Ventileksempler .................................................................. 2

Blandeventilen .................................................................... 3

Løsningsforslag .................................................................... 4

Dimensjonering ................................................................... 5

Prinsippskisser ...................................................................... 6

Dusjeksempler ..................................................................... 8

Teknisk ................................................................................. 9

Problemløsning ................................................................. 11

Notater ............................................................................... 12

Ventilprogram Innhold

Blandeventil JRGUMAT® / bronse• Leveres med kuplinger• Leveres med isolasjonskappe• DN 15 - DN 80• Nøyaktighet +/- 1°C ved riktig dimensjonering• Kan leveres kuplinger til andre typer rør og fittings• Kan monteres i alle retninger• Den mest driftssikre ventilen på markedet

Skråseteventil JRG Legiostop® / bronse m/tilbakeslagsventil• Syrefast spindel• Ingen vannlommer• Gjenge i spindel sitter utenfor vått område, den vil derfor ikke sette seg fast• DN 15 - DN 50• Leveres med utvendig gjenge, innvendig gjenge, MT kupling. Andre kuplingstyper på forespørsel

Skråseteventil JRG Legiostop® / bronse• Syrefast spindel• Ingen vannlommer• Gjenge i spindel sitter utenfor vått område, den vil derfor ikke sette seg fast• Kan gjøres om til tilbakeslagsventil• DN 15 - DN 50• Leveres med utvendig gjenge, innvendig gjenge, MT kupling. Andre kuplingstyper på forespørsel

Termisk ventil JRGUTHERM® / bronse• Brukes til å styre sirkulasjonen• Sørger for riktig sirkulasjonstemperatur• DN 15 . DN 20• Innstilles ca 5º over blandeventilens temperatur

Reduksjonsventil JRGURED® / bronse• Kan brukes for å redusere vanntrykket i alle installasjoner• type 1300 for vann inntil 30ºC• type 1310 for vann fra 30 til 70ºC

Ventilprogram Ventileksempel

3400

5221

5266

6320

2

Reguleringsmuffe, JRG / bronse• Nåleventil som brukes til å styre vannmengden i sirkulasjonsledningen• DN 15 . DN 20

6310

1300

1310

Ventilprogram Blandeventilen

3

Forhåndsinnstilt Mulig innstilling Temperaturendring temperatur ºC temperatur °C ved 1 omdreining GN ½-1 GN 1½-2 DN 15-25 DN 32-50 DN 65-80 25 20-30 40 30-45 48 36-53 ca.6K ca.4K ca.2K 55 45-65

JRGUMAT® blandeventiler leveres i støpt bronse og bør monteres i alle anlegg der det kreves jevn tem-peratur og høyeste krav til funksjon og levetid.

• Økonomisk

• Miljøvennlig

• Høy kvalitet

• Lang levetid

JRGUMAT® har forhåndsinnstilt temperatur fra fabrikken. Innstilte temperatur står på justeringsskiven på toppen av ventilen (1). Nedenforstående tabell viser temperatur-endringer ved en omdreining av justeringsskruen.

A TermostatB Ventilskive bronseC Stang syrefast stål

1 Ventilhus bronse2 Reguleringssylinder3 Justeringsskrue messing4 Kaldtvannssete syrefast stål5 Varmtvannssete bronse6 Sirkulasjonshylse kunststoff, tilkobles med kupling kat.nr. 8201

ACB

2

16

5 4

3

1 2

1

2

Ventilprogram Løsningsforslag

4

Alternativer ved 1” JRGUMAT® 3400Antall Beskrivelse NRF.nr.1 Blandeventil 1” m/kupling 25ºC (20-30ºC) 445 11 13 Blandeventil 1” m/kupling 40ºC (30-45ºC) 445 11 16 Blandeventil 1” m/kupling 55ºC (45-65ºC) 445 11 19

Skråseteventil m/tilb.sl.v. JRG Legiostop® Antall Beskrivelse NRF.nr.2 Skråseteventil m/tilb.sl.v. DN 25 1” 554 51 31

Deler for sirkulasjonskoblingAntall Beskrivelse NRF.nr.1 Reguleringsventil ½” 445 12 53 3 Kupling ½” u/avst. f/6320 445 12 632 Skråsetventil m/tilb.sl.v. DN 15 ½” 554 51 28

