Prodigy r PLC Gateway Generation III Customer Product Manual Part 1102107-02 Issued 12/14 NORDSON CORPORATION AMHERST, OHIO USA For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319. This document is subject to change without notice. Check http://emanuals.nordson.com for the latest version.

Upload: others

Post on 06-Nov-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC GatewayGeneration III

Customer Product ManualPart 1102107-02

Issued 12/14

NORDSON CORPORATION AMHERST, OHIO USA

For parts and technical support, call the Finishing Customer Support Center at (800) 433-9319.

This document is subject to change without notice.Check http://emanuals.nordson.com for the latest version.

Page 2: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Part 1102107-02 � 2014 Nordson Corporation

Contact UsNordson Corporation welcomes requests for information, comments, andinquiries about its products. General information about Nordson can befound on the Internet using the following address:http://www.nordson.com.Address all correspondence to:

Nordson CorporationAttn: Customer Service555 Jackson StreetAmherst, OH 44001

NoticeThis is a Nordson Corporation publication which is protected by copyright.Original copyright date 2007. No part of this document may bephotocopied, reproduced, or translated to another language without theprior written consent of Nordson Corporation. The information containedin this publication is subject to change without notice.

Trademarks

Prodigy, HDLV, Color-on-Demand, Nordson, and the Nordson logo areregistered trademarks of Nordson Corporation.

All other trademarks are the property of their respective owners.

Page 3: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Change Record i

Part 1102107-02� 2014 Nordson Corporation

tents

Change Record

Revision Date Change

1102107A 07/10 Manual part number 1102107 replaces 1077102.

1101422 replaces 1076798 for Prodigy PLC Gateway.

1101454 replaces 1083689 for Prodigy PLC Gateway PCA Kit.

Added pattern air range, gun purge, and pump speed settings.

02 12/14 Updated drawings and notes

Page 4: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Change Recordii

Part 1102107-02 � 2014 Nordson Corporation

Page 5: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Table of Contents iii

Part 1102107-02� 2014 Nordson Corporation

Table of ContentsSafety 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Qualified Personnel 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intended Use 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Regulations and Approvals 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Personal Safety 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fire Safety 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Grounding 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Action in the Event of a Malfunction 3. . . . . . . . . . . . . . . . . . . . .Disposal 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operation Modes 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Preset Mode 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Analog Mode 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Enclosure Mounting 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Electrical Power and Fusing 7. . . . . . . . . . . . . . . . . . . . . . . . . . . .Gateway Circuit Board Jumper and Switch Settings 7. . . . . . . .Preset Mode Connections and Settings 9. . . . . . . . . . . . . . . . . . .

Gateway Connections and Settings 9. . . . . . . . . . . . . . . . . . .Analog Mode Connections and Settings 10. . . . . . . . . . . . . . . . . .

Gateway Connections and Settings 10. . . . . . . . . . . . . . . . . . .Electrostatics 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gateway Wiring and Setting Diagram − Preset Mode 12. . . . . .Gateway Wiring and Setting Diagram − Analog Mode 13. . . . . .Pump Control Board Connections and Settings 14. . . . . . . . . . .Gun Cables 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Prodigy MGI Settings 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operation 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power On 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Triggering 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Gun Strobe 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Faults 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Parts 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Gateway Replacement Parts 18. . . . . . . . . . . . . . . . . . . . . . . . . . .Gun Cables 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Optional Enclosure Mounting Kit 19. . . . . . . . . . . . . . . . . . . . . . . .

Enclosure Wiring Diagram 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Table of Contentsiv

Part 1102107-02 � 2014 Nordson Corporation

Page 7: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 1

Part 1102107-02� 2014 Nordson Corporation

Prodigy� PLC Gateway

Safety Read and follow these safety instructions. Task- and equipment-specificwarnings, cautions, and instructions are included in equipmentdocumentation where appropriate.

Make sure all equipment documentation, including these instructions, isaccessible to all persons operating or servicing equipment.

Qualified Personnel Equipment owners are responsible for making sure that Nordson equipmentis installed, operated, and serviced by qualified personnel. Qualifiedpersonnel are those employees or contractors who are trained to safelyperform their assigned tasks. They are familiar with all relevant safety rulesand regulations and are physically capable of performing their assignedtasks.

Intended Use Use of Nordson equipment in ways other than those described in thedocumentation supplied with the equipment may result in injury to personsor damage to property.

