pressure - chevrier instruments...2016 version 1 pressure basco pressure gauges kv series • dry,...

26
www.chevrierinstruments.com 2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series Dry, accuracy Grade B (3-2-3) SS Case, brass fitting, glass lens SS chromed bezel KV401 KV404 KV501 KV504 KV601 KV604 KV101 1/8"npt 1/8"npt 1/8"npt 1/8"npt 1/4"npt 1/4"npt 1/4"npt 1/4"npt 1/4"npt Code Range 401/801 -30"hg/0/kPa 417/817 0/15 psi/kPa 420/820 0/30 psi/kPa 422/822 0/60 psi/kPa 423/826 0/100 psi/kPa 425/825 0/160 psi/kPa 426/826 0/200 psi/kPa 427/827 0/300 psi/kPa 429 0/500 psi/kPa 430 0/600 psi/kPa 432 0/1000 psi/kPa 433 0/1500 psi/kPa 435 0/2000 psi/kPa 436 0/3000 psi/kPa 438 0/5000 psi/kPa •Other ranges available on demand (or not listed) BASCO Pressure Gauges 760 Series Glycerin filled, accuracy, Grade B (3-2-3) SS Case, brass fitting, plastic lens SS chromed bezel 63 mm (2½" diameter) Fitting ¼” npt Restriction screw Code Range 401 -30"hg/0/kPa 406 -30"Hg/0/30 psi/kPa 417 0/15 psi/kPa 420 0/30 psi/kPa 422 0/60 psi/kPa 423 0/100 psi/kPa 425 0/160 psi/kPa 426 0/200 psi/kPa 427 0/300 psi/kPa 428 0/400 psi/kPa Code Range 429 0/500 psi/kPa 430 0/600 psi/kPa 432 0/1000 psi/kPa 433 0/1500 psi/kPa 435 0/2000 psi/kPa 436 0/3000 psi/kPa 438 0/5000 psi/kPa 439 0/6000 psi/kPa 441 0/10000 psi/kPa 442 0/15000 psi/kPa 761 + Code 764 + Code Diameter Code Clamp-Ring 39.5 mm 019087 50 mm 019089 63 mm 019091 Front Flange 63 mm Option-06/063 Rubber Boot 40 mm OGM-040N * 50 mm OGM-050N 63 mm OGM-063N 100 mm OGM-100N U Clamp 40 mm U40MM-12 50 mm U50MM 60 mm U63MM 764 761 KP744 DRY LIQUID FILLED Code 8xx 4xx Accessories for Series KV, KP and 760 To Order : MODEL + CODE MODEL To Order * Order of 250 units and more only KP744 + Code Code Range 801 -30"Hg/0 Vac/kPa 817 0/15 psi/kPa 820 0/30 psi/kPa 822 0/60 psi/kPa 823 0/100 psi/kPa 825 0/160 psi/kPa KP740 Series Glycerin filled, accuracy, Grade B (3-2-3), see 760 Series description 40mm (1 ½") diameter Fitting 1/8" npt To Order Other ranges on demand KP741 + Code

Upload: others

Post on 12-Oct-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 11

P R E S S U R E

BASCO Pressure GaugesKV Series• Dry,accuracyGradeB(3-2-3)• SSCase,brassfitting,glasslens• SSchromedbezel

KV401 KV404 KV501 KV504 KV601 KV604 KV101 1/8"npt 1/8"npt 1/8"npt 1/8"npt 1/4"npt 1/4"npt 1/4"npt 1/4"npt 1/4"npt Code Range 401/801 -30"hg/0/kPa417/817 0/15psi/kPa420/820 0/30psi/kPa422/822 0/60psi/kPa423/826 0/100psi/kPa425/825 0/160psi/kPa426/826 0/200psi/kPa427/827 0/300psi/kPa429 0/500psi/kPa430 0/600psi/kPa432 0/1000psi/kPa433 0/1500psi/kPa435 0/2000psi/kPa436 0/3000psi/kPa438 0/5000psi/kPa

•Otherrangesavailableondemand(ornotlisted)

BASCO Pressure Gauges760 Series• Glycerinfilled,accuracy,GradeB(3-2-3)• SSCase,brassfitting,plasticlens• SSchromedbezel• 63mm(2½"diameter)• Fitting¼”npt• Restrictionscrew

Code Range 401 -30"hg/0/kPa 406 -30"Hg/0/30psi/kPa 417 0/15psi/kPa 420 0/30psi/kPa 422 0/60psi/kPa 423 0/100psi/kPa 425 0/160psi/kPa 426 0/200psi/kPa 427 0/300psi/kPa 428 0/400psi/kPa

Code Range 429 0/500psi/kPa 430 0/600psi/kPa 432 0/1000psi/kPa 433 0/1500psi/kPa 435 0/2000psi/kPa 436 0/3000psi/kPa 438 0/5000psi/kPa 439 0/6000psi/kPa 441 0/10000psi/kPa 442 0/15000psi/kPa

761 + Code

764 + Code

Diameter Code Clamp-Ring 39.5mm 019087 50mm 019089 63mm 019091

Front Flange 63mm Option-06/063

Rubber Boot 40mm OGM-040N *50mm OGM-050N 63mm OGM-063N 100mm OGM-100NU Clamp 40mm U40MM-12 50mm U50MM 60mm U63MM

764 761

KP744

DRY

LIQUID

FILLED

Code 8xx4xx

Accessories for Series KV, KP and 760

To Order : MODEL + CODE

M O D E L

To Order

*Orderof250unitsandmoreonly

KP744 + Code

Code Range 801 -30"Hg/0Vac/kPa 817 0/15psi/kPa 820 0/30psi/kPa 822 0/60psi/kPa 823 0/100psi/kPa 825 0/160psi/kPa

KP740 Series• Glycerinfilled,accuracy,GradeB(3-2-3),

see760Seriesdescription• 40mm(1½")diameter• Fitting1/8"npt

To Order

Other ranges on demand

KP741 + Code

Page 2: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n22

P R E S S U R E

SISCO P/T PlugsKnown as P/T Plugs

Forpressureortemperaturetests• Novacuumlossat1000psi• Fortemperaturesfrom-40to1000°F• Forinjectingsubstancesduringproduction,

emptyingairorgases,measuringflows(hydronic),etc.

• Soldinboxesof20

Plugs Code npt Material Core Material Max Temp. Units/box BNO-125 1/8" Brass Nordel 350°F 36 BNE-250 ¼" Brass Neoprene 200°F 36 BNO-250 ¼" Brass Nordel 350°F 36 SSNE-250 ¼" SS304 Neoprene 200°F 36 SSNO-250 ¼" SS304 Nordel 350°F 36 BNO-500 ½" Brass Nordel 350°F 14 BNE-500 ½" Brass Neoprene 200°F 14 SSNO-500 ½" SS304 Nordel 350°F 14 SSNE-500 ½" SS304 Neoprene 200°F 14

Pressure & Temperature Test Plugs Accessories

Code npt Material Description PC-150 ¼" Plastic CapRetainer PC-063 3/8" Plastic CapRetainer PC-500 ½" Plastic CapRetainer BTX-250 ¼"M/F nptBrass Extension1¾" BNO-253 ¼"M/F nptBrass Extension3" BTX-500 ½"M/F Brass Extension1¾" GA-063 1/16" Inox Probe GA-125 1/8" Inox Probe GA-125S 1/8" Inox ShortProbe

HYETT Robust Membrane SealsSeries 42M/42M01• Processsidefittings¼to1½”npt• Manometersidefittings¼”or½”npt• Replaceablediaphragm2.5”diaSS316;options:

304,Monel,HastelloyCorB,Viton,Teflon,etc.• SteelorSSbase;options:HastelloyBorC,

Monel,Mylar,Teflon,PVC• Steelorsteel/SSring• Forpressuresfrom100to2500psi(model42HPfor5000psi)• Fittingforcleaning:¼”nptonmodel42M01 Code Description 42M-4A1A Allsteel,¼”mano,1”process 42M-4I2I AllSS,¼”mano,½”process 42M-4A1I Halfsteel/SS,¼”mano,1”process42M01-4A1A Allsteel,¼”mano,1”process SS-4-P SSstopper¼”npt 015 Gaugemountedonseal

BASCO Pressure Gauges BP750 Series• Liquidfilled,2%accuracyGradeB• SScase,brassfitting,plasticlens• SSchromedbezel• 50mm(2"diameter)• ¼or1/8”nptfitting

Code Range 401 -30"hg/0/kPa 417 0/15psi/kPa 420 0/30psi/kPa 422 0/60psi/kPa 423 0/100psi/kPa 425 0/160psi/kPa 426 0/200psi/kPa 427 0/300psi/kPa 428 0/400psi/kPa 429 0/500psi/kPa 430 0/600psi/kPa 432 0/1000psi/kPa 433 0/1500psi/kPa 435 0/2000psi/kPa 436 0/3000psi/kPa 438 0/5000psi/kPa 439 0/6000psi/kPa 441 0/10000psi/kPa 820 0/30psi/kPa 825 0/160psi/kPa 836 0/3000psi/kPa

BP751 + CodeOrder Code

MILJOCO GaugesP4598L SeriesThe Gauge for the ContractorGauge for commercial HVAC115 mm (4.5 inches) diameterDry, Accuracy ±1%. Grade 1ATheMiljocoP4598LContractor’sGaugemeetsorexceedstheindustryacceptedstandardsforcommercialHVACandbuildingtrades.

Thisinstrumentfeaturesastainlesssteelcaseandring,anduseshightemperaturesolderjointsonthetubeandsocket,allowingittobeusedonprocessfluidsupto93°C(200°F).• Case:brightlyfinishedstainlesssteel• Ring:stainlesssteel• Lens:acrylic• Dial:aluminum,whitefinishwithblackmarkings• Pointer:aluminum,black,adjustable• Movement:brasswithprecision-milledteeth• TubeandSocket:phosphor-bronzetube• Connection:1/4”NPTbottommount• Accuracy:±1%fullScale(ASMEB40.100Grade1A)• ProcessTemperature:-40to93°C(-40to200°F)• AmbientTemperature:-40to60°C(-40to140°F)

Option: Silicone dampening

Range Standards Specifications - Range PSI Dual Scale CodesCode Range Figures Division psi/kPa psi/Bar psi/piH2O001 -30”Hg/0 5 1 001K 001B 001F002 -30”Hg/0/15psi 10/5 2/1 002K 002B 002F003 -30”Hg/0/30psi 10/5 2/1 003K 003B 003F004 -30”Hg/0/60psi 10/10 1/1 004K 004B 004F005 -30”Hg/0/100psi 30/20 5/2 005K 005B 005F006 -30”Hg/0/150psi 30/20 5/2 006K 006B 006F008 -30”Hg/0/300psi 30/50 10/10 008K 008B 008F02 0/15psi 2 0,1 02K 02B 02F03 0/30psi 5 1 03K 03B 03F04 0/60psi 10 1 04K 04B 04F05 0/100psi 10 1 05K 05B 05F06 0/160psi 20 2 06K 06B 06F07 0/200psi 20 2 07K 07B 07F08 0/300psi 50 5 08K 08B 08F09 0/400psi 50 5 09K 09B 09F10 0/600psi 50 10 10K 10B 10F11 0/1000psi 100 10 11K 11B 11F

To Order

Model Range

P4598L - 05KP4598L - 11BP4598L - 008F

Page 3: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 3

CODE RANGE RANGE 401 -30"hg/0 -100/0kPa 405 -30"hg/0/15psi -100/0/100kPa 406 -30"hg/0/30psi -100/0/200kPa 407 -30"hg/0/60psi -100/0/400kPa 408 -30"hg/0/100psi -100/0/700kPa 409 -30"hg/0/150psi -100/0/1000kPa 410 -30"hg/0/160psi -100/0/1100kPa 411 -30"hg/0/200psi -100/0/1400kPa 412 -30"hg/0/300psi -100/0/2100kPa 417 0/15psi 0/100kPa 420 0/30psi 0/200kPa 422 0/60psi 0/400kPa 423 0/100psi 0/700kPa 425 0/160psi 0/1100kPa 426 0/200psi 0/1400kPa 427 0/300psi 0/2100kPa 428 0/400psi 0/2800kPa 429 0/500psi 0/3500kPa 430 0/600psi 0/4200kPa 431 0/800psi 0/5500kPa 432 0/1000psi 0/7000kPa 433 0/1500psi 0/10000kPa 435 0/2000psi 0/14000kPa 436 0/3000psi 0/21000kPa 437 0/4000psi 0/28000kPa 438 0/5000psi 0/35000kPa 439 0/6000psi 0/42000kPa 441 0/10000psi 0/70000kPa 442 0/15000psi 0/100000kPa

3

BADOTHERM Repairable (BDT) GaugesBDT183 (SS) Series• GlycerinfilledorDry(onrequest)• Stainlesssteelcaseandbayonet• Acryliclens(securityglasslensavailable)

Model BDT183A63 BDT183A100 BDT183A150

Model BDT183D63 BDT183D100 BDT183D150 1/4"npt 1/4"npt-1/2"npt* 1/2"npt Bourdon SS SS SS

100 mm (4")diameter

accuracy±1%Grade1A

150 mm (6")diameter

accuracy±1%Grade1A

Bronze Valves CODE Pressure 1075 MF 600psiat350°F 1/4"nptM/Fbrass1050 FF 600psiat350°F 1/4"nptF/Fbrass

Pressure Piston Snubbers Type Short Orifice Code Pressure PXS023B 5000psi 1/2"nptM/FbrassPXS023SS 15000psi 1/2"nptM/F316SSPXS022B 5000psi 1/4"nptM/FbrassPXS022SS 15000psi 1/4"nptM/F316SS

Adjustable Snubbers CODE Maximum Pressure MSB4 3000 1/4"nptM/Fbrass MSB2 3000 1/2"nptM/Fbrass MSS4 5000 1/4"nptM/FSS MSS2 10000 1/2"nptM/FSS

Pressure Piston Snubbers Type Long Orificefor smoother snubbing CODE Pressure PXS-010B 0-3000psi 1/4"nptM/FbrassPXS-010SS0-5000psi 1/4"nptM/F316SSPXS-060B 0-5000psi 1/4"nptM/FbrassPXS-060SS0-5000psi 1/4"nptM/F316SS

SiphonsCODE Capacity A03I 500psi&400°F 1/4"nptM/Msteel1300-25-B 250psi&400°F 1/4"nptM/Mbrass1300-25-3161000psi&650°F 1/4"nptM/Msteel1300-50-CS 600psi&750°F 1/4"nptM/Msteel1300-50-3161000psi&650°F 1/4"nptM/MsteelPXS21SS 500psi&400°F 1/4"nptM/Msteelschedule40PXS51SX 500psi&400°F 1/2"nptM/Msteelschedule80PXS214S 500psi&400°F 1/4"nptM/Msteelschedule40PXS514X 500psi&400°F 1/2"nptM/Msteelschedule80PXS516X 3000psi&100°F 1/2"nptM/Msteelschedule80

63 mm (2½")diameter

accuracy±1.6%GradeA

P R E S S U R E

Accessories for all type of gauges

Otherrangesavailableonrequest(ornotlisted)*Toorder1/2"npt,simplyreplace"4"bya"2"intheordercode.

Replacementofstandardglassbyaspecialglasswithareadingpointertoindicateminimumormaximumpressurereached.

Shippedwithazeroingkey,accordingtomodel.

Note:Accuracyofgaugemaygoupto±5%FS Code Description P01406310 Maximumpointerfor63mm P01406311 Maximumpointerfor100mm P0140631Z Maximumpointerfor150mm

Sintered Pressure SnubbersCODE Pressure BW41 1000psi 1/4"nptM/F,brass airandgasBW42 1000psi 1/4"nptM/F,brass water,lightoilsSW41 5000psi 1/4"nptM/F,SS airandgasSW42 5000psi 1/4"nptM/F,SS water,lightoilsSW43 5000psi 1/4"nptM/F,SS heavyoils

Dial psi/bar available for

4" and 6" diameter gauges

BDT183A100-244 0/20000psi/BaravailableAlso available

-244 Bar 0/20000 psi/Bar for 4" dia gauge.

