mrslim(inverterseries r410a) catalog
DESCRIPTION
vrfTRANSCRIPT
-
L-179-13-MD034-A SI-1308 Printed in Japan(MDOC)New publication effective August. 2013
Specifications subject to change without notice.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANhttp://Global.MitsubishiElectric.com
Inverter Series
R410A
NEW!
SPLIT-TYPE AIR CONDITIONERS
L-179-13-MD034-A SI-1308 Printed in Japan(MDOC)New publication effective August. 2013
Specifications subject to change without notice.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANhttp://Global.MitsubishiElectric.com
Inverter Series
R410A
NEW!
SPLIT-TYPE AIR CONDITIONERS
-
Outdoor unit
Inverter Series 01-02
4hp3hp2.5hp2hp
PRODUCT LINE-UPRemote controller
Ceiling-cassette
Ceiling-suspended
Ceiling-concealed
PLY
PCY
PEY
INVERTER TECHNOLOGIESMitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result, optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy. Fast, comfortable operation and amazingly low running cost Thats the Mitsubishi Electric promise.
Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner. They receive information from sensors monitoring operat-ing conditions, and adjust the revolution speed of the compressor, which directly regulates air condi-tioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and providing the most comfortable room environment.
INVERTERS HOW THEY WORK
Simple comparison of air conditioner operation control with inverter and Non-inverter.
Non-inverter air conditioner repeats working and stopping operation to keep room temperature. Therefore, it brings lower energy-saving and uncomfortable operation.
TRUE COMFORT
Inverter Operation Image
PAM
Conventionalinverter
Merits of PAM Control Power increasedEfficient voltage increase realises increased power
Significant energy savingsRemarkable reduction in power loss saves electricity
Limited powerInsufficient power when needed
Limited energy savingsElectricity is wasted
Without PAM control With PAM controlSupplyvoltage
CurrentTime
Time
PAM adjusts the form of the current wave so that it becomes close to that of the supply voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
Magnetic torque+
Reluctance torque
DC compressor motor ( rotor )
Neodymiummagnets
PLY-P24BAPLY-P18BA PLY-P30BA PLY-P36BA optional
PCY-P24KAPCY-P18KA PCY-P30KA PCY-P36KA optionaloptional
optionalPEY-P24JAPEY-P18JA
SUY-KA18VA
PEY-P30JA PEY-P36JA
SUY-KA24VA SUY-KA30VA SUY-KA36VA
optional
Joint Lap DC Motor
Mitsubishi Electric has developed a unique motor, called the Poki-Poki Motor in Japan, which is manufac-tured using a joint lapping technique. This innovative motor operates based on a high-density, high-mag-netic force, leading to extremely high efficiency and reliability.
Rare Earth Magnet Rotor (Compressor)
An innovative motor with a rare earth magnet rotor is equipped in the compressor to ensure excellent efficiency. The rare earth magnet has a residual magnetic flux density threefold that of the previously used ferrite magnet.
Grooved Piping
High-performance grooved piping is used in heat exchangers to increase the heat exchange area.
PAM (Pulse Amplitude Modulation)
DC Fan Motor
A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much higher than an equivalent AC motor.
Reluctance DC Rotary Compressor
Powerful neodymium magnets are used in the rotor of the reluctance DC motor. More efficient operation is realised by strong mag-netic and reluctance torques produced by the magnets. (SUY-KA24/30/36VA Only)
Grooved piping
Cross-sectional viewPipe image
PAM is a technology that controls the current waveform so that it resembles the supply voltage wave, thereby reducing loss and realising more efficient use of elec-tricity. Using PAM control, 98% of the input power supply is used effectively.
Change in room temperature
Optimum Control of frequencykeeps preset room temperature
Inverter air conditioner
TimeCompressor operation
Minimum power operation
Constant room temperature
Pre
set
tem
per
atur
e
Compressor operation
Change in room temperature
On/off operation of compressor keeps room temperature
Non-inverter air conditioner
ON
Time
Full power
getting too hot getting too cool
Pre
set
tem
per
atur
e
ON ONOFF OFF
-
SERIESPLYSERIES
Advancements in PLY series improve style and performance for ensured indoor comfort
Wide Airflow
Wide-angle outlets distribute air-flow to all corners of the room, en-suring the room is sufficiently cooled/heated. Horizontal airflow and a fan speed reduced by 20% compared to conventional models also contribute to increased com-fort for occupants.
Conventional model
PLY-PBA
Less Cold Draft
The horizontal airflow function prevents cold drafts from striking the body directly, thereby keep-ing the body from becoming over-chilled.