Some examples of unintended use of equipment include

� using incompatible materials

� making unauthorized modifications

� removing or bypassing safety guards or interlocks

� using incompatible or damaged parts

� using unapproved auxiliary equipment

� operating equipment in excess of maximum ratings

Regulations and Approvals Make sure all equipment is rated and approved for the environment in whichit is used. Any approvals obtained for Nordson equipment will be voided ifinstructions for installation, operation, and service are not followed.

All phases of equipment installation must comply with all federal, state, andlocal codes.

Page 8: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway2

Part 1102107-02 � 2014 Nordson Corporation

Personal Safety To prevent injury follow these instructions.

� Do not operate or service equipment unless you are qualified.

� Do not operate equipment unless safety guards, doors, or covers areintact and automatic interlocks are operating properly. Do not bypass ordisarm any safety devices.

� Keep clear of moving equipment. Before adjusting or servicing anymoving equipment, shut off the power supply and wait until theequipment comes to a complete stop. Lock out power and secure theequipment to prevent unexpected movement.

� Relieve (bleed off) hydraulic and pneumatic pressure before adjusting orservicing pressurized systems or components. Disconnect, lock out,and tag switches before servicing electrical equipment.

� Obtain and read Material Safety Data Sheets (MSDS) for all materialsused. Follow the manufacturer’s instructions for safe handling and useof materials, and use recommended personal protection devices.

� To prevent injury, be aware of less-obvious dangers in the workplacethat often cannot be completely eliminated, such as hot surfaces, sharpedges, energized electrical circuits, and moving parts that cannot beenclosed or otherwise guarded for practical reasons.

Fire Safety To avoid a fire or explosion, follow these instructions.

� Do not smoke, weld, grind, or use open flames where flammablematerials are being used or stored.

� Provide adequate ventilation to prevent dangerous concentrations ofvolatile materials or vapors. Refer to local codes or your material MSDSfor guidance.

� Do not disconnect live electrical circuits while working with flammablematerials. Shut off power at a disconnect switch first to preventsparking.

� Know where emergency stop buttons, shutoff valves, and fireextinguishers are located. If a fire starts in a spray booth, immediatelyshut off the spray system and exhaust fans.

� Clean, maintain, test, and repair equipment according to the instructionsin your equipment documentation.

� Use only replacement parts that are designed for use with originalequipment. Contact your Nordson representative for parts informationand advice.

Page 9: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 3

Part 1102107-02� 2014 Nordson Corporation

Grounding

WARNING: Operating faulty electrostatic equipment is hazardous and cancause electrocution, fire, or explosion. Make resistance checks part of yourperiodic maintenance program. If you receive even a slight electrical shockor notice static sparking or arcing, shut down all electrical or electrostaticequipment immediately. Do not restart the equipment until the problem hasbeen identified and corrected.

Grounding inside and around the booth openings must comply with NFPArequirements for Class II Division 1 or 2 Hazardous Locations. Refer toNFPA 33, NFPA 70 (NEC articles 500, 502, and 516), and NFPA 77, latestconditions.

� All electrically conductive objects in the spray areas shall be electricallyconnected to ground with a resistance of not more than 1 megohm asmeasured with an instrument that applies at least 500 volts to the circuitbeing evaluated.

� Equipment to be grounded includes, but is not limited to, the floor of thespray area, operator platforms, hoppers, photoeye supports, andblow-off nozzles. Personnel working in the spray area must begrounded.

� There is a possible ignition potential from the charged human body.Personnel standing on a painted surface, such as an operator platform,or wearing non-conductive shoes, are not grounded. Personnel mustwear shoes with conductive soles or use a ground strap to maintain aconnection to ground when working with or around electrostaticequipment.

� Operators must maintain skin-to-handle contact between their hand andthe gun handle to prevent shocks while operating manual electrostaticspray guns. If gloves must be worn, cut away the palm or fingers, wearelectrically conductive gloves, or wear a grounding strap connected tothe gun handle or other true earth ground.

� Shut off electrostatic power supplies and ground gun electrodes beforemaking adjustments or cleaning powder spray guns.

� Connect all disconnected equipment, ground cables, and wires afterservicing equipment.

Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the systemimmediately and perform the following steps:

� Disconnect and lock out electrical power. Close pneumatic shutoffvalves and relieve pressures.

