shah faisal shah cv

5
Permanent Address: House # 10-B PAEC Chashlam Colony Chashma Barrage Mianwali,, Pakistan. Cell: +92-3008871670 E-mail: [email protected] DOB: 22/07/1988 Skype ID: faisal.engineer0 NIC: 38303-6981353-1 PEC #: ELECT/43635 Passport#: DJ5153531 CAREER OBJECTIVE I am now looking to build on my extensive range of technical skills within a suitably challenging role. I am keen to achieve further professional development. SUMMARY OF QUALIFICATIONS Skilled and dedicated proficient offering an impressive 3-year leadership background in multinational and National level companies with an exceptional understanding of management strategies and technical environments. Provide comprehensive direction and solutions. Fluent in Urdu and English. Areas of Expertise 220/132/11kV Grid Station Protection & Instrumentation Electrical Engineer Protection & Maintenance 84 MW Power House, July 2014---Present Madina Group of Industries Faisalabad, (MGI) Madina Group of Industries has 184 MW Power House Protection & Instrumentation of 33/11kV Grid Station. Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of Transformer, circuit breaker, isolator, Current transformer, and Potential transformer. Analyze and prepare the fault reports. Efforts to minimize the breakdowns and minimize the breakdown time. Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT), Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits. Annual Maintenance and testing of 33/11kV, 160MVA Auto Transformers. Test conducts are Transformer Turns Ratio, Capacitance & Dissipation Factor (C&DF), Insulation Resistance Test, DES, Differential Balancing, Open Circuit, Short Circuit Engr.Shah Faisal Shah Protection & Maintenance of 220/132/11kV Grid Station Utility Maintenance & Operation Management New Utility Project Management Erection & Commissioning of Equipment Power Plant Maintenance & Operation

Upload: shah-faisal-shah

Post on 14-Apr-2017

168 views

Category:

Engineering


19 download

TRANSCRIPT

Page 1: Shah faisal shah cv

Permanent Address: House # 10-B PAEC Chashlam Colony Chashma Barrage Mianwali,, Pakistan.Cell: +92-3008871670 E-mail: [email protected]: 22/07/1988 Skype ID: faisal.engineer0NIC: 38303-6981353-1 PEC #: ELECT/43635Passport#: DJ5153531

CAREER OBJECTIVE I am now looking to build on my extensive range of technical skills within a suitably challenging role. I am

keen to achieve further professional development.

SUMMARY OF QUALIFICATIONS Skilled and dedicated proficient offering an impressive 3-year leadership background in multinational and

National level companies with an exceptional understanding of management strategies and technical environments. Provide comprehensive direction and solutions. Fluent in Urdu and English.

Areas of Expertise 220/132/11kV Grid Station Protection & Instrumentation

Electrical Engineer Protection & Maintenance84 MW Power House, July 2014---PresentMadina Group of Industries Faisalabad, (MGI) Madina Group of Industries has 184 MW Power House

Protection & Instrumentation of 33/11kV Grid Station. Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of

Transformer, circuit breaker, isolator, Current transformer, and Potential transformer. Analyze and prepare the fault reports. Efforts to minimize the breakdowns and minimize the breakdown time. Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer

protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT), Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.

Annual Maintenance and testing of 33/11kV, 160MVA Auto Transformers. Test conducts are Transformer Turns Ratio, Capacitance & Dissipation Factor (C&DF), Insulation Resistance Test, DES, Differential Balancing, Open Circuit, Short Circuit

Annual Maintenance and testing of 33kV Circuit breakers. Test Conducts are: Contact Resistance Test, Breaker Timing Test etc.

Testing, configuration and communication of Relays like Numerical relays/digital relays/static relays/electromechanical relays (ABB, AREVA, SIEMENS, and GE).

Annual testing of all Protective Relays including Overcurrent (CDG, MCGG, ABB SPAJ 140C, Siemens Siprotec 7SJ6005, GE Multiline MIFII), Differential Relays (DTH, D2e, 7UT612, RADSB), Distance Relay (L3wys,LZ-96a,REL521), Restricted Earth Fault Relay, Breaker Failure, Under Frequency, Over fluxing etc

Testing of all mechanical Relays (Bucholz, Temperature gauges, Pressure Relieve Device (PRD)) Erection, Installation & commissioning of Transformers, breakers and all Grid Station related equipments. Hands on Experience of Testing kits: Severker 780, Freja 300, Freja 306, ZFB, QZW, Megger, CT Analyzer,

Breaker Analyzer TM-1600, MOM600, Primary Injection ODEN At, CB-100 etc

Trainee Engineer Electrical; Operation, Maintenance Electrical & New Projects InstallationChashma Nuclear Power Plant3, 4, Chashma Plant-Pakistan December 2013 --- June 2014

Engr.Shah Faisal Shah

Protection & Maintenance of 220/132/11kV Grid Station Utility Maintenance & Operation Management New Utility Project Management

Erection & Commissioning of Equipment Power Plant Maintenance & Operation Drawing & Layouts of Projects

Page 2: Shah faisal shah cv

Chashma Nuclear Power Plant is consist of 4 Plants Chashma1, Chashma2, Chashma3, and Chashma4. Capacity of C1 is 325MW, C2 is 340MW, C3 is 340MW, and C4 is 340MW. It has four outgoing lines 1 is wanbachran, 2 is Ludawala, 1 is daweed khail.