Automatic air-speed adjustment
An automatic air speed adjustment mode is provided in addition to the four air-speed stages, of High, Medium 1, Medium 2, and Low. Air speed can be changed freely in accordance with a difference between the set temperature and the room temperature. The auto-matic air speed adjustment mode offers quick cooling of a room in high mode, such as at the starting up of cooling operation. After the room temperature is stabilized, the low mode will be applied automatically to maintain comfort.
Automatic vane shutter*
When the air conditioner is not operating, the vane shutter closes automatically to conceal the air outlet and create an aesthetically appealing flat surface.
Unit height of only 258mm (PLY-P18/24BA)
The high-power ceiling cas-settes offer a wide-flow air outlet that enables effective air conditioning of rooms with atrium ceilings up to 4.5m in height. The de-mands of high-ceiling applications such as halls, showrooms or shopping malls can now be fully answered thanks to this powerful yet highly effi-cient airflow.
Wide-flow air outlet
Pure White color harmonized with the interior dcor
A "Pure White" color is adopted for the decoration panel and wired remote controller so as to blend with any interior dcor.
Ceiling cassette models boast a slim body height for smooth and aes-thetic installation even in narrow plenum spaces.
Quiet Operation
An improved airflow path and powerful high-capacity flow fan contribute to the realisation of quieter operation.
Power flow fan
Other Features
Maximum upward draining of 850mmWireless remote controller availableDuct flange for Fresh-air IntakeBranch duct
Automatic Grille LoweringFunction (Option)
Easy to use/Simple maintenanceAn automatic grille lowering function capable of stopping at eight different heights is avail-able to simplify filter maintenance.
(comes with the automatic elevation panel)
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Automaticelevation to
4.0m
The i-see Sensor built into the optional corner panel eliminates uneven temperature distribution and reduces electricity consumption.
The i-see Sensor temperature-sensing technology improves energy efficiency and enhances room comfort
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor temperature through-out an entire room. When connected to the air conditioner control panel, the i-see Sensor works to maximize room comfort.
The i-see Sensor rotates 90 at intervals of 5sec,accurately measuring the temperature throughoutthe room (covering entire floor space).
i-see Sensor Operation
90rotation
90rotation
90rotation
5secmeasurement
5secmeasurement
5secmeasurement
5secmeasurement
Sensible temperature control prevents excessive cooling through pioneering control technologyBy measuring the inlet temperature and floor temperature, tempera-tures felt by the human body (sensible temperature) will be com-puted. This allows the proper sensible temperature to always be maintained through the suppression of excessive cooling.
Elevating (up-down) controller
optional
PLY-P18/24/30/36BA
(i-see Sensor: optional)
Inverter Series 03-04
4-way Ceiling Cassette
HighLow Automatic air- speed adjustmentMedium 2 Medium 1
*This feature will not activate when the vane is set at the fixed position.
(When using the wireless remote controller, an extra setting is required.)
Vane shutter closes automatically
During operation When turned off
PLY-P18/24BA
PLY-P30/36BA
PLY-P18/24BA PLY-P30/36BA
If required to set Low Ceiling Mode in a high humidity condition, please consult with dealers since there is some risk of condensation.
3-way 2.7 3.0 3.0 3.6 4.53.5
4-way 2.5 2.7 2.7 3.2 4.53.5
Specification according to ceiling height
(PLY-P30/36BA)
Horizontal airflow prevents drafty feeling
(optional corner panel)
The i-see Sensor automatically controls over-coolingby detecting the optimum temperatures.
Fixed condition Fixed condition
Temperature set at 26 27C, without the i-see Sensor
Temperature set at 28C, with i-see Sensor and automatic air-speed adjustment mode
Felt temperature: 26.5C Felt temperature: 28C
32C
23C
14C
28C
30 minutes
26.5C
Inlet temperature
Floor temperatureFelt temperature
28 C
30 minutes
26.5 CInlet temperature
Floor temperatureFelt temperature
No drops in felt temperature
Fixed condition Fixed condition
Felt temperature drops
Example When you want the felt temperature to be 28C.
With optional i-see Sensor corner panel
The felt temperature drops according to the drop in floor-level temperature. If the floor-level temperature is not monitored during long cooling operation, the felt temperature becomes chilly.
Air temperature is adjusted according to the floor temperature to keep the felt temperature at 28C.
-
PCYSERIESSERIES
A stylish indoor unit design and airflow settings for both high- and low-ceiling interiors expand installation possibilities
Stylish Indoor Unit Design
A stylish square-like design is adopted for the indoor units of all models. As a result, the units blend in better with the ceiling.
PC-GAKD
PCY-PKAOptional Drain Pump for Full-capacity Models
The pumping height of the optional drain pump has been increased from 400mm to 600mm, expanding flexibility in choosing unit location during installation work.
