147 www.lappgroup.com Power and control cables Special applications Photovoltaics New ÖLFLEX SOLAR XLS Cross-linked standard solar cables Temperature range -40°C up to +100°C Robust against mechanical impact Info Part number Conductor cross-section in mm² Outer diameter in mm approx. Copper index kg/km Weight kg/km approx. ÖLFLEX SOLAR XLS Core insulation: black / Outer sheath: black 0025800 1.5 5.4 14.4 29.0 0025805 2.5 5.4 24.0 45.0 0025810 4.0 6.0 38.4 72.0 0025815 6.0 7.1 57.6 102.0 0025820 10.0 8.9 96.0 159.0 0025825 16.0 9.8 153.6 247.0 Core insulation: red / Outer sheath: black 0025801 1.5 5.4 14.4 29.0 0025806 2.5 5.4 24.0 45.0 0025811 4.0 6.0 38.4 72.0 0025816 6.0 7.1 57.6 102.0 0025821 10.0 8.9 96.0 159.0 0025826 16.0 9.8 153.6 247.0 Core insulation: blue / Outer sheath: black 0025802 1.5 5.4 14.4 29.0 0025807 2.5 5.4 24.0 45.0 0025812 4.0 6.0 38.4 72.0 0025817 6.0 7.1 57.6 102.0 0025822 10.0 8.9 96.0 159.0 0025827 16.0 9.8 153.6 247.0 Copper price basis: EUR 150 / 100 kg Our standard lengths, please visit: www.lappkabel.de/en/cable-standardlengths Packaging size: Coil 100 m; Drum (500; 1000) m Comparable products ÖLFLEX SOLAR XL multi see page 146 Accessories EPIC SOLAR - Industrially injection over- moulded and field mountable solar connec- tors for safe connection of PV modules SKINTOP ST / SKINTOP CLICK - Approved cable glands for use for PV junction boxes, electric meters and DC/AC converters Benefits Reduced spreading of fire source and forma- tion of toxic combustion gases in event of fire Exact quantity control during installation by meter marking on the cable sheath Application range For cabling of solar modules among them- selves and as extension cable between the individual module strings or DC/AC inverter Gable and flat roof photovoltaic systems Open land solarfield plants Product features Weathering-, abrasion and UV resistant Good heat pressure resistance Halogen free and flame retardant Resistant against ammonia- and biogases, oxalic acid, sodium hydroxide and other chemical media On request and considering economic mini- mum lenghts also available with with red and blue outer sheath Approvals (Norm references) Flame retardant according IEC 60332-1-2 Halogen free according EN 50267-2-2 Ozone resistant according EN 50396 Weather-/UV resistant according HD 605/A1 Acid-/brine resistant according EN 60811-2-1 Product Make-up Conductor: fine wired tinned copper strands Core insulation: cross-linked copolymer Core insulation colour: black, red or blue Outer sheath: cross-linked copolymer Outer sheath colour: black (RAL 9005) Technical data Conductor stranding fine wire in acc. to VDE 0295 Class 5 / IEC 60228 Cl.5 5 Minimum bending radius fixed installation: 4 x cable diameter Rated voltage AC U0/U : 600/1000 V DC U0/U : 900/1500 V max. permissible operating voltage: DC 1800 V Test voltage 4000 V Range of temperature fixed installed: -40° C up to +100 °C

Upload: others

Post on 20-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: New ÖLFLEX SOLAR XLS SOLAR XLS.pdf · ÖLFLEX SOLAR XLS Cross-linked standard solar cables Temperature range -40°C up to +100°C ... Approved cable glands for use for PV junction

147www.lappgroup.com

Power and control cablesSpecial applications

Photovoltaics

New

ÖLFLEX SOLAR XLSCross-linked standard solar cables

▯ Temperature range -40°C up to +100°C▯ Robust against mechanical impact

Info

Part number Conductor cross-section in mm² Outer diameter in mm approx. Copper index kg/km

Weight kg/km approx.

