Page 1: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser Safety Training

Prof Tony Kent

University Of Nottingham4th. October 2007.

Page 2: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Management of health and safety is based on principles of risk assessment:

Hazard – the potential of a process, material, device etc. to do harm. The hazard is often quantified with regard to the severity of the damage/harm that could occur in a worst-case situation.

Risk – the likelihood that the potential harm would be realized in practice.

The aim is to develop a safe system of work that minimises risk.

This general approach to health and safety is no different for lasers.

Page 3: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser hazards

Compare with looking directly at the sun:

Solar radiation flux density at the surface of the earth ~ 1 kW/m2.

If one were silly enough to stare at the sun, the pupil would contract to about 1 mm2.

Therefore 1 mW of sunlight would enter the eye.

For flux density at retina, use geometrical optics

r1 r2

o

i

i = (r2/r1)o ≈ 200 μm

Page 4: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Therefore at retina we have ~ 25 kW/m2.

Now consider a “weak” laser, 1 mW laser pointer with 1 mm2 beam.

Again 1 mW of light enters the eye.

However, unlike the sun, laser light is highly spatially coherent (as if from a point source) and so is focussed to the theoretical minimum spot size – d ~ fφ, where f is the focal length ( about 2 cm) and φ the beam angular divergence, typically 1 mrad.

This gives d = 20 μm or 2.5 MW/m2 at the retina.

100 times stronger than staring at the sun!

Page 5: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

• Based on published guidance, the University has adopted administrative procedures to ensure that risks associated with laser work are minimised.

• Details of these administrative procedures are contained within the handout.

• However, it should be remembered that lasers are being used in lots of different ways across the campuses and there is no “one size fits all” approach to laser safety – local risk assessment is essential.

• In this talk I will concentrate on some of the practical aspects of laser safety at the University of Nottingham.

Page 6: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser Classification

• It is a legal requirement for suppliers to classify the lasers they sell.

• Classes 1(1M) – 2(2M) – 3R/3A – 3B – 4 (in increasing order of ability to do harm)

• However, some older systems may not have appropriate labels.

• The class can be worked out using the “yellow book” and knowing the wavelength, power and pulse width (if pulsed) of the laser. – Example (calculation on the board):

Page 7: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser Classification

Page 8: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser Classification

• Class 1

• The most limiting MPE values cannot be exceeded and no specific safety controls are required.

• For CW visible lasers, the maximum limit is 70 microwatts.

• Class 1 operation cannot be claimed for a product containing an embedded laser of a higher class unless full-interlocked high-integrity enclosures using fail-safe interlocks are incorporated.

• Class 1M is a large diameter or widely divergent beam (302.5 – 4000 nm).

• Class 2

• Visible lasers only, for which the MPE cannot be exceeded in less than 0.25 seconds.

• For CW laser the limit is 1 mW.

• Class 2M is a large diameter or widely divergent beam.

Page 9: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser Classification

• Class 3R

• 302.5 – 106 nm

• Lower risk than 3B, but direct viewing of beam potentially hazardous

• Visible lasers up to five times the Class 2 limits and invisible lasers up to five times the Class 1 limits, for which specific H (Jm-2) or E(Wm-2) values are not exceeded.

• Class 3B

• Visible and invisible lasers not exceeding specified limits, which are 0.5W for CW lasers and 105 Jm-2 for pulsed lasers (less for ultraviolet wavelengths).

• Direct beam viewing not safe to the eye, specularly reflected beams may also be harmful to the eye, diffusely reflected beam usually safe to the eye, assumed to be safe to the skin.

• Class 4

• Those that exceed the limits of Class 3B!

• Viewing a direct beam or a reflected beam is always harmful to the eye and skin, diffusely reflected beams should be assumed harmful to the eye or skin unless proven otherwise, both scattered and reflected beams can present a fire hazard.

Page 10: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Notes on Practical Laser Safety

• The general safety precautions fall under very simple headings.

• a) Use of a remote interlock connector• b) Key control• c) Beam stop or attenuator• d) Warning signs• e) Beam paths• f) Specular reflections• g) Eye protection

Page 11: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser Eyewear

• Eyewear is the most common and certainly the most important aspect of personal laser protection, wherever there is some risk of laser exposure above the specified MPEs. Protective eyewear does not, however, preclude a full safety evaluation and consideration of all alternative means of affording protections - such as total enclosure of the beam, interlocks, beam dumps etc. Laser safety glasses are the last line of defence and not a convenient alternative to avoiding any engineering controls that it may be possible to implement.

Page 12: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Procedure for Selection of Eye Protection

Step 1: • Determine wavelength of laser (l) • Determine maximum exposure duration (t)

anticipated for the use of eye protection – unintentional, accidental exposure to a visible beam

where the maximum exposure may be of the order of 0.25 sec (aversion response).

– unintentional, accidental viewing of near IR laser beams for up to 10 sec.

– situations where occasional viewing of diffuse visible reflections for up to 600 sec is anticipated.

– 4 to 8 hour occupational viewing of a diffuse reflection (generally from an invisible beam).

Page 13: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Procedure for Selection of Eye Protection

Step 2:

Determine Maximum Permissible Exposure (MPE) for desired laser

• Determine MPE from l, maximum exposure duration (t), and viewing conditions determined in Step 1. MPE will be in units of [J/cm2] for pulsed lasers and [W/cm2] for CW lasers. Example (calculation on the board):

Page 14: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Procedure for Selection of Eye Protection

Page 15: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Procedure for Selection of Eye Protection

Step 3: • Determine the desired optical density • REMEMBER: MPE was determined in Step 2!

