MSS 15-240 Installation Operation Manual, 02-015-XXXXXX-0
INSTALLATION & OPERATION MANUAL
www.fedco-usa.comONE COPY OF THIS MANUAL MUST REMAIN WITH THE EQUIPMENT AT ALL TIMES
English Version
Models: MSS-15 ● MSS-20 ● MSS-30 ● MSS-40 ● MSS-50 ● MSS-55MSS-55 ● MSS-70 ● MSS-75 ● MSS-90 ● MSS-120
MSS-160 ● MSS-200 ● MSS-240
MSS™MULTI-STAGE SEAWATERHIGH PRESSURE PUMPS
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 2 -
FEDCO CertificationsISO 9001 and ISO 14001:
FEDCO has adopted the ISO 9001 standard to define and develop our Quality Manage-ment System (QMS.) The QMS allows FEDCO to better serve our customers’ needs through continuous improvement of the quality, delivery, and efficiency of our products.
3 FEDCO achieved ISO 9001 registration in September 2017.
FEDCO has adopted the ISO 14001 standard to define and develop our Environmental Management System (EMS) to better protect our environment.
3 FEDCO achieved ISO 14001 registration in September 2017.
CE Stamp:
CE marking confirms that specific products are in compliance with European Union requirements. This allows FEDCO’s product lines to be sold throughout the European Economic Area. Most FEDCO products can be provided with the CE mark.
Compliant Test Systems:
Performance acceptance testing of FEDCO pumps and energy recovery devices are measured using procedures and instrumentation tested by a third party NSF® auditing company to be in accordance to the Hydraulic Institute’s H.I. 14.6 standards for cen-trifugal pump testing and data recording.
www.fedco-usa.com
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 3 -
Commitment to Quality & SuccessFluid Equipment Development Company (FEDCO) was founded in 1997 to develop new fluid machinery to reduce the cost of reverse osmosis desalination. The results included patented concepts, highly in-tegrated design, superior production software, and sophisticated manufacturing processes. Our efforts culminated in multiple lines of energy recovery tur-bines and pumps uniquely suited for seawater and brackish RO desalination. We are the developers of the HP-HEMI™ ERD and control system for mega-scale SWRO systems, as well as the world’s first low-cost integrated pump-ERD for brackish water RO. Additionally, our Monroe facility operates the largest pump and ERD test system dedi-cated to SWRO systems in the world. Our teams of talented and energetic engineers, manufacturing specialists and systems experts have created a fully integrated enterprise with one aim – to provide our customers with customized fluid machines with exceptional efficiency and low capital cost cou-pled with customer service that exceeds their expec-tations. The results include new designs, technology, manufacturing processes, and standards. Our pumps and ERDs use bearings that are lubricated by feed or brine to eliminate the numerous maintenance and lo-gistics issues associated with oil or grease lubricated bearing systems. We offer three materials of construc-tion: Duplex SS, Super Duplex SS and 316 SS.
We design fluid machines to take full advantage of the technical characteristics of the membrane process.
FEDCO pumps only cover flows and pressures found in BWRO and seawater SWRO applications. They are designed for clean fluids and are optimized for typical suction pressures in RO systems. Our ERDs include variable area nozzles that meet typical brine pressure variations. Our products eliminate external tubing car-rying high pressure feed or brine that can fail creating hazards to personnel and equipment. Our units are designed for operation and maintenance by unskilled personnel in the harshest of desert or marine environ-ments.
With the longest warranty and the highest efficiencies, our product lines are unmatched in quality and per-formance by any manufacturer in the RO equipment market. FEDCO is a widely recognized supplier with thousands of units installed around the world.
Eli Oklejas - FEDCO CEO
FEDCO USAFEDCO
800 Ternes DriveMonroe, MI 48162, USA
Telephone: +1 (734) 241-3935 Fax: 734-241-5173
Email: [email protected]
FEDCO DUBAI Technopark, Plot TP10501
Jebel Ali South, PO Box 37603, Dubai, UAE
Telephone: +971-(0)4 880 7344Mobile: 917-055-774-9805
Email: [email protected]
FEDCO SINGAPORE Singapore Branch
82 Toh Guan Road East#C2-14-4 WaterHub Singapore, 608576
Telephone: +(65) 6779 0123Email: [email protected]
www.fedco-usa.comFor patent coverage visit patent.fedco-usa.com
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 4 -
Table of ContentsUnpacking/ Inspection/ and Storage ...........5
MSS External Components......................... 5Inspection of Unit Upon Receipt ................. 5Pump Storage Requirements ..................... 6Motor Storage Requirements ...................... 6Pre-Installation ............................................ 6
Theory and Operation ...................................7Technical Description .................................. 7MSS Pump Internal Components ............... 8
Installation Procedures .................................9Warnings and Safety Precautions ............... 9User Health and Safety ............................. 10In the Work Area ....................................... 10Electrical Connections and Regulations ... 10Variable Frequency Drive (VFD) Requirements ........................................... 11Motor and Pump Installation Requirements 11Lifting and Handling .................................. 12Pump Assembly Lifting ............................. 12Motor and Pump Assembly Lifting ............ 13Optional Baseplate Installation ................. 14Foundation Specifications ......................... 15
Pump Assembly ...........................................16Motor Installation....................................... 16Initial Pump Alignment .............................. 20Final Pump Alignment ............................... 24Pump Piping Connections......................... 29Optional High Pressure Seal Carrier......... 31Optional Shaft Position Sensor ................. 31Recommended Instrumentation and Operation .................................................. 32
Upstream Filtration ......................................33Preparation For Pump Start Up ..................33
Start Up Precautions ................................. 33Start Up Check List ................................... 33
Pump Start Up ..............................................33Basic Troubleshooting ................................34
Visual Inspection ....................................... 34Basic Troubleshooting Chart .....................35Specifications ..............................................36
Recommended Spare Parts List ............... 36Service Parts Kits...................................... 36Fastener Torque Specifications ................ 41Pump Alignment Specifications ................ 41Balance Disc Specifications ...................... 41Lubricants and Compounds ...................... 41Maintenance Schedule ............................. 42
Service Policy ..............................................43Return Material Authorization (RMA) ....... 43Procedure ................................................. 43Start-Up Record ....................................... 44Overhaul Record ....................................... 45
Warranty Registration Form .......................46MSS Unit Operating Conditions .................47Notes.............................................................47
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 5 -
Unpacking/ Inspection/ and StorageMSS External Components
Inspection of Unit Upon Receipt• Review the contents of the packing list to make sure all components have been included. • Inspect all components for signs of damage which may have occurred during shipping. • If damage is present or if the contents are incomplete, please contact your shipping company
or a FEDCO representative before proceeding.
1 2 3
4
5
67
8
9
10 11
12
13
14
15
16
17
18192021
22
2324
25
26
Figure 1 - Pump Assembly External Components
Item Description Item Description1 Precision leveling foot 14 Series shell (if equipped)2 Shell support bracket 15 Series shell O-ring (if equipped)3 Inlet housing bolts 16 Shell flange bolts4 Inlet housing O-ring 17 End shell5 Inlet housing 18 Discharge housing O-ring6 High pressure seal carrier O-ring (if equipped) 19 Discharge housing7 High pressure seal carrier (if equipped) 20 Discharge housing retaining ring8 Shipping plug 21 Retaining clips9 Coupling guard screws (part of coupling guard) 22 Retaining clip cap screws10 Coupling guard 23 Lock washer11 Motor adapter 24 Throttle nipple12 Motor adapter bolts 25 Throttle nipple O-ring13 Flexible coupling 26 Bearing drain line
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 6 -
Feeler Guages
2 Alignment Pins
Anit-seize compound
ANTI-SEIZE
4 to 8 Motor adapter bolts with washers
2 Flexible coupling set screws
Pump shaft key
Flexible coupling
4 to 6 Motor mounting bolts with washers and nuts (if motor and baseplate is provided by FEDCO)
Motor shaft key (if motor is provided by FEDCO)
(Supplied unless motor is metric)
Figure 2 - Installation Accessories
Unpacking/ Inspection/ and Storage Continued
Pump Storage Requirements • The MSS unit must be protected from
moisture, sand, grit, and other foreign mat-ter. Do not remove the protective covers from the pipe connections until ready to in-stall. For long-term storage, keep pump and all other components in its original crate away from moisture, sand or dust.