ÖLFLEX SOLAR XLSCore insulation: black / Outer sheath: black

0025800 1.5 5.4 14.4 29.00025805 2.5 5.4 24.0 45.00025810 4.0 6.0 38.4 72.00025815 6.0 7.1 57.6 102.00025820 10.0 8.9 96.0 159.00025825 16.0 9.8 153.6 247.0

Core insulation: red / Outer sheath: black0025801 1.5 5.4 14.4 29.00025806 2.5 5.4 24.0 45.00025811 4.0 6.0 38.4 72.00025816 6.0 7.1 57.6 102.00025821 10.0 8.9 96.0 159.00025826 16.0 9.8 153.6 247.0

Core insulation: blue / Outer sheath: black0025802 1.5 5.4 14.4 29.00025807 2.5 5.4 24.0 45.00025812 4.0 6.0 38.4 72.00025817 6.0 7.1 57.6 102.00025822 10.0 8.9 96.0 159.00025827 16.0 9.8 153.6 247.0

Copper price basis: EUR 150 / 100 kgOur standard lengths, please visit: www.lappkabel.de/en/cable-standardlengthsPackaging size: Coil 100 m; Drum (500; 1000) m

■ Comparable products▯ ÖLFLEXSOLARXLmultiseepage146

■ Accessories▯ EPICSOLAR-Industriallyinjectionover-mouldedandfieldmountablesolarconnec-tors for safe connection of PV modules

▯ SKINTOPST/SKINTOPCLICK- ApprovedcableglandsforuseforPVjunctionboxes,electricmetersandDC/ACconverters

■ Benefits▯ Reducedspreadingoffiresourceandforma-tionoftoxiccombustiongasesineventoffire

▯ Exactquantitycontrolduringinstallationbymeter marking on the cable sheath

■ Application range▯ For cabling of solar modules among them-selvesandasextensioncablebetweentheindividualmodulestringsorDC/ACinverter

▯ Gableandflatroofphotovoltaicsystems▯ Openlandsolarfieldplants

■ Product features▯ Weathering-, abrasion and UV resistant▯ Good heat pressure resistance▯ Halogenfreeandflameretardant▯ Resistant against ammonia- and biogases, oxalicacid,sodiumhydroxideandotherchemical media

▯ Onrequestandconsideringeconomicmini-mum lenghts also available with with red and blue outer sheath

■ Approvals (Norm references)

  ▯ Flame retardant according IEC 60332-1-2▯ HalogenfreeaccordingEN50267-2-2▯ OzoneresistantaccordingEN50396▯ Weather-/UVresistantaccordingHD605/A1▯ Acid-/brineresistantaccordingEN60811-2-1

■ Product Make-up▯ Conductor:finewiredtinnedcopperstrands▯ Coreinsulation:cross-linkedcopolymer▯ Core insulation colour: black, red or blue▯ Outersheath:cross-linkedcopolymer▯ Outersheathcolour:black(RAL9005)

■ Technical dataConductor strandingfinewireinacc.toVDE0295 Class 5 / IEC 60228 Cl.5 5Minimum bending radiusfixedinstallation: 4xcablediameterRated voltageACU0/U:600/1000V DC U0/U : 900/1500 V max.permissibleoperatingvoltage: DC 1800 VTest voltage4000 VRange of temperaturefixedinstalled: -40° C up to +100 °C

Page 2: New ÖLFLEX SOLAR XLS SOLAR XLS.pdf · ÖLFLEX SOLAR XLS Cross-linked standard solar cables Temperature range -40°C up to +100°C ... Approved cable glands for use for PV junction

�Text am Seitenfuss

Power and control cablesSpecial applications

Photovoltaics

New

ÖLFLEX SOLAR XLR STThe latest solar cable generation according to PV�-F design

▯ According DKE requirements specification (PV1-F)

▯ TÜV Type Approved (2PfG 1169/08.07)

Info

■ Benefits▯ Highthermalcapacityforlonglastingopera-

tionofthePVsystematallseasons▯ Reducedspreadingoffiresourceandforma-tionoftoxiccombustiongasesineventoffire

▯ Variouslycolouredcoreinsulationssimplifyondemandthedifferentiationofthepolarityduringinstallation

▯ Robustagainstmechanicalimpact▯ Exactquantitycontrolduringinstallationby

metermarkingonthecablesheath

■ Application range▯ Forcablingofsolarmodulesamongthem-

selvesandasextensioncablebetweentheindividualmodulestringsorDC/ACinverter

▯ Gableandflatroofphotovoltaicsystems▯ Openlandsolarfieldplants

■ Product features▯ Excellentweather-,temperature-andUV

resistance▯ Goodnotchandabrasionresistance

▯ Goodheatpressureresistance▯ Halogenfreeandflameretardant▯ Resistantagainstammonia-andbiogases,

oxalicacid,sodiumhydroxideandotherchemicalmedia

■ Approvals (Norm references)

