siemens setup manuals

858
Siemens Setup Manuals

Upload: api-26892848

Post on 10-Apr-2015

1.612 views

Category:

Documents


8 download

TRANSCRIPT

Page 1: Siemens Setup Manuals

Siemens

Setup Manuals

Page 2: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup Siemens C-arm Arcadis Varic Orbic with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ............................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 3: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens Arcadis Varic via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrfCorr16b-bspline, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=4

Kodak DryView 8300

DICOM Network

Siemens C-armArcadis Varicsyngo platform

Page 4: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens Arcadis Varic via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Arcadis Varic syngo platform VB10B Requirements: 190 rel. 1.7.29 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrfCorr16b-bspline, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape= 0.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraSiemens C-armArcadis Varicsyngo platform

Page 5: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Arcadis Varic via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Arcadis Varic syngo platform VB10B Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrfCorr16b-bspline, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers:

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Siemens C-armArcadis Varicsyngo platform

Page 6: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Printer=8700, AE Title=9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 7: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Arcadis Varic via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: 9410 v1.6, 8100 v2.4.1 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrfCorr16b-bspline, Max Density=3.00

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Siemens C-armArcadis Varicsyngo platform

Page 8: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 9: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Arcadis Varic via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrfCorr16b-bspline, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=1, TFT/ULUT=wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Siemens C-armArcadis Varicsyngo platform

Page 10: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 11: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM200 v6.1, KELI 160 v7.2 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name= k160, Host Sel.= k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=eg Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak 160 cameraSiemens C-armArcadis Varicsyngo platform

Page 12: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0.0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= No Magnif, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 13: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM200 v6.1, 2180 v2.17H Syngo setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Siemens C-armArcadis Varicsyngo platform

Page 14: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0.0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 15: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM200 v6.1, 1120 v2.40/032 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=eg Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Siemens C-armArcadis Varicsyngo platform

Page 16: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0.0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 17: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM 200 v6.1, DV8200 v3.5 Syngo setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name= k8200, Host Sel.= k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device= k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node= k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=eg Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Siemens C-armArcadis Varicsyngo platform

Page 18: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 19: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Siemens C-armArcadis Varicsyngo platform

Page 20: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)= 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 21: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM200 v6.1, 8100 v2.4.1 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Siemens C-armArcadis Varicsyngo platform

Page 22: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 23: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Arcadis Varic via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrfCorr16b-bspline, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Siemens C-armArcadis Varicsyngo platform

Page 24: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= wrkstn83a.w8u (Always=Y), Contrast (dry)=1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 25: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Arcadis Varic via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrfCorr16b-bspline, Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

DICOM Network

Kodak DryView 8900

Siemens C-armArcadis Varicsyngo platform

Page 26: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast=2 (Always=Y) n Smoothing Type=0 (Always=Y), Image Polarity=Normal (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=carm

Page 27: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Arcadis Varic via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Arcadis Varic syngo platform VB10B Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrfCorr16b-bspline, Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On

DICOM Network

Kodak DryView 8150

Siemens C-armArcadis Varicsyngo platform

Page 28: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Wrkstn2a.w87 (Always=Y) n Contrast=1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=carm

Page 29: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Arcadis Varic via DICOM with Kodak Color Medical Imager 1000

Requirements: Arcadis syngo platform VB11A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrfCorr16b-bspline, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

DICOM Network

Kodak CMI 1000

Siemens C-armArcadis - Varic- Orbicsyngo platform

Page 30: Siemens Setup Manuals

Siemens C-arm Arcadis Varic Orbic with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Contrast=7 (Always=Y) n TFT Set (From list)=Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 31: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 10 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 17 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5) ............................................................... 23 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ............ 26 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 29 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 32 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 35 n Kodak DryView 8900 LASER IMAGER......................................................................... 38 n Kodak DryView 8150 LASER IMAGER......................................................................... 41 n Kodak Color Medical Imager 1000 ................................................................................. 44

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 32: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siremobil Compact / ISO-C via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8300

DICOM Network

Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8300; Destination alias name AE_TITLE = K8300 HOST_NAME = e.g., DV8300; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 104 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM; Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 8INX10IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 0; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity

Page 33: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

- into file C:\bridge\hosts set: the-8300-IPaddress DV8300 - into file C:\bridge\Mergecom.app set: [DRYVIEW_8300] PORT_NUMBER=104 HOST_NAME=IP address of 8300 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=4, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set:

n Modality Group=2

Page 34: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siremobil Compact / ISO-C rel. VA00A, 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8500; Destination alias name AE_TITLE = 9410 HOST_NAME = e.g., PACSL_85; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 1024 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM; Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 11INX14IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type 2010,0100 BLACK; Border Density

Page 35: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-9410-IPaddress PACSL_85 - into file C:\bridge\Mergecom.app set: [DRYVIEW_8500] PORT_NUMBER=1024 HOST_NAME=IP address of 9410 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=15, TFT/ULUT=Siefl87b.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 36: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siremobil Compact / ISO-C rel. VA00A, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8700; Destination alias name AE_TITLE = 9410 HOST_NAME = e.g., PACSL_87; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 1024 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type 2010,0100 BLACK; Border Density

Page 37: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-9410-IPaddress PACSL_87 - into file C:\bridge\Mergecom.app set: [DRYVIEW_8700] PORT_NUMBER=1024 HOST_NAME=IP address of 9410 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=15, TFT/ULUT=Siefl87b.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 38: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siremobil Compact / ISO-C rel. VA00A, 9410 v1.6, 8100 v2.4.1 Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8100; Destination alias name AE_TITLE = 9410 HOST_NAME = e.g., PACSL_81; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 1024 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim

Page 39: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-9410-IPaddress PACSL_81 - into file C:\bridge\Mergecom.app set: [DRYVIEW_8100] PORT_NUMBER=1024 HOST_NAME=IP address of 9410 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=15, TFT/ULUT=Siefl87b.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 40: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8300; Destination alias name AE_TITLE = 9410 HOST_NAME = e.g., PACSL_83; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 1024 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 8INX10IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 0; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim

Page 41: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-9410-IPaddress PACSL_83 - into file C:\bridge\Mergecom.app set: [DRYVIEW_8300] PORT_NUMBER=1024 HOST_NAME=IP address of 9410 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8300, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=4, TFT/ULUT=693c0.w8u n Max.Density=300, Border=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 42: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siremobil Compact / ISO-C via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens C-armSiremobil CompactDICOM-bridge

DICOM Network

Kodak 190 camera

Requirements: Siremobil Compact / ISO-C rel. VA00A, 190 rel. 1.7.29 Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = KODAK_190; Destination alias name AE_TITLE = K190 HOST_NAME = e.g., MLP190; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 NORMAL; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity

Page 43: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

- into file C:\bridge\hosts set: the-190-IPaddress MLP190 - into file C:\bridge\Mergecom.app set: [KODAK_190] PORT_NUMBER=5040 HOST_NAME=IP address of 190 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=MLP190, Connection Type=RJ45

Page 44: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: MIM200 v6.1, KELI 160 v7.2 Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = KODAK_160; Destination alias name AE_TITLE = K160 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 NORMAL; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density

Page 45: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [KODAK_160] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

Page 46: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=4 i.e., 575 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 47: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens C-armSiremobil CompactDICOM-bridge

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200 Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = KODAK_2180; Destination alias name AE_TITLE = K2180 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 NORMAL; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density

Page 48: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [KODAK_2180] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

Page 49: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=4 i.e., 575 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 50: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens C-armSiremobil CompactDICOM-bridge

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200 Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = KODAK_1120; Destination alias name AE_TITLE = K1120 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 NORMAL; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density

Page 51: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [KODAK_1120] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

Page 52: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=4 i.e., 575 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 53: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8200; Destination alias name AE_TITLE = K8200 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density

Page 54: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [DRYVIEW_8200] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y)

Page 55: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 56: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8500 Plus

Kodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siremobil Compact / ISO-C rel. VA00A, MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8500; Destination alias name AE_TITLE = K8500 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM; Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 11INX14IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type

Page 57: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [DRYVIEW_8500] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

Page 58: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=11INx14IN (Always=N), Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 59: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8700 Plus

Kodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siremobil Compact / ISO-C rel. VA00A, MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8700; Destination alias name AE_TITLE = K8700 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type

Page 60: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim 2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [DRYVIEW_8700] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N)

Page 61: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 62: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siremobil Compact / ISO-C rel. VA00A, MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer

Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed

Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8100; Destination alias name AE_TITLE = K8100 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 14INX17IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 2; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim

Page 63: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [DRYVIEW_8100] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N)

Page 64: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 65: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

Siremobil Compact / ISO-C via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens C-armSiremobil CompactDICOM-bridge

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siremobil Compact / ISO-C rel. VA00A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer

Note: on Siremobil Compact / ISO-C only a DICOM camera could be installed

Siremobil Compact / ISO-C Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8300; Destination alias name AE_TITLE = K8300 HOST_NAME = e.g., MIM; Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED; Print Priority 2000,0030 BLUE_FILM;Medium Type 2000,0040 PROCESSOR; Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT; Film Session Label 2010,0040 PORTRAIT; Film Orientation 2010,0050 8INX10IN; Film Size 2010,0060 CUBIC; Magnification Type 2010,0080 0; Smoothing Type 2010,0100 BLACK; Border Density 2010,0110 BLACK; Empty Image Density 2010,0130 300; Max density 2010,0140 NO; Trim

Page 66: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

2020,0020 NORMAL; Polarity - into file C:\bridge\hosts set: the-MIM200-IPaddress MIM - into file C:\bridge\Mergecom.app set: [DRYVIEW_8300] PORT_NUMBER=5040 HOST_NAME=IP address of MIM200 SERVICE_LIST=Print_Service_List - reboot the DICOM Bridge computer MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=693c0.w8u (Always=Y), Contrast (dry)=4 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N)

Page 67: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 68: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Siremobil Compact / ISO-C via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Siremobil Compact rel. VA00A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on Siremobil Compact only a DICOM camera could be installed Siremobil Compact Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8900 ;Destination alias name AE_TITLE = K8900 HOST_NAME = eg DV8900 ;Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED ;Print Priority 2000,0030 BLUE_FILM ;Medium Type 2000,0040 PROCESSOR ;Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT ;Film Session Label 2010,0040 PORTRAIT ;Film Orientation 2010,0050 14INX17IN ;Film Size 2010,0060 CUBIC ;Magnification Type 2010,0080 2 ;Smoothing Type 2010,0100 BLACK ;Border Density 2010,0110 BLACK ;Empty Image Density 2010,0130 300 ;Max density 2010,0140 NO ;Trim 2020,0020 NORMAL ;Polarity

Siemens C-armSiremobil CompactDICOM-bridge

DICOM Network

Kodak DryView 8900

Page 69: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

- into file C:\bridge\hosts set: the-8900-IPaddress DV8900 - into file C:\bridge\Mergecom.app set: [DRYVIEW_8900] PORT_NUMBER=5040 HOST_NAME= IP address of 8900 SERVICE_LIST= Print_Service_List - reboot the DICOM Bridge computer 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Siefl87b.w87 (Always=Y) n Contrast= 15 (Always=Y), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=carm