Long-Term Storage (>6 Months) Checklist1. Check caps to ensure they have not been damaged or allowed debris inside the unit.• Check for debris (wood, slag, sand or any dirt) and clean up with a clean, wet rag if minor.2. Shaft Check:• Turn manually and check for ease of turning or rubbing.• Check for axial movement.3. Seal Check:• Prime MSS with clean water and allow theO-rings to soak for 1 hr before start-up.Check for leaks.
Motor Storage Requirements• Specific conditions are required for proper motor care and storage. Refer to the motor manu-
facturers instructions for specific steps and instructions.
Pre-Installation• All necessary installation accessories will be included with the pump.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 7 -
Theory and Operation
Technical Description
Multi-stage seawater (MSS) pumps are centrifugal feed pumps specifically designed for seawater reverse osmosis (SWRO) service. MSS pumps develop pressure by using a series of impellers mounted on a rotating shaft. Rotating this fluid through centrifugal force develops a pressure higher than the input pressure. Pres-sure can be increased through the addition of impeller stages or by increasing shaft rpm. Motors are selected according to equipment
operating requirements. A flexible coupling al-lows the pump shaft to float within the coupling eliminating thrust against the motor. The inlet and discharge housing is designed to connect to grooved rigid piping with couplings. The inlet housing itself can be attached to the pump in four different positions 90° apart. A precision leveling foot supports the end shell housing and is fully adjustable to allow accurate pump to motor shaft alignment.
1
2
3
4
456
7
8 9 1011
12
Figure 3 - MSS Pump External Components
Item Description Item Description1 Motor 7 Throttle nipple2 Motor adapter 8 Discharge housing3 Flexible coupling (inside of motor adapter) 9 Top cradle4 Support bracket 10 End shell housing5 Bearing drain line 11 Series Shell housing (if equipped)6 Precision leveling foot 12 Inlet housing
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 8 -
Theory and Operation Continued
MSS Pump Internal Components
The internal components of an MSS pump can vary depending on pump configuration and number of stages. The basic components contained in a single stage consist of an impeller and a diffuser with a spacer and bushing which prevent friction and wear.
Behind the discharge housing at the end of the pump is the WATER BEARING™ assembly. The balance disc rides in the bearing carrier and serves as a thrust bearing for the pump. This unique design uses patented WATER BEARING™ technology which allows feed water to cool and lubri-cate the balance disc. As the motor rotates the pump, pressure differences acting on the rotating impellers generate an axial thrust acting toward the motor. The water bearing employs the bal-ance disc to create a counter-pressure which exactly cancels the impeller thrust load. The bear-ing drain line and throttle nipple are used help produce the counter-pressure on the balance disc. This thrust and counter-thrust allows the disc to “self-balance” based on operating conditions.
INLET PRESSURE
DISCHARGEPRESSURE
WATER BEARING™ASSEMBLY SINGLE
STAGE
Figure 4 - MSS Pump Internal Flow
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 9 -
Hazards which are NOT IMMEDIATELY ACCESSIBLE and can RESULT IN SEVERE PERSONAL INJURY OR DEATH if instruc-tions are not followed properly.
Hazards which are related to Electrical Components and can RESULT IN ELECTRICAL RISKS, SHOCK, ELECTROCUTION OR DEATH if instructions are not followed properly.
Hazards which are NOT IMMEDIATELY ACCESSIBLE, and can cause PERSONAL INJURY.
Hazards which are NOT IMMEDIATELY ACCESSIBLE, but are capable of causing SEVERE PERSONAL INJURY OR DEATH.
Hazards which are IMMEDIATELY ACCESSIBLE, and capable of causing SEVERE PERSONAL INJURY OR DEATH.
DANGER
WARNING
CAUTION
ELECTRICAL HAZARD
PUNCTURE HAZARD
Installation ProceduresWarnings and Safety Precautions
Safety practices and precautions for the opera-tion and maintenance of all FEDCO pump products MUST BE FOLLOWED. This information supple-ments oral or written instructions that may be re-ceived. Safety MUST be practiced as part of the standard operating procedures for this equipment during any installation and operation. To ensure that safe operating and maintenance procedures are fol-lowed, operators should develop and keep up a pro-gram of safety checks and current instructions. This manual contains certain operating and maintenance procedures that involve exposure to potentially haz-ardous situations. The levels of hazardous situations are as follows:
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 10 -
Installation Procedures Continued
WARNING
All pump and safety precautions must be followed to prevent physical injury to the operator. It is illegal to operate the equipment in an EU member state if the manual(s) is not written in that states language. Contact FEDCO if a translated copy is needed.
CAUTION
A pump is a pressure-generating device with rotating parts that can be hazardous. Any device containing generated pressure can rupture, explode or dis-charge its contents if it is over-pressurized and may possibly result in personal injury, property damage, environmental damage and death. All necessary precautions must be exercised to insure over-pres-surization does not occur. FEDCO will not accept responsibility for physical injury, damage or delays caused by a failure to observe the instructions in this manual.
WARNING
Installation, operation or maintenance of the pump unit in any manner which is not covered in this manual could cause damage to the equipment, seri-ous injury or death. This includes any modification to the equipment or the use of parts not provided by FEDCO. If there is a question regarding the intend-ed use of the equipment, please contact a FEDCO representative before proceeding.
CAUTION
This manual clearly identifies accepted methods for safe disassembly and assembly. These methods must be strictly adhered to.
WARNING
Do not use the pump equipment for a different appli-cation than originally specified without the approval of a FEDCO representative.
WARNING
NEVER operate the pump equipment:● below the minimum flow rate.● when dry.● without priming.● without proper guards and safety devices installed.● with the discharge valve closed.● with the suction valve closed.
WARNING
FEDCO pumps are intended to pump saltwater and brine to membranes for the reverse osmo-sis desalination process. FEDCO pumps are not intended to pump flammable or hazardous liquids. Solutions intended for human consumption need proper purification per product. FEDCO approval will be needed to control slurry and particle size for this specific product
ELECTRICAL HAZARD
Always follow the Lock-out / Tag-out procedure developed by your company before starting any maintenance or repair.
Figure 5 - Typical Lock-Out Tag-Out TagUser Health and SafetySafety equipment and PPE (Personal Protection Equipment) should be used in accordance with company regulations.
In the Work Area• Always keep the work area clean and dry.• Avoid all electrical dangers. Be aware of risks
from electric shock or arc flash hazards.• Utilize adequate lifting equipment and
methods.
Electrical Connections and Regulations• Refer to the motor nameplate for specific
electrical operating information.• Electrical connections must be made by
certified electricians in compliance with all international, national, state, and local regulations and codes.
• Insure the product is isolated from the power supply and cannot be accidentally energized.
