ESEL EQUIPMENT Oil Equipment
2
WHO WE ARE AND WHAT WE SELL :
Denver Petroleum Services is a servicing company based in Nigeria, supplying industrial products for our value minded customer in over 36 states.
We sell flow meters, dispensing pumps and accessories such as nozzle, hose and lots more. We have offer sales ser-vice and we stock spares.
Since 1997, Denver has promised our customers peace of mind through demonstrated dependability-plus a sense of pride by having selected Denver’s unique combination of quality and value.
3
Contents
Nozzles, Hoses, Reels & Couplings Page 4 — 8
Hand pumps Page 9
Filtration & Fuel Conditioning Page 14 —19
Flow Meters Page 20 — 26
Lubrication & Workshop Equipment Page 10 —13
Powered Pump & Fuel Management Page 27 - 37
Liquid Petroleum Gas (LPG) Page 38-40
Sensors & Gauges Page 41 - 46
Index & Terms & Conditions & Warranty
4
Nozzles, Hoses, Reels & Couplings
Manual Nozzle 3/4”
Only suitable with diesel or biodiesel up to B30. Cast aluminium body. 3/4” BSPF swivel inlet.
Can be used with gravity feed tanks or electric pumps.
Integral hook for tidy storage when not in use.
Max. Pressure 50 psi ( 3,5 bar ) , max. Flow 80 L/min.
Manual Nozzle 1”
Suitable for diesel or petrol
Cast aluminium body. 1’’ BSPF swivel inlet.
Integral hook for tidy storage when not in use.
Max pressure 50 psi (3.5 bar) , max. Flow 100 L/min.
Option with Viton Seal for ATEX
Ultra High Speed Manual Nozzle
Only suitable with diesel or biodiesel up to B30. Cast aluminium body.
Automatically shuts off the flow of fuel when vehicle tank is full.
Ideal for refuelling very large vehicles & heavy plant equipment.
3 position stay open latch.
Complete with 1.5’’ BSPF swivel inlet.
Max. Pressure 72 psi (5bar), max. Flow 250 L/min.
For use with electric pumps only.
DN100
DN101
DN102
5
Nozzles, Hoses, Reels & Couplings
Automatic Nozzles
Automatically shuts off the flow of fuel when vehicle of tank is
full
3 position open latch, which may be disabled if required.
3/4” or 1” BSPF swivel inlet.
3/4” Version 20—60 L/min max. Pressure 50psi (3.5 bar)
1” Version 20—120 L/min max. Pressure 50psi (3.5 bar)
For use with electric pumps only.
Heavy Duty 1.5’’ Manual Nozzle
Ideal for refuelling very large vehicles & heavy plant equip-
ment.
Cast aluminium body.
Can be used with gravity feed tanks or electric pumps.
Suitable for use with diesel or gas oil.
Fixed inlet or swivel inlet version, both 1.5’’ BSPF.
Max. Pressure 101 psi (7 bar), max. Flow rates 350 L/min.
Not for use with petrol.
DN105
DN104
6
Nozzles, Hoses, Reels & Couplings
Cased Reel Oil
DH101 series oil reel 138 bar.
Spring rewind. Heavy duty steel construction, powder coated.
Fully adjustable hose stop.
Supplied with 15m x 1/2’’ BSPM hose & 600mm flexible
inlet hose.
Mounting kit for wall, ceiling, bench or floor mount.
( fixed & swivel mount bracket supplied as standard)
Cased Reel Grease
DH102 series grease reel 345 bar.
Cased reel ideal for use in car workshops.
Spring rewind. Heavy duty steel construction, powder coated.
Fully adjustable hose stop.
Supplied with 15m x 1/4’’ BSPM hose & 600mm flexible inlet hose.
Mounting kit for wall, ceiling, bench or floor mount.
( fixed & swivel mount bracket supplied as standard)
DH102
DH101
Hose Reels For Diesel
Only suitable with diesel or biodiesel B30. Self retracting. Steel construction, powder coated finish.
Supplied with 1m inlet hoses. Max. Pressure 90 psi (6 bar).
Never connect rigid pipe work into inlet.
Name Size Flow Rate Length
DH102 3/4” 70 L/min 8m or 20m
DH103 1” 90 L/min 8m or 14m
DH103
7
Nozzles, Hoses, Reels & Couplings
Hose I.D.: 1/2” - 11/2” Pressure: To 2,500 PSI
Auto Rewind Easily Wraps, Stores & Protects Hose
Reinforced Steel Frame Provides Maximum Strength & Stability
Lubricated Factory-Matched Cartridge-Style Spring Motor
Long Lasting Self-Lubricated Flange Bearings
Cast Iron Lock Ring With Non-Sparking Bronze Pawl
Non-Corrosive Stainless Steel Pawl Spring
Heavy Duty 1” O.D. Stainless Steel Pinch-Proof Rollers
Adjusts To Wall, Floor & Overhead Positions
Swivel Seals: NITRILE (AFLAS, On 1” Models)
SPRING DRIVEN FEATURES:
Low Profile Outlet Riser & Open Drum Slot Design
Full-Flow Swivel Assures Maximum Product Delivery
Multi-Position Lock Ratchet Secures Hose At Desired Length
All Working Parts Are Easily Accessible For Servicing
Hose Reels Hi Capacity - 1.5”
Open Reel Oil
DH105 series oil reel 138 bar.
Spring rewind . Heavy duty steel construction, powder coated.
Fully adjustable hose stop.
Supplied 15m x 1/2’’ BSPM hose & 600mm flexible inlet hose.
Fixed mounting plate.
Optional: Swivel mount bracket supplied.
DH106 series grease reel 276 bar.
Spring rewind. Heavy duty steel construction, powder coated.
Fully adjustable hose stop.
Supplied c/w 15m x 1/4’’ BSPM hose & 600mm flexible inlet hose.
Fixed mounting kit for wall, ceiling, bench or floor mount.
Optional: Swivel mounting bracket supplied.
Open Reel Grease
DH106
DH105
DH107
8
Angle & Inline Check Valves
Fitted in pump suction lines to prevent line drainage/loss of prime.
Brass body, 3 bolt fixing cap, o-ring seal.
Choose : 1 1/2” or 2” BSPF.
Angle or inline.
Diesel or biodiesel up to B30 (nitrile seals).
Petrol or biodiesel up to B30 (viton seals). Range of pressure springs available to prevent fuel loss on
above ground storage tanks.
To choose the correct spring pressure (psi), measure from ground level
to the top of the tank (ft).
6ft = 3 psi 8ft = 4 psi
10ft = 5 psi 12ft = 6 psi
Check Valves With Pressure Relief
Hot weather, long hoses, hose run over and hose reels can
cause pressure build up in pumping systems.
These thermal relief poppets vent the pressure back to the
tank preventing pressure build up.
Stops damage to pumping equipment i.e. meter backs crack-
ing & pump shafts seals leaking.
Stops ZVA type nozzles from letting fuel by causing fuel
spillages.
Nitrile seals.
Nozzles, Hoses, Reels, Couplings & Valves
Cam Groove Couplings
Cam Groove Male/Female coupling BSP-Female, set
size 2"
Cam Groove Male/Female coupling BSP-Female, set
size 1”
DC102
DC103
DC101
9
Hand Pumps
Mobile Fuel Retriever - Bi Direction
Suitable for use with petrol, diesel or oils up to SAE 90.
Must not be used to store fuel.
For safe & easy emptying/filling of fuel from vehicles.
90 litre tank capacity. Equipped with level gauge.
Max. Flow 10-15 litres @ 80rpm. Antistatic earth leads/clamp
Dimensions 1260 mm H x 520mm W x 570mm D.
Delivery/discharge hose 3m. Suction lift 1m, discharge head 3m.
Bi-direction for filling (sucking) & emptying (discharge).
Rotary Hand Pump - DA100
Suitable Petrol, Diesel, Heptane, Kerosene, Stoddard
Solvent, and Light Oils
Capable up to 40 L/min.
Precision aluminium body with cast iron rotor & vanes.
1’’ BSPF inlet, strainer & check valve, 3/4’’ BSPF outlet.
Padlock facility prevents unauthorized use.
Fully serviceable & all spares available.
Complete with meter and 8 ft hose.
Rotary Hand Pump - DA101
This innovative concept combines the simplicity of a rotary hand
pump with the accuracy of precise visual volumetric measurement
that’s compact enough to mount directly to your drum, container or
storage tank.
Adaptable for drums, kegs and storage tanks.
Telescoping suction pipe for containers up to 40” in depth.
Suitable Motor Oil, Coolant Oil, Diesel, Water, Hydraulic Oil
DA103
DA101
DA102
10
Lubrication & Workshop Equipment
Air Operated Oil Pumps
Complete kits with hoses to ease installation, kit contains :
Air pump with stubby suction.
Suction pipe to suit 4ft (1.25m) deep tank or 205 litre drum.
Quick release air connector, 1/4’’.
Filter regulator unit for air supply.
1m x 1/2’’ oil discharge hose.
1m x 1/4’’ air inlet hose.
1/2’’ level ball valve.
For drums and tanks. - 3:1 ratio, max. 12L/min suitable for medium/high viscosity oils.
- 5:1 ratio. max 14L/min suitable for high density oils, or for
where long pipe runs & hose reels are in the line.
Oil Dispensing Kit for 205L drums
A complete oil dispensing kit suitable for use with engine, hydraulic,
Synthetic, gear & transmission oils.
3:1 air operated oil pump with 940 mm rigid suction pump.
4m x 1/2’’ bore oil hose.
Supplied with manual oil nozzle.