Page 70: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Siremobil Compact / ISO-C via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Siremobil Compact rel. VA00A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: on Siremobil Compact only a DICOM camera could be installed Siremobil Compact Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = DRYVIEW_8150 ;Destination alias name AE_TITLE = DV8150 HOST_NAME = eg MIM ;Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 STANDARD\3,3 STANDARD\4,5 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED ;Print Priority 2000,0030 BLUE_FILM ;Medium Type 2000,0040 PROCESSOR ;Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT ;Film Session Label 2010,0040 PORTRAIT ;Film Orientation 2010,0050 14INX17IN ;Film Size 2010,0060 CUBIC ;Magnification Type 2010,0080 2 ;Smoothing Type 2010,0100 BLACK ;Border Density 2010,0110 BLACK ;Empty Image Density 2010,0130 300 ;Max density 2010,0140 NO ;Trim 2020,0020 NORMAL ;Polarity

Siemens C-armSiremobil CompactDICOM-bridge

DICOM Network

Kodak DryView 8150

Page 71: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

- into file C:\bridge\hosts set: the-8150-IPaddress MIM - into file C:\bridge\Mergecom.app set: [DRYVIEW_8150] PORT_NUMBER=5040 HOST_NAME= IP address of 81500 SERVICE_LIST= Print_Service_List - reboot the DICOM Bridge computer 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name= Siefl87b.w87 (Always=Y) n Contrast=15 (Always=Y), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=carm

Page 72: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Siremobil Compact / ISO-C via DICOM with Kodak Color Medical Imager 1000

Requirements: Siremobil Compact rel. VA00A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on Siremobil Compact only a DICOM camera could be installed Siremobil Compact Setup: - into file C:\bridge\bridge.cfg set: [PRINT_NODE_1] DESCRIPTION = CMI_1000 ;Destination alias name AE_TITLE =CMI1000 HOST_NAME = eg CMI1000 ;Destination machine name IP_ADDRESS = accordingly PORT_NUM = 5040 FILM_FORMAT = STANDARD\1,1 STANDARD\2,2 STANDARD\2,3 NUMBER_COPIES = 1 MAX_NUMBER_COPIES = 10 COLLATION = DISABLED ASPECT_RATIO_CORRECTION = DISABLED ASPECT_RATIO_INTERPOLATION = REPLICATE 2000,0020 MED ;Print Priority 2000,0030 BLUE_FILM ;Medium Type 2000,0040 PROCESSOR ;Film Destination 2000,0050 SIEMENS_SIREMOBIL_COMPACT ;Film Session Label 2010,0040 PORTRAIT ;Film Orientation 2010,0050 8INX10IN ;Film Size 2010,0060 CUBIC ;Magnification Type 2010,0080 2 ;Smoothing Type 2010,0100 BLACK ;Border Density 2010,0110 BLACK ;Empty Image Density 2010,0130 300 ;Max density 2010,0140 NO ;Trim 2020,0020 NORMAL ;Polarity - into file C:\bridge\hosts set: the-CMI1000-IPaddress CMI1000

DICOM Network

Kodak CMI 1000

Siemens C-armSiremobil CompactDICOM-bridge

Page 73: Siemens Setup Manuals

Siemens C-arm Siremobil Compact / ISO-C with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

- into file C:\bridge\Mergecom.app set: [CMI_1000] PORT_NUMBER=5040 HOST_NAME= IP address of CMI1000 SERVICE_LIST= Print_Service_List - reboot the DICOM Bridge computer CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=15 (Always=Y) n TFT Set (From list)=Siefl87b.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 74: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup Siemens C-arm Siremobil ISO-C 3D with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ............................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 75: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens Siremobil ISO-C 3D via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrf (or xrf_16bin), Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=4

Kodak DryView 8300

DICOM Network

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 76: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens Siremobil ISO-C 3D via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 190 rel. 1.7.29 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrf (or xrf_16bin), Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape= 0.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraSiemens C-armSiremobil ISO-C 3Dsyngo platform

Page 77: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrf (or xrf_16bin), Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers:

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 78: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Printer=8700, AE Title=9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 79: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 9410 v1.6, 8100 v2.4.1 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrf (or xrf_16bin), Max Density=3.00

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 80: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 81: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrf (or xrf_16bin), Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=1, TFT/ULUT=wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 82: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 83: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM200 v6.1, KELI 160 v7.2 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name= k160, Host Sel.= k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=eg Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak 160 cameraSiemens C-armSiremobil ISO-C 3Dsyngo platform

Page 84: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0.0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= No Magnif, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 85: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM200 v6.1, 2180 v2.17H Syngo setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 86: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0.0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 87: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM200 v6.1, 1120 v2.40/032 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=eg Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 88: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0.0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 89: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM 200 v6.1, DV8200 v3.5 Syngo setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name= k8200, Host Sel.= k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device= k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node= k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=eg Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set : XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 90: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 91: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 92: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)= 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 93: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM200 v6.1, 8100 v2.4.1 syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 94: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 95: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Siremobil ISO-C 3D via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set: XRF Image= xrf (or xrf_16bin), Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 96: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= wrkstn83a.w8u (Always=Y), Contrast (dry)=1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 97: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Siremobil ISO-C 3D via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf (or xrf_16bin), Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

DICOM Network

Kodak DryView 8900

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 98: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast=2 (Always=Y) n Smoothing Type=0 (Always=Y), Image Polarity=Normal (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=carm

Page 99: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Siremobil ISO-C 3D via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf (or xrf_16bin), Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On

DICOM Network

Kodak DryView 8150

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 100: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Wrkstn2a.w87 (Always=Y) n Contrast=1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=carm

Page 101: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Siremobil ISO-C 3D via DICOM with Kodak Color Medical Imager 1000

Requirements: Siremobil ISO-C 3D syngo platform and 3D sw version VC00B Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf (or xrf_16bin), Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

DICOM Network

Kodak CMI 1000

Siemens C-armSiremobil ISO-C 3Dsyngo platform

Page 102: Siemens Setup Manuals

Siemens C-arm Siremobil ISO-C 3D with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Contrast=7 (Always=Y) n TFT Set (From list)=Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 103: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens C-arm Uroskop Access with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ............................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 104: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Uroskop Access via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak DryView 8300

DICOM Network

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=4

Page 105: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Uroskop Access via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens Uroskope AccessASPIA platform

DICOM Network

Kodak 190 camera

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 190 rel. 1.7.29 Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XRF Image=xrf, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=0.0, Contrast=0 n Contrast Pivot Density=1.2, IPAddress=accordingly n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 106: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Uroskop Access via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens Uroskope AccessASPIA platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers:

Page 107: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Printer=8700, AE Title=9410, Port=1024, Max Associations=5 on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 108: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Uroskop Access via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 9410 v1.6, 8100 v2.4.1 Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=1, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0

Page 109: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 110: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Uroskop Access via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=1, TFT/ULUT=wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1

Page 111: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 112: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Page 113: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnification n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 114: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens Uroskope AccessASPIA platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, 2180 v2.17H Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 115: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnification n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 116: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens Uroskope AccessASPIA platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, 1120 v2.40/032 Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 117: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnification n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 118: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On

Page 119: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 120: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens Uroskope AccessASPIA platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700

Page 121: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 122: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 123: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=Y) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 124: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Uroskop Access via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens Uroskope AccessASPIA platform

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo configured Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XRF Image=xrf, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 125: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=wkstn83a.w8u (Always=Y), Contrast (dry)=1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 126: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Uroskop Access via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf, Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

Siemens Uroskope AccessASPIA platform

DICOM Network

Kodak DryView 8900

Page 127: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Wrkstn2a.w87 (Always=Y) n Contrast= 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=urosk

Page 128: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Uroskop Access via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf, Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On

Siemens Uroskop AccessASPIA platform

DICOM Network

Kodak DryView 8150

Page 129: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Wrkstn2a.w87 (Always=Y) n Contrast=1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=urosk

Page 130: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Uroskop Access via DICOM with Kodak Color Medical Imager 1000

Requirements: Uroskop Access platform ASPIA rel. VA13A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Image Data lutted by syngo, linear-in-Density LUT into Camera syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set XRF Image= xrf, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

DICOM Network

Kodak CMI 1000

Siemens Uroskop AccessASPIA platform

Page 131: Siemens Setup Manuals

Siemens C-arm Uroskop Access with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n under Image Quality, Grayscale Image Quality: n Contrast=7 (Always=Y) n TFT Set (From list)=Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 132: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens CT Plus-S, AR, Plus 4 with LASER IMAGERS

Important note: from beg. 2001 CT models Balance/Emotion/Esprit switched to the Somaris 5 syngo-based platform (see setup there).

Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer.................................................. 3 n Kodak DryView 8700 LASER IMAGER / Plus............................................................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ....................................................... 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer.................................................. 6 n Kodak DryView 8500 LASER IMAGER / Plus............................................................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ....................................................... 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer.................................................. 9 n Kodak DryView 8300 LASER IMAGER / Standalone.................................................... 10 n Kodak Digital Science 969 HQ LASER IMAGER...................................................... 11 n Kodak Digital Science 969 HQT LASER IMAGER ................................................... 12 n Kodak Digital Science 959 XL LASER IMAGER ...................................................... 13 n Kodak DryView 8100 LASER IMAGER......................................................................... 14 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) ...... 15 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8100 LASER IMAGER......................................................................... 17 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8300 LASER IMAGER......................................................................... 19 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 21 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 23 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 25 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) . 27 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4).................................................................... 29 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4).................................................................... 31 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8900 LASER IMAGER ........................................................................ 33

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 133: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 35 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 36 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 37 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8100 LASER IMAGER......................................................................... 39 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8300 LASER IMAGER......................................................................... 41 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 43 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 45 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 47 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (3,4,5) /

Kodak DryView 8200 LASER IMAGER......................................................................... 49 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 51 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 53 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 55 n Kodak DryView 8900 LASER IMAGER......................................................................... 57 n Kodak DryView 8150 LASER IMAGER......................................................................... 59 n Kodak Color Medical Imager 1000 ................................................................................. 61

Page 134: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens CT with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pin Host Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

Keypad Siemens 25-pin Control Cable

Siemens 37-pin Data Cable

Siemens CT

8700 Dual Fiber Cable 3 M 8 7 0 0 D r y V i e w

3 M 8 8 0 0 M u l t i - I n p u t M a n a g e r

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, 8800 rel. 4.2, 8700 rel. 1.15 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File DRYVIEW (if not available HQ) n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=XL, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=B3C5, Dmax=3.00, Contrast=8, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=13

n on EIB Menu: Parity=Disable, Timeout=10

Page 135: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens CT with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostSPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

8700 Plus

3M 8700 DryView

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: 8700 rel. 1.15 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File DRYVIEW (if not available HQ) n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8700 Plus Setup: n on COMM Menu: Siemens Default n on SIEMENS Menu:

n Modality=Somatom, Timeout=10, Smooth Beta=13, Sharp Beta=13 n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=B3C5, Dmax=3.00, Contrast=8, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=10

Page 136: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Siemens CT with Kodak DryView 8700 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

8700 Standard

3M 8700 DryView

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: 8700 rel. 1.15 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. Setup: n on Siemens CT install Camera Config.File DRYVIEW (if not available HQ) n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25

Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8700 Standard Setup: n on TDB/C board: Jumpers=RS232, Switch=Right n on COMM Menu: Siemens Default n on SIEMENS Menu:

n Modality=Somatom, Timeout=10, Smooth Beta=13, Sharp Beta=13 n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=B3C5, Dmax=3.00, Contrast=8, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=10

Page 137: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens CT with Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pin Host Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