• Make sure all thermal contacts are connected to a protection circuit according to product specifications.
• All electrical equipment must be properly grounded.
• During installation, service and repair, the companies Lock out / Tag out Procedure must be followed.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 11 -
Installation Procedures Continued
Variable Frequency Drive (VFD) Requirements A VFD must be used to optimize the system to the best efficiency point (BEP) of the RO system. The VFD must be configured to match the motor nameplate information. The VFD does not come pre-programed. Please contact the equipment supplier if the VFD programming manual is not available. IN CE compliant countries the VFD must have a line filter which must be installed in the same metallic enclosure as the drive.
AC SINE WAVE POWER
VFD
VARIABLE FREQUENCY POWER
OPERATOR CONTROLS
6.13752
GIANT ®INDUSTRIAL MOTOR
CAT. NO.
SPEC.
HP
VOLTS
AMPS
R.P.M.
FRAME
SER. F.
NEMA NOM. EFF.
RATING
CC
BEARINGS
ENCL.
MFG. BY BALFOR ELECTRIC CO. U.S.A NP1256L
VM3559
35A13T123
3
208-230/460
8.1-7.6/3.8
3450
56C HZ 60 PH 3
1.15 CODE K DES B CLASS F
82.5 % P.F. 89 %
40C AMB-CONT
USABLE AT 208V 8.1 A
DE 6205 ODE 6203
TEFC SN FO603113416
Motor RequirementsELECTRICAL HAZARD
Wiring of the motor shall be completed in conformance with all local electrical codes. All EU countries must follow EN 60204-1. If a variable frequency drive (VFD) is provided with the motor, it is recommended that shielded cables are used between the VFD and the motor. The shield must be connected at both ends.
3-PHASEMOTOR PIGTAILS
GROUNDINGLUG
Figure 6 - Typical Motor Nameplate
Figure 7 - Typical Motor Electrical Connections
Motor and Pump Installation RequirementsA rigid mounting surface is required for pump-motor assemblies in order to prolong the life of critical components. Mounting surfaces con-structed of wood or other non-rigid materials are NOT acceptable as they may deflect during pump operation and cause shaft misalignment. All anchoring fasteners used should meet or exceed manufacturers specifications. All assemblies must be mounted on one of three types of substrates:• concrete foundation.• optional baseplate.• container with a suitable steel substructure.
Figure 8 - Basic VFD Configuration
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 12 -
Installation Procedures Continued
Lifting and Handling
CAUTIONObserve all lifting precautions. Failure to follow all lifting and handling precautions may result in serious injury! Unit weight is listed on the unit nameplate. Determine the weight of the unit to select an appropriate lifting method. If the weight of the pump exceeds manual lifting limits, me-chanical lifting equipment must be used. MSS pumps can be lifted by the shell using approved lifting straps together with suitable lifting equipment. The straps must be installed around the shell without disturbing the drain line. If straps are placed around the drain line, damage can oc-cur.
Pump Assembly Lifting
NO
Figure 9 - Improper Lifting Strap Positioning
YES
Figure 10 - Proper Lifting Strap Positioning
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 13 -
Installation Procedures Continued
CAUTIONWhenever possible, all components should be lifted and moved separately for safety. Do not lift the pump up by the shaft. If the unit is lifted by the shaft, damage may occur. Lifting and handling of the motor must be performed according manufacturers instructions. Do not lift the pump and motor by the motor eyebolt. The eyebolt is used for lifting the motor only.
Motor and Pump Assembly Lifting
NO
NO
YES
Figure 11 - Improper Motor and Pump Lifting Points
Figure 12 - Proper Motor and Pump Lifting
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 14 -
Installation Procedures Continued
Optional Baseplate InstallationSome units include an optional FEDCO baseplate which provides good mounting surfaces for the motor and pump. It also increases accuracy during the alignment process. Although the base-plate is precisely manufactured, it requires a solid foundation such as a concrete pad or rigid steel substructure. If the optional baseplate is used, it must be installed first to avoid distortion which may occur due to uneven floors or substructure. If the pump is installed within a container, it must be mounted on a rigid steel substructure that will not distort under the weight of the equip-ment or from torque reaction forces during pump operation.
1
23
4
Figure 13 - Optional Baseplate
Item Description Item Description1 Motor mounting (4 to 6 depending on motor) 3 Precision leveling foot mounting2 Support bracket mounting 4 Baseplate mounting feet
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 15 -
Figure 14 - Proper Shimming Uneven
Installation Procedures Continued
Foundation SpecificationsA concrete foundation is recommended for all MSS pump installations. Concrete provides good support and good vibration absorption. The foundation should have a mass that is 50% more than the total weight of the equipment and its perimeter should extend at least 6 inches (15 cm) on each side from the pump and motor. Make sure the concrete is completely dry and level be-fore installing any machinery. Make sure anchor bolts and shims are properly sized and installed in cases of uneven surfaces.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 16 -
Figure 15 - Placing Motor In Mounting Position Bolts
Pump Assembly
SOFT-FOOT
PROPERLYSHIMMED
NO
YES
Motor Installation1. Clean motor flange face with a clean cloth
to remove any foreign matter, rust or protec-tive coating and place motor in its mounting position.
2. Install motor mounting bolts and shims as necessary. Tighten to motor manufacturers specifications.
NOTES: Make sure to install shims where necessary to prevent motor frame distortion re-sulting from “soft-foot.” Soft-foot is a condition were one of the motor frame feet are not in flat contact with the mounting base. If not properly shimmed when the bolt is tightened, the motor frame will distort.
Figure 16 - Installing Motor Mounting Shims and Bolts
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 17 -
Figure 17 - Directional Arrows On Motor Adapter
Motor Rotational Direction Check3. Prior to pump installation energize motor to
determine direction of rotation. The correct rotation is indicated by arrows on pump mo-tor adapter. If rotation is incorrect, reverse polarity of motor wiring to change direction of rotation.
NOTES: Reversing polarity of VFD power input wires will not change motor rotational direction.
4. If motor rotational direction is correct, dis-connect power to motor according to lock-out/tag-out procedures and complete all electrical connections according to local codes and regulations.
Pump Assembly Continued
5. Loosen screws and remove coupling guards. This allows better access to view the cou-pling alignment.
Flexible Coupling Check
6. Slide flexible coupling over motor shaft with motor shaft key.
NOTES: If motor shaft key does not fit properly in the coupling keyway, lightly file motor shaft key until a proper fit is obtained.
Figure 18 - Removing Coupling Guards
Figure 19 - Installing Flexible Coupling On Motor Shaft
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 18 -
NO MOVEMENT
NO MOVEMENT
NO MOVEMENT
NO MOVEMENT
8. Slide flexible coupling over the pump shaft with pump shaft key.
NOTES: The rounded end of the key must be placed in the rounded end of the keyway.
Figure 21 - Installing Flexible Coupling On Pump Shaft
Figure 20 - Checking Flexible Coupling Fit On Motor Shaft
7. Inspect flexible coupling radial and axial fit. It should be tight with no visible radial move-ment and slide smoothly on and off the motor shaft.
Pump Assembly Continued
SMOOTH MOVEMENT
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 19 -
LITTLE OR NO MOVEMENT
LITTLE OR NO MOVEMENT
LITTLE OR NO MOVEMENT
LITTLE OR NO MOVEMENT
9. Inspect flexible coupling radial and axial fit. It should have little or no movement and slightly looser than the motor shaft fit. It should also slide smoothly on and off the pump shaft.