� Identify the reason for the malfunction and correct it before restarting theequipment.

Disposal Dispose of equipment and materials used in operation and servicingaccording to local codes.

Page 10: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway4

Part 1102107-02 � 2014 Nordson Corporation

Description The Prodigy� PLC Gateway is the interface between an external controllerand a Prodigy HDLV� pump panel and MGI (Manual Gun Interface). TheProdigy MGI software must be version 2.2 or later. The software allows theMGI to control and trigger a Prodigy automatic powder spray gun and HDLVpump in response to commands from the external controller.

The Gateway is capable of interfacing with two Prodigy MGIs and twoautomatic guns, through the Prodigy Manual System pump panel or theProdigy Manual Color-on-Demand� System pump panel. The Gatewayconverts digital or analog signals from an external controller into ProdigyCAN messages.

Robot Controller or PLCProdigy Spray Gun

InterfaceWiring

Prodigy PLC GatewayEnclosure

AC Power

AC Power

CAN NetworkCable

CAN Network/Power Cable

8−meter Gun Cable(4 meter Extensionavailable)

Prodigy MGI #1w/GatewaySoftware

Prodigy Pump Panel

CAN Network/Power Cable

to MGI #2(if used)

Robot InterfaceSignals

Analog and/orDigital

Figure 1 Typical System Diagram

Page 11: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 5

Part 1102107-02� 2014 Nordson Corporation

Operation Modes

Preset Mode Preset mode is used to switch between presets, which are sets ofpre-programmed spray parameters. Up to 10 presets can be programmedand stored in the MGI.

Preset Mode operates as follows:

1. The external controller first sends a digital signal corresponding to thedesired preset number (1−10) to the Gateway.

2. When it is time to switch to the new preset, the external controller sendsthe Gateway a gun strobe signal.

3. The Gateway reads the preset number signal, converts it into a CANmessage and sends it to the Prodigy MGI.

4. The MGI now operates the spray gun and pump using the parameters ofthe new preset.

Analog Mode Analog mode is used for direct control of the spray parameters for Preset 1.In analog mode, the external controller sends signals to the Gateway tocontrol:

� Powder flow (0−10 Vdc)

� Pattern air flow (0−10 Vdc)

� Assist air compensation (4−20 mA)

� Electrostatics (0−10 Vdc)

In analog mode, the MGI uses only Preset 1 to control the spray gun andpump. The spray parameters for Preset 1 are changed as needed by theexternal controller.

Analog mode operates as follows:

1. The external controller sends the desired analog signals to the Gateway.

2. When the signals are stable the external controller sends the Gateway agun strobe signal.

3. The Gateway then reads the analog signals at its inputs, converts theminto CAN messages, and sends them to the MGI.

4. The MGI changes the spray parameters for preset 1. The gun andpump now operate with the new parameters.

Page 12: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway6

Part 1102107-02 � 2014 Nordson Corporation

Installation WARNING: Allow only qualified personnel to perform the following tasks.Follow the safety instructions in this document and all other relateddocumentation.

WARNING: Use dust-tight conduit connectors or strain reliefs to routecables into all electrical enclosures. Installation must be done according tocode and care must be taken to maintain the dust-tight integrity of theenclosures.

Enclosure Mounting If mounting the enclosure on a Prodigy Manual System stand use theoptional mounting kit listed on page 19, and drill holes in the stand for themounting kit brackets and fasteners as shown in Figure 2.

If mounting on a wall or panel, use the dimensions shown for the enclosurefeet. Use M8 fasteners as needed.

445 mm(17.5 in.)

368.3 mm14.50 in.

470 mm18.50 in.

470 mm18.50 in.

445 mm(17.5 in.)

2

1

345

3456

Figure 2 Gateway Circuit Board Jumper Settings

1. Mounting kit brackets2. Screws, M8 x 16

3. Lock washers, M84. Flat washers, M8

5. Lock nuts, M86. Screws, M8 x 60

Page 13: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 7

Part 1102107-02� 2014 Nordson Corporation

Electrical Power and Fusing Refer to the Gateway enclosure wiring diagram on page 20.

The Gateway requires 85−230 Vac, 50−60 Hz, single phase, 21 Va inputpower.

Route the AC power leads through a knockout in the bottom of theenclosure and connect them to the L1, L2 and GND terminals on theterminal block as shown in the following wiring diagrams.