– Calculate Optical Density for a CW laser:

• Dl = Optical Density for CW laser

• = log10(H/MPE) – Calculate Optical Density for a pulsed laser:

• Dl = Optical Density for pulsed laser

• = log10(E/MPE)

Page 16: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Procedure for Selection of Eye Protection

Step 4: • Choose laser eye protection that meets the Optical

Density requirements for the laser • Compare the calculated requirements with manufacturer's

specifications and find eyewear with an optical density value equal to or greater than the calculated value.

• Additional factors in choosing laser eyewear – side-shield protection – peripheral vision requirement – need for prescription glasses – comfort and fit – degradation of absorbing media (photo bleaching) – strength of materials – anti-fog – impact requirements

Page 17: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007
Page 18: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Limitations of Eye Protection

General • In general, eye protection will afford adequate protection against medium

power, Class 3 lasers but will seldom provide sufficient protection against direct beam viewing of CW lasers exceeding 10 W in power or pulsed lasers exceeding 10 to 100 J in output energy. Obviously, for the higher power lasers, if a plastic frame or lens bursts into flames the wearer is going to move out of the beam path very rapidly. In these situations, the laser user should attempt to eliminate the need for eye protection when using such high power lasers by using engineering controls.

Multiple Wavelengths • One pair of laser eyewear may not provide adequate protection from all

multiple or tunable wavelengths produced by the laser. The laser user must be very conscious of which type of eye protection is appropriate for each different wavelength which may be used in the operation of the laser. It is the responsibility of the laser equipment supervisor to assure that the appropriate eyewear (for each wavelength) is provided for all users of the laser.

Page 19: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

University safety officer

University laser safety adviser

School/Dept. laser safety officer

Laser lab/project supervisor

Laser workers

Who’s who in laser safety:

Page 20: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Breakdown of Responsibilities

• University

• Safety Office

• To keep a register of all laser users and all lasers.

• To carry out periodic checks on designated laser areas in departments and the records kept..

• To provide DLSO’s with adequate support in their roles.

• To provide yearly a training course for all new laser users

• DLSO

• To register new users

• To provide users with the CVCP Yellow Book

• To carry out yearly audits of designated laser areas

• To follow up on any problem areas identified in the audits

• To give advice on appropriate training for users where requested by either the user or a supervisor

Page 21: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Breakdown of Responsibilities

• Supervisors

• To write a protocol for work to be carried out in any area where Class IIIR, Class IIIb and Class IV lasers are used.

• To provide adequate personal safety equipment for users

• To act promptly on the advice of the DLSO following an audit of the DLA

• (Undergraduates only) To have provide a copy of the ‘Approved Scheme of Work’ for a project

• (Postgraduate/post doctoral only) To have ensured that the Project Supervisory Requirements Form’ has been updated and carried entries of risk assessments

associated with the use of lasers.

Page 22: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Breakdown of Responsibilities - Individuals • To complete the medical eye survey form if required.

• To view the laser safety video

• To read and have a working knowledge of the CVCP yellow book and to know the location of the laboratory copy

• To understand access restrictions in designated laser areas and the operation of any laboratory door interlocks

• To know the location and capabilities of laser safety equipment

• To calculate representative MPE figures for the system(s) being used

• (Undergraduates only) To have read, signed, and approved a copy of an ‘Approved Scheme of Work’ written by the supervisor for the project

• (Postgraduate/post doctoral only) To have ensured that the Project Supervisory Requirements Form’ has been updated and carried entries

of risk assessments associated with the use of lasers.

Page 23: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Laser User Registration

Academic supervisor to inform user to Register as a laser user

User completes registration User completer medical form, supervisor signs and copies eye survey form if using 3B/4 lasers and sends to OH SLS* authorises form and maintains OH sends letter A record of users for the School confirming “safe to work with

lasers” to SLS & Safety Office

User must be provided With suitable training

(- university intro course - School course

- Laser system training) Training recorded

(PRSF, course registers)

Laser User may commence laser work With suitable supervision.

(I f Student, PSRF reviewed until user is competent)

*SLS - School Laser Supervisor #OH - Occupational Health

Page 24: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Requirements for all new research workers who will be registered laser users

• If the research worker arrives after the start of the academic year they must obtain the Laser Safety Video from DLSO and, as above, sign a statement indicating if they did understand the video and the documentation given to them.

• If at any time a research worker feels that they have not understood the laser safety protocol and the general recommendations outlined, or that they are unsure about these recommendations as they pertain to the designated laser area in which they work, they should approach their supervisor who will discuss with the DLSO what further training is appropriate for the situation.

Page 25: Laser Safety Training Prof Tony Kent University Of Nottingham 4 th . October 2007

Summary of Laser Administration Process

Laser Registrations

New laser to be put into use (or change of status for existing laser)

Principle investigator (laser "owner") to register laser

on university form (all 3R & above)

Registration form sent to SLS* and Safety Office

SLS to authorise & Safety Office maintain inventory Ensure laser survey of lasers and check laser & risk assessment installation if necessary completed

Laser may be put into use - annual laser survey

- list of users - risk assessment - written protocol

Annual update of laser inventory confirmed with School Annual inspection by Safety Office (since 2003/4)

Change of laser or taking laser out of use: School to notify Safety Office via registration form

* SLS School Laser Supervisor