WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts reserves the right to change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. ©Watts 2010 Version 4.0 1039 SECTION 19 Commercial rO Systems

Upload: others

Post on 13-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

WaTEr QualITy PrOduCTS

Catalog 10

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts reserves the rightto change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to makesuch changes and modifications on Watts products previously or subsequently sold.

©Watts 2010 Version 4.0 1039

SECTION 19

Commercial rO

Systems

Placeholders_Cat10_Layout 1 10/7/10 10:18 AM Page 19

Page 2: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

R13 Compact Wall Mount RO

Page 3: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Standard Features • Powder coated steel frame

• Inlet solenoid valve

• 20” prefilter

• Prefilter pressure gauge

• Multistage centrifugal pump

• Low-pressure protection with

microprocessor auto reset

• 2 1/2” liquid filled pump pressure gauge

• Stainless steel pressure vessel(s)

• Product flow meter

• Reject flow meter

• Concentrate needle valve

• Non metallic recycle needle valve

• Feed water and product water TDS monitor

• Whole house

• Boiler feed water

• Humidifiers

• Greenhouses

• Process Water

• Electronics

Applications

Model: R4X40-1

Best Seller.

Try it today!

R4X40-1 R4X40-2 R4X40-3-230

Maximum Productivity (gallons per day) 2200 4400 6600

Recovery (user adjustable) 15 - 75 % 25 –75% 32 - 75 %

Number Of Membranes 1 2 3

Feed Water Required (maximum) 10gpm 12 gpm 14 gpm

Drain Required (maximum) 10gpm 12 gpm 14 gpm

Motor Horse Power 4-Mar 1 1 1/2

Electrical Requirement* 15 amps 20 amps 12 amps

Dimensions W x D x H 20 x 20 x 50 20 x 20 x 50 20 x 26 x 50

Shipping Weight (estimated lbs) 120 150 180

PART NUMBER DESCRIPTION

R2353-SD Product float switch

R2288-165 165 gal tank whole house option*

R2288 300 gal tank whole house option*

R2288-500 500 gal tank whole house option*

Specifications Options

*Includes atmospheric storage tank, product float switch, and

repressure pump with built in controls.

Notes: Maximum production based on a feed water of 77°F, SDI < 1, 1000 ppm TDS, and pH 7. Individual membrane productivity may

vary (± 15%). May be operated on other feed waters with reduced capacity. Percent Rejection is based on membrane manufactures

specifications; overall system percent rejection may be less. *R4X40-3 is available only in 230-volt single phase.

Models

Note: For indoor installation only.

Membrane Size 4” x 40”

Average membrane rejection 98%

Feed Water Connection 3/4" NPTF

Prefilter 2.5” x 20”

Product Water Connection 5/8" tubing OD

Reject Water Connection 5/8" tubing OD

Feed Water Pressure (minimum) 10 psi

Electrical Requirement * 120 VAC 60 Hz

R4X40 Series Whole House ROThree models for flow rates up to 6,600 GPD

Page 4: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

R4X40-1-220-DLX R4X40-2-220-DLX R4X40-3-220-DLX

Maximum Productivity (gallons per day) 2200 4400 6600

Recovery (user adjustable) 15 - 75 % 25 –75% 32 - 75 %

Number Of Membranes 1 2 3

Feed Water Required (maximum) 10gpm 12 gpm 14 gpm

Drain Required (maximum) 10gpm 12 gpm 14 gpm

Motor Horse Power 3/4 1 1 1/2

Electrical Requirement 8 amps 10 amps 12 amps

Dimensions W x D x H 20 x 20 x 50 20 x 20 x 50 20 x 26 x 50

Shipping Weight (estimated lbs) 120 150 180

PART NUMBER DESCRIPTION

R2350-SD Product float switch

R2288-165 165 gal tank whole house option*

R2288 300 gal tank whole house option*

R2288-500 500 gal tank whole house option*

R4X40 Deluxe Series Whole House ROThree models for flow rates up to 6,600 GPD

Added Capabilities • Input for auto shut-off when storage tank is full. • input for auto shut-off when pre-treatment is

in regeneration..

Standard Features • Powder coated steel frame • Inlet solenoid valve • 20” prefilter • Prefilter pressure gauge • Multistage centrifugal pump • Low-pressure protection with microprocessor auto reset • Tank level input (dry contact) • Pretreatment interlock input (dry contact) • 2 1/2” liquid filled pump pressure gauge • Stainless steel pressure vessel(s) • Product flow meter • Reject flow meter • Concentrate needle valve • Non metallic recycle needle valve • Feed water and product water TDS monitor

• Whole house • Boiler feed water • Humidifiers • Greenhouses

• Process Water • Electronics • Car wash spot-free

Applications

SpecificationsOptions

*Includes atmospheric storage tank, product float switch, andrepressure pump with built in controls.