CRN NUMBER0F04180.6

Page 4: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n44

P R E S S U R EENFM Pressure GaugesSeries 6211• 100mm(4“)diaSScase,brassfitting¼“npt• ±1.6FSGradeAaccuracy• Liquidfilled,acryliclens• SSsealedbezel

6211,lm 6214,cbm

CODE RANGE 6211-100-401 -30"hg/0/kPa6211-100-405 -30"hg/0/15psi/kPa6211-100-406 -30"hg/0/30psi/kPa6211-100-407 -30"hg/0/60psi/kPa6211-100-408 -30"hg/0/100psi/kPa6211-100-409 -30"hg/0/150psi/kPa6211-100-411 -30"hg/0/200psi/kPa6211-100-412 -30"hg/0/300psi/kPa6211-100-417 0/15psi/kPa6211-100-420 0/30psi/kPa6211-100-422 0/60psi/kPa6211-100-423 0/100psi/kPa6211-100-425 0/160psi/kPa6211-100-426 0/200psi/kPa6211-100-427 0/300psi/kPa6211-100-428 0/400psi/kPa6211-100-429 0/500psi/kPa6211-100-430 0/600psi/kPa6211-100-432 0/1000psi/kPa6211-100-433 0/1500psi/kPa6211-100-435 0/2000psi/kPa6211-100-436 0/3000psi/kPa6211-100-438 0/5000psi/kPa6211-100-439 0/6000psi/kPa6211-100-441 0/10000psi/kPa6211-100-442 0/15000psi/kPa

WEKSLER Process GaugesAA442 Series• Polypropyleneconicalsafetycasewith4.5”

(115mm)dial.• 316SSBourdontubeandfitting,

¼or½npt• Accuracy±0.5%FSGrade2AModelAA442dry,glasslensModelAS442drybutcanbefilledModelAY442liquidfilled,acryliclens

CODE* RANGE AS442-L2-4LW -30"hg/0/kPaAS442-L3-4LW -30"hg/0/15psi/kPaAS442-L4-4LW -30"hg/0/30psi/kPaAS442-L5-4LW -30"hg/0/60psi/kPaAS442-L6-4LW -30"hg/0/100psi/kPaAS442-L7-4LW -30"hg/0/150psi/kPaAS442-L9-4LW -30"HG/0/200psi/kPaAS442-LA-4LW 0/15psi/kPaAS442-LB-4LW 0/30psi/kPaAS442-LC-4LW 0/60psi/kPaAS442-LD-4LW 0/100psi/kPaAS442-LE-4LW 0/160psi/kPaAS442-LF-4LW 0/200psi/kPaAS442-LG-4LW 0/300psi/kPaAS442-LH-4LW 0/400psi/kPaAS442-LI-4LW 0/600psi/kPaAS442-LJ-4LW 0/800psi/kPaAS442-LK-4LW 0/1000psi/kPaAS442-LL-4LW 0/1500psi/kPaAS442-LM-4LW 0/2000psi/kPaAS442-LN-4LW 0/3000psi/kPaAS442-LO-4LW 0/5000psi/kPaAS442-LP-4LW 0/10000psi/kPaAS442-PZ-4LW 0/15000psiAS442-P2-4LW 0/20000psi*Standardmodel,¼"npt,lowermount

Dickson Pressure RecordersPW8 Series• 8inches(203mm)chartsize• Batterysupply• CaseNEMA4,IP66SpecificationsAccuracy: ±2%offullscaleOperatingtemperature -22to+122°F;-30to+50°CResponsetime 1to5secondsChartsize 8inches(20,3cm)diameterMountingoptions Stemorslotswithsmallincision,wallmountFitting 1/4"NPTthread,5/8"HexEnclosure PlasticNEMA4Xcasewithwindowlensondoor, IP66rDimensions 3.6x10.3x9.5in9.1x26.2x24.1cmIncludedAccessories AAbattery,redpenand60charts

Common accessories for PW8 and PW4Description Code

Pressurefittingaccessorieskit A791Firehydrantadapter(3")kit A793Filterkit(IncludesSnubber) R022Pens:6(red) P222Charts:boxof60(additional)

Pressure Order Order Chart Chart 24 hrs 7 days 24 hrs 7 days 0to100psi PW861 PW860 C410 C4120to300psi PW867 PW866 C422 C4310to1000psi PW875 C441 200psi PW865 PW864 C456 C436100psi PW470 PW470 C010 C012200psi PW474 PW474 C026 C040300psi PW476 PW476 C022 C036500psi PW479 PW479 C028 C056

PW4 Series• Compact4inch(101mm)chart• NEMA4Ximpermeableinterior• Batterysupply• Waterresistant• 7-Dayor24-HourrecordingSpecificationsAccuracy: ±2%offullscaleWorkingtemperature -22to+122°F,-30to+50°CResponsetime 1secondMountingoptions StemorslotswithincisionforwallmountFitting 1/4"NPTThread,5/8"HexCasing VeloxNEMA4XDimensions 6.25x6x2.9in,15.9x15.2x7.4cmIncludedaccessories AAbatteryandpen

6211

6214

LW Standard

RW Available

Othermodels

availableonrequest

Note.- PleasekeepinmindthatthePW4/8PressureChartRecordersarenotsuitableformonitoringammonia,acidsorothercorrosivesubstances.Pressure Recorders

`OTHER Models6212 Backflange6217U U-Clamp6216 Frontflange

Page 5: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 55

P R E S S U R E

Popular Range Codes(otherrangesonrequest)

Range Code Range .010CEP 10"CE 2.5kPa015CEP 15"CE 4.0kPa030CEP 30"CE 7.5kPa060CEP 60"CE 15kPa100CEP 100"CE 25kPa200CEP 200"CE 50kPa003PSI 3psi 20kPa005PSI 5psi 35kPa010PSI 10psi 70kPa010CEV -10"CE/Vac -2.5kPa/Vac015CEV -15"CE/Vac -4.0kPa/Vac030CEV -30"CE/Vac -7.5kPa/Vac060CEV -60"CE/Vac -15kPa/Vac100CEV -100"CE/Vac -25kPa/Vac200CEV -200"CE/Vac -50kPa/Vac

To orderModel + Range Code

BDT9A63-005PSI (63 or 100 mm)

ENFM Welded Diaphragm SealsEconomical 05 Series

• All316SS• (05-10)forrangesof-25”Hg/vacto300psi,

(05-15)for100to2000psi,(HP)for1000to5000psi;-20to200°C

• Size50x45mm(2”x113/16”)• For2.5”,4”and4.5”dialsizeCode Gauge Side Process Side05-100 ¼npt ¼npt05-101 ¼npt ½npt05-102 ½npt ½npt05-150 ¼npt ¼npt05-151 ¼npt ½npt05-152 ½npt ½nptHP-100 ¼npt ¼npt

HYETT Welded Diaphragm Seals15AW and 25AW Series• All316SS• (15AW)forrangesof0/100to0/2000psigat100°F

or(25AW)forranges-25”Hg/vacto0/1000psiat100°F

• Availablewith¼"nptpurgeport(25AWF)

Code Gauge Side Process Side15AW-4I4I ¼"npt ¼"npt15AW-4I2I ¼"npt ½"npt25AW-4I4I ¼"npt ¼"npt25AW-4I2I ¼"npt ½"npt25AWF-4I1I ¼"npt 1"npt SS-4-P SS316¼"nptplug

See 42Mand42M01seriesfor4”,4.5”and6”dialgauges

BDT9-8 Badotherm

15AW upto 3½ in

25AW upto 4½ in

GAUGES ONLY

PERMA-CAL Direct Drive Test GaugesTEST Series (101T)• 4.5”dial,±0.25%FSaccuracyGrade3A• BlackTurretcase(backflange)withsafetywall•Adjustablepointer• X-750InconelHelicalwoundtube• OnlyonemovingpartNogears,linkages,orspringstowearorbreak• 316SSfitting,¼or½,lowerorbackmount• Patentedmovement,moreprecise,doesnotneedglycerin• ComeswithaNISTcalibrationcertificate Code Range 101TTM25A21 30"Hg/0Vac101TTM27A21 30"Hg/0/30psi101TTM24A21 30"Hg/0/60psi101TTM29A21 30"Hg/0/100psi101TTM28A21 30"Hg/0/150psi101TTM30A21 30"Hg/0/200psi101TTM31A21 30"Hg/0/300psi101TTM32A21 30"Hg/0/400psi101TTM33A21 30"Hg/0/500psi101TTM34A21 30"Hg/0/600psi101TTMBAA21 0/30psi0/200kPa101TTMBCA21 0/60psi0/400kPa101TTMBDA21 0/100psi0/700kPa101TTMBEA21 0/150psi0/1000kPa101TTMBFA21 0/200psi0/1400kPa101TTMBGA21 0/300psi0/2000kPa101TTMBIA21 0/500psi0/3500kPa101TTMBQA21 0/600psi0/4000kPa101TTMBKA21 0/1000psi0/7000kPa101TTMBMA21 0/1500psi0/10000kPa101TTMBNA21 0/2000psi0/14000kPa101TTMBPA21 0/3000psi0/20000kPa101TTMBRA21 0/5000psi0/35000kPa101TTMBTA21 0/10000psi0/70000kPaStandard¼"npt,Lowermount

Other modelsModel 121TIS Accuracy±0.5%MS±1%FS 0-60psito3000psi,withoutcertificateModel 111TIS Accuracy±0.5%FS 0-60psito3000psi,withoutcertificate

On Request : Color/Cases:blue,green,red,white,yellow,steel,metalandSS Dials:2.5”,3.5”,6”and8.5”diameter Backmountor½”npt Case:frontflange,flangeless,backflange Accuracy:±0.5%or1.0%

BASCO Low Pressure GaugesBP9 Series• Blackpaintedsteelcase(alsoavaibleinfullSS

forBadotherm, BDT9-08Model)• Brassdiaphragm• Pressfitplexiglaslens• Standardrangesinmbarorequivalent: 0/25to0/600mbar,0/10to0/240"WC• Fitting¼”npt• Accuracy±1.6%FSat20°C

Model Description BBP9A63 63mm(2½")lowermount(lm)fittingBBP9D63 63mm(2½")centerbackmount(cbm)fittingBBP9E63 CBMwithfrontflange(flushmounting)

Basco

Accessories

WEKSLER Digital GaugesType WDG4251L• Accuracy±0.5%FS• Resolution5digits• Dialsize2½”x¼”bottommount,polycarbonatecase,316SSfitting• ON/OFFbuttonwithvariableautoshut-off,peakhold• Choiceofunits:psi,in.Hg,cmHg,kPa,MPa,bar,kg/cm2,ftH2O• Battery2AA,2000hours• Backlight(OFFbydefault),3,9or12hoursconnector,

rubberboot(XBI),custommadekeyboard• Workingtemperature:-10to+60°C

Code Plage W-DG4251LVC4L-XBI 30”/0/vac.W-DG4251LPC4L-XBI 0-15psiW-DG4251LPD4L-XBI 0-30psiW-DG4251LPE4L-XBI 0-60psiW-DG4251LPF4L-XBI 0-100psiW-DG4251LP14L-XBI 0-150psiW-DG4251LPH4L-XBI 0-200psiW-DG4251LPJ4L-XBI 0-300psiW-DG4251LPL4L-XBI 0-500psiW-DG4251LPP4L-XBI 0-1000psiW-DG4251LPS4L-XBI 0-2000psiW-DG4251LPT4L-XBI 0-3000psiW-DG4251LPV4L-XBI 0-5000psiW-DG4251LPY4L-XBI 0-10,000psiW-DG4251LPZ4L-XBI 0-15,000psiW-DG4251LP24L-XBI 0-20,000psi

Also available all stainless steel

Page 6: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n66

D I G I T A L P R E S S U R E

NOSHOK Pressure Transducers100 Series• Output4-20mA• Supply12to30Vdc• Accuracy±0.5%FS(±0.25%FSoptional• SSfitting¼"nptmale• Mini-Hirschmannfittingwithconnector

To order : 100 + range + 1127

Ranges (choose one) 30"Hg/0to30"Hg/0/300psig 0-5to0-7500psig 0-10000and0-15000psig 0-15to0-300psia

Otheroutputsandfittingsavailable

200 Series• Output0-5Vdcro0-10Vdc• Supply14to30Vdc• Accuracy±0.5%FS(±0.25%FSoptional)• SSfitting¼"nptmale• Mini-HirschmannfittingwithconnectorTo order : 200+range+1227for0-5Vdcor 200+range+1527for0-10Vdc

Ranges (choose one) 30"Hg/0to30"Hg/0to300psig 0-5to0-7500psig 0-10000and0-15000psig 0-15to0-300psiaOtheroutputsandfittingsavailable

DWYER Digital GaugesDPG-100 Series• Resolutionof4digits,0,425"high• Accuracyof±0.25%FS±1digit• Supply:twobatteriesAAA• ButtonON/OFF,back-light,2-minuteauto

shut-off(reversible)• Choiceofunits,autozero,minimum/maximum• Multipledisplayunits(availableaccordingtochosenrange):

psi,kg/cm²,bar,inHg,ftWC,kPa,oz/si,inchesH2O,mmHg,mbar,cmWC Code Range DPG-100 -14,7to0psig DPG-102 0to15psig DPG-103 0to30psig DPG-104 0to50psig DPG-105 0to100psig DPG-106 0to200psig DPG-107 0to300psig DPG-108 0to500psig DPG-109 0to1000psig DPG-110 0to3000psig DPG-111 0to5000psig5combinedmodelsavailable30"Hg-0-15to30"Hg-0-100psiDPG-000 Series• Resolutionof4digits,0.425"high• Accuracyof±0.5%FS±1digit• Supply:towbatteriesAAA• ButtonON/OFF,back-light,2-minuteautoshut-off(reversible)• Choiceofunits,autozero,minimum/maximum• Multipledisplayunitsavailable(accordingtochosenrange):

psi,kg/cm²,bar,inHg,ftWC,kPa,oz/si,inchesH2O,mmHg,mbar,cmWC Code Range DPG-000-14,7to0psigDPG-002 0to15psigDPG-003 0to30psigDPG-004 0to50psigDPG-005 0to100psigDPG-006 0to200psigDPG-007 0to300psigDPG-008 0to500psigDPG-009 0to1000psigDPG-010 0to3000psigDPG-011 0to5000psigDPG-015 0to8000psigDPG-020 30"Hg-0-15psigAccessories A-183 Rubberboot A-184 Carryingcase

BETA Digital GaugeModel BetaGauge P.I.• Large5½digitsdisplay,0.65"high,back-lit• Highaccuracyof:±0.05%FS,

withcompensatedtemperatureof0to50°C,

• calibrationcertificateINCLUDED• SScaseNEMA4/IP65,4.375"dia.• Batterysuppliedoroptional24Vdcinput)• SSlowermount¼"nptfitting,or

backmountinoption• Minimum,Maximum,TAREandTemperaturedisplay• Intrinsicallysafe(CSA),RS232output• Simulationkit,includinggauge,handpomp,fittingsandcase

• Choiceofdisplayunits(accordingtopressure):psi,bar,kg/cm²,inH2O,ftH2O,cmH2O,mH2O,kPa,mBar,inHg,mmHgandTorr.

Code Range PI-001 30,000"WC•70,000mbar PI-015C -15/0/+15psi•-1/0/+1bar PI-030C -15/0/+30psi•-1/0/+2bar PI-015 15,000psi•1bar PI-030 30,000psi•2bar PI-100 100,00psi•7bar PI-300 300,00psi•20bar PI-500 500,00psi•34bar PI-01K 1000,00psi•70bar PI-02K 2000,00psi•140bar PI-03K 3000,00psi•200bar PI-05K 5000,00psi•300bar PI-10K 10000,00psi•700bar

Accessories / Options -B Backmountfitting KIT Withpomp,hose,rubberboot andcase,upto500psi KIT Pump,hose,rubberboot andcase,upto10000psi 24 Externalsupply24Vdc1919151-001 Frontring80272 -B24 Backfittingand24Vdc

• 3"(76mm)diameter• SteelcaseNEMA4/4X• SS¼"nptfitting

• 3"(76mm)diameter• SteelcaseNEMA4/4X• SS¼"nptfitting

BETA High Accuracy Digital GaugeModel PiR• Accuracyof±0.04%ofmeasuredvalue+0.01%ofFS,

temperaturecompensatedfrom0to50°C• Large5½digitsdisplay,0.65"high,withback-light• CalibrationcertificateINCLUDED• SScaseNEMA4/IP65,4.375"dia.• Supply:batteriesor24Vdc(optional))• SSfrontmount¼"nptfitting,orbackmount(optional)• Minimum,Maximum,TAREandtemperaturedisplay• Intrinsicallysafe(CSA),RS232output• Kitforsimulationincludinggauge,handpump,

fittingsandcase• Choiceofdisplayunits(accordingtopressure):psi,bar,kg/cm²,

inH2O,ftH2O,cmH2O,mH2O,kPa,mBar,inHg,mmHgandTorr. Code Range PiR-030 0/30,000•2Bar PiR-030C -15/0/+30psi•-1/0/2Bar PiR-100 0/100,00psi•7Bar PiR-500 0/500,00psi•34Bar PiR-01K 0/1000,0psi•70Bar PiR03K 0/3000,0psi•200Bar

Rubberboot nowincluded!

Page 7: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 7

Explosion-Proof Pressure TransmitterMercoid Series 3200GFeatures• Completelyconfigurableusingzero/spanbuttons

(Nocalibratorrequired)• Rangeability(100:1)• Highaccuracy(±0.075%)• Automaticsensortemperaturecompensation• Fail-modeprocessfunction

Power Requirements: 11.9to45VDCOutput Signal: 4to20mA/HART*CommunicationElectrical Connection: Two1/2inchfemaleNPTconduit,screwterminal.Enclosure Rating: NEMA4X(IP66)andexplosionproofforClassI,DivI GroupsA,B,CandD.

D I G I T A L P R E S S U R EExplosion-proof Differential Pressure TransmitterMercoid Series 3100DFeatures• Completelyconfigurableusingzero/spanbuttons

(Nocalibratorrequired)• Rangeability(100:1)• Highaccuracy(±0.075%)• Automaticsensortemperaturecompensation• Fail-modeprocessfunction• Selectableengineeringunits

Power Requirements: 11.9to45VDCOutput Signal: 4to20mA/HART*CommunicationElectrical Connection: Two1/2inchfemaleNPTconduit, screwterminal.Enclosure Rating: NEMA4X(IP66)andexplosionproof forClassI,DivIGroupsA,B,CandD.