Option kit supplied with digital hose end meter.
Wall Mounted Oil Dispensing Kit
A wall mounted oil dispensing kit suitable for use with engine,
hydraulic, Synthetic, gear & transmission oils.
3:1 air operated oil pump & wall mounting bracket.
15m x 1/2’’ open oil hose reel.
Supplied with digital hose end meter.
Optional 5:1 air operated oil pump & wall mounting
bracket.
DL102
DL101
DL103
11
Lubrication & Workshop Equipment
Air Operated Grease Pump
All pumps supplied with double acting suction tubes.
Pump fits to 12.5kg or 50kg or 180kg.
Complete with drum cover and follower plate.
Grease Dispenser
4m x 1/4’’ hose assembly.
Steel braided rubber coated cover.
Zinc plated steel end fittings, BSP M/F cone seat. (F end swivels).
1885 psi (130 bar) burst pressure on delivery hoses.
Code Ratio Air inlet Grease Outlet Maximum
pressure
Regulate air
inlet pressure
DL104
Suitable with
standard
50:1 1/4” F 1/4” F 115 psi
(8 bar)
70-115 psi
(5-8 bar)
DL105
(Suitable with
hose reels)
60:1 1/4” F 3/8” F 115 psi
(8 bar)
87-115 psi
(6-8 bar)
50:1 ratio air operated grease pump.
4m of 1/4’’ bore delivery hose.
Grease gun complete with straight swivel.
Code Mass Drum Cover Follower Plate
DL106 12.5kg 280mm 265mm
DL107 50kg 385mm 370mm
Grease Hose
DL108
DL104-5
DL106-7
12
Lubrication & Workshop Equipment
Mobile Oil Dispensing System
A complete mobile oil dispensing system suitable for use with engine,
hydraulic, synthetic, gear & transmission oils.
3:1 air operated oil pump with 940mm suction pipe.
Supplied with digital hose end meter.
Supplied with 4m x 1/2’’ bore oil hose.
Supplied with heavy duty 4 wheel trolley.
Option 15m x 1/2’’ fixed bracket open oil hose reel.
Note drum not included,
Air Filter Regulator & Lubricator
Enables with the air supply to be regulated at a set pressure prior to
use oil/grease air pumps, air tools & other similar equipment.
It cleans, regulates & lubricates the air supply prior to use.
The air supply is firstly filtered of moisture & impurities then pres-
sure regulated before being dose with a fine airborne
lubricant.
Inlet/outlet 1/4’’ BSPF.
Adjustable pressure 7.25 – 115 psi (0.5 - 8 bar)
Max. Working pressure 217 psi ( 15 bar).
Heavy duty version c/w aluminium bowls.
Air inlet Accessories
Air inlet hose, 1m x 1/4’’ BSPM.
Air inlet oily hose, 7m x 1/4’’ BSPM.
Quick release air inlet 1/4’’ female carrier.
Quick release air inlet 1/4’’ male probe.
Connecting nipple 1/4’’ BSPM parallel - taper.
DL109
DL110
DL111
13
Lubrication & Workshop Equipment
Manual Oil Delivery Nozzle
Only suitable for use with lubrications oils. Supplies with flexible spout or anti drip tip.
1/2’’ BSPF swivel inlet.
Max. Pressure 750 psi (50 bar).
High flow version has rigid spout only, no anti drip tip.
Digital Hose End Oil Meter
Only suitable for use with lubricating oils. Flow rate 1-30L/min. Max. pressure 994 psi (70 bar).
Supplied with flexible spout & anti drip tip.
Accuracy +/- 0.5%.
1/2’’ BSPF swivel inlet.
Non resettable totaliser.
DL112
DL113
Grease Control Gun
For use with air operated grease pumps.
Inlet connection 1/4’’ BSPF straight swivel.
Supplied c/w rigid spout & flexible outlet hose with 4 jaw
connector.
Option Z swivel. Spare straight swivel available.
DL114
14
Filtration & Fuel Conditionning
Bowl Filter - High Speed
Only suitable with diesel or biodiesel up to B30. Heavy duty cast aluminium inline bowl filter.
1 1/2’’ BSPF ports.
Can be used with pumps up to 300L/min.
180 micron stainless steel basket strainer.
Max. Pressure 94 psi (6.5 bar).
Fitted with bottom drain plug.
190 mm between the port faces, 250 mm high.
Tank Dryer - Absorbs Water
Condensations occurs in all fuel storage tanks & causes con-
tamination in the form of water that settles on the bottom of
the tank.
Lower the tank dryer into the tank, attach using the 2.5m cord.
(ensure its sitting on the bottom of the tank).
Has a stainless steel rod/weight inside.
When its fully absorbed any water, the tank dryer swells.
Absorbs 350 ml of water. Check monthly. Ideal for use in vehicles & domestic storage tanks.
Bowl Filter - Small Bore
Aluminium bowl filter for small bore fuel lines.
3/8’’ BSPF ports.
Unscrew filter available.
Spare filter available.
Max working temp, 90 degrees Celsius.
Bowl Filter - Standard
Only suitable with diesel or biodiesel up to B30. inline bowl filter.
1” BSPF ports.
Can be used with pumps up to 100L/min.
180 micron stainless steel basket strainer.
DF103
DF102
DF101
DF100
15
Filtration & Fuel Conditionning
Foot Valve & Strainer
Suitable with diesel or biodiesel up to B30 or water.
Combined foot valve & strainer.
Brass body with a steel strainer mesh.
Spring loaded valve poppet.
1’’ BSPF connection.
Box quantity 10. master carton box quantity 100..
Y Type Strainer
Suitable with diesel, biodiesel up to B30 or water.
Inlet/outlet in direct line, threaded BSPF.
Bowl Filter - Water & Particle
Only suitable with diesel or biodiesel up to B100. Fits on outlet side only. 1’’ BSPF ports.
Cast aluminium head with see through polycarbonate bowl.
Gravity flow max. 45L/min. Pump flow max. 100L/min. Disposable filter elements remove water & particle contamination
at 15 micron.
Fitted with bottom plug for draining water.
Master carton kit box quantity 6, element box quantity 12.
Code Size Color
DF105 1” Brass
DF106 2” Brass
DF107 3” Bronze
Mesh
0.28
0.28
0.5
DF104
DF108
DF105-7
16
Filtration & Fuel Conditionning
Pure Fuel Conditioners
Petroleum diesels typically hold 60ppm of suspended water. At this level,
the water is almost insignificant. Provided the fuel is regularly used and
replenished microbial contamination is rarely a problem, bio-diesels typi-
cally hold up to 25 times more suspended water than petroleum diesel.
The introduction of bio-diesel and bio-diesel blend fuels in recent years,
has greatly increased the potential for problems. Bio-diesel is perfect habi-
tat for vigorous microbial growth.
The time fuel exposed to condensation & leaks, or time in undisturbed
storage before proliferation begins, is dramatically reduced. Today’s bio-
fuels deteriorate much faster than their petroleum forebears. Colony
Forming Units of bacteria grow on the water-fuel interface becoming
heavier until they drop out of the fuel to the bottom of the tank where bio-
films and sludge quickly form.
The bacteria feed on the fuel, but the microbes do not eat ‘all’ of the fuel.
They break down the carbon chains, which reduces the combustible prop-
erties. This leads to poor starting (or failure to start at all), excessive
smoke, reduced power output & blocked filters.
Pure Fuel Conditioners
A safe solution for curbing microbial contamination is to pass the fuel
through a Pure Fuel Conditioner. This is a natural solution to the microbe
problem that, instead of killing the microbes, renders them dormant. In
dormant state the microbe does not reproduce (no sludge) and does not
eat/excrete (no acids, no sugars).
In its dormant state, a microbe passes freely through fuel filters and can be
consumed in the combustion process.
A Pure Fuel Conditioner can be installed at all appropriate points in a fuel
distribution network and, to provide permanent protection from microbial
contamination and restore normal service intervals.
How Pure Fuel Conditioner work
The Pure Fuel Conditioner causes plasmolysis of single cell organisms –
a state in which the cell is dormant.
The powerful magnetic field inside the Pure Fuel Conditioner breaks
down the biomass into individuals cells of less than one micron size.
The dormant cell produces no adhesive shell & will consequently not
form a colony.
Plasmolysed microbial material, being small enough, passes through fil-
ters & is consumed by the engine during combustion.
Plasmolysed microbes in fuel returned to tank remains in a dormant state
for up to 28 days after treatment.
By re-circulating fuel in a tank or storage system, the microbial matter can be maintained in its
fragment dormant condition.
17
Filtration & Fuel Conditioning
Fuel Conditioner - 1’’ Inline 85L/min
This is the perfect PureFuel Conditioner for fitting to fuel dispensers.
Requires no power and little maintenance.
1’’ BSP in line female threads.
Maximum flow : 85L/min or 5100L/hr.
Maximum pressure : 6.9 bar.
Weight : 1.2kgs.
Dimensions : 129mm dia. Body x 53mm thick.
Fixing centres: 155.6mm.
Port to port dimensions: 130mm.
Fuel Conditioner - Alpha Pump
This assembly is designed to fit on the suction inlet of cabinet pumps in place of
the flexible connector.
Requires no power & little maintenance.
Triangular flange both ends.
Supplied with 1 1/2” BSP companion flange, gasket & bolts.
Maximum flow : 85 L/min or 5100 L/hrs.
Maximum pressure : 6.9 bar.
Weight : 2.8 kg.
Dimensions : 130mm wide, 290mm flange to flange.
Flexi section 75mm long.