Alternativer ved 1¼” JRGUMAT® 3400Antall Beskrivelse NRF.nr.1 Blandeventil 1¼” m/kupling 25ºC (20-30ºC) 445 11 23 Blandeventil 1¼” m/kupling 40ºC (30-45ºC) 445 11 26 Blandeventil 1¼” m/kupling 55ºC (45-65ºC) 445 11 29

Skråseteventil m/tilb.sl.v. JRG Legiostop®

Antall Beskrivelse NRF.nr.2 Skråseteventil m/tilb.sl.v. DN 32 1¼” 554 51 32

Deler for sirkulasjonskoblingAntall Beskrivelse NRF.nr.1 Reguleringsventil ½” 445 12 53 3 Kupling ½” u/avst. f/6320 445 12 632 Skråseteventil m/tilb.sl.v. DN 15 ½” 554 51 28

Alternativer ved 1½” JRGUMAT® 3400Antall Beskrivelse NRF.nr.1 Blandeventil 1½” m/kupling 25ºC (20-30ºC) 445 11 33 Blandeventil 1½” m/kupling 40ºC (30-45ºC) 445 11 36 Blandeventil 1½” m/kupling 55ºC (45-65ºC) 445 11 39

Skråseteventil m/tilb.sl.v. JRG Legiostop®

Antall Beskrivelse NRF.nr.2 Skråseteventil m/tilb.sl.v. DN 40 1½” 554 51 33

Deler for sirkulasjonskoblingAntall Beskrivelse NRF.nr.1 Reguleringsventil ½” 445 12 53 3 Kupling ½” u/avst. f/6320 445 12 632 Skråseteventil m/tilb.sl.v. DN 15 ½” 554 51 28

Anbefalt blandeventil for:Nød-/øyedusj; forhåndsinnstilt 25ºCDusjanlegg; forhåndsinnstilt 40ºCForbruksvann; forhåndsinnstilt 55ºC

Anbefalt blandeventil for:Nød-/øyedusj; forhåndsinnstilt 25ºCDusjanlegg; forhåndsinnstilt 40ºCForbruksvann; forhåndsinnstilt 55ºC

Anbefalt blandeventil for:Nød-/øyedusj; forhåndsinnstilt 25ºCDusjanlegg; forhåndsinnstilt 40ºCForbruksvann; forhåndsinnstilt 55ºC

Tryk

ktap

Avv

ikst

ole

ran

se

Avv

ikst

ole

ran

se +

/- 1

Vannmengde

Tabell for JRGUMAT® - blandeventilene 3400, 3408, 3410 og 3412

Ventilprogram Dimensjonering

Anbefalt vannmengde på JRGUMAT® 3100/3400ved 4-5 bars trykk på varmt og kaldt vann

½” Blandeventil JRGUMAT® DN15 5 - 30 liter/min. ¾” Blandeventil JRGUMAT® DN20 8 - 55 liter/min. 1” Blandeventil JRGUMAT® DN25 15 - 90 liter/min. 1¼” Blandeventil JRGUMAT® DN32 35 - 180 liter/min. 1½” Blandeventil JRGUMAT® DN40 50 - 250 liter/min. 2” Blandeventil JRGUMAT® DN50 70 - 320 liter/min.

5

Beregning av tappemengde og dimensjonEksempel Dusjanlegg - 40 stk dusjer forbruker 8 liter/dusj/minutt (forblandet vann deles inn i soner). - 10 dusjer i hver sone. Det for å få stabilt temperert vann - 10 stk dusjer x 8 liter/min = 80 l/min - 80 l/min på beregningstabell viser 1¼" JRGUMAT ventil

NB! Monter blandeventilen så nærme dusjsonen som mulig for å få kortest ventetid frem til dusjene.

Viktige punkter i anlegg uten sirkulasjon:• Ved trykkforskjell mellom KV og VV større enn 0,5 bar skal det brukes reduksjonsventil.• JRG Legiostop tilbakeslagsventil skal benyttes.• JRGUMAT blandeventil skal alltid monteres minimum en meter fra varmtvanskilde.

Viktige punkter i anlegg med sirkulasjon:• Stabil temperatur på hele strekket gir kort responstid • Ventiler justeres slik at 20% av sirkulasjonen er via varmtvannskilde, energiøkonomisk.• JRG 6320 reguleringsventil sikrer korrekt temperatur på sirkulasjonsledningen.