Model Range Max. Pressure psi (kPa) psi (bar) 3200G-1-FM-1-1 -14.5to21(-100to150) 58(4)3200G-2-FM-1-1 -14.5 to 217 (-100 to 1500) 580 (40) 3200G-3-FM-1-1 0to725(0to5000) 2000(138) 3200G-4-FM-1-1 0 to 3600 (0 to 25000) 10000 (690)

Model Calibrated Span (Min. to Max.) Lower Range Limit Upper Range Limit 3100MP-2-FM-1-1 0.6 to 30 in w.c. 0.15 to 7.5 kPa -30 in w.c. -7.5 kPa 30 in w.c. 7.5 kPa 3100MP-3-FM-1-1 1.5 to 150 in w.c. 0.373 to 37.3 kPa -150 in w.c. -37.3 kPa 150 in w.c. 37.3 kPa 3100MP-4-FM-1-1 7.5 to 750 in w.c. 1.865 to 186.5 kPa -750 in w.c. -186.5 kPa 750 in w.c. 186.5 kPa 3100MP-5-FM-1-1 1 to 100 psi 6.9 to 690 kPa -100 psi -690 kPa 100 psi 690 kPa 3100MP-6-FM-1-1 3 to 300 psi 20.68 to 2068 kPa -300 psi -2068 kPa 300 psi 2068 kPa

FLOTECT® Flow Mini-Size SwitchModels V10 & V11 (DWYER)• Forpipes½"to2"(adjustablevalve)• Airtightorwaterproofcase(V11).Approved:

UL,CE,CSA(V10)andUL(V11),½"npt• Max93°C-200°F(V10)and121°C–250°F(V11)• Max1000psig(brass)or2000psig(SS303)• SPSTswitch1.5Ato24Vcc Code Description V10 Brass,adjustableNOorNF V10SS SS303,adjustableNOorNF

DWYER Economical Level SwitchesSeries F7• Contactshermeticallysealed,compactandreliable

Vertical Installation - Standard Models Model Float/Rod Max Temp. Max Pressure Min.S.G. Électrical Mount F7-SB Buna-N&époxy 220°F/105°C 150psig 0,60 25VA;1Ato220Vca 18”wiresNo22,1/8”npt inox316 F7-SS2 Inox316 300°F/149°C 450psig 0,75 25VA;1Ato200Vca 18”wiresNo22,1/8”npt F7-BT Buna-N&époxy 220°F/105°C 150psig 0,45 30VA;0.14Ato220Vca 24”wiresNo22,1/8”npt PBT

Montage horizontalF6-HPS-11 Polypropylene 176°F/80°C 116psig 0,60 20VA;0.08Ato240Vca 11,8”wiresNo20,threadsM16x2F6-HPS-21 Polypropylene 176°F/80°C 116psig 0,60 20VA;0.08Ato240Vca 11,8”wiresNo20,½”npt(ext) F6-MHS SS304 257°F/125°C 218psig 0,85 20VA;0.08Ato240Vca 11,8”wiresNo22, ½” M16x2 F7-HSS SS316 392°F/200°C 300psig 0,60 30VA;0.14Ato220Vca 24”wiresNo22,½”npt(ext/int)

FLOTECT® Level SwitchSeries L4 (DWYER)• Magneticswitch,SPDT5Ato125/250Vca• Leakproofcase,explosionproof• ApprovedUL,CSA,FM,CE,ATEX(optional)• Max4/275°F(-20/135°C)oroptionMT

upto400°F(205°C);1000psig(brass)or2000psig(SS316),standardfloat100psig(0.7specificgravity)

• Fitting1-1/2”nptmale• Options:DPDT,goldcontacts,high

temperature,actiondelay,ATEX,SAA,verticalinstallation,floats,etc.

Code Description L4 Brass,horizontalinstallationL4SS SS,horizontalinstallation

FLOTECT® Level SwitchModel L8 (DWYER)• Economical,leakproofcase,resistant

tochemicalproducts• ApprovedCE,UL508• Max212°F–100°C,150psig• Fitting½”nptmale(electricalconduit))

and1”nptmale(process)• SwitchSPDT5Ato125/250Vac• FloatPPS,specificgravity,0.6min.,

SS316orInconelpinandspring,ceramicmagnet8

• Options:Gold(L8-MV),inconelalloy(L8-INC)contacts,airtightcase(L8-WP)

Code Description L8 Interrupteuràmontagehorizontal

F7-SB

F7-HPS-11

L4 L8V10

For display, add -LCD to model code

For display, add -LCD to model code

Page 8: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n8

D I F F E R E N T I A L P R E S S U R EDWYER Differential GaugesMagnehelic® 2000 Series• Aluminumcase,4¾"dia.• Accuracyof±2%FS(±3%forthe-0and±4%forthe-00)• Female1/8"nptfitting(twopairs)• Shippedwith21/8"nptcap/s,21/8"threadedadapters

andscrewforonsurfaceassembly Code Inches H2O Pascals 2000-00D 0-0,25 0-602000-0D 0-0,5 0-1252001D 0-1 0-2502002D 0-2 0-5002003D 0-3 0-7502004D 0-4 0-1,0kPa2006D 0-6 0-1,52008D 0-8 0-2,02010D 0-10 0-2,52015D 0-15 0-3,752020D 0-20 0-52025D 0-25 0-6,252030D 0-30 0-7,52040D 0-40 0-102050D 0-50 0-12,52060D 0-60 0-15Popular AccessoriesA-301 StaticpressureprobewithcompressionfittingA-302 Staticpressureprobe,barbedfittingA-432 CarryingcaseandsupportplateA-605 Kitforfilters(plate,2probes, 2aluminiumhosesand2valves)

DWYER Differential Pressure SwitchPhotohelic® A3000 Series• Accuracyof±2%FA(±3%forthe-0and±4%forthe-00)• TworelayoutputsDPDT10Ato120Vac,6Ato240Vac• Easysetpointadjustmentinfront,fixeddeadbandoflessthan1%FS• Femalefitting1/8"npt• ApprovedUL/AcnorPopular Models Code inWC A3000-00 0-0,25A3000-0 0-0,5A3001 0-1A3002 0-2A3003 0-3A3004 0-4A3006 0-6A3008 0-8A3010 0-10A3015 0-15A3020 0-20A3025 0-25A3030 0-30A3040 0-40A3050 0-50A3060 0-60A3080 0-80A3100 0-100A3150 0-150

Popularranges.Othersavailableonrequest

Upto500inH2O,300inH2O,30psi,6000psi

Plagespopulaires;beaucoupd'autres

disponiblessurdemande.

Jusqu'à150poH2O,100mmH2O,300cmH2O,30kPa

Popular AccessoriesCode Description A-301 Staticpressure probe,compression fitting A-302 StaticPressure Probewithbarbed fitting

DWYER Inclined Column ManometerModel 25 - Mark II• Accuracyof±3%FS• Rangefrom-0.5to0.3inchesH2OCode Description 25 Shippedwith8feetofflexiblehose; 2fittings1/8"npt, 1bottleofredoil0.826

DWYER Vertical Column Gauges1211 Series• FlexibleU-Tube• Shippedwith:smallmetalcarryingbox,magneticattachments,

nylonvalves,1bottle(¾oz)ofgreenfluorescentconcentrate(WM)orredoil0.826(D)

• Mayalsobefilledwithmercury(inHg),soldseparately Model inH2O 1211-8WM 4-0-41211-12WM 6-0-61211-16WM 8-0-81211-24WM 12-0-121211-30WM 15-0-151211-36WM 18-0-181211-48WM 24-0-241211-60WM 30-0-301211-72WM 36-0-361211-120WM 60-0-60

DWYER Inclined Column ManometerModel 400-10• Measurementofvelocityand

pressuredifferentialwithPitottube

• Maximumstaticpressureof100psi• From0to10inchesH2Oand400to12500ft/min• Resolutionof0.01inchH2Oininclinedmode

and0.10inchH2Oinverticalmode• Othermodelsavailable:

0to5and0to23inchesH2O,0to250mmH2OCode Description 400-10_KIT Manometershippedcompletewith18"Pitottube, 2rubberhoses,brasstube,magnet,redoil calculatingrule,steelcaseand manualinFrench

DWYER Differential Pressure SwitchSeries 1900

• Ajustingscrewtosetpoint• Fittings1/8"npt• Relay15Ato120/480Vac• Aluminumcase,1lb,verticalinstallation

forairorcompatiblegas

Code Description Dead Band min.1910-00 0.07à0.15poucesH2O 0.041910-0 0.15à0.55poucesH2O 0.101910-1 0.40à1.75poucesH2O 0.151910-5 1.40à5.5poucesH2O 0.301910-10 3.00à11.75poucesH2O 0.401910-20 4.20à20.0poucesH2O 0.40

DWYER Differential Pressure SensorsMS, Magnesense® Series• Case3-7/16"dia.,NEMA4X(IP66)• AccuracyMS-X21:0.5"and0.25"±1%,0.1"±2%

(validforbidirectionalmodels),100et50Pa±1%,250Pa±2%(instandardconditions)

• Functionalpressure,max1psi;burstingpressure,10psi• Output4-20mAor0-10V• Adjustableresponsetime,0.5to15sec• Adjustmentofzeroandscopebypush-button• OptionaldigitaldisplayLCD• Fittingtube,3/16"(5mm)• Supply,10to35Vdc(2wires),17to36Vdcor21.6to33Vda(3wires) Code Output Ranges MS-021 4-20mA ±0.1inH2O,±0.2inH2O,±0.5inH2O (±25,±50,±100Pa) MS-111* 4-20mA 1poH2O,2poH2O,5poH2O (250,500,1250Pa) MS-121* 4-20mA 0,1inH2O,0,25inH2O,0,5inH2O (25,50,100Pa) MS-131 4-20mA 10poH2O(2kPa) MS-141 4-20mA 15poH2O(3kPa) MS-151 4-20mA 25poH2O(5kPa) -LCD ForLCDdisplayinstalledatfactory (addtocode-LCDwhenordering). * Modelsavailablewithstaticpressureprobemounted atthebackofsensor;simplychangethelastdigitfrom1to2. (Ex.:MS-122) A-435 ForLCDdigitaldisplayinstalledbyuser. Availableonallmodels. Fora0-10Voutput,simplychangethefirstdigit from1to3(Ex.:MS-311)

Page 9: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 9

D I F F E R E N T I A L P R E S S U R EKIMO Differential Pressure Sensors / TransmittersSensor / Transmitter Class 110 – CP111 - CP112 - CP113•Output: 0-10Vor4-20mA,Activesupply24Vac/Vdc(3-4wires) 4-20mA,loopPassivesupply16to30Vdc(2wires)•CaseABSVOIP65,withorwithoutdisplay•Measuringunits: Pa,mmH2O,inWG,mmHG,daPa,kPa,hPa,mbar•Accuracy CP111±1%ofreading±2Pa CP112±1.5%ofreading±3Pa CP113±1.5%orreading±3mmH2O•Auto-zero: Manualbypush-button Automaticbysolenoidvalve(CP111)

Code Description Display CP111-AO Active0-10Vou4-20mA,24Vac/Vdc YesCP111-AN +/-100Pawithsolenoidvalve No

Sensor/Transmitter Class CP114 - CP115• Output: 0-10Vor4-20mA,Activesupply:24Vac/Vdc(3-4wires) 4-20mA,loopPassivesupply:16à30Vdc(2wires)• CaseABSVOIP65,withorwithoutdisplay• Measuringunits: mBar,inWG,mmHG,PSI,mmH2O,daPa,hPa,kPa• Accuracy:1.5%ofreading3mBar• Auto-zero :Manualbypush-button

Code Supply / Output DisplayCP11 AO Active–0-10Vor4-20mA,24Vca/cc YesCP11 AN Active–0-10Vor4-20mA,24Vca/cc NoCP11 PO Passive–4-20mA,16to30Vcc YesCP11 PN Passive–4-20mA,16to30Vcc No

Code Description LCC-S Configurationsoftwareformonostats andsensorsClass110/210 withnoticeandUSBcable

KIMO Differential Pressure and Temperature Sensors / TransmittersSensors / Transmitters Class 210 – CP210• Rangefrom-100/+100Pato-2000/+2000mBar (dependingonmodel)• InputPt100onterminalformeasuring

temperature:rangefrom-100to+400°C(probesoptional)

• Configurableintermediaryscales• Analogueoutput4wires0-5/10Vor0/4-20mA• Supply:24Vdc/Vacor115/230Vac• Tendencyindicator• CaseABSV0IP65,withorwithoutdisplay• Accuracy: CP211/212 ±0.5%ofreading±2Pa CP213 ±0.5%ofreading±10Pa CP214 ±0.5%ofreading±0,5mBar CP215 ±0.5%ofreading±2mBar Temperature Function available on CP211/212/213/214/215 ±0.3%ofreading±0.25°C Velocity and Flow Function available on CP211, CP212 et CP213

Range Supply Display CP21 1 BN ±100Pa (B) 24Vac/Vdc No CP21 1 BO ±100Pa (B) 24Vac/Vdc Yes CP21 1 HN ±100Pa (H) 115ou230Vac No CP21 1 HO ±100Pa (H) 115ou230Vac Yes

CP21 BN (B) 24Vac/Vdc No CP21 BO (B) 24Vac/Vdc Yes CP21 HN (H)115ou230Vac No CP21 HO (H)115ou230Vac Yes

Accessories Description TC5X8-25 Rollofcrystaltube5x8mm25mTC4X6-25 Rollofcrystaltube4x6mm25m,adapted forCP103,CP104orCP203,CP204TS4X7-25 Rollofsoftsiliconetuberoll4x7mm, whiteorblack,25m

KIMO Differential Pressure SwitchPST•Inverterforrelayoutput3A/230Vac,supply24Vac/Vdc•Visualandsoundalarm,redledonfront•CaseABSVOIP65•Auto-calibrationsolenoidvalve (onlywithPST11)•Measuringunits: PST11, PST12, PST13 Pa,mmH2O,inWG,mmHG, daPa,kPa,hPa,mBar PST14, PST15 mBar,inWG,mmHG,PSI,mmH2O, daPa,hPa,kPa,Bar•Accuracy: PST11 ±1%ofreading±2Pa PST12 ±1,5%ofreading±3Pa PST13 ±1.5%ofreading±3mmH2O PST14 et PST15 ±1.5%ofreading±3mBar

Order Code Ranges PST– 11 -100/+100Pa (withsolenoidvalve)

PST– 12 -1000/+1000Pa

PST– 13 -10000/+10000Pa

PST– 14 -500/+500mBar

PST– 15 -2000/+2000mBar

2-1000/+1000Pa3-10000/+10000Pa4-500/+500mBar5-2000/+2000mBar

CP116-AOCP116-AN

KIMO Sensor / Transmitter for atmospheric pressureCP116•Measuringspanfrom800to1100hPa•PressureindicationinmBar,mmHGorhPa•Output:0-10Vor4-20mA,Activesupply24Vac/Vdc(3-4wires) 4-20mA,loopPassivesupply16to30Vdc(2wires)•Measuringunits:mBar,hPa,mmHG•Accuracy:±3hPa•CaseABSVOIP65,withoutdisplay

Code Output Display Code

CP116 Active Yes Passive No

RANGE CODE

MEASUREMENT SCALE

RANGE CODE

MEASUREMENT SCALE

2 -1000/+1000Pa3 -10000/+10000Pa4 -500/+500mbar5 -2000/+2000mBar

Page 10: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n10

D I F F E R E N T I A L P R E S S U R E

KIMO Inclined Column ManometersSeries HP and TX• Highmeasurementsensitivity• Verylowpressureranges• Zeroadjustmentbymovingthesliderule• TXModel:centeredzeroscalewithpossibilityof

measuringbothpositiveandnegativepressures• Integratedspiritlevelforhorizontaladjustment• ShippedwithwhitePVCsupport,2screwsand2dowelpins,

2tubingadaptors487andabottleofAWS10oil

Model Range HP05-PO 0to0.20inH2OHP10-PO 0to0.40inH2OHP15-PO 0to0.60inH2O TX25-PO 0.1to0to0.1inH2OTX50-PO 0.2to0to0.2inH2OTX75-PO 0.3to0to0.3inH2O

KIMO Portable Liquid Column ManometersSeries MT and KM45• Easytocarry• Zeroadjustmentbymovingthesiderule• Shippedwithconnectingsleeves,onebottleofliquid,

acarryingcaseorpouch

Model RangeMT40-PO 0-1.6KM45-PO 0-18

AlsoavailableinmBar,mmH2OorPa

Also available in: mmH2O et Pa

KIMO Vertical Column ManometersTJ and LU Series• Zeroadjustmentbymovingthesliderule• ModelLU:withUshapedcolumntomeasure

consecutivelybothpositiveandnegativepressures• PortableusewithVOLT1Sliquid• ScalesininH2Oandequivalents,mmH2O,mbar,mmHg,inHg• ShippedwithwhitePVCsupport,2screwsand2dowelpins,

2adaptors487andabottleofAWS10oil Model Range in WC TJ100-PO 0-4TJ150-PO 0-6TJ300-PO 0-12TJ600-PO 0-24TJ1000-PO 0-40 LU100-PO 2-0-2LU200-PO 4-0-4LU400-PO 8-0-8FM-KS.10Setof2magneticfixturesAlso available: withoilVOLT1S0-18to0-86inH2Oormercury0-9to0-46inHg

KIMO Mesuring Blades DEBIMOAspartofKIMOsdifferentialpressurecontrolinstruments(sensors-transmitters,electronicmicromanometers,liquidcolumnmanometers),themeasuringbladesDÉBIMOallowaccurateindication,controlandrecordingofvelocityandflowvaluesinproperinstallations.Features• Capacityofvelocitymeasuresfrom590to20,000ft/min.

