maxim submodule optimizers...maxim standard module p-v curves v oc,max 35v v oc,max 43v design...

13
Maxim Submodule Optimizers Residential and Commercial DC Optimization

Upload: others

Post on 01-Feb-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

  • Maxim Submodule OptimizersResidential and Commercial DC Optimization

  • Submodule Optimization

    MaximOptimizer per 24 cells

    Simplicity Factory installed, no added system components or complexity

    Performance Three MPPT per module for granular performance optimization

    Value Reduce Capex and LCOE with longer strings and mismatch recovery

    Reliability Technology proven over 20 years in mission critical applications

    ConventionalBypass Diode per 24 cells

    | Maxim Integrated | 2

  • Limited By the Weakest Cell

    Deep MPPT Granularity

    • Conventional PV Modules are current limited by the weakest cell

    • Shaded, Soiled, Cracked, or Aged Cells weaken the entire string or are bypassed

    • Maxim Optimizers mitigate mismatch for up to 30% more power in a variety of challenged conditions

    Each Cell-String Optimized

    100W+100W-5W=195W 100W+100W+50W=250W

    | Maxim Integrated | 3

  • Flexible PV System Design

    • Residential Flexibility> String modules of different orientations in series

    > Combine strings of different length on a single MPP channel

    > No external boxes, gateways, trunk cabling, or network communications

    • Commercial> Increased number of modules per string; reduce homeruns

    > Tighter row pitch with minimal row-shade losses

    > Choose simplest stringing method without performance penalty

    • Shade and Soiling Tolerance> Design with fewer constraints to shading objects

    > Reduce cleaning and maintenance requirements

    | Maxim Integrated | 4

  • Residential System Design Flexibility

    Parallel Mismatch Operation Multiple Mounting PlanesSeries Mismatch Operation

    • Distributed MPPT enables flexible PV site design

    • No performance penalty design; use the “easiest” installation

    Directly combine strings of different length

    i.e. 10 panels in parallel with 12: +5% energy increase

    Series connect panels facing different directions

    i.e. East panels in series with West: +12% energy increase

    Series connect panels of different tilts

    i.e. 10° panels in series with 25°panels: +1.6% energy increase

    | Maxim Integrated | 5

  • Longer Strings

    • Limit 60-cell module output to 35V across all temperatures and irradiances

    • Enables more modules on small systems and fewer strings on large systems

    • Longer strings amortize fixed costs over more kW and enable lower effective $/W

    Enables 20-35% Longer StringsVoltage Limiting

    Maxim

    Standard

    Module P-V Curves

    VOC,MAX35V

    VOC,MAX43V

    Design Parameter Standard Maxim

    Min Design Temp* -10°C --

    Max VOC 43V 35V

    # Modules Per String

    600V 14 16

    1000V 23 26

    10-20% Longer strings enablessystem capex cost savings

    | Maxim Integrated | 6

    Voltage

    Po

    wer

  • Commercial System Design Flexibility

    • Mitigate effect of row shading caused by tight row pitches

    • Install more modules on area constrained systems

    • Enables 10-20% denser rooftop systems with no performance penalty

    0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

    An

    nu

    al E

    ne

    rgy

    Ground Coverage Ratio

    Energy Production vs Density

    Standard System +1-2% Energy

    High Density System+5-10% Energy

    Solar CellOptimizer

    Conventional or Panel Optimizer

    | Maxim Integrated | 7

  • Mismatch Tolerance

    • Many conditions unexpectedly and severely degrade system power production

    • Relax O&M requirements and impact of unforeseen environmental influences

    Shade MitigationSoiling Patterns

    0%

    5%

    10%

    15%

    20%

    25%

    0

    200

    400

    600

    800

    1000

    Ener

    gy B

    en

    efit

    Ener

    gy P

    rod

    uct

    ion

    (kW

    h)

    Monthly Energy ComparisonMaxim

    OEM

    Maxim Gain

    | Maxim Integrated | 8

  • Shaded Performance Example

    0

    500

    1,000

    1,500

    2,000

    Po

    we

    r (k

    W)

    DC Power

    MAX

    REF

    • Two palm trees equally affecting MAXIM and Panel Optimizer strings

    • Maxim submodule optimizer outperforms panel optimizer by > 4%

    String Energy (kWh)

    Maxim 21.7

    Other MLPE 20.8

    Gain 4.3%

    0%

    2%

    4%

    6%

    8%

    10%

    0

    5

    10

    15

    20

    25

    Gai

    n

    Ene

    rgy

    (kW

    h)

    DC Energy

    MAXREFGain

    Day 1 Day 2

    Day 1 Day 2

    | Maxim Integrated | 9

  • Installation Simplicity

    • No external boxes to install or communication networks to debug

    • Broad compatibility with string inverters from all manufacturers

    No Add-On Components Inverter Compatibility

    | Maxim Integrated | 10

  • Modeling with Maxim Submodule Optimizers

    • System design with Maxim optimizers is a built-in to the industry leading modeling tools

    Versions 2018R6 and later Later

    Versions 6.0 and later

    | Maxim Integrated | 11

  • Benefit

    Triple MPPT Per Module ✓

    Increase String Length ✓ ✓ ✓

    Increase Ground Coverage and Density ✓

    Eliminate Hot Spots & Diode Failures ✓

    Broad Inverter Compatibility ✓ ✓

    Proven High Reliability ✓

    Factory integrated, zero install time ✓ ✓

    Competitive Comparison

    The Only Module Integrated Optimization Solution

    Reduce Installation Costs, Improve Performance, Minimize Investment Risk

    | Maxim Integrated | 12