Drainage outlet canbe 600mm aboveceiling surface
Drain pump installationpossible
Ceilingsurface
Equipped with Automatic Air-speed Adjustment
In addition to the conventional 4-speed setting, units are now equipped with an automatic air-speed adjustment mode. This setting automatically adjusts the air-speed to conditions that match the room environment. At the start of cooling operation, the airflow is set to high-speed to quickly cool the room. When the room temperature reaches the desired setting, theairflow speed is decreased automatically for stable comfort-able cooling operation.
Start of cooling After room
temperature is stabilised
Strong Gentle
Fresh Outside-air Intake
Airflow volume (m3/min)
500
50100150200250300
0 1 2 3 4
Sta
tic p
ress
ure
(Pa)
Outside-air intake characteristics
PCY-P30/36KAPCY-P18/24KA
Flockless vanes
With the adoption of flockless vanes, dirt and other impurities can be cleaned off easily with mild household detergent.
optionaloptional
Ceiling-suspended
PCY-P18/24/30/36KA
PEYSERIESSERIES
The thin, ceiling-concealed indoor unitsof the PEY series are the perfect answerfor the air conditioning requirements of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving efficiency has been improved, thereby reducing electricity consumption and contributing to a further reduction in operating cost.
Compact Indoor Units
For all models, unit height are unified to 250mm. Compared to the previous model, the height size is reduced, allowing installation in tight spaces, such as ceiling cavities or drop-ceilings.
Air Inlet
The units with bottom inlet make more noise than those with rear inlet. It is recommended that the rear inlet be selected when install-ing the units in the rooms that should be quiet such as bedrooms.
Wide Selection of Fan Speeds and ExternalStatic Pressure
Five-stage external static pressure conversions and three fan speed selections are available. Capable of being set to a maxi-mum of 125Pa, units are applicable to a wide range of building types.
1Rear inlet 2Bottom inlet
PEY-P18/24/30/36JA
optionaloptional
250mm
Ceiling-concealed
External static pressure setting
Series
PEY-P.JA
18 24 30 36
35/50/70/100/125Pa
Reduction in height size
Air inlet
Air outlet Air outletAir inlet
Inverter Series 05-06
Units are equipped with a knock-out hole that enables the in-duction of fresh outside-air.
-
Inverter Series 07-08CONTROL TECHNOLOGIES
PAR-31MAA(Optional)
Easier to read thanks to use of a full dot liquid-crystal display with backlight, and easier to use owing to adopting a menu format that has reduced the number of operating buttons.
Energy-efficient Control
Operation Control Functions
Easy To Read & Easy To Use
Multi-language DisplayControl panel operation in eightdifferent languages
Display Example [Operation Mode]
Full Dot LCD
Using a temperature that is 1C higher for cooling results in a 10% reduction in power consumption.* Temperature Range Restriction limits the maximum and minimum temperature settings, contributing to the prevention of overcooling. *In-house calculations
Temperature Range Restrictionprevents overcooling
TemperatureRangeRestriction
When using Auto-off Timer, even if one forgets to turn off the unit, operation stops automatically after the preset time elapses, thereby preventing wasteful opera-tion. Auto-off Timer can be set in 10-minute units, in a range between 30 minutes and 4 hours. Eliminates all anxiety about forgetting to turn off the unit.
Turns cooling off automatically after preset time elapses
Auto-offTimer
After adjusting the temperature for initialing on a hot day, it is easy to forget to return the temperature setting to its original value. The Auto-return function auto-matically resets the temperature back to the original setting after a specified period of time, thereby preventing overcooling. The Auto-return activation time can be set in 10-minute units, in a range between 30 and 120 minutes.*Auto-return cannot be used when Temperature Range Restrictions is in use.
Prevents wasteful operation byautomatically returning to the preset temperature after specified operating time
Auto-return
This function monitors the room temperature and automatically activates the cooling mode when the temperature rises above the preset maximum tempera-ture setting.
Keep desired room temperaturesautomatically
NightSetback
Choose the desired language, among the following languages.
Multi-Ianguage
Full Dot Liquid-crystal Display Adopted
[English] [Italian] [German][Spanish] [Swedish] [Russian] [Portuguese][French]
Cooling/Dry (Setting example of minimum temp. in 25C)
Lower temperature limit
Possible temperature range setting
19(C) 30(C)
30(C)25(C)
To prevent excessive coolingLower temperatures cannotbe selected
Meeting room Changing roomRecommended for
In addition to operation start/stop, the operation mode, temperature setting and air-flow direction can be locked. Unwanted adjustment of temperature settings is pre-vented and an appropriate temperature is constantly maintained, leading to energy savings. This feature is also useful in preventing erroneous operation or tampering.