Ventilprogram Prinsippskisser

6

ill. 1

ill. 2

Ventilprogram Prinsippskisser

Bypass for desinfeksjon

Termisk desinfeksjon:• For å kjøre hettvann gjennom JRGUMAT®, stenges ventil nr.1 og ventil nr. 2 åpnes. Da tvinges hettvann inn på kald side av blandeventilen, slik at både ventiler og rørstrekk desinfeseres. • Etter fullført desinfeksjon (oppnådd 70ºC i 5min. ved tappested), stenges ventil nr. 2 og ventil nr. 1 åpnes.

Normaldrift:Ventil nr. 1: åpenVentil nr. 2: stengtVentil nr. 3: åpenVentil nr. 4: stengt

Desinfeksjon:Ventil nr. 1: stengtVentil nr. 2: åpenVentil nr. 3: stengtVentil nr. 4: åpen

NB!7

ill. 3

Ventilprogram Dusjeksempel

8

Anlegg med forblandet/temperert vann hvor det også skal benyttes dusjer uten blande-batteri (kretsen på venstre side).

Termisk desinfeksjon krever tilleggsinstallasjon, se ill.3 foregående side. Et anlegg som skissert over trenger denne tilleggsinstallasjonen for begge kretser!

ill. 5

ill. 4

Ventilprogram Teknisk

9

NRF Kat.nr. GN DN d2 d3 h1 h2 h3 l l1 l2 ºC445 11 03 3400.920 ¾ 20 G 1 ¼ G½ 32 49 40 100 40 60 25445 11 06 3400.922 ¾ 20 G 1 ¼ G½ 32 49 40 100 40 60 40445 11 09 3400.926 ¾ 20 G 1 ¼ G½ 32 49 40 100 40 60 55445 11 13 3400.930 1 25 G 1 ½ G¾ 36 51 43 110 43 67 25445 11 16 3400.932 1 25 G 1 ½ G¾ 36 51 43 110 43 67 40445 11 19 3400.936 1 25 G 1 ½ G¾ 36 51 43 110 43 67 55445 11 23 3400.940 1¼ 32 G2 G¾ 41 75 52 78 8 78 25445 11 26 3400.942 1¼ 32 G2 G¾ 41 75 52 78 8 78 40445 11 29 3400.946 1¼ 32 G2 G¾ 41 75 52 78 8 78 55445 11 33 3400.950 1½ 40 G 2 ¼ G ¾ 50 77 58 150 58 92 25445 11 36 3400.952 1½ 40 G 2 ¼ G ¾ 50 77 58 150 58 92 40445 11 39 3400.956 1½ 40 G 2 ¼ G ¾ 50 77 58 150 58 92 55445 11 43 3400.960 2 50 G 2¾ G ¾ 60 85 70 180 70 110 25445 11 46 3400.960 2 50 G 2¾ G ¾ 60 85 70 180 70 110 40445 11 49 3400.960 2 50 G 2¾ G ¾ 60 85 70 180 70 110 55

NRF Kat.nr. GN DN d1 d2 d3 d4 h l1 l2 Z1 Z2 554 51 01 5221.240 ½ 15 Rp ½ G ½ 53 86.5 65 45.5 10 27 554 51 02 5221.320 ¾ 20 Rp ¾ G ¾ Rp ¼ 53 104,5 75 56 12 33 554 51 03 5221.400 1 25 Rp 1 G 1 Rp ¼ 60 116,5 90 59 14,5 39,5554 51 04 5221.480 1¼ 32 Rp 1¼ G 1¼ Rp ¼ 70 130 110 58,5 18,5 51,5554 51 05 5221.560 1 ½ 40 Rp 1½ G 1½ Rp ¼ 90 147,5 120 67 19,5 60,5554 51 06 5221.640 2 50 Rp 2 G 2 Rp ¼ 90 169 150 67 23 77

NRF Kat.nr. GN DN d1 d2 d3 d4 h L1 L2 Z Z1 Z2 554 51 28 5266.240 ½ 15 Rp½ G ½ Rp¼ 53 86,5 65 45,5 37 10 27554 51 29 5266.320 ¾ 20 Rp¾ G¾ Rp ¼ 53 104.5 75 56 45 12 33 554 51 31 5266.400 1 25 Rp1 G1 Rp ¼ 60 116.5 90 59 54 14,5 39,5 554 51 32 5266.480 1¼ 32 Rp1¼ G1¼ Rp ¼ 70 130 110 58.5 70 18.5 51,5 554 51 33 5266.560 1½ 40 Rp1½ G1½ Rp ¼ 90 147.5 120 67 80 19.5 60,5 554 51 34 5266.640 2 50 Rp2 G2 Rp ¼ 90 169 150 67 100 23 77