Use a liquid-tight cord grip or conduit connector in the knockout. Theenclosure must be dust-tight.

Gateway Circuit Board Jumper and Switch SettingsSee Figure 3.

Open the Prodigy PLC Gateway enclosure, locate JP11, 12, and 13 on theright side of the circuit board and make the following jumper settings foryour application:

JP11 − Mode of Operation

Preset Mode: Open (no jumper) (factory setting)Analog Mode: Jump Pins 1 and 2

JP12 − Number of Guns

1 Gun: Open (no jumper) (factory setting)2 Guns: Jump Pins 1 and 2

JP13 − Type of System

Standard Manual Gun System: Open (no jumper) (factory setting)Color-on-Demand System: Jump Pins 1 and 2

NOTE: Replacement circuit boards are jumpered and programmed at thefactory for the Prodigy PLC Gateway application. The following diagramshows the default jumper settings for the board. Only jumpers JP11, JP12,and JP13 should be changed to configure the board for the application.

SW4-4 − Pattern Air Range

Open: 0.20−2.0 SCFM (0.34−3.4 SCMH)Closed: 0.20−4.0 SCFM (0.34−6.8 SCMH) (Requires 4.0 SCFM orifice.)

Connectors P4 and P6

P4 and P6 each consist of 18 terminals that are divided into 2 sections, Aand B. Section A is a 12 position terminal and section B is a 6 positionterminal. See Figure 3.

Example: P4−13 is marked as P4B−1 on the gateway power control board(PCB).

Page 14: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway8

Part 1102107-02 � 2014 Nordson Corporation

Gateway Circuit Board Jumper and Switch Settings (contd)

1

1

1

1

1 1 1 1

1 1

1 Gun

JP6

JP7

JP8

JP9

JP11

JP12

JP13

JP14

Preset Mode

JP3 JP2

JP4

JP5

JP10

JP19

JP18 JP17 JP16 JP15

1

1

1

1

1

1

1

1

No Jumper Jumpered

CHANGE ONLY JP11, JP12, AND JP13FOR YOUR APPLICATIONLEAVE ALL OTHER JUMPERS AT FACTORY SETTINGS

NOTE:

DefaultApplication−Specific

SettingsStandard

Analog Mode

COD

1

1

1

2 Gun

JP11

JP12

JP13

OptionalApplication-Specific

Settings

1

JP1

P4 (18−1)

P6 (18−1)

Figure 3 Gateway Circuit Board Jumper Settings

Page 15: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 9

Part 1102107-02� 2014 Nordson Corporation

Preset Mode Connections and Settings

Gateway Connections and Settings Refer to Table 1 and Figure 4 to make input and output connections to theGateway circuit board. Gun 1 and 2 Alarm are optional connections.

Refer to Table 2 when programming the external controller to select presetnumbers.

See note on page 7.

Table 1 Preset Mode External Interface Connections

Signal Conn. Pins Gateway External Signal Type

Trigger 1 P6 1, 2 Input Output Dry Contacts

Trigger 2 P6 3, 4 Input Output Dry Contacts

Preset Bit 1 P5 1 Input Output Dry Contacts

Preset Bit 2 P5 2 Input Output Dry Contacts

Preset Bit 3 P5 3 Input Output Dry Contacts

Preset Bit 4 P5 4 Input Output Dry Contacts

Gun 1 Strobe P5 5 Input Output Dry Contacts

Gun 2 Strobe P5 6 Input Output Dry Contacts

Gun 1 Purge P6 9, 11 Input Output Dry Contacts

Gun 2 Purge P6 12, 14 Input Output Dry Contacts

Gun 1 Alarm P8 1, 2 Output Input 24 Vdc 250 mA Sinking

Gun 2 Alarm P8 4, 5 Output Input 24 Vdc 250 mA Sinking

Table 2 Preset Mode Preset Inputs

Preset Number P5−1 P5−2 P5−3 P5−4

1 1 0 0 0

2 0 1 0 0

3 1 1 0 0

4 0 0 1 0

5 1 0 1 0

6 0 1 1 0

7 1 1 1 0

8 0 0 0 1

9 1 0 0 1

10 0 1 0 1

1 = Shorted0 = OpenAll P5 references to common.