Fixed temperature setting promotesenergy savings
OperationLock
The Weekly Timer enables the setting of operation start and finish times and adjust-ing the temperature as standard features. Up to 8 patterns per day can be set, pro-viding operation that matches the varying conditions of each period, such as the number of customers in the store.*Weekly Timer cannot be used when On/Off Timer is in use.
Set up to 8 patterns per day including temperature control
WeeklyTimer
Auto-descending panel operation is available as an option. Panels can be lowered/raised using a button on the wired remote controller. Filter cleaning can be performed easily.
Easily raise/lower panels using the remote controller
Auto-descending Panel Operation (4-way ceiling cassette)
Office Restaurant
Office Restaurant
Recommended for
PAR-31MAA
The adoption of dot liquid-crystal display (LCD) technology and a large display screen for the control panel optimises visibility. Op-eration and control status are easily read at a glance.
Energy-efficient Control
Operation Control Functions
Easy to Read/Easy to Use
Multi-language DisplayControl panel operation in eight different languages
Display Example [Operation Mode]
Dot LCD Choose the desired language, among the following languages.
Multi-Ianguage
Dot Liquid-crystal Display Adopted
PAR-21MAA
User-friendly Deluxe Remote Controller with Excellent
Operability and VisibilityPAR-21MAA
Advanced MA Remote Controller
A Progressive Step in the Evolution of Air Conditioning Control
Reassuring Troubleshooting Navigation Function
Contact Details Displayed When Abnormality Occurs Easily contact a service company when there is a problem.
The telephone number of a service company and other information can be input and stored in advance. When a problem occurs, the contact details are dis-played automatically, and a call for help can be made without delay.
Set the time for the air conditioner to turn off automatically. The timer can be set in the range from 30 minutes up to 4 hours in 30-minute intervals.The Simple Timerstarts/stops in units of 1 hour in a 72-hour periodis set at the time of shipment from the factory. It can be changed to the Auto-off Timer function using the remote controller.
Automatically turns offair conditioner
Auto-off Timer
Units can be set so that the operation mode cannot be changed. When Opera-tion Lock is activated, new temperature setting commands are not accepted, thereby ensuring that the unit runs in the specified (locked in) temperature range. This promotes energy savings and prevents erroneous/ mischievous operation.Only the administrator can change settings when using the Operation Lock mode.
Prevent operation settingsfrom being changed
Operation Lock
Set the upper and lower limits for the temperature range during operation. Exces-sive cooling is prevented, leading to increased energy savings.
Air conditioner operation restrictedto within a specified operating range
Temperature Range Restriction
Control temperature on a weekly basisTemperature settings and On/Off control can be managed over a period of one week using the Weekly Timer. Up to eight setting patterns per calendar day are possible.
Introduced in response tomarket demand
WeeklyTimer
[English] [Italian] [German][Spanish]
[Japanese] [Russian] [Chinese][French]
Cooling/Dry
Recommended for
Lower temperature limit
Possible temperature range setting
19(C) 30(C)
30(C)25(C)
To prevent excessive coolingLower temperatures cannotbe selected
(Setting example of minimum temp. in 25C)
Busyhours
Off-peakhours
4
26
25
24
23
22
0 10 12 14 16 18 20 22 24
Tem
per
atu
re s
etti
ng
(C
)
Opening time
Lunch time Dinner time
7-patterns setting
Closing time
Set to lower temperature Set to higher temperature
1
2
3 5
6 7
(Time)
(Results of cooperative study with Japan Facility Solutions, Inc.)
Meeting roomRecommended for Changing room
Recommended for
Computer server facility
Office School
Hospital
Public hall
Recommended for
Computer server facility
Office School
Hospital
Public hall
Setting Example (restaurant in summer time)
Busyhours
5
26
25
24
23
22
0 10 12 14 16 18 20 22 24
Tem
per
atu
re s
etti
ng
(C
)
Openingtime
Lunch time
Preparation
Dinner time
8-patterns setting
Closing time
Set to lower temperature Set to higher temperature1
2 4
3
6
7 8
(Time)*Joint research conducted with Japan Facility Solutions, Inc.
Off-peakhours
Setting Example (restaurant in summer time)
-
Ceiling-Concealed TypeModels
kWCMMCFM
kWBTU/h
Cooling capacity
Total input
Indoorunit
Outdoorunit
EERModel name
Fan motor output
Airflow(low-mid-high)
External static pressureOperation control & thermostatNoise level(low-mid-high)Unit drain pipe O.D.
