The RK-300 automatically detects the right versions of the product to control. Connect the DB9 cable supplied or an Ethernet crossover cable using the same protocol as the unit connected. To control the following Seamless Switchers: Control Mode Seamless Mixer Seamless Matrix Quadra- vision Soft Edge Blending EKS500 x x (1) x EKS400 x x (1) OPS300 x x OPS200 x PLS300 x PLS200 x SVU300 x SVU200 x SMX100 x SMX200 x (1) STE100 x STE200 x SQD200 x Navigation Menu: To access the RK-300 menu, press the [EXIT/MENU] button in the control section. To highlight items in the menu which will appear on the VFD screen, turn the scroll knob left or right to the desired menu item. When you have reached the desired menu item, press the [ENTER] button in the control section to access that menu function. Pressing the [ENTER] button when a selection has been made sets the value to that selection in the RK-300 memory. When all settings have been made, press the [EXIT/MENU] button to exit sub-menus and return to the main menu. IMPORTANT: simply selecting a menu item will not set it to that value. Be sure to press the [ENTER] button when parametering the menu items. Once you have connected your RK-300 to your switcher, configure the connection settings on both devices. For a serial connection, select RS232 from the RS232/ LAN menu on both devices. (In [CONTROL] menu) For a LAN connection, select LAN from the RS232/ LAN menu on both devices (In [CONTROL] menu), and configure each device with a unique IP in the LAN setup - > RK-300 address menu. The default IP on the RK-300 is 192.168.0.15. Next, enter the IP of the device you wish to control in the Lan Setup - > Device address menu. Once your settings are correct, the RK-300 will begin to synchronize with the device, and you will be ready to begin. (Wait a minute). QUICK START GUIDE What’s in the box RK-300 settings Thank you for choosing Analog Way and the RK-300. By following these simple steps, you should be able to setup and use your powerful remote Control Keypad within minutes. Discover the RK-300 extensive capabilities and intuitive interface while configuring your first show, and unleash your creativity for a new experience in show and event management by Analog Way. RK-300 - Ref. RK-300 1 x RK-300 (RK-300) 1 x Power supply Cord 1 x DB9 (M/F) Cable 1 x Carrying Case 1 x Quick Start Guide * * Download on our website: http://www.analogway.com (1) We recommend using the Advanced Seamless Matrix Mode with an ORCHESTRA or a Remote Control Software (RCS). Button Color Usage: #1 = Source is on the main outputs Solid red: #2 = Freeze enable #3 = Stand-by button #4 = Preset Selection Solid green: #1 = Source is on Preview #2 = Function available for modification Solid orange: Unlocked sources Blinking red: Layer/source selected, and is currently active on the main output Blinking green: Layer/source selected, and is not currently active one the main output

Upload: others

Post on 24-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: QUICK START GUIDE RK-300 - Ref. RK-300 · RS232 update. This port can also provide power to operate the RK-300 when connected to a switcher. RJ-45 Connector: Connect the RK-300 to

• TheRK-300automaticallydetectstherightversionsof the product to control. Connect theDB9 cablesuppliedoranEthernetcrossovercableusingthesameprotocolastheunitconnected.

• TocontrolthefollowingSeamlessSwitchers:

Control Mode

Seamless Mixer

Seamless Matrix

Quadra-vision

Soft Edge Blending

EKS500 x x(1) x

EKS400 x x(1)

OPS300 x x

OPS200 x

PLS300 x

PLS200 x

SVU300 x

SVU200 x

SMX100 x

SMX200 x(1)

STE100 x

STE200 x

SQD200 x

Navigation Menu:Toaccess theRK-300menu,press the [EXIT/MENU]button in the control section.To highlight items in themenuwhichwill appear on the VFD screen, turn thescrollknobleftorrighttothedesiredmenuitem.Whenyou have reached the desired menu item, press the[ENTER] button in the control section to access thatmenufunction.

Pressingthe[ENTER]buttonwhenaselectionhasbeenmade sets the value to that selection in the RK-300memory.Whenallsettingshavebeenmade,pressthe[EXIT/MENU]buttontoexitsub-menusandreturntothemainmenu.