3to100m/s(9Pato10000Pa)• Airfoildesignlimitschargeloss(<3%)andturbulences• Distributionofmeasuringaperturespermitsmediumairflowcontrol

(averageofdifferentialpressures).• Materials:extrudedaluminium,galvanizedsteelfixingbracket,SSscrews• Operatingtemperature:100°C(maximum210°Condemand)• Accuracy:from3%to5%,dependingoninstallation.

*Itishighlyrecommendedtomakeanadjustmentontheactualspeedreadingwithananemometerafterinstallation.

• Availability:from100mmto3000mm(from4into118in).Code Longueur utile en mm Debimo100 Measuringblade100mmlongDebimo125 Measuringblade125mmlongDebimo160 Measuringblade160mmlongDebimo200 Measuringblade200mmlongDebimo250 Measuringblade250mmlongDebimo300 Measuringblade300mmlongDebimo315 Measuringblade315mmlongDebimo400 Measuringblade400mmlongDebimo500 Measuringblade500mmlongDebimo600 Measuringblade600mmlongDebimo630 Measuringblade630mmlongDebimo800 Measuringblade800mmlongDebimo1000 Measuringblade1000mmlongDebimo1500 Measuringblade1500mmlongDebimo2000 Measuringblade2000mmlongDebimo2500 Measuringblade2500mmlongDebimo3000 Measuringblade3000mmlong

Possibilityofimperialandspecialdimensions

Velocity / Flow Sensor Class C310• Usesmultifunctionsensorsinvelocityand

flowmodet• 2inputsforinterchangeableprobes• 1slotforinterchangeablecardSPI-2• Simultaneousdisplayof1to4parameters• Inclinationindicator• 4visual(bicolorled)andaudiblealarms• 2analogoutputs(4wires)0/5-10Vor0/4-20mA,

2additionaloutputs(option)• 4-relaycard(option)• Supply:24Vdc/Vacor115/230Vac• Outputsdiagnostic• Ethernetcommunication(option)• RS485communication,MODBUSprotocole(option)• ABScasewithSSIP65front,withorwithout

backlightgraphicscreen• Assembly:quarterturnonSSwallfixationplate

C310

Code Description C310–BO Multifunctionsensor,supply24Vca/cc,withdisplayC310–BN Multifunctionsensor,supply24Vca/cc,withoutdisplayC310–HO Multifunctionsensor,supply115/230Vca/cc,withdisplayC310–HN Multifunctionsensor,supply115/230Vca/cc,w/odisplayINTERCHANGEABLE PRESSURE BOARDS FOR C310 AND CA310InterchangeableboardwithsolenoidvalveandthermocoupleKconnectorforC310transmitters.Suppliedwithpressureconnectors,siliconetubeandadjustmentcertificate.

Code MEASURING RANGE SPI2-100 -100/+100PaSPI2-500 -500/+500PaSPI2-1000 -1000/+1000PaSPI2-10000 -10000/+10000PaOther available options: Code Description O2S 2additionaloutputs:current/voltageC4R 4-relay"3A"board,with3-pointterminalblockCETHE Ethernetnetworkboard,forconfigurationanddatatransmission. Suppliedwithcapandairtightsockconnectors-mounting shallbedoneatourfactorySQR/3 Squarerootextractionfordirectcalculationofairvelocityand airflow,fromthepressuremeasurement RS5 RS485ModbusforconfigurationanddatatransmissionHRP Highresolutionforpressureex:0.1Pa

Page 11: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 11

A T m o S P h E R I C P R E S S U R E

AIRFLOW Digital BarometersModel DB3• Range:from-1000to+2000mbar(-15to+29psi)• Accuracy:±0.5%ofreadingvalue• Memoryof750readings• Analogoutput:from-1to+1V

Code Description DB3 Digitalbarometerwith carryingcase,9Vbattery, softwareandcables71694302 Adapter110Vca

MAXIMUM Analog BarometersCode Description Predictor-A Chromedaluminiumbarometerof 4¾"dia,silverfaceplate(A) orblackfaceplate(B),inmercury inchesonlyProteus-A Chromedbrassmanometerof 6½"dia,silverfaceplate(A)or blackfaceplate(B),double scaleinmercuryinchesandkPa

LUFFT Digital BarometerAll-in-one XA1000 Portable Instrument•Integratedairpressuresensor800…1,100mbar•±0.5mbarat25°C•TFTtouchscreen•HOLD/MIN/MAX/AVG•Otherprobessoldseparately

(Humidity/Temperature,Flow,AirPressure) Code Description 5900.00 Integratedbarometricsensor,withUSBcableandsoftware

DWYER Pitot TubesSeries 160• MadeofSS304• Standardmodel:5/16"dia(Series160),max.1500°F(815°C)• Pocketmodel:1/8"dia(166and167),max.800°F(426°C)• StypemodelS(Series160S),max.1500°F• ShippedwithA-532calculatorCode Length 160-8 8"160-12 12"160-18 18"160-24 24"160-36 36"160-48 48"160-60 60"166-6 6",antenna3"166-12 12",antenna3"167-6 6",antenna1½"167-12 12",antenna1½"A-158 Cablegland(mountingflange)

KIMO Pitot TubesSeries TPL-T with Thermocouple• Ellipsoidaltip• TypeKthermocoupleprobeintegrated,

with1.5mconnectioncable• SSbody,max.600°C(1112°F),

andupto1000°C(1832°F)(optional)

Code Diameter LengthTPL-03-100-T 3mmx100mm 4inTPL-03-200-T 3mmx200mm 8inTPL-03-300-T 3mmx300mm 12inTPL-06-300-T 6mmx300mm 12inTPL-06-500-T 6mmx500mm 20inTPL-06-800-T 6mmx800mm 31inTPL-08-1000-T 8mmx1000mm 40inTPL-08-1250-T 8mmx1250mm 50inTPL-12-1500-T 12mmx1500mm 60inTPL-12-2000-T 12mmx2000mm 79inTPL-14-2500-T 14mmx2500mm 98inTPL-14-3000-T 14mmx3000mm 118inTIG Solder Foruseupto1000°C(except3mmdia)PE.458-3 Cablegland(mountingflange)for3mmdiaPE.458-6 Cablegland(mountingflange)for6mmdiaPE.458-8 Cablegland(mountingflange)for8mmdia

Length

Leng

th

Antenna

Minis

TSI Hydronic ManometersSeries HM

• Forbalancinghydronicsystemsandtestinghydronicpumpsefficiency

• Measuresofdifferentialpressure• Ruggedandsealedcase• Flowcalculationanduseof

Cv(Kv)factors• Memoryof100factors• Calculationofbrakingpower,

heatflowCv(Kv)factorsandpropellerCv(Kv)dimensions(ModelHM685only)

• Memoryof1000readingstransferabletoaPC(HM685only)

• Ranges:from0to300psi(0to2068kPa),0to9999USGPM(0to631l/s,0to2271m³/h),-40to121C/F(optimaltemperatureprobewiththeHM675)

• Resolution:from0.001psi(0.01kPa),0.0001USGPM(0,00001l/s)

• Accuracy:±1%VMor0.036psi(0.25kPa)from0to250psi

• Choiceofunits:psi,inH2O,ftH2O,kPa,mm.Hg,inHg,mH2O,bar,USGPM,UKGPM,m³/h,l/s,l/m,degreesF,degreesC

• Statistics:min,max,average,totalofmeasures(HM680only)• Pressurefittings:¼”flare37°male• Warranty:2years

Code Description HM675 Hydronicmanometer,rigidcase withstandardfittings,2hosesof 6.7feetx¼(2mx6mm)withvalves, 2Bell&Gossetprobes,2adaptersP/T andsupplycable HM685 Hydronicmanometer,solidcase withstandardfittings,2hosesof 6.7feetx¼(2mx6mm)withvalves, 2Bell&Gossetprobes,2adaptersP/T andsupplycable,temperatureprobe, softwareandUSBtransfercable632.650.005 Kitof36fittingsandaccessories

Pitot tubes in "S" also available

KIMO Digital BarometerModel MP55• Choiceofpressureunits:mbar,mmHg,hPa• Easytouse• HOLDfunction• Built-inprobe• Autozero:20minutes

Instrumentsaresuppliedwith:anadjustmentcertificate,softcaseand2x1mofsiliconetube.

SPECIFICATIONS Measuring Accuracy Résolutions Response Ranges Time MP55 From700to1100mBar ±2mBar 0.1mBar T63<10sec. 0.1mmHg 0.1hPa

Page 12: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n12

D I F F E R E N T I A L P R E S S U R E - P R E S S U R E C A L I B R A T o R S

KIMO Digital MicromanometersMP110 Series• Backlitdisplay• HOLDfunction• 2linedisplaywithmax/minreadings• ConfigurableAutoshut-off,0to20minutes• ManualAutozero

Instrumentsaresuppliedwithacalibrationcertificate,*Transportcase(ST110)StainlesssteeltiptubeØ6x100mm,andtwo1msilicontubingØ4x7mm

Code Range Accuracy Resolution Units MP110 ±1000Pa ±0.5%v.m. 1Pa Pa,mmH2OMP110S (4inH2O) ±2Pa inWg,daPa

MP111 ±1000mmH2O ±0.5%v.m From0to mmH2O,kPa,MP111S (40inH2O) ±2mmH2O ±200mmH2O inWG,mbar, 0.1mmH2O mmHg,daPa Beyond:1mmH2O

MP115 ±500mbar ±0.5%v.m.± 0.1mbar kPa,inWG,mbar,MP115S (200inH2O) 0.5mbar mmHg,PSI

MP112 ±2000mbar ±0.5%v.m 1mbar kPa,inWG,mbar,MP112S (800inH2O) ±2mbar mmHg,PSI,bar

*(exceptClassMP110S),

KIMO Digital MicromanometersSeries MP50 and MP51• HOLDfunction• Autoshut-off:20minutes• ManualAutozero

Instrumentsaresuppliedwithanadjustmentcertificate,asoftcaseandtwo1mofsiliconetube.

Code Range Accuracy Resolution Units MP50 ±1000Pa ±0.5v.m. 1Pa Pa,mmH2O, (4inH2O) ±2Pa inWg,daPa

MP51 ±1000mmH2O ±0.5v.m. From-200to mmH2O,kPa (40inH2O) ±2mmH2O +200mmH2O inWg,mbar, 0.1mmH2O mmHg,daPa Over:1mmH2O

Micro-manomètre avec mesure de la vitesse d'airModèle MP120

• Backlitdisplay• HOLDfunction• 2linedisplaywithmax/minreadings• ConfigurableAutoshut-off,0to20minutes• ManualAutozero

suppliedwithaCalibrationcertificate,(MP120)orAdjustingcertificatewithoutdata(MP120S)two1msilicontubingØ4x7mm,StainlesssteeltiptubeØ6x100mm,Transportcase(ref:ST110)

Code Range Accuracy Resolution Units MP120 ±1000Pa ±0.5%v.m.±2Pa 1Pa, Pa,mmH2O,MP120S (4inH2O) 2to5m/s:±0.7m/s 0.1m/s, inWg,daPa, 0to40m/s 5to40m/s 1fpm (400to7875fpm) ±0.5%ofreading ±0.3m/s

PressureTemperature

HumidityAir VelocityElectricity

Dimensional

Also available: on-site service

KIMO Thermo-anemo-manometerMP210• Measurementofpressure,airvelocityandairflow• Interchangeablemoduless• 2inputsforPt100temperature• Upto6measurementssimultaneously• Memorycapacityupto1000datasetof20000points• CanbeusedwithhotwireorvaneanemometerprobesPRESSURE• Automaticautozerowithsolenoidvalve(MP210P)• Manualautozero(MP210M,G,HandHP)• Pressureintegration(0to9)• Point/pointaverage,Automaticpoint/pointaverage,

AutomaticaverageAIR VELOCITY AND FLOW• LargechoiceofPitottubeorDebimobladesor

factorforothersensingelement• Selectionofsection• Selectionofunits• Manualorautomatictemperaturecompensation• Manualatmosphericpressurecompensation• Kfactor,K2factor

CODE Range Accuracy MP 210 P ±500Pa(±2inH2O) From-100to+100Pa:±0.2% ofreading±0.8Pa Beyond:±0.2%ofreading±1.5P

MP 210 M ±2500Pa(±10inH2O) ±0.2%ofreading±2PaMP 210 G ±10000Pa(±40inH2O) ±±0.2%ofreading±10Pa

MP 210 H ±500mBar(±200inH2O) ±0.2%ofreading±0,5mBar

MP 210 HP ±2000mBbar(±800inH2O) ±0.2%ofreading±2mBar

Options et accessoires M4TC 4T/CchannelsmoduleSCO-110 CO/temperatureprobeSFG 300 GasleakprobeSTA TachometercontactandnoncontactprobeSAD BackpackLPC-2014 Dataloggersoftware Pitottubes(seepage11) Hotwireprobe(seepage17,18,19) (alsoavailableintelescopicmodel) Vaneprobes(seepage17,18,19) Alsoavailableintelescopicmodelandinwirelessmodel Largechoiceoftemperatureprobes(seerelateddatasheet): ambient/contact/penetration/immersion...

The instruments are supplied in a transport case with a calibration certificate, a charger and a USB cable.

Calibration LaboratoryISO 17025

(In pressure and temperature)

Page 13: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 13

D I F F E R E N T I A L P R E S S U R E - P R E S S U R E C A L I B R A T o R S

ALNOR Digital MicromanometerModel EBT730ThenewAlnorEBT720isthemostadvanced,versatileanduserfriendlybalancinginstrumentofferedthesedays.Thebestprobesandaccessoriesavailablemaketheidealtoolforanybalancingtechnician.• Differentialrange:±15inH2O(3735Pa);resolutionof0.00001inH2O

andaccuracyof±2%VM±0.001inH2O• Absolutepressure:14to40inH2O(356to1016mmHg)• Velocity:25à8000ft/min(withPitottube)• 0to95%RH(probeinoption)and-40to121°C

(dependingontheprobe)• Memory:1000measures(downloadingsoftwareincluded),includingminimum,

maximumandaverage,continuousorintervalsampling(10to600seconds)• Warrantyof2years

ALNOR Digital MicromanometersAXD 620Differential or Static Pressure• Range:–15to+15inchesH2O

(-28.0to+28.0mmHg,-3735to+3735Pa)• Accuracy:±1%ofreading±0.005inchesH2O

(±1Pa,±0.01mmHg)Air Velocity

• Range:250to15,500ft/min(1.27to78.7m/s)

Air flow• Range:dependingontheairvelocity,pressure,

conductdimensionsandKfactorMemory (AXD620 only)

• Range:moretan12,700measuresin100setsoftests(ID)

To Order Code Description AXD610 Micromanometer,hardcarryingcase, batteries,NISTcertificateandusermanual AXD620 Micromanometer,hardcarryingcase, staticprobe,rubberhose,LogDat2software, USBcable,batteries,NISTcertificateandmanual

Code Description EBT730 Micromanometer,case,4rechargeablebatteriesAA, externalbatterycharger,CAadapter,Pitottube18", 2staticpressureprobes,16-feetNeoprenetubing, downloadingsoftwareCompudat™ NISTcertificateandmanualOptional Accessories and Probes 801090 16-pointsX-shapedsensor 800187 AirFlowvelocityprobe 8934 Thermalprinter 800220 Humidity/temperatureprobe

801090

EBT

8934

FLUKE Digital MicromanometerModel 922• Powerfulmeasuringinstrumentforstaticand

differentialpressure,velocityandairflow• Adjustableductsdimensionsfor maximumvelocityaccuracy• Ranges:from±16inH2O(±4000Pa)

(mmH2O,mbar,psi),250to16000ft/min(1to80m/s),0to99999ft³/minandm³/hr,l/s

• Accuracy:±1%+0.01inH2O;±2.5%VMto2000ft/min

• Functions:Min/Max/Average/Holdtofacilitatereadingsanalysis;memoryfor99readings

• Automaticshut-off• CaseIP40• Warrantyof2years

Code Description 922 BasickitincludestheFluke922, 2rubberhoses,4AAalkalinebatteries, usermanualandsoftcover

922KIT CompletekitincludestheFluke922, Pitottubeof12”,2rubberhoses, magneticToolPakcover,4AAalkalinebatteries usermanualandhardcase

CE-MANO-DIFF Calibrationwithcertificatefordifferentialmanometer

CE-MANO-DIFF-VIT Calibrationwithcertificatefordifferentialmanometer inpressureand2pointsvelocitywithPitottube.

KIMO Flush-mount multifunction pressure transmitterCPE 310-S• MeasuringRangesfrom-100to+100Pa1

• Accuracy:From-100to+100Pa:±0.2%ofreading±0.8Pa

• Accuracy:From-1000to+1000Pa:±0.2%ofreading±2Pa

• InputforinterchangeableprobeKimo(Class310,seep.21)

• Alternatingdisplayof1to3parameters• Frontfacecalibration• Configurableintermediateandcentre

zeroranges• 3audibleandvisualalarms• Frontfacekeypadallowingtoconfigurethe

transmitterandacknowledgethealarm• 3analogueoutputs0-5/10Vor0/4-20mA• Highresolutioninpressureonmodel

-100/+100Pa(ex:0.1Pa)(optional)• Outputsdiagnostic• MODBUSnetworkRS485

system(optional)• Frontfacemadeofbrushedstainlesssteel

withelectroluminescentdisplayt1Othermeasuringrangesavailableonrequest:from-1000to+1000Pa

Code Description Units Resolution CPE310-S Flush-mount Pa,mmH2O, 1Pa,0.1 differentialpressure, mbar,inWG, mmH2O,0.01 sensor-transmitter,t mmHG,daPa, mbar,0.01 ±100Pa,shippedwith hPa inWG,0.01 adjustingcertificate. mmHG,0.1 daPa,0.01hPa

OptionsOptional probes for:CO,CO2,RH+Temperature,Velocity,etc.