Skråseteventil m/tilbakeslagsventil

Skråseteventil

Blandeventil 3400

NRF Kat.nr. GN DN d1 h l 445 12 53 6320.914 ½ 15 G ¾ 64 60 445 12 54 6320.924 ¾ 20 G1 64 60

Reguleringsventil

NRF Kat.nr. GN DN d1 d2 h l z 554 50 42 6310.240 ½ 15 Rp ½ 32 50 54 14 8 6310.320 ¾ 20 Rp¾ 36 61 64 17 12

Reguleringsmuffe

Ventilprogram Teknisk

10

NRF Kat.nr. GN DN d d1 h h1 bar 8107.081 ¼ 8 40 R ¼ 38 12 0-12

NRF Kat.nr. GN DN d1 d2 l1 l2 445 12 63 8201.240 R 1/2" G 3/4" 25 6

NRF Kat.nr. GN DN d1 d2 d3 h1 h2 h3 l l1 l2 ºC445 11 53 3410.605 65 65 G 1 ½ 185 82 121 145 290 112 4 40445 11 56 3410.608 65 65 G 1 ½ 185 82 121 145 290 112 4 55445 11 59 3410.805 80 80 G2 200 92 127 155 310 124 8 40445 11 63 3410.808 80 80 G2 200 92 127 155 310 124 8 55

NRF Kat.nr. GN DN l d1 d2 d3 O554 49 84 1650.065 65 240 185 G1/2 554 49 86 1650.080 80 260 200 G1/2

NRF Kat.nr. GN DN d l1 l2 d1 8349.080 ¼ 36 16 47 ?

NRF Kat.nr. GN DN d1 d2 h445 12 03 09 294 04 38 27 1,5 445 12 06 09 294 05 44 35 1,5 445 12 09 09 294 09 56 42 1,5 445 12 13 09 294 07 62,5 50 1,5 445 12 16 09 294 10 78 65 1,5

Kuplingspakning

Kupling

Manometer

Termometer

Tilbakeslagsventil

Blandeventil

NRF Kat.nr. t max °C DN d1 d2 d3 d4 l1 l2 z h1 h2 563 22 04 1300.240 30 15 R ½ G ¾ Rp ⅛ 52 148 34 40 33,5 78,5 563 22 06 1300.320 30 20 R ¾ G 1 Rp ⅛ 58 159 37 42,5 42 85,5 563 22 08 1300.400 30 25 R 1 G 1¼ Rp ¼ 70 184 42 50 51,5 110 563 22 11 1300.480 30 32 R 1¼ G 1½ Rp ¼ 77 212 46 60 64 120,5 563 22 13 1300.560 30 40 R 1½ G 1¾ Rp ¼ 93,5 241 48 72,5 80 157 563 22 15 1300.640 30 50 R 2 G2 ⅜ Rp ¼ 103 289 57 87,5 98 172 1310.240 70 15 R 2½ G¾ Rp ⅛ 52 148 34 40 28,5 78,5 1310.320 70 20 R ¾ G 1 Rp ⅛ 58 159 37 42,5 35,5 85,5 1310.400 70 25 R 1 G 1¼ Rp ¼ 70 184 42 50 51,5 110 1310.480 70 32 R 1¼ G 1½ Rp ¼ 77 212 46 60 64 120,5 1310.560 70 40 R 1½ G 1¾ Rp ¼ 93,5 241 48 72,5 80 157 1310.640 70 50 R 2 G2 ⅜ Rp ¼ 103 289 57 87,5 98 172

Reduksjonsventil

Ventilprogram Problemløsing

11

NOTAT

12

Et ventilhus med mulighet for tre ventiltyper:(1) Tilbakeslagsventil,(2) Skråseteventil og(3) Skråseteventil med tilbakeslagssikring.

En installert ventil kan gjøresom til en av de andre typene. (1)

(2)(3)

Før installasjon avdesinfeksjons løsning

Stadig økende problem med legionella infisert tap-pevann, har satt søkelyset på metoder for fjærning av infeksjonen.

Det er i middlertid en del data som må være på plass før metode velges.

MetoderEt infisert anlegg må desinfiseres og det kan gjøres på flere måter.

Fysisk gjennom:• Termisk desinfeksjon• Membranfiltrering• UV-desinfeksjon m.m.

Kjemisk desinfeksjon:• Klorin• Ozon• Diapharagmalyse etc.