10. Once proper flexible coupling fit on both shafts has been obtained, remove the flex-ible coupling and proceed with Initial Pump Alignment.
NOTES: Flexible coupling will not be needed until Final Pump Alignment procedure.
Pump Assembly Continued
Figure 22 - Checking Flexible Coupling Fit On Pump Shaft
SMOOTH MOVEMENT
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 20 -
Pump Assembly Continued
2. Install alignment pins 180° apart into motor face.
NOTES: These are supplied unless motor is metric.
Initial Pump Alignment
1. Remove nuts and top cradle from precision leveling foot.
180° APART
Figure 25 - Alignment Pin Installation
Figure 24 - Removing Top Cradle
12
3
4
5
6
7
8
9
Figure 23 - Precision Leveling Foot Components
Item Description1 Top cradle2 Bottom cradle3 Threaded rod4 Jam nut5 Top nut6 Threaded rod nut7 Adjustment nut8 Jam nut9 Leveling foot frame
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 21 -
FEELER GUAGE
Figure 27 - Motor Adapter Gap Measurement Points
4. If a gap exists between the motor adapter and motor, use feeler gauges (provided) to measure the gap at 4 different points 90° apart.
NOTES: In some instances, there may be no gap between the motor and motor adapter.
Figure 26 - Positioning Pump Onto Alignment Pins
3. Carefully slide pump onto alignment pins and as close to the motor face as possible.
NOTES: Depending on the motor manufac-turer, a small gap may or may not be visible between the motor face and the pump adapter.
Pump Assembly Continued
MOTOR ADAPTER
MOTOR FLANGEFACE
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 22 -
NO
YES
A
BA=B
A≠B
A
B
AA
B B
6. Measure the motor adapter top and bottom gaps (A&B) and continue adjustment pro-cedures until the gap (if any) between the motor adapter and the motor is equal.
NOTES: This step is critical in properly align-ing the pump with the motor. All measurements must be the equal to ensure proper pump-to-motor shaft alignment.
NOTES: Acceptable motor adapter gap toler-ance specified in the Pump Alignment Specifi-cations section of this manual.
NOTES: Record the A & B measured alignment gap if existent in the Start Up Record section of this manual.
Figure 29 - Proper Top and Bottom Gap
Figure 28 - Precision Leveling Foot Adjustment
5. Align pump by adjusting the precision level-ing foot:
A. ADJUST TOP AND BOTTOM GAP - by ro-tating the adjustment nuts.
B. ADJUST RIGHT SIDE AND LEFT SIDE GAP - by loosening the precision leveling foot mounting bolts and moving precision leveling foot side to side.
Pump Assembly Continued
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 23 -
Figure 31 - Securing Precision Leveling Foot
8. Secure the precision leveling foot to foun-dation with bolts, washers and tighten to values specified in the Fastener Torque Specifications section of this manual.
NOTES: Do not secure the support brackets at this time.
Figure 30 - Proper Side-to-Side Gap
7. Measure motor adapter gap and continue adjustment until the gap between the motor adapter and the motor is the same on both sides (C&D).
NOTES: Acceptable motor adapter gap toler-ance specified in the Pump Alignment Specifi-cations section of this manual.
NOTES: Record the C & D measured align-ment gap if existent in the Start Up Record sec-tion of this manual.
NO
YESC=D
DC
C≠D
DC
Pump Assembly Continued
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 24 -
APPLY SYSTEM COMPLIANT ANTI-SEIZE COMPOUND
Figure 33 - Installing Motor Shaft Key
Final Pump Alignment1. Apply system compliant anti-seize com-
pound on motor shaft and install motor shaft key in shaft keyway.
30.5 cm(12” inches)
Figure 32 - Separating Pump From Motor
9. Carefully slide pump away from the motor and proceed to the Final Pump Alignment procedure.
NOTES: Make sure pump is well supported and slide pump far enough to provide sufficient room to install flexible coupling.
Pump Assembly Continued
1/8”
2. Position pump motor adapter against motor and verify gap between pump shaft and mo-tor shaft. Gap should be 1/8 of an inch.
3. Separate pump from motor and proceed with next step.
Figure 34 - Verify Gap
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 25 -
6. Apply system compliant anti-seize com-pound on pump shaft and install pump shaft key.
NOTES: The rounded end of the key must be placed in the rounded end of the keyway.
APPLY SYSTEM COMPLIANT ANTI-SEIZE COMPOUND
Figure 37 - Pump Shaft Key Installation
Figure 36 - Flexible Coupling Set Screw Locations
5. Install set screws and tighten to torque spec specified in the Fastener Torque Specifica-tions section of this manual.
NOTES: Set screws are only on the motor side of the flexible coupling. No set screws should be installed on the pump shaft side of the cou-pling.
Pump Assembly Continued
Figure 35 - Positioning Flexible Coupling On Motor Shaft
4. Slide the flexible coupling onto the motor shaft until the end of the motor shaft is flush with the end of the motor half of the flexible coupling.
NOTES: The motor shaft and its key should NOT be touching the plates of the flexible cou-pling disc pack. Ensure that the motor shaft key does not slide out of place or project past the end of the motor shaft.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 26 -
7. Rotate both shafts until the pump shaft key and the flexible coupling keyway are on top and aligned.
Figure 38 - Aligning Pump Shaft Keyway
9. Using feeler gauges, re-measure any gap between the motor adapter and motor at 4 different points 90° apart around the motor adapter.
NOTES: In some instances, there may be no gap between the motor and motor adapter.
NOTES: These values should be identical with the A, B, C, & D values found in the Start Up Record section of this manual.
FEELER GUAGE
Figure 40 - Motor Adapter Gap Measurement Points
Figure 39 - Position Pump For Final Alignment
8. Carefully slide pump against motor making sure the pump shaft key slides smoothly into the flexible coupling. Push pump by hand until motor adapter and motor are in contact.
NOTES: Make sure pump shaft key does not jam or fall out during installation.
Pump Assembly Continued
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 27 -
12. Install top cradle back to precision leveling foot. Tighten to torque spec specified in the Fastener Torque Specifications section of this manual.
Figure 43 - Installing Top Cradle
1 2
3
4
5
6
7
8
Figure 42 - Motor Adapter Torque Sequence
11. Install motor adapter bolts and washers. Tighten to torque spec specified in the Fas-tener Torque Specifications section of this manual.
NOTES: Tighten the motor adapter bolts in the sequence shown to minimize stress.
NOTES: Pump removed for clarity.
Pump Assembly Continued
AA
B B
Figure 41 - Precision Leveling Foot Adjustment
10. If uneven gaps exist, adjust the precision leveling foot as necessary until any gaps between motor and motor adapter are all the same. The gap variation should not ex-ceed the limits specified in the Pump Align-ment Specifications section of this manual.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 28 -
13. Install support bracket anchor bolts and washers. Tighten to torque spec specified in the Fastener Torque Specifications section of this manual (to specification for the size bolts used).
Figure 44 - Pump Support Bracket Anchor Bolts
Figure 46 - Coupling Guard Installation
Figure 45 - Pump Support Bracket Adjustment Bolts
15. Install coupling guards and tighten screws.
14. Adjust support bracket height and tighten adjustment bolts to torque spec specified in the Fastener Torque Specifications section of this manual.
Pump Assembly Continued
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 29 -
Pump Assembly ContinuedPump Piping Connections
Minimizing Excessive Loads/ Pipe Stress• Do not use the pump as an anchorage point
for the piping.• Anchor the pipelines in close proximity
to the pump and connect them without transmitting any stresses or strains.