     ▯ TÜVTypeApproved-2PfG1169/08.2007▯ HalogenfreeaccordingEN50267-2-2▯ OzoneresistantaccordingEN50396▯ Weather-/UVresistantaccordingHD605/A1▯ Acid-/brineresistantaccordingEN60811-2-1

■ Product Make-up▯ Conductor:finewiredtinnedcopperstrands▯ Coreinsulation:electronbeamcross-linked

copolymer▯ Outersheath:electronbeamcross-linked

CopolymerColour:black(RAL9005)

▯ XLR=X-LinkedRadiated

■ Technical dataApprovalsPV1-F(TÜVTypeapprovedaccording2PfG1169/08.2007)Conductor strandingfinewireinacc.toVDE0295Class5/IEC60228Cl.5Minimum bending radiusfixedinstallation:4xcablediameterRated voltageACU0/U:600/1000VDCU0/U:900/1500Vmax.permissibleoperatingvoltage:DC1800VTest voltageAC6500VRange of temperature40°Cupto+120°Cmax.conductortemperatureAmbienttemperatureaccordingIEC60216-2:+90°C(for25yearslifespan)

Part number Conductor cross-section in mm² Outer diameter in mm approx. Copper index kg/km

Weight kg/km approx.

ÖLFLEX SOLAR XLR STCore insulation: black / Outer sheath: black

0025850 1.5 4.8 14.4 40.00025855 2.5 5.6 24.0 53.00025860 4.0 6.0 38.4 74.00025865 6.0 7.0 57.6 92.00025870 10.0 8.4 96.0 152.0

Core insulation: red / Outer sheath: black0025851 1.5 4.8 14.4 40.00025856 2.5 5.6 24.0 53.00025861 4.0 6.0 38.4 74.00025866 6.0 7.0 57.6 92.00025871 10.0 8.4 96.0 152.0

Core insulation: blue / Outer sheath: black0025852 1.5 4.8 14.4 40.00025857 2.5 5.6 24.0 53.00025862 4.0 6.0 38.4 74.00025867 6.0 7.0 57.6 92.00025872 10.0 8.4 96.0 152.0

Copperpricebasis:EUR150/100kgPleasefindourstandardlengthsat:www.lappkabel.de/en/cable-standardlengthsPackagingsize:Coil100m;Drum(500;1000)m

■ Accessories▯ EPICSOLARModuleBoxseepage[P129367]▯ EPICSOLAR-IndustriallyinjectionovermouldedandfieldmountablesolarconnectorsforsafeconnectionofPVmodules▯ SKINTOPST/SKINTOPCLICK-ApprovedcableglandsforuseforPVjunctionboxes,electricmetersandDC/ACconverters

Page 3: New ÖLFLEX SOLAR XLS SOLAR XLS.pdf · ÖLFLEX SOLAR XLS Cross-linked standard solar cables Temperature range -40°C up to +100°C ... Approved cable glands for use for PV junction

148 www.lappgroup.com

Power and control cablesSpecial applicationsPhotovoltaics

ÖLFLEX SOLAR XLVRobust solar cables with big conductor cross sections

▯ The heavy-duty version▯ For high electrical power loads▯ Suitable for direct burial

Info

■ Benefits▯ Reinforcedoutersheathprotectswellagainst

mechanicalstress▯ Highthermalcapacityforlonglastingopera-

tionofthePVsystematallseasons▯ Reducedspreadingoffiresourceandforma-tionoftoxiccombustiongasesineventoffire

▯ Consideringuniversallyvalidinstallationguidelinesalsosuitablefordirectburial

▯ Exactquantitycontrolduringinstallationbymetermarkingonthecablesheath

■ Application range▯ Forcablingofindividualmodulestringsaswellasforfixedsolargeneratorsandmovedtrackingsystems

▯ Openlandsolarfieldplants▯ Largeconductorcross-sectionsareusedas

collectingmaintotransmithighpowerloadsbetweentheindividualpanel-stringsandasconnectiontotheDC/ACinverterofhugePVplantsresp.solarfields

■ Product features▯ Excellentweather-,abrasion-,temperature-

andUVresistance▯ Halogenfreeandflameretardant

(IEC60332-1-2)▯ Goodresistanceagainstammonia-and

biogases

■ Approvals (Norm references)