Notes: Maximum production based on a feed water of 77°F, SDI < 1, 1000 ppm TDS, and pH 7. Individual membrane productivity may

vary (± 15%). May be operated on other feed waters with reduced capacity. Percent Rejection is based on membrane manufactures

specifications; overall system percent rejection may be less.

Models

Model: R4X40-Deluxe

Note: For indoor installation only.

Membrane Size 4” x 40”

Average membrane rejection 98%

Feed Water Connection 3/4" NPTF

Prefilter 2.5” x 20”

Product Water Connection 5/8" tubing OD

Reject Water Connection 5/8" tubing OD

Feed Water Pressure (minimum) 10 psi

Electrical Requirement 230 VAC 60 Hz, 1 PH

Page 5: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

R12 Series Wall-Mounted RO Systems

Compact, Wall-Mounted Systems

Four models for flow rates to 1200 GPD.

Standard Features (Package #1)

• Stainless steel frame

• Automatic inlet valve

• Pre-filter housing and cartridge, 10"

• Procon pump (brass)

• 1/2 HP motor

• Liquid filled pump pressure gauge (2-1/2")

• Stainless steel pressure vessels

• Needle valve for concentrate line

• Needle valve for recycle line

• Check valve for product water (stainless steel)

• Product pressure switch with Auto/Off

• Low-pressure shut-off with automatic restart

Additional Features Included In Package #2

• Pre-filter pressure gauges

• Product water flow meter

• Reject water flow meter

Additional Features Included In Package #3

• Automatic fast flush for concentrate

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature

conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.

Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro® FPMB5-978 melt blown cartridge.

Systems are designed for use with municipal and well water.

R12-1200-2 system with optional legs

*Includes 300 gallon tank, product water float switch andrepressurization pump with built-in controls.

Page 6: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

R14 Series Wall-Mounted RO Systems

Compact, Wall-Mounted Systems

Three models for flow rates to 5400 GPD,

available with brass and stainless steel fittings.

Fully assembled and ready for installation.

Standard Features

• Stainless steel frame

• Stainless steel pressure vessels

• Pre-filter housing and cartridge, 10" Full-Flow

• Webtrol® multi-stage centrifugal pump

• Automatic inlet valve

• Low-pressure shut-off with automatic restart

• Tank level input

• Pretreatment interlock input

• Adjustable recycle line

• Pre-filter pressure gauges

• Pump discharge pressure gauge (liquid filled)

• Flow meter for product water

• Flow meter for reject water

• Check valve for product water

• Sample valve for product water

• On / off switch

R14-03-BWM System

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature

conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.

Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro® FPMB-BB5-10 melt blown cartridge.

Systems are designed for use with municipal and well water.

Page 7: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

R14 Series Floor Model RO Systems

Top Quality, Attractively Priced,

Fully Assembled RO systems

Five models for flow rates to 10,800 GPD. Select

the features you want to meet your requirements!

R14-06-1131100 System

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature

conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.

Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro® FPMB-BB5-20 melt blown cartridge.

Systems are designed for use with municipal and well water.

Standard Features (Package #1)

• Powder coated steel frame

• Stainless steel pressure vessels

• Pre-filter housing and cartridge (20" Full-Flow)

• Webtrol® heavy-duty multi-stage centrifugal pump

• Automatic inlet valve

• Low-pressure shut-off with automatic restart

• Tank level input

• Pretreatment interlock input

• Adjustable recycle line

• Pre-filter pressure gauges

• Pump discharge pressure gauge (liquid filled)

• Flow meter for product water

• Flow meter for reject water

• Flow meter for recycle water

• Check valve for product water

• On / off switch

Additional Features Included

With Package #2

• CI-1000 electronic controller with product

water conductivity meter and alarm output

• Programmable concentrate auto flush

Page 8: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

R24 Series Commercial RO SystemsThree models and two design options for flow rates up to 15 GPM.

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature

conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.

Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is 20” Full-Flow plastic housing and Flow-Pro®

FPMB-BB5-20 melt blown filter cartridge. Systems are designed for use with municipal and well water

• Powder coated steel frame

• FRP multi-port pressure vessels

• Pre-filter housing and cartridge (20” B-B)

• Webtrol® multi-stage centrifugal pump

• Automatic inlet valve

• Low-pressure shut-off with auto restart

• Tank level input

• Pretreatment interlock input

• Adjustable recycle line

• Pre-filter pressure gauges

• Pump discharge pressure gauge

• Flow meter for product water

• Flow meter for reject water

• Flow meter for recycle water

• Check valve for product water

• Sample valves for product water

• On / off switch

Standard Features (Package #1)

Additional Features Included

With Package #2

• CI-1000 electronic controller with product water

conductivity meter and alarm output.

• Programmable concentrate auto flush.

