russellstoll - wesco · russellstoll application guide this catalog has been divided into sections...

3
Russellstoll Computer System Plugs, Connectors and Receptacles - Ordering Information 2P/ 3W 3P/ 4W 4P/ 5W- 15/ 20 Amp 30 Amp 50 Amp 20 Amp 30 Amp 50 Amp 60 Amp 30 Amp Voltage Up To 600 VAC/ 250VDC 125VAC 250 VAC Up To 600 VAC Up To 600 VAC Up To 600 VAC/ 250 VDC Up To 600 VAC Up To 600 VAC 250 VDC Up To 600 VAC 30Y 120/208 VAC Plug Safety Polarization (+~+\ v«y ^ w (*~*\ VVy (+~*\ v*y (•~*\ V«y (*~*\ ^y f+~^\ v^3/ f*~^\ ^•J /•"•x ^€5^ Angle Type ® MaxGard Std. Cable** Bushing 0.625" 0.455" 0.405" 0.625" 0.455" 0.405" 0.625" 0.455" 0.405" 0.760" 0.700" 0.625" 1.000" 0.925" 0.750" 0.688" 0.625" 0.606" 1.100" 1.000" 0.875" 0.760" 1.000" 0.925" 0.750" 1.375" 1.188" 1.020" 0.750" 0.775" Plugs % FS/FD* Aluminum 3720 3720U1 3720U2 3750 - 3730 3760 - 7328-78 A - ^ Spec Grade UL94-5VA 3720DP (0.375) 3720DP/0455 3720DP/0405 3720DPU1 (0.375) 3720DPU1/0455 3720DPU1/0405 37200 PU2 (0.375) 3720DPU2/0455 3720DPU2/0405 3750DP 3730DP/0625 3730DP 3760DPG/1100 3760PDG/1000 3760PDG/0875 3760DPG0760 - - - <& See Bushing Chart DuraGard™ UL94-VO* 9P23UO 9P23U1 9P23U2 9P33UO 9P53UO 9P24UO 9P34UO* 9P54UO 7328DP/1375 7328DPt 7328DP/0750 DS3516MPDP+ Connectors % FS/FD Aluminum 3913 3913U1 391 3U2 3933B - 3914 3934B - 7428-78 A DS3516FP+ ^ * <& DuraGard™ UL94-VO* 9C23UO 9C23U1 9C23U2 9C33UOB 9C53UO 9C24UO 9C34UO+B 9C54UO - - Receptacles 1 FS/FD* Aluminum 3743 3743U1 3743U2 3753B - 3744 3754B - DS3516FR+ P' -."*'•.. ' DuraGard™ UL94-VO* 9R23UOWT 9R23U1WT 9R23U2WT 9R33UOWTB 9R53UOW* 9R24UOWT 9R34UOWTB 9R54UO*T SCF7324-78 - Note: All 20A devices are compatible. 30A FS/FD receptacles and connectors will accept all styles of mating plugs. * For a more complete listing of UL 94-VO rated devices, consult DuraGard information on Pages 44-54. ** Consult Factory for additional cable bushing sizes not listed, t 7328 DP series thermoplastic can replace 7328 metallic. * 30A FS/FD Aluminum plugs may not directly exchange with DuraGard plugs. FS/FD metal mating devices must be used. . Standard 0.750 Bushing. . DuraGard receptacles and connectors 30/50A will accept only DuraGard or Spec Grade. FS/FD Aluminum 30A plugs must be used with FS/FD metal connectors or receptacles.. A Angle Type Line + MaxGard Line for further information see pages 9-29. T Requires 3711A conduit FD box or 3781A DSFD Box (50A). ThomasiBetts 152 © 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COITl

Upload: others

Post on 17-Jun-2020

109 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Russellstoll - WESCO · Russellstoll Application Guide This catalog has been divided into sections based on standard application groups. Each application group has been color-coded

RussellstollComputer System Plugs, Connectors and Receptacles - Ordering Information

2P/3W

3P/4W

4P/5W-

15/20

Amp

30Amp

50Amp

20Amp

30Amp

50Amp

60Amp

30Amp

VoltageUp To

600 VAC/250VDC

125VAC

250 VAC

Up To600 VAC

Up To600 VAC

Up To600 VAC/250 VDC

Up To600 VAC

Up To600 VAC250 VDC

Up To600 VAC

30Y120/208

VAC

PlugSafety

Polarization

(+~+\v«y

w(*~*\VVy(+~*\v*y(•~*\V«y

(*~*\^y

f+~^\v^3/

f*~^\^•J

/•"•x^€5^Angle Type

®MaxGard

Std.Cable**Bushing

0.625"0.455"0.405"

0.625"0.455"0.405"

0.625"0.455"0.405"0.760"0.700"0.625"1.000"0.925"0.750"0.688"0.625"0.606"1.100"1.000"0.875"0.760"1.000"0.925"0.750"1.375"1 .188"1.020"0.750"

0.775"

Plugs

%FS/FD*

Aluminum

3720

3720U1

3720U2

3750

-

3730

3760

-

7328-78A

-

Spec GradeUL94-5VA

3720DP (0.375)3720DP/04553720DP/0405

3720DPU1 (0.375)3720DPU1/04553720DPU1/0405

37200 PU2 (0.375)3720DPU2/04553720DPU2/0405

3750DP

3730DP/06253730DP

3760DPG/11003760PDG/10003760PDG/08753760DPG0760

-

-

-

<&See Bushing

ChartDuraGard™UL94-VO*

9P23UO

9P23U1

9P23U2

9P33UO

9P53UO

9P24UO

9P34UO*

9P54UO

7328DP/1375

7328DPt7328DP/0750

DS3516MPDP+

Connectors

%FS/FD

Aluminum

3913

3913U1

391 3U2

3933B

-

3914

3934B

-

7428-78A

DS3516FP+

^ *<&

DuraGard™UL94-VO*

9C23UO

9C23U1

9C23U2

9C33UOB

9C53UO

9C24UO

9C34UO+B

9C54UO

-

-

Receptacles

1FS/FD*

Aluminum

3743

3743U1

3743U2

3753B

-

3744

3754B

-

DS3516FR+

P'

