roxburgh dam combined discharge of spillway and sluice into the same chute peter silvester – civil...
TRANSCRIPT
Roxburgh DamCombined Discharge of Spillway and Sluice
into the same Chute
Peter Silvester – Civil Engineer Contact EnergyGrant Webby – Principal Hydraulic Engineer Opus International Consultants
© Contact Energy Limited 2
Roxburgh Dam - Location
Roxburgh Dam
© Contact Energy Limited 3
Roxburgh Dam
Commissioned 1956
50m high concrete gravity
320 MW power station
Mean flow 507 cumecs
PMF 7,000 cumecs
© Contact Energy Limited 4
Roxburgh Dam Spillway
Three Spillway Gates15.2m wide x 13.4m high.Discharge capacity 4,750 cumecs
Two diversion sluices7.1m wide x 8.7m high.Discharge capacity 2,900 cumecs.
Combined total discharge capacity 7,650 cumecs.
© Contact Energy Limited 5
Roxburgh Dam Spillway
Spillway chute 3 dewatered
Diversion Sluices
Sluices
7.1m wide 8.7m high
© Contact Energy Limited 7
Spillway – Sluice Long Section
© Contact Energy Limited 8
Physical Hydraulic ModelUniversity of Auckland
Tests covered:
• Sluice only operation - 25
• Spillway only operation - 25
• Combined operation -
125
• Total tests
175
© Contact Energy Limited 9
Physical Hydraulic Model Observations
© Contact Energy Limited 10
Physical Hydraulic Model Results
Maximum pressures along sluice
© Contact Energy Limited 11
Physical Hydraulic Model
Rooster TailsSluice only operation
© Contact Energy Limited 12
Gate Tests
Jan 2013
Sluice 2 opened 6.77m (78%).
Discharge 862 cumecs.
© Contact Energy Limited 13
Sluice Gate Test
© Contact Energy Limited 14
Conclusions
• Physical hydraulic model investigations supported by prototype testing have successfully proved for the Roxburgh Dam case that simultaneous discharge from a spillway gate and a low level sluice gate into the same chute is feasible and will produce smooth merged flow lines.
• For sluice only operation the discharge will not pressurise the sluice tunnel.
• Spillway only operation will pressurise the sluice tunnel only at high lake levels and gate openings greater than 40%.
• Combined spillway and sluice operation will pressurise the sluice tunnel only at high lake levels and spillway gate openings greater than 40%.
• The water levels induced in the sluice gate chamber by the back pressure from spillway only or combined spillway and sluice operation are unlikely to flood the middle gallery in the dam where the sluice gate controls are located. However further prototype tests are desirable to confirm the extreme water level values observed in the model tests.
• Although the sluice is back pressured by the spillway the discharge from the sluice is not reduced.
• ‘Rooster tail’ behaviour along each side wall at the sluice exit into the spillway chute could threaten the access bridge to the power station under high sluice only flow conditions at a high lake level.
• Roxburgh Dam can safely pass the PMF inflow using the combined discharge from both the spillway and sluice gates fully open at a lake level of RL 132.3m (I.e. with 1.2m freeboard).