Før valg av metode er det en del som må kartleg-ges. Ikke bare kvaliteten på vannet, men type installasjon, materiale i rørledninger, kuplinger,og type/tykkelse på eventuell isolasjon.

I tillegg må det tas hensyn til i hvilket miljø anleg-get brukes, for eksempel gamlehjem, barnehage, bolig eller idrettshall.

Felles for alle desinfeksjonsmetoder er:• Alle koster penger• Ingen metode kan garantere 100% bakteriefritt anlegg• Medfører ekstra belastning på anlegget.

Punkter som bør kartlegges:• Annleggets layoyt (finnes f.eks. blindrør?)• Sirkulasjonssystem• Rørdimmensjoner• Rørmateriale• Koblinger/kuplinger• Type isolasjonsmateriale/tykkelse• Varmtvannskilde og kapasitet• Vannkvalitet (kloret?)• Bruksmønster

Sjekk også• Temperatur varmt og kaldt vann• plassering og tilstand på varmtvanskilde• Tilstand/vedlikehold av ventiler, koblinger og filtere• Kapasitet og justeringsmuligheter på sirkulasjonspumpe

Forebyggende tiltak• Tilpasse varmtvannskilde• Fjærning av blindrør• Justere rørdimmensjoner• Tilpasse isolasjonstykkelsen på varmt/kaldtvanns rørene• Vurdere separate varmekilder for "fjerntliggende" tappesteder

Vurdere metodeTermisk desinfeksjonDet må først tas stilling til om desinfeksjon må gjø-res kontinuerlig eller i henhold til 3-liter regelen. Uansett må rørene gjennomspyles godt med varmt vann underprosessen. Om det fremdeles finnes blindrør, eller det er fjerntliggende tappesteder, er muligheten ny infisering stor!

Andre ting som må tas i betraktning

Instalasjonsmateriale:• Galvaniserte rør max 60°C (rustfare)• Tilstand og kapasitet på pakninger og annet tetningsmateriale• Ventiler og kuplingers kapasitet

Anleggets layout• Ingen rør med stillestående vann• Rørledninger må ha ekspansjonsmulighet• Mulighet for kabel gjennomføringer i vegg• Varmt og kaldtvannsledninger skal være isolert

Sirkulasjon• Valg av rett kapasitet på sirkulasjonspumpe• Kontinuerlig drift av sirkulasjonspumpe

Varmtvannskilde• Rett type og kapasitet av kjent merke• Kapasitetsvalg må dekke behov ved kjøring av desinfeksjon

Temperaturer ved normal bruk• Temperatur ut fra varmtvannskilde >60°C• Til sirkulasjonstank >50°• Sirkulasjonstemperatur ut/inn for mindre anlegg 1 - 3K, større anlegg 3 - 5K• Varmtvannskilden skal kunne dekke 1times tapping med temperatur >60°C pr dag.

Temperatur ved termisk desinfeksjon• Hele anlegget, tank, rørledninger og sirkulasjonsledninger >70°C• Alle tappepunkt må være åpne i minimum 3 minutter ved >70°C• OBS! Stor skoldingsfare ved desinfeksjon av anlegg

Nye anlegg dimmensjoneres selvfølgelig med tanke på desinfeksjonsmetode, det bør dog legges vekt på hvilket miljø anlegget skal brukes i!

Armaturjonsson ASPostboks 39 Økern - 0508 OSLO

Ulvenveien 87 - 0581 OSLOTelefon 22 63 17 00 - [email protected] - www.armaturjonsson.no

Armaturjonsson har vært på markedet siden 1970 og har de siste 15 årene etablert seg som en av de ledende innen rørsystemer for tappevann og varme innendørs. I tillegg har vi et bredt program av proffarmatur som servant- dusj- og toalettarmatur til offentlige bygg. Vår tredje produktgruppe, installasjonsmateriell, består av nødvendige detaljer for å gjøre enhver montasje på en rask og effektiv måte.

Bedriften er sertifisert i henhold til ISO9001 og miljøstandarden ISO14001. Armaturjonsson har alltid lagt betydelig vekt på kvalitet og utvikling. Det er et klart mål for oss å holde en lederposisjon i markedet. Armaturjonsson skal ikke bare være en stor leverandør, men også en støttespiller for norsk rørleggerbransje.

Det betyr at vi både skal tilby det beste av komponenter og systemer, og de beste rådgivere som bransjen kan oppdrive!