-."*'•.. '

DuraGard™UL94-VO*

9R23UOWT

9R23U1WT

9R23U2WT

9R33UOWTB

9R53UOW*

9R24UOWT

9R34UOWTB

9R54UO*T

SCF7324-78

-

Note: All 20A devices are compatible. 30A FS/FD receptacles and connectors will accept all styles of mating plugs.* For a more complete listing of UL 94-VO rated devices, consult DuraGard information on Pages 44-54.

** Consult Factory for additional cable bushing sizes not listed,t 7328 DP series thermoplastic can replace 7328 metallic.* 30A FS/FD Aluminum plugs may not directly exchange with DuraGard plugs. FS/FD metal mating devices must be used.. Standard 0.750 Bushing.. DuraGard receptacles and connectors 30/50A will accept only DuraGard or Spec Grade. FS/FD Aluminum 30A plugs must be used with FS/FD metal connectors or receptacles..A Angle Type Line+ MaxGard Line for further information see pages 9-29.T Requires 3711A conduit FD box or 3781A DSFD Box (50A).

ThomasiBetts152 © 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COITl

Page 2: Russellstoll - WESCO · Russellstoll Application Guide This catalog has been divided into sections based on standard application groups. Each application group has been color-coded

RussellstollApplication GuideThis catalog has been divided into sections based on standard application groups. Each application group has been color-coded for your convenience. Below is a description of each of the six general categories Russellstoll products fall in.Applications are not limited to those listed below.

Heavy Industrial / Marine Applications: Outdoor, Severe or High Abuse Environments

|£ • Industrial hook-ups• Shdre to ship power connections

stations• Portable generator sets• Mills & process plants

• Agriculture• Portable power connections• Aerospace manufacturing and

airports• Lift stations

• Irrigation & wastewater equipment• Industrial and shipyard welding• Power distribution centers• Job site power: For telephone power

and communications equipment

Washdown & Light Marine Applications: Watertight / WaterproofFood processing plantsPharmaceutical manufacturing

Bottling and beverage plantsBarge and workboat applications

Pulp & paper factoriesOutdoor construction sites

Industrial and Commercial Applications

L » Entertainment (lighting & sound • Computer related equipmentsystems) • Welding installations

• Machinery

Construction sitesFacilities electrical power

Control Circuit and Industrial / Interlock ApplicationsAutomotive/Industrial Interlock plugs under full load.systems were designed for the , Automatic pressneeds of the manufacturing , , ,industry. These devices are used ' HeavY dutV Portable weldingwhere safety requirements mandatea mechanically interlocked systemfor connection and removal of

Portable systemsMachine tool control or Servo systems

1 Shipyard maintenance power1 Battery chargers1 Automated welder applications• Food processing1 Temporary power connections

Hazardous Location Applications: Class I, Div. 1 / Class II, Div. 1• Aerospace • Petroleum • Food processing• Steel mills and mining • Chemical • Waste treatment

Computer Systems: Data Center and OEM ProductsRaised Floor Applications • Main Power Connections • Critical power for test,

instrumentation, telephone andmedical equipment

ThomasiBetts© 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COm

Page 3: Russellstoll - WESCO · Russellstoll Application Guide This catalog has been divided into sections based on standard application groups. Each application group has been color-coded

RussellstollComputer System Plugs, Connectors and Receptacles

Over 30 years ago, Russellstoll offered the first pin andsleeve connectors that met the demanding needs of theData Processing industry and we've been leading the wayever since.The expanding technology of the Computer System Industryis creating more sophisticated applications which require asafe, reliable connection that exceeds the tough demands oftoday's applications. Russellstoll's commitment to excellenceoffers you that and more... Safety, Durability, Reliability and

Performance on our complete line of plugs, receptacles andconnectors.Pin & Sleeve power connections are chosen for ComputerSystems interconnections because of the absoluteperformance required in today's mainframe and peripheralinstallation. Pin & Sleeve connections have been proven tobe 1- times more reliable in service than any bladed device.Data centers stay in service, because Russellstoll staysconnected.

Quick Selection Chart

SERIES* FS/FD Spec Grade DuraGard™ Spec Grade

Available Ranges (Amp) 2 0 & 3 0 2 0 & 3 0 20, 30 & 50 30(IEC)

Safety Grade™ UL Flame ratedHigh-Temp Thermoplastic

UL94-VOAluminum UL94-5VA UL94-VO UL94-VO

Easy-to-WireRear loaded interiors

Single Rated SafetyVoltage Polarizations

20A 20A30A

20A30A50A

30A(9h - IEC)

Waterproof 0-Ring Seal(pins, sleeves & interiors)

2nd Internal Ground Lug(cable shielding alt.) (optional)

External Cable Clamp

External Gland Nut Lock

' 60A devices are specially designed versions of Russellstoll Angle Type (73280P)

E2630

LR14096

TCi V For TuV listed devices, contact Technical Support ThomasiBetts© 2001 Thomas & Belts Corporation. Specifications are subject to change without notice. WWW.tnb.COID 151