Keypad Siemens 25-pin Control Cable

Siemens 37-pin Data Cable

Siemens CT

8500 Dual Fiber Cable 3 M 8 7 0 0 D r y V i e w 3 M 8 8 0 0 M u l t i - I n p u t M a n a g e r

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, 8800 rel. 5.1, 8500 rel. 1.22 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=B3C5, Dmax=3.00, Contrast=8, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=13

n on EIB Menu: Parity=Disable, Timeout=10

Page 138: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Siemens CT with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

8500 Plus

3M 8700 DryView

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, 8500 rel. 1.22 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8500 Plus Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=B3C5, Dmax=3.00, Contrast=8, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=13

n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=10

Page 139: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens CT with Kodak DryView 8500 LASER IMAGER / Standard

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

8500 Standard

3M 8700 DryView

Imager

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, 8500 rel. 1.22 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Center n on COMM Menu: 959 Default n on IMAGE Menu:(note: image quality setup proposed by Kodak)

n TFT=B3C5, Dmax=3.00, Contrast=8, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=13

n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=10

Page 140: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Siemens CT with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

DEIB Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB 37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

RS232 25-to-9 pin Host Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

Keypad Siemens 25-pin Control Cable

Siemens 37-pin Data Cable

Siemens CT

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, 8800 rel. 5.1, 8300 rel. 4.4 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=16, LUT=7 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

8300 Setup: n on 8300 Operator Menu set: Film Layout: Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control:1200,8,1,Even,3M; Digital Interface:Parity=None n Modality Group=0 (note: image quality setup proposed by Kodak)

8800 Setup: n on COMM Menu: 959 Default; on IMAGE Menu:Density=16, Contrast=7 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=13

n on EIB Menu: Parity=Disable, Timeout=10

Page 141: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens CT with Kodak DryView 8300 LASER IMAGER / Standalone

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

ImagerHost

Siemens Host Protocol Translator

RS422 9-pinCopper Cable

SPCI

SPDI

Keypad

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

8300

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, 8300 rel. 4.4 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=16, LUT=7 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8300 Setup: n on 8300 Operator Menu set:

n Density=16 n Contrast=7 n Film Layout: Format=1on 1, 2 on 1, 4 on 1, 6 on 1, Mode=Portrait

n on 8300 Service Menu set: n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8,

Nbr. of Stop bits=1, Parity=Even, Protocol=3M n Digital Interface: Parity=None, Modality Group=0

Page 142: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Siemens CT with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

3 M H Q L a s e r I m a g e r

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, HQ rel. 4.2 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT.

Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=6 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

M969 HQ Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=693C0, Dmax=3.00, Contrast=6, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu: Parity=Disable, Timeout=10

Page 143: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens CT with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQTRS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

3 M H Q L a s e r I m a g e r

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0. Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=6, LUT=8 and press Set Parameters into Exposure->Job Controller: press Continue

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25

Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQT Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Right n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Somatom, Timeout=10 n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=693C0, Contrast=8, Density=6, on OIC Menu: Chemistry=2 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=10

Page 144: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Siemens CT with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

3M L a ser I m ag er

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT rel. 1.3, XL rel. 3.8 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. Setup: n on Siemens CT install Camera Config.File XL n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density & LUT depending on chemistry

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=XL, Timeout=10 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M959 XL Setup: n on COMM Menu: 959 Default n on EIB Menu: Parity=Disable, Timeout=10

Page 145: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens CT with Kodak DryView 8100 LASER IMAGER

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

DryView 8100

Imager

RS422 9-pole Plug

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT v1.3, 8100 v1.1 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. Setup: n on Siemens CT install Camera Config.File XL or HQ or DRYVIEW n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters

into Exposure->Job Controller: press Continue n on SHPT Service Screen set Modality=Somatom, Camera Type=XL, Timeout=10 n on SHPT Service Screen set Sharp Beta=13, Smooth Beta=13 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=13 n on IMAGE QUALITY-> TFT FILES Menu: TFT=PMS n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Disable

Page 146: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Siemens CT via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

DPCCopper Cable

DPI4-to-DPC Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

Fiber Cable

Fiber Cable

25-9 DPC-UKEIB Cable

Kodak 9410 PACS Link

3M8700 DryView

Kodak DryView 8700 Plus Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT v1.3, 9410 v1.6, 8700 v1.26 Note: This setup is basically also valid for 9410 v1.3.1a and v1.5.1 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers. Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File DRYVIEW (if not available HQ) n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom,Camera Type=XL, Timeout=10 n on SHPT Service Screen set Sharp Beta=13, Smooth Beta=13 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

Page 147: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=10, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ct, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8700, Film Destination=Processor, Printer1=8700(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=b3c5.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Dest.=Printer 1, Media Size=14x17, C=8, D=14 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Density=14, Dmax=3.00, Contrast=6 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 148: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Siemens CT via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

Kodak DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

Kodak 9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT v1.3, 9410 v1.6, 8100 v2.1.2 Note: This setup is basically also valid for 9410 v1.3.1a and v1.5.1 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File XL or HQ or DRYVIEW n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8 and press Set Parameters

into Exposure->Job Controller: press Continue n on SHPT Service Screen set Modality=Somatom, Camera Type=XL, Timeout=10 n on SHPT Service Screen set Sharp Beta=13, Smooth Beta=13 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 149: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=10, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ct, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8100, Film Destination=Processor, Printer1=8100(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=B3c5ax4.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=8, D=14 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 150: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Siemens CT via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens CT

Kodak DryView 8300

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

Kodak 9410 PACS Link

COPCIL BoardCopper Cable

Imager

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: SHPT v1.3, 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B, 8300 16 MB Note: This setup is basically also valid for 9410 v1.3.1a and v1.5.1 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File 3M_HQ n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=7 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=10 n on SHPT Service Screen set Sharp Beta=0, Smooth Beta=0 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right Note: n power-up the UKEIB separately so that the UKEIB is always on, i.e., not from CT,

otherwise when CT is switched-off, also UKEIB is off and host control link is lost. n on Siemens CT select on Exposure->Settings the film size 8x10 and the format 6:1.

In this case CT image matrix is 512, due to max. 8300 printable format i.e., 6:1, max 6 images will be printed on each 8300 film. Note that for the Somaris 2 platform a 512 patch must be installed on CT, otherwise the matrix is 1024 and therefore only 4:1 format is possible on 8300 (due to the max printable pixels of 8300).

Page 151: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=10, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ct, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8300, Film Destination=Processor, Printer1=8300(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=u1_109b.w8u, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=8x10, C=7, D=14 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 152: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: MIM 200 v6.1, KELI 160 v5.2 Note: This setup is basically also valid for MIM 200 v3.2.1, v4.0, v5.0, v5.2, v6.0 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File Kodak XLP n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=280 (i.e., Dmax), LUT=3 (i.e., Curve Shape=3.0)

Contrast=500 (i.e., Film Contrast=0) and press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Somatom Power: n Board/Channel=Digital Board 1 Channel 1, Logical Name=siemct, n Mod.Name=ct, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On

Page 153: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=2.80, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 154: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: This setup is basically also valid for MIM 200 v3.2.1, v4.0, v5.0, v5.2, v6.0 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File Kodak XLP n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=280 (i.e., Dmax), LUT=3 (i.e., Curve Shape=3.0)

Contrast=500 (i.e., Film Contrast=0) and press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Somatom Power: n Board/Channel=Digital Board 1 Channel 1, Logical Name=siemct, n Mod.Name=ct, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue)

Page 155: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=2.80, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 156: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: This setup is basically also valid for MIM 200 v3.2.1, v4.0, v5.0, v5.2, v6.0 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File Kodak XLP n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=280 (i.e., Dmax), LUT=3 (i.e., Curve Shape=3.0)

Contrast=500 (i.e., Film Contrast=0) and press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Somatom Power: n Board/Channel=Digital Board 1 Channel 1, Logical Name=siemct, n Mod.Name=ct, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue)

Page 157: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=2.80, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 158: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Fiber Cable

3M 8700 DryView

Kodak DryView 8700 Plus

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for MIM 200 v5.0.1, v5.2, v6.0 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras by basically using the correspondent Model into MIM 200 Destinations and if HQ by installing HQ into Siemens Camera Config.File. Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File DRYVIEW (if not available HQ) n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Somatom Power:

n Board/Channel=Digital Board 1 Channel 1, Logical Name=sct, n Mod.Name=sct, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=13, Interpolation Smooth=13

Page 159: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=13, Film Contrast=8 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=B3c5ax4.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 160: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable25-to-25 Null

Modem Cable COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

Kodak DryView 8100

RS4229-pole Plug

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for MIM 200 v5.0.1, v5.2, v6.0 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File DRYVIEW (if not available HQ) n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=8

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Somatom Power: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sct, n Mod.Name=sct, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=13, Interpolation Smooth=13 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Page 161: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=13, Film Contrast=8 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=B3c5ax4.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 162: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25-to-25 NullModem Cable COPCIL Board

Copper Cable

Control 9-pin

Data 37 pin

Kodak DryView 8300

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: CT series from Somatom Plus till Somatom Plus 4 (i.e., Somaris 2,3,4) Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for MIM 200 v5.0.1, v5.2, v6.0 Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT. CT Setup: n on Siemens CT install Camera Config.File HQ n on Siemens CT select on Exposure->Settings the film size 8x10 and the format 6:1 n on Siemens CT to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=16, LUT=7

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Somatom Power: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sct, n Mod.Name=sct, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=0, Interpolation Smooth=0 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue

Page 163: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8300, Media Size Select=8x10in n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=0, Film Contrast=7 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=u1_109b.w8u, Auto Study=Off, Console=On, Annotation=Off 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 164: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

Siemens CT via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8900 LASER IMAGER

Requirements: CT series from Somatom Plus till Somatom Plus 4 (ie Somaris 2,3,4) Requirements: MIM200 v6.1 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on some old CT, if you want to configure a new camera because you are replacing an existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera, i.e., on Siemens CT configure CT with camera=None, boot CT like this, and then install the new camera, i.e., on Siemens CT configure CT with, e.g., camera=3M 959 and reboot CT CT Setup: n on Siemens CT install Camera Config.File Kodak 2180 (or XLP) n on Siemens CT to set Density and Contrast for the Camera: into Exposure->Job Controller: press Stop into System->Camera: set Density=280 (ie Dmax),

LUT=3 (ie Curve Shape=3.0) Contrast=500 (ie Film Contrast=0) and press Set Parameters

into Exposure->Job Controller: press Continue MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

ie delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.= Somatom Power:

n Board/Channel=Digital Board 1 Channel 1, Logical Name= sct, n Mod.Name=sct, Primary Control: Type= Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1

n on Configure, Destination, Add, Print, Network, Qualified, 8900, Set:

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens CT

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25-to-25 NullModem Cable

Kodak DryView 8900

Kpad / Host Control Octopus Adaptor Cable

DICOM Network

Page 165: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

n General: Log.Name=8900, IPAddr=accordingly n General: Database=8900, Model=8900, Memory=32 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n DICOM Info: Protocol=DICOM 3.0, Service Class=Basic Grayscale Print n DICOM Info: Port=5040,AETitle=NER_8900,Counter=40,Response=100 n Supported Items: Collation=On, Common Text=On, Tonescaling=On n Supported Items: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnif=On, Bilinear=On, Replic=On, Cubic Spline=On n Interpolation: Cubic Convolution 2=On, Cubic Convolution 3=On n Format Types: Custom Formats=On, Row Symm.=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.3 n SCU: Luminance Space= On, Variable Border Density=On n SCU: Curve Shape=On, Perception LUT =On, PLUT Service=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8900, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=13, Film Contrast=8 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=B3c5ax4.w87, Auto Study=Off, Console=On, Annotation=Off