Dimensions
WeightModel name SUY-KA18VA SUY-KA36VASUY-KA30VASUY-KA24VA
PEY-P18JA
425-510-600Pa
dB(A)mmmmmm
WD
12-14.5-17
5.3(2.8-5.4)18000
kW 1.57W/W 3.38
PEY-P18JA
620-740-88517.5-21-25
850-1025-120024-29-34
30-34-39 33-38-42
732
External finish Munsell 3.0Y 7.8/1.1Refrigerant (R410A) control Liner Expansion ValveCompressor output
Protection devices Discharge thermo, Comp.shell thermo, Over current protection, (Compressor)Over heat protection, Over current protection, (Fan motor)
mmH 250
46(1625)
kg
kW
1040-1225-148529.5-35.5-42
0.085 0.121
32
7
36-40-44
38
1.2
39
1400
0.244
30-35-39
1100900
2927
0.9
Fan motor output kW 0.060.05Airflow CMM(CFM) 51(1800)34(1200)
54 56Noise level
Dimensions
dB(A) 5851
47 50Weight kg 513315MAX.height difference m 1230MAX.piping length m 20
Liquid:9.52 Gas:15.88Pipe size O.D. mm Liquid:6.35 Gas:12.7Chargeless piping length m
W 840mm 800D 330mm 285H 880mm 550
Power SupplyExternal finish
PEY-P36JA10.6(4.1-10.7)
360003.333.18
PEY-P36JA
Gralvanized sheet
35-50-70-100-125Remote control & Built-in
PEY-P30JA8.8(4.1-9.7)
300002.5
3.52PEY-P30JA
PEY-P24JA7.1(3.6-8.9)
24000
3.51PEY-P24JA
2.02
1ph 220-240V 50Hz / 1ph 220V 60Hz
System Controls Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc.
Inverter Series 09-10SPECIFICATIONS
FOR INDOOR UNITS
2-remote Controller Control
With two remote controllers, control can be performed locally and remotely from two locations.
Operation Control by Level Signal
Air conditioner can be started/stopped remotely. In addition, On/Off operation by local remote controller can be prohibited/permitted.
Operation Control by Pulse Signal
Remote Display of Operating Status
Operating status can be displayed at a remote location.
Allows On/Off operation with timer*For control by an external
timer, refer to B Operation Control by Level Signal.
Timer Operation
Wired Remote ControllerPAR-31MAAPAR-21MAA
Wireless Remote ControllerPAR-SL97A-E (for PEY)
Wireless Remote Controller Kit for PCYPAR-SL94B-E
Adapter for remote On/Off PAC-SE55RA-E
Relay box (to be purchased locally) Remote control panel (to be purchased
locally)
Standard functions of PAR-31MAA
A
B
C
D
E
Details Major Optional Parts RequiredSystem Examples
Wired remote controller Wireless remote controller
Up to two remote controllers can be connected to one group.
Both wired and wireless remote controllers can be used in combination.
Operation other than On/Off (e.g., adjust-ment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.
Timer control is possible with an external timer.
Connector cable for remote display PAC-SA88HA-E / PAC-725AD(10 pcs. x PAC-SA88HA-E)
Relay box (to be purchased locally) Remote control panel (to be purchased
locally)
The pulse signal can be turned On/Off. Operation/emergency signal can be
received at a remote location.
Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RMno-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).
Weekly Timer:On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)
On/Off Timer:On/Off can be set once each within 72 hr. in intervals of 5-minute units.
Auto-off Timer:Operation will be switched off after a certain time elapse. Set time can be changed from30 min. to 4 hr. at 10 min. intervals. *Simple Timer and Auto-off Timer cannot be used at the same time.
Remote display panel (to be purchased locally)
Connector cable for remote display PAC-SA88HA-E / PAC-725AD(10 pcs. x PAC-SA88HA-E)
Relay box (to be purchased locally) Remote operation adapter PAC-SF40RM *Unable to use with wireless remote controller
PAR-31MAAPAR-21MAA PAR-31MAA
PAR-21MAA
(Example of 1 : 1 system)
(Example of 1 : 1 system)
Relay box (to be purchased) locally)
Relay box (to be purchased) locally)
Adapter for remote On/Off
Adapter for remote On/Off
PAR-SL97A-E
PAR-SL97A-E
(Example of 1 : 1 system)
PAR-31MAA
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
* Set "Main" and "Sub" remote controllers. * When using wired and
wireless remote controllers
PAR-SL97A-E
Remote display panel
Remote display panelPAR-31/
21MAA
Remote control panel
Remote control panelWired remote
controller
Connector cable for remote display
Connector cable for remote display
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
(Example of 1 : 1 system x 2)
Remote control panel
Remote control panelWired remote
controller
Remote operation adapter/Connector cable for remote display + Relay box
Remote operation adapter/Connector cable for remote display + Relay box
MAJOR SYSTEM CONTROL
PAR-31MAA ControlPAR-21MAA Control
System Group Control
M-NET Connections
PAR-31MAA (Wired remote controller) PAR-21MAA (Wired remote controller)
MAC-333IF-E (Interface) PAR-31MAA (Wired remote controller) PAR-21MAA (Wired remote controller)
A
B
C
Details Major Optional Parts Required
System Examples
PLY,PCY,PEY Series Indoor Unit
SUY Series Outdoor
Indoor Unit
Outdoor Unit
Standard equipment (for indoor units compatible with wired remote controllers)
One remote controller can control plural air conditioners with the same settings simultaneously.
