managing demand in commercial infrastructure...bacnet rest other lower/raise setpoint i/o bms and/or...
TRANSCRIPT
![Page 1: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/1.jpg)
Managing Demand inCommercial Infrastructure
Karl Zimmerman
CEO, EnergyIQ GROUP, LLC
![Page 2: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/2.jpg)
Where We Play
![Page 3: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/3.jpg)
Demand Management The Concepts
Energy Efficiency• Use less power to perform same tasks
Demand Response• Any reactive or preventative method to
reduce, flatten or shift demand Distributed Energy Resources
• Dispatch of alternative energy assets
![Page 4: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/4.jpg)
Energy Efficiency Strategies
Demand Control Ventilation• Reduce OA Usage based on CO2
Temperature / Fan / Pump Resets• Reset supply temperatures based on
varying conditions Cogeneration Net Zero Energy
![Page 5: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/5.jpg)
Demand Response Strategies
![Page 6: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/6.jpg)
Distributed Energy Resource Strategies
Renewable Energy/BESS• Optimize dispatch of Battery and Renewable assets
Base-loaded Natural Gas Generators• Prime power movers• Highly EPA-compliant catalytic converters
Stand-by Generators• Limited in some areas due to emissions (100hrs/yr)
![Page 7: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/7.jpg)
Demand Management Architecture
SSL Secure Internet
Connection
Plant “Reduce Load”
Power/Lighting“Circuit 1, 2 Off”
Control Center
Start NG Generator
Control Dashboard
Customer Site
Customer BMS/SCADA
ModbusDNP3
BACnetRESTOther
Lower/Raise Setpoint
I/O
BMS
AND/ORlinkIQ Interface
Dispatch Battery / PV
System
![Page 8: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/8.jpg)
Demand Management Implementation
Product Features Key Customers
Based on ILC-2050BI UL508 Industrial Grade Demand Management
“Adapter” Niagara 4 “.jar file” SSL-based REST Interface Direct CSP Connection
(Curtailment Service Provider) SCADA/BMS Integration Bid Award Notification Real-time kW Metering Real-time Event Notification DR Program Compliance Web Interface
![Page 9: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/9.jpg)
Demand Management Implementation
![Page 10: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/10.jpg)
Demand Profile Dashboard
![Page 11: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/11.jpg)
Demand Management Control
![Page 12: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/12.jpg)
Opportunity
Integrating Back of House loads to DR in Hotels
Dispatching Renewable Energy assets
Integrating to manufacturing SCADA
Distributed Generation HVAC, Lighting, Vehicle
Charging Stations, Plug loads Ventilation Equipment Any other discretionary loads Bid/Award Market Project Financing
![Page 13: Managing Demand in Commercial Infrastructure...BACnet REST Other Lower/Raise Setpoint I/O BMS AND/OR linkIQInterface Dispatch Battery / PV System Demand Management Implementation Product](https://reader035.vdocuments.net/reader035/viewer/2022071607/6144cedb34130627ed5095f5/html5/thumbnails/13.jpg)
Have Questions?https://www.linkedin.com/in/karl-zimmerman-5096a213/