• Take appropriate measures to compensate thermal expansion of the piping.
Piping Alignment• Accurate alignment and support of all piping
connected to the pump is critical.• Any movement occurring at the inlet
or discharge connections may cause misalignment and stress over time.
• Do not force any misaligned pipes to connect to the pump discharge or inlet.
Pipe Coupling Connections• Follow all manufacturer installation and
torque specifications.• Align all piping carefully before installing
couplings.• Make sure all seals seat correctly inside the
coupling.• If piping or seals are not aligned correctly,
leaking may occur under pressure.
Flanged Pipe Connections
Flanges Pipe Size (in.) Allowable Gap (in.)½ 0.018 ¾ 0.020 1 0.022 1 ½ 0.026 2 0.031 3 0.039 4 0.049 6 0.057 8 0.070 10 0.083 12 0.099
Figure 47 - Pipe Flange Fitting Allowable Gap
• Flange faces should be parallel 1/16 inch per foot diameter.
• Flange bolt holes should be aligned with a maximum offset of 1/8”
• Flange faces must be no more than a maximum of .5 degree from each other.
• Measure and record the flange gaps in the Start-Up Records section of this manual
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 30 -
YES NO
GROOVEDCOUPLING
COUPLINGSEAL
Inlet PipingKeep the inlet pipe free of high points which could trap air and could disrupt pump priming. Vac-uum and/or pressure gages are recommended to allow measurement of pump inlet pressure. NEVER throttle the pump on the inlet side.
Outlet PipingThe pump discharge piping should have a removable section of pipe such as a spool piece or elbow to allow the pump to slide forward for service. Servicing the shaft seal, water bearing or flexible coupling requires a space of approximately 30.5 cm (12 inches) minimum. The pump as-sembly must be free to move away from the motor in order to gain access to these components.
Figure 50 - Removable Section For Pump Service
Figure 49 - Typical Grooved CouplingFigure 48 - Proper Piping Alignment
30.5 cm (12 in)
REMOVABLE SECTION FOR PUMP SERVICE
DISCHARGE HOUSING
MINIMUM
OR
OUTLET PIPING
Pump Assembly Continued
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 31 -
Figure 52 - Shaft Position Sensor
SHAFT POSITIONSENSOR
ADJUSTMENT LOCKNUT
SPACER
Figure 51 - High Pressure Seal Carrier Venting
HIGH PRESSURE SEAL CARRIERVENT LINE
BEARINGDRAIN LINE
TO ATMOSPHERE OR MAXIMUM PRESSURE OF 100 psig
Pump Assembly Continued
Optional High Pressure Seal CarrierIf equipped with an optional high pressure seal carrier, a vent line from the HPSC should be vented to the atmosphere and positioned to drain normally or connected to a low pressure mani-fold behind the first high pressure pump in the train.
WARNINGUnder no circumstances should the vent line be plugged. A plugged vent line will result in insuf-ficient water lubrication of the seal and balance disc causing internal damage to the unit.
Optional Shaft Position SensorThe purpose of the shaft position sensor is to identify potential pump wear or failure before seri-ous damage can occur. The shaft position sensor is positioned directly above the position collar. If for any reason the shaft moves toward the motor, the collar moves out of range of the sensor shutting down the pump.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 32 -
Figure 54 - Pump Operating Specifications
Figure 53 - Recommended Instrumentation
PUMP INLET
PG 1 PS 1
PG 2
MSS PUMP
PG 3 PS 2
P
MEMBRANETHROTTLE VALVE (IF USED)
Pump Assembly Continued
Recommended Instrumentation and OperationFor safe pump operation, a pressure switch or relief valve is recommended for the high pressure side (before the membranes). Pressure gauges should be installed at the inlet and outlet of the MSS pump. If a throttle valve is used, an additional gauge is needed on the output side of the valve. It is recommended that a pressure switch should be installed at the pump inlet to prevent pump operation if the feed pressure to the pump is below specifications. MSS pumps are not equipped with a check valve to prevent back flow. Refer to the pump yellow tag and pump nameplate for equipment specifications.
Feed
Flo
w
XX
X gp
mIn
let P
res
XX
X ps
iD
isc. P
res
XX
X ps
iFe
ed S
G (c
alc)
XX
XXRP
M
XX
XXN
PSH
R
XXXX
Dut
y Po
int
Vers
ion
1.0
MSS
-XXX
XS/
N X
XXX
YELLOW TAG FRONT YELLOW TAG REAR PUMP NAMEPLATE
(copy tag information here)
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 33 -
Upstream Filtration• The pump must be protected from debris in
the feed water such as sand, gravel, or other particulate matter.
• A 20 micron filter must be installed upstream of the pump inlet to protect against foreign matter entering the system.
• Temporary strainers should be installed before initial start up or after repairs to protect the pump from possible debris.
Preparation For Pump Start UpStart Up Precautions
WARNINGNEVER operate the pump equipment:• below the minimum flow rate.• when dry.• without priming.• without proper guards and safety devices
installed.• with the discharge valve closed.• with the suction valve closed.
ELECTRICAL HAZARDRefer to the motor name plate, electrical junc-tion box cover, or wiring tag for proper wiring. All electrical connections should be made by a licensed electrician according to all local codes and regulations. Be sure to follow all manufac-turer’s instructions on motor lubrication. Ensure motor rotational direction is correct according to the arrow located on the motor adapter (Refer to Motor Rotational Direction Check).
CAUTIONElectric motors may develop continual noise over long periods. Proper ear protection should be worn during pump operation. Most noise will emanate from the electric motor. The noise level of the MSS pump is nominal and depends on its size and operating conditions. The typicallevel can range from 75dB to 85dB, measured at a distance of 1 meter (39 inches) around the pump. Sound may vary due to hydraulic reso-nance, valves and building walls. For applications were a minimum noise level is required, the sys-tem should be operated with the flow adjusted as close to optimum efficiency as possible. Vibration may also occur and varies based on pump size and operating conditions. As a reference, typical
vibration levels can reach .177” (4.5mm) per sec-ond RMS. See vibration test records or specifica-tions sheet for more information.
Start Up Check ListAn additional start up check list is available in the rear of this manual. Also use the Start Up Record at the rear of this manual to record initial operat-ing conditions at pump start up. □ Flexible coupling set screws tightened. □ Motor adapter guards installed. □ All anchor bolts tightened to specifications. □ All pipe couplings tightened to specifications. □ Motor rotational direction correct. □ Motor lubricated to manufacturers
specifications. □ Final Pump Alignment performed. □ Inlet pressure indicator installed. □ Inlet pressure switch (if applicable) installed. □ Outlet pressure indicator installed. □ System pipes are clean and upstream filtration in place. □ System leak checked and all air vented from system. □ ALL safety devices in place.
Pump Start UpNOTES: Use the Start Up Record located in the rear of this manual to record initial operating con-ditions at pump start up.
1. Start pump and vent air from the system.2. Verify that there are no leaks in the system.3. Activate the MSS pump.4. Inspect the system for leaks.
NOTES: Some mechanical seal leakage may occur for about 60 seconds after pump start-up. If the leakage continues longer than 60 seconds then proceed with the Mechanical Seal Replace-ment procedure located in the MSS Overhaul Manual.
5. Observe any unusual system noise or vibra-tion.
6. If a vibration meter is available, record a base-line vibration reading at this time. Note this vibration level in the Start-Up Records section of this manual.