One remote controller can control up to 16 refrigerant systems.
Up to two remote controller can be connected.
MAC-333IF-E MELANS System controller PAC-SC51KUA (power supply unit)
Group of air conditioners can be controlled by MELANS system controller (M-NET).
PAR-31MAAPAR-21MAA
MAC-333IF-E
Outdoorunit
Indoor unit
MAC-333IF-E MELANSsystem controller(AG-150A etc)
PAC-SC51KUAPower supplyunit
City Multi indoor unit
Outdoorunit
Indoor unit
PAR-31MAAPAR-21MAA
PAR-31MAAPAR-21MAA
PAR-31MAAPAR-21MAA
Ceiling-Suspended TypeModels
kWCMMCFM
kWBTU/h
Cooling capacity
Total input
Indoorunit
Outdoorunit
EERModel name
Fan motor output
Airflow(low-mid2-mid1-high)
External static pressureOperation control & thermostatNoise level(low-mid2-mid1-high)Unit drain pipe I.D.
Dimensions
WeightModel name SUY-KA18VA SUY-KA36VASUY-KA30VASUY-KA24VA
PCY-P18KA
0.095
565-600-635-705Pa
dB(A)mmmmmm
WD
16-17-18-20
5.3(2.8-5.4)18000
kW 1.51W/W 3.51
PCY-P18KA
565-635-705-77516-18-20-22
0.16
850-920-990-106024-26-28-30
34-36-40-42 39-41-43-45
680
External finish Munsell 3.0Y 7.8/1.1Refrigerant (R410A) control Liner Expansion ValveCompressor output
Protection devices Discharge thermo, Comp.shell thermo, Over current protection, (Compressor)Over heat protection, Over current protection, (Fan motor)
mmH 230
46(1625)
kg
kW
32
955-1025-1130-120027-29-32-34
26
7
42-44-46-48
37
1.2
40
1280 1600
34-36-38-40
0.9
Fan motor output kW 0.060.05Airflow CMM(CFM) 51(1800)34(1200)
54 56Noise level
Dimensions
dB(A) 5851
47 50Weight kg 513315MAX.height difference m 1230MAX.piping length m 20
Liquid:9.52 Gas:15.88Pipe size O.D. mm Liquid:6.35 Gas:12.7Chargeless piping length m
W 840mm 800D 330mm 285H 880mm 550
Power SupplyExternal finish
PCY-P36KA10.6(4.1-10.7)
360003.133.39
PCY-P36KA
Munsell 6.4Y 8.9/0.4
0 (direct blow)Remote control & Built-in
PCY-P30KA8.8(4.1-9.7)
300002.6
3.38PCY-P30KA
PCY-P24KA7.1(3.6-8.9)
24000
3.38PCY-P24KA
2.1
1ph 220-240V 50Hz / 1ph 220V 60Hz
Ceiling Cassette TypeModels
kWCMMCFM
kWBTU/h
Cooling capacity
Total input
Indoorunit
Outdoorunit
EERModel name
Fan motor output
Airflow(low-mid2-mid1-high)
External static pressureOperation control & thermostatNoise level(low-mid2-mid1-high)Unit drain pipe O.D.