Page 16: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway10

Part 1102107-02 � 2014 Nordson Corporation

Analog Mode Connections and Settings

Gateway Connections and Settings Refer to Table 3 and Figure 5 to make input and output connections to theGateway circuit board. Gun 1 and 2 Alarm are optional connections.

Refer to Tables 4 and 5 when programming the external controller to setspray parameters.

See note on page 7.

Table 3 Analog Mode Inputs and Outputs

Signal Conn. Pins Gateway Robot Signal Type

Trigger 1 P6 1, 2 Input Output Dry Contacts

Trigger 2 P6 3, 4 Input Output Dry Contacts

AFC Mode P6 6, 7 Input Output Dry Contacts

Select Charge Bit 1 P5 1 Input Output Dry Contacts

Select Charge Bit 2 P5 2 Input Output Dry Contacts

Select Charge Bit 3 P5 3 Input Output Dry Contacts

Gun 1 Strobe P5 5 Input Output Dry Contacts

Gun 2 Strobe P5 6 Input Output Dry Contacts

Gun 1 Purge P6 9, 11 Input Output Dry Contacts

Gun 2 Purge P6 12, 14 Input Output Dry Contacts

Gun 1 Alarm P8 1, 2 Output Input 24 Vdc 250 mA Sinking

Gun 2 Alarm P8 4, 5 Output Input 24 Vdc 250 mA Sinking

Pump 1 Speed P5 7 Input Output Dry Contacts

Pump 2 Speed P5 8 Input Output Dry Contacts

Table 4 Analog Mode Spray Parameter Signals

Parameter Conn. Pins Low Scale

kV P4 9, 10 (common) 0−1 V = 0 kV 1−10 V = 25−95 kV

A (AFC) P4 11, 12 (common) 0−1 V = 10 A 1−10 V = 10−100 A

Powder Flow P4 13, 14 (common) − 0−10 V = 0−100%

Pattern Air Flow P4 15, 16 (common) 0−1 V = 0.2 SCFM 1−10V = 0.2−2.0 SCFM

Assist Air Compensation P4 8, 7 (common) 0−3.9mA = 0% 4−20 mA = −50% to +50%

SW4-4 − Pattern Air Range

Open: 0.20−2.0 SCFM (0.34−3.4 SCMH)Closed: 0.20−4.0 SCFM (0.34−6.8 SCMH) (Requires 4.0 SCFM orifice.)

Page 17: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 11

Part 1102107-02� 2014 Nordson Corporation

Electrostatics Only one electrostatic charging mode can be used at a time: kV mode, Amode (AFC mode), or pre-programmed Select Charge mode.

Refer to the Prodigy Manual Gun Controller manual (P/N1054580) forinformation on electrostatic settings.

kV Mode: This mode is the default mode. kV output is controlled byapplying 1−10 Vdc to connector P4 pins 9 and 10.

AFC Mode: This mode controls current draw (A) instead of kV output. Toplace the MGI in AFC mode, connector P6 pins 6 and 7 must be shorted.Applying 1−10 Vdc to connector P4 pins 11 and 12 then sets the currentdraw limit.

Select Charge Mode: This mode consists of 4 pre-programmedelectrostatic settings. To set a Select Charge mode, place the MGI in AFCmode, then send signals to select the mode according to Table 5.

Table 5 Select Charge Mode Signals

Coating Mode P5−1 P5−2 P5−3

1 − Recoat 1 0 0

2 − Special 0 1 0

3 − Deep Cavity 1 1 0

4 − User Programmable 0 0 1

1 = Shorted0 = OpenAll P5 references to common (P5 pins 9 to 12).

Page 18: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway12

Part 1102107-02 � 2014 Nordson Corporation

Gateway Wiring and Setting Diagram − Preset Mode

P8

123456

1 2 3

P5

123456789101112

P6

123456789101112131415161718

123

P3

123

Drain

Alarm Gun 2

Gun Strobe 1

Trigger Gun 2

Preset Bit 1Preset Bit 2

Gun Strobe 2

Drain

Preset Bit 4Preset Bit 3

Trigger Gun 1

Alarm Gun 1

Optional

GNDL1 L2

Use at least 22 AWGshielded 300Vmulticonductor cable

External Controller Prodigy PLC Gateway

Use 24 AWG TwistedPair with Shield 2conductor300 volt ratingBelden 9841Maximum Length 100M

Main PowerInput TB

For specific wiring details referto controller documentation.