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

Page 166: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= B3c5ax4.w87 (Always=Y) n Contrast= 8 (Always=Y), Smoothing Type=13 (Always=Y) n Dmin=0.00 (Always=N), Dmax= 3.00 (Always=Y) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ct

Page 167: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

Siemens CT via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens CTSomaris 4 platform- AR Star (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak DryView 8300

DICOM Network

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: 8300 DICOM parameters: port=104, AE title=IMN_8300. Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera

in this case use Dmax=300, C=10, Modality Group=0 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera

in this case use Dmax=300, C=1, Modality Group=4 CT Setup: n on CT into System/Config/Network declare camera IP Addr, AE Title, Port n on CT into System/Config/Camera/Details set:

Filmsize=8x10, Orient.=Portrait, Division=e.g., STANDARD 3x2 Add, MaxD=300 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT or LUT_022 (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 10 or b) 1, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set: Modality Group=a) 0 or b) 4

Page 168: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Siemens CT via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

DICOM Network

Kodak 190 camera

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: 190 rel. 1.7.29 Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=280, Curve Shape=3.0, Film Contrast=0 (use a) configuration in case also a Virtuoso workstation is printing on same camera) b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=2.80, Curve Shape=a) 3.0 or b) 0.0, Contrast=0 n Contrast Pivot Density=1.2, IPAddress=accordingly n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 169: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Siemens CT via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: 9410 v1.6, 8700 v1.26 Note: This setup is basically also valid for 9410 v1.3.1a and v1.5.1 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers. Note: CT AE Title ends with last 4 digits DBPR (not 0000) e.g., 049SA1CTXYDBPR. Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=300, C=8, TFT=B3C5 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=a) 300 or b) 280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT or CTdry (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0

Page 170: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers:

n Printer=8700, AE Title=IMN_9410, Port=1024, Max Associations=5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=e.g., 049SA1CTXYDBPR, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 8 or b) 3 n TFT/ULUT=a) b3c5.w87 or b) Wrkstn2a.w87 n Max.Density=a) 300 or b) 280, Border=0, Mag.Type=8, Smoothing=13 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Density=14, Dmax=3.00, Contrast=6 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 171: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Siemens CT via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens CTSomaris 4 platform- AR Star (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: 9410 v1.6, 8100 v2.1.2 Note: This setup is basically also valid for 9410 v1.3.1a and v1.5.1 Note: CT AE Title ends with last 4 digits DBPR (not 0000) e.g., 049SA1CTXYDBPR Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=300, C=8, TFT=B3C5 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, C=1, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=a) 300 or b) 280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT or CTdry (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interp.Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=IMN_9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users:

Page 172: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

n SCU AETitle=e.g., 049SA1CTXYDBPR, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 8 or b) 1 n TFT/ULUT=a) b3c5.w87 or b) Wrkstn2a.w87 n Max.Density=a) 300 or b) 280, Border Density=0, Mag.Type=8, Smoothing=13 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 173: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Siemens CT via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 9410 v1.3.1a and v1.5.1 Note: CT AE Title ends with last 4 digits DBPR (not 0000) e.g., 049SA1CTXYDBPR. Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=300, C=10, Modality group=0 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, Modality group=4 CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=8x10, Orient.=Portrait, Division=e.g., STANDARD 3x2 Add, Max Density=300 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT or LUT_022 (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8300, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=IMN_9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users:

Page 174: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

n SCU AETitle=e.g., 049SA1CTXYDBPR, IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 10 or b) 1, n TFT/ULUT=a) u1_109b.w8u or b) wrkstn83a.w8u n Max.Density=300, Border=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 175: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

Siemens CT via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, KELI 160 v5.2 Note: This setup is basically also valid for MIM 200 v3.2.1, v4.0, v5.0, v5.2, v6.0 Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=280, Curve Shape=434 (i.e., 3.0), Film Contrast=0 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On

Page 176: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 160 Setup: no modality-specific setup needed

Page 177: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

Siemens CT via DICOM with PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200 Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: This setup is basically also valid for MIM 200 v3.2.1, v4.0, v5.0, v5.2, v6.0 Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=280, Curve Shape=3.0, Film Contrast=0 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue)

Page 178: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 179: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

Siemens CT via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200 Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, 1120 v2.40/032 Note: This setup is basically also valid for MIM 200 v3.2.1, v4.0, v5.0, v5.2, v6.0 Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=280, Curve Shape=3.0, Film Contrast=0 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue)

Page 180: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 181: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

Siemens CT via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for MIM 200 v4.0, v5.0, v5.2, v6.0 Note: This setup is basically also valid for 25 PS computer Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=280, C=8, TFT=B3C5AX4 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear)

Page 182: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +8 or b) +3 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=13 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 183: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

Siemens CT via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for MIM 200 v5.0, v5.2, v6.0 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination. Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=300, C=8, TFT=B3C5AX4 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=a) 300 or b) 280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 184: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 8 or b) 3 (Always=Y) n ImageDmin=0.00(Always=N),ImageDmax=a)3.00 or b)2.80(Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=13 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 185: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

Siemens CT via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for MIM 200 v5.0, v5.2, v6.0 Note: This setup is basically also valid for 25 PS computer Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=300, C=8, TFT=B3C5AX4 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=280, C=1, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=e.g., STANDARD 5x4 Add, Max Density=a) 300 or b) 280 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Page 186: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 8 or b) 3 (Always=Y) n ImageDmin=0.00(Always=N),ImageDmax=a)3.00 or b)2.80(Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=13 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 187: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 56

Siemens CT via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance/Esprit

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: CT AR VB41A, CT Plus 4 VB40A, CT Balance/Emotion/Esprit VA10A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for MIM 200 v5.0, v5.2, v6.0 Note: This setup is basically also valid for 25 PS computer Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT a) if LUT=linear then Image Data not lutted by CT, lutted by Camera in this case use Dmax=300, C=10, Modality group=0 b) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, Modality group=4 CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=8x10, Orient.=Portrait, Division=e.g., STANDARD 3x2 Add, Max Density=300 a) LUT=linear (i.e., Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT or LUT_022 (i.e., Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60

Page 188: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 57

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) u1_109b.w8u or b) wrkstn83a.w8u (Always=Y) n Contrast (dry)=a) 10 or b) 1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 189: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 58

Siemens CT via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: CT AR VB41A, CT Plus 4 VB40A Requirements: CT Balance/Emotion/Esprit VA10A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT c) if LUT=linear then Image Data not lutted by CT, lutted by Camera

in this case use Dmax=300, C=8, TFT=B3C5AX4 d) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera

in this case use Dmax=280, C=3, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=eg STANDARD 5x4 Add, Max Density=a) 300 or b) 280 a) LUT=linear (ie Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (ie Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (ie smooth) 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

DICOM Network

Kodak DryView 8900

Page 190: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 59

n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 8 or b) 3 (Always=Y), Smoothing Type=13 (Always=N) n Dmin=0.00 (Always=N), Dmax= a)3.00 or b)2.80 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ct

Page 191: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 60

Siemens CT via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: CT AR VB41A, CT Plus 4 VB40A Requirements: CT Balance/Emotion/Esprit VA10A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT e) if LUT=linear then Image Data not lutted by CT, lutted by Camera

in this case use Dmax=300, C=8, TFT=B3C5AX4 f) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera

in this case use Dmax=280, C=1, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=14x17, Orient.=Portrait, Division=eg STANDARD 5x4 Add, Max Density=a) 300 or b) 280 a) LUT=linear (ie Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (ie Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (ie smooth) 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 seriesSomaris 45 platform- Emotion / Balance / Esprit

DICOM Network

Kodak DryView 8150

Page 192: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 61

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name= a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast=a) 8 or b) 1 (Always=Y), Smoothing Type=13 (Always=N) n Dmin=0.00 (Always=N), Dmax=a)3.00 or b)2.80 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ct

Page 193: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 62

Siemens CT via DICOM with Kodak Color Medical Imager 1000

Requirements: CT AR VB41A, CT Plus 4 VB40A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Siemens CT could be configured with a) LUT=linear or b) LUT=CTLUT g) if LUT=linear then Image Data not lutted by CT, lutted by Camera

in this case use Dmax=300, C=8, TFT=B3C5AX4 h) if LUT=CTLUT then Image Data lutted by CT, linear-in-Density LUT into Camera

in this case use Dmax=280, C=7, TFT=WRKSTN2A CT Setup: n on CT into System/Config/Network declare for the camera:

Basic Print, Host Name, Log.Name, IP Addr, Port, AE Title, SUN, Online n on CT into System/Config/Camera/Details set:

Filmsize=8x10, Orient.=Portrait, Division=eg STANDARD 3x2 Add, Max Density=a) 300 or b) 280 a) LUT=linear (ie Image Data not lutted by CT, lutted by Camera) b) LUT=CTLUT (ie Image lutted by CT, linear LUT in Camera)

n on CT into Exposure/Settings set Graduation=smt (ie smooth) CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 8 or b) 7 (Always=Y)

DICOM Network

Kodak CMI 1000

Siemens CTSomaris 4 platform- ARStar (not ART)- Plus 4 series

Page 194: Siemens Setup Manuals

Siemens CT platforms Somaris 2, 3, 4, based on SUN with LASER IMAGER Products

Author: [email protected], Edition: May ´05 63

n TFT Set (From list)=a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=13 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 195: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens CT Volume Zoom / Access / Balance / Emotion / Esprit / Sensation / Smile / Spirit with LASER IMAGERS Important note: from beg. 2001 CT models Balance/Emotion/Esprit switched to the Somaris 5 syngo-based platform (see here below). Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8100 LASER IMAGER......................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8300 LASER IMAGER......................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (3,4,5) /

Kodak DryView 8200 LASER IMAGER......................................................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22 n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 196: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens CT syngo platform via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak DryView 8300

DICOM Network

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=10, Modality Group=0

b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 10 or b) 1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=a) 0 or b) 4

Page 197: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens CT syngo platform via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

DICOM Network

Kodak 190 camera

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: 190 rel. 1.7.29 Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=2.80 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=280, Curve Shape=3.0, Film Contrast=0 (use a) config. in case also a Virtuoso workstation is printing on same camera) b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=2.80

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=2.80, Curve Shape=a) 3.0 or b) 0.0, Contrast=0 n Contrast Pivot Density=1.2, IPAddress=accordingly n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 198: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens CT syngo platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and if HQ by installing HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT=WRKSTN2A syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

9410 Setup:

Page 199: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 9 or b) 3 n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 n Max.Density=a) 300 or b) 280, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 200: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens CT syngo platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: 9410 v1.6, 8100 v2.4.1

Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=1, TFT=WRKSTN2A syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831

Page 201: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 9 or b) 1 n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 n Max.Density=a) 300 or b) 280, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 202: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens CT syngo platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=10, Modality Group=0 b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4 syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0

Page 203: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 10 or b) 1 n TFT/ULUT=a) u1_109b.w8u or b) wrkstn83a.w8u n Max.Density=a) 300 or b) 280, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 204: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=2.80 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=280, Curve Shape=434 (i.e., 3.0), Film Contrast=0 b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=2.80 SC Image=a) linear or b) CTLUT, Max Density=2.80