7. Adjust system valves and controls as needed to obtain the desired operating condition.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 34 -
Basic Troubleshooting
If the MSS pump does not operate properly, refer to the following troubleshooting charts as a guide to determining the concern and identifying the potential cause. If after consulting the trouble-shooting charts the cause is still undefined, contact FEDCO technical support www.fedco-usa.com and choose the “Service and Support” tab, telephone or fax. FEDCO will give you easy, step by step instructions on how to proceed.
Visual Inspection• Make sure all items are accounted for on the start up check list.• Inspect all piping and electrical connections to the motor and pump.• Inspect the pump and motor mountings for signs of any movement or vibration.• Inspect pressure gauges, switches and all other instrumentation for proper operation.• Record any unusual readings.
Motor Speed and Direction Correct?
Inlet Piping Leaks?Motor Hooked Up Correctly
According to Manufactures Specs.
Pump Leaking?
Inlet Restrictions?
Discharge Restictions?
Air Vented From System?
Figure 55 - Basic Visual Inspection
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 35 -
Basic Troubleshooting ChartSymptom Possible Cause ActionLow flow or low pressure Restriction in inlet
or discharge pipes- Check pump inlet pressure- Check position of all control valves - Check throttle valve is fully open
Incorrect pump speed or direction
- Check VFD for proper speed setting (if equipped).- Check power supply frequency (50 or 60 Hz)- Check rotational direction of motor
Gauges not operat-ing properly
- Inspect gauges for proper operation.
Air leaks (vacuum on pump inlet)
- Inspect inlet piping joints for leaks- Inspect pump mechanical shaft seal for leaks
Pump cavitation - Check inlet pressure during operation- Check for excessive flow rate
Air in casing - Purge air from all piping
Internal damage - Damaged balance discDesign parameters - Pump not designed for operating conditions
Pump vibration or noise Operating condi-tions
- Pump cavitation- Excessive flow rate- Insufficient flow rate
Pump misalign-ment
- Inspect alignment (Refer to Final Pump Alignment)
Balance disc - Inspect balance disc for damage or wear
Pump leaks Pipe joints - Inspect pipe joints for insufficient sealing
Pump shell - Inspect pump shell for damaged O-rings
Pump shaft - Inspect mechanical seal for leakage- Inspect pump shaft for misalignment
Motor runs hot, is noisy or shuts off
Excessive motor load
- Check voltage supply for consistency- Check ambient air temperature - Check wiring and fuses for phase loss- Check flow rate and VFD settings (if equipped).- Check wiring length between motor and VFD (if equipped).- Check motor bearings
NOTES: Contact motor manufacturer for proper repair procedures.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 36 -
SpecificationsRecommended Spare Parts List
1-3 years of serviceRefer to Maintenance Schedule and Service Parts Kits chart on following 4 pages of this manual.
4-5 years of serviceA complete disassembly, cleaning and inspection of all pump components is recommended. An overhaul kit and stage kit should be made available before beginning this procedure. Refer to Maintenance Schedule and Service Parts Kits chart on following 4 pages of this manual.
Service Parts KitsRefer to Maintenance Schedule and Service Parts Kits chart on following 4 pages of this manual.
NOTES: Please provide pump serial number when ordering field service kits.
Ordering PartsTo order a component or service kit, simply contact a FEDCO representative at:
ATTN: Field Service Department Additional Contact Information:FEDCO Tel 734-241-3935800 Ternes Drive Fax 734-241-5173Monroe, MI 48162 Web site: www.fedco-usa.comUSA Choose the “Service and Support” tab
© C
opyr
ight
201
7 Fl
uid
Equ
ipm
ent D
evel
opm
ent C
ompa
ny |
ww
w.fe
dco-
usa.
com
- 37
-
MSS
-A S
ervi
ce P
arts
Kits
Com
pone
nts
Item
Part
Des
crip
tion
BD
KB
alan
ce D
isc
Kit
MSK
Mec
hani
cal
Sea
l Kit
MSK
HP
Mec
hani
cal
Sea
l Kit
HP
SC
OH
KO
verh
aul K
it
TNK
Thro
ttle
Nip
ple
Kit
TNK
HP
Thro
ttle
Nip
ple
Kit
HP
STG
Sta
ge K
itSH
TS
haft
Kit
OR
K
O-R
ing
Kit
OR
K H
P O
-Rin
g K
it H
P
RR
KR
etai
ning
R
ing
Kit
RR
K H
PR
etai
ning
Rin
g K
it H
P
FCK
Flex
C
oupl
ing
Kit
ALK
A
lignm
ent K
itD
LKD
rain
Lin
ke K
it
1S
hipp
ing
plug
*
2S
tatio
nary
sea
l ret
aini
ng ri
ngX
XX
3In
let w
ashe
rX
XX
4M
echa
nica
l sea
lX
XX
5M
echa
nica
l sea
l sha
ft w
ashe
rX
XX
6R
otat
ing
seal
reta
inin
g rin
gX
XX
X
7In
let O
-rin
gX
XX
X
8S
plit
colla
r ret
aini
ng ri
ng (M
SS
-15/
20/3
0/50
/70
only
)X
XX
X
9S
plit
colla
r (M
SS
-15/
20/3
0/50
/70
only
)X
10C
olla
r sle
eve
(MS
S-1
5/20
/30/
50/7
0 on
ly)
X
11In
let r
ing
*
12D
iffus
er b
earin
gX
X
13S
tage
spa
cer (
MS
S-1
5/20
/30/
50/7
0 on
ly)
XX
14D
iffus
er b
owl (
+ Fi
rst s
tage
hou
sing
for M
SS
-15/
20/3
0 on
ly)
XX
15Im
pelle
rX
X
16S
erie
s sp
acer
(MS
S-1
5/20
/30/
50/7
0 tw
o sh
ell p
umps
onl
y)X
X
17S
erie
s fla
nge
O-r
ing
XX
XX
18D
isch
arge
ring
*
19S
tage
spa
cer (
cust
om e
nd s
pace
r)X
20S
haft
was
her/
bala
nce
disc
was
her
XX
21B
earin
g ho
lder
*
22B
alan
ce d
isc
key
XX
23B
alan
ce d
isc
XX
24C
avity
cov
er O
-rin
gX
XX
X
25D
isch
arge
hou
sing
O-r
ing
XX
XX
26B
alan
ce d
isc
flatw
ashe
rX
X
27B
alan
ce d
isc
lock
was
her
XX
28B
alan
ce d
isc
nut
XX
29D
isch
arge
hou
sing
reta
inin
g rin
gX
XX
30P
ump
shaf
tX
31H
P sh
aft b
ushi
ng a
nti-r
oll p
inX
32H
P sh
aft b
ushi
ngX
33H
P sh
aft b
ushi
ng O
-rin
gX
X
34H
PS
C O
-rin
gX
X
35H
PS
C re
tain
ing
ring
XX
36A
ssem
bled
flex
cou
plin
gX
X
37S
haft
key
XX
38A
lignm
ent p
ins
X
39S
S s
him
set
X
40Th
rottl
e ni
pple
elb
owX
X
41Th
rottl
e ni
pple
XX
42Th
rottl
e ni
pple
O-r
ing
XX
XX
XX
43S
plit
cone
(MS
S-4
5/55
/75
only
)X
X
44S
plit
cone
nut
(MS
S-4
5/55
/75
only
)X
X
45C
lam
ping
nec
k rin
g (M
SS
-45/
55/7
5 on
ly)
XX
46Fl
oatin
g ne
ck ri
ng (M
SS
-45/
55/7
5 on
ly)
XX
47D
rain
line
elb
owX
48B
earin
g dr
ain
line
X
49D
rain
line
con
nect
orX
* Not
Incl
uded
in a
ny k
it. C
an b
e pu
rcha
sed
sepa
rate
ly.
