Exceptional Quality Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED CHIRAL SEPARATIONS

Upload: doannguyet

Post on 05-Feb-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

• Exceptional Quality

• Sensibly Priced

Lux Cellulose-1Guaranteed Alternative to CHIRALCEL® OD-H®

SIMPLIFIED CHIRAL SEPARATIONS

Page 2: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

Proven universal selector •

Available in 3 µm, 5 µm, and 20 µm •

Sensibly priced•

Stable up to 300 bar (4,350 psi)•

Easy solvent switching •

H

HH

H

HC

C

H

HH

C

C

H

HH

H

O

O

C

H

N

O

HH

C

C

C

C

C

CC

H

H

H

H

O

O

O

N

C

O

H

N

HH

H

HH

C

C

H

O

H

Lux Cellulose-1Cellulose tris(3,5-dimethylphenylcarbamate)

Meet the Rest of the Lux Family!

The Lux line of CSPs offers 5 complementary selectivities

© 2010 Phenomenex, Inc. All rights reserved.

Advantages of using Lux Cellulose-1

This dimethyl cellulose selector is famous around the world for its ability to separate aromatic, conjugated, and other challenging chiral compounds.

C-1 C-2 A-2

Cellulose Backbone Cellulose Backbone

C-3

Cellulose Backbone

C-4

Cellulose Backbone Amylose Backbone

H

H HC

H

H

HH

H

CC

H

Cl

H

H C H

C

Cl

O

HH

H

Cl

H

HC

H

Lux Cellulose-2cellulose tris(3-chloro-4- methylphenylcarbamate)

Chlorinated Cellulose

C-1 C-2 A-2

Cellulose Backbone Cellulose Backbone

C-3

Cellulose Backbone

C-4

Cellulose Backbone Amylose Backbone

H

H HC

H

H

HH

H

CC

H

Cl

H

H C H

C

Cl

O

HH

H

Cl

H

HC

H

Cellulose Ester

Lux Cellulose-3cellulose tris(4-methylbenzoate)

C-1 C-2 A-2

Cellulose Backbone Cellulose Backbone

C-3

Cellulose Backbone

C-4

Cellulose Backbone Amylose Backbone

H

H HC

H

H

HH

H

CC

H

Cl

H

H C H

C

Cl

O

HH

H

Cl

H

HC

H

Chlorinated Cellulose

Lux Cellulose-4cellulose tris(4-chloro-3- methylphenylcarbamate)C-1 C-2 A-2

Cellulose Backbone Cellulose Backbone

C-3

Cellulose Backbone

C-4

Cellulose Backbone Amylose Backbone

H

H HC

H

H

HH

H

CC

H

Cl

H

H C H

C

Cl

O

HH

H

Cl

H

HC

H

Lux Amylose-2amylose tris(5-chloro-2- methylphenylcarbamate)

Chlorinated Amylose

Phenomenex l WEB: www.phenomenex.com

Page 3: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

3

Ambucetamide

Nomifensine

0

17412

2 4

1

2

6 8 min

0 2

2

17414

4 6 81

1

3 5 7 9 min

2

2

431

1

0 5

17422

min

0 1 2

21

3 4 5 min

17423

0 2 4

1 2

6 min

17454

0 2

21

4 51 3 min

17456

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Methanol /

0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Acetonitrile /

0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Acetonitrile /

0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Lux 5 µm Cellulose-1a = 2.09

Lux 5 µm Cellulose-1a = 1.38

*CHIRALCEL® 5 µm OD-H®

a = 1.83

*CHIRALCEL® 5 µm OD-H®

a = 1.18

Lux 5 µm Cellulose-1a = 1.20

*CHIRALCEL® 5 µm OD-H®

a = 1.11

O

OH2N

N

O

H

OH

H3COCH3

CH3NH

CH3

NH2

H

N

Guaranteed Alternative to CHIRALCEL® OD-H®

Ap

p ID

174

12A

pp

ID 1

7422

Ap

p ID

174

54A

pp

ID 1

7414

Ap

p ID

174

23A

pp

ID 1

7456

Metoprolol

Phenomenex l WEB: www.phenomenex.com

SIMPLIFIED CHIRAL SEPARATIONS

If Lux analytical columns (≤ 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 45 days and keep the Lux column for FREE.