Page 9: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

����

R44 Series Commercial RO SystemsThree models and two design options for flow rates up to 30 GPM.

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature

conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.

Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Max® FM4X3 filter housing, constructed

using 316 stainless steel and 2" MNPT pipe fittings and Flow-Pro® FPMB5-30 melt blown filter cartridges. Systems are designed for use with

municipal and well water.

• Powder coated steel frame

• FRP multi-port pressure vessels

• Stainless steel pre-filter and cartridges

• Webtrol® multi-stage centrifugal pump

• Automatic inlet valve

• Low-pressure shut-off with auto restart

• Tank level input

• Pretreatment interlock input

• Adjustable recycle line

• Pre-filter pressure gauges

• Pump discharge pressure gauge

• Flow meter for product water

• Flow meter for reject water

• Flow meter for recycle water

• Check valve for product water

• Sample valves for product water

• On / off switch

Standard Features (Package #1)

• CI-1000 electronic controller with product water conductivity meter and alarm output

• Programmable concentrate auto flush

Additional Features Included

With Package #2

Page 10: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

�� �

R48 Series Commercial RO SystemsFour models for flow rates up to 100 GPM.

Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature

conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.

Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Max® FM7x4 filter housing, constructed using

316 stainless steel and 2" MNPT pipe fittings and Flow-Pro® FPMB5-40 melt blown filter cartridges. Systems are designed for use with municipal

and well water.

• Powder coated steel frame

• FRP multi-port pressure vessels

• Stainless steel pre-filter and cartridges

• Webtrol® multi-stage centrifugal pump

• Automatic inlet valve

• Low-pressure shut-off with auto restart

• Tank level input

• Pretreatment interlock input

` • Adjustable recycle line

• Pre-filter pressure gauges

• Pump discharge pressure gauge

• Flow meter for product water

• Flow meter for reject water

• Flow meter for recycle water

• Check valve for product water

• Sample valves for product water

• On / off switch

Standard Features

Additional Features Included R48 Systems

• CI-2000 electronic controller with feed and product water conductivity meter with percent rejection

• Programmable concentrate auto flush

R48-20-3131100

198"x42"x72"

198"x42"x72"

198"x42"x72"

198"x42"x72"

Page 11: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Page 12: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Commercial RO MembranesTop quality membranes for commercial reverse osmosis systems.

Watts® Commercial Membranes

Part Number Application O.D. Length Capacity No. Per

(GPD) Case

W-2521-TW Tap water 2-1/2" 21" 300 1

W-2540-TW Tap water 2-1/2" 40" 800 1

W-4021-TW Tap water 4" 21" 1,050 1

W-4040-TW Tap water 4" 40" 2,200 1

W-4040-BW Brackish water 4" 40" 2,200 1

Note: Watts commercial membranes are packaged in preservatives. Keep in cool environment if stored for prolonged periods of time.

Filmtec® By Dow® Commercial Membranes For Tap Water

Part Number Application O.D. Length Capacity (GPD) No. Per Case

TW30-2514 Tap water 2-1/2" 14" 170 1

TW30-2521 Tap water 2-1/2" 21" 300 1

TW30-2540 Tap water 2-1/2" 40" 660 1

TW30-4014 Tap water 4" 14" 480 1

TW30-4021 Tap water 4" 21" 900 1

TW30-4040 Tap water 4" 40" 2,200 1

Note: Specifications are based on 225 psi pressure and 77°F temperature.

Commercial Membranes For Brackish Water Part Number Application O.D. Length Capacity (GPD) No. Per Case

BW30-2540 Brackish water 2-1/2" 40" 660 1

BW30-4040 Brackish water 4" 40" 2,200 1

BW30-400 Brackish water 8" 40" 10,500 1Note: Brackish water membrane specifications are based on 225 psi pressure and 77°F temperature.

Watts Membrane Specifications

Data W-2521-TW W-2540-TW W-4021-TW W-4040-TW W-4040-BW

Membrane type TFC TFC TFC TFC TFC

Material Polyamide Polyamide Polyamide Polyamide Polyamide

Charge Negative Negative Negative Negative Negative

Configuration Spiral-wound Spiral-wound Sprial-wound Spiral-wound Sprial-wound

Salt rejection 99.5% 99.5% 99.5% 99.5% 99.5%

Max. operating temp. 113°F / 45°C 113°F / 45°C 113°F / 45°C 113°F / 45°C 113°F / 45°C

Max. operating pressure 400 psi 400 psi 400 psi 400 psi 600 psi

Maximum turbidity (NTU) <1 <1 <1 <1 <1

Max. SDI <5 <5 <5 <5 <5

pH range (cleaning) 2-11 2-11 2-11 2-11 2-11

Flux (GPD) 300 800 1,050 2,200 2,200

Note: Tap water membrane specifications are based on 225 psi pressure and 77°F temperature.