Fuel Conditioner - Fits on ACV
This version is designed to fit onto the body of a conventional angle check valve,
making it quick & easy to fit onto existing fuel pipe installations with below
ground tanks.
NOTE : it is not impossible to fit both the fuel conditioner & a poppet to the angle check valve simultaneously.
Require no power & little maintenance.
Maximum flow : 85L/min & 5100L/hrs.
Maximum pressure 10 bar.
Weight : 3.9kg.
Dimensions : 255 mm H x 130mm dia.
Check valve body not included. DF110
DF108
DF109
18
Filtration & Fuel Conditioning
Fuel Conditioner - 2’’ inline 200L/min.
This PureFuel Conditioner is designed for inline use on higher flow rate
installations where a short insertions length is required.
Requires no power & little maintenance.
2’’ BSP inline female threads.
Maximum flow : 200L/min.
Maximum pressure : 10 bar.
Weight : 16.4kgs.
Dimensions : 473 mm H x 177mm dia. Port to port : 177mm.
Models for larger bore pipe are also available.
Fuel Conditioner - Inline 600L/min.
This PureFuel Conditioner is ideal for higher flow rate installations
where length isn't important, but radial space is limited,
Requires no power & little maintenance.
1 1/2’’, 1’’, 2 1/2’’, BSP inline female threads.
Maximum flow : 200L/min.
Maximum pressure : 10 bar.
Weight : 6.2 kg.
Dimensions : 429mm L x 90mm dia.
Models are also available for larger bore pipes.
Fuel conditioner - Hose Tails
This PureFuel Conditioner is suitable for fitting directly onto vehicles or
items of plant. It’s integral hose tails allow it to be easily inserted into
existing fuel feed lines.
Requires no power & little maintenance.
8mm, 10mm & 12mm, dia inline hose tails.
Maximum flow : 7L/min or 420 L/hr.
Maximum pressure : 4 bar.
Weight : 0.25kg.
Dimensions : 189mm L & 32mm diameter.
DF112
DF111
DF113
19
Filtration & Fuel Conditioning
Fuel Storage Tank Re-Circulation Kit
Why do I need to re-circulate My Fuel? Contaminated fuel inside storage tanks can cause pump or vehicle filters to
block, in some cases resulting in hefty repair bills.
These issues are caused by microbial contamination (often known as diesel
bugs which are micro-organisms that grow on water present in fuel) biofuel is
hygroscopic (attracts water).
The latest fuels contains a % of bio-fuel (up to 7%) & provide an ideal breed-
ing ground for these bugs.
Even a small % of bio-fuel acts as a detergent cleaning the inside of storage
tanks & pipe work allowing dirt/sludge to be sucked up by pumps, blocking
filters. This sludge also contributes to poor emissions (seen as black exhaust
smoke).
Over these microbes/bugs grow into large colony forming units (CFUs) which
get sucked into fuel lines blocking filters.,
Microbial contamination is mostly seen as sludge that forms in the bottom of
storage tanks & filters.
Storage tanks particularly those with low usage requires a permanent system to
keep the microbes/bugs dormant by re-circulating the fuel to ensure an efficient
microbial treatment.
Kit specification :
Circulates & prevent degradation of fuel inside storage tanks.
Passes through a fuel conditioner to prevent microbial growth.
Fuel is automatically circulated for a preset number of timed periods to ensure
tank contents is re-circulated 1 1/2 times every 28 days.
When the pump flow rate drops below a preset limit (indicating a clogged fil-
ters) the flow switch closes & a warning flight flashes.
External alarm output rates at 230 VAC 10A max.
For use with diesel/biodiesel up to B30. (B100 version optional).
Features a 230V pump unit, inlet strainer, fuel conditioner, flow switch, filter
clogged warning light, timer & mains junction point.
Mounted on wall/tank mounting plate dimensions 520mm H x 420mm W x
230mm D. Compete unit is waterproof.
Choose : for storage tanks up to 40000L (3000 litres per day). for storage tanks up to 65000L (5000 litres per day).
Option : - particle/water filter kit c/w fittings & filter wrench. Other bowl or spin on type filters
- flow meter can be fitted to provide ongoing total of fuel circulating
- remote warning to warn of clogged filter.
20
Flow Meters
Petrol Driven Pump and Meter
Suitable for use with diesel.
Good for delivery of diesel from tankers to day tanks or drums.
Flow rate approx. 150LPM.
Petrol driven pump 1” Inlet/Outlet.
Meter Model DM901 (see previous page for specifications).
2” Brass strainer.
2 pieces hose cam groove coupling 1”.
Hoses & nozzles not included.
Mobile Pump and Meter
Suitable for use with diesel.
Good for receiving Diesel from tankers to overhead/underground tanks.
Flow rate approx. 150LPM.
JPP pump Model 11-4, 1 1/2” Inlet/Outlet.
5.5Hp electric motor, 3 phase, 2860RPM with on and off switch.
Meter Model DM901 (see previous page for specifications).
2” Brass strainer.
2 pieces hose nozzles
Optional: Cam groove coupling 2”.
FPP Meter– DM104
Size 2” Inlet/Outlet with flow rate of 38 to 570LPM.
Max. Pressure 150psi.
Complete with air eliminator and strainer with JPP Pump
either Model 12-5 or 15 –6
Coupled with 7.5hp electric motor complete with on/off switch.
All fixed on metal base.
Optional: Tyres, Hose Nozzles, Flange, Couplings, etc..
DM101
DM103
DM102
21
Flow Meters
1’’ Flow Meter - Model 807
Only suitable for use with diesel or biodiesel up to B30. Robust nutating disc flow meter shows up 999 litres.
19 - 75L/min. 1’’BSPF ports. Max. Pressure 50 psi (3.5 bar).
Accuracy +/- 2% with adjustable calibration. Bruna N seals.
Aluminium housing and cover.
3 digit register. 6 digit non resettable totaliser.
11/2’’ Flow Meter - Model 901
Only suitable for use with diesel or biodiesel up to B30. Robust nutating disc flow meter show up to 9999 litres.
25 - 150L/min. 11/2’’ BSPF ports. Max pressure 50 psi (3.5 bar).
Accuracy +/- 2% with adjustable calibration. Bruna N seals.
Aluminium housing.
4 digit register. 8 digit non resettable totaliser.
Front face can be rotated in 90 degrees increment.
11/2’’ Electronic meter - 900
Only suitable with diesel or biodiesel up to B20. Robust nutating disc flow meter, shows up to 9999 litres.
25 - 150 L/min. 1.5’’ BSPF ports. Weight 2.9kg.
Max. Pressure 50 psi (3.5 bar). Aluminium housing.
Accuracy +/- 1.25% (must be calibrated on site before use).
Electronic display with 4 digit register. 7 digit totaliser.
Low battery indicator. Powered by 2x AA batteries.
Enters sleep mode when not in use to increase battery life.
Memory back up stores totaliser & calibration settings even if
batteries are removed.
Front face can be rotated with 90 degrees increment.
DM106
DM105
DM104
22
Flow Meters
FPP Industrial Meters
FPP Meters’ versatile STEALTH Series is available in a variety of configurations including
mechanical registrations, electronic registration or non-factored pulse output flow sensors.
With only two moving parts and exceptional pressure loss characteristics, Stealth represents
the ideal platform for metering systems.
Registration options :
Mechanical register : 4,5 or 6 digit.
Mechanical register/printer, register/
preset, or register/preset/printer combi-
nation
Battery-powered electronic totalizer or
register
Electronic AC batch controllers, flow
computers, and temperature compensa-
tion
NEMA 4X & NEMA 7/4 enclousers
Accessories :
Inlet strainer for meter protection
Air eliminator on inlet strainer
Air check valve with air eliminator
Mechanical preset (shut-off) valve
Electric or pneumatic preset valve
Pulse output, analog signal & serial port
Pulse isolator/Amplifier/splitter
Pump control signal
Ticket Printer
Note: Recommended protection Inlet strainer, depending upon viscosity, with
20, 40, or 80 mesh basket
FPP meter complete with strainer and air eliminator.
FPP meter complete with strainer, air eliminator,
preset counter, shut off valve and printer.
23
Flow Meters
Features TS10A TS15A TS20A TS30A
Size 1” 1 1/2” 2” 3”
Nominal Capacity 15-150 LPM 23-230 LPM 57-570 LPM 76-760 LPM
Pressure Rating 150 PSI at 100F
40 Bar @ 40°C
150 PSI at 100F
40 Bar @ 40°C
150 PSI at 100F
40 Bar @ 40°C
150 PSI at 100F
40 Bar @ 40°C
Temperature 85°C 85°C 85°C 85°C
Viscosity 300 CST
350 000 CST
(Special Gears)
300 CST
350 000 CST
(Special Gears)
300 CST
350 000 CST
(Special Gears)
300 CST
350 000 CST
(Special Gears)
Connections 1” NSP OR BSP 1 1/2” NSP OR BSP 2” NSP OR BSP 3”NSP OR BSP
M
A
T
E
R I
A
L
S
Anodized
Aluminium
Ryton PPS
Anodized
Aluminium
Anodized
Aluminium
Anodized
Aluminium
Linearity +/- 0.25% +/- 0.25% +/- 0.25% +/- 0.25%
Repeatability +/- 0.1% +/- 0.1% +/- 0.1% +/- 0.1%
Resolution 67PPG 34PPG 51PPG
C
A
L
I
B R
A
T
O
N
Litre
Litre
Litre
Litre
EMR3 INTERCON-
NECT BOX (IB)
METER EMR3 COUNTER PRINTER
Case
Oval gears
Seals
Ryton PPS Ryton PPS Ryton PPS
Viton Viton Viton Viton
Posts 303SS Hard Chrome
Coated
303SS Hard Chrome
Coated
303SS Hard Chrome
Coated
303SS Hard Chrome
Coated
Mechanical
Electronic Any unit of mass Any unit of mass Any unit of mass Any unit of mass
24
Flow Meters
Contoil - Oil Meter
Contoil - the clever solution for consumption
measurement
Shipbuilders and manufacturers of burners use the tried and
tested Contoil range of products to measure consumption.