OP

EN

4

3

2

1

SW3

SW1

SW2

1

P5CAN OUT W1

1

Power

Set SW1 and SW2to Position 1

Set SW3−1 to Closed to terminate CAN network,if neccesary

0

23

45678

9

1

0

23

45678

9

1 2 3

P6CAN IN

Drain

REFER TO FIGURE 6 FOR CONNECTIONSTO PUMP CONTROL BOARD, MGI, AND GUN

JUMP PINS 2 AND 3FOR ALL SYSTEM TYPES

85−230 Vac

+−

+−

Purge

Purge

Gun 1

Gun 2

White (Hi)

Blue (Low)

Whi

te

Blu

e

Whi

te

Blu

e

Note: DIP switchSW3−1 is shownhere in the Closedposition.

Figure 4 Gateway Wiring and Setting Diagram − Preset Mode

Page 19: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 13

Part 1102107-02� 2014 Nordson Corporation

Gateway Wiring and Setting Diagram − Analog Mode

P8

123456

P6

123456789101112131415161718

P3

123

P4

123456789101112131415161718

P5

123456789101112

123

+

Alarm Gun 1

Alarm Gun 2

0−10V DC

Pattern Air

+0−10V DC

Select Charge Mode Bit 2

Powder Flow

kV

Gun Strobe 2

AFC ON/OFF

Trigger Gun 2

0−10V DC

Drain

Gun Strobe 1

Drain

+

Select Charge Mode Bit 3

Select Charge Mode Bit 1

Trigger Gun 1

uA

4−20 mA

L1 L2 GND

External Controller Prodigy PLC Gateway

Use at least 22 AWGshielded 300Vmulticonductor cable

For specific wiring detailsrefer to controllerdocumentation

Main PowerInput TBOptional

SW1

SW2

Set SW1 and SW2to Position 1

Set SW3−1 to Closedto terminateCAN network,if necessary

Power

1 2 3

Drain

Use 24 AWG Twisted Pairwith Shield 2 conductor300 volt ratingBelden 9841Maximum Length 100M

P5CAN OUT

1 2 3

P6CAN IN

Drain

W1

1

Whi

te

Blu

e

Whi

te

Blu

e

NOTE 1

White (Hi)

Blue (Low)

JUMP PINS 2 AND 3FOR ALL SYSTEM TYPES

1

0

23

45678

9

1

0

23

45678

9

REFER TO FIGURE 6 FOR CONNECTIONSTO PUMP CONTROL BOARD, MGI, AND GUN

+0−10V DC −

Assist Air Comp.

85−230 Vac

+

+−

+−

Pump Speed 2Pump Speed 1

Purge

Purge

Gun 1

Gun 2

P5-7 P5-8

Normal

Fast-1

Fast-2

Fast-3

0

1

1

0

0

0

1

1

Pump Speeds

OP

EN

4

3

2

1

SW3

Note: DIP switchSW3−1 is shownhere in the Closedposition.

Figure 5 Gateway Wiring and Setting Diagram − Analog Mode

Page 20: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway14

Part 1102107-02 � 2014 Nordson Corporation

Pump Control Board Connections and Settings

1 2 3

Prodigy Pump Control Board

P5CAN OUT

1 2 3

P6CAN IN W1

1

From Prodigy Gateway FIgure 4 or 5

Single Gun for Standard or Color-on-Demand (COD) Systems

1 2 3

Prodigy Pump Control Board

P5CAN OUT

1 2 3

P6CAN IN W1

1

From Prodigy Gateway FIgure 4 or 5

Dual Gun Standard Systems

Dual Gun Color-on-Demand Systems

1 2 3

Prodigy Pump Control Board(TOP BOARD)

P5CAN OUT

1 2 3

P6CAN IN W1

1

From Prodigy Gateway FIgure 4 or 5

1 2 3

Prodigy Pump Control Board(BOTTOM BOARD)

