resnet: explaining the thermal bypass checklist
DESCRIPTION
The Thermal Bypass Checklist is a list of 16 items that must be completed in each ENERGY STAR home.TRANSCRIPT
![Page 1: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/1.jpg)
Explaining the Thermal
Bypass Checklist
Ed Minch,
Energy Services Group
Kelly Parker, GWS
![Page 2: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/2.jpg)
ENERGY STARThermal Bypass Checklist – WHY?
ENERGY STAR is roughly doubling the number of houses verified
each year, and there are now enough houses out there to see trends:
![Page 3: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/3.jpg)
Early History of the Bypass
During the oil embargo of
early 70’s, a research team
at Princeton University did
basic building diagnostic
research. They developed
the Blower Door and proved
that Air Infiltration is a
problem, but still had a
“mystery loss”. They
adapted Infrared and found
the “Thermal Bypass”
This article in the February 1981
issue of National Geographic was the
first time the term was in general use.
![Page 4: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/4.jpg)
Energy Star did their research and found that there
are places where many homes, even though tight
on the blower door, were not properly sealed.
They came up with the Thermal Bypass Checklist
to cover these areas.
Many of the items on
the TBC are required
in the 2004
International Code
Supplement and will be
a part of the 2006 IECC
![Page 5: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/5.jpg)
The Thermal
Bypass
Checklist is a
list of 16 items
that must be
completed in
each ENERGY
STAR home.
![Page 6: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/6.jpg)
1) Air barrier and Thermal Barrier in AlignmentInsulation is installed in full contact with the air barrier to provide
continuous alignment of the insulation with the air barrier
![Page 7: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/7.jpg)
1) Air barrier and Thermal Barrier in Alignment
![Page 8: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/8.jpg)
2) Shower/tub at exterior wallExterior walls have been enclosed on all six sides
and exterior walls have been fully insulated
![Page 9: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/9.jpg)
To ensure comfort it is very important to
make sure there are no leaks in walls behind the tubs
2) Shower/tub at exterior wall
We find this to be a very serious problem
![Page 10: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/10.jpg)
2) Shower/tub at exterior wall
Packed out wall at head oftub open to attic.
Tub and shower open toattic behind.
!” strips added to makesheetrock line up with tub
flange – !” slot at top of wall.
![Page 11: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/11.jpg)
2) Shower/tub at exterior wall
Soaking tub base open toknee wall attic
Sealed tight
![Page 12: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/12.jpg)
3) Insulated floor above garageAir barrier is installed at any exposed edges of
insulation and insulation is installed to maintain
permanent contact with the underside of the floor sub
floor decking.
![Page 13: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/13.jpg)
3) Insulated floor above garage
Air dams at both ends of open joistsunder room over garage
Air dams under exterior wall of roomabove garage
![Page 14: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/14.jpg)
3) Insulated floor above garage
Improper insulation!It must touch the
surface it is intendedto insulate
![Page 15: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/15.jpg)
4) Attic Knee WallsContinuous top and bottom plates are installed with
an air barrier on an attic side of insulated walls,
including exposed edges of insulation at joists and
rafters, and insulation is in complete alignment with
the interior finish and the attic side air barrier.
Batt falling from back of wallSmall gable party wall showing batt
falling off the back of wall
![Page 16: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/16.jpg)
4) Attic Knee Walls
Short Kneewall Covered
Tall Kneewall Covered
Kneewall Open to Attic Rafters
Kneewall Covered at Attic, Not Heated Space
![Page 17: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/17.jpg)
4) Attic Knee Walls
Air damming of the floor cavity below a kneewall.
Sealed Tight.6th side on the wall above.
![Page 18: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/18.jpg)
4) Attic Knee Walls
Joist cavity open to attic on 2 sides -sealed tight.
Looking into the second floor kneewalljoist cavity.
![Page 19: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/19.jpg)
4) Attic Knee Walls
Tightly sealed ductwork. Looking from an attickneewall into joist cavity.
![Page 20: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/20.jpg)
5) Attic Access Panel/ Pull Down StairAttic access panel or stair is fully gasketed for an
airtight fit, and covered with insulation that is attached
and fits snugly in the framed opening
Attic hatch with too small batt.
Attic hatch with nogasket. Pull down stair showing
structural framing and bolts,no insulation - very difficult togasket durably, and impossible
to insulate adequately.
![Page 21: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/21.jpg)
5) Attic Access Panel/ Pull Down Stair
Self-stick gasket material.
Insulation installed to edge of hatch cover.
Wrong way to insulate - air barrier andinsulation not aligned.
![Page 22: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/22.jpg)
6) Cantilevered FloorAir barrier spans cantilever and any exposed edges
of insulation, and floor framing is completely filled with
insulation or it is installed to maintain permanent
contact with sub floor decking.
Three bay windows and a rear overhang. Two bay windows, a fireplace andrear overhang.
![Page 23: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/23.jpg)
6) Cantilevered Floor
Cantilevered floor not
sealed and not insulated
properly.Cantilever before
siding – “j” channel will
hide this.
![Page 24: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/24.jpg)
6) Cantilevered Floor
Daylight showing leaking cantilever.Tight seal - now insulation willbe installed full-depth.
![Page 25: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/25.jpg)
6) Cantilevered Floor
Insulation - full depth of floor joist.
Alternative - overhang sealed and insulatedfirst, then air dam sealed tight. In small
overhangs, this tends to make floor colder.
![Page 26: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/26.jpg)
7,8) Duct, Piping, Flue Shaft Penetrations
Opening is fully sealed with solid blocking, flashing
foam and caulk, and clearance between flue and
combustibles is properly closed with UL approved
collars and sealed with fire-rated sealant.
