measurements of intense proton beams using optical transition radiation

25
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011

Upload: nowles

Post on 13-Jan-2016

51 views

Category:

Documents


2 download

DESCRIPTION

Measurements of Intense Proton Beams using Optical Transition Radiation. Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011. Transverse Beam Profile Methods for Protons. Invasive: Wires Single scanning wire – multi-pulse profiling - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Measurements of Intense Proton Beams using Optical Transition Radiation

Measurements of Intense Proton Beams using Optical Transition

Radiation

Vic Scarpine, Fermilab

TIPP 2011

Chicago, IL

June 10, 2011

Page 2: Measurements of Intense Proton Beams using Optical Transition Radiation

Transverse Beam Profile Methods for Protons

Invasive:1.Wires

– Single scanning wire – multi-pulse profiling

– Multi-wire – Single pulse profiling but more beam loss

– Survival?

Non-invasive:1.IPM – Ionization Profile Monitor – can be single pulse; expensive

2.Electron Wire – can be single pulse; expensive

3.Beam Fluorescence – similar to IPM but usually multi-pulse

Another possible invasive method is Optical Transition Radiation (OTR)– Why consider it?

6/10/2011 V. Scarpine - Fermilab 2

Page 3: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 3

Optical Transition Radiation

OTR is generated when a charged-particle beam transits the interface of two media with different dielectric constants– Surface phenomena

OTR detectors are primary beam instruments for electron machines– Far-field and Near-field imaging

A number of labs using OTR for proton profiling

– CERN, JPARC

Fermilab has developed a generic OTR detector for proton and antiproton beams

Far-field imaging Near-field imaging

6/10/2011

Page 4: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 4

Proton/Pbar OTR Detectors at FNAL

Fermilab Accelerator Complex

• Linac

• Booster

• Main Injector

• Tevatron

• Pbar Production

• NuMI

6/10/2011

Page 5: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 5

Proton/Pbar OTR Detectors at FNAL

TeV OTR– Next to IPM

– 150 GeV Proton & Pbar Injections

6/10/2011

Page 6: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 6

Proton/Pbar OTR Detectors at FNAL

TeV OTR– Next to IPM

– 150 GeV Proton & Pbar Injections

A150 OTR– 150 GeV Pbars

– Emittance

6/10/2011

Page 7: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 7

Proton/Pbar OTR Detectors at FNAL

TeV OTR– Next to IPM

– 150 GeV Proton & Pbar Injections

A150 OTR– 150 GeV Pbars

– Emittance

AP1 OTR– Up to 8e12 120

GeV protons at ~0.5 Hz

6/10/2011

Page 8: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 8

Proton/Pbar OTR Detectors at FNAL

TeV OTR– Next to IPM– 150 GeV Proton &

Pbar Injections

A150 OTR– 150 GeV Pbars– Emittance

AP1 OTR– Up to 8e12 120

GeV protons at ~0.5 Hz

NuMI OTR– Up to ~4e13 120

GeV protons at ~0.5 Hz

6/10/2011

Page 9: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 9

Diagram of Generic OTR Detector

• Radiation hardened CID camera– ~130 m pixels at foil

• Near field/far field focusing

• Tiltable camera to maintain focus across foil (Scheimpflug condition)

• Neutral density filter wheels with polarizers

– ~x1000 intensity range

• Bidirectional beam measurements with selectable foils

– 5 to 6 m aluminized Mylar or Kapton foils

– Foils replaceable in-situ

– 85 mm clear aperture

• Vacuum certified to few 10-9

6/10/2011

Page 10: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 10

• OTR detector just in front of shield wall– Next to target SEM profile monitor

• 6 m aluminized Kapton– ~1200 angstroms of aluminum

• Two foil design– Primary and Secondary foils

• Primary foil : ~6.5e19 protons

• Near-field and far-field imaging

• Measure beam shape for every pulse

• Operating at ~2e13 to 4e13 120 GeV protons per pulse at ~0.5 Hz– Beam size ~ 1 mm