Contoil offers an optimal cost saving solution for a large
variety of applications, thanks to robust and simple product
technology combined with innovative ancillaries which are
straightforward to use.
The extensive selection of products makes it possible to of-
fer customer specific solutions. It makes no difference
whether the medium is heavy oil, extra light heated oil,
petrol or diesel fuel because Contoil uses the volumetric
measuring principle, ensuring highly reliable measurements
with excellent accuracy and stability. The modular structure
of the range guarantees that you will save time as well as
costs.
Contoil - for guaranteed Customer benefits
Your benefits are guaranteed, no matter whether you use
multifunctional electronic register or mechanical roller
counters. The totalisers feature a direct display to ensure
easy reading. The electronic register offers an 8-digit total-
iser which can be reset. At the touch of button, you can call
up the instantaneous flow rate on the LCD display in litres/
hour. A bar indicator also shows you the current meter utili-
sation as a percentage. You will save time because the dis-
plays are so quick and easy to read and adjustements to the
system or the burner only
require minimum effort.
Digital data storage is an EEPROM ensure that data is
saved under all circumstances, because we leave nothing to
chance when it comes to reliability. The normal commercial
battery has a long lifetime and is quick and easy to replace,
makes child’s play of operating the meter.
25
Flow Meters
Extremely flexible for a wide range of applications: These meters can be supplied with various displays, pulsers, flange drillings
and approvals; multifunctional display or roller counter according to choice.
Long service lifetime: Meters with no dynamic seals, optimised combination of material to ensure
long life
High availability: Easy access to the measuring unit; faults are quickly analysed and rectified
on the spot.
Contoil VZE 15 ... 50 (Standard) Multifunctional display and remote transmission (option)
Electronic display of:
- total counter
- resettable counter
- instantaneous value for flow rate
- other operating data on the service level
Simple to operate
Normal commercial long-life battery
Inductive pulser for control purposes (option)
Housing with threaded connection / flange connection
Contoil VZO4 ... 50 (classic) Volume display and remote transmission
Volume display on roller counter
Reed pulser for remote totalisation (option)
Inductive pulser for control purposes (option)
Housing with threaded connection / flange connection
Contoil VZEA 15 ... 50 / VZOA 15 ... 50 Specially designed for differential measurements
If differential measurements are needed, Contoil oil meters calibrated in pairs offer
the optimal solution in every situation where cost effectiveness is the top priority.
This measuring concept fits smoothly into every system to provide far better
results than any conventional meter - doing away with the costly adaptations and
additions to the system that are familiar feature direct consumption measurement.
Main Technical Data Nominal Diameter mm 4 8 15 20 25 40 50
Inches 1/8 1/4 1/2 3/4 1 1 1/2 2 Nominal Pressure Thread Bar 25 25 16 16 16 16 16
Flange Bar 25,40
Temperature °C 60 60 70, 130, 180
Maximum flow rate l/h 80 200 600 1,500 3,000 9,000 30,000
Continuous flow rate l/h 50 135 400 1,000 2,000 6,000 20,000
Minimum flow rate l/h 1 4 10 30 75 225 750
Start-up approx l/h 0.5 1.6 4 12 30 90 3000
Version with remote sensor
Reed Pulser Inductive pulser _ _
26
DATA:
All communication between the Readers and the server will be based on Data Ser-vices (Please note, service delivery is dependent on the availability of operator ser-vice). Where no service is available, Data will be saved to cache memory built within the reader unit and history will be uploaded to the server when service is re-stored. Pulse meters pass readings to Pulse readers when flow of diesel fuel is passing
through and is based on a complete liter read. Generator ON and OFF detected and recorded (date and time ON and OFF). Generator main battery disconnected and re-connection recorded with date and
time. Main map (Google) to display the position of the sites with red and green
points identifying the run state of the generator as ON or OFF. Reports. The following standard reports are available on client server: Generator Daily Activity Report indicating the duration of generators running over defined periods. Diesel fuel amount used or flowed through the pulse meter. Main Generator Battery detection for disconnection and re-connection. Customization to any reports is Free of Charge and will entail a development
period which can only be determined by the nature of the requested report. De-tailed specification and requirements to be provided by the Client.
User Manuals and training – Will be provided by Denver Petroleum. Web Access - Available to registered users. All data to be backed and maintained at the main Denver Petroleum for up to
two years and is available to the client on request.
Remote Monitoring
27
Diesel suction hose SH25.HN & outlet hose below.
Damper - for portable use if unable to fit relief valve.
Pressure relief valve - 1” or 2” adjusts 1 - 12 bar.
Cam Groove Coupling either 1” or 2”
2’’ Diesel Engine Driven Pump
Only suitable with diesel or biodiesel up to B30. Max. Flow 600L/min. 12.5 litre diesel tank.
Total head 27 metres. Suction lift 8 metres. Dry weight 41kg.
4 stroke engine with recoil start.
Dimensions 600mm H x 530mm W x 450mm D.
Full range of spares available.
Do not run dry.
If used with nozzle/valve as means of control, a pressure
relief valve must be used or warranty void.
Accessories for Engine Pumps
Powered Pumps & Fuel Management
1’’ Engine Driven Pump—125 L/min
Only suitable with diesel, biodiesel up to B30. Max. Flow 125L/min. 1.6 litre unleaded petrol tank. 3.0HP.
Total head 23 metres. Suction lift 9 metres. Dry weight 17 kg.
4 stroke engine with recoil start. 1’’ hose tails & suction strainer.
Dimensions 470mm H x 450mm W x 320mm D.
Do not run dry.
If used with nozzle/valve as means of control, a pressure relief
valve must be used or warranty void.
DP106
DP105
DP107
28
DC Transfer Pump
Powered Pumps & Fuel Management
Features 12 Volt DC
Rotary Vane Pump
24 Volt DC
High Flow Pump
12 Volt
Diaphragm Pump
Construction - pump housing Cast Iron Cast Iron Polypropylene
Explosion - proof motor with
2 sealed ball bearings
1/4 HP
1/4 HP
1/4 HP
Amp draw battery 20 Amp 22 Amp 20 Amp
Maximum flow rate with factory
Provided hose and nozzle
76 LPM
76 LPM
49 LPM
Thermal overload protection Yes Yes Yes
Rotor Compositions Iron Iron —
Spring driven diaphragm — — Yes
Internal Bypass Valve Yes Yes Not Required
Built-in-strainer Yes Yes No
Inlet 1” NPT 1” NPT 1” NPT
Outlet 1” NPT 1” NPT 1” NPT
Threaded tank adapter 2” NPT 2” NPT 2” NPT
Motor Approvals U/L, cU/L, CE U/L, cU/L, CE U/L, cU/L, CE
Built in check valve Yes Yes Yes
Pump may be padlocked Yes Yes No
Nozzle Hanger Yes Yes Yes
Machined carbon vanes Yes Yes N/A
Duty cycle 30 minutes 30 minutes 30 minutes
Series 800C/820 meter
Series 900 meter (gallons or litres) — Yes —
Available Options
Box Contents
Telescoping steel suction pipe - 1” Yes Yes Yes
U/L hose with static wire 1” x 12’ (3.7m) 1” x 12’ (3.7m) 1” x 12’ (3.7m)
Nozzle 1” manual 1” manual 1” manual
15’ (4.6m) 3-wire power cable Yes Yes Yes
Compatible fluids
( Not to be used with fluids that
Diesel fuel, gasoline, kerosene,
mineral spirits, stoddart solvent
Diesel fuel, gasoline, kerosene,
mineral spirits, stoddard solvent
Ethylene Glycol, Diesel Fuel,
Grease, Hydraulic oil, Kerosene,
Applications
29
Powered Pumps & Fuel Management
AC Transfer Pump
Features FR701
Rotary Vane Pump
FR311
High Flow Pump
FR450E
Diaphragm Pump
Construction - pump housing Cast Iron Cast Iron Polypropylene
Explosion - proof motor with
2 sealed ball bearings
1/3 HP
3/4 HP
1/4 HP
Amp draw battery 20 Amp 22 Amp 20 Amp
Maximum flow rate with factory 75 LPM 114 LPM 49 LPM
Thermal overload protection Yes Yes Yes
Rotor Compositions Iron Iron —
Spring driven diaphragm — — Yes
Internal Bypass Valve Yes Yes Not Required
Built-in-strainer Yes Yes No
Inlet 1” BSPT 2” NPT 2” NPT
Outlet 1” BSPT 1” BSPT 1” NPT
Threaded tank adapter 2” BSPT 2” BSPT 2” NPT
Motor Approvals U/L, cU/L, CE U/L, cU/L, CE U/L, cU/L, CE
Built in check valve Yes Yes Yes
Pump may be padlocked Yes Yes No
Nozzle Hanger Yes Yes Yes
Machined carbon vanes Yes Yes N/A
Duty cycle 30 minutes 30 minutes 30 minutes
Available Options
Series 800C/820 meter Yes - Series 800C — Yes - Series 800C/820
Series 900 meter — Yes —
Telescoping steel suction pipe - Yes Yes Yes
U/L hose with static wire 1” x 12’ (3.7m) 1” x 12’ (3.7m) 1” x 12’ (3.7m)
Nozzle 3/4” manual 1” manual 1” manual
15’ (4.6m) 3-wire power cable Yes Yes Yes
Compatible fluids
( Not to be used with fluids that
have a flash point of 100F or
Diesel fuel, gasoline, kerosene,
mineral spirits, stoddart solvent and
heptane
Diesel fuel, gasoline, kerosene,
mineral spirits, stoddard solvent
and heptane
Ethylene Glycol, Diesel Fuel,
Grease, Hydraulic oil, Kerosene,
motor oil and Water
Applications
Box Contents
30
Powered Pumps & Fuel Management
Only suitable with diesel or biodiesel up to B30.