Code Description HRP Highresolution0,1Pa,.001inWGRS5 ModbusRS485communication, configurationanddatatransmissionLCC-S ConfigurationsoftwarewithUSBcableCA-CPE Adaptercableforinterchangeable probesCE-TRAN-PD-5P 5pointscalibrationcertificate

Page 14: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n14

P R E S S U R E C A L I B R A T o R SBETA Pressure CalibratorModel T-140• Accuracy:±0.05%FS±resolution• Highpressuredigitalmanometer• Staticordifferentialpressuremeasures• 2xnptfittings1/8"• Choiceofmeasureunits

Pressure Calibrator with Case, Kit test leads, 9V battery Manometer and Pump .±10inWC(0.3psid) T140-10W ±200inchesH2O T140-200WC T140-200WCK-14,00to30.00psig/psid T140-030 T140-030K-14,0to100.0psig/psid T140-100 T140-100K-14,0to300.0psig T140-300 T140-300K-14,0to3000psig T140-303 T140-303K

BETA Pressure ModulesFor Betagauge 325, DMC1410, MC1210, MC1010, BG321, BG311, BG301, BG330

Code Pressure Ranges 910331-001 0to1psig(67mbar)(nonisolated,dryonly)910331-003 0to0.3psig(10poH2O)(20mBar)(nonisolated,dryonly)910331-005 0to5psig(350mBar)(isolated,316SS)910331-007 0to7.2psig(500mBar)(isolated,316SS)910331-010 0to10psig(700mBar)(isolated,316SS)910331-015 0to15psig(1bar)(isolated,316SS)910331-030 0to30psig(2bar)(isolated,316SS)910331-050 0to50psig(3.5bar)(isolated,316SS)910326-100 0to100psig(7bar)(isolated,316SS)910326-150 0to150psig(10bar)(isolated,316SS)910326-300 0to300psig(20bar)(isolated,316SS)910326-301 0to1000psig(70bar)(isolated,316SS)910326-315 0to1500psig(100bar)(isolated,316SS)910326-303 0to3000psig(200bar)(isolated,316SS)910326-305 0to5000psig(333bar)(isolated,316SS)910326-500 0to500psig(0to34bar)(isolated,316SS)910327-005 0to-5psigvacuum(-350mBar)(nonisolated,dryonly)910327-015 0to-15psigvacuum(-1bar)(nonisolated,dryonly)910332-015 0to15psia(1bar)(isolated,316SS)910332-030 0to30psia(2bar)(isolated,316SS)910332-050 0to50psia(3.5bar)(isolated,316SS)910332-100 0to100psia(7bar)(isolated,316SS)910332-150 0to150psia(10bar)(isolated,316SS)910329-005 0to5psid(350mBar)(nonisolated,dryonly)910329-030 0to30psid(2bar)(nonisolated,dryonly)910329-050 0to50psid(3,5bar)(nonisolated,dryonly)910331-10K 0to10,000psig(0to700bar)(isolated,316SS)910333-015 -15to15psig(-1to1bar)(nonisolated,dryonly)910333-030 -15to30psig(-1to2bar)(nonisolated,dryonly)

BETA Pneumatic and Hydraulic Manual PumpsSeries MECPFor all pressure simulators and calibrators Code Description MECP100 Lowpressure/vacuumpneumatic pump,-28"hgto+100psi,1/8"npt MECP500 Highpressure/vacuumpneumatic pump,-29"hgto+500psi,¼"npt MECP10K Wateroroilpneumaticpump, 0to10.000psi,¼"nptAskit:withhardcase,pneumaticorhydraulichoseandfitting

MECP100KIT PumpandKitwithhardcaseMECP500KIT PumpandKitwithhardcaseMECP10KKIT PumpandKitwithhardcase

MECP100

MECP500 /10K

Martel Portable High pressure Pneumatic Hand Pump MECP2000

General Features• Generate-14psi(-0.9bar)to2000psi(140bar)

byhand• Precisionvernierallowsfineadjustmentat

bothhighandlowpressures• Ventvalveoffersprecisecontrolandvents

atthepressureconnectiontopreventpumpcontaminates

• Useasbothaportableorbench-toppump• Doubleoutputmanifoldwith1/4NPT

femalefittingsincludesBSPadapter• Ex.tremelyruggeddesign,willstanduptofielduse• Isolationvalveprotectspumpandincreases

finecontrolrange

How to orderCode Description 1919967 MECP2000PneumaticHandPumpwith 2x¼"BSPadaptersandTeflontape.

OPTIONS1010074 Highpressurehosekitincludes (2)1/4"NPTadaptersand(1)high pressurehosewithfingertightconnectors6161255 CarryingCase,highimpactresin injectedwater-resistant

PI-XXX High Accuracy Digital Gauges PI-PRO see page 6

Dwyer Wet/Wet Handheld Digital ManometerSérie 490

• Liquid&Gaspressuremeasurement• Accuracy±0.5%FS,60to78°F(16to26°C)

and±1.5%FSfortheremainderoftherange• 4digitsLCDof0.42"(10.6mm)• SS316Lconnections1/8"NPT/F• Memoryof40readings• Audibleandvisualoverpressurealarms• Fieldadjustablereadingdamping• Hosesandfittingssoldseparately

Model Range code Description Max Ovepressure 490 Digitalmanometer 1 0-15.00psi 30psig 2 0-30.00psi 60psig 3 0-50.00psi 100psig 4 0-100.0psi 200psig 5 0-500.0psi 1000psig 6 0-200.0psi 500psig

3V Option:Manometerwith 3-wayvalvewithbleed (100psimax)

A-402A Carryingcase

CE-MANO-DIFF Calibrationwithcertificatefordifferentialmanometer

Page 15: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 15

C A L I B R A T o R SBETA/MARTEL Digital Calibrator ManometersSeries 301, 311A, 321A

Standard specifications• Choiceofunitsforeachchannel: psi,inH2O,(4°C,20°C,60°F),cmH2O,Bar,

mBar,kPa,MPa,inHg,mmHg,kg/cm²• Pressureshut-offtest• Memoryforupto5configurations• Simple,solidandcompact;workswith4AAstandardbatteries• Standardaccessories:softcover,batteries,usermanual,

NISTcertificateandtestleads• RTDinputforrequiredtemperaturewithelectronicflowmeters.

Calculationin%oferrorandamortization(exceptfor301)

Range:0to24,000mA(measuringonly)±0.015%FS±0.002mARange:0to30,000Vcc(measuringonly)±0.015%FS±0.002VRange:RTD,-40to105°C(-40to220°F)±0.015%V.M.±0.02ohms

Model BetaGauge 301• Calibrator/pressurereadertoaninternaltransmitter.Possibilityofasecond

transmitterusinganadapterforBETApressuremodules.Accuracy:±0.05%FSInternal ranges available:1,5,30,100and300psi(ranges30and100psi

arecalibratedfrom-12psitofullscale)Model BetaGauge 311A• Calibrator/pressurereadertoaninternaltransmitterwithspecialfunctionsto

calculatethemassflow.PossibilityofasecondtransmitterusinganadapterforpressuremodulesBETA.Upto3readingssimultaneously,pressure,loop4-20mA(withsupply24Vcc),RTDprobeandvoltageCC

Accuracy:±0.025%FS(from15to3000psi)or±0.035%FS(5,5000and10000psi)

Ranges available:0.4,1,5,7,15,30,100,300,500,1000,3000,5000and10000psiModel BetaGauge 321A• Calibrator/two-channelpressurereader.Possibilityofathirdchannelusingan

adapterforBETApressuremodules.Uptothreesimultaneousmeasures,loop4-20mA(withsupply24Vcc)RTDandvoltageCC

Accuracy:±0.025%FS(from15to3000psi)or±0.035%FS(5,5000and10000psi)Ranges:(choiceof2)5,15,30,100,300,500,1000,3000,5000and10000psi

S.I.versionavailablefor311Aand321A.ExiaIIBT3Gb(Ta=-10..+45°C)KEMA10ATEX0168X0344,II2GIECExCSA10.0013X

Code Description BG301-[range] BetaGauge301withchosenrange

BG311A-[range] BetaGauge311Awithrangebetween 5and5000psi,aschosenBG311A-[range] BetaGauge311Awithrangeofmore than5000psi,aschosenBG311A-EX-[range] Versionintrinsicallysafe,aschosen, 5to5000psiBG311A-EX-[range] Versionintrinsicallysafe,aschosen, atmorethan5000psi

BG321A-[range]/[range] BetaGauge321Awithtworangesofyour choice,2to5000psiBG321A-[range]/[range] BetaGauge321Awithtworangesofyour choice,atmorethan5000psiBG321A-EX-[range]/[range]Versionintrinsicallysafewithtworanges ofyourchoice,2to5000psiBG321A-EX-[range]/[range]Versionintrinsicallysafewithtwochosen ranges,atmorethan5000psi

910951-001 AdaptermoduleBPPA-100;pressure modulesextra,seepage13LTP-100A RTDprobe

AllavailableinKITwithpneumaticorhydraulicpump,RTDprobe(exceptBG301).Seepage13forpumpsandexternalmodules.

BetaGauge 321A

BetaGauge 311A

BetaGauge 301

BETA/MARTEL Calibrator with Electric PumpModel BetaGauge 330Calibrator/pressurereadertointernalsimilator.

ThenewBetaGauge330offersmanypracticalfeatures.

Shut-offtestsmaybedonewithinternalaswellaswithExternalpressuremodule.Thefunctionsoferrorpercentage(%)anddepreciation(ouamortization)areincluded.The330maysaveanddisplayuptofiveofthemorefrequentlyusedsettings,usingonlyasoleremainderbutton.RangesAvailable PressurePSIG: -12to30psi/-0.8to2bar -12to150psi/-0.8to10bar -12to300psi/-0.8to20barPSIA: 0to30psia/0to2barA 0to150PSIA/0to10barAmA 0to24mA,max.charge000OhmsRTD Pt100,-50to150°C

AccuracyPressure ±0.035%offullscaleforinternal transmitter;itvariesaccordingtothe externaltransmittersmodule. Add0.002%FS/°Cwhennotinrangefrom15to35°CmA ±0.015%ofreading±2results(simulationandmeasure)Volts ±0.015%ofreading±2results(measureonly)Temperature±0.1°C(0.2°F)(measureonly)(Pt100RTD)

All above-mentioned instruments are shipped with:

Code Descriptiion BG330-30 CalibratorwithelectricpumpRange-12to30psiBG330-150 CalibratorwithelectricpumpRange-12to150psiBG330-300e CalibratorwithelectricpumpRange-12to300psiBG330-30A CalibratorwithelectricpumpRange0to30psiABG330-150A CalibratorwithelectricpumpRange0to150psiA

LDT-500liquid/dusttrap,NISTtraceablecalibrationcertificate,batteries,usermanual,testcables,qualitysoftcover,testtubeandfittings

Page 16: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n16

KIMO Multifunction InstrumentModels AMI 310Interchangeable measurement modules1device=severalpossiblerangesandparametersWireless connectionDevice/probewirelessconnectionSmart-2014 systemWirelessandwiredprobesautomaticallyrecognized

Key features• Measurementofhygrometry,temperature,CO2,

CO,airvelocity,airflow,pressure,tachometry(dependingonmodelandprobe),WBGTcalculation,lightlevels,gasleakdetection

• Interchangeablemodules• Expandablememorywithmicro-SDcard• 2inputsforPt100temperature• Upto6measurementssimultaneously• Psychrometer• Largecolourdisplay

AMI310instrumentshavethefollowingfunctionsforthemeasurementsofpressure:

Automaticautozerobysolenoidvalve(AMI310PRO,PRF)•Manualautozero(AMI310CLA,STD,CRFandSRF)•Pressureintegration(0to9)•Point/pointaverage•Automaticpoint/pointaverage•Automaticaverage

AMI310instrumentshavethefollowingfunctionsforthemeasurementofairvelocityandairflow:

SelectionofthePitottubeorDebimobladeorcoefficient•Selectionofthesection•Selectionoftheunit•Automaticormanualtemperaturecompensation•Manualatmosphericpressurecompensation•Kfactor,K2factor

DESCRIPTIONConnections 2mini-DINconnectionsSMART-2014probesand1

micro-USBportforchargingandPCconnectionPower supply Lithium-IonbatteryAutonomy 57hwithhygrometryprobeStorage Upto1000datasetof20000pointsintheinternalmemory

+4GBmicro-SDcardOperating temperature From0to+50°CStorage temperature From-20to+80°CAuto shut-off Adjustablefrom15to120minutesorOffWeight 485gLanguages French,English,Dutch,German,Italian,Portuguese,Swedish,

Norwegian,Finn,Danish,Chinese,JapaneseThenewprobesuseauniquepluggablemini-DINcablethatfitsoneveryprobe.

Code Description AMI310 Supplied withoutprobeswith2cableswithMini-Dinconnectorfor measuringprobes(inoption),2lithium-ionrechargeablebatteries, withUSB/mainsadaptercable,MicroSDboardfordatastorage, 2x1mofsiliconetube4x7,onestainlesssteeltubediameter6mm, length100mm,adjustmentcertificateandtransportcase.AccessoriesLPC-14 SoftwareforPCconnectionforClass210/310portableinstrumentsSAD Transportback-pack.fForClass210/310instrumentsandtheiraccessoriesCSM Braidcablewithmini-Dinmaleconnector.FormeasuringandPT100 temperatureprobesBAT 23 Lithium-ionrechargeablebatteries.ForClass210and310instrumentsCAB 23 USBcablewithmainsadaptorcable,forBATrechargeablebatteryof Class210and310KIMP-23 Remoteprinter,infraredconnection,printingonthermalpaper, with10-yearwarrantyCQ-IMP Magneticprotectivecoverforremoteprinterofportableinstruments(KIMP-23)RTE Ø16mmtelescopicextension,length1m,swivellingat+/-90°. FormeasuringprobeswithhandlePRST Adjustablerodfrom100to300mm.Forprobesandtelescopicextension

A I R V E L o C I T Y A N D A I R F L o W

See Probes, page 17, and Modules above.

KIMO INTERCHANGEABLE MODULESFor portables Class 210 and 310

Code Description Pressure MPR 500 from-500to+500Pa MPR 2500 from-2500to+2500Pa MPR 10000 from-10000to+10000Pa MPR 500 M from-500to+500mBar MPR 2000 M from-2000to+2000mBar4-Channel Temperature M4TC K:from-200to+1300°C J:from-100to+750°C T:from-200to+400°CClimate module MCC Relative humidity from5to95%RH Temperature from-20to+80°C Barometric pressure from800to+1100hPa

KIMO AMI 300 KITSCode Description AMI310CLA Supplied withhotwireprobe(0.15to30m/s),ABShygrometryprobe (3to98%RHand-20+80°C),Ø70mmvaneprobe(0.4to35m/s), 2cableswithMini-Dinconnectorformeasuringprobes(inoption), 2lithium-ionrechargeablebatteries,withUSB/mainsadaptercable, microSDboardfordatastorage,2x1mofsiliconetube4x7,one stainlesssteeltubediameter6mm,length100mm,calibration certificateandtransportcase.AMI310STD Supplied withpressuremodule(-10000+10000Pa,4to100m/s), hotwireprobe(0.15to30m/s),ABShygrometryprobe(3to98%RH and-20+80°C),Ø100mmvaneprobe(0.3to35m/s),Pitottube length300mm,diameter6mm,2x1msiliconetube(blackandwhite), stainlesssteeltubeØ6mm,length100mm,2cableswithMini-Din connectorformeasuringprobes(inoption),2lithium-ionrechargeable batteries,withUSB/mainsadaptercable,microSDboardfordata storage,calibrationcertificateandtransportcase.AMI310PRO Supplied withpressuremodule(-500+500Paand2to28m/s), telescopichotwireprobe,length1m,withgraduation,swivellingat 90°(0.15to30m/s),stainlesssteelhygrometryprobe(3to98%RH and-40+180°C),Ø100mmtelescopicvaneprobe,length1m, swivellingat+/-90°(0.3to35m/s),Pitottubelength300mm,Ø 6mmwithintegratedTCKtemperatureprobe,2x1mofsilicone tube(blackandwhite),stainlesssteeltubeØ6mmlength100mm, 2cableswithmini-Dinconnector,formeasuringprobes,2lithium-ion rechargeablebatteries,withUSB/mainsadaptercable,Micro-SD boardfordatastorage,calibrationcertificateandtransportcase.AMI310CRF Supplied withhotwireprobe(0.15to30m/s),ABSwireless hygrometryprobe(3to98%RH-20+80°C),Ø70mmwireless vaneprobe(0.4to35m/s),2cableswithmini-Dinconnector,for measuringprobes,2lithium-ionrechargeablebatteries,withUSB /mainsadaptercable,Micro-SDboardfordatastorage,2x1mof siliconetube4x7,onestainlesssteeltube,diameter6mm,length 100mm,calibrationcertificateandtransportcase.AMI310SRF Supplied withpressuremodule(-10000+10000Paand4to 100m/s),hotwireprobe(0.15to30m/s),ABSwirelesshygrometry probe(3to98%RH-20+80°C),Ø100mmwirelessvaneprobe (0.3to35m/s),Pitottubelength300mm,diameter6mm,2x1m silicone(blackandwhite),stainlesssteelØ6mmtubelength100mm, 2cableswithmini-Dinconnector,formeasuringprobes,2lithium-ion rechargeablebatteries,withUSB/mainsadaptercable,Micro-SD boardfordatastorage,calibrationcertificateandtransportcase.AMI310PRF Supplied withpressuremodule(-500+500Paand2to28m/s), telescopichotwireprobe(0.15to30m/s)length1m,withgraduation, swivellingat90°,stainlesssteelwirelesshygrometryprobe(3to 98%RH-20+80°C),Ø100mmwirelessvaneprobe(0.3to35m/s), Pitottubelength300mm,diameter6mmwithintegratedTCK,2x1m silicone(blackandwhite),stainlesssteelØ6mmtube,length100mm, 2cableswithmini-Dinconnector,formeasuringprobes,2lithium-ion rechargeablebatteries,withUSB/mainsadaptercable,Micro-SD boardfordatastorage,calibrationcertificateandtransportcase.