– Up to 350 kW beam power

NuMI OTR Detector

SEMOTR

6/10/2011

Page 11: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 11

NuMI OTR Commissioning

Real-time pulse-by-pulse OTR data analysis

Gaussian fits to profiles -> centroid, sigma, intensity, 2D tilt, ellipticity

Auto-saving every 1000th beam OTR image -> tracking foil lifetime

Front-End Controls Display

6/10/2011

Page 12: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 12

Image Processing

• Camera is asynchronous to beam arrival• Use three images to reconstruct beam image• Filter image to remove noise

Sum = I1 + I2 – 2*I3

Three interlaced images

Filtered Image

6/10/2011

Page 13: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 13

Apply Image Calibration

Fiducial holes in foil give:• Scale• Orientation• Perspective correction

6/10/2011

Page 14: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 14

Images Over

Intensity

Beam intensities of 2.4e13 and 4.1e13

Gaussian fits to beam projections

Higher intensity beam has larger ellipticity and beam tilt

This show an advantage of a 2-D imaging device over 1-D profile monitors

6/10/2011

Page 15: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 15

Beam Centroids, OTR vs SEM

• Monitor OTR and SEM over many days• Compare X and Y beam centroid shapes• OTR and SEM give similar beam centroid positions

High IntensityBeam

High IntensityBeam

6/10/2011

Page 16: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 16

Beam , OTR vs SEM

x y

Detectors track each otherbut…• calibration error?• aging foil?

6/10/2011

Page 17: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 17

Foils Damage Under Intense Beams

Any darkening of foil or distortion of foil shape changes OTR distribution and intensity and hence the measurement of beam shape

The left photograph is of a 3 mil thick titanium vacuum window exposed to over 1020 120 GeV

protons. The center photograph is a similar vacuum window exposed to ~3x1018 120 GeV protons but with a smaller beam spot size. The right photograph is of our prototype OTR 20

m aluminum foil exposed to ~1019 120 GeV protons with a larger beam spot size.

6/10/2011

Vacuum Windows OTR Foil

Page 18: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 18

Is NuMI Foil Changing with Time?

Compare horizontal values of from OTR and SEM over ~80 day time period from primary foil

OTR appears to be slowly drifting away from SEM value

Is the OTR primary foil aging?

6/10/2011

Page 19: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 19

Primary Foil

Aging?

Operate primary foil ~3 months of continuous beam~6.5e19 protons

Insert secondary foil under similar beam conditions

Secondary foil generating ~25% more OTR

Is aluminized Kapton sputtering away?

6/10/2011

Page 20: Measurements of Intense Proton Beams using Optical Transition Radiation

Damage to NuMI Aluminized Kapton Foil

Aluminum Side Kapton Side

6/10/2011 V. Scarpine - Fermilab 20

~ 6.5e19 120 GeV protons

Page 21: Measurements of Intense Proton Beams using Optical Transition Radiation

Forward OTR Detector

6/10/2011 V. Scarpine - Fermilab 21

• Utilize target vacuum window as OTR generator

• Eliminate reflection of material• Less light collected than reverse OTR

• Compensate with amplified camera

Page 22: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 22

Conclusion

• NuMI OTR has operated for ~6.5e19 protons

• Beam position and measured for every pulse

• Primary 6 m aluminized Kapton foil shows aging

– Data shows aging effects– Foil show reflection changes

and mechanical distortion

• Switch to forward OTR detection

– Utilize vacuum window as OTR generator

– Eliminate reflection effect– Limited light collection

6/10/2011

Page 23: Measurements of Intense Proton Beams using Optical Transition Radiation

extra

6/10/2011 V. Scarpine - Fermilab 23

Page 24: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 24

Beam Centroid vs Intensity

X and Y beam centroid changes slightly with beam intensity

Note: difference in OTR and SEM mean position due to difference in (0,0) reference points.

6/10/2011

Page 25: Measurements of Intense Proton Beams using Optical Transition Radiation

V. Scarpine - Fermilab 25

Beam vs Intensity

OTR and SEM track each other with intensity but OTR has more scatter.Improvements in image processing may reduce scatter.

6/10/2011