  ▯ WeatherproofaccordingISO4892-2

resp.UL1581Section1200

■ Product Make-up▯ Conductor:finewiredtinnedcopperstrands▯ Coreinsulation:specialpolyolefin,cross-linked,black

▯ Outersheath:modifiedcopolymer,cross-linked

▯ Outersheathcolour:black(RAL9005)

■ Technical dataCore identification codeblackConductor strandingfinewireinacc.toVDE0295Class5/IEC60228Cl.5Minimum bending radiusfixedinstallation:4xcablediameterRated voltageU0/UAC600/1000VDC900/1500VTest voltage4000VRange of temperaturefixedinstallation:-40°Cupto+120°Cshort-circuittemperature:+250°C

Part number Conductor cross-section in mm² Outer diameter in mm approx. Copper index kg/km

Weight kg/km approx.

ÖLFLEX SOLAR XLV black0027080 4.0 8.0 38.4 97.00027081 6.0 9.1 57.6 135.00027082 10.0 10.5 96.0 206.00027083 16.0 11.9 153.6 315.00027084 25.0 13.2 240.0 460.00027085 35.0 14.5 336.0 570.00027086 50.0 17.7 480.0 763.00027087 70.0 19.7 672.0 987.00027088 95.0 22.0 912.0 1,276.00027089 120.0 23.8 1,152.0 1,702.0

Copperpricebasis:EUR150/100kgOurstandardlengths,pleasevisit:www.lappkabel.de/en/cable-standardlengthsPackagingsize:Coil100m;Drum(500;1000)mConsideringeconomicminimumlenghtsweproduceonrequestversionswithredresp.bluecoreinsulationcolouroranimprintedcodestripeontheblackoutersheathasdistinctivefeature

■ Accessories▯ SKINTOPST/SKINTOPCLICK-ApprovedcableglandsforuseforPVjunctionboxes,electricmetersandDC/ACconverters

Page 4: New ÖLFLEX SOLAR XLS SOLAR XLS.pdf · ÖLFLEX SOLAR XLS Cross-linked standard solar cables Temperature range -40°C up to +100°C ... Approved cable glands for use for PV junction

149www.lappgroup.com

Power and control cablesSpecial applications

Photovoltaics

ÖLFLEX SOLAR V4AHigh-grade steel armoured solar cables

▯ Protected against rodents and termites▯ New cable design

Info

■ Benefits▯ Stainlesshigh-grade(classV4A)steelwire

braiding protects very effective against mar-tens, rodents and even termites

▯ High thermal capacity for long lasting opera-tion of the PV system at all seasons

■ Application range▯ For the use in PV systems for instance on

stable and barn roofs in densely forested areas and farmsteads

▯ Gable and flat roof photovoltaic systems▯ Open land solarfield plants

■ Product features▯ Excellentweatheringresistance▯ Good resistance against ammonia- and

biogases▯ Flame retardant according IEC 60332-1-2

■ Approvals (Norm references)

  ▯ Weathering test according ISO 4892-2

■ Product Make-up▯ Conductor: fine wired tinned copper strands▯ Core insulation: cross-linked polymer,

Colour: black▯ Outer sheath: special polymer▯ Armouring:

high-gradestainlesssteelwirebraiding(V4A)

■ Technical dataCore identification codeblackConductor strandingfine wire in acc. to VDE 0295Class 5/IEC 60228 Cl. 5Minimum bending radiusfixed installation:4 x cable diameterRated voltageU0/UAC 600/1000 VDC 900/1500 VTest voltage4000 VRange of temperaturefixed installation:-40°C up to +90°C

Copper price basis: EUR 150 / 100 kgOur standard lengths, please visit: www.lappkabel.de/en/cable-standardlengthsPackaging size: Coil 100 m; Drum (500; 1000) m

■ Accessories▯ EPIC SOLAR - Industrially injection overmoulded and field mountable solar connectors for safe connection of PV modules▯ SKINTOP ST / SKINTOP CLICK - Approved cable glands for use for PV junction boxes, electric meters and DC/AC converters

Part number Conductor cross-section in mm² Outer diameter in mm approx. Copper index kg/km

Weight kg/km approx.

ÖLFLEX SOLAR V4A stainless steel0025960 4.0 7.0 38.4 98.00025961 6.0 8.0 57.6 158.0