P5CAN OUT

1 2 3

P6CAN IN W1

1

1

0

23

45678

9

B

A

Set SW1 toPosition 2

Prodigy MGIw/Version 2.2 or

later software

8-meter Gun Cable

Prodigy Gun

Prodigy MGIw/Version 2.2 or

later softwareProdigy Gun

Set GUN NO to 3,GUN TYPE to EXTERNAL−COD

Set GUN NO to 1,GUN TYPE to EXTERNAL−COD

Prodigy MGIw/version 2.2 orlater software

Set GUN NO to 1,GUN TYPE toEXTERNAL (Standard)or EXTERNAL−COD

8-meter Gun Cable

8-meter Gun Cable

Prodigy MGI

Set GUN NO to 1,GUN TYPE toEXTERNAL(Standard)8-meter

Gun CableP/N 1076762

Prodigy MGIw/Version 2.2 or

later software

8-meterGun Cable

Set GUN NO to 2,GUN TYPE to EXTERNAL(Standard)

Prodigy GunProdigy Gun

1

0

23

456789

1 22 3 4SW2

OPEN

1 22 3 4SW2

OPEN

1 22 3 4SW2

OPEN

Set SW1 toPosition 1

1 22 3 4SW2

OPEN

1

0

23

456789

Set SW1 toPosition 1

1

0

23

456789

Set SW1 toPosition 1

Note:SW2-2 is shown in theClosed position (CODenabled).SW2-2 is open forSTD, closed for COD.

Figure 6 Pump Control Board Connections and Settings (1 of 2)

Page 21: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 15

Part 1102107-02� 2014 Nordson Corporation

Dual Gun on Dual Robot Configuration

Note: Trigger 1and trigger 2 areconnected to bothGateways.

Figure 7 Pump Control Board Connections and Settings (2 of 2)

Page 22: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway16

Part 1102107-02 � 2014 Nordson Corporation

Gun Cables For this application, you cannot use the standard automatic gun cableslisted in the Prodigy Automatic Gun manual. Use the gun cables listed onpage 18.

Prodigy MGI Settings Refer to the Prodigy Manual Gun Controller manual (P/N 1054580) forinformation on preset and configuration settings.

1. If you are using Preset Mode, turn on the MGI and program each of thepresets with the desired values.

2. For both Preset Mode and Analog mode, cycle power while pressing theNordson key. The Configuration menu appears after the MGI boots up.

3. Select SETUP and set the GUN NO (gun number).

� For Standard Systems, set the gun number to 1 or 2, depending onthe number of guns and the gun connected to the MGI.

� For Color-on-Demand Single Gun Systems, set the GUN NO to 1.

� For Color-on-Demand Dual Gun Systems, set the MGI connected topump control board A (bottom board) to GUN NO 1, and the MGIconnected to pump control board B (top board) to GUN NO 3.

4. Set the GUN TYPE:

� For standard systems set to EXTERNALFor Color-on-Demand systems set to EXTERNAL−COD

Setting the gun type to EXTERNAL or EXTERNAL−COD locks the MGIoperator interface so no changes can be made while the externalcontroller is in control. Errors can still be viewed and cleared.

Page 23: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 17

Part 1102107-02� 2014 Nordson Corporation

Operation Power On

When the Gateway is powered on, it reads the JP11, JP12, and JP13positions for mode of operation, number of guns, and type of system. Itthen sends WHO messages to find the nodes (MGIs) connected to thenetwork. The Green Power LED on the Gateway card blinks at 1 secondintervals.

Triggering When a Trigger 1 or Trigger 2 signal is received, the Gateway immediatelysends a trigger command to the MGI. No Gun Strobe signal is required.The MGI turns on the HDLV powder pump and the spray gun. The spraygun and pump will remain triggered on as long as the signal is present atthe Trigger inputs.

Gun Strobe The Gun Strobe signal tells the Gateway that the data on its inputs is stableand ready to be read. If Gun 1 Strobe is activated the Gateway reads theinputs, converts them to CAN messages and addresses them for gun 1.Gun 2 Strobe works in the same way.

NOTE: Preset values are not retained when the power to either the PLCGateway or to the MGI is cycled in EXTERNAL (gateway) mode. Thismeans that whenever power is cycled to the MGI or the PLC Gateway, therobot or PLC must send the desired preset bits (or analog values) andstrobe them in before triggering the gun.