Meter. Nutating disc, accurate to +/- 2%.
Pumping unit. Standard duty direct drive vane pump.
Motor. Continuously rated c/w thermal cut out.
Cabinet. Top part has polyethylene cover with painted side.
Display. Mechanical display.
Standard equipment. 4m delivery hose & automatic nozzle.
Dimensions. Vision only 420mm H x 450mmW x 440mm D. (Inc. Nozzle)
Floor mount cabinet 900mm H x 390 W x 290mm D.
10:1 pulser connection to fuel management optional.
Floor mount cabinet (with removable front) optional.
Vision Diesel Pump
Code Flow rate Resettable Digit
Totaliser
DV60 50L/min 3 6
DV80 80L/min 4 7
DV100 100L/min 4 7
230V Diesel Pump
Only suitable for diesel or biodiesel up to B30.
Pumping speed 60, 80 & 100L/min. 230V .
Direct drive, self priming, vane pumping unit. 1” BSPF
ports.
Switch & 2m mains lead. Integral filter & bypass.
Weatherproof to IP55 for outdoor use.
Continuously rated motor with thermal cut out.
DP104
DP101-3
31
Powered Pumps & Fuel Management
Fleet Dispenser Commercial Series
DM-5200 Commercial Series is the ideal solution in Stand Alone or fleet
applications, as it offers the high advantages of latest technology and dura-
bility combined with absolute competitive price.
Exterior housing:
All external metal panels are electro-statically painted for excellent appear-
ance and long life. Durable in harsh environmental conditions.
Hydraulics
Meter: high accuracy, positive displacement meter.
Pumping unit: Vane type with built in air eliminator, Filter, Check Valve and
adjustable By-Pass Valve.
Electric motor
Heavy duty Ex-Proof Motor, Single or three phase , 220 or 380v / 50Hz
Suitable for continuous work.
Electronics
The electronic computing head operates according to the latest technology,
providing highest protection with built-in diagnostics using error codes. Com-
patibility with most Fleet Management Automation Systems.
Flow meter
Positive displacement meter, corrosion proof, composed of materials with long-life and long wear characteristics . Measuring accuracy with : +/- 0.2%.
Cylinder cover adjustment device provides easy field calibration.
Having a micro exterior adjustment.
Min. Flow rate: 5 lpm.
Max. Flow rate: 90 lpm.
Minimum adjustable quantity: 0.025%.
Delivery capacity per revolution: 0.5L
Repeatable tolerance: +/- 0.1%.
Applicable with unleaded gasoline 15-20% MTBE / Gas Oil / kerosene.
Suction Pump
Sliding vane type. Suction head 4 meters.
Equipped with air eliminator, standard filtration, adjustable by-pass valve and control valve.
The driving of the pumping unit is done by belt drive.
Min. Flow rate: 5 lpm.
Max. Flow rate: 90 lpm
Electronic display
LCD type, double sided with easy and clear readability under direct sunlight conditions and extremely good night visibility.
Liquid Crystal for the total litter (volume) : 6 digits.
The fuel pump has safety feature (passwords to prevent tempering or accidental resetting by anyone unauthorized.
Display of error codes for easy diagnosis. All data are protected by back up battery.
Nozzle: Automatic nozzles, size 3/4” / 1” / 11/4”
Hose: Dispensing antistatic oil resistant hose, high quality. Size : 3/4” / 1” / 11/4”. Length: 4m (Optionally any other required length)
Options :
- Volume preset - High hose mast - Emergency stop button
- Breakaway Couplings - Hose reel contractor - High capacity skid refuellers
- Full range of swivels - Full range of nozzle options
32
Powered Pumps & Fuel Management
- Model : DM-5225-T One Product - Two Hoses
Nominal Flow Rate : 45 LPM
-Model : DM-5213 One Product - One Hose
Nominal Flow rate 45 LPM
Electronic Fuel Dispenser
Technical Specifications
Pumping Unit
Suitable for continuous performance under harsh conditions (heavy duty). Posi-
tive displacement, sliding vane design. Efficient, low power consumption.
Equipped with air separator , filter, adjustable bypass valve. The driving of the
pumping unit is done by belt drive.
Flow meter
Positive displacement four piston meter, corrosion proof, composed proof, composed of materials with long life and long wear characteris-
tic. Measuring accuracy with +/- 0.2%. Cylinder cover adjustment device provides easy field calibration. Fitted with a micro exterior ad-
justment. Minimum adjustable quantity : 0.025%.
Delivery capacity per revolution: 0.5L Repeatable Tolerance: +/- 0.1%. All main rotating parts are hydraulically balanced to minimise the
wear for smooth performance. Meter assembly is guaranteed for heavy-duty operation and all fluids handled (unleaded gasoline 15%-20%
MTBE, or gas oil, or kerosene).
Electric motor
Single phase 220V / 50 Hz
1.0HP
Ex-proof ATEX Certified Motor fan cooled.
Electronic Display
LCD back-light display, double sided with easy and clear readability under direct sunlight conditions and extremely good night visibility.
Liquid Crystals for the total money (sale) display : 6 digits.
Liquid Crystals for the total litre (volume) display: 6 digits.
Liquid Crystals for the cost per litre (unit price) : 4 digits.
Electronic Registration Litres. The computer has two types of delivery control, which are manual and programmed. The fuel pump has
Cash/ Volume Preset.
Our fuel Pump is equipped with a keypad to set up the selling price and have security and authorisation feature (passwords) to prevent tam-
pering or accidental resetting by anyone unauthorized. Allows display of error codes for easy diagnosis.
Electromechanical Totalizers Nozzle
Non-resettable electromechanical totalizer for volume: 7 digits Automatic Nozzle, size 3/4”
The totalizer is temper proof and clearly visible from outside All fuel pumps will be equipped with a nozzle locking device.
and easy to read.
Hose
Back-up Power Dispensing antistatic oil resistant hose, high quality.
Back up battery of 72 hours for memory and 15 minutes for display. Size: 3/4”
The battery are automatically recharged on restoration of Length: 4m,
supplied power.
33
Powered Pumps & Fuel Management
AC Transfer Pump
These mechanical pumps are constructed from stainless steel, they feature a single volume only, hand reset register with an optional pulse output,
and are supplied complete with hose and automatic nozzle assembly.
Models are available in three different speed versions, with full air-separating hydraulics for use with petrol or diesel fuels store above or below
ground.
.
All models With full air separating hydraulics, for use in conjunction with below
ground storage, suitable for both diesel fuels and petrol.
- single grade, single hose
- single volume only mechanical register
- accuracy +/- 0.5%
- safety break
High and Mid Speed Models
- nominal dispensing 45LPM - 3/4”hose and slime line ZVA nozzle
Mid Speed Mono
- nominal dispensing 70LPM - 3/4”hose and slime line ZVA nozzle
High Speed Mono
- nominal dispensing speed 90LPM - 1” hose and ZVA25 nozzle
All models With full air separating hydraulics, for use in conjunction with below
ground storage, suitable for both diesel fuels and petrol.
- single grade, single hose
- single volume only mechanical register
- accuracy +/- 0.5%
- safety break
Split Speed Twin Model
- nominal dispensing speed 45/90LPM - 3/4” 1” hose and slime line/ZVA25 nozzles
Mid Speed Twin
- nominal dispensing speed 70LPM - 3/4” hose and slime line ZVA nozzle
High Speed Twin
- nominal dispensing speed 90LPM - 1” hose and ZVA25 nozzle
Standard features All units are manufactured & certified to EN13617-1 to allow in-
stallation on a petrol island. SIRA Certificate number
Options
Solid stainless steel construction Pulser to output data to fuel management until 10PPL + 100PPL
0.5% meter accuracy High hose option
Single mechanical register Matching stainless steel under pump plinths
Top quality hoses, hose break coupling and auto ZVA Nozzles Under pump cradles/stools for new installations
Integral hoses locking (no padlock)
Ambient operating temperature -20°C to +40°C
Commissioning and 12 months on-site warranty.
34
Powered Pumps & Fuel Management
Pump With Fuel Management System
Pump Integral Fuel Management System
Uses virtually indestructible datatags instead of keys or cards.
Up to 65000 different datatags
Odometer entry, odometer check & MPG calculation.
GPRS modem for remote access to fuel data.
User friendly Windows based software package.
Flexible report writer enables a wide range of fuel usage analysis by vehicle, department, vehicle
type, fuel type, time, date etc.
Multiple site capability & data consolidation.
All features included as standard. No optional extras to purchase.
Installation & commissioning support available.
Pump - 230V
Larger, clear, backlit, easy to read LCD display.
Lifetime & period totalisers are displayed constantly.
Leave messages for specific drivers.
Large display digits for fuel being drawn.
Can be used with above or below ground tanks.
Stores full information of the last 2000 refuelling operations.
Integral GPRS modem for downloading the information into your PC.