Page 4: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

4

0 1 2 3 4 5 6 min

1

17321

2

0 2

2

1

4 6 min

17322

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Hexane /

0.1 % Diethylamine in Isopropanol (90:10) Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Lux 5 µm Cellulose-1a = 1.09

*CHIRALCEL® 5 µm OD-H®

a = 1.07

N

O

H3CCH3

0 2 3

2

1

41 5 6 min

17404

0 2 3 51

2

1

4 6 min

17405

0 2

21

4 6 81 3 5 7 min

17415

0 2

2

4 6 81

1

3 5 7 min

17417

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Acetonitrile /

0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Methanol /

0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Lux 5 µm Cellulose-1a = 1.31

*CHIRALCEL® 5 µm OD-H®

a = 1.20

Lux 5 µm Cellulose-1a = 1.39

*CHIRALCEL® 5 µm OD-H®

a = 1.28

OH

H3C

Cl

O

N

N

Specialized Coating Process and Expert Packing Provides Optimal Column Performance.

Cl

O

N

O

Ap

p ID

173

21A

pp

ID 1

7404

Ap

p ID

174

15A

pp

ID 1

7322

Ap

p ID

174

05A

pp

ID 1

7417

Tolperisone

Metofoline

Our robust coating and packing process allows you to enjoy increased loading capacity, column reproducibility, and exceptional enantiomeric resolution. Achieve the optimal efficiencies you desire without sacrificing chiral recognition abilities.

Temazepam

Phenomenex l WEB: www.phenomenex.com

Page 5: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

5

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Methanol /

0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/min

Temperature: AmbientDetection: UV @ 220 nm

Extreme Stability and Separating Power under SFC Conditions.

18855

0 2

2

1

4 6 8 10 12 14 16 18 20 22 24 min

0 2

2

1

19098

4 6 8 10 12 14 16 18 20 22 24 min

0 2

2

1

19100

4 6 8 10 12 14 16 18 20 22 24 26 28 min

0 2

1

2

4 6 8 10 12 14 16 18 20 22 24 26 28 min

19101

Atenolol

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Methanol /

Carbon Dioxide (20:80)Flow Rate: 2.5 mL/min

Temperature: 35 °CDetection: Diode Array Detector

Conditions for both columns:

Dimensions: 250 x 4.6 mmMobile Phase: 0.1 % Diethylamine in Methanol /

Carbon Dioxide (15:85)Flow Rate: 2.5 mL/min

Temperature: 35 °CDetection: Diode Array Detector

Bifonazole

Lux 5 µm Cellulose-1a = 1.08

Lux 5 µm Cellulose-1a = 1.97

*CHIRALCEL® 5 µm OD-H®

a = 1.02

*CHIRALCEL® 5 µm OD-H®

a = 1.64

N

N

O

O

OH

HN

H2N

CH3

CH3

H

Ap

p ID

191

00A

pp

ID 1

8855

Ap

p ID

191

01A

pp

ID 1

9098

Never fear crushed media or loss in efficiency again. With a pressure stability up to 300 bar (4,350 psi), you can feel confident about running at high operating pressures (if necessary). Lux media is SFC approved and versatile enough to satisfy all of your chiral separation needs.

Phenomenex l WEB: www.phenomenex.com

SIMPLIFIED CHIRAL SEPARATIONS

Page 6: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

6

Easy Chiral Method Development

Chiral Phase Screening•

Method Optimization•

Method Re-Validation•

Scale-Up Services•

On-Site Training•

For more information on our services or to begin a project, please contact your local Phenomenex chiral expert or email us at: [email protected]

You can also visit us on the web: www.phenomenex.com/phenologics

*Based on screening 233 compounds on all five Lux Phases

Chiral Screening and Separation ServicesHPLC | SFC | Preparative | Training

Phenomenex l WEB: www.phenomenex.com

Resolve 92 % of your enantiomers with five complementary Lux™ phases.*

To get you started, we have outlined a simple strategy for screening CSPs under HPLC and SFC conditions in our chiral method development solutions poster.

