Laboratory Impex Systems (LIS)

• Specialize in the design and manufacture  and supply of health physics, radiation protection and process instrumentation / systems 

– On‐line monitoring systems– Stand alone stations (aerosols, liquid, various gases, dose rate)– Installed building / plant / site / regional networks– Stack sampling and stack flow measurement

• Business Areas: Nuclear, DOE, Universities, Medical Isotope Production

• Established in 1976

Continuous Monitoring Stations

CMS 2 SmartCAM

Area Gamma Monitor Alpha/Beta in Air Monitor

Some More News

• SmartCAM AB+ passes seismic testing February 2011

• The Testing was carried out at the highly regarded Earthquake Engineering Laboratory at Bristol University.

• Used a tri‐axial vibratory shaker table testing, in accordance with IEEE Std 344‐2004, IEEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations.  Testing was carried out in three mutually perpendicular test axes.

• In accordance with IEEE Std 344‐2004, Para 8.1.5.2

• SMARTCAM AB+ continued to monitor and scan radiation particles  without needing any manual intervention in between testing. 

CMS‐GAMMA Area Monitor

• Backlit LCD with text and graphics• One or Two Detectors• GM Detectors can be 1,000 meters away• Can use UDI – Universal Detector Interface• Variety of Detector Types and Ranges• Battery Back up• RS‐485 or Ethernet communications• Relays and two analog outputs• Stainless Steel Construction• Data accessible via standard Web browser

Typical CMS‐2 Installations

• RJ‐45 Network Connection

• Hardwired AC Power cable

• Detector Cabling 

• Easily interpreted lights

• Easy to read display

• Bar graph for % Alarm

GM Detector Ranges

• Standard GM Detectors– GDI RANGE (Integrated Electronics, No UDI 

Required)– GDI‐1304  0.01 rem/h – 1,000 rem/h – GDI‐1314  1 mrem/h – 300 rem/h – GDI‐1324  0.01 mrem/h – 10 rem/h– GDI‐1202  0.01 mrem/h – 4 rem/h– GDI‐1301  0.01 rad/h – 1,000 rad/h– GDI‐1313  0.001 rad/h – 300 rad/h– GDI‐1321  0.3 mrad/h – 10 rad/h

• Other Detectors and Ranges Available!• UDI used for other detector types

Ion Chamber

• ICI‐1 Ion Chamber Interface– Current to TTL frequency converter

• ICD‐1 Ion Chamber– Pressurized Chamber

– 5 mR/h to 5,000 R/h

• 137Cs live‐zero source– 4 µCi or 148 kBq 

• <10 m cable length 

CMS‐Neutron

• CMS‐2 with Ludlum Prescilla Neutron Detector

• Requires UDI

• RJ‐45 Network Connection

• Hardwired AC Power

• Detector Cabling

Hot Cell Monitor HC833

• Simple, panel mount area monitor

• Many different detectors

– Up to 1,000 R/h

• Analog, log scale

• Simple Alarms 

• Relay Outputs

• Stainless steel housing

Rack‐mount Monitoring Systems

• 19” rack mount

• EuroNIM standard

• Complete dose rate or particulate monitoring solution

• Network using RS‐485 or Ethernet

• Very similar to CMS‐1 monitors 

• Key switch and password protected

• Simple LCD text display

• Remote light panels and audible annunciation available

Gas Detector Options

Radioiodine Noble Gas Positrons

Noble Gas and Radioiodine

• Standard Skids• Particulate detector or pre‐filter• 2‐inches of lead shielding• 4π lead shield arrangement• Electronics can mount on skid or 

remotely• RS‐485 or Ethernet• Interface to 9205EMS Data 

Management System• Various types of vacuum pumps 

available

Alarm and Data Management System –9205EMS

• 9205  – Generic Network Software Package• First supplied 1990  with now over 150 installations 

worldwide.• Supports multiple communications protocols• Logs Data (Stack Concentration, Stack Flow, Dose 

Rates)• Real Time Display of Measured Values• Generates and Logs Alarms• Accumulates Stack Discharge (Daily, Weekly, 

Monthly, Annual)• Database of results (History)• Generates Automated Reports in Word format

Stack Sampling Systems

• Shrouded probes

• Meet ANSI N13.1‐1999

• Licensed by Texas A&M

• NQA‐1 Quality Assurance

• Seismic analysis performed

• Design capability

• Gas sampling probes

• Various mounting flanges used

• Stainless steel sample lines and fittings

• Appropriate sample treatment

Installation and Service Support

• Experienced Team of Service and Installation Engineers

• All Classified Workers and RPS Trained

• Safety Passport Holders

• Service Contracts and Tailored Training Courses Available

• New Service Person in Oak Ridge office