Filmtec® By Dow® Commercial Membranes For Sea Water

Part Number Application O.D. Length Capacity (GPD) No. Per Case

SW30-2514 Sea water 2-1/2" 14" 100 1

SW30-2521 Sea water 2-1/2" 21" 200 1

SW30-2540 Sea water 2-1/2" 40" 540 1

SW30-4021 Sea water 4" 21" 600 1

SW30-4040 Sea water 4" 40" 1,500 1

SW30-8040 Sea water 8" 40" 6,000 1

WQP-CAT10-0940

Page 13: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Grundfos® MQ3 Pump

This unique pump is included in the package forre-pressurization. It’s a totally stand alonecomponent, operating independently.

Simply plug it in directly to a 110 volt outletand the pump turns itself on and off andadjusts speed based on flow.

MQ3 pumps are stocked as components.Part Number: R6316-MQ3-45-1.

Atmospheric Tank & Pump Packages

Model Numbers

Ideal for whole house and light commercial installations.

Reduce installation labor with these complete tank and pump packages withcomponents pre-installed to save time and money!

Polyethylene atmosphericstorage tanks with float switchand bulkhead fittings installed.

Pre Installed Float Switch. Junction boxconnects thefloat switch toRO system.

Part Number Tank SizeFloat Switch And

Junction BoxBulkheadFittings

Overflow Pump

R-2288-165 165 gals. Installed Installed Installed Grundfos® MQ3

R2288 300 gals. Installed Installed Installed Grundfos® MQ3

R2288-500 500 gals. Installed Installed Installed Grundfos® MQ3

Custom sizes are available – please call for quotation.

Page 14: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Accessories for Commercial RO SystemsLiquid level controls, pressure switches & metal pressure tanks.

Liquid Level Controls

Float switch used with atmospheric storage tanks

to shut-off system when tank is full.

Part Number Description

L75222 Control with single stage suction and 1/2" NPT PP fittings.

Pressure Switch

Used with bladder pressure tanks

to shut-off system with tank is full.

Part Number Description

U217-2E Switch pre-set 30-60 psi with 1/4" NPT fittings.

Important:

Install level control so the float will hinge

upward (as shown). Not downward.

Watts® Pressure Regulators

Part Number Description

P50-0/25 1/4" Pressure reg 0-25 PSI 4 port

P60 2 port pressure regulator valve

P60-4 Pressure regulator 1/4" 0-125 PSI 4 port

P50-0/25

P60

P60-4

Page 15: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Atmospheric Storage TanksNon-pressure polypropylene.

Tanks designed for 12# liquids or 1.5 specific gravity. Manufactured using FDA approved materials.

Part Number Dia. x Hgt. Gallons Thickness Opening Points Weight

C8005 23X38 65 1/4" 7" Lid / 2" Drain TCIP 26

C8006 23x64 100 1/4" 7" Lid / 2" Drain TCIP 33

C8009 31x58 165 1/4" 8" Lid / 2" Drain TnTCIP 50

C8013 35x81 300 1/4" 16" Lid / 2" Drain TCIP 80

C8017 48x72 500 5/16" 16" Lid / 2" Drain TnTCIP 100

C8029 64x81 1000 3/8" 16" Lid / 2" Drain TnTCIP 365

C8035 86x52 1200 3/8" 16" Lid / 2" Drain TnTCIP 375

C8045 86x74 1700 13/32" 16" Lid / 2" Drain TCIP 340

C8049 87x87 2100 7/16" 16" Lid / 2" Drain TCIP 340

Page 16: SECTION 19 Commercial rO Systemsmedia.wattswater.com/WQCP_CommercialROs.pdfconductivity meter and alarm output. • Programmable concentrate auto flush. Commercial Reverse Osmosis

Commercial Reverse Osmosis Systems

Blue-White®

Flowmeters

Standard Flowmeters For Liquid With 316 SS Guide Rods

Part Number BW Part No. Series GPM Connection Adapter Material Float Material

R5126 F-40375LN-6 F-400N 0.1 to 1.0 3/8” Polypropylene PVC

R5129 F-40376LN-8 F-400N 0.2 to 2.0 1/2” Polypropylene 316 SS

R5138 F-40500LN-8 F-400N 0.5 to 5.0 1/2” Polypropylene 316 SS

R5397 F-451003LHN F-451 3.0 to 30 1” Polysulfone 316 SS

R5398 F-451004LHN F-451 4.0 to 40 1” Polysulfone 316 SS

R5408 F-452060LHN F-452N 6 to 60 2" FNPT Polysulfone 316 SS

R5409 F-452080LHN F-452N 8 to 80 2" FNPT Polysulfone 316 SS

F-400 Series F-440 Series

F-410N Series

F-410N Series F-452 Series