Call or go online today to create your own custom screening kit or to request a chiral method development solutions poster at www.phenomenex.com/info/lux

Page 7: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

7

Ordering Information

*SecurityGuard Analytical Cartridges require holder, Part No. : KJ0-4282‡SemiPrep SecurityGuard Cartridges require holder, Part No. : AJ0-7220

**PREP SecurityGuard Cartridges require holder, Part No. : AJ0-8223+PREP SecurityGuard Cartridges require holder, Part No. : AJ0-8277

Phenomenex l WEB: www.phenomenex.com

SIMPLIFIED CHIRAL SEPARATIONS

If Lux analytical columns (≤ 4.6 mm ID) do not provide at least an equivalent or better separation as compared to a competing column of the same particle size, similar phase and dimensions, send in your comparative data within 45 days and keep the Lux column for FREE.

Column Performance Check StandardPart No. Description Unit Price

AL0-8412 Chiral Test Mix No. 5 (Lux) ea

3 µm Method Screening Kits (save 10 % when purchased as a kit)

50 x 4.6 mm 250 x 4.6 mm

Screening Kit KH0-8483 KH0-8482Kit contains one column of each phase.

5 µm Semi-Prep Columns (mm)SecurityGuard™ Cartridges (mm)

150 x 10.0 250 x 10.0 10 x 10.0‡

Phases /3pk

Cellulose-1 00F-4459-N0 00G-4459-N0 AJ0-8404

Cellulose-2 00F-4457-N0 00G-4457-N0 AJ0-8399

Cellulose-3 00F-4493-N0 00G-4493-N0 AJ0-8623

Cellulose-4 00F-4491-N0 00G-4491-N0 AJ0-8628

Amylose-2 00F-4472-N0 00G-4472-N0 AJ0-8472

for ID: 9–16 mm

5 µm Axia™ Packed Preparative Columns (mm) SecurityGuard™ Cartridges (mm)150 x 21.2 250 x 21.2 250 x 30 250 x 50 15 x 21.2** 15 x 30.0+

Phases /ea /ea

Cellulose-1 00F-4459-P0-AX 00G-4459-P0-AX 00G-4459-U0-AX 00G-4459-V0-AX AJ0-8405 AJ0-8406

Cellulose-2 00F-4457-P0-AX 00G-4457-P0-AX 00G-4457-U0-AX 00G-4457-V0-AX AJ0-8400 AJ0-8401

Cellulose-3 00F-4493-P0-AX 00G-4493-P0-AX 00G-4493-U0-AX 00G-4493-V0-AX AJ0-8624 AJ0-8625

Cellulose-4 00F-4491-P0-AX 00G-4491-P0-AX 00G-4491-U0-AX 00G-4491-V0-AX AJ0-8629 AJ0-8630

Amylose-2 00F-4472-P0-AX 00G-4472-P0-AX 00G-4472-U0-AX 00G-4472-V0-AX AJ0-8473 AJ0-8474

for ID: 18 –29 mm 30–49 mm

3 µm Analytical Columns (mm) SecurityGuard™ Cartridges (mm)50 x 2.0 150 x 2.0 50 x 4.6 100 x 4.6 150 x 4.6 250 x 4.6 4 x 2.0* 4 x 3.0*

Phases /10pk /10pk

Cellulose-1 00B-4458-B0 00F-4458-B0 00B-4458-E0 00D-4458-E0 00F-4458-E0 00G-4458-E0 AJ0-8402 AJ0-8403

Cellulose-2 00B-4456-B0 00F-4456-B0 00B-4456-E0 00D-4456-E0 00F-4456-E0 00G-4456-E0 AJ0-8398 AJ0-8366

Cellulose-3 00B-4492-B0 00F-4492-B0 00B-4492-E0 00D-4492-E0 00F-4492-E0 00G-4492-E0 AJ0-8621 AJ0-8622

