25 NEW LOTS AVE COGENERATION SYSTEM PLAZA RESIDENCES Ƒ MECHANICAL SYSTEMS BC 1704.16 Ƒ HEATING SYSTEMS BC 1704.25 Ƒ FIRE-RESISTANT PENETRATIONS AND JOINTS BC 1704.27 Ƒ ENERGY CODE COMPLIANCE INSPECTION BC 110.3.5 Ƒ HVAC & SERVICE WATER HEATING EQUIPMENT IIB3 Ƒ HVAC & SERVICE WATER HEATING CONTROLS IIB4 Ƒ DUCT PLENUM AND PIPING INSULATION & SEALING IIB5 Ƒ MAINTENANCE INFORMATION IID1 SPECIAL INSPECTIONS/PROGRESS (TR-1) ENERGY CODE COMPLIANCE INSPECTIONS (TR-8)

Upload: others

Post on 12-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

25 NEW LOTS AVECOGENERATION SYSTEM

PLAZA RESIDENCES

□ MECHANICAL SYSTEMS BC 1704.16

□ HEATING SYSTEMS BC 1704.25

□ FIRE-RESISTANT PENETRATIONS AND JOINTS BC 1704.27

□ ENERGY CODE COMPLIANCE INSPECTION BC 110.3.5

□ HVAC & SERVICE WATER HEATING EQUIPMENT IIB3

□ HVAC & SERVICE WATER HEATING CONTROLS IIB4

□ DUCT PLENUM AND PIPING INSULATION & SEALING IIB5

□ MAINTENANCE INFORMATION IID1

SPECIAL INSPECTIONS/PROGRESS (TR-1) ENERGY CODE COMPLIANCE INSPECTIONS (TR-8)

Page 2: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

COGENERATION MECHANICAL FLOW DIAGRAM

Page 3: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

CELLAR MECHANICAL PIPING LAYOUT CELLAR MECHANICAL FLUE LAYOUT

Page 4: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

CELLAR HOT AIR EXHAUST LAYOUT

Page 5: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

COGENERATION DUCT WORK DETAIL

COGENERATION FLUE DETAIL COGENERATION MECHANICAL CONNECTION DETAIL

RADIATOR CONNECTION DETAIL

Page 6: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

CELLAR PLUMBING LAYOUT

CELLAR GAS PIPING LAYOUT

Page 7: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

STORAGE TANK CONNECTION DETAIL

COGENERATION GAS CONNECTION DIAGRAM

COGENERATION GAS RISER DIAGRAM

Page 8: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

COGENERATION CELLAR ELECTRICAL PARTIAL PLAN-1

Page 9: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

COGENERATION CELLAR ELECTRICAL PARTIAL PLAN-2

Page 10: PLAZA RESIDENCES 25 NEW LOTS AVE COGENERATION …...plaza residences mechanical systems bc 1704.16 heating systems bc 1704.25 fire-resistant penetrations and joints bc 1704.27 energy

COGENERATION ELECTRICAL ONE LINE DIAGRAM