service and solutions through engineering · vd/ts is a combination pressure/ vacuum conservation...

2
PROTEGO ® VD/TS Spending too much time and money on tank vent maintenance? PROTEGO ® VD/TS Combination Pressure/Vacuum Vent with integrated Flame Arrester can minimize down time. Regular Flame Arrester Inspection with zero down time for safety and environment Challenge Manpower reduction means less available time for proper maintenance and inspection of tank safety equipment. Many manufacturers´ p/v-vent with flame arresters are not „maintenance friendly“ and it becomes a time consu- ming task just to perform an inspection. In many cases, two people are required to remove the p/v-vent so that the flame arrester can be inspected. Sometimes a crane is required for removal of the conservation vent to allow access to the flame arrester. Solution The PROTEGO ® VD/TS is a combination pressure/ vacuum conservation vent with integrated flame ar- rester in one compact unit. The 0.4“ thick FLAME FILTER ® disc can be easily inspected „in-place“, by simply removing the side mounted weather hood. Be- cause the FLAME FILTER ® is only exposed to tank vapors while the tank is out-breathing, the likelihood of clogging is significantly reduced. The typical manuf- acturers´ arrangement results in tank vapor contact with the flame filter 100% of the time, therefore, increasing clogging potential and frequency of required maintenance.

Upload: others

Post on 11-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Service and Solutions through Engineering · VD/TS is a combination pressure/ vacuum conservation vent with integrated flame ar-rester in one compact unit. The 0.4“ thick FLAME

PROTEGO® VD/TS

Spending too much time and money on tank vent maintenance? PROTEGO® VD/TS Combination Pressure/Vacuum Vent with integrated Flame Arrester can minimize down time.

Regular Flame Arrester Inspection with zero down time

for safety and environment

ChallengeManpower reduction means less available time for proper maintenance and inspection of tank safety equipment. Many manufacturers´ p/v-vent with flame arresters are not „maintenance friendly“ and it becomes a time consu-ming task just to perform an inspection. In many cases, two people are required to remove the p/v-vent so that the flame arrester can be inspected. Sometimes a crane is required for removal of the conservation vent to allow access to the flame arrester.

SolutionThe PROTEGO® VD/TS is a combination pressure/vacuum conservation vent with integrated flame ar-rester in one compact unit. The 0.4“ thick FLAME FILTER® disc can be easily inspected „in-place“, by simply removing the side mounted weather hood. Be-cause the FLAME FILTER® is only exposed to tank vapors while the tank is out-breathing, the likelihood of clogging is significantly reduced. The typical manuf-acturers´ arrangement results in tank vapor contact with the flame filter 100% of the time, therefore, increasing clogging potential and frequency of required maintenance.

Page 2: Service and Solutions through Engineering · VD/TS is a combination pressure/ vacuum conservation vent with integrated flame ar-rester in one compact unit. The 0.4“ thick FLAME

Additional BenefitThe PROTEGO® p/v-vent only requires 10% overpressure above the pressure setpoint for the weight-loaded pallet to fully open. The typical weight-loaded pallet conservation vent requires 80 -100% overpressure above the pressure setpoint to reach full lift. By using the 10% overpressure technology according to API 2000 higher vent pressure set-points can be used compared to an 80% or 100% overpressure vent, resulting in reduced emissions and vapor loss according to API 2521.

PROTEGO® VD/TS: easy to maintain and price competitive

Service and Solutions through Engineering

PROTEGO® Head Office Braunschweiger Flammenfilter GmbH Industriestrasse 11 38110 Braunschweig phone: +49 (0) 5307 / 809-0 fax: +49 (0) 5307 / 78 24 e-mail: [email protected]

www.protego.com

for safety and environment

PR

OTE

GO

®, F

LAM

EFI

LTE

R® a

nd F

LAM

ME

NFI

LTE

R® a

re re

gist

ered

trad

emar

ks o

f B

raun

schw

eige

r Fla

mm

enfil

ter G

mbH

. p_v

dts_

h_06

2015

_gb

p/v vent

flame arrester

typical competitors´ arrangements: difficult to maintain

p/v vent

integratedflame arrester