KITS READY TO GO

Page 17: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 17

A I R V E L o C I T Y A N D A I R F L o W

Code Measuring units Ranges Accuracies Compatible with

SFC 300

SFC 900

SFC 900 GN

Airvelocity:m/s,fpm,km/hAirflow:m3/h,cfm,l/s,m3/s

From0.15to1m/s(optionnal) ±2%ofreading±0.03m/s

MTP210

VT210

AMI310

From0.15to3m/sFrom3.1to30m/s

±3%ofreading±0.03m/s±3%ofreading±0.1m/s

Débit:m3/h,cfm,l/s,m3/s 0to99999m3/h ±3%ofreading

Température°C,°F From-20to+80°C±0.3%ofreading±0.25°C

SOM 900

Airvelocity:m/s,fpm,km/h From0.00to5.00m/s ±3%ofreading±0.05m/s

HQ210

AMI310RelativeHumidity%RH From5to95%RH

Accuracy(Repeatability,linearity,Hysteresis):±1.8%RH(from15°Cto25°C)

Factorycalibrationuncertainty:±0.88%RHTemperaturedependence:±0.04x(T-20)%RH(ifT<15°CorT>25°C)

Temperature°C,°F From-20to+80°C ±0.3%ofreading±0.25°C

KIMO ProbesFor 210 and 310 portables.

Hot Wire / Telescopic Hot Wire / Telescopic Hot Wire with Goose-neck Probes

Omnidirectional Telescopic Probe

SH 14 SHT 14

Airvelocity:m/s,fpm,km/hFrom0to3m/s

From3.1to25m/s

From0.8to3m/s±3%ofreading±0.1m/s±1%ofreading±0.3m/s MTP210

VT210

AMI310Airflow:m3/h,cfm,l/s,m3/s 0to99999m3/h ±3%ofreading

Temperature°C,°F From-20to+80°C ±0.4%ofreading±0.3°C

ø14 mm Vane Probe / ø14 mm Telescopic Vane Probe

Ø70 mm Vane Probe / ø70 mm Telescopic Vane Probe / Ø70 mm RF Vane Probe

ø100 mm Vane Probe / ø100 mm Telescopic Vane Probe / Ø100 mm RF Vane Probe

SH 70

SHT 70

SHF 70

Airvelocity:m/s,fpm,km/hFrom-5to3m/s

From3.1to35m/s

From0.4to3m/s±3%ofreading±0.1m/s

±1%ofreading±0.3m/sMTP210

VT210

AMI310Airflow:m3/h,cfm,l/s,m3/s 0to99999m3/h ±3%ofreading

Temperature°C,°F From3.1to35m/s ±0.4%ofreading±0.3°C

SH 100

SHT 100

SHF 100

Airvelocity:m/s,fpm,km/hFrom-5to3m/s

From3.1to35m/s

From0.3to3m/s±3%ofreading±0.1m/s

±1%ofreading±0.3m/s MTP210

VT210

AMI310Airflow:m3/h,cfm,l/s,m3/s 0to99999m3/h ±3%ofreading

Temperature°C,°F From-20to+80°C ±0.4%ofreading±0.3°C

SFC 300

SOM 900

SH 14

SHT 14

SH 70

SH 100

SHT 70

SHT 100

SFC 900

SFC 900 GN

Page 18: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n18

A I R V E L o C I T Y A N D A I R F L o W

CO • temperature

Sonde CO2 • Température et CO2 • Température • Hygrométrie

Gaz Leak Probe

SCO 110

Temperature°C,°F From-20to+80°C ±0.3%ofreading±0.25°C HQ210

MP210

AMI310CO:ppmFrom0to200ppm

From200to500ppm

±3ppm

±1.5%ofreading

Code Utilisation Plages Précision Appareils compatibles

SCO 112

SCOH 112

Temperature°C,°F From-20to+80°C ±0.3%ofreading±0,25°C

HQ210

AMI310

CO2:ppm From0to5000ppm ±3ppm±50ppm

SCOH 112 Hygro:% From5to95%HR

Accuracy(Repeatability,linearity,Hysteresis):

±1.8%HR(from15°Cto25°C)Factorycalibrationuncertainty:±0.88%RHTemperaturedependence:±0.04x(T-20)%RH(ifT<15°CorT>25°C)

SFG 300

ppm

%LEL

%VOL

From0to10000ppm(GPL:0-1800)

From0to20%LEL

From0to1%VOL

±20%offullscaleMP210

AMI310

KIMO Sondes de mesurePour portables 210 et 310 suite...

Multifunction Probe

Hygrometry / High Temperature Hygrometry / RF Hygrometry

SMT 900

Airvelocity:m/s,fpm,km/hFrom0.15to3m/sFrom3.1to30m/s

±3%ofreading±0.03m/s

±3%ofreading±0.1m/s

MTP210

VT210

AMI310

Airflow:m3/h,cfm,l/s,m3/s 0to99999m3/h ±3%ofreading

RelativeHumidity%RH From5to95%RH

Accuracy(Repeatability,linearity,Hysteresis):±1.8%RH(from15°Cto25°C))Factorycalibrationuncertainty:±0.88%RH

Temperaturedependence:

±0.04x(T-20)%RH(ifT<15°CorT>25°C))

Temperature°C,°F From-20to+80°C ±0.3%ofreading±0.25°C

SHR 110 SHRF 110

SHR 300 SHRF 300

RelativeHumidity%RH From3to98%RH

Accuracy(Repeatability,linearity,Hysteresis)::±1.5%RH(from15°Cto25°C))Factorycalibrationuncertainty:±0.88%RHTemperaturedependence:

±0.04x(T-20)%RH(ifT<15°CorT>25°C) HQ210

VT210

AMI310Dewpoint°Ctd,°Ftd From-50to+100°Ctd ±0.6%ofreading±0,5°Ctd

SHR 110 SHRF 110

Temperature°C,°F From-20to+80°C ±0.3%ofreading±0.25°C

SHR 300 SHRF 300

Temperature°C,°F From-40to+180°C ±0.3%ofreading±0.25°C

SMT 900

SHR 110

SHR 300

SCO 110

SCO 112

SCOH 112

SFG 300

Page 19: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 19

A I R V E L o C I T Y A N D A I R F L o W

Optical and Contact Tachometry

Lightmeter Probe

Code Utilisation Plages Précision Appareils compatibles

STAOptical:tr/min,rpm

From60to10000tr/min

From10001to60000tr/min

±0.3%ofreading±1tr/min

±30tr/minMP210

VT210

AMI310Contact:tr/min,rpm From30to20000tr/min ±1%ofreading±1tr/min

SLU lx,klx,fcFrom0to150000lx

From0to13935fc±2%ofreading±3lux

HQ210

AMI310

KIMO Sondes de mesurePour portables 210 et 310 suite...

Accessoires supplémentaires KIMO

MCU Ucoefficientmodule(thermaltransfertofawall),thermocoupletypeT-20to+80°C,°C/F,W/m2

SAD Transportback-pack

RTE Telescopicextension,1mbendableto90°

RTE-2 Telescopicextension,2mbendableto90°,forradiofrequencyprobe(FP)only

KIMP23 Infraredprinter

STA

SLU

MCU

RTE-2

RTE

KIMP 23

Page 20: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n20

A I R V E L o C I T Y A N D A I R F L o W

Kimo K25

Kimo K85

KIMO Vane Thermo-AnemometerModel LV130

• Airflowcalculation(andatthecone)•Detectionofflowdirection• Automaticaverage• Selectionofunits(airvelocity,airflowandtemperature)• Displayofminimumandmaximumvalues• Adjustableautoshut-off• Backlight• Holdfunction

Comeswithacalibrationcertificate*andacarryingcase(classScomeswithanadjustingcertificate).

SpecificationsVELOCITYm/s,fpm, From0.3to35m/s(60to6990ft/min) From0.30to3.00m/s: ±3%orreading±0.1m/s km/h From3.1to35m/s: ±1%ofreading±0.3m/sAIR FLOW

m³/h,cfm, From0to99999m³/h ±3%ofreading±0.03area(cm²)l/s,m³/s

TEMPERATURE

°C,°F From0to+50°C(-32to122°F) ±0.4%ofreading±0.3°C

Code Description LV 130 IntegratedØ100mmVane*LV 130S IntegratedØ100mmVane

KIMO Vane Thermo-AnemometersModels LV111 – LV117 – LV110

Functions• Airflowcalculation• Airflowcalculationwithcone(LV110/117)• Automaticaverage• Selectionofunits(airvelocity,

airflowandtemperature)• Configurableautoshut-off• Backlight• Detectionofflowdirection(LV110/117)• Holdfunction-min-maxComeswithacalibrationcertificateandacarryingcase(class110Scomeswithanadjustingcertificate)

Specifications VELOCITY ACCURACYLV 111 Ø14 mm From0.8to25m/s From0.80to3.00m/s:±3%ofreading±0.1m/s (155to4920ft/min) From3.1to25m/s:±1%ofreading±0.3m/s

LV 110 Ø100 mm From0.3to35m/s From0.30to3.00m/s:±3%ofreadinge±0,1m/s (60to6990ft/min) From3.1to35m/s:±1%ofreading±0.3m/s

LV 117 1Ø0 mm From0.40tto35m/s From0.40to3.00m/s:±3%ofreading±0.1m/s (80to6990in/min) De3,1à35m/s:±1%ofreading±0.3m/s

AIR FLOW ACCURACYAll models From0to99999m³/h ±3%ofreading±0.03area(cm²) (cfm,l/s,m³/s)

TEMPERATURE ACCURACYAll models From-20to+80°C ±0.4%ofreading±0.3°C (-4to176°F)

Code Description LV 111 RemoteprobeØ14mm,cable2mLV 111SRemoteprobeØ14mm,cable2mLV 110 RemoteprobeØ100mm,cable2mLV 110SRemoteprobeØ100mm,cable2mLV 117 RemoteprobeØ70mm,cable2mLV 117S RemoteprobeØ70mm,cable2m

KIMO Hot Wire Thermo-AnemometerModel VT50• Holdfunction• Autoshut-off:20minutes• Hotwireprobe• 4xAAAbatteriesComeswithadjustingcertificateandcarryingcase.

Order Code VT50

Temperature Air velocity From-20to+80°C(-4to+176°F) 0.15to30m/s(30to6000pi/min)

Accuracy ±0.3%ofreading±0.25°C From0.15to3m/s:±3%ofreading±0.05m/s From3.1to30m/s:±3%ofreading±0.2m/sResolutiion 0.1°C From0to3m/s:0.01m/s From3to30m/s:0.1m/sResponse T90=1sforv=1m/s T63=6stime

KIMO Compact Vane Thermo-AnemometerModel LV50• Holdfunction• Autoshut-off:20minutes• Integratedvaneprobe• 4xAAAbatteries

Comeswithadjustingcertificateandcarryingcase

Order Code LV50 Ø100mm

Temperature Air Velocity From-20to+80°C(-4to+176°F) 0.3to35m/s(60to6990pi/min)Accuracy ±0.4%ofreading±0.3°C From0.3to3m/s:±3%ofreading±0.1m/s From3.1to35m/s:±1%ofreading±0.3m/sResolutiion 0.1°C From0.3to3m/s:0.01m/s From3to35m/s:0.1m/sResponse T63=5s T63=4stime

Accessories for Class 50 and 110 Instruments

Code Description CQ 15 Protectivecoverwithintegratedmagnets. ForClass50and110instruments

MT51 ABStransportcase.ForClass50and110instruments

RD300 StraightextensionØ10mm,length300mm.Forhotwireprobeand diam.14mmvaneprobe

RTE TelescopicextensionØ16mm,length1m,canbebentat+/-90°. FormeasuringprobeswithhandleK25 AirflowconeforØ100mmvaneprobe.Sizes:200x200mm. Airflowfrom10to300m³/h,blowandexhaust.Suppliedwithsoftcover.K85 Airflowconefordiameter100mmvaneprobe.Size:350x350mm Airflowfrom10to400m3/h,blowandexhaust.Suppliedwithsoftcover.

Page 21: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 21

A I R V E L o C I T Y A N D A I R F L o WALNOR Vane AnemometerModel RVA801ThevaneanemometerRVA801islight,sturdyandeasytouse.Italwaysgivesaccurateanddependablemeasures.Theidealtooltobeusedingrilles,ductanddiffusers.Displaysinmetricorimperialunits.

The RVA501Aportablevaneanemometerformeasuringairvelocityandairflow.

Velocity 50to6000ft/min,0.25yo30m/sAccuracy ±1%ofmeasureor±4ft/min (±0.02m/s),thehighestofthe2Duct dimensionsRVA501 0to173.6ft²,(0to16m²)RVA801 0.043to900ft²,(0.00399to90m²)Air flow dependingonairvelocityandductdimensionsTemperature 0to60°C(32to140°F)Accuracy±0.6°C,±1°F

Data logging (RVA501 only)Memory 12.700+samplesand100testsfilesMeasuring intervals 1secondto1hourTime constant adjustablebyuser(RVA501only)

Code Description RVA801 Anemometerwithintegratedvane100mm,rigidcarrying case,batteries,NISTcertificateandusermanualRVA501 Vaneanemometer100mm,rigidcarryingcase,USBcable, LogDat2software,manualandautomaticdatalogging, batteries,NISTcertificateandusermanual801750 AirconeAlnorkit,rectangularandroundcones801761 UniversaladaptorAC801748 TelescopicextensionforRVA501

ALNOR Hot Wire AnemometersModels AVM430 and AVM440

Velocity 0to6000ft/min,0to30m/sAccuracy1&2 ±3%ofmeasureor ±3ft/min(±0.015m/s), whicheveristhegreatestAccuracy 1ft/min,0.01m/sDuct dimensions 1.0to250.0inches(1.0to635.0cm)Air flow dependingonairvelocityand ductdimensionsTemperature AVM430 -18to93°C,0to200°F AVM440-10to60°C(14to140°F)Accuracy3 ±0.3°C,±0.5°FResolution 0,1°Relative humidityAVM440 only 0to95%RHAccuracy4 ±3%Resolution 0.1%Data loggingMemory 12,700+samplesand100testsfilesMeasureinterval 1secondto1hourTime constant adjustablebyuser

Code Description AVM430 Hotwireanemometer,rigidcarryingcase,USBcable andLogDat2software,manualdatalogging,batteries, NISTcertificateandusermanualAVM430A Hotwireanemometer,articulatedprobe,rigidsuitcase, USBcableandLogDat2software,manualdatalogging, batteries,NISTcertificateandusermanualAVM440 Hotwireanemometer,rigidsuitcase,USBcableand LogDat2software,manualandautomaticdatalogging, batteries,NISTcertificateNISTandusermanualAVM440A Hotwireanemometer,articulatedprobe,rigidcarryingcase, USBcableandLogDat2software,manualandautomatic datalogging,batteries,NISTcertificateandusermanual801761 UniversaladaptorAC

KIMO Hot Wire Thermo-anemometerModel VT110• 0.15to30m/s(30to6000pi/min);From0.15to3m/s:

±3%ofreading±0.05m/s,From3.1to30m/s:±3%ofreading±0.2m/s

• From-20to+80°C(-4to+176°F),±0.3%ofreading±0.25°C

• Airflowcalculationwithcone• Selectionofunits(airvelocity,airflowandtemperature)• Holdfunction,Displayofminimumandmaximumvalues• Adjustableautoshut-off• Backlight• Airflowdirectiondetection• Automaticaverage• Airvelocitycompensationinatmosphericpressure

Code Description VT110S Hot-wireanemometerwithSSprobeVT110 Hot-wireanemometerwithSSprobeVT115S Hot-wireanemometerwithtelescopicbendable90°SSprobeVT115 Hot-wireanemometerwithtelescopicbendable90°SSprobe

Comeswithacalibrationcertificate(except"S"modelscomewithanadjustingcertificate)andcarryingcase.AccessoriesCode Description K35 Cone200x200mmK75 Cone300x300mmK120 Cone450x450mmK150 Cone550x100mm

RVA801

RVA501

801750

Code Description VT210L / VT210 TL Anemometerwithvaneprobe100mmSH100 ortelescopicSHT100-980to7000pi/min, 0to99999cfmVT210H / VT210 TH Anemometerwithvaneprobe70mmSH70 ortelescopicSHT70-980to7000pi/min, 0to99999cfmVT210P / VT210 TP Anemometerwithvaneprobe14mmSH14 ortelescopicSHT140to5000pi/min, 0to99999cfmVT210F / VT210TF AnemometerwithhotwireprobeSFC300 orSFC900(telescopic)0to6000pi/min, 0to99999cfmVT210M AnemometerwithmultifunctionprobeSMT900, telescopic,velocityandhumidity0to6000pi/min, 0to99999cfm,5to95%HRLPC-2014 Dataloggersoftwareversion2014

Thermo-Hygrometer-Anemometer (New)Model VT210• Measurementoftemperature,hygrometryandairvelocity(dependingonmodels)• Interchangeable modules• TwoPt100temperatureinputs• Upto6simultaneouslymeasurements• Large:Graphicscreen• Connections:2mini-DINconnections

SMART-2014probesand1micro-USBportforchargingandPCconnection

• Power supply: Lithium-Ionbattery• Autonomy:44hwithhotwireprobe

/65hwiththermocouplemodule• Memory capacity: Upto1000datasetof20000points• Operating temperature:From0to+50°C• Storage temperature: From-20to+80°C• Auto shut-off:Adjustablefrom15to120minutesorOff• Multilingual:French,English,etc.

