Actuation Solutions and Systems for theWorld’s Most Challenging Environments

• Engineering and Design• Assembly• Programming• Factory & Site Acceptance Testing• Worldwide Industrial Certifications

Panel SolutionsCustom Control Panels and Systems

Page 2: Panel Solutions - Cowan Dynamics...2016/01/29  · • Layout Diagrams • Interconnection Diagrams • Operating and Maintenance Manuals • Assembly of Enclosures • Integration

Service and support www.cowandynamics.comToll-free: 855 341 3415 [email protected]

PANEL SOLUTIONS

PBX SERIES – 250 psi Dual Stage High Output Pneumatic Booster

Engineering & Design Assembly & Integration

• Components Selection

• Electrical Schematics

• Layout Diagrams

• Interconnection Diagrams

• Operating and Maintenance Manuals

• Assembly of Enclosures

• Integration and Wiring of Components

From small simple local control panels to large multi-cabinet PLC based systems. Based on the logic provided by the end user.

29 1

/4"

41.25" 12.40"

DRUM P2-02 ISOLATION201/9 SWITCH VALVE KP-201 BYPASS VALVE

201/8DRUM P-201 ISOLATION

201/1

PERMISSIVEMET

POWERLCP-1

PERMISSIVEBYPASS

OFF ON

MIDPOINTOFF ON LAMP TEST BYPASS

OFF ONPERMISSIVE

MET

OPENED PERMISSIVE METP-202

OPEN AT P-202

CLOSED P-202 TO MID

CLOSE P-202 TO BYPASS

STOP RESTART

AT MID

MID TO P-201

MID TO P-202

AT P-201

P-201 TO BYPASS

P-201 TO MID

AT BYPASS

BYPASS TO P-202

BYPASS TO P-201

STOP

OPEN

CLOSED

CLOSE

STOP

PERMISSIVE METP-201 OPENED

OPEN

CLOSED

CLOSE

STOP

OPENED

M25

M40

LOCAL REMOTE

M40 M40 M40 M40 M40 M40 M40 M40 M40

M40 M40 M40 M40 M40 M40 M40 M40 M40

M25 M25 M25 M25 M25 M25 M25

35"

23"

Ground bar

1 1/2 x 3" gray wire duct

1 1/2 x 3" gray wire duct

LTEST1

LTEST2

LTEST3

LTEST4

1 1

/2 x

3" g

ray w

ire d

uct

1 1

/2 x

3" g

ray w

ire d

uct

P2022 P2011 RUNPBYP1BYP CW

PERMA1

PERMA2 PERMA4

PERMA5 TCCW

TCW

PTOP202

PTOP201

P2021 MID NOPOSP2012 PBYP2 CCW

PERMA3

PERMB1 PERMB3

PERMB4PERMB2

PERMB5

TB3 TB4 TB5 TB6

PSWeidmuller8951350000

REM1201/9OP

201/1OP

REM3 REM5

REM2 REM4

1 1/2 x 3" gray wire duct

TB

1T

B2

TB

7

Hammond#FLHTF400A230

400W/240V

HT

LTEST124V

PB11: "LAMP TEST"

LTEST224V

B

PL4: "POWER LCP-1"

LTEST324V

LTEST424V

TB2 TB2

L N

M

PS: Power supply100-240Vac:24Vdc @ 7.5A

220Vac 1 phase customer supply(437VA capacity, fused at source)

M

1 2

L1-2 N-2

24V24V

L1-2 N-2 Gnd

24V M

24V

24V

M

M

M

M

M

301

301

301

301

Copperground bar

TB714

TB724

TB764

TB713

TB723

TB763

24V

24V

24V

24V

24V

24V

24Vdc supply to LCP-2

24Vdc supply to LCP-3

24Vdc supply to LCP-4

REM124V

PB16: "LOCAL/REMOTE"

REM224V

REM324V

REM424V

24V M

M

M

M

302

302

302

302

47

48TB3

TB3 Local panel"In Remote"contact to DCS

303

304

REM524V

M302

M

M

M

Switch valve local control panelLCP-1

-continued-DCS

37"KP-201 MOV Ready" contact

46

47

40

41

42

43

44

45

48

"KP-201 AT P-202" contact

"KP-201 AT MID" contact

"KP-201 AT BYPASS" contact

"KP-201 AT P-201" contact

TB3

Spare

Spare

Spare

Spare

Spare

Spare

KP-201AUMA Actuator**

1

2

3

5

6

9

10

11

12

4

Make atP202

Make atMID

Make atBYPASS

Make atP201

Switch valve position switchesKP-201

17

19

13

15

16

25

20

21

23

24

27

29

30

7

8

28

14

18

22

26

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

Spare

4 Close

5

Stop(2)6

Open

7 0v U1

V1

W1

E3 ph

ase

supp

ly 380Vac3 phasesupply

1 24Vdc

2 0v

3 Mode

Jum

p int

erna

lly

14 NC

16 COMK1: Fault

39

38

49

50

56

57

51

52

53

54

55

58

59

60

"Remote Bypass to P-202" contact

"Remote Stop" contact

"Remote Mid to P-201" contact

"Remote P-202 to Mid" contact

"Remote Bypass to P-201" contact

"Remote P-201 to Bypass" contact

"Remote P-201 to Mid" contact

"Remote P-202 to Bypass" contact

"Remote Mid to P-202" contact

66

61

62

63

64

65

Spare

Spare

68

67

PB16:"LOCAL/REMOTE"

Local panel "In Remote" contact

70

69

Spare

72

71

(1) Programmed for(2) Programmed for N.C.

24 (-)

23 (+) ANOUT1(Positionfeedback)Shielded

cable

KP-201 "Position feedback" 4-20masignal (500 ohms max.)

ShieldedcableSignal Ground

Spare

Spare

Spare

32

33

31

36

35

3476

73

74

75

78

77

Page 3: Panel Solutions - Cowan Dynamics...2016/01/29  · • Layout Diagrams • Interconnection Diagrams • Operating and Maintenance Manuals • Assembly of Enclosures • Integration

Service and support www.cowandynamics.comToll-free: 855 341 3415 [email protected]

PANEL SOLUTIONS

PBX SERIES – 250 psi Dual Stage High Output Pneumatic Booster

• We have a dedicated team for performing or assisting with FAT and SAT

• Worldwide Industrial Certifications:

• PLC/HMI Program Development - All major brands supported

• Custom development of computer screens for operator interface

• Database Development

• Report Generation Software Development

• DCS Software Development

Programming & Software Development

Testing & Certification

Page 4: Panel Solutions - Cowan Dynamics...2016/01/29  · • Layout Diagrams • Interconnection Diagrams • Operating and Maintenance Manuals • Assembly of Enclosures • Integration

Actuation Solutions and Systems for theWorld’s Most Challenging Environments

Service and support www.cowandynamics.comToll-free: 855 341 3415 [email protected]

PANEL SOLUTIONSPublished January 29, 2016

Related materials Visit our website to download or request a printed catalogue.

www.cowandynamics.com

Solutions Include:

Valve Actuators

Fail-Safe Systems

Digital Process Control Panels

Pneumatic Process Control Panels

For sales and technical information,Contact us at:

Head Office/Factory:6194 Notre Dame WestMontreal, Quebec H4C 1V4TOLL-FREE: 855-341-3415 Sales Office:211 Watline Ave, Unit 205Mississauga, Ontario L4Z 1P3T: 905-829-2910TOLL-FREE: [email protected]

/cowandynamics

/company/cowan-dynamics

/cowandynamics