Dimensions
Weight ( ):Panel
( ):Panel
Model name SUY-KA18VA SUY-KA36VA SUY-KA30VASUY-KA24VA
PLY-P18BA
425-460-495-565Pa
dB(A)mmmmmm
WD
12-13-14-16
5.3(2.8-5.4)18000
kW 1.47W/W 3.61
PLY-P18BA
495-565-635-70514-16-18-20
705-775-885-99020-22-25-28
28-30-32-34 33-35-38-41
840(950)840(950)
External finish Munsell 3.0Y 7.8/1.1Refrigerant (R410A) control Liner Expansion ValveCompressor output
Protection devices Discharge thermo, Comp.shell thermo, Over current protection, (Compressor)Over heat protection, Over current protection, (Fan motor)
mmH
46(1625)
kg
kW
850-920-1025-113024-26-29-32
0.05
32
7
37-39-41-44
24(6)
1.2
26(6)
0.12
258(35) 298(35)
28-29-30-32
22(6)19(6)
0.9
Fan motor output kW 0.060.05Airflow CMM(CFM) 51(1800)34(1200)
54 56Noise level
Dimensions
dB(A) 5851
47 50Weight kg 513315MAX.height difference m 1230MAX.piping length m 20
Liquid:9.52 Gas:15.88Pipe size O.D. mm Liquid:6.35 Gas:12.7Chargeless piping length m
W 840mm 800D 330mm 285H 880mm 550
Power SupplyExternal finish
PLY-P36BA10.6(4.1-10.7)
360003.133.39
PLY-P36BA
Munsell 6.4Y 8.9/0.4
0 (direct blow)Remote control & Built-in
PLY-P30BA8.8(4.1-9.7)
300002.363.73
PLY-P30BA
PLY-P24BA7.1(3.6-8.9)
24000
3.51PLY-P24BA
2.02
1ph 220-240V 50Hz / 1ph 220V 60Hz
-
Inverter Series 11-12EXTERNAL DIMENSIONS
Unit : mm
10
69
800
302.5
500 Bolt pitch for installation
150
22.3
Handle
550
280
164.
5
99.5 170.5
23Service panel
Service port
285
344.
5 44
400Air in
Air out
Air in
17.5
Bol
t pitc
h fo
rin
stal
latio
n30
4~32
5
40
Liquid refrigerant pipe joint
Gas refrigerant pipe joint
4335
2 holes 10X21
Drain hole
SUY-KA18VAOUTDOOR UNIT
SUY-KA24VA SUY-KA30VA SUY-KA36VAOUTDOOR UNIT
417.5
4042Drain hole
175 500
330 5
0
Air in
Air out2-holes 10 21
360
840109
81
880
452
Service panel
99.5
164.
5
195
35
44
Liquid refrigerantpipe joint
Gas refrigerantpipe joint
42
Bol
t pitc
h fo
rin
stal
latio
n
Air in
Unit : mm
Ceiling hole
Branch duct hole
Indoor unit/Outdoor unit connecting terminal block Indoor power supplyterminal block(optional part)
Branch duct hole
Fresh air intake hole
Ceilin
g ho
le
Susp
ensio
n bo
lt pitc
hSuspension bolt pitch
Remote controller terminal block
(7.5)
(7.5)
605
+35
-
5
620
160
160
160
840
150
90 C D
840187.5
20~45 860~910 20~45
810
20~4
586
0~91
020
~45
24 160
950
Cut out hole
Cut out hole
Burring hole pitch Burring hole175
167
130
100
70
155
350
90 100 100 90
Detail connecting of branch duct
14- 2.8150
37728460 Drain pipe
Ceiling
Grille
Power supply wire,Indoor unit/Outdoor unit connecting wire entryControl wire entry Keep approximately
10 to 15mm spacebetween unit ceiling and ceiling slab.
Suspension bolt M10 or W3/8
A17
+5 0
B35
190
156
105
140
50~7
0Suspension bolt lower edge
170
Models BA C D
241 25880
85
74
29877
281
PLY-P18BAPLY-P24BAPLY-P30BAPLY-P36BA
PLY-P18BA PLY-P24BA PLY-P30BA PLY-P36BAINDOOR UNIT
950
Refrigerant pipe
Refrigerant pipe
(liquid)
(gas)
INDOOR UNIT
When drain socket is installed(Drainage)
(
PCY-P30KA PCY-P36KA
233
510
51
246
180200
236
8488
195 230
5725
447
668
0
182 851518
1600 221493
Air outlet
Air intake
(gas)(liquid)
PCY-P18KA PCY-P24KA
INDOOR UNIT
Air intake
Air outlet
8488
195 230
57
254
476
680
182 85
1198
1280 221173
When drain socket is installed
233
5
10
51
246
A
B
236
(Drainage)
(gas)
(liquid)
((
PEY-P18JA PEY-P24JA PEY-P30JA PEY-P36JA INDOOR UNIT
Models
PEY-P30JAPEY-P36JA
PEY-P24JAPEY-P18JA
A900
11001400
954B
11541454
860D
10601360
9E
1114
1200
C
1500
1000
13001000
F800
13581058
G858
Models
PCY-P24KAPCY-P18KA
A184180
203B
200
5778
250
3312
2
15
24
5710
100
100x
(E-1
)=F
AB
(Sus
pens
ion
bolt
pitc
h) C
23
643(Suspension bolt pitch)
30
20D
(Duc
t)17
8(D
uct)
4023
1032 700
732
136 67356
100
217
Suspension bolt hole 4-14x30 Slot
Airoutlet
Airinlet
Refrigerant piping Flare connection(liquid)
Refrigerant piping Flare connection(gas)
Control box
Terminal block (Indoor/Outdoorconnecting line)
Terminal block (Remote controllertransmission line)
2xE- 2.9
2x2- 2.9
Drain pipe(O.D. 32)
-
Inverter Series 13-14
SUY-KA
Upper limit (DB)
Lower limit (DB)
46C
18C
Cooling
Guaranteed Operating Range
Sound Pressure Level Sound pressure measurements were conducted in an anechoic chamber.
