All critical components in a 20ft-sized container IT racks, cooling system, fire suppression, UPS, etc. Tier3 level data center with Japan Quality Full automated local & remote operation Low pPUE: 1.17 (annual average), Low OPEX Applicable to various environment while realizing power efficiency 10kW per IT Rack, suited for Cloud, IoT, Big Data, HPC platform Ultimate utilization of space In-direct outside air cooling High Density IT Load Easy to scale, offering the best ROI in the shortest amount of time Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’ s over 20 years of data center operation experience Purpose-Built Eco Modular Data Center Platform Solution Pre-configured facility for

Upload: others

Post on 13-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Packed with IIJ’s over 20 years of data center operation ... · Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’s over 20 years of data center operation

All critical components in a 20ft-sized containerIT racks, cooling system, fire suppression, UPS, etc.Tier3 level data center with Japan QualityFull automated local & remote operation

Low pPUE: 1.17 (annual average), Low OPEXApplicable to various environment while realizing power efficiency

10kW per IT Rack, suited for Cloud, IoT, Big Data, HPC platformUltimate utilization of space

In-direct outside air cooling

High Density IT Load

● Easy to scale, offering the best ROI in the shortest amount of time●

Connecting Modular Architecture

fast, simple & easy deployment

Packed with IIJ’s over 20 years of data center operation experience

Purpose-Built Eco Modular Data Center Platform Solution

Pre-configured facility for

Page 2: Packed with IIJ’s over 20 years of data center operation ... · Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’s over 20 years of data center operation

COOLING BLOCK

RAISED FLOOR

IT RACK

All critical components in a 20ft-sized container

Fully assembled in Japan

Easy Deployment

Onsite installation completes within just a few daysConstruct a modular data center with minimum cost

Pre-fabricated at Factory Short Term Construction

co-IZmo Smart Manager“co-ISM”

Full automated local &remote control of modular

components

ModularData Center

Custom Design

Manufacture Assemble

Transportation

Onsite installation

Design Construction

BuildingData Center

Four Months

Over 12 Months

*construction period vary depending on multiple factors

・ 4 IT Racks ・ Cooling Block (40kW)

IT Module (Standard)

・ 4 IT Racks ・ Cooling Block (40kW)

IT Module (Standard)

・ UPS(N+1)・ Fire suppression system・Portal

UPS Module・ 8 IT Racks IT Module (Double)

Page 3: Packed with IIJ’s over 20 years of data center operation ... · Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’s over 20 years of data center operation

Free cooling architecture maximizes cooling efficiency, giving greater advantage in lowering OPEX

Energy Saving In-direct Outside Air Cooling System

HOT AREAIT RACKCOLD AREAFAN

OUTSIDEAIR

HEATEXCHANGER

COMPRESSOREXHAUST HEAT

Low PUE = 1.17 (annual average)

I T

Cooling etc.

I T

Cooling etc.

40% downCO2 Emission/Electricity Cost

Connecting Modular Architecture

Modularity allows to adopt new technologies with the easy to replace feature

Easy to expand “block-like” container

Expand/Replace

Accommodate and deploy the latest high-density equipment and realize space efficiency both at the same time

High Density IT Load

Building-type DC

co-IZmo/IHIGH DENSITY RACKS

Optimal for IoT, Cloud and Big Data Era

Applicable to various environmentRealize power efficiency even in cold, hot and dusty climates and environments

The cooling module automatically selects its operation mode by temperature and humidity

Uses outside air as much as possible to reduce power consumption

HybridMode

Indirect Outside Air+Refrigerating

IndirectOutside Air Mode

Winter Season

RefrigeratingMachine ModeSummer Season

Building typeData CenterPUE=2

co-IZmo/IPUE=1.17

Energy cost reduction

Page 4: Packed with IIJ’s over 20 years of data center operation ... · Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’s over 20 years of data center operation

Japan’s 1st & Largest Modular Data Center using outside air cooling

Opened in April 2011 in Matsue-city for IIJ’s cloud service “IIJ GIO” as a Tier3 level data center

I I J - DC122 - 0002

For inquiriesInternet Initiative Japan Inc.2-10-2 Fujimi, Chiyoda-ku, Tokyo 102-0071, JapanTEL : +81-3-5205-4466E-mail : [email protected] URL:http://www.iij.ad.jp/DC/en

*The information on this sheet is subject to change without prior notice.

Matsue

Tokyo

Front view of Module DC Park

Security Fences & Gate Electrical equipment Emergency power generators

Outside view of IT Module High Density IT Racks

Electrical Equipment

Cooling Module

IT Module

Security Gate

Generator

SurroundingFences

Page 5: Packed with IIJ’s over 20 years of data center operation ... · Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’s over 20 years of data center operation

Travelled over 9,000 km

Estimated annual average pPUE of 1.2 in humid environment

Lao PDR Energy Efficient Datacenter Project

Serving Clients Needs Around the World

co-IZmo/I Case Study

・ World-class energy efficiency & low CO2 emission datacenter ・ Fully fabricated cloud computing platform

Russian private enterprise・ Operating in Minus 30°C environment ・ IIJ’s knowledge and quality for DC operation highly valued by customer

Page 6: Packed with IIJ’s over 20 years of data center operation ... · Connecting Modular Architecture fast, simple & easy deployment Packed with IIJ’s over 20 years of data center operation

Deployment Examples

Specifications

Responding to wide-ranging needs

co-IZmo/I Specifications

IT Module (Standard) Option

・Cold District Specification: ‐30℃

・Dual Input ・Three -phase, four-wire 380VAC to 420VAC 50Hz/60Hz

2438W x 6058L x 2922H mmExterior Measurement

Approx. 9t (Excluding IT Equipment)

1,200kgf/m2

Time of operation: ‐15℃ to +43℃

5%RH to 90%RH

Three -phase, three-wire 200VAC/220VAC 50Hz/60Hz

10KW (Maximum Actual Power)

Horizontal acceleration 1.0GSagging straight acceleration 0.5G

Weight

Withstand Load

Placement Requirement

Strength / Earthquake-resistant

Temperature

Humidity

Power

Input(Single)

Per IT Rack

Number

Installation Load

Size

4 IT racks

800kg per IT rack

560W x 1200D x 2100H mm (44U) , EIA standard (19inch)

IT Rack

Cooling System

Cooling Capacity

Configuration

Design

Temperature Range

40kW・12,000m /h per unit 3

N+1

Indirect Outside Air Cooling

18℃ to 28℃ (Cold Area)Temporary permissible temperature range: 5℃ to 40℃

Fire Alarm Systems & Fire Extinguisher ・N2 Gas Fire Suppression System

Door sensor, Physical lock, Internal security camera ・Electricity lock, Enter/Exit control, Intrusion detection

Fire System

Security

Scale

Use Case

Number of IT Racks & Density per IT Rack

Ground Area

Number of Cooling Block

Others

11m × 22m = 242m2 28m × 34m = 952m2 34m × 43m = 1462m2

Disaster Recovery Enterprise Private CloudCommercial DatacenterEnterprise Public Cloud

12 IT Rack*10kW 48 IT Rack*10kW 96 IT Rack*10kW

40kW*4 (N+1)

Generator, UPS, Fire Suppression (Fire Extinguisher, Fire Detection, N2 Gas Suppression), Security (CCTV, Access Control, Fence, Anti-Passback), Management System “co-ISM”

40kW*14 (N+1) 40kW*28 (N+1)