© C
opyr
ight
201
7 Fl
uid
Equ
ipm
ent D
evel
opm
ent C
ompa
ny |
ww
w.fe
dco-
usa.
com
- 38
-
MSS
-A S
ervi
ce P
arts
Kits
Com
pone
nts
1
23
45
67
89
1011
1213
1415
1617
18
1920
21
2223
2425
26
2728
29
30
3132
3334
35
3637
38
39
40
41
42
47
48
49
Figu
re 5
6 - M
SS
-A S
ervi
ce P
arts
Kits
Com
pone
nts
15
14
12
43
4445
46
MSS
-40/
55/7
5
13
1215
14
14
MSS
-50/
70
© C
opyr
ight
201
7 Fl
uid
Equ
ipm
ent D
evel
opm
ent C
ompa
ny |
ww
w.fe
dco-
usa.
com
- 39
-
MSS
-B/C
Ser
vice
Par
ts K
its C
ompo
nent
sIte
mPa
rt D
escr
iptio
nB
DK
Bal
ance
Dis
c K
it
MSK
Mec
hani
cal
Sea
l Kit
MSK
HP
Mec
hani
cal
Sea
l Kit
HP
SC
OH
KO
verh
aul K
it
TNK
Thro
ttle
Nip
ple
Kit
TNK
HP
Thro
ttle
Nip
ple
Kit
HP
STG
Sta
ge K
itSH
TS
haft
Kit
OR
K
O-R
ing
Kit
OR
K H
PO
-Rin
g K
it H
P
RR
KR
etai
ning
R
ing
Kit
RR
K H
PR
etai
ning
Rin
g K
it H
P
FCK
Flex
C
oupl
ing
Kit
ALK
A
lignm
ent K
itD
LK
Dra
in L
ine
Kit
1S
hipp
ing
plug
*
2S
tatio
nary
sea
l ret
aini
ng ri
ngX
XX
3In
let w
ashe
rX
XX
4M
echa
nica
l sea
lX
XX
5M
echa
nica
l sea
l sha
ft w
ashe
rX
XX
6R
otat
ing
seal
reta
inin
g rin
gX
XX
X
7In
let O
-rin
gX
XX
8C
lam
ping
nec
k rin
g (M
SS
-90/
120
size
onl
y)X
X
9Fl
oatin
g ne
ck ri
ng/ d
iffus
er w
ear r
ing
XX
10D
iffus
er b
earin
gX
X
11D
iffus
erX
X
12S
plit
cone
XX
13Im
pelle
rX
X
14S
plit
cone
nut
XX
15S
erie
s fla
nge
O-r
ing
XX
XX
16B
earin
g ho
lder
*
17S
haft
was
her/
flatw
ashe
rX
X
18B
alan
ce d
isc
key
XX
19B
alan
ce d
isc
XX
20C
avity
cov
er O
-rin
gX
XX
X
21D
isch
arge
hou
sing
O-r
ing
XX
XX
22C
avity
cov
er re
tain
ing
ring
XX
X
23S
haft
was
her/
flatw
ashe
rX
X
24B
alan
ce d
isc
lock
was
her
XX
25B
alan
ce d
isc
nut
XX
26D
isch
arge
hou
sing
reta
inin
g rin
gX
XX
27P
ump
shaf
tX
28H
P sh
aft b
ushi
ng a
nti-r
oll p
inX
29H
P sh
aft b
ushi
ngX
30H
P sh
aft b
ushi
ng O
-rin
gX
X
31H
PS
C O
-rin
gX
X
32H
PS
C re
tain
ing
ring
X
33A
ssem
bled
flex
cou
plin
gX
X
34S
haft
key
XX
35A
lignm
ent p
ins
X
36S
S s
him
set
X
37Th
rottl
e ni
pple
elb
owX
XX
38Th
rottl
e ni
pple
XX
XX
39Th
rottl
e ni
pple
O-r
ing
XX
XX
XX
X
40D
rain
line
elb
owX
41B
earin
g dr
ain
line
42D
rain
line
con
nect
or
* Not
Incl
uded
in a
ny k
it. C
an b
e pu
rcha
sed
sepa
rate
ly.
© C
opyr
ight
201
7 Fl
uid
Equ
ipm
ent D
evel
opm
ent C
ompa
ny |
ww
w.fe
dco-
usa.
com
- 40
-
MSS
-B/C
Ser
vice
Par
ts K
its C
ompo
nent
s
112
34
56
78
910
1112
1314
1516
1718
1920
2122
2324
2526
27
2829
3031
3233
34
35
36
3738
39
41
40
42
Figu
re 5
7 - M
SS
-B/C
Ser
vice
Par
ts K
its C
ompo
nent
s
112
1131 14
11
1 10
9
MSS
-160
/200
/240
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 41 -
Specifications Continued
Fastener Torque SpecificationsItem Metric StandardPrecision leveling foot top cradle nuts 34 N-m 25 Lb-ftMotor adapter bolts - 3/8" 34 N-m 25 Lb-ftMotor adapter bolts - 1/2" 61 N-m 45 Lb-ftMotor adapter bolts - 5/8" 108 N-m 80 Lb-ftSupport bracket adjustment bolts 81 N-m 60 Lb-ftInlet housing bolts MSS-15 through MSS-75 33 N-m 24 Lb-ftInlet housing bolts MSS-90 through MSS-240 81 N-m 60 Lb-ftInlet housing bolts (HPSC) MSS-15 through MSS-75 33 N-m 24 Lb-ftInlet housing bolts (HPSC) MSS-90 through MSS-240 81 N-m 60 Lb-ftEnd/ Series shell flange bolts MSS-15 through MSS-120 81 N-m 60 Lb-ftEnd/ Series shell flange bolts MSS-160 through MSS-240 109 N-m 81 Lb-ftDischarge housing retaining clip cap screws 10 N-m 7 Lb-ftPump shaft nut (balance disc nut) MSS-15 through MSS-75 68 N-m 50 Lb-ft
Pump shaft nut (balance disc nut) MSS-90 through MSS-120 95 N-m 70 Lb-ft
Pump shaft nut (balance disc nut) MSS-160 through MSS-240 123 N-m 91 Lb-ft
Pump support bracket anchor bolt 108 N-m 80 Lb-ftStage split cone nut MSS-40 through MSS-75 54 N-m 40 Lb-ftStage split cone nut MSS-90 through MSS-120 101 N-m 75 Lb-ftStage split cone nut MSS-160 through MSS-200 162 N-m 120 Lb-ftStage split cone nut MSS-240 203 N-m 150 Lb-ftCoupling set screws (M6/ M10) 9 N-m/ 41 N-m 7 Lb-ft/ 30 Lb-ft
Pump Alignment SpecificationsMotor Adapter Gap Tolerances for Non-Uniform GapsGood ≤ 0.381 mm 0.015"
Balance Disc SpecificationsPump Model Original Thickness When New Wear Limit - 0.508 mm 0.020")MSS-15 through MSS-75 13.5 mm (0.531") 13.0 mm (0.511")MSS-90 & MSS-120 16.0 mm (0.630”) 15.5 mm (0.610”)MSS-160 through MSS-240 15.7 mm (0.618”) 15.2 mm (0.598”)
Lubricants and CompoundsLubricantASTM D1257
Standard Glycerine or fresh water with soap
Anti-seize compound Compliant with specific system
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 42 -
Specifications ContinuedMaintenance Schedule
By following the schedule of preventive maintenance presented below, the MSS pump will deliver years of trouble-free performance.