Protection & Instrumentation of 220/132/11/6.6kV GIS Grid Station. Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of

Transformer, circuit breaker, isolator, Current transformer, and Potential transformer. Analyze and prepare the fault reports. Efforts to minimize the breakdowns and minimize the breakdown time. Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer

protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT), Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.

Annual Maintenance and testing of 220/132kV, 370MVA Auto Transformers. Test conducts are Transformer Turns Ratio, Capacitance & Dissipation Factor (C&DF), Insulation Resistance Test, DES, Differential Balancing, Open Circuit, Short Circuit

Annual Maintenance and testing of 220kV SF6 Circuit breakers. Test Conducts are: Contact Resistance Test, Breaker Timing Test, SF6 Purity & Due Point Test etc.

Testing, configuration and communication of Relays like Numerical relays/digital relays/static relays/electromechanical relays (ABB, AREVA, SIEMENS, GE).

Annual testing of all Protective Relays including Overcurrent (CDG, MCGG, ABB SPAJ 140C, Siemens Siprotec 7SJ6005, GE Multiline MIFII), Differential Relays (DTH, D2e, 7UT612, RADSB), Distance Relay (L3wys,LZ-96a,REL521), Restricted Earth Fault Relay, Breaker Failure, Under Frequency, Over fluxing etc

Testing of all mechanical Relays (Bucholz, Temperature gauges, Pressure Relieve Device (PRD)) Erection, Installation & commissioning of Transformers, breakers and all Grid Station related equipments. Hands on Experience of Testing kits: Severker 780, Freja 300, Freja 306, ZFB, QZW, Megger, CT Analyzer,

Breaker Analyzer TM-1600, MOM600, Primary Injection ODEN At, CB-100 etc

Trainee Engineer; Operation & Maintenance ElectricalHydel Power Plant Chahsma Barrage– Pakistan August 2010 --- October 2010

Chashma Hydel power Plant is Located in Punjab on Indus River at Chashma Barrage Mianwali. It Has Total 8 Units Each Unit having 23MW Capacity his total capacity is 184 MW. Total 4 transmission lines of 220Kv, 2 line Ludawala1 & Ludawala2 2 lines are D I Khan 1&2.

Protection & Instrumentation of 220/132/11/6.6kV Grid Station. Perform Maintenance Management like Preventive, Corrective, Predictive and Daily maintenance of

Transformer, circuit breaker, isolator, Current transformer, and Potential transformer. Analyze and prepare the fault reports. Efforts to minimize the breakdowns and minimize the breakdown time. Work on protection of Electrical Power system like Line protection, Bus Bar protection, Transformer

protection, breakers protection, Battery Charger, Batteries Maintenance, Current transformer (CT), Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.

Testing, configuration and communication of Relays like Numerical relays/digital relays/static relays/electromechanical relays (ABB, AREVA, SIEMENS, and GE).

Testing of all mechanical Relays (Bucholz, Temperature gauges, Pressure Relieve Device (PRD)) Erection, Installation & commissioning of Transformers, breakers and all Grid Station related equipments. Hands on Experience of Testing kits: Severker 780, Freja 300, Freja 306, ZFB, QZW, Megger, CT Analyzer,

Breaker Analyzer TM-1600, MOM600, Primary Injection ODEN At, CB-100 etc

TRAINING AND CERTIFICATES

Certificate of Participation in IEEE – Orientation & Career Development ( Held on 22nd April, 2013at S.C.E.T RYK)

Certificate of Participation in Annual Student Technology and Engineering Competition – 2013 ( Held on 03rd May, 2013 at S.C.E.T RYK)

2nd Position in Final Project Proposal Presentation by (18/20) Marks

Page 3: Shah faisal shah cv

Best Footballer Award in Swedish Cricket Premier League (Shield +Certificate) 1 Week training on Numerical Relays from Technical Services Group () Plant Maintenance Training at Pakistan Society For Training & Development Middle Management and Core Development. CKD training on pneumatic system and application. 1 week training on telecommunication system from ZTE.

EDUCATION

Islamia University Bahawalpur B.Sc Electrical Engineering – Specialization on Power (73%)(3.23) NOV 2013

PEC # ELECT/ 43635Safia Poly Technical Institute Mianwali

DAE Diploma of Associate Engineer Electrical August 2009Percentage (69%)

PAEC Model College for Boyes Chashma Mianwali Matriculation - Major in Math, Physics and Chemistry July 2006

Percentage (50%)

FINAL YEAR PROJECT

Final Project: Economical Load Scheduling Of Thermal Power Plants In Pakistan (Thesis Report)

6th semester Mini Project : Hydro Power Plant (Working Model + Thesis Report)

2 Months Computer Applications Training (Windows + MS Office)

2 Months Typing & Composing Training (Urdu + English Composing)

COMPUTER SKILL

Computer Application MS Office: World, Excel, Power Point.

Engineering Graphics Engineering Graphics: Auto CAD (2D & 3D),(Knowledge) Matlab C++

Field Technical Software DIGSI ENERVISTA PSW

REFRENCES

Additional information and references can be furnished on request.