IMPORTANT:simplyselectingamenuitemwillnotsetittothatvalue.Besuretopressthe[ENTER]buttonwhenparameteringthemenuitems.OnceyouhaveconnectedyourRK-300toyourswitcher,configuretheconnectionsettingsonbothdevices.Foraserialconnection,selectRS232fromtheRS232/LANmenuonbothdevices.(In[CONTROL]menu)For a LAN connection, select LAN from the RS232/LANmenuonbothdevices(In[CONTROL]menu),andconfigureeachdevicewithauniqueIPintheLANsetup->RK-300addressmenu.ThedefaultIPontheRK-300is192.168.0.15.Next,entertheIPofthedeviceyouwishtocontrolintheLanSetup->Deviceaddressmenu.Onceyoursettingsarecorrect, theRK-300willbegin tosynchronizewiththedevice,andyouwillbereadytobegin.(Waitaminute).

QUICK START GUIDE

What’s in the box

RK-300 settings

Thank you for choosing Analog Way and the RK-300. By following these simple steps, you should be able to setup and use your powerful remote Control Keypad within minutes. Discover the RK-300 extensive capabilities and intuitive interface while configuring your first show, and unleash your creativity for a new experience in show and event management by Analog Way.

RK-300 - Ref. RK-300

1 x RK-300 (RK-300)1 x Power supply Cord1 x DB9 (M/F) Cable1 x Carrying Case1 x Quick Start Guide *

* Download on our website: http://www.analogway.com

(1) We recommend using the Advanced Seamless Matrix Mode with an ORCHESTRA or a Remote Control Software (RCS).

Button Color Usage: #1 = Source is on the main outputsSolid red: #2 = Freeze enable #3 = Stand-by button #4 = Preset Selection

Solid green: #1 = Source is on Preview #2 = Function available for modification

Solid orange: Unlocked sources Blinking red: Layer/source selected, and is currently active on the main output

Blinking green: Layer/source selected, and is not currently active one the main output

Page 2: QUICK START GUIDE RK-300 - Ref. RK-300 · RS232 update. This port can also provide power to operate the RK-300 when connected to a switcher. RJ-45 Connector: Connect the RK-300 to

Front Panel Description

WORKING WITH THE RK-300

Toggle Standard or Mosaic mode when available.

Switch between Status & Control Mode.Exit from menu.

Buttons and functions are available according to the unit wich is controlled.

PREVIEW

EXIT/MENU

BACKGROUND/FRAME: Select the Frame Layer.BACKGROUND LIVE/ PIP 1: Select the Live Layer/PIP1.PIP 2: Select the PIP2 live Layer.PIP 3: Select the PIP3 live Layer.LOGO 1: Select the Logo 1 Layer.LOGO 2: Select the Logo 2 Layer.DSK: Shortcut to the Keying/Titling menu for the selected source.

#1 L/ F 1: Press to access source #1, Frame #1 or Logo #1.#2 L/ F 2: Press to access source #2, Frame #2 or Logo #2.#3 L/ F 3: Press to access source #3, Frame #3 or Logo #3.#4 L/ F 4: Press to access source #4, Frame #4 or Logo #4.#5 L/ F 5: Press to access source #5, Frame #5 or Logo #5.#6 L/ F 6: Press to access source #6, Frame #6 or Logo #6.#7 L/ F 7: Press to access source #7, Frame #7 or Logo #7.#8 AL/ F 8: Press to access source #8, Frame #8 or Logo #8 or Animated Logo.DVI 1 to DVI 2: Press to access DVI #1 or DVI #2.SDI 1 to SDI 4: Press to access SDI #1,2,3 or 4.BLACK: Change the active layer to Black to clear a layer or PIP.FREEZE: Freeze the input linked to the current layer on MAIN.

OUTPUT #1: Press to select the Output #1, select a layer and a source then press [TAKE].OUTPUT #2: Press to select the Output #2, select a layer and a source then press [TAKE].

SHIFT: Secondary function selection button.

INPUT

MATRIX

SHIFT

LAYER

Page 3: QUICK START GUIDE RK-300 - Ref. RK-300 · RS232 update. This port can also provide power to operate the RK-300 when connected to a switcher. RJ-45 Connector: Connect the RK-300 to

* accessible via the Shift KeyPress on [TAKE] allows to display the pre-selected sources onto the MAIN output with the selected effects.

VOL: Volume adjustment of the MAIN output (adjust with the knob ◄ ►).Button is blinking during the adjustment. This function will be dis-missed after 2 seconds delay or after pushing [ENTER] button.