Cellulose-4 00B-4490-B0 00F-4490-B0 00B-4490-E0 00D-4490-E0 00F-4490-E0 00G-4490-E0 AJ0-8626 AJ0-8627

Amylose-2 00B-4471-B0 00F-4471-B0 00B-4471-E0 00D-4471-E0 00F-4471-E0 00G-4471-E0 AJ0-8471 AJ0-8470

for ID: 2.0 –3.0 mm 3.2–8.0 mm

5 µm Analytical Columns (mm) SecurityGuard™ Cartridges (mm)50 x 2.0 50 x 4.6 100 x 4.6 150 x 4.6 250 x 4.6 4 x 2.0* 4 x 3.0*

Phases /10pk /10pk

Cellulose-1 00B-4459-B0 00B-4459-E0 00D-4459-E0 00F-4459-E0 00G-4459-E0 AJ0-8402 AJ0-8403

Cellulose-2 00B-4457-B0 00B-4457-E0 00D-4457-E0 00F-4457-E0 00G-4457-E0 AJ0-8398 AJ0-8366

Cellulose-3 00B-4493-B0 00B-4493-E0 00D-4493-E0 00F-4493-E0 00G-4493-E0 AJ0-8621 AJ0-8622

Cellulose-4 00B-4491-B0 00B-4491-E0 00D-4491-E0 00F-4491-E0 00G-4491-E0 AJ0-8626 AJ0-8627

Amylose-2 00B-4472-B0 00B-4472-E0 00D-4472-E0 00F-4472-E0 00G-4472-E0 AJ0-8471 AJ0-8470

for ID: 2.0–3.0 mm 3.2–8.0 mm

Terms and Conditions Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions.

Trademarks CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Axia, Lux, and SecurityGuard are trademarks of Phenomenex, Inc.

Disclaimer Comparative separations may not be representative of all applications. Columns used for comparison were manufactured by DAICEL Chemical Industries, Ltd. Phenomenex is not affiliated with DAICEL Chemical Industries.

© 2010 Phenomenex, Inc. All rights reserved.

20 µm Bulk Media100 g 1 kg

Phases

Cellulose-1 04G-4473 04K-4473

Cellulose-2 04G-4464 04K-4464

Amylose-2 ∆ ∆

∆Please inquire for 20 µm Lux Amylose-2, Cellulose-3 or Cellulose-4 media.

Page 8: Lux Cellulose-1 - Phenomenexphx.phenomenex.com/lib/br73940210_i.pdf · •Exceptional Quality • Sensibly Priced Lux Cellulose-1 Guaranteed Alternative to CHIRALCEL ® OD-H ® SIMPLIFIED

t: f:

Australia02-9428-6444 02-9428-6445 [email protected]

t: f:

Austria 01-319-1301 01-319-1300 [email protected]

t: f:

Belgium+31 (0)30-2418700 +31 (0)30-2383749 [email protected]

t: f:

Canada(800) 543-3681 (310) 328-7768 [email protected]

t: f:

Denmark4824 8048 4810 6265 [email protected]

t: f:

Finland(09)4789 0063 +45 4810 6265 [email protected]

t: f:

France01 30 09 21 10 01 30 09 21 11 [email protected]

t: f:

Germany 06021-58830-0 06021-58830-11 [email protected]

t: f:

Ireland 01 247 5405 +44 1625-501796 [email protected]

t: f:

Italy 051 6327511 051 6327555 [email protected]

t: f:

Luxembourg+31 (0)30-2418700 +31 (0)30-2383749 [email protected]

t: f:

Mexico(55) 5018 3791 (310) 328-7768 [email protected]

t: f:

The Netherlands030-2418700 030-2383749 [email protected]

t: f:

New Zealand09-4780951 09-4780952 [email protected]

t: f:

Norway 81 00 20 05 +45 4810 6265 [email protected]

t: f:

Puerto Rico (800) 541-HPLC (310) 328-7768 [email protected]

t: f:

United Kingdom 01625-501367 01625-501796 [email protected]

t: f:

All other countries: Corporate Office USA (310) 212-0555 (310) 328-7768 [email protected]

www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at [email protected]

BR

7394

0210

_I