One (1) day after commissioning1. Recheck pump alignment (refer to Final Pump Alignment).2. Visually inspect flexible coupling and tighten the coupling bolts to the specified torque as nec-
essary.3. Fill out and submit all warranty documentation to FEDCO.
Six (6) months after commissioning1. Inspect pump alignment (refer to Final Pump Alignment).2. Inspect flexible coupling: check for wear, irregularities, torsional backlash, running behavior
and tightening torque (refer to Flexible Coupling Check).3. Inspect for leaks, damaged gaskets and condition of all pipe couplings.4. Wipe pump, motor and baseplate with a clean, damp cloth.
Twelve (12) months after commissioning1. Inspect pump alignment (refer to Final Pump Alignment).2. Inspect flexible coupling: check for wear, irregularities, torsional backlash, running behavior
and tightening torque (refer to Flexible Coupling Check).3. Inspect mechanical seal for early signs of leakage or failure.4. Inspect balance disc (refer to Balance Disc Inspection in the MSS Overhaul Manual).
NOTES: If balance disc requires replacement, mechanical seal should also be replaced.
5. Inspect for leaks, damaged gaskets and condition of all pipe couplings.6. Wipe pump, motor and baseplate with a clean, damp cloth.
Annually1. Inspect pump alignment (refer to Final Pump Alignment).2. Inspect flexible coupling: check for wear, irregularities, torsional backlash, running behavior
and tightening torque (refer to Flexible Coupling Check).3. Inspect for leaks, damaged gaskets and condition of all pipe couplings.4. Inspect balance disc (refer to Balance Disc Inspection in the MSS Overhaul Manual).
NOTES: If balance disc requires replacement, mechanical seal should also be replaced.
5. Wipe pump, motor and baseplate with a clean, damp rag.
Five (5) Years1. Annual maintenance per above.2. Disassemble fluid end for detailed inspection (refer to MSS Overhaul Manual).
NOTES: Follow manufacturer’s recommendations for motor and VFD maintenance.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 43 -
Service Policy
Return Material Authorization (RMA)
Please contact a FEDCO before returning any equipment. You must have a Return Material Au-thorization (RMA) issued by FEDCO before we can accept any parts. All returned parts must be shipped prepaid to FEDCO with the RMA clearly marked on the package. We need this number to ensure proper handling of the returned parts and supply of new parts, if needed. Ask FEDCO for details of the repair warranty. Parts will be replaced in accordance with the FEDCO warranty. Use the following address to return parts:
ATTN: Field Service DepartmentFEDCO 800 Ternes Drive Monroe, MI 48162 USA
Additional Contact Information:Tel: 734-241-3539Fax: 734-241-5173Web site: www.fedco-usa.comChoose the “Service and Support” tab
Procedure
How to Return Parts to FEDCO1. Provide FEDCO with the following information: • Serial number of unit. • Description of why parts are being returned.2. FEDCO will provide a Return Authorization Number.3. Pack the unit in the original shipping crate or other suitable crate and clearly mark the Return Material Authorization on the outside of the crate.4. Send unit, freight prepaid, to FEDCO at the above address.
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 44 -
Service Policy Continued
Start-Up Record □ 1. Flexible coupling set screws tightened. □ 2. Motor adapter guards installed. □ 3. All anchor bolts tightened to specifications. □ 4. All pipe couplings tightened to specifications. □ 5. Motor rotational direction correct. □ 6. Motor lubricated to manufacturers specifications. □ 7. Final Pump Alignment performed. □ 8. Inlet pressure indicator installed. □ 9. Inlet pressure switch (if applicable) installed. □ 10. Outlet pressure indicator installed. □ 11. System pipes are clean and upstream filtration in place. □ 12. System leak checked and all air vented from system. □ 13. ALL safety devices in place.
Installation and Start-up InformationStart-up Date: _________________________ Model #: _______________________________Serial #: ______________________________ Installation Date:_________________________ Installed By: ___________________________
Operating ConditionsFeed Flow: ____________________________ Suction Pressure to Pump:_________________Discharge Pressure: _____________________ Drain flow rate (high inlet pressure option only): _________________________VFD frequency (Hz) if used ________________ Voltage and Hz of power supply_____________VFD Amps: ____________ VFD Amps (after 48 hours of running time): ____________________Baseline vibration reading at pump start-up (optional): ____________
Pump Alignment MeasurementsMotor adapter gap A: __________, B: __________, C: __________, D: __________
Pipe Connection(s) □ Victaulic connection □ Flanged connection: Flange Pipe Size (Inlet) __________, Gap __________ Flange Pipe Size (Discharge) __________, Gap __________
General Notes:______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
This report has been filled out by: __________________________________Date: ___________
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 45 -
Service Policy Continued
Overhaul RecordOverhaul Date: _____________________________
Operating Hours: ___________________________
Reason for Overhaul: _____________________________________________________________________________________________________________________________________________________________________________________________________________________
Operating Data Prior to Overhaul:Feed Flow: ____________________________ Suction Pressure to Pump: _________________
Discharge Pressure: _____________________
Operating Data After Overhaul:Feed Flow: ____________________________ Suction Pressure to Pump: _________________
Discharge Pressure: _________________________
General Notes: ___________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Overhauled by: __________________________
Telephone: _____________________________ Fax: ________________________________
E-mail: ________________________________
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 46 -
Warranty Registration Form
THIS FORM MUST BE COMPLETED AND RETURNED TO FEDCO TO ACTIVATE YOUR WARRANTY COVERAGE.
FEDCO will send confirmation of start of warranty coverage
Please FAX this page to FEDCO to register your warranty.Retain the original for your future information.
FAX to: +734.241-5173 (USA) or E-MAIL to: [email protected]
Initial Installation
Model #: ________________________________ Serial #: ______________________________
Installation Date: _________________________ Startup Date:__________________________
VFD frequency (Hz) if used _________________ Voltage and Hz of power supply ___________
Feed Flow: ______________________________
Suction Pressure to Pump: __________________ Discharge Pressure: ____________________
Drain flow rate (high inlet pressure option only): _________________________
Comments:____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
Installed by: _________________________
Telephone: __________________________ Fax: ________________________________
E-mail:______________________________
- - - - - - - - - - - - - - - - - - - - - - - - -! - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 47 -
MSSTM Series
© Copyright 2017 Fluid Equipment Development Company | www.fedco-usa.com- 47 -
UNIT OPERATION CONDITIONS
PLACE STICKERHERE
These operating conditions are also listed on the back of the unit start-up tag
_____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________ _____________________________________________________________________________
Notes
MSS Unit Operating Conditions
MSSTM Series
Revised September 13, 2017 6:46 AM
Service Center
FEDCO Sales Office
Visit Our Website For the Latest Version of This Document and More Information.
www.fedco-usa.com
FEDCO USAFEDCO
800 Ternes DriveMonroe, MI 48162, USA
Telephone: +1 (734) 241-3935 Fax: 734-241-5173
Email: [email protected]
FEDCO DUBAI Technopark, Plot TP10501
Jebel Ali South, PO Box 37603, Dubai, UAE
Telephone: +971-(0)4 880 7344Mobile: 917-055-774-9805
Email: [email protected]
FEDCO SINGAPORE Singapore Branch
82 Toh Guan Road East#C2-14-4 WaterHub Singapore, 608576
Telephone: +(65) 6779 0123Email: [email protected]