series eda

32
Electronic Pressure Switch The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc

Upload: dwyer-instruments-inc

Post on 30-May-2015

443 views

Category:

Business


2 download

TRANSCRIPT

Page 1: Series EDA

Electronic Pressure Switch

The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included

within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc

Page 2: Series EDA

EDA SeriesElectronic Pressure Gage, Switch & Transmitter

Local Pressure Indication2 Independent Switches

ControlAlarm

Analog transmission

Page 3: Series EDA

ApplicationsReplaces Mercoid DA pressure switchExamples:

Booster PumpsFire Pump ControlTank Level ControlSafety pressure switch

Manual ResetBubbler SystemsElevated Water Storage TankAir Compressors

Page 4: Series EDA

SpecificationsService: Compatible liquids and gases316SS wetted materialsAccuracy: ±1% of F.S. Power Requirements: 12 to 30 VDC/ACEnclosure Rating: IP65Optional Output Signals2 SPDT Switches

Switch Reset: Manual or Automatic

Page 5: Series EDA

Model Chart

Page 6: Series EDA

EDA Advantages

No Separate Calibrator Required

On screen programming6 button operationLocal LED Status Lights

Page 7: Series EDA

EDA Advantages

3 Settings for Relay Control1 Control Relay1 Control Relay, 1 Alarm Relay2 Control Relay

Independent set point adjustmentDeadband AdjustmentDuplex & Alternation control

Page 8: Series EDA

EDA Advantages

Metric & US Based Engineering UnitsIn Field CalibrationFlush Panel, Surface or Pipe MountableUL Approved

Page 9: Series EDA

Easier Installation

Page 10: Series EDA

Scalable OutputTransmitter Scaling Example

Base range 0-7 barOn-Screen programming

Output could be configured to any range within base range:

0-5 bar0-2 bar0-1 bar1-6 bar2-7 bar , etc

Page 11: Series EDA

Wiring

Page 12: Series EDA

Front Face

Page 13: Series EDA

Menu GuideSetpoint/Alarm Menu

       

       

      Set Point High

       

       

       

      Set Point Low

       

       

Page 14: Series EDA

Menu GuideSetpoint/Alarm Menu

Set Point High 1        

         

Set Point Low 1      

Set Point High 2

         

         

         

       Set Point Low 2

Page 15: Series EDA

Menu GuideSetpoint/Alarm Menu

Alarm High        

         

       Set Point

High 2

         

         

         

       Set Point

Low 2

Alarm Low        

         

Page 16: Series EDA

Base MenusSecurity

Lock out access to settings

Operation Pressure units, zero, and back light

Output Relay Modes, alternating function, time delay, and lamp indication

Page 17: Series EDA

Base Menus

Display Monitor and adjust display related settings: Peak, Valley and Dampening

AdvancedSimulate transmitter scaling, factory default, and calibration

Page 18: Series EDA

Base Menus

Test Simulate pressure input

Fail SafeSelect Fail Safe Mode

Page 19: Series EDA

Menu Guide

Page 20: Series EDA

EDAUnit Selection

Press Menu Press DOWN

until “OPER” appears

Page 21: Series EDA

Unit Selection

Press ENTER

Press ENTER Using

UP/DOWN select units, then press ENTER to save

Page 22: Series EDA

Unit Selection

Press MENU to return

Page 23: Series EDA

EDA Output & Setpoint Selection

Page 24: Series EDA

EDA Control & Setpoint Selection

Press DOWN until “OUT” appears, then press ENTER

Press ENTER

Page 25: Series EDA

EDAControl & Setpoint Selection

Press ENTER Press

UP/DOWN to select “SPAL” mode

Press ENTER to save

Press MENU to return

Page 26: Series EDA

EDA Control & Setpoint Selection

Press SP/AL Press ENTER, then use UP/Down to adjust setpoint, then ENTER

Press ENTER, then use UP/Down to adjust setpoint, then ENTER

Page 27: Series EDA

EDAControl & Setpoint Selection

Press ENTER, then use UP/Down to adjust setpoint, then ENTER

Press MENU to show pressure reading

Page 28: Series EDA

Menu Guide

Page 29: Series EDA

EDAControl & Setpoint Selection

Press Menu Press DOWN

until “ADV” appears

Page 30: Series EDA

EDATransmitter Output Scaling

Press ENTER

Use UP/DOWN to select 4mA value, then Press ENTER & DOWN

Use UP/DOWN to select 20mA value, then Press ENTER & MENU

Page 31: Series EDA

EDATransmitter Output Scaling

Press MENU

Page 32: Series EDA

Questions

To order a free catalog or for more information contact;Dwyer Instruments, Inc., P.O. Box 373,

Michigan City, IN., 46361Telephone: (800) 872-9141 or (219) 879-8000

Fax: (219) 872-9057Internet address: www.dwyer-inst.com