MUTE: Toggles the audio mute of the Main output. Button illuminates when volume is muted.

Easy adjustments (size or position) with this mini joystick. Adjust the selected PIP or Logo, X-Axis (Left/Right), Y-Axis (Up/Down) and click to change the mode (position or size).

ENTER button validates a selected item.

Adjust Sources:

Chose the selected source Aspect Out as:1:1: No scaling, layer size has no effectCENTERING*: Centered (aspect ratio preserved, black bars around source)FULL*: Fullscreen (aspect ratio distorted)CROP*: Cropped (aspect ratio preserved, extra image cropped ----ZOOM: Configures the Layer Zoom----SIZE: Resize the active layer with the mini joystickPOS: Adjust PIP Layer or Logo Position with the mini joystick

CUT: Select Cut as the current transition type.

FADE: Select Fade as the current transition type.

USER 1: Selects the customized transition configured in the Control menu.USER 2: Select User #2 as a customized transition in the Control menu.

Preset section: Recalls stored presets from the device. Store presets using Menu -> Preset-> Store Preset.

P1/P5: Select P #1 as a customized preset or P #5 by SHIFT function.P2/P6: Select P #2 as a customized preset or P #6 by SHIFT function.P3/P7: Select P #3 as a customized preset or P #7 by SHIFT function.P4/P8: Select P #4 as a customized preset or P #8 by SHIFT function.

Allow to copy the previous Current Preset in the Next Preset at the end of a [TAKE].

Mini T-Bar to control effect level.

Available when controling a device which offers Quadravision.W1: Change the active layer into the Window #1.W2: Change the active layer into the Window #2.W3: Change the active layer into the Window #3.W4: Change the active layer into the Window #4.

Allow to scroll through the different menus

VOLUME

CONTROL

T-BAR

TOGGLE PRESET

TAKE

QUADRAVISION

ENTER

ADJUSTMENT

POSITION

EFFECT/PRESET

Page 4: QUICK START GUIDE RK-300 - Ref. RK-300 · RS232 update. This port can also provide power to operate the RK-300 when connected to a switcher. RJ-45 Connector: Connect the RK-300 to

Rear Panel Description

Menu Tree

Going further with the RK-300The RK-300 allows for remote control of all available device features. Please check your device manual for more information on device operation and usage. Please check our website for further information: www.analogway.com

Version : 4.10 - 04/06/12 - M3.0 Code : 140116

RS-232 PORT: This 9-pin Female D connector provides RS-232 port serial communication with the switcher and also to upgrade the RK-300. A DB9 F/F crossover cable (not supplied) is required for an RS232 update. This port can also provide power to operate the RK-300 when connected to a switcher.

RJ-45 Connector: Connect the RK-300 to a 10/100 BT Ethernet LAN using this female RJ-45 connector: used to control the switcher and also to upgrade the RK-300. Please see the updater software instructions for more information. (Crossed cable for a direct link between RK-300 unit, straight cable through a hub.)

DC Power connector: Plug a Jack coaxial 5.5 - 2.1 - 9mm - external GND. 9/12 Vdc - 1A.

DC

RS-232

RJ-45

Versions

RS232/LAN

LAN setup

Key locking

Prog. keys

LCD brightness

Key brightness

Standby

Default values (L2)

LAN Update

RS232

Version: 1.00 BETA

I3=xxxx I4=xxxx

Boot: 1.00 BETA

O=0000

CS2=xxxx

I1=xxxx I2=xxxx

CS1=xxxx

CS3=xxxx

LAN

TCP

All

Fade

UDP

Menus

User 1 User 2

RK-300 address... Remote address... Gateway address... RK-300 port... Remote port... (L1)

Netmask... Default setup... (L2)

RK-300 CONTROL

(L1) UDP only(L2) Confirmation asked(L3) Only for User1& User2

WarrantyAll Analog Way products have a 3 year warranty on parts and labor, back to factory, but do not include faults resulting from user negligence, special modifications, electrical surges, abuse (drop/crush), and/or other unusual damage.

Please note: The included carrying case and protective foam is not covered under warranty.

NOTE: The latest firmware upgrade is always available on our website: http://www.analogway.com

Allow to secure with a KensingtonTM Lock.

Type (L3)

Direction (L3)

Effect duration