presentation dma building code adsg fqm 2011-04-20
TRANSCRIPT
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
1/26
Abu Dhabi’s new Building Codes - underpinning
sustainable develo ment
ADSG FQM 2011
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
2/26
The DMA
4 entities, DMA, Abu Dhabi
, ,
Western Region Municipality Staff of 4000+
,
and regulations.
Municipalities are the.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
3/26
DMA’s Vision & Mission
Vision
“
n a vance mun c pa sys em a ena es sus a na e
development and enhances quality of living for the Emirate of Abu Dhabi.”
Mission
“To achieve the Abu Dhabi Government’s objective of providingdistinctive municipal services that enhance the quality of living
of all residents through coordination, oversight and monitoring of
the Abu Dhabi Municipalities and Municipal Councils”
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
4/26
In 2006 the government underwent a restructure to
create a decentralized model…..
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
5/26
of specialist departments with specific functions…
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
6/26
DMA is providing the integrated framework to
enable the development of sustainable cities with anenhanced quality of l ife…
Commitment towards creating cities
that are economically, socially and ecologically
sustainable. Collaborate with other government agencies.
.
Develop municipal governance frameworks.
Support the Municipal System deliver quality
services
Developing relationships with the public,
private & ‘third’ sectors
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
7/26
through an advanced Municipal System…
“ By integrating the regulations and
olicies of all overnment a encies
…the DMA can demonstrate to theworld that the Emirate has a
comprehensive regulatory framework
in place befitting a 21st Century
economy”
HE Ahmed Shareef-DMA Undersecretary-
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
8/26
and the Municipal Code regulatory framework
Main Responsibility for Regulation
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
9/26
Building codes…regulating sustainability in the
building & construction sector…IBC- International Building Code
-
IPC-International Plumbing Code
-
IMC-International Mechanical Code
-
IPSDC-International Private Sewage Disposal
Code
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
10/26
IBC- International Building Code…improving
quality of l ife and quality of construction by
addressing..
• Durability
• Life safety & accessibi lity
• Interior environment (ventilation & daylighting)
• Structural design & inspection
• Materials-durabilit and combustibilit & ecolo ical impact (cement replacement)
• Flood resistance
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
11/26
IECC-International Energy Conservation Code….
Governance
• New construction or minor renovation-triggers code.
• All items available ‘off the shelf ’.
• Energy modeling mandatory.
• Energy densi ty targets- UN targets for extremely hot climates
(Kuwait, Riyadh, Calcutta, Hong Kong) of 132Kwh/m2/pa for
residential & 96Kwh/m2/ a for commercial are achievable.
• Commissioning requirements include commissioning plan,
systems balancing report, preliminary and final commissioning
reports, as- built drawings & maintenance manuals.
• x ens ve me er ng requ remen s or ase u ng an
tenancies.
• Options exist for 3% renewable energy OR greater energy
effic iency IECC-
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
12/26
International Energy Conservation Code….
Perimeter
• Both a prescriptive and performance routes- code
prescribes maximum 30% glazing or follow ASHRAE 90.1
• Prescriptive U values -walls 0.33, roof 0.22, fenestration
system 2.1(including frame).
• Solar Reflectance Index -64 for the roof.
• ro ec on ac or e erm nes enes ra on va ues.
The greater the projection the higher the SHGC No projection
=0.25, maximum projection=0.4
• Air leakage- Maximum7.2m3/hr/m2 at 70Pa.
• Continuous air barrier.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
13/26
International Energy Conservation Code….
ec an ca ys ems
• Right-sizing - submit calculations supporting plantand equipment selection.
• COP - air and water cooled equipment ranging from
3.4 for small air cooled units to 6 for water cooledchillers greater than 600TR
• Maximum allowable duct leakage.
• Dynamic systems such as using VAV & VSDmandatory
• Demand controlled ventilation DCV for s acesgreater than 50m2
• Set point 24 deg C with RH 50%
• -
wheel, condensate, waste heat etc.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
14/26
International Energy Conservation Code….
Lighting systems
•75% high efficacy l ighting (60w/l)
•Fully controlled -including specifications for holiday mode.
•Lighting densities -internally and externally.
•Day-lighting control zones (max 250m2).
• Automatic controls for day-lighting.
•Occupancy sensors.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
15/26
International Mechanical Code …improving
,the ozone layer through…
• Prescribed minimum outdoor air %
• Minimum ventilation rates to protect
occupant health,
• Design of ductwork to promote efficiency
,
• Zone and air distr ibution effectiveness,
• Minimum car park ventilation rates,
• Exhaust s stems,
• Refrigerant classifications,
• Thermal storage & ground source heat
pump systems
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
16/26
International Plumbing Code….water (and
therefore energy) conservation through…
• Fittings & fixtures flow rates
• Temperature regulators,
• Condensate harvesting,
• Metering
• as ewa er re-use
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
17/26
International Plumbing Code…Fixtures & Fittings
• Washbasin-6lm
• ower ea - m
• Water closet-dual flush with small flush=3litres
Residential Consumption –Estimate of Internal Use
Minimum bathing-1x5 minute shower/day= 30
litres
Minimum toilet flushing= 15 litres=, -
= 140 -250 litres/day based on behavior
• .
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
18/26
International Fire Code… regulations for life
sa e y…
Regulates and safeguards hazards of fireor explosions resulting from the storage
or use of hazardous materials safet to
life and property, matters related to fire
suppression or alarm systems
and conditions affecting the safety of firefi hters and emer enc res onders.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
19/26
International Private Sewage Disposal Code..
Safe and sanitary installation of individual
sewa e dis osal s stems.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
20/26
International Fuel Gas Code- safe installation
of fuel gas systems
Addresses design and installation of fuel gas systemsand gas-fired appliances through requirements
em hasizin erformance.
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
21/26
..which ‘dovetail’ with the recently developed
n erna ona reen ons ruc on o e……..
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
22/26
The building codes have been developed in
collaboration with the relevant stakeholders…
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
23/26
which involves the alignment of process streams for
development and building permit approval…..
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
24/26
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
25/26
…and with worker health & safety heavily regulated
throu h the DMA’s EHSMS for the Buildin &Construction sector…
-
8/18/2019 Presentation DMA Building Code ADSG FQM 2011-04-20
26/26
Thank You