: FEDI
![Page 10: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/10.jpg)
Advanced Membrane Products
![Page 11: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/11.jpg)
WHY QUA?
![Page 12: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/12.jpg)
Head quartered in The USA
Manufacturer of advanced membrane products for water, wastewater and water reuse applications
Extensive R&D activities for over a decade, resulted in a range of cutting edge membrane products
![Page 13: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/13.jpg)
What is Ultrafiltration??
![Page 14: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/14.jpg)
![Page 15: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/15.jpg)
• Purification of surface water, groundwater and spring water to make drinking water and process water
• Treatment of waste water• Pretreatment in sea water desalination plants in
combination with reverse osmosis or thermal treatment
• Water for industrial use to close water cycles
Uses of Ultrafiltration
![Page 16: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/16.jpg)
• Removal of germs, bacteria, viruses and all types of suspended solids
• The quality of the treated water remains the same regardless of the degree of contamination of the original water
• Simple and safe to operate and manage
Advantages of Ultrafiltration
![Page 17: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/17.jpg)
Poly Ether Sulphone (PES)Inside-Out Flow
![Page 18: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/18.jpg)
![Page 19: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/19.jpg)
• NSF (National Sanitation Federation)1. For Drinking water2. For 6.2 log Bacteria rejection at 150 LMH Flux
Certifications
![Page 20: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/20.jpg)
• Flux(LMH)- Filtrate flow rate through membrane• Flux X Area = Flow per membrane• Because of the patented technology, we offer
higher flux rates than our competition
Flux
![Page 21: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/21.jpg)
Operational ParametersFiltrate flux range 50 to 150 l/m h (30 to 90 gfd)Maximum feed pressure 5.0 bar (70 psi)Trans-membrane pressure 0.3 to 1.4 bar (5 to 20 psi)pH range 2 to 12Typical instantaneous chlorine tolerance 100 to 200 ppmMaximum operating temperature 45°C (113°F)Typical feed turbidity 0.8 mm ID: 25 NTU
1.2 mm ID: 50 NTUBackwash flux range 150 to 300 l/m h (90 to 180 gfd)Backwash feed pressure 0.7 to 2.1 bar (10 to 30 psi)
Backwash frequency & duration Every 15 - 45 minutes for 30 - 60 seconds
![Page 22: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/22.jpg)
Efficient backwash
More resistant to low and high pH
Ability to feed & backwash from top and bottom
Higher packing density
No dedicated CIP required
Lower cost module
Advantages PES I/O over PVDF O/I
![Page 23: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/23.jpg)
![Page 24: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/24.jpg)
2010 -
Ultra Filtration
2006 - 2009
1995 - 2005
RO FEDITM
Pretreatment 2 Pass RO EDI
Pretreatment RO Mixed Bed
up to 1980
Pretreatment Cation/Anion Mixed Bed
High purity water production over the years
![Page 25: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/25.jpg)
Introduction to EDI
![Page 26: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/26.jpg)
Advantages of EDI over Mixed Bed Technology
•Eliminates harsh treatment chemicalsGreen TechnologyBulk chemical storage not requiredSafety Considerations
•Eliminates need for regenerationContinuous operation; improved qualitySimple to operateRegeneration system not required
•Lower operating cost
•Modular equipment, scalable
•Smaller footprint, could be made mobile
![Page 27: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/27.jpg)
MO
hm.c
m
Time
Continuous, Simple Operation
• Eliminates batch processing• Provides consistent product water quality on a continuous
basis• Operator Intervention is not required
Mixed-bed Batch Processing EDI Continuous Processing
18.2
MO
hm.c
m
Time
EDI delivers 16 to 18 Mohm.cm watercontinuously
• Reduced installation and commissioning time• No complex operating procedures
Advantages of EDI over Mixed Bed Technology
![Page 28: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/28.jpg)
The Next Generation of EDI
• Fractional ElectrodeionizationProcess, May 24, 2005
US Patent #6896814 B2
• Method of preparing ion exchange media, Jan 16, 2007.
US Patent # 7163964 B2
FEDI – Fractional Electrodeionization
![Page 29: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/29.jpg)
THANK YOU
![Page 30: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/30.jpg)
IRY-PC Engineering Pvt. Ltd.1545, Sector 17C, Gurgaon
Haryana, India
Tel No.:+91 124 3354234
M. No: +91 9810839650Email: [email protected]: www.iryengineering.com
OFFICES
![Page 31: IRY-PC Water_UF+EDI](https://reader035.vdocuments.net/reader035/viewer/2022062413/588b1b741a28ab78398b54a3/html5/thumbnails/31.jpg)