The actual noise level depends on the distance from the unit and the acoustic environment.
Single-phase, 220-240VSingle-phase, 220-240V50Hz
Single-phase, 220VSingle-phase, 220V60Hz
Notes for All Specifications
Rating conditionsCooling - Indoor: 27C (80F) DB, 19C (66F) WB Outdoor: 35C (95F) DB
Refrigerant piping length (one-way): 7.5m (25ft.)
Total input based on the indicated voltage (indoor/outdoor)
Indoor Outdoor
Refrigerant Piping
SUY-KA18
SUY-KA24
12
15
20
30
SUY-KA30
SUY-KA36
15
15
30
30
Liquid: 9.52
Gas: 15.88
Liquid: 9.52
Gas: 12.7
Liquid: 6.35
Gas: 15.88
Liquid: 9.52
Gas: 15.88
t 0.8
t 1.0
t 0.8
t 0.8
t 0.8
t 1.0
t 0.8
t 1.0
Thickness (mm)Pipe size OD (mm)CapacityBetween indoor & outdoor units
Max. height difference (m) Max. piping length (m)
Amount of Necessary Refrigerant (R410A: kg)
SUY-KA18
SUY-KA24
SUY-KA30
SUY-KA36
1.2
2.0
2.1
2.5
0.05
0.06
0.06
0.06
0.12
0.16
0.16
0.16
0.2
0.26
0.26
0.26
0.36
0.36
0.36
0.36
0.46
0.46
Xg = 15g/m (length-7)m
Xg = 20g/m (length-7)m
30m25m20m15m10m7m
Factory charged Additional charged
CalculationPiping length
NOTICE
Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction.
When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.Do not mix it with any other refrigerant and do not allow air to remain in the lines.If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
Outdoor Unit Installation Location
A
D
C
A
B
A
C
A
C
B
SUY-KA18VA SUY-KA24VASUY-KA30VASUY-KA36VA
Outdoor unitVentilation and service space
100 mm or more 350 mm or moreBasically open 100 mm or more without any obstruction in front and both sides of the unit.200 mm or more (Open two sides of left, eight, or rear side.)
SUY-KA18VAA B
100 mm or more 350 mm or more 500 mm or more SUY-KA24VA SUY-KA30VA SUY-KA36VA
A B C
C
D
When the piping is to be attached to a wall containing metals (tin plated) or metal netting, use a chemically treated wooden piece 20mm or thicker between the wall and the piping or wrap 7 to 8 tums of insulation vinyl tape around the piping.
Units should be installed by licensed contractor accordingly to local code requirement.
Optional Parts
Part name Model name Application name
PCY-P24/30/36PAC-SH84DM-E
PCY-P18PAC-SH85DM-E
PLY-PPAC-SH65OF-EFlange for fresh-air intake
Drain pump
All indoor unitsMAC-333IF-E
PLY-P / PEY-PPAR-SL97A-E
M-NET&Terminal interface
Wireless remote controller
PEY-PPAR-SA9CA-EWireless remote controllersignal receiver PLY-PPAR-SA9FA-E
PCY-P18/24PAC-SH89KF-E
PCY-P30/36PAC-SH90KF-E
PLY-PPAC-SH59KF-E
PEY-P18PAC-KE92TB-E
High efficiency filter element
Filter box PEY-P24PAC-KE93TB-E
PEY-P30/36PAC-KE94TB-E
PLY-PPAC-SA1ME-E
PLY-PPAC-SH51SP-E
i-see sensor corner panel
Shutter plate
PLY-PPAC-SH53TM-EMulti-function casement
All indoor unitsPAC-SE55RA-ERemote On/Off adaptor
All indoor unitsPAC-SF40RM-ERemote operation adaptor
All indoor unitsPAC-SE41TS-ERemote sensor
PLY-PPAC-SH48AS-ESpace panel
All indoor unitsPAC-SA88HA-EConnector cable for remote display
Wired remote controller
Air discharge guide
Multiple remote controller adaptor
All indoor unitsPAR-31MAA
All indoor unitsPAR-21MAA
SUY-KA18MAC-881SG
SUY-KA24/30/36MAC-886SG
PCY-PPAR-SL94B-EWireless remote controller kit(Sender & Receiver)
PAC-725AD All indoor units
High efficiency filter