GPRS Modem No trenches to dig, ducting of cables to install, fitted as standard.
Allows remote diagnostic & support.
Provides wireless communication between pump & PC.
Supplied c/w 12 month line rental.
Datatags Guaranteed for life, if it fails we will give you a new one for free. The datatag is short range proximity
device. It’s 100% sealed plastic unit that is durable & hard wearing. There are no moving parts, no teeth
to break or slots & grooves to wear or block.
It features :
No electrical contacts to cause connection problem.
No batteries to replace or re-charge.
Robust and sealed, guaranteed for life.
The datatags can be programmed with customer information prior to delivery. The datatags can be pro-
grammed with the following fixed information :
Up to 65000 tag numbers.
Up to 65000 different site codes .
Up to 65000 customer codes.
They also carry variable information :
Fuel type allowed & date that the datatag was last used.
Last enter odometer reading.
Access method required to draw fuel, i.e. does this tag require an odometer reading or not
35
Powered Pumps & Fuel Management
The software package
Easy to install & simple to operate, yet comprehensive, will run on a PC using a Windows 95, 98,
2000, NT, XP, Vista & Windows 7 operating system.
The system comes with a number of pre-prepared reports supplying the regular information required
by most fleet managers. The pre-prepared reports can be edited to suit your needs or create new
reports from scratch. Information can be sorted and totalled by vehicle, date, department, etc. Filters
can be set to show the information for a particular vehicle, vehicle type, department, fuel type, etc.
Data can be improved from a whole range of third party fuel card services & integrated with trans-
actions gathered from the pump. Data can be accepted from any of the following card systems : -
Shell, BP, Allstar, Keyfuels, UK Fuels, Fuelserv, Petroplus.
Denver are able to programme the software & datatags with your customer details prior to delivery, enabling a quicker installation. We also offer on site installation & commissioning service on the
software.
Refuelling transaction information
The pump has no printer to jam or paper to absorb moisture, the transactions are viewed via the PC
software. Each pump can store up to 2000 separate refuelling operations, for each refuelling the
following information is recorded :
- Time & date. - Site code (site number).
- Datatag number. - Fleet number. - Registration number. - Group or department number.
- Vehicle type code. - Odometer reading, if required.
- Amount of fuel drawn. - Type of fuel drawn.
The pump stores information for each individual refuelling. Adding, totalling, reporting, and print-
ing are all done via the software PC.
Backlit LCD display Clear even in direct sunlight or at night. The display features :
User instructions.
Fuel quantity currently being dispensed. Up to 9999.9 litres.
Lifetime totaliser fixed. Period totaliser, which may be reset.
Details of the last refuelling, date, time, fuel dispensed & user ID.
Numeric Keypad :
Provides a second level of security. The keypad is vandal resistant & fully weatherproof. It’s used
for entry PIN codes, driver codes or odometer readings. It features :
Positive travel given good user fuel.
Widely spaced keys for easy use , even with gloves on.
Proven operation in door entry systems.
36
Powered Pumps & Fuel Management
FC10 Pump c/w Fuel Management System
FC10 TAGR
Datatag for FC10 System
37
Powered Pumps & Fuel Management
FC10 Pump Multiple Dispenser
FC10.2P System Set Up
FC10.4P System Set Up
Master & Slave
System Set up
When linking to One or up to Three existing/New Stand alone pumps We offer an expansion box, this works by linking the FC10 via a hard wirer to the stand alone pump/pumps.
FC10 Up to 5 FC10 Slave Units
When Multiple Dispensing are required on site (more than 4)
Use a master FC10 linked to a slave version, the advantage of this system over the above expansion box is up
to 5 slaves can be linked to one master FC10 making it a 6 system pump.
Also each slave has its own keypad so if you had an accident damage you can still use the others. With the
expansion system above if damage occurs to the main FC10 & puts it out of action you cant monitor the fuel
usage on the other that are linked in.
38
Liquid Petroleum Gas (LPG) .
Registration :
TS Series flow meters can be used with all major elec-
tronic register system. Not all registers can be supplied
with Tuthill Transfer Systems. Available with the
EMR register factory installed.
Calibration : any unit with K factor > 1.00
Optional : Currency function.
Temperature/Volume compensation
Pulse, Analogue or Serial Port
communications.
Accessories :
Inlet strainer with check valves.
Vapour eliminator with relief valve mounted on
strainer.
Backpressure valve for enhanced vapour elimination.
FPP Meters’ versatile STEALTH Series is available in a variety of configurations including mechanical registrations, electronic registration or non-factored pulse output flow sensors. With only two moving
parts and exceptional pressure loss characteristics, Stealth represents the ideal platform for metering
systems.
Liquefied petroleum gas (also called LPG, GPL, LP Gas, autogas, or liquid propane gas) is a flammable
mixture of hydrocarbon gases used as a fuel in heating appliances and vehicles. It is increasingly used as
an aerosol propellant and a refrigerant, replacing chlorofluorocarbons in an effort to reduce damage to
the ozone layer.
LPG Flow Meter
LPG Industrial meter
39
Liquid Petroleum Gas (LPG) Features TS06A TS15A TS20A TS30A
Size 1” 1 ½” 2” 3”
Nominal Ca-pacity
7 – 70LPM 45 -227LPM 75 – 380LPM 150 – 760LPM
Pressure Rating
350 PSI at 100F 24 Bar @ 40ºC
150 PSI at 100F 40 Bar @
40ºC
150 PSI at 100F 40 Bar @ 40ºC
150 PSI at 100F 40 Bar @ 40ºC
Temperature -40ºC to 150ºC -40ºC to 150ºC -40ºC to 150ºC -40ºC to 150ºC
Viscosity 300 CST
350 000 CST
(Special Gears)
300 CST
350 000 CST
(Special Gears)
300 CST
350 000 CST
(Special Gears)
300 CST
350 000 CST
(Special Gears)
Connections 1” NSP OR BSP 1 ½” NSP OR BSP
2” NSP OR BSP 3” NSP OR BSP
M
A
T
E
R
I
A
L
S
Case Anodized Alumin-ium
Anodized Alu-minium
Anodized Alumin-ium
Anodized Alu-minium
Gears Stainless Steel With Carbon Bear-
ings
PPS With Car-bon Bearings
PPS With Carbon Bearings
PPS With Car-bon Bearings
Posts HC303SS HC303SS HC303SS HC303SS
Valve Cast Iron
Piston Brass Brass Brass Brass
Seals UL Buna N UL Buna N UL Buna N UL Buna N
Linearity +/- 0.5% +/- 0.5% +/- 0.5% +/- 0.5%
Repeatabil-ity
+/- 0.2% +/- 0.2% +/- 0.2% +/- 0.2%
Resolution 380 PPG 380 PPG 75 PPG 50 PPG
Pulsers Hall Effect Std
(Requires External DC Power)
Hall Effect Std
(Requires Ex-ternal DC
Power)
Hall Effect Std
(Requires Eternal DC Power)
Hall Effect Std
(Requires Exter-nal DC Power)
40
Liquid Petroleum Gas (LPG)
Autogas dispensers - Hi-Light dispenser Mechanical specifications
Dimensions: L: 90.5 cm, W: 50 cm, H: 159 cm
Connection sizes: Liquid inlet ¾” NPT
Vapor return line ¾” NPT
Recommended flow range: 6 – 60 lpm
Maximum working pressure: 25 Bar
Safety relief valve opening pressure: 14 Bar
Recommended operational temperature: -40°C to +60°C
Overall accuracy: ± 0.5%
Packaged weight: 1-nozzle (approximately) 295 kg
2-nozzle (approximately) 390 kg
Autogas dispensers - H-style dispenser Mechanical specifications
Dimensions: L: 100 cm, W: 50 cm, H: 180 cm
Connection sizes: Liquid inlet ¾” NPT
Vapor return line ¾” NPT
Recommended flow range: 6 – 60 lpm
Maximum working pressure: 25 Bar
Safety relief valve opening pressure: 14 Bar
Recommended operational temperature: -40°C to +60°C
Overall accuracy: ± 0.5%
Packaged weight: 1-nozzle (approximately) 256 kg.
2-nozzle (approximately) 340 kg.
Autogas dispensers - XT-style dispenser Mechanical specifications
Dimensions: L: 130 cm, W: 50 cm, H: 235 cm
Connection sizes: Liquid inlet ¾” NPT
Vapor return line ¾” NPT
Recommended flow range: 6 – 60 lpm
Maximum working pressure: 25 Bar
Safety relief valve opening pressure: 14 Bar
Recommended operational temperature: -40°C to +60°C
Overall accuracy: ± 0.5%
Packaged weight: 2-nozzle (approximately) 510 kg.
.
41
Gauges and Sensors
Liquid Level Sensor
The Model T/LL200 series is designed for use in tanks requiring continuous level measurement of their contents and provides a voltage or 4-20mA output suitable for connecting into a PLC or process related
applications.
The device has no moving parts and utilises hydrostatic technology incorporating a pressure transducer to
measure the height of liquid. The flexible tube allows the sensor to be fitted easily and to tanks where a
swing arm device is not practical.
Dimensions:
Tank depth: Min 400mm, Max 4000mm (15.8” to 158”) *
Mounting: 1/2” BSPT, 1/2” NPT, 1” BSP or optional 5 holes SAE flange Note: Max tank depth for fuels is 4000mm (158”) and for water is 3500mm
(138”).