The instruments are supplied in a transport case with a calibration certificate, a charger and a USB cable..

See Probes at pages 17-18-19

Page 22: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n22

A I R V E L o C I T Y A N D A I R F L o WKIMO Digital FlowmeterModel DBM610

• Measuringrangeof40to+3500m3/h• Hoodchangingsystemsimpleandfast• ReadingsoperatingsoftwareonPC(Datalogger10)• Reliable,light,solideasytohandle• Removablecase• Interchangeablehoods

FUNCTIONS• Simultaneousdisplayofflowandtemperature• Automaticflowdirection(extractionorblowing)• Automaticaverageandpointbypointaverage• HOLDfunction(setsreading)• Removablecase(micromanometerfunction)• PCoperatingthankstoUSBinterface• Choiceoflanguages

ALNOR Digital Balometer - MicromanometerModel EBT731Balometerwithremovablemultifunctonmicromanometer• Flow25to2500ft³/min(42to4250m³/h); ±3%VM±7ft³/min• Speed25to15000ft/min (withPitottube)• Differentialrange±15inH2O(3735Pa); resolutionof0.00001inH2Oandaccuracy

of±2%VM±0.001inH2O• Absolutepressure14to40inH2O

((356to1016Hg))• 0to95%HR(optionalprobe)and -40to121°C(dependingonprobe)• Memoryof26500measures

(transfersoftwareincluded),includingminimum,maximumandaverage,continuousorintervalacquisition(10to600seconds)

• Guarantyof2years

Code Description EBT731 Hood2x2ft,baseforbalometer,micromanometer, 4AArechargeablebatteries,externalcharger,ACadaptor, Pitottube18",2staticpressureprobes, Neoprene16feethose,caseonwheel, Compudat™transfersoftware,NIST certificateandusermanual

Additional accessories and probes 801206 Hoodsandframes2x4ftand1x4ft 801207 Hoodsandframes3x3ftand1x5ft 801090 X-sensor,16points 800187 AirFlowairvelocityprobe 800220 Humidity-temperatureprobe

Specifications

FLOWMeasuringrange from40to+3500m3/hAccuracy 3%ofreading±10m3/hhTEMPERATURE (on base)Measuringrange from0to50°CAccuracy 2%ofreading±0.1°CTTEMPERATURE THERMOCOUPLE (on case)Thermocouple K,J,T,SMeasuring ranges K: from -200 to 1300°C J: from -100 to 750°C T: from -200 to 400°C S: from 0 to 1760°CPRESSUREMeasuringrange from-2500to+2500PaAccuracy ±0.2%ofreading±2Pa

General SpecificationsConformity Electromagneticcompatibility

(StandardNFEN61326-1)Supply 4alkalinebatteriesLR6; RechargeablebatteryLi-ion, 3.7V4400mhA(option)Model Description DBM610 Withhood610x610mmDBM610C Flowmeterwith5hoodsHO610 610x610mmHO1020 1020x1020mmHO720 720x720mmHO713 720x1320mmHO415 420x1520mm

ALNOR ANALOG BALOMETERModel ABT701Features• Analogdisplay,easytoread,fastmeasuring• Easytocarrythankstoastronghandle

inthemiddle• Ergonomicdesign,ultralight;easilymanageable

byoneperson• Differenthoodsofdifferentsizesavailable• Holdingofmeasures• On-wheelscarryingcase,likeasuitcaseDescriptionAnalogbalometers,modelsABT701/ABT703/ABT711/ABT713Input and output rangesFrom30to1000CFM(ft3/min),50to2000MCH(m3/h)AccuracyAABT701/ABT703±3%ofchosenfullscale+5CFM(ft3/min)ABT711/ABT713±3%ofchosenfullscale+10MCH(m3/h)UnitsABT701/ABT703CFM(ft3/min)ABT711/ABT713MCH(m3/h)SupplyFour(4)alkalineAAbatteriesWeight with batteries:7.4pounds(3.4kilos)

Code Description ABT701 30to1000CFM(ft3/min)with2ftx2ft (610mmx610mm)hoodABT703 30to1000CFM(ft3/min)with16inx16in (406mmx406mm)hoodABT711 50to2000MCH(m3/h)with2ftx2ft (610mmx610mm)hoodABT713 50to2000MCH(m3/h)with16inx16in (406mmx406mm)hoodIn option: kits of hood and frame8010972ftx2ft(610mmx610mm)8012012ftx4ft(610mmx1220mm)8012001ftx4ft(305mmx1220mm)8012021ftx5ft(305mmx1525mm)8012033ftx3ft(915mmx915mm)80120916inx16in(406mmx406mm).

CH-Stand960 Straightprobeforairvelocityandtemperature962 Flexibleprobeforairvelocityandtemperature964 Straightprobeforairvelocity,temperatureandhumidity966 Flexibleprobeforairvelocity,temperatureandhumidity8934 WirelessprinterBluetoothCH-Stand Standforthehood

Accessories for ABT701 and EB731

Page 23: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 23

A I R V E L o C I T Y A N D A I R F L o W

CTV110

Sensors-transmitters, Class CTV 110• IP65case• ABSVOmaterialaccordingtoUL94• Withorwithout10digitsdisplay

(switchingbetweenvelocityandtemperature) dimensions50x17mm• Range:from0-30m/sandfrom0to50°C0-6000ft/min,

±3%ofreading±0.3m/s(60ft/min)• Range:0to+50°C,-20to+80°C,

-50to+50°C,0to+100°C±0.3%ofreading±0.25°C;°Cor°F

• ProgrammablerangesviasoftwareorDIPswitch• Output:0-10V4-20mAactive;

supply:VAC/cc(3-4wires)• Outputs: from0to5m/s,from0to10m/s,from0

to15m/s,from0to20m/sandfrom0to30m/s• Accuracy: from0to3m/s:±3%ofreading±0.05m/s; from3to30m/s:±3%ofreading±0.2m/s• Measure unit: m/sandfpm

Description Supply/Output Aactive-24VAC/cc,4-20mA3-4wires Vactive-24VAC/cc,0to10VAssembly Aback Dcableextensionupto2mDisplay Owithdisplay NwithoutdisplayProbe length 150mm 300mm

CTV110 -

LCC-S Configuratonsoftwareformonostats andsensorsClass110/210/310,with manualandUSBcable

Sensors-transmitters Class CTV 210• Programmablerangesfrom0to30m/s

(modelwithhotwireprobe)andfrom0to5m/s(modelwithomnidirectionalprobe)

• Programmablerangefrom0to50°Ctemperature• Flowfunction• Analogoutput4wires0-5/10Vor0/4-20mA• Supply24VCC/VACou115/230VAC• Directionpointer• ABSV0IP65case,withorwithoutdisplay• Mount:¼ofturnonwallfixationplate• Material:ABSV0,UL94standard• Protectionrating:IP65• Screen:75x40mm,LCD20digits,2linesFeaturesRange: from0to+50°C/°FAccuracy:±0.3%ofreading±0.25°CResponse time:T90=0.9secondforVair=1m/sMeasuring span: standardmodel:from0to30m/s omnidirectionalmodel:from0to5m/sAccuracy: Standardmodel: from0.15m/sto3m/s:±3%ofreading±0.03m/s from3to30m/s:±3%ofreading±0.1m/s Omnidirectionalmodel:

from0to5m/s:±3%ofreading±0.05m/sSupply: 24VAC/VCC±10or

115VACor230VAC±10%,50-60HzOutputs: 2x4-20mAor2x0-20mAor2x0-5Vor2x0-10V(4wires) maximumcharge:500Ohms(0/4-20mA) minimumcharge:1KOhms(0-5/10V)

CTV210

STV-150 Hot wire probeSTV-OMNI

Omnidirectional probe

Description Supply / Output B24VAC/cc0-10Vor4-20mA H115or230VAC0-10Vor4-20mADisplay Owithdisplay NwithoutdisplayProbe length S O

CTV210 -

KIMO Hot Wire Velocity Transmitters

Velocity / Flow Sensor Class C310• Usesmultifunctionsensorsinmode

velocityorflow• Outputs:2forinterchangeableprobes• One(1)slotforinterchangeablecardSPI-2• Simultaneousdisplayof1to4parameters• Directionpointer• Four(4)visual(bicolorled)andaudiblealarms• Analogoutputs:2(4wires)0/5-10Vor0/4-20mA;

2additionaloutputs(option)• Four-relaycard(option)• Supply:24Vdc/Vacor115/230Vac• Outputsdiagnostic• Ethernetcommunication(option)• RS485communication,MODBUSprotocole(option)• CaseinABSwithfrontinSSIP65,

withorwithoutgraphicback-lighteddisplay• Mount:¼turnonSSwallfixationplate

SVH-14 velocity/temperatureprobe,interchangeablevaneØ14mm, 300mmlong Range from0to25m/s/from-20to+80°C(5000ft/min) Velocity 0.8to3m/s,±3%ofreading±0.1m/s,from3.1to25m/s, ±1%ofreading±0.3m/s

SVH-70 velocity/temperatureprobe,interchangeablevaneØ70mm, 200mmlong Range from-5to35m/s/from-20to+80°C/(6900ft/min) Velocity 0.4to3m/s,±3%ofreading±0.1m/s,from3.1to35m/s, ±1%ofreading±0.3m/

SVH-100 velocity/temperatureprobe,interchangeablevaneØ100mm, 200mmlong Range from-5to35m/s/from-20to+80°C/(6900ft/min) Velocity 0.3to3m/s,±3%ofreading±0.1m/s,from3.1to35m/s, ±1%ofreading±0.3m/s

SVS-100 velocity/temperatureprobe,vaneØ100mm,SShotwire, 300mmlong Range from0to30m/s/from-20to+80°C/(6000ft/min) Velocity 0to3m/s,±3%ofreading±0.03m/s,from3.1to30m/s, ±3%ofreading±0.1m/s

SVO velocityandtemperaturehotwire300mmlength,8mmdiameter Range From0to5m/s/from0to+50°C/(1000pi/min) Velocity Airvelocity:±3%ofreading±0.05m/s

Good for all models Temperature Pt100±0.4%ofreading±0.3°C Flow:±3%ofreadingor±0.03coversurface(cm2)

C310

ProbesCode SVH–14SVH–70SVH–100SVS–100SVO

Code Description C310–BO Multifunctionsensor;supply24VAC/cc,withdisplayC310–BN Multifunctionsensor;supply24VAC/cc,withoutdisplayC310–HO Multifunctionsensor;supply115/230VAC,withdisplayC310–HN Multifunctionsensor,supply115/230VAC,withoutdisplay

Page 24: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n24

Anemomaster Model 6162 de KANOMAXHigh Temperature Anemometer

Features:• Airvelocityandtemperaturemeasure-

mentsin932°F(500°C)environments• Hightemperaturemeasuringsolution

requiresModel6162withoptionalhightemperatureprobe(0203,0204or0205)

Main Unit SpecificationsDatalogging 999measurementsAnalogOutput 0to1VoltRemoteTerminal Start/StopKeyPowerSupply 6CcellBatteriesorACAdapterDimensions w8.7"xh3.3"xd5.9"Weight 4.0lbs(1.8Kg)

Probes 0203 0204 / 0205

Temp.Range

Air Velocity Measuring

Range

0-100°C 40to9840fpm(0.2to50.0m/s

100-200°C 80to9840fpm(0.4to50.0m/s

200-300°C n/a 138to9840fpm(0.7to50.0m/s

300-500°C n/a 197to9840fpm(1.0to50.0m/s

Accuracy +/–3%fullscale

Temperature Measuring

Range

32to392°F(0-200°C

32to932°F(0-500°C)

Accuracy +/–1%ofreading

Dimensions Weight

Ø11x200mmØ(0.4"x7.8")

0204Ø14x1000mm)0205Ø14x500mm

Probe Cables TeflonCoating

Heat resistance 392°F(200°C)

Extension Cable VinilCoating

Heat resistance 176°F(80°C)

Code Description 6162 Anemometer, Includesshoulderstrap, ACadapter,2pcs.analogoutputcable, and6pcs.Ccellbatteries.Withoutprobe0203 Probe0to200°C,9840ft/minwith1.5m cable,Carryingcase,5mcableextension andCertificate0204 Probe0to500°C,9840ft/minwith10m cable,Carryingcase,5mcableextension andCertificate0205 Probe0to500°C,9840ft/minwith10m cable,Carryingcase,5mcableextension andCertificate

A I R V E L o C I T Y A N D A I R F L o WKIMO digital Hygrometer / ThermometerModel HD50

• Easytousen• HOLDfunction"• Autoshut-off:20minutes• Built-inprobeComeswithadjustingcertificateandcarryingcase.

Order Code Code Description HD50 Hygro-thermomètreKIMO

Parameter Temperature Humidity

Measuring unit °C,°F %RHRange of measure de-20à+70°C de5à95%RHAccuracy ±0.4%ofreading±0.3°C ±1.8%RH(from15°Cto25°C)Resolution 0.1°C 0.1%RHResponse time T63=5s T63=4s

KIMO Digital Thermo-HygrometerHD110 Series

• Adjustablebacklight• Hold-min-maxfunctions• Selectionofunits• Relativehumidity,dewpointand

temperaturemeasurements• Selectionofunits(temperatureandDewpoint)• Adjustableandresetableautoshut-offUnitsareshippedwith:onehygrometryprobeØ13mm,lg.110mm,calibrationcertificate(exceptversionSwhichcomeswithanadjustingcertificate)andacarryingcase.

Order code Code Description HD110 Hygro-thermometerwithcalibrationcertificateandcase HD110S Hygro-thermometerwithadjustingcertificateandcase

Parameter Measuring range Accuracies Resolution Relative humidity From5to95%HR ±1.8%HR 0.1%HR (from15°Cto25°C)Point de rosée From-40to+70°Ctd/°Ftd ±0.8%ofreading 0.1°Ctd/°Ftd ±0.6°CtdTempérature From-20to+70°C/°F ±0.4%ofreading 0.1°C/°F ambiante ±0.3°C

FLUKE Hygro-ThermometerModel 971

• Temperaturemeasuringrangefrom-20°Cto60°C(-4°Fto140°F)

• Relativehumidityfrom5%to95%• Alsomeasurewetbulband

dewpointtemperatures• Holdofmin/max/avgvalues• Temperatureaccuracy0°Cto45°C±0.5°C

-20°Cto0°Cand45°Cto60°C±1.0°C,32°Fto113°F±1.0°F-4°Fto32°Fand113°Fto140°F±2.0°F

• Relativehumidityaccuracy10%to90%HRto23°C(73,4°F)±2,5%HR<10%>90%HRto23°C(73,4°F)±5,0%HR

• Responsetime(humidity):For90%oftotalrange60secondswitha1m/saircurrent

• Humiditysensor:Electroniccapacitancepolymerfilmsensor.• 99pointsmemory

Code Description 971 DigitalhygrometerCE-HRT CalibrationcertificateC23 Softcarryingcase

Page 25: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n 25

I N D E XALNOR Hot Wire Anemometers

ModelsAVM430andAVM440 - - - - - - - - - - - 19RVA501 - - - - - - - - - - - - - - - - - - - - - - - - - 19801750- - - - - - - - - - - - - - - - - - - - - - - - - - 19RVA801 - - - - - - - - - - - - - - - - - - - - - - - - - 19

ALNOR Vane AnemometerModelRVA801- - - - - - - - - - - - - - - - - - - - - 19TheRVA501- - - - - - - - - - - - - - - - - - - - - - - 19

AIRFLOW Digital BarometersModelDB3- - - - - - - - - - - - - - - - - - - - - - - - 11

ALNOR ANALOG BALOMETERModelABT701- - - - - - - - - - - - - - - - - - - - - 20

ALNOR Digital Balometer - MicromanometerModelEBT731 - - - - - - - - - - - - - - - - - - - - - 20AccessoriesforABT701andEB731- - - - - - - 20

ALNOR Digital MicromanometerModelEBT730 - - - - - - - - - - - - - - - - - - - - - 13EBT - - - - - - - - - - - - - - - - - - - - - - - - - - - - 138934 - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

ALNOR Digital MicromanometersAXD620- - - - - - - - - - - - - - - - - - - - - - - - - 13

Anemomaster Model 6162 de KANOMAXHighTemperatureAnemometer - - - - - - - - - - 22Features: - - - - - - - - - - - - - - - - - - - - - - - - - 22