Chase open from attic intointerior wall.
Typical chase, no metal collar at fluewith improper flue clearance to OSB.
![Page 27: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/27.jpg)
7,8) Duct, Piping, Flue Shaft Penetrations
The mother of all chases.
![Page 28: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/28.jpg)
9) Attic Eaves
Solid baffles are provided at framing bays to
avoid wind washing of insulation.
![Page 29: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/29.jpg)
10) Dropped Ceiling / Soffit
Duct soffit sealed with styrofoamand foam.
Kitchen soffit sealed withstyrofoam and foam.
![Page 30: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/30.jpg)
10) Dropped Ceiling / Soffit
Kitchen soffit sealed at joist level withstyrofoam & foam.
Archway between 2 rooms forming‘soffit’ - sealed inside with foam.
![Page 31: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/31.jpg)
10) Dropped Ceiling / Soffit
Very difficult soffit - under heated space and open to unheated space. Duct is insulated‘outside’ and not ‘inside’, wire runs ‘outside’ to ‘inside’. No thermal envelope.
![Page 32: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/32.jpg)
11) Fireplace WallAir barrier is fully aligned with insulated framing in framed
shaft behind fireplace, and any gaps are fully sealed with
caulk foam, or tape.
![Page 33: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/33.jpg)
11) Fireplace Wall
Typical fireplace chase. Treat this area likea little room. Every surface should be
sealed & insulated.
Piece of Thermo-Ply,sheet metal, drywall,
or other rigid materialcut to fit, and installed
with R-30 above.
![Page 34: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/34.jpg)
11) Fireplace Wall
Seal every crack and hole inthe chase.
Insulate the walls. ceiling is already done and underthe floor will be insulated from the basement.
![Page 35: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/35.jpg)
11) Fireplace Wall
Seal theflange atframing.
Seal theflue to
the flange.
![Page 36: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/36.jpg)
11) Fireplace Wall
Wood burningfireplace -3/4” furring stripsopento attic above
![Page 37: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/37.jpg)
12) Staircase Framing at Exterior Wall/Attic
Air barrier is fully aligned with insulated framing and
any gaps are fully sealed with caulk or foam.
Stair to third
floor open to
kneewall and
interior wall.
![Page 38: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/38.jpg)
13) Recessed LightingAirtight IC-rated recessed light fixtures are sealed
to drywall with gasket, caulk, or foam.
Poor insulation of an IClight.
Blower Door shows airleakage at drywall joint.
![Page 39: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/39.jpg)
13) Recessed Lighting
Unacceptable. Does notmeet most codes because of
multiple holes.
Washington State EnergyCode Approved.
Still need to gasket or caulkat drywall.
![Page 40: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/40.jpg)
14) Porch RoofAir barrier is installed at the intersection of
the porch roof and exterior wall
Cold air between heated floors - coming infrom porch across front of house.
![Page 41: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/41.jpg)
14) Porch Roof
From outside, porch is openinto ‘Cape Cod’ area of the
second floor.
From inside, heated floor aboveis exposed to outside air.
![Page 42: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/42.jpg)
14) Porch Roof
Air dams installed - ready for insulation.
![Page 43: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/43.jpg)
14) Porch Roof
Air above vinyl porch ceiling can getinto cavity between floors.
View into house from outside
Porch ceiling around 2 sides of the housewith open web trusses and no band board,
sealed with styrofoam and foamCavities open to house sealed
![Page 44: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/44.jpg)
15) Whole House Fan Penetration at AtticAn insulated cover is provided that is gasketed or
sealed to the opening from either the attic side or
ceiling side of the fan
But we haven’t
seen one of these
in a new house in
the last 15 years
![Page 45: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/45.jpg)
16) Common Walls Between Dwelling UnitsAir barrier is installed to seal the gap between a gypsum shaft
wall and the structural framing between units in duplex or
townhouse construction.
IR of air in 1st floor party wall of 2 story house.
Front door at party wall.
![Page 46: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/46.jpg)
16) Common Walls Between Dwelling Units
From the outside, cornerbetween 2 units will get
covered by ‘J’ channel siding,but will still leak air.
Same gap - fromthe inside.
Sealed party wall.
![Page 47: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/47.jpg)
16) Common Walls Between Dwelling Units
Stud wall 1” from party wall
Stud wall 1” from party wall
Stud wall 1” fromblock party wall
Area at band is just asimportant as the wall itself
![Page 48: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/48.jpg)
Remember the first item on the list?1) Air barrier and Thermal Barrier in Alignment The other 15 are really the same thing.
![Page 49: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/49.jpg)
What You Don’t Want To See
Caulk where not necessary.
Caulk where not necessary.Wasted time and money.
![Page 50: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/50.jpg)
What You Don’t Want To See
Airtight foam on pervious rock wool.
Plenty of caulk, but no airtight back oninsulation in attic.
![Page 51: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/51.jpg)
InspectingIf you are not removing insulation to inspect
these bypasses, you are missing them!
Sound insulation in place. Party wall properly sealed.
The wire hole is sealed,but the party wall isn’t.
![Page 52: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/52.jpg)
Inspecting
Insulation in place. End of front porch beam sealed.
![Page 53: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/53.jpg)
Inspecting
Insulation in place.
Wall sealed.Fireplace not sealed, insulation
in the wrong place.
![Page 54: RESNET: Explaining the Thermal Bypass Checklist](https://reader033.vdocuments.net/reader033/viewer/2022052215/55559732b4c905a5178b4f1e/html5/thumbnails/54.jpg)
Inspecting
Insulation in place. Band joist between floors sealed.