Electrical:
Supply voltage: 12 or 24Vdc nominal
Supply current: 6mA@12Vdc
Connections: 4 way Delphi Packard connector (Metri-Pak 150 series)
Output signal: 0-5V (±0.5%) or 4-20mA
Accuracy: ±2.5% of total fluid depth
Construction:
Housing: 30% glass filled Nylon 6
Sensor tube: Polyurethane flexible tube
Seals: Viton
Maximum ratings:
Supply voltage: 8 - 34Vdc
Pressure (Hydrostatic): 5 psi
Fluid Types: Fluids compatible with Stainless Steel, PA6, polyurethane & Viton
Environmental Ratings:
Temperature - operating: -20ºC to +85ºC (-4ºF to +185ºF)
Sealing: IP67
Storage: -55ºC to +105ºC (-67ºF to + 221ºF)
Shock 50g 6.3mS
EMC: Designed to meet EN ISO 13766
Vibration: 1.5mm 10-40Hz (600 - 2400RPM)
Liquid Level Sensor
The Model T/LL130 series is designed for use in water, coolant or fuel/oil tanks and provides a variable resistive, voltage or PWM (Pulse Width Modulated) output suitable for driving industry standard fuel gauges or
connecting into plcs.
The device has no moving parts and can be mounted at any angle as long as it covers the whole depth of the tank.
An optional manual calibration feature is available.
Dimensions: Probe length: Min 200mm, Max 2000mm (Min 7.9”, Max 78.75”)
Electrical: Supply voltage:7-35Vdc Supply current: 15mA@12Vdc approx
Operating frequency: 8.3kHz Output signal: Factory set resistance range or
Warning output: On...1/8 tank as default factory set between 0-5V or 5-0V
Connections: 4 way Delphi Packard connector Linearity: 1%
(Metri-Pak 150 series) Accuracy: ±2.5% of total probe length
The voltage output consists of a voltage follower with a 100Ω resistor to
limit the current draw. The load placed on the output must be greater than 10KΩ.
Construction: Housing: 30% glass filled Nylon 6 Internal sensor: PTFE covered stainless steel
Sensor tube: Stainless steel 316 Seals: Fluorosilicone rubber
Fluid Types: Fluids compatible with 316 St/St, Nylon 6, PTFE & Nitrile rubber. N. B. Not suitable for fuels which contain Toluene
Environmental Ratings: Temperature : - operating: -40ºC to +85ºC (-40ºF to +185ºF) ` Sealing: IP67
- storage: -55ºC to +100ºC (-67º to +212ºF) Shock: 50g 6.3mS
Vibration: BS EN 60068-2-64:1993 (15.3grms) Max tank pressure: 2.0 bar [29 psi]
- +
100R
C1
Vout
42
Gauges and Sensors
Fuel Level Sensor
Dimensions: Probe length: Min 200mm, Max 1100mm (Min 7.9”, Max 43.3”)
Electrical: Supply voltage: 12 or 24Vdc nominal Supply current: 8mA@12Vdc + output load System frequency: 8kHz Connections: 500mm long flying leads which can
be optionally fitted with any specified
receptacle,
Accuracy: ±2.0% of liquid height (-5ºC to +60ºC)
±3.0% of liquid height (-20ºC to +85ºC)
Outputs: Resistive: One from: 10-180Ω, 240-33Ω or 3-180Ω (Emulated resistive output)
Voltage: Selectable: 0-5V, 5-0V or any voltage range in between these limits (ascending or descending)
Alarm: Switch to ground at 1/8 tank depth - max load 100mA. Optionally adjustable between empty and full.
Warning Output Load: 100mA max.
Construction: Housing: 30% glass filled Nylon 6 Internal sensor: Epoxy resin coated FR4 fibre glass
Sensor tube: Stainless steel 316 Wetted seals: PTFE
Internal insulators: PTFE
Fluid Types: Diesel, biodiesel, kerosene, petrol. Not suitable for fuels which contain >5% ethanol.
Environmental Ratings: Temperature - operating: -40ºC to +85ºC (-4ºF to +185ºF) Sealing: IP67
- storage: -40ºC to +105ºC (-40ºF to +221ºF) Shock: 50g 6.3mS
Max tank pressure: For use in unpressurized tanks Weight: 300g (1M long unit)
Vibration: BS EN 60068-2-64:1993 (15.3grms) EMC: Type of approval in accordance
Wire colour codes: with EN ISO 13766:2006
Red: V+ (9 ~ 34V), Yellow: LLA max 100mA
Green: V- (Ground), Blue: Signal out (Ω or V)
The Model T/LL140 series is a range of highly advanced sensors for continuously measuring
the contents of a fuel tank. Their main feature is that they auto-recalibrate when the fuel is at the
full level and the sensor’s electronics negate the effects of changes in the fuel’s dielectric con-
stant caused by the use of different fuels or percentage of additives being used. Additionally,
the probe has the facility to fit fuel feed and return pipes (max 10mm) within the standard SAE 5 holes flange interface. Another useful facility is that the user can cut the sensor probe
to length to suit the tank depth.
A low level alarm switches when the fuel drops below a predetermined level (default is 1/8th of
the tank), but the alarm point can be optionally specified anywhere between 0-100%.
43
Coolant Alarm Switch
The model S85 is an active device which is designed to give an alarm signal if fluids falls be-
low or rises above a preset level. It will only signal after a few seconds delay in sensing the
level to eliminate false alarms due to turbulence.
Containing a programmable microprocessor, the switch can offer one or two output pins which
can sink to ground or supply a source of voltage, or both.
Its tiny footprint with limited intrusion into the tank means a reduced risk of damage and a wide
range of options and customisations makes it suitable for most applications.
Electrical rating; Supply voltage:5 VDC or 7 - 35 VDC
Supply current: 1.5mA + source output
Max. Load Current:1.0A (sink) or 20mA (source)
Alarm delay time:0 - 25 secs rising or falling
Connection: 4 way Delphi Packard Connector
Start up delay: 1-5 secs
Fluid types: Water based fluid compatible with Brass, PTFE, and NBR rub-
ber.
Construction: Body: Brass
Probe: PTFE
Terminals: SAE CA210Brass, Tin Plated
Seals: NBR Rubber
Connector: 30% Glass Filled Nylon
Thread: Vibra-Seal 516
Environmental Ratings: Sealing: IP67
Max. Pressure: 5.0 Bar (72psi)
Temp. Ranges:
Fluid: -40°C to +130°C
Storage: -40°C to +140°C
Weight: 53g
Vertical Float Switches
The T/LL70 series is a comprehensive range of vertical float level switches designed around the proven and reliable magnet and reed switch principle.
Comprising many build variants, the T/LL70 is customised to each application by means of materials, connection, header style, reed rating etc.
Electrical : Reeds : - quantity: up to 12 switched level
- switching; N/O, N/C, changeover or latched
- current: up to 3.0A
- power : up to 100VA - voltage : up to 300VAC
Construction : Header :Brass, PVC or 316 stainless steel
Stem : Brass, PVC or 316 stainless steel
Float : Bruna N, Polypropylene or 316
stainless steel.
Fitting : Standard: 1/2” BSP, 1” BSP, 1.1/2”BSP.
Optional: Many other thread sizes, push fit, flange
mount
Terminations : IP67 terminal box, DIN connector, flying leads
Fluid Types : Fluids compatible with the construction material.
Gauges and Sensors
44
Gauges and Sensors
Miniature Float Switches
The Model T/E-C series miniature float switches complements
our existing range of multi-level float switches.
Designed around the proven and reliable magnet and reed
switch principle, they can be mounted in the top, bottom or side, via the right angled option, of a tank, and are available in
many materials as the table below:
Wetted
Materials
stem/float
Float O.D. Mounting
Threads
Brass/Nitrophyl 26.25mm 1/8” NPT
Brass/PP 28.5mm 1/8” NPT
SS316/SS316 30mm 1/8” NPT
SS316/Nitrophyl 26.25mm 1/8” NPT
SS316/PP 28.5mm 1/8” NPT
Brass/Nitrophyl 26.25mm 1/8” BSPT
Brass/PP 28.5mm 1/8” BSPT
SS316/SS316 30mm 1/8” BSPT
SS316/Nitrophyl 26.25mm 1/8” BSPT
SS316/PP 28.5mm 1/8” BSPT
SS316/SS316 30mm 1/8” BSP
SS36/SS316 30mm 1/8” NPT
Specification
Fluid Types: Construction:
Fluids compatible with the construction materials Stem: Brass, 316 Stainless Steel
Header: Brass, 316 Stainless Steel Float: Brass or 316 stainless steel or Polypropylene
Environmental ratting Electrical:
Temperature operating: -40ºC to +110ºC 0.5 A, 10 W @ 300VDC, 240VAC
Pressure Non stainless steel: 100psi
Stainless steel: 300psi Min. S. G. of liquid
Nitrophyl 0.23
45
Gauges and Sensors
Gauges & Senders
The FOZMULA range of engine monitoring instrumentation are reliable cost effective gauges
for use with 10 - 180Ω resistance match senders.
Incorporating integral back lighting, Fozmula gauges monitor oil temperature and pressure,
water temperature, battery volts and fuel level. Additionally, we offer tachos, hours run meters and speedos to complete the range.