BADOTHERM Repairable (BDT) GaugesBDT183(SS)Series - - - - - - - - - - - - - - - - - -3

BASCO Pressure GaugesBP750Series - - - - - - - - - - - - - - - - - - - - - - -2

BASCO Low Pressure GaugesBP9Series- - - - - - - - - - - - - - - - - - - - - - - - -5

BASCO Pressure GaugesKVSeries - - - - - - - - - - - - - - - - - - - - - - - - -1

BASCO Pressure Gauges760Series - - - - - - - - - - - - - - - - - - - - - - - - -1KP740Series - - - - - - - - - - - - - - - - - - - - - - -1

Accessories for Series KV, KP and 760 - - - - - - - - - - - - - - 1

BETA Digital GaugeModelBetaGaugeP.I.- - - - - - - - - - - - - - - - - -6BETAHighAccuracyDigitalGaugeModelPiR- - - - - - - - - - - - - - - - - - - - - - - - -6BETA/MARTELCalibratorwithElectricPumpModelBetaGauge330 - - - - - - - - - - - - - - - - 15

BETA/MARTEL Digital Calibrator ManometersSeries301,311A,321A - - - - - - - - - - - - - - - 15ModelBetaGauge301 - - - - - - - - - - - - - - - - 15ModelBetaGauge311A - - - - - - - - - - - - - - - 15ModelBetaGauge321A - - - - - - - - - - - - - - - 15BETAPneumaticandHydraulicManualPumpsSeriesMECP - - - - - - - - - - - - - - - - - - - - - - 14

BETA Pressure CalibratorModelT-140 - - - - - - - - - - - - - - - - - - - - - - 14

BETA Pressure ModulesForBetagauge325,DMC1410,MC1210,MC1010,BG321,BG311,BG301,BG330 - - - 14

Bronze ValvesDickson Pressure Recorders

PW8Series - - - - - - - - - - - - - - - - - - - - - - - -4DWYER Differential Gauges

Magnehelic®2000Series - - - - - - - - - - - - - -8DWYER Differential Pressure Sensors

MS,Magnesense®Series - - - - - - - - - - - - - -8DWYER Differential Pressure Switch

Series1900 - - - - - - - - - - - - - - - - - - - - - - - -8DWYER Differential Pressure Switch

Photohelic®A3000Series - - - - - - - - - - - - - -8DWYER Digital Gauges

DPG-100Series - - - - - - - - - - - - - - - - - - - - -6DPG-000Series - - - - - - - - - - - - - - - - - - - - -6

DWYER Economical Level SwitchesSeriesF7- - - - - - - - - - - - - - - - - - - - - - - - - -7

DWYER Inclined Column ManometerModel25-MarkII- - - - - - - - - - - - - - - - - - - -8

DWYER Inclined Column ManometerModel400-10 - - - - - - - - - - - - - - - - - - - - - -8DWYERPitotTubesSeries160 - - - - - - - - - - - - - - - - - - - - - - - - 11

DWYER Vertical Column Gauges1211Series - - - - - - - - - - - - - - - - - - - - - - - -8DwyerWet/WetHandheldDigitalManometerSérie490 - - - - - - - - - - - - - - - - - - - - - - - - 14

ENFM Pressure GaugesSeries6211 - - - - - - - - - - - - - - - - - - - - - - - -4

ENFM Welded Diaphragm SealsEconomical05Series - - - - - - - - - - - - - - - - -5

Explosion-proof Differential Pressure TransmitterMercoidSeries3100D- - - - - - - - - - - - - - - - -7Explosion-ProofPressureTransmitterMercoidSeries3200G- - - - - - - - - - - - - - - - -7

FLOTECT® Flow Mini-Size SwitchModelsV10&V11(DWYER)- - - - - - - - - - - - -7

FLOTECT® Level SwitchSeriesL4(DWYER)- - - - - - - - - - - - - - - - - - -7

FLOTECT® Level SwitchModelL8(DWYER)- - - - - - - - - - - - - - - - - - -7

FLUKE Digital MicromanometerModel922 - - - - - - - - - - - - - - - - - - - - - - - - 13

FLUKE Hygro-ThermometerModel971 - - - - - - - - - - - - - - - - - - - - - - - - 22

HYETT Robust Membrane SealsSeries42M/42M01- - - - - - - - - - - - - - - - - - -2

HYETT Welded Diaphragm Seals15AWand25AWSeries- - - - - - - - - - - - - - - -5

KIMO AMI 300 KITSHE100 - - - - - - - - - - - - - - - - - - - - - - - - - - 17HE70 - - - - - - - - - - - - - - - - - - - - - - - - - - - 17HET14 - - - - - - - - - - - - - - - - - - - - - - - - - - 17SDFG - - - - - - - - - - - - - - - - - - - - - - - - - - - 17FC300- - - - - - - - - - - - - - - - - - - - - - - - - - - 17FCT900- - - - - - - - - - - - - - - - - - - - - - - - - - 17RD300 - - - - - - - - - - - - - - - - - - - - - - - - - - 17SCOTetSCO2T - - - - - - - - - - - - - - - - - - - - 17SFCO - - - - - - - - - - - - - - - - - - - - - - - - - - - 17HR110 - - - - - - - - - - - - - - - - - - - - - - - - - - 17HRI300 - - - - - - - - - - - - - - - - - - - - - - - - - - 17HRI300RF- - - - - - - - - - - - - - - - - - - - - - - - 17ETC - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17RTS- - - - - - - - - - - - - - - - - - - - - - - - - - - - 17SCO2TH - - - - - - - - - - - - - - - - - - - - - - - - - 17TOP- - - - - - - - - - - - - - - - - - - - - - - - - - - - 17SVTH - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

KIMO Compact Vane Thermo-AnemometerModelLV50- - - - - - - - - - - - - - - - - - - - - - - 18

KIMO Differential Pressure and Temperature Sensors / Transmitters

Sensors/TransmittersClass210–CP210- - - -9KIMO Differential Pressure Sensors / Transmitters

Sensor/TransmitterClass110–CP111-CP112-CP113 - - - - - - - - - - - - - - - - - - - - -9Sensor/TransmitterClassCP114-CP115 - - - -9KIMODifferentialPressureSwitchPST- - - - - - -9

KIMO Digital BarometerModelMP55 - - - - - - - - - - - - - - - - - - - - - - 11

KIMO Digital FlowmeterModelDBM610- - - - - - - - - - - - - - - - - - - - - 20FUNCTIONS- - - - - - - - - - - - - - - - - - - - - - - 20KIMOdigitalHygrometer/ThermometerModelHD50- - - - - - - - - - - - - - - - - - - - - - - 22KIMODigitalMicromanometersSeriesMP200- - - - - - - - - - - - - - - - - - - - - - 12

KIMO Digital MicromanometersSeriesMP50andMP51 - - - - - - - - - - - - - - - 12

KIMO Digital MicromanometersMP110Series- - - - - - - - - - - - - - - - - - - - - - 12

KIMO Digital Thermo-HygrometerHD110Series - - - - - - - - - - - - - - - - - - - - - - 22

KIMO Flush-mount multifunction pressure transmitterCPE310-S- - - - - - - - - - - - - - - - - - - - - - - - 13

KIMO Hot Wire Thermo-anemometerModelVT110- - - - - - - - - - - - - - - - - - - - - - 19Accessories - - - - - - - - - - - - - - - - - - - - - - - 19ModelVT200- - - - - - - - - - - - - - - - - - - - - - 19AccessoriesforClass50and110Instruments- 19

KIMO Hot Wire Thermo-AnemometerModelVT50 - - - - - - - - - - - - - - - - - - - - - - - 18

KIMO Hot Wire Velocity TransmittersSensors-transmitters,ClassCTV110 - - - - - - 21Velocity/FlowSensorClassC310- - - - - - - - 21Sensors-transmittersClassCTV210 - - - - - - - 21

KIMO Inclined Column ManometersSeriesHPandTX - - - - - - - - - - - - - - - - - - - 10

KIMO INTERCHANGEABLE MODULESForportablesClass200and300- - - - - - - - - 16KIMOMeasuringProbesForportablesClasses200-300 - - - - - - - - - 17KIMOMesuringBladesDEBIMO

KIMO Multifunction AnemometersModelsAMI300/301 - - - - - - - - - - - - - - - - - 16

KIMO Pitot TubesSeriesTPL-TwithThermocouple - - - - - - - - - 11

KIMO Portable Liquid Column ManometersSeriesMTandKM45 - - - - - - - - - - - - - - - - - 10

KIMO Sensor / Transmitter for atmospheric pressureCP116 - - - - - - - - - - - - - - - - - - - - - - - - - - -9

KIMO Vane Thermo-AnemometerModelLV130 - - - - - - - - - - - - - - - - - - - - - - 18

KIMO Vane Thermo-AnemometersModelsLV111–LV117–LV110 - - - - - - - - - 18

KIMO Vertical Column ManometersTJandLUSeries- - - - - - - - - - - - - - - - - - - - 10Velocity/FlowSensorClassC310- - - - - - - - 10

LUFFT Digital BarometerModelC300 - - - - - - - - - - - - - - - - - - - - - - - 11

Martel Portable High pressure Pneumatic Hand Pump MECP2000 - - - - - - - - - - - - - - - - - - - - - - - 14

MAXIMUM Analog Barometers

Micro-manomètre avec mesure de la vitesse d'airModèleMP120 - - - - - - - - - - - - - - - - - - - - - 12

MILJOCO GaugesP4598LSeries - - - - - - - - - - - - - - - - - - - - - -2

NOSHOK Pressure Transducers100Series - - - - - - - - - - - - - - - - - - - - - - - - -6200Series - - - - - - - - - - - - - - - - - - - - - - - - -6

PERMA-CAL Direct Drive Test GaugesTESTSeries(101T) - - - - - - - - - - - - - - - - - - -5

Snubbers (Adjustable)PressurePistonSnubbersTypeLongOrifice - - -2PressurePistonSnubbersTypeShortOrifice- -2SinteredPressureSnubbers- - - - - - - - - - - - - -2Siphons- - - - - - - - - - - - - - - - - - - - - - - - - - -2SISCOP/TPlugs - - - - - - - - - - - - - - - - - - - - -2P/TPlugs - - - - - - - - - - - - - - - - - - - - - - - - -2

TSI Hydronic ManometersSeriesHM- - - - - - - - - - - - - - - - - - - - - - - - 11

WEKSLER Digital GaugesTypeWDG4251L- - - - - - - - - - - - - - - - - - - - -5

WEKSLER Process GaugesAA442Series - - - - - - - - - - - - - - - - - - - - - - -4PW4Series - - - - - - - - - - - - - - - - - - - - - - - -4

Page 26: PRESSURE - Chevrier Instruments...2016 Version 1 PRESSURE BASCO Pressure Gauges KV Series • Dry, accuracy Grade B (3-2-3) • SS Case, brass fitting, glass lens • SS chromed bezel

w w w. c h e v r i e r i n s t r u m e n t s . c o m2 0 1 6 Ve r s i o n26

S A L E S C O N D I T I O N S • C r E D I T • A C C O U N T S • S H I P P I N G

15AW and 25AW Series - - - - - - - - - - - - - - - - - - - - - - - - 5

100 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

200 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

760 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1

1211 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

8934 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

801750 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

AA442 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4

Accessories- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

Accessories for ABT701 and EB731- - - - - - - - - - - - - - - - 20

AXD 620 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

BDT183 (SS) Series - - - - - - - - - - - - - - - - - - - - - - - - - - - 3

BP9 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5

BP750 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2

CP116 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9

CPE 310-S- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

DPG-000 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

DPG-100 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

EBT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

Economical 05 Series - - - - - - - - - - - - - - - - - - - - - - - - - - 5

ETC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

FC300- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

FCT900- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

Features:- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22

For Betagauge 325, DMC1410, MC1210, MC1010, BG321, BG311, BG301, BG330 - - - - - - - - - - - - - - - - - - - 14

For portables Class 200 and 300 - - - - - - - - - - - - - - - - - 16

For portables Classes 200 - 300 - - - - - - - - - - - - - - - - - - 17

FUNCTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20

HD110 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22

HE70 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

HE100 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

HET14- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

High Temperature Anemometer- - - - - - - - - - - - - - - - - - - 22

HR110 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

HRI300 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

HRI300RF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

P/T Plugs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2

KP740 Series- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1

KV Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1

Magnehelic® 2000 Series - - - - - - - - - - - - - - - - - - - - - - - 8

MECP2000 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14

Mercoid Series 3100D- - - - - - - - - - - - - - - - - - - - - - - - - - 7

Mercoid Series 3200G- - - - - - - - - - - - - - - - - - - - - - - - - - 7

Model 25 - Mark II - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

Model 400-10 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

Model 922- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

Model 971- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22

Model ABT701 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20

Model BetaGauge 301 - - - - - - - - - - - - - - - - - - - - - - - - - 15

Model BetaGauge 311A - - - - - - - - - - - - - - - - - - - - - - - - 15

Model BetaGauge 321A - - - - - - - - - - - - - - - - - - - - - - - - 15

Model BetaGauge 330 - - - - - - - - - - - - - - - - - - - - - - - - - 15

Model BetaGauge P.I. - - - - - - - - - - - - - - - - - - - - - - - - - - 6

Model C300- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Model DB3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Model DBM610 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20

Model EBT730 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13

Model EBT731 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20

Modèle MP120- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12

Model HD50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 22

Model L8 (DWYER)- - - - - - - - - - - - - - - - - - - - - - - - - - - - 7

Model LV50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18

Model LV130 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18

Model MP55 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Model PiR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

Model RVA801 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

Models AMI 300/301- - - - - - - - - - - - - - - - - - - - - - - - - - 16

Models AVM430 and AVM440 - - - - - - - - - - - - - - - - - - - 19

Models LV111 – LV117 – LV110 - - - - - - - - - - - - - - - - - - 18

Models V10 & V11 (DWYER) - - - - - - - - - - - - - - - - - - - 7

Model T-140 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14

Model VT50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 18

Model VT110 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

Model VT200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

MP110 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12

MS, Magnesense® Series - - - - - - - - - - - - - - - - - - - - - - - 8

P4598L Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2

Photohelic® A3000 Series- - - - - - - - - - - - - - - - - - - - - - - 8

PST - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9

PW4 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4

PW8 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4

RD300 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

RTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

RVA501 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

RVA801 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

SCO2TH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

SCOT et SCO2T - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

SDFG - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

Sensors / Transmitters Class 210 – CP210 - - - - - - - - - - - - 9

Sensors / Transmitters, Class CTV 110 - - - - - - - - - - - - - 21

Sensors / Transmitters Class CTV 210 - - - - - - - - - - - - - - 21

Sensor / Transmitter Class 110 – CP111 - CP112 - CP113 - 9

Sensor / Transmitter Class CP114 - CP115- - - - - - - - - - - - 9

Série 490 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14

Series 42M/42M01 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2

Series 160- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Series 301, 311A, 321A- - - - - - - - - - - - - - - - - - - - - - - - 15

Series 1900- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

Series 6211- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4

Series F7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7

Series HM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Series HP and TX - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10

Series L4 (DWYER) - - - - - - - - - - - - - - - - - - - - - - - - - 7

Series MECP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14

Series MP50 and MP51- - - - - - - - - - - - - - - - - - - - - - - - 12

Series MP200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12

Series MT and KM45- - - - - - - - - - - - - - - - - - - - - - - - - - 10

Series TPL-T with Thermocouple- - - - - - - - - - - - - - - - - - 11

SFCO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

SVTH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

TEST Series (101T)- - - - - - - - - - - - - - - - - - - - - - - - - - - - 5

The RVA501- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 19

TJ and LU Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10

TOP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

Type WDG4251L- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5

Velocity / Flow Sensor Class C310 - - - - - - - - - - - - - - - - 10

Velocity / Flow Sensor Class C310 - - - - - - - - - - - - - - - - 21

I N D E X B Y m o D E L

OrdersWhenordering,useasoftenaspossiblethecodeorreferencenumberoftherequiredinstrument.Ifavailable,alsomentionmanu-facturer'sname,instrumentsizes,buildingmaterial,etc.Thishelpsusinservingyoufaster and avoiding mistakes.

It is possible to obtain certain discounts orspecialpricesforlargequantityorders.Please contact us.

AllpricesareFOBMontreal-Northandappli-cabletaxesareextra.

Allpricesaresubjecttochangewithoutnotice.

Incomplete OrderWhenshippinganorder,anyitemnotinstockisnotedonthepackingslipandputin

backorder;thismerchandiseislatersentondeferreddelivery.

Shouldtheremainingmerchandisebecan-celled,pleaseadviseoursalesrepresentativeas soon as possible.

Payment conditionsUnlessyouhaveanopenaccountwithus,allshipmentsaremadeC.O.D.

Paymenttermsare:2%ifpaidwithin10daysORnet30days.

PurchasescanalsobepaidbyVisa,MasterCard,AmericanExpressorInterac.

Wereservetherighttodelayadeliverytoanyclientwhoseaccountisoverdue.

New accountsCompanieswhowishtoopenanaccountwithusmustprovidewithbankandcommer-cialreferences.Forsuch,askforour"CreditRequestForm".Resultsofourinquiryarecommunicated as soon as possible.

ShippingIfinstock,merchandiseisusuallyshippedthenextday.

Shippingconditions:yourtransportcompany,atyourexpense;otherwise$10.50ofprepaidcostisaddedtoyourinvoice.