Data Read

Gun Strobe

Changing Changing

P5−5 Gun 1or

P5−6 Gun 2

Preset Bit ContactsP5−1 to P5−4

Stable DataPreset Mode

Analog Mode

Data Read

Gun Strobe

Changing Changing

P5−5 Gun 1or

P5−6 Gun 2

Stable VoltageDC Voltage for

kV or A, Flow, Pattern

10V

0V

Figure 8 Gun Strobe

Faults Every 2 seconds the Gateway sends a heartbeat message to the MGInodes over the CAN network. If the MGI does not receive a heartbeatmessage from the Gateway for 15 seconds the MGI will display an E31error code (Gateway heartbeat missing). The MGI nodes also send outheartbeat messages. If the Gateway does not receive a heartbeat messagefrom the MGI nodes for 15 seconds, then a communication fault occurs andthe Red Fault LED is turned on. Refer to Troubleshooting in the ProdigyManual Gun Controller manual for fault codes and suggested corrections.

Page 24: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway18

Part 1102107-02 � 2014 Nordson Corporation

Parts To order parts, call the Nordson Finishing Customer Support Center at (800)433-9319 or contact your local Nordson representative. For moreinformation, go to http://www.nordson.com on the Internet.

Gateway Replacement Parts

Item Part Description Quantity Note− 1101422 GATEWAY, PLC, Prodigy, Generation III 1

1 1101454 � KIT, PCA, Prodigy PLC gateway, Generation III 1

2 288807 � FILTER, line, RFI power 1

3 131477 � FUSE, 2.00, fast-acting, 250 V, 5 x 2 2

4 288803 � POWER SUPPLY, 24, 5, 12 Vdc, 40 W 1

1

2

3 4

Figure 9 Prodigy PLC Gateway Parts

Gun Cables

Part Description Note1076762 CABLE, Prodigy bar mount gun, 8 meter A1073027 CABLE, handgun, 4 meter extension A1083912 CABLE, handgun, 6 meter extension A

NOTE A: The 8-meter cable is a special cable used only for connecting Prodigy automatic guns to Prodigy MGIcontrollers. If using the 4 meter extension, install it in between the 8 meter cable and the MGI.

Page 25: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway 19

Part 1102107-02� 2014 Nordson Corporation

Optional Enclosure Mounting Kit See Figure 2 for kit components. Use this kit to mount the Gatewayenclosure on a Prodigy Manual System stand.

Item Part Description Quantity Note− 1077918 KIT, mounting, Prodigy PLC Gateway 11 - - - - - - � BRACKET, PLC gateway 22 - - - - - - � SCREW, hex, cap, M8x 16, black 43 - - - - - - � WASHER, lock, M8, steel, zinc 84 - - - - - - � WASHER, flat, M8, steel, zinc 85 - - - - - - � NUT, hex, lock, torque, M8 86 - - - - - - � SCREW, hex, cap, M8 x 60, black 4

Page 26: Prodigy® PLC Gateway Generation III - Nordsonemanuals.nordson.com/finishing/files/Powder/1102107.pdfChange Record i 2014 Nordson Corporation Part 1102107-02 tents Change Record Revision

Prodigy� PLC Gateway20

Part 1102107-02 � 2014 Nordson Corporation

Enclosure Wiring Diagram

MAIN POWER INPOWER CORD

40W

PO

WE

R S

UP

PLY

2888

03

GR

EE

N/Y

ELL

OW

(G

ND

)

BLA

CK

GR

AY

OR

AN

GE

RE

D1

L (3

)

SK

1

N (

1)

BLACK

RED

GND(INSIDE DOOR)

GND(INSIDE ENCLOSURE)

BLU

E

(L2 −

NE

UT

RA

L)

BR

OW

N

(L1 −

HO

T)

BLACK

RED

SK

2

2 3 4 5 6

ORANGE

GRAY

(FIELD INSTALLED)

TERMINAL BLOCK

L1

L2

L1

L2

GND

TERMINALBLOCK

L2L1

L1 L2

BLU

E

(L2 −

NE

UT

RA

L)

GR

EE

N/Y

ELL

OW

(G

ND

)

BR

OW

N

(L1 −

HO

T)

(FIELD INSTALLED)

AUX. POWER OUTPOWER CORD

BR

OW

N

BLU

E

GR

N/Y

EL

BLU

E

BR

OW

N

BLUE

BROWN

LINE FILTERRFI POWER

288807

BR

OW

N

BLU

E

L1

L2

L1

L2

GND

654321

BLACK

REDP7

Power Requirement:85−230 Vac, 50−60 Hz, 1 , 21 VA

3

2

1

CA

N−

L B

LUE

CA

N−

H W

HIT

ET

O C

AN

NE

TW

OR

K

P3

Figure 10 Enclosure Wiring Diagram