PART NUMBER VOLTAGE DESCRIPTION
12V Oil Pressure 0-10 Bar
24V Oil Pressure 0-10 Bar
12V Oil Pressure 0 - 5 bar
24V Oil Pressure 0 - 5 bar
12V Water Temp, 40 -120°C
24V Water Temp, 40 -120°C
12V Oil Temp, 50 - 150°C
24V Oil Temp, 50 - 150°C
12/24 Ammeter, 50-0-50
12/24 Ammeter, 60-0-60
12V Voltmeter
24V Voltmeter
12V Fuel Level
24V Fuel Level
Gauges specification
Construction: Electrical:
Casing: Steel zinc plated and passivated Supply voltage: 12VDC (8/16VDC) or 24VDC (16-32VDC)
Window: Glass Resistance match: Linear 10 - 180Ω
Bezel: Matt black Connections: M4 x 0.7 studs and 6.3mm spades
Accuracy
Tolerance: Oil pressure, oil and water temp -±5% of the full scale value @ 25ºC ±5ºC
46
Gauges and Sensors
Spiral Gauges & Caps
The KELCH series of contents gauges, caps and dipsticks are designed for use on metal and plastic
storage tanks as used in the off-highway, lawn care, marine and generator set markets. The gauge
mechanism is simple and trouble free for long life and
reliability in service. The caps have the same head configuration as the gauges and both can be cus-
tomised to include special dial printing, vent styles and material colours.
Further options for the caps include lanyards and custom printing, and for the gauges, the spiral and
frame in alternative materials and limited spiral twisting for long filler necks.
Utility 175 Series Gauge
Fits all 1.3/4" buttress threads 6 tpi
Plastic caps in K100 Nylon 6 Copolymer
For use on plastic tanks
Lengths from 5" - 23" in 1/4" increments
Fits welded adaptor G/MP2
Guardian 225 Series Cap & Gauge
Fits all 2.1/4" buttress thread necks
Plastic caps in K100 Nylon 6 Copolymer
Gauge lengths from 5" - 23" in
1/4” increments
Guardian design for added gauge
protection
For use on plastic tanks
Fits welded adaptor G/MP5
Suregrip 225 Series Cap & Gauge
Fits all 2.1/4" buttress thread (5 tpi)
necks
Plastic caps in K100 Nylon 6 Copolymer
Gauge lengths from 5" - 23" in 1/4”
increments
For use on plastic tanks
Fits welded adaptor G/MP5
Utility 228 Series Cap & Gauge
Fits all 2. 9/32" quarter turn bayonet type
filler necks
Plastic caps in K100 Nylon 6 Copolymer
For use on metal tanks
Gauge lengths from 5" - 23" in 1/4"
increments
Fits welded adaptor G/MP6
Positive stop (cannot over tighten)
Guardian 228 Series Cap & Gauge
Fits all 2. 9/32" quarter turn bayonet type
filler necks
Plastic caps in K100 Nylon 6 Copolymer
Gauge lengths from 5" - 23" in 1/4” incre-
ments
Guardian design for added gauge protection
Fits welded adaptor G/MP6
Positive stop (cannot over tighten)
Remote Series of Gauges
Mounting via grommet or 1" - 11.5 NPSM thread with
O-ring
Plastic caps in K100 Nylon 6 Copolymer
Lengths of 5" - 23" in 1/4” increments
Permanent mount for added security
Automotive style indicator
Low profile & compact
For use on metal or plastic tanks
TIPSTM 350 Tank Inversion Protection
System
Fits all 2.1/4" or 3.1/2” buttress thread (5 tpi)
necks
Meets ANSI spec. Z130.1 1986 for rollover
protection
Minimises leakage when tank inverted
(35o angle or more)
Wide diamerter for easy fill
Available as cap only
For use on plastic tanks
47
NOTE
48
TERMS AND CONDITIONS OF SALE Definitions In these Terms and Conditions: The “Company” means Denver Petroleum Services Limited. The “Customer” means any person (natural or corporate), firm, unincorporated association or unincorporated body of persons or other entity, with whom the Company enters into a contract for the sale of goods (including any attendant provision of services) by the Company. The “Contract” means any such contract entered into between the Company and the Customer. The “Conditions” means these Terms and Conditions of Sale. The “Goods” means the goods to be sold by the Company pursuant to the Contract.
GENERAL All quotations and orders are subject to the following Conditions. All price lists are subject to change without notice. Orders become Contracts only upon accep-tance by the Company. The Conditions apply in preference to and supersede any terms and conditions referred to, offered or relied on by the Customer whether in negotiation or at any stage in the dealings between the Company and the Customer with reference to the Goods to which this Contract relates. Without prejudice to the generality of the foregoing the Company will not be bound by any standard or printed terms furnished by the Customer in any of its documents. The Company’s employees are not authorised to make representations concern-ing the Goods unless confirmed by the Company in writing and the Customer, in entering into the Contract, acknowledges that it does not rely on, and waives any claim for breach of, any such representation not so confirmed. Any description of the Goods has been given by way of identification only and the use of such description shall not constitute a sale by description. Any sample shown to the Customer was shown and inspected to enable the Customer to assess the quality of the Goods, and not to constitute a sale by sample. FORCE MAJEURE Orders are accepted by the Company under the condition that the Company is not to be liable for losses, detentions or delays occasioned by accident, strikes, fires affecting the Company’s operations or the operations of the Company’s suppliers or any other causes beyond the Company’s control and no damages for delay in delivery will be allowed. TIME OF DELIVERY Delivery dates are approximate only and the Company shall not be liable for any delay in delivery of the Goods howsoever caused. Time for delivery shall not be of the essence unless previously agreed by the Company in writing. The com-pany can deliver the Goods in advance of the quoted delivery date on giving reasonable notice to the Customer. WARRANTY AND EXCLUSION All Goods manufactured by the Company are guaranteed against defects in material and workmanship. No guarantee is made against corrosion, erosion or chemical attack. All metals and resilient synthetics are guaranteed to be of the material specified. There is no representation, warranty, condition or collateral agreement, express or implied, statutory or otherwise, in relation to or in any way affecting the Goods sold or the rights of the parties supported by this Con-tract, other than as herein contained. This warranty does not apply to Goods manufactured by others. Claims of incorrect or defective material or workmanship must be notified to the Company in writing within ten days from receipt of said material failing which the Goods are deemed to be in good condition. The Company then has the option of re-inspection at the Customer’s premises or the Company’s own before allowing or rejecting the Customer’s claim. If the fault lies with the Company, the Company shall, at its option, either replace or repair the defective Goods in question at its own cost and expense. Where the Company provides attendant services and such services are defectively performed, then provided the Company receives written notice of the same within the ten days period referred to above, the Company will re-perform the same services at its own cost and expense. No material may be returned without first obtaining written permission from the Company. If the fault lies with the Customer then the Company reserves the right to recover the cost of inspection and freight incurred by the Company Defects that do not impair satisfactory service shall not be a cause for rejections. Notwithstanding anything to the contrary the above represents the Customer’s sole remedy, and the Company’s sole liability for defective Goods and the conse-quences thereof whether under Contract, delict (including negligence), statute or at law. To the extent in conflict with the foregoing all implied terms, conditions, warranties and representations, statutory or otherwise,
as to (i) correspondence of the Goods to any description or (ii) the satisfactory quality of the Goods of (iii) the fitness of the goods for any purpose (whether made known to the Company or not) are excluded from the Contract to the maximum extent permissible by law. The Company will not assume any responsibility, expense or liability for repairs or alterations to Goods without the Company’s prior written consent. Neither party shall be liable to the other for any consequential or indirect loss including but without limitation, loss of revenue, loss of profit, business interruption or delay related loss howsoever caused and regardless of negligence or other breach of duty. These provisions will survive expiry or termination of the Contract. SHIPMENTS All prices quoted are ex works unless otherwise indicated in the Company’s quotation. The Company shall retain title to and hereby reserves the right to dispose of the Goods until full payment of the price of the Goods has been re-ceived. The Company’s responsibility for loss or damage to the Goods ceases with the collection of Goods in good order by transportation companies at which point risk in the Goods shall be the Customer’s responsibility. Delivery is not guaranteed at or to the destination. Claims for shortage or damage in transit must be made by the Customer against the carrier. In the absence of definite shipping instructions the Company reserves the right to ship all material upon completion by any public carrier, which the Company deems satisfactory. ADDITIONAL CHARGES Additional charges will be made to cover the cost of unusual packing delivery, engineering, servicing, overtime work, taxes, financing or any cost element not included in the Company’s price. In case of refusal or inability of Customer to accept any shipment in accordance with the terms of this order, or Contract, the Customer shall be held liable for freight, express, storage, extra cost or handling and other expenses that may be incurred thereby. Should the Customer’s financial standing become unsatisfac-tory to the company, cash payment or satisfactory security may be demanded by the Company and the Customer will comply with such demands. TERMS OF PAYMENT Terms are Nett monthly from date of invoice unless otherwise indicated in the Company’s quotation. The Company reserves the right to increase quoted prices if the cost of materials and third party supplies escalates. Where payment is overdue by more than 30 days, the company shall be entitled to charge interest on the amount due from time to time from the date of invoice to the date of payment at the rate of 4 per cent over the base lending rate of the Zenith Bank Plc. in force from time to time. OTHERS Charges made for tools, fixtures, etc. are a partial charge and do not convey ownership or the right to remove them from the Company’s premises. Neither the Customer nor the company shall be bound by any variation, waiver of, or addition to these Conditions except as agreed by both parties in writing and signed on their behalf. Headings in these Conditions are for ease of reference only and shall not affect their construction or interpretation. The Contract shall be governed by the laws of Nigeria.
49
By Telephone +234 1 7916760, 4795390, 4716355, 08034770662
By E-mail
By Web
www.denverpetroleum.com
How to get to us :
50
DENVER PETROLEUM SERVICES LTD. 380, Ikorodu Road, Maryland Ikeja, Lagos Nigeria
Tel : +234 1 7916760, 4795390, 4716355, 08034770662
E-mail : [email protected]
Website : www.denverpetroleum.com