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Page 205: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 206: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=2.80 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=280, Curve Shape=3.0, Film Contrast=0 b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=2.80

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 207: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 208: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, 1120 v2.40/032 Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=2.80 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=280, Curve Shape=3.0, Film Contrast=0 b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, Curve Shape=0.0, Film Contrast=0 syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=2.80

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 209: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 210: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=2.80 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=280, C=8, TFT=B3C5AX4 b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT=WRKSTN2A syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=2.80

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add:

Page 211: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) B3c5ax4.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +8 or b) +3 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 212: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and if HQ by installing HQ into Siemens CT DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT=WRKSTN2A syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

Page 213: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 9 or b) 3 (Always=Y) n Dmin=0.00 (Always=N), Dmax=a) 3.00 or b) 2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 214: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=1, TFT=WRKSTN2A syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 215: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 9 or b) 1 (Always=Y) n Image Dmin=0.00 (Always=N) n Image Dmax=a) 3.00 or b) 2.80 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 216: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Siemens CT syngo platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT a) into Local Service/Config/DICOM LUT files set CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=10, Modality Group=0 b) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4 syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT (or CTLUTdry), Max Density=a) 3.00 or b) 2.80

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add:

Page 217: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) u1_109b.w8u or b) wrkstn83a.w8u (Always=Y) n Contrast (dry)=a) 10 or b) 1 (Always=N) n Image Dmin=0.00 (Always=N) n Image Dmax=a) 300 or b) 280 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Film Output Dest=Bin 9 (Always=N)

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 218: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Siemens CT syngo platform via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: CT Zoom/Access VA20A, CT Balance/Emotion/Esprit VA30A Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40A Requirements: CT Sensation VA50A/VA60A/VA70A/VB10A, CT Smile VA10A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT c) into Local Service/Config/DICOM LUT files set

CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K

d) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=3, TFT= WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=a) 3.00 or b) 2.80

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

DICOM Network

Kodak DryView 8900

Page 219: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 9 or b) 3 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax= a) 3.00 or b) 2.80 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ct

Page 220: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Siemens CT syngo platform via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40C/VA47A Requirements: CT Sensation VA50A/VA60A/VA70A/VB19C, Smile VA10A Requirements: CT Sensation/Emotion VB10B Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT e) into Local Service/Config/DICOM LUT files set

CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB

f) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=1, TFT= WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=a) 3.00 or b) 2.80

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile

DICOM Network

Kodak DryView 8150

Page 221: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 9 or b) 1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=a) 3.00 or b) 2.80 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ct

Page 222: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Siemens CT syngo platform via DICOM with Kodak Color Medical Imager 1000

Requirements: CT Zoom/Access/Balance/Emotion/Esprit VA40C/VA47A Requirements: CT Sensation VA50A/VA60A/VA70A/VB19C, Smile VA10A Requirements: CT Sensation/Emotion/Spirit VB10B/VB20A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: syngo could be configured with a) LUT=linear or b) LUT=CTLUT g) into Local Service/Config/DICOM LUT files set

CT Image=linear , MaxDens=3.00 if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K

h) into Local Service/Config/DICOM LUT files set CT Image=CTLUT, MaxDens=2.80 if LUT=CTLUT then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=280, C=7, TFT= WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set CT Image=a) linear or b) CTLUT, Max Density=a) 3.00 or b) 2.80

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y):

DICOM Network

Kodak CMI 1000

Siemens CTSomaris 5 syngo platform- Volume Zoom / Access- Emotion / Balance / Esprit- Sensation- Smile / Spirit

Page 223: Siemens Setup Manuals

Siemens CT platform Somaris 5, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 9 or b) 7 (Always=Y) n TFT Set (From list)=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 224: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens DR FD Thorax / Multix / Vertix / Aristos with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8100 LASER IMAGER......................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8300 LASER IMAGER......................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 160 LASER IMAGER .......................................................................... 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (3,4,5) / Kodak DryView 8200 LASER IMAGER......................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 225: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens FD via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8300

DICOM Network

Requirements: FD syngo platform VA20K Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 4 or b) 1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=a) 2 or b) 4

Page 226: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens FD via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

DICOM Network

Kodak 190 camera

Requirements: FD syngo platform VA20K Requirements: 190 rel. 1.7.29 Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=a) 3.0 or b) 0.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 227: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens FD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: FD syngo platform VA20K Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

Page 228: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 4 or b) 2 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Density=14, Dmax=3.00, Contrast=6 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 229: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens FD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: FD syngo platform VA20K Requirements: 9410 v1.6, 8100 v2.4.1 Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Page 230: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 4 or b) 2 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 231: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens FD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: FD syngo platform VA20K Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

Page 232: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 4 or b) 1 n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 233: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=434 (i.e., 3.0), Film Contrast=0

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30,

Page 234: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 235: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, 2180 v2.17H Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180

Page 236: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Modality=OT (Always=N) n Border=3.99 (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 237: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, 1120 v2.40/032 Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120

Page 238: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 239: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40,

Page 240: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +4 or b) +2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 241: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup:

Page 242: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 4 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 243: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 244: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 4 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 245: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Siemens FD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens FD Flat DetectorThorax / MultixRADIS syngo platform

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: FD syngo platform VA20K Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=CR a) into Local Service/Config/DICOM LUT files set CR Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set CR Image=CR, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

Page 246: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u (Always=Y) n Contrast (dry)=a) 4 or b) 1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 247: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Siemens FD via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: FD syngo platform VA20K Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: syngo could be configured with a) LUT=linear or b) LUT=CR c) into Local Service/Config/DICOM LUT files set CR Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

d) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900

DICOM Network

Kodak DryView 8900

Siemens Flat DetectorFD Image SystemRADIS syngo platform-Thorax / Multix / Vertix- Axiom Aristos

Page 248: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 4 or b) 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=fd

Page 249: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Siemens FD via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: FD syngo platform VA20K Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: syngo could be configured with a) LUT=linear or b) LUT=CR e) into Local Service/Config/DICOM LUT files set CR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

f) into Local Service/Config/DICOM LUT files set CR Image=CR, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any

DICOM Network

Kodak DryView 8150

Siemens Flat DetectorFD Image SystemRADIS syngo platform-Thorax / Multix / Vertix- Axiom Aristos

Page 250: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast=a) 4 or b) 1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=fd

Page 251: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Siemens FD via DICOM with Kodak Color Medical Imager 1000

Requirements: FD platform Syngo VA20K Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: syngo could be configured with a) LUT=linear or b) LUT=CR g) into Local Service/Config/DICOM LUT files set CR Image=linear

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

h) into Local Service/Config/DICOM LUT files set CR Image=CR if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=7, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set CR Image=a) linear or b) CR, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000

DICOM Network

Kodak CMI 1000

Siemens Flat DetectorFD Image SystemRADIS syngo platform-Thorax / Multix / Vertix- Axiom Aristos

Page 252: Siemens Setup Manuals

Siemens DR model FD Thorax / Multix / Vertix / Aristos with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 4 or b) 7 (Always=Y) n TFT Set (From list)=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 253: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens DSA Axiom Artis with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8100 LASER IMAGER......................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8300 LASER IMAGER......................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (3,4,5) /

Kodak DryView 8200 LASER IMAGER......................................................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22 n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 254: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Axiom Artis via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak DryView 8300

DICOM Network

Requirements: Axiom Artis syngo platform VA10B Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 4 or b) 1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=a) 2 or b) 4

Page 255: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Axiom Artis via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens Axiom Artis syngo platform

DICOM Network

Kodak 190 camera

Requirements: Axiom Artis syngo platform VA10B Requirements: 190 rel. 1.7.29 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=a) 3.0 or b) 0.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 256: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Axiom Artis via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens Axiom Artissyngo platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Axiom Artis syngo platform VA10B Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and if HQ by installing HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

9410 Setup:

Page 257: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 4 or b) 2 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 258: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Axiom Artis via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Axiom Artis syngo platform VA10B Requirements: 9410 v1.6, 8100 v2.4.1 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831

Page 259: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 4 or b) 2 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 260: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Axiom Artis via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Axiom Artis syngo platform VA10B Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831

Page 261: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 4 or b) 1 n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 262: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=434 (i.e., 3.0), Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 263: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 264: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens Axiom Artissyngo platform

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, 2180 v2.17H Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 265: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 266: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens Axiom Artissyngo platform

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, 1120 v2.40/032 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 267: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 268: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Page 269: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +4 or b) +2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 270: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens Axiom Artissyngo platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and if HQ by installing HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

Page 271: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 4 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 272: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Page 273: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 4 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 274: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Axiom Artis via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens Axiom Artissyngo platform

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Axiom Artis syngo platform VA10B Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add:

Page 275: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u (Always=Y) n Contrast (dry)=a) 4 or b) 1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 276: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Axiom Artis via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Axiom Artis syngo platform VA10B Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: syngo could be configured with a) LUT=linear or b) LUT=xa c) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

d) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM

Siemens Axiom Artissyngo platform

DICOM Network

Kodak DryView 8900

Page 277: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 4 or b) 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=artis

Page 278: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Axiom Artis via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Axiom Artis syngo platform VB11 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: syngo could be configured with a) LUT=linear or b) LUT=xa e) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

f) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

Siemens Axiom Artissyngo platform

DICOM Network

Kodak DryView 8150

Page 279: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast=a) 4 or b) 1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=artis

Page 280: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Axiom Artis via DICOM with Kodak Color Medical Imager 1000

Requirements: Axiom Artis syngo platform VB11 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: syngo could be configured with a) LUT=linear or b) LUT=xa g) into Local Service/Config/DICOM LUT files set XA Image=linear

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

h) into Local Service/Config/DICOM LUT files set XA Image=xa if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=7, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly

DICOM Network

Kodak CMI 1000

Siemens Axiom Artissyngo platform

Page 281: Siemens Setup Manuals

Siemens DSA Axiom Artis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 4 or b) 7 (Always=Y) n TFT Set (From list)=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 282: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens DSA Fluorospot Compact with LASER IMAGERS (note: different models of Iconos, Siregraph, Sireskop could have either the setup of Fluorospot TOP or the setup of Fluorospot Compact) Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer.................................................. 3 n Kodak DryView 8700 LASER IMAGER / Plus............................................................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ....................................................... 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer.................................................. 6 n Kodak DryView 8500 LASER IMAGER / Plus............................................................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ....................................................... 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer.................................................. 9 n Kodak DryView 8300 LASER IMAGER / Standalone.................................................... 10 n Kodak Digital Science 969 HQ LASER IMAGER...................................................... 11 n Kodak Digital Science 969 HQT LASER IMAGER ................................................... 12 n Kodak Digital Science 959 XL LASER IMAGER ...................................................... 13 n Kodak DryView 8100 LASER IMAGER......................................................................... 14 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 15

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8100 LASER IMAGER......................................................................... 17

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 160 LASER IMAGER .......................................................................... 19

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 21

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 23

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4) ............................... 25

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4).................................................................... 27

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 283: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 29 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 30 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 31

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8100 LASER IMAGER......................................................................... 33

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8300 LASER IMAGER......................................................................... 35

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 160 LASER IMAGER .......................................................................... 37

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 39

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 41

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................43

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 45

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 47

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 49

n Kodak DryView 8900 LASER IMAGER......................................................................... 51 n Kodak DryView 8150 LASER IMAGER......................................................................... 53 n Kodak Color Medical Imager 1000 ................................................................................. 55

Page 284: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens Fluorospot Compact with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-Input Manager

Video Cable for FootswitchFootswitch

Requirements: Fluoro Compact rel. VA01A, 8800 rel. 5.1, 8700 rel. 1.22 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8800/8700 Dual Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEFL87B, Dmax=3.00, Contrast=4, Density=14 n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 285: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens Fluorospot Compact with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

8700 Plus

3M 8700 DryView

Video Cable for FootswitchFootswitch

Requirements: Siemens Fluoro Compact rel. VA01A, 8700 Plus rel. 1.22 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8700 Plus Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEFL87B, Dmax=3.00, Contrast=4, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 286: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Siemens Fluorospot Compact with Kodak DryView 8700 LASER IMAGER / Standard

Video cable for Footswitch

Keypad

SPDI

Siemens 37-pinData Cable

SiemensFluorospot Compact

8700 Standard

3M 8700 DryView

Requirements: Fluorospot Compact rel. VA01A, 8700 Standard rel. 1.22 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=SIEFL87B, Dmax=3.00, Contrast=4, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 287: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens Fluorospot Compact with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

8500 DualFiber Cable

3M 8700 DryView

3M8800Multi-Input Manager

Video Cable for FootswitchFootswitch

Requirements: Fluoro Compact rel. VA01A, 8800 rel. 5.1, 8500 rel. 1.22 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8800/8500 Dual Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEFC969 (or SIEFL87B), Dmax=3.00, Contrast=2, Density=14 n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 288: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Siemens Fluorospot Compact with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

8500 Plus

3M 8700 DryView

FootswitchVideo cable for Footswitch

Requirements: Fluorospot Compact rel. VA01A, 8500 Plus rel. 1.22 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8500 Plus Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEFC969 (or SIEFL87B), Dmax=3.00, Contrast=2, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200 n on KEYPAD Menu:

n Smooth Beta=2

Page 289: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens Fluorospot Compact with Kodak DryView 8500 LASER IMAGER / Standard

Video cable for Footswitch

Keypad

SPDI

Siemens 37-pinData Cable

SiemensFluorospot Compact

8500 Standard

3M 8700 DryView

Requirements: Fluoro Compact rel. VA01A, 8500 Standard rel. 1.22 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8500 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=SIEFC969 (or SIEFL87B), Dmax=3.00, Contrast=2, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 290: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Siemens Fluorospot Compact with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

3M8800M ulti-Input Manager

FootswitchVideo Cable for Footswitch

Requirements: Fluoro Compact rel. VA01A, 8800 rel. 5.1, 8300 rel. 4.4 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n Modality Group=2

8800 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: Density=15, Contrast=4 n on EIB Menu: Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 291: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens Fluorospot Compact with Kodak DryView 8300 LASER IMAGER / Standalone

Keypad

SPDI

Siemens 37-pinData Cable

SiemensFluorospot Compact 8300

Video Cable for Footswitch

Requirements: Siemens Fluorospot Compact rel. VA01A, 8300 rel. 4.4 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. 8300 Setup: n on 8300 Operator Menu set:

n Density=15 n Contrast=4 n Film Layout : Format=1on 1, Mode=Portrait

n on 8300 Service Menu set: n Serial Control Interface: Protocol=Keypad n Digital Interface: Parity=Even n Modality Group=2

Page 292: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Siemens Fluorospot Compact with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

3 M H Q L a s e r I m a g e r

Video Cable for FootswitchFootswitch

Requirements: Fluorospot Compact rel. VA01A, M969 HQ rel. 5.1 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON M969 HQ Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEFC969 (or SIEFL87B), Dmax=3.00, Contrast=4, Density=14 n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 293: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens Fluorospot Compact with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQT

Keypad

SPDI

Siemens 37-pinData Cable

SiemensFluorospot Compact

3 M H Q L a s e r I m a g e r

Video Cable for Footswitch

Requirements: Fluorospot Compact rel. VA01A, M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0. Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. M969 HQT Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMS, Contrast=15, Density=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 294: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Siemens Fluorospot Compact with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

KEIB

XL Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

3M L a ser I m ag er

Footswitch

Video Cable for Footswitch

Requirements: Fluorospot Compact rel. VA01A, M959 XL rel. 3.8 Note: a footswitch possibility is available with VA01A Fluoro Compact sw release. Setup: n on XL Control Panel set Density & Contrast depending on chemistry n on KEIB set Jumper=RS422 n on XL Input Module install LUT 322A0 M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Parity=Enable Even, Timeout=30, T6=255, T7=200, T10=200

Page 295: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens Fluorospot Compact with Kodak DryView 8100 LASER IMAGER

Copper Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

DryView 8100

Imager

RS422 9-pole Plug

Requirements: Fluoro Compact version 3 rel. VC00C, 8100 v2.4.1 Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=2, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=75, Transmission rate=0 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=30, P1,…,P6=0

n on IMAGE QLTY-> Pixel Correct=On, 952 Override=2 n on IMAGE QUALITY-> TFT FILES Menu: TFT=SIEFL87B n on LOCAL PANEL Menu: Contrast=4, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Even, Timeout=60

Page 296: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Fluorospot Compact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual, and HQ)

DPCCopper Cable

DPI4 Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

Siemens Fluorospot Compact

Kodak DryView 8700 Plus

3M 8700 DryView

Fiber Cable

Fiber Cable

DPC-to-UKEIB Cable

Kodak 9410 PACS Link

Requirements: Fluoro Compact version 3 rel. VC00C, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers.

Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Page 297: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=30, Parity=Even, Memory=7 n Serial Port: Protocol=SuperSet, Parity=None, Baud Rate=19200

on Device Setup, IMS KEYPADS: n Kpad=flc, Hosp=sms, Serial Port=DPI4 A KPAD, Image Card=DPI4 A DATA n Available Printers=8700, Film Destination=Processor, TFT/ULUT=Siefl87b.w87 n into Defaults: Dest=8700, Size=14x17, C=4, D=14, Dmax=3.0, Bit=8 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 298: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Fluorospot Compact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensFluorospot Compact

Kodak DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

Kodak 9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Requirements: Fluoro Compact version 3 rel. VC00C, 9410 v1.6, 8100 v2.4.1 Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=30, Parity=Even, Memory=7 n Serial Port: Protocol=SuperSet, Parity=None, Baud Rate=19200

on Device Setup, IMS KEYPADS: n Kpad=flc, Hosp=sms, Serial Port=DPI4 A KPAD, Image Card=DPI4 A DATA n Available Printers=8100, Film Destination=Processor, TFT/ULUT=Siefl87b.w87 n into Defaults: Dest=8100, Size=14x17, C=4, D=14, Dmax=3.0, Bit=8

Page 299: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 300: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Fluorospot Compact with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospot Compact

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Requirements: Fluorospot Compact rel. VB00A Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot Compact DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=flc, n Primary Control Type=Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=880, Lines=880, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0

Page 301: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELI 160, Media Size Select=35x43

n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=4.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

160 Setup: no modality-specific setup needed

Page 302: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Fluorospot Compact with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospot Compact

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Fiber Cable

Requirements: Fluorospot Compact rel. VB00A Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot Compact DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=flc, n Primary Control Type=Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=880, Lines=880, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 303: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELP 2180, Media Size Select=35x43

n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=4.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 304: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Fluorospot Compact with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospot Compact

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Fiber Cable

Requirements: Fluorospot Compact VB00A Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot Compact DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=flc, n Primary Control Type=Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=880, Lines=880, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On

Page 305: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELP 1120, Media Size Select=35x43

n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=4.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 306: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Fluorospot Compact with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Keypad

SiemensFluorospot Compact

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

Fiber Cable

3M8700DryView

Kodak DryView 8700 Plus

SPDI

Siemens 37-pinData Cable

RS422 37-to-50 pinDigital Adaptor Cable

Requirements: Fluoro Compact version 3 rel. VC00C Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM 200 Destinations.

Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot Compact DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=flc, n Primary Control Type=Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=880, Lines=880, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Page 307: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=4 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Siefl87b.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 308: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

Fluorospot Compact with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Keypad

SiemensFluorospot Compact

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

RS4229-pole Plug

Kodak DryView 8100

SPDI

Siemens 37-pinData Cable

RS422 37-to-50 pinDigital Adaptor Cable

Requirements: Fluoro Compact version 3 rel. VC00C Requirements: MIM200 v6.1, 8100 v2.4.1 Note: a footswitch possibility is available. Fluorospot Compact Setup: n into Set, Service icon, password, select: Spdi Settings n set: Request Timeout=5, Manual=Yes (note: if footswitch available then Manual=No) n Parity=Even, LUT=No, Auto Mode=85, Transmission rate=0 MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot Compact DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=flc, n Primary Control Type=Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=880, Lines=880, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 309: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=4 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Siefl87b.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 310: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Fluorospot Compact via DICOM with Kodak DryView 8300 LASER IMAGER

SiemensFluorospot Compact

DryView 8300

DICOM Network

Requirements: Fluorospot Compact rel. VD10A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=DV8300 and in Network Settings set: n AET=IMN_8300, Host name=DV8300, IPAddr=accordingly, Port=104 n Create New and set: Camera=Imation_gen n set: Size=8INx10IN, Format=1x1,1x2,2x2 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=4, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set:

n Modality Group=2

Page 311: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

Fluorospot Compact via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

SiemensFluorospot Compact

DICOM Network

Kodak 190 camera

Requirements: Fluorospot Compact rel. VD10A Requirements: 190 rel. 1.7.29 Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K190 and in Network Settings set: n AET=190, Host name=K190, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 312: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Fluorospot Compact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

SiemensFluorospot Compact

8700 Plus

9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Fluorospot Compact rel. VD10A, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers

Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=DV8700 and in Network Settings set: n AET=9410, Host name=DV8700, IPAddr=accordingly, Port=1024 n Create New and set: Camera=Imation_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

Page 313: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=15, TFT/ULUT=Siefl87b.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 314: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

Fluorospot Compact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

SiemensFluorospot Compact

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Fluorospot Compact rel. VD10A, 9410 v1.6, 8100 v2.4.1 Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=DV8100 and in Network Settings set: n AET=9410, Host name=DV8100, IPAddr=accordingly, Port=1024 n Create New and set: Camera=Imation_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=15, TFT/ULUT=Siefl87b.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down

Page 315: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 316: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

Fluorospot Compact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

SiemensFluorospot Compact

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Fluorospot Compact rel. VD10A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=DV8300 and in Network Settings set: n AET=9410, Host name=DV8300, IPAddr=accordingly, Port=1024 n Create New and set: Camera=Imation_gen n set: Size=8INx10IN, Format=1x1,1x2,2x2 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8300, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=4, TFT/ULUT=693c0.w8u n Max.Density=300, Border=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto

Page 317: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 318: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

SiemensFluorospot Compact

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, KELI 160 v7.2 Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K160 and in Network Settings set: n AET=160, Host name=K160, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 319: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=4 i.e., 575 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 320: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

SiemensFluorospot Compact

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200 Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, 2180 rel. 2.17H Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K2180 and in Network Settings set: n AET=2180, Host name=K2180, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On

Page 321: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=4 i.e., 575 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 322: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

SiemensFluorospot Compact

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K1120 and in Network Settings set: n AET=1120, Host name=K1120, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On

Page 323: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=4 i.e., 575 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 324: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

SiemensFluorospot Compact

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K8200 and in Network Settings set: n AET=8200, Host name=K8200, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Page 325: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 326: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

SiemensFluorospot Compact

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination

Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K8700 and in Network Settings set: n AET=8700, Host name=K8700, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Page 327: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 328: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

SiemensFluorospot Compact

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=K8100 and in Network Settings set: n AET=8100, Host name=K8100, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Kodak_gen n set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On

Page 329: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Siefl87b.w87 (Always=Y), Contrast (dry)=15 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 330: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

Fluorospot Compact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

SiemensFluorospot Compact

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Fluorospot Compact rel. VD10A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Fluorospot Compact Setup: n into Service select: Set, Configuration, Dicom Print Settings n set Alias=DV8300 and in Network Settings set: n AET=8300, Host name=DV8300, IPAddr=accordingly, Port=5040 n Create New and set: Camera=Imation_gen n set: Size=8INx10IN, Format=1x1,1x2,2x2 n set: Own Print AET=e.g., FLC_PRINT_SCU and Retry=0 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On

Page 331: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=693c0.w8u (Always=Y), Contrast (dry)=4 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 332: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

Fluorospot Compact via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Fluorospot Compact rel. VD10A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Fluorospot Compact Setup: - into Service select: Set, Configuration, Dicom Print Settings - set Alias=K8900 and in Network Settings set: - AET=8900, Host name=K8900, IPAddr=accordingly, Port=5040 - Create New and set: Camera=Kodak_gen - set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 - set: Own Print AET=eg FLC_PRINT_SCU and Retry=0 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0

SiemensFluorospot Compact

DICOM Network

Kodak DryView 8900

Page 333: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Siefl87b.w87 (Always=Y) n Contrast= 15 (Always=Y), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=flc

Page 334: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

Fluorospot Compact via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Fluorospot Compact rel. VD10A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Fluorospot Compact Setup: - into Service select: Set, Configuration, Dicom Print Settings - set Alias=K8150 and in Network Settings set: - AET=DV8150, Host name=K8150, IPAddr=accordingly, Port=5040 - Create New and set: Camera=Kodak_gen - set: Size=14INx17IN, Format=1x1,1x2,2x2,2x3,3x3,3x4,3x5,4x4,4x5 - set: Own Print AET=eg FLC_PRINT_SCU and Retry=0 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2

SiemensFluorospot Compact

DICOM Network

Kodak DryView 8150

Page 335: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10 n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify:

n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name= Siefl87b.w87 (Always=Y) n Contrast=15 (Always=Y), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=flc

Page 336: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

Fluorospot Compact via DICOM with Kodak Color Medical Imager 1000

Requirements: Fluorospot Compact rel. VD10A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Fluorospot Compact Setup: - into Service select: Set, Configuration, Dicom Print Settings - set Alias=CMI1000 and in Network Settings set: - AET=CMI1000, Host name=CMI1000, IPAddr=accordingly, Port=5040 - Create New and set: Camera=Imation_gen - set: Size=8INx10IN, Format=1x1,1x2,2x2 - set: Own Print AET=eg FLC_PRINT_SCU and Retry=0 CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=15 (Always=Y) n TFT Set (From list)=Siefl87b.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=N), Polarity=Positive (Always=N)

DICOM Network

Kodak CMI 1000

SiemensFluorospot Compact

Page 337: Siemens Setup Manuals

Siemens DSA Fluorospot Compact with LASER IMAGER Products

Author: [email protected], Edition: May ´05 56

n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 338: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for Siemens DSA Fluorospot H with LASER IMAGERS (old Siemens modality, no more in production) Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer ..................................................... 2 n Kodak DryView 8700 LASER IMAGER / Plus................................................................. 3 n Kodak DryView 8700 LASER IMAGER / Standard ......................................................... 4 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer ..................................................... 5 n Kodak DryView 8500 LASER IMAGER / Plus ................................................................. 6 n Kodak DryView 8500 LASER IMAGER / Standard ......................................................... 7 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer ..................................................... 8 n Kodak DryView 8300 LASER IMAGER / Standalone ...................................................... 9 n Kodak Digital Science 969 HQ LASER IMAGER ....................................................... 10 n Kodak Digital Science 969 HQT LASER IMAGER..................................................... 11 n Kodak Digital Science 959 XL LASER IMAGER ........................................................ 12 n Kodak DryView 8100 LASER IMAGER.......................................................................... 13 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ).......... 14 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8100 LASER IMAGER.......................................................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 160 LASER IMAGER........................................................................... 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 2180 LASER PRINTER........................................................................ 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) /

Kodak Ektascan 1120 LASER PRINTER........................................................................ 22 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) ..... 24 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4) ..................................................................... 26 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8900 LASER IMAGER ......................................................................... 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0.

Page 339: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Siemens Fluorospot H with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8700 DualFiber Cable

3M 8700 DryView

3M8800Mul ti- Input Manager

Requirements: SHPT rel. 1.3, 8800 rel. 4.2, 8700 rel. 1.15 Setup: n on Siemens Fluoro-H install Camera Config.File DRYVIEW (if not available HQ) n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=XL, Timeout=30 n on SHPT set Density=14 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n TFT=SIEFL87B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2

n on EIB Menu: Parity=Disable, Timeout=30

Page 340: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

Siemens Fluorospot H with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostSPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8700 Plus

3M 8700 DryView

Requirements: 8700 rel. 1.15 Setup: n on Siemens Fluoro-H install Camera Config.File DRYVIEW (if not available HQ) n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8700 Plus Setup: n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Fluoro-H, Timeout=30, Smooth Beta=2, Sharp Beta=2 n on IMAGE Menu:

n TFT=SIEFL87B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=30

Page 341: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

Siemens Fluorospot H with Kodak DryView 8700 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8700 Standard

3M8700 DryView

Requirements: 8700 rel. 1.15 Setup: n on Siemens Fluoro-H install Camera Config.File DRYVIEW (if not available HQ)

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8700 Standard Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Right n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Fluoro-H, Timeout=30, Smooth Beta=2, Sharp Beta=2 n on IMAGE Menu:

n TFT=SIEFL87B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=30

Page 342: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

Siemens Fluorospot H with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8500 DualFiber Cable

3M 8700 DryView 3M8800Mult i- Input Manager

Requirements: SHPT rel. 1.3, 8800 rel. 5.1, 8500 rel. 1.22 Setup: n on Siemens Fluoro-H install Camera Config.File HQ n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=HQ, Timeout=30 n on SHPT set Density=14 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n TFT=SIEFL87B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2

n on EIB Menu: Parity=Disable, Timeout=30

Page 343: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Siemens Fluorospot H with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8500 Plus

3M 8700 DryView

Requirements: SHPT rel. 1.3, 8500 rel. 1.22 Setup: n on Siemens Fluoro-H install Camera Config.File HQ n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=HQ, Timeout=30 n on SHPT set Density=14 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8500 Plus Setup: n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEFL87B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2

n on SYSTEM Menu: n Memory Management=Best Fit

n on EIB Menu: n Parity=Disable, Timeout=30

Page 344: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

Siemens Fluorospot H with Kodak DryView 8500 LASER IMAGER / Standard

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8500 Standard

3M8700DryView

Imager

Requirements: SHPT rel. 1.3, 8500 rel. 1.22 Setup: n on Siemens Fluoro-H install Camera Config.File HQ n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=HQ, Timeout=30 n on SHPT set Density=14 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Center n on COMM Menu: 959 Default n on IMAGE Menu:

n TFT=SIEFL87B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2

n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=30

Page 345: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

Siemens Fluorospot H with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

DEIB Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB 37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

RS232 25-to-9 pin Host Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

Keypad Siemens 25-pin Control Cable

Siemens 37-pin Data Cable

Siemens Fluorospot H

Requirements: SHPT rel. 1.3, 8800 rel. 5.1, 8300 rel. 4.4 Setup: n on Siemens Fluoro-H install Camera Config.File HQ n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=HQ, Timeout=30 n on SHPT set Density=15 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial: Baud=1200, Data=8, Stop=1, Parity=Even, Protocol=3M n Digital Interface: Parity=None, Modality Group=2

8800 Setup: n on COMM Menu: 959 Default n on IMAGE Menu: Density=15, Contrast=4 n on HOST Menu:

n Pixel CorreCtion=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2

n on EIB Menu: Parity=Disable, Timeout=30

Page 346: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

Siemens Fluorospot H with Kodak DryView 8300 LASER IMAGER / Standalone

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

ImagerHost

Siemens Host Protocol Translator

RS422 9-pinCopper Cable

SPCI

SPDI

Keypad

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8300

Requirements: SHPT v1.3, 8300 v4.6, 8300 LUT v3.0.3 Note: in case no Pritzel Boxes are used between Fluorospot-H and 8300 (ie direct copper

digital Data Cable from Fluorospot-H cabinet to 8300 digital Input Module), then use a short digital Data Cable between Fluorospot-H and 8300 (eg 10mt. max) for image transfer to avoid image acquisition problems.

Setup: n on Siemens Fluoro-H install Camera Config.File HQ n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=HQ, Timeout=30 n on SHPT set Density=15 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8300 Setup: n on 8300 Operator Menu set: D=15, C=4, Sharp/Smooth=0 ie Auto n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Delimiter=Comma, Protocol=3M

n Digital Interface: Parity=None, Modality Group=2

Page 347: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

Siemens Fluorospot H with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

3 M H Q L a s e r I m a g e r

Requirements: SHPT rel. 1.3, HQ rel. 4.2 Setup: n on Siemens Fluoro-H install Camera Config.File HQ n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=HQ, Timeout=30 n on SHPT set Density=14 and Contrast=4 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n TFT=SIEFL8B (or SIEFL87C), Dmax=3.00, Contrast=4, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu: Parity=Disable, Timeout=30

Page 348: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

Siemens Fluorospot H with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQT

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

3 M H Q L a s e r I m a g e r

Requirements: M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 Setup: n on Siemens Fluoro-H install Camera Config.File HQ

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

M969 HQT Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Right n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Fluoro-H, Timeout=30 n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMS, Contrast=15, Density=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=30

Page 349: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

Siemens Fluorospot H with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

3 M L a se r I ma g er

Requirements: SHPT rel. 1.3, XL rel. 3.8 Setup: n on Siemens Fluoro-H install Camera Config.File XL n on SHPT Service Screen set Modality=Fluoro-H,Camera Type=XL, Timeout=30 n on SHPT set Density & Contrast depending on chemistry n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n on XL Input Module install LUT 322A0

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Parity=Disable, Timeout=30

Page 350: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

Siemens Fluorospot H with Kodak DryView 8100 LASER IMAGER

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

DryView 8100

Imager

RS422 9-pole Plug

Requirements: SHPT v1.3, 8100 v1.1 Setup: n on Siemens Fluoro-H install Camera Config.File DRY_VIEW (if not available HQ) n on SHPT Service Screen set Modality=Fluorospot, Camera Type=XL, Timeout=30 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n on SHPT set Density=14 and Contrast=9 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=30, P1,…,P6=0

n on IMAGE QUALITY-> TFT FILES Menu: TFT=SIEPOLY n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=Off n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Disable

Page 351: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 14

Siemens Fluorospot H via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

8700 Plus

3M8700DryView

Fiber Cable

Fiber Cable

DPC-to-UKEIB Cable

9410 PACS Link

Requirements: SHPT v1.3, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers. Setup: n on Fluorospot H install Camera Config.File DRYVIEW (if not available HQ) n on SHPT set: Contrast=4, Density=14 n on SHPT Service Screen set Modality=Fluoro-H, Camera=XL, Timeout=30 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 352: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 15

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=30, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=flH, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8700, Film Destination=Processor, Printer1=8700(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Siefl87b.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Dest.=Printer 1, Media Size=14x17, C=4, D=14 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 353: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 16

Siemens Fluorospot H via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot H

DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Requirements: SHPT v1.3, 9410 v1.6, 8100 v2.4.1 Setup: n on Siemens Fluoro-H install Camera Config.File DRYVIEW (if not available HQ) n on SHPT set: Contrast=4, Density=14 n on SHPT Service Screen set Modality=Fluoro-H, Camera=XL, Timeout=30 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 354: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 17

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=30, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=flH, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8100, Film Destination=Processor, Printer1=8100(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Siefl87b.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=4, D=14 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 355: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 18

Fluorospot H via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensFluorospot H

Requirements: MIM 200 v6.1, KELI 160 v7.2 Fluoro-H Setup: on Siemens Fluoro-H install Camera Config.File XLP MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot H DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sieflh, n Mod.Name=flh, Primary Control: Type=Siemens FSPOT, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0

Page 356: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 19

n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 357: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 20

Fluorospot H via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensFluorospot H

Requirements: MIM 200 v6.1, KELP 2180 v2.17H Fluoro-H Setup: on Siemens Fluoro-H install Camera Config.File XLP MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot H DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sieflh, n Mod.Name=flh, Primary Control: Type=Siemens FSPOT, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 358: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 21

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 359: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 22

Fluorospot H via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensFluorospot H

Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Fluoro-H Setup: on Siemens Fluoro-H install Camera Config.File XLP MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot H DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sieflh, n Mod.Name=flh, Primary Control: Type=Siemens FSPOT, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 360: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 23

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 361: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 24

Fluorospot H via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospot H

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Fiber Cable

3 M 8700 DryView

Kodak DryView 8700 Plus

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM 200 Destinations and if HQ by installing HQ into Siemens Camera Config.File

Fluoro-H Setup: on Fluoro-H install Camera Config.File DRYVIEW (if not available HQ) MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot H DF:

n Board/Channel=Digital Board 1 Channel 1, Logical Name=flH, n Mod.Name=flH, Primary Control: Type=3M - FSPOT, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=2, Interpolation Smooth=2

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Page 362: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 25

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=4 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Siefl87b.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 363: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 26

Fluorospot H via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospot H

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable25-to-25 Null

Modem Cable COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

Kodak DryView 8100

RS4229-pole Plug

Requirements: MIM200 v6.1, 8100 v2.4.1 Fluoro-H Setup: on Fluoro-H install Camera Config.File DRYVIEW (if not available HQ) MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot H DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=flH, n Mod.Name=flH, Primary Control: Type=3M - FSPOT, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=2, Interpolation Smooth=2 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On

Page 364: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 27

n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=4 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Siefl87b.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 365: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 28

Fluorospot H via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8900 LASER IMAGER

Requirements: Fluorospot-H rel. VE10, MIM 200 v6.1 Requirements: 8900 release 2.0 (ie DRE v2.00.b3, MIM v5.6.b3, MCS v2.00) Fluoro-H Setup: on Siemens Fluoro-H install Camera Config.File Kodak 2180 MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

ie delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=eg MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot H DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name= sieflh, n Mod.Name=flh, Primary Control: Type=Siemens FSPOT, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Network, Qualified, 8900, Set: n General: Log.Name=8900, IPAddr=accordingly n General: Database=8900, Model=8900, Memory=32 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n DICOM Info: Protocol=DICOM 3.0, Service Class=Basic Grayscale Print n DICOM Info: Port=5040,AETitle=NER_8900,Counter=40,Response=100 n Supported Items: Collation=On, Common Text=On, Tonescaling=On n Supported Items: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnif=On, Bilinear=On, Replic=On, Cubic Spline=On n Interpolation: Cubic Convolution 2=On, Cubic Convolution 3=On

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

25-to-25 NullModem Cable

SiemensFluorospot H

Kodak DryView 8900

DICOM Network

Page 366: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 29

n Format Types: Custom Formats=On, Row Symm.=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.3 n SCU: Luminance Space= On, Variable Border Density=On n SCU: Curve Shape=On, Perception LUT =On, PLUT Service=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination= 8900, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=15 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Siefl87b.w87, Auto Study=Off, Console=On, Annotation=Off

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On

Page 367: Siemens Setup Manuals

Siemens DSA Fluorospot H with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 30

n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Siefl87b.w87 (Always=Y) n Contrast= 15 (Always=Y), Smoothing Type=2 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=Y) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=fH

Page 368: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGERS (note: different models of Iconos, Siregraph, Sireskop could have either the setup of Fluorospot TOP or the setup of Fluorospot Compact)

Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer ................................ ................................ ............ 3 n Kodak DryView 8700 LASER IMAGER / Plus................................ ................................ ......................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ................................ ................................ ................. 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer ................................ ................................ ............ 6 n Kodak DryView 8500 LASER IMAGER / Plus................................ ................................ ......................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ................................ ................................ ................. 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer ................................ ................................ ............ 9 n Kodak DryView 8300 LASER IMAGER / Standalone ................................ ................................ .............. 10 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer / Kodak DryView 8300 LASER IMAGER / Dual Printer ................................ ................................ ............ 11

n Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8700 LASER IMAGER / Dual Printer / Kodak DryView 8500 LASER IMAGER / Dual Printer ................................ ................................ ............ 13

n Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8500 LASER IMAGER / Dual Printer / Kodak DryView 8300 LASER IMAGER / Dual Printer ................................ ................................ ............ 14

n Kodak Digital Science 969 HQ LASER IMAGER................................ ................................ ................ 16 n Kodak Digital Science 969 HQT LASER IMAGER ................................ ................................ ............. 17 n Kodak Digital Science 959 XL LASER IMAGER ................................ ................................ ................ 18 n Kodak DryView 8100 LASER IMAGER................................ ................................ ................................ ... 19 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ ) ................................ .............................. 21

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8100 LASER IMAGER................................ ................................ ................................ ... 23

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 160 LASER IMAGER ................................ ................................ ................................ .... 25

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 2180 LASER PRINTER ................................ ................................ ................................ . 27

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 1120 LASER PRINTER ................................ ................................ ................................ . 29

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4) ................................ ......................... 31

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4)................................ ................................ .............................. 33

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v6.1, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 369: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER..................................................................................... 35 n Kodak Digital Science 190 MEDICAL LASER PRINTER .................................................... 36 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)................................................ 37

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8100 LASER IMAGER..................................................................................... 39

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8300 LASER IMAGER..................................................................................... 41

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 160 LASER IMAGER...................................................................................... 43

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 2180 LASER PRINTER ................................................................................... 45

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 1120 LASER PRINTER ................................................................................... 47

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)..................................................................... 49

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ..................................... 51

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5)....................................................................... 53

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5)....................................................................... 55

n Kodak DryView 8900 LASER IMAGER..................................................................................... 57 n Kodak DryView 8150 LASER IMAGER..................................................................................... 59 n Kodak Color Medical Imager 1000............................................................................................. 61

Page 370: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens Fluoro-TOP VB14 with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-Input Manager

Requirements: Fluoro TOP rel. VB14, SHPT rel. 1.3, 8800 rel. 5.1, 8700 rel. 1.22

Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear

Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_DV8700 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8700 Dual Setup: n on COMM Menu:

n 959 Default n on IMAGE Menu:

n if a) images to cam=lin, TFT=SIEFL87B, set at SHPT: C=4, D=14 n if b) images to cam=non-lin, TFT=SIEWS87B, Dmax=3.00, C=2, D=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on EIB Menu: Parity=Enable Even, Timeout=75

Page 371: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens Fluoro-TOP VB14 with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostSPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8700 Plus

3M 8700 DryView

Requirements: Siemens Fluoro TOP rel. VB14, 8700 Plus rel. 1.15 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_DV8700 n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8700 Plus Setup: n on COMM Menu: Siemens Default n on SIEMENS Menu: Modality=Sienet, Timeout=75 n on IMAGE Menu:

n if a) images to cam=lin, TFT=SIEFL87B, Dmax=3.00, C=4, D=14 n if b) images to cam=non-lin, TFT=SIEWS87B, Dmax=3.00, C=2, D=14

n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even, Timeout=75

Page 372: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Siemens Fluoro-TOP VB14 with Kodak DryView 8700 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8700 Standard

3M 8700 DryView

Requirements: Siemens Fluorospot TOP rel. VB14, 8700 Standard rel. 1.15 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_DV8700

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Center n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Sienet, Timeout=75 n on IMAGE Menu:

n if a) images to cam=lin, TFT=SIEFL87B, Dmax=3.00, C=4, D=14 n if b) images to cam=non-lin, TFT=SIEWS87B, Dmax=3.00, C=2, D=14

n on SYSTEM Menu: n Memory Management=Best Fit

n on EIB Menu: n Parity=Enable Even, Timeout=75

Page 373: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens Fluoro-TOP VB14 with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8500 DualFiber Cable

3M 8700 DryView 3M8800 Multi-InputManager

Requirements: Fluoro TOP rel. VB14, SHPT rel. 1.3, 8800 rel. 5.1, 8500 rel. 1.22

Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear

Setup: n on Siemens Fluorospot TOP rel. VB14 install Camera Config.File Imation_DV8500 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n if a) images to cam=lin, TFT=SIEFL87B, set at SHPT: C=4, D=14 n if b) images to cam=non-lin, TFT=SIEWS87B, Dmax=3.00, C=2, D=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on EIB Menu: Parity=Enable Even, Timeout=75

Page 374: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Siemens Fluoro-TOP VB14 with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8500 Plus

3M8700 DryView

Requirements: Fluorospot TOP rel. VB14, SHPT rel. 1.3, 8500 Plus rel. 1.22

Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear

Setup: n on Siemens Fluorospot TOP rel. VB14 install Camera Config.File Imation_DV8500 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8500 Plus Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n if a) images to cam=lin, TFT=SIEFL87B, set at SHPT: C=4, D=14 n if b) images to cam=non-lin, TFT=SIEWS87B, Dmax=3.00, C=2, D=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even, Timeout=75

Page 375: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens Fluoro-TOP VB14 with Kodak DryView 8500 LASER IMAGER / Standard

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8500 Standard

3M 8700 DryView

Imager

Requirements: Fluoro TOP rel. VB14, SHPT rel. 1.3, 8500 Standard rel. 1.22

Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear

Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_DV8500 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Center n on COMM Menu: 959 Default n on IMAGE Menu:

n if a) images to cam=lin, TFT=SIEFL87B, set at SHPT: C=4, D=14 n if b) images to cam=non-lin, TFT=SIEWS87B, Dmax=3.00, C=2, D=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even, Timeout=75

Page 376: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Siemens Fluoro-TOP VB14 with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

3M8800Multi-InputM

anager

Requirements: Fluoro TOP rel. VB14, SHPT rel. 1.3, 8800 rel. 5.1 Requirements: 8300 rel. 4.6, 8300 LUT rel. 2.0.0

Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear

Setup: n on Siemens Fluorospot TOP rel. VB14 install Camera Config.File Imation_DV8300 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n if a), set