national standards of resistance (measuring: 1 a - 100 ma ...jordan institution for standards and...
TRANSCRIPT
Jordan Institution for Standards and Metrology
Certificate for Approval of a National Measurement Standard
No. I NS I 11 I 2010 I
According to instructions No.(2) for the year 2002 "Instructions ofOrganizing the Measurement and Calibration Activities in Jordan", issuedpursuant to article (5) of the regulation of "National Measurement System",No.(31) for the Year 2001, and JISM law No.(22) for year 2000. JISMhereby approved the
National Standards of Resistance(Measuring: 1 a - 100Ma)
(Source: 1 a - 1 GO)
realized by measurementstandards specified in the attached report No.11/2010, to be kept and maintained by :
Royal Scientific SocietyJordan National Metrology Institute (JNMI)
P.O. Box 1438, AI-Jubaiha 11941, Jordan
The tasks and responsibilities of JNMI with regard to maintenance,traceability and documentation of the National Standards are laid down inthe agreement No. 1/2009.
Official Stamp Director General
Dr. Yaseen Khayyat
~~~~ --;..
Jordan Institution for Standards and MetrologyMetrology Department
Issue date : Feb. lIt, 2010
National Standard of ResistanceReport No. I 11/2010 I
Page No. (1) of (1)
f'"a..c.1 Afb~' t
Information about the Laboratory Environmental ConditionsLab Name: NationalPrimaryLaboratoryforElectricalMeasurementandCalibration/ JNMI Temperature: 23°C:f:l°C
Person in chal"2e: EngFawazAllabadi- Director of Jordan National Metrology Institute Relative Humidity: 50 %:f:10%
Metrologist in charge: Eng Fawaz Allabadi Air Pressure:90 kPa :f:10 kPa
Deputy: En. Ibrahim Sehweil
Equipment Manufacturer Serial No. Range ClasslUncertaint CertificateNo. Issued by Issued Valid Traceableto
& Model y date until BIPMthrough
Digital multimeterAgilent 2823A26805 10-1 GO :f: 100ppm DKD:1I0412009 JNMI 1/1012009 1/10/2011
(measurinl! system) KRISS/KOREAMultifunction calibrator Fluke 7695201
I 0 -100:f: 43 ppm DKD: 110312009 JNMI 1/1012009 1/10/2010 KRISS/KOREA
(variable source) MOMulti-Product Calibrator Fluke 9023007
0.5 m 0-0.1 %
MteP80480S-SP/Sweden 21/1112008 21/1112010 SP/Sweden
1090 MO K03Resistance Standard Fluke 8998006 In :f: 0.1 DDm 0800-04701-011 KRISSlKorea 15/1012008 15/1012013 KRISSlKoreaResistance Standard Fluke 8998007 1.9n :f: 0.8ppm lR1968 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 8998008 Ion :f: 0.8 ppm lR1959 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 8998009 lOOn :f: 0.8 ppm lR1960 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 8998010 1 k.Q :f: 1.2ppm lR1961 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 8999003 10 k.Q :f: 0.3ppm 0800-04701-013 KRISSlKorea 15/1012008 15/1012013 KRISSlKoreaResistance Standard Fluke 8998012 19 k.Q :f: 1.2ppm lR1963 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 9001001 100 k.Q :f: 1.9ppm lR1952 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 8998013 IMn :f: 3.8 ppm lR1955 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 9001002 10Mn :f: 7.7ppm lR1941 JNMI 16/8/2009 16/8/2010 FlukelUSAResistance Standard Fluke 9001003 19Mn :f: 15.4ppm lR1942 JNMI 16/8/2009 16/8/2010 FlukelUSA
Director of Metrology Department OfficialStampO., - -
Eng. Osama Melhem