manual 7sj62-63-64 v44

Click here to load reader

Post on 14-Apr-2015

162 views

Category:

Documents

11 download

Embed Size (px)

TRANSCRIPT

Preface Table of Contents Introduction

SIPROTEC Multi-Functional Protective Relay with Local Control 7SJ62/63/64V4.4

Functions Installation and Commissioning Technical Data Appendix Index

1 2 3 4 A

Manual

C53000-G1140-C1471

Liability Statement We have checked the text of this manual against the hardware and software described. Exclusions and deviations cannot be ruled out; we accept no liability for lack of total agreement. The information in this manual is checked periodically, and necessary corrections will be included in future editions. We appreciate any suggested improvements. We reserve the right to make technical improvements without notice. Release 4.40.02

Copyright Copyright Siemens AG 2002. All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. Registered trademarks SIPROTEC, SIMATIC, SIMATIC NET , SINAUT , SICAM, and DIGSI are registered trademarks of Siemens AG. Other designations in this manual may be trademarks that if used by third parties for their own purposes may violate the rights of the owner.

Siemens Aktiengesellschaft Buch-Nr. C53000-G1140-C1471

PrefacePurpose of This Manual This manual describes the functions, operation, installation, and placing into service of the devices 7SJ62, 7SJ63 and 7SJ64. In particular, one will find: Descriptions of device functions and settings Chapter 2; Instructions for mounting and commissioning Chapter 3; Compilation of technical specifications Chapter 4; As well as a compilation of the most significant data for experienced users in the Appendix. General information about design, configuration, and operation of SIPROTEC devices are laid down in the SIPROTEC 4 system manual, order no. E50417H1176 C151. Target Audience Protection engineers, commissioning engineers, personnel concerned with adjustment, checking, and service of selective protective equipment, automatic and control facilities, and personnel of electrical facilities and power plants. This manual is valid for: SIPROTEC 4 7SJ62/63/64 Multifunction Protective Relays; firmware version 4.4. Indication of Conformity This product complies with the directive of the Council of the European Communities on the approximation of the laws of the member states relating to electromagnetic compatibility (EMC Council Directive 89/336/EEC) and concerning electrical equipment for use within certain voltage limits (Low-voltage Directive 73/23/EEC). This conformity is proved by tests conducted by Siemens AG in accordance with Article 10 of the Council Directive in agreement with the generic standards EN 50081 and EN 50082 for EMC directive, and with the standard EN 602556 for the low-voltage directive. The product conforms with the international standard of the series IEC 60255 and the German standard DIN 57435 /Part 303 (corresponds to VDE 0435/Part 303).

Applicability of This Manual

ANSI

This product has been designed according to ANSI C37.90.* standards.

7SJ62/63/64 Manual C53000-G1140-C147-11

i

Preface

This product is ULcertified with the data as stated in Section 4.1:

IND. CONT. EQ. TYPE 1 69CA

IND. CONT. EQ. TYPE 1

Additional Support

Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purpose, the matter should be referred to the local Siemens representative. Individual course offerings may be found in our Training Catalogue, or questions may be directed to our training center. Please contact your Siemens representative. The warnings and notes contained in this manual serve for your own safety and for an appropriate lifetime of the device. Please observe them! The following terms are used:

Training Courses

Instructions and Warnings

DANGERindicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken.

Warningindicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken.

Cautionindicates that minor personal injury or property damage can result if proper precautions are not taken. This particularly applies to damage on or in the device itself and consequential damage thereof. Note indicates information about the device or respective part of the instruction manual which is essential to highlight.

Warning!Hazardous voltages are present in this electrical equipment during operation. Non observance of the safety rules can result in severe personal injury or property damage. Only qualified personnel shall work on and around this equipment after becoming thoroughly familiar with all warnings and safety notices of this manual as well as with the applicable safety regulations. The successful and safe operation of this device is dependent on proper handling, installation, operation, and maintenance by qualified personnel under observance of all warnings and hints contained in this manual. In particular the general erection and safety regulations (e.g. IEC, DIN, VDE, EN or other national and international standards) regarding the correct use of hoisting gear must be observed. Nonobservance can result in death, personal injury or substantial property damage.

ii

7SJ62/63/64 Manual C53000-G1140-C147-11

Preface

QUALIFIED PERSONNEL For the purpose of this instruction manual and product labels, a qualified person is one who is familiar with the installation, construction and operation of the equipment and the hazards involved. In addition, he has the following qualifications: Is trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in accordance with established safety practices. Is trained in the proper care and use of protective equipment in accordance with established safety practices. Is trained in rendering first aid. Typographic and Symbol Conventions The following text formats are used when literal information from the device or to the device appear in the text flow: Parameter names, i.e. designators of configuration or function parameters which may appear word-for-word in the display of the device or on the screen of a personal computer (with operation software DIGSI 4), are marked in bold letters of a monospace type style. Parameter options, i.e. possible settings of text parameters, which may appear word-for-word in the display of the device or on the screen of a personal computer (with operation software DIGSI 4), are written in italic style, additionally. Annunciations, i.e. designators for information, which may be output by the relay or required from other devices or from the switch gear, are marked in a monospace type style in quotation marks. Deviations may be permitted in drawings when the type of designator can be obviously derived from the illustration. The following symbols are used in drawings:Earth fault

device-internal logical input signal device-internal logical output signal internal input signal of an analogue quantity external binary input signal with function number Fno external binary output signal with function number Fno

Earth faultUL1L2FNo 567

>ReleaseFNo 5432

Dev. TripParameter address Parameter name

1234 FUNCTION On OffParameter options

example of a parameter switch designated FUNCTION with the address 1234 and the possible settings On and Off

Besides these, graphical symbols are used according to IEC 6061712 and IEC 6061713 or similar. Some of the most frequently used are listed below:

7SJ62/63/64 Manual C53000-G1140-C147-11

iii

Preface

Input signal of an analogue quantity

or

OR gate

&signal inversion

AND gate

=1

ExclusiveOR gate (antivalence): output is active, if only one of the inputs is active Coincidence gate (equivalence): output is active, if both input are active or inactive at the same time Dynamic inputs (edgetriggered) above with positive, below with negative edge Formation of one analogue output signal from a number of analogue input signals (example: 3)

=

2610 Iph>>

Iph> 2611 T Iph>> T 0

Limit stage with setting address and parameter designator (name)

Timer (pickup delay T, example adjustable) with setting address and parameter designator (name)

0

T

Timer (dropout delay T, example non-adjustable)

T

Dynamic triggered pulse timer T (monoflop)

S R

Q Q

Static memory (RSflipflop) with setting input (S), resetting input (R), output (Q) and inverted output (Q)

Furthermore, the graphic symbols according IEC 6061712 and IEC 6061713 or similar are used in most cases. n

iv

7SJ62/63/64 Manual C53000-G1140-C147-11

Table of Contents1 Introduction.......................................................................................................................................... 1 1.1 1.2 1.3 Overall Operation ................................................................................................................... 2 Applications ............................................................................................................................ 6 Characteristics........................................................................................................................ 9