performance platinum hybrid electric is the most efficient ... · performance platinum hybrid 40,...
TRANSCRIPT
04/20 FORM NO. THD-PPEH5-30
PERFORMANCE PLATINUMHybrid
40, 50, 65 and 80-Gallon Capacities
208-240 Volt / 1 PH Electric
30 Amps
PERFORMANCE PLATINUM™ Hybrid Electric is the most efficient water heater available
Efficiency High 3.75 - 4.0 UEF reduces
operating cost
ENERGY STAR® rated
Performance Delivers hot water faster than most
standard electric water heaters – 60-87 gallons first-hour delivery, depending on model
Ambient operating range: 37-145° F is widest in class, offering more days of HP operation annually; designed to meet Northern Climate Spec (Tier 4)
Easy Installation Easy access side connections
Quick access to electrical junction box
Easily replaces a standard electric water heater
Integration Electronic control for easy
temperature adjustment and mode management
Audible alarm for service alerts
Integrated EcoNet® WiFi- connected* technology (2.4 GHz only) and free mobile app gives users control over water systems, allowing for customizable temperature, vacation settings, energy savings and system monitoring at home or away. Visit Rheem.com/EcoNetConnect
Operation Modes Energy Saver
Heat Pump
High Demand
Electric
Vacation/Away: 2-28 days (or placed on hold indefinitely)
Plus… Premium grade anode rod with
resistor extends the life of the tank
3/4" NPT water inlet and outlet; 3/4" condensate drain connections
Incoloy stainless steel resistor elements
Dry-fire protection
Easy access, top mounted washable air filter
2" Non-CFC foam insulation
Enhanced flow brass drain valve
Temperature and pressure relief valve installed
Low lead compliant
Warranty 10-Year limited warranty for tank
and parts, 1-year full in-home labor warranty
See Residential Warranty Certificate for complete information
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.
LEED Points = 3
* WiFi broadband internet connection required
See specifications chart on back.
Fuel Type Desc.
NominalGallonCap.
RatedGallonCap.
Model Number
ModelVariant
ElectricBreaker
Size
UniformEnergyFactor(UEF)
EstimatedYearly
Energy CostElementWattage
CompressorBtu/H
SoundLevel(dBa)
First Hr. RatingG.P.H.
Recovery in G.P.H.
90° F Rise
TankHeight
ADiam.
B
Ht. to Cold Inlet & Drain Valve
Ht. toHot
Outlet& T&P
Unit Wt.
(LBS.)
Approx.Ship Wt.(LBS.)
30 AMPS Electric Tall 40 36 XE40T10H45U0 700474 30 3.75 $104 4,500 4200 49 60 27 62-5/16" 20-1/4" 3-5/8" 39-5/8" 157 174
Electric Tall 50 45 XE50T10H45U0 700488 30 3.75 $104 4,500 4200 49 67 27 61-3/4" 22-1/4" 3-5/8" 39-5/8" 178 218
Electric Tall 65 59 XE65T10H45U0 700489 30 3.85 $155 4,500 4200 49 75 27 64-3/16" 24-1/4" 3-7/8" 42-3/8" 225 262
Electric Tall 80 72 XE80T10H45U0 700473 30 4.00 $149 4,500 4200 49 87 27 74-3/16" 24-1/4" 3-7/8" 42-3/8" 244 281
Hybrid Specifications
2
DESCRIPTION DIMENSIONS (SHOWN IN INCHES)
NOMINALGALLON
CAPACITYMODEL
NUMBER A B C D E F G H I J
40 XE40T10H45U0 62-5/16 20-1/4 47 3-5/8 39-5/8 23-3/8 20-1/2 78-7/8 22-3/8 23-1/4
50 XE50T10H45U0 61-3/4 22-1/4 47 3-5/8 39-5/8 25-3/8 22-1/2 78-5/8 24-3/8 25-9/16
65 XE65T10H45U0 64-3/16 24-1/4 49 3-7/8 42-3/8 27-1/2 24-5/8 81-1/8 26-1/2 27-3/8
80 XE80T10H45U0 74-3/16 24-1/4 59 3-7/8 52-3/8 27-1/2 24-5/8 91 26-1/2 27-3/8
A
CE
DD
B
F
G
2” Clearance Neededfor T&P Release
H
I
J
Hybrid Water Heater Installation Guidelines to Provide Optimal Efficiency
3
04/20 FORM NO. THD-PPEH5-30
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com
Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10').Requirements: No additional ventilation needed.
Heater: Not Ducted
24”
12” Max
Air exhaust
Door
.75”
Room size: Any size roomRequirements: No additional ventilation needed.
Heater: Ducted with inlet AND outlet ductRoom size: Any size roomRequirements: Air gap under door equal to 18 in2 (0.75” clearance)
Heater: Ducted with inlet OR outlet duct
Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10').Requirements: Full louvered door OR two louvers top and bottom. See below.
Heater: Not Ducted
24”.75”
Room: Small ClosetRequirements: * Air gap under door equal to 18 in2 (0.75” clearance). * Louver must be located the same height on door as the air exhaust on heater. * Heater air exhaust must be positioned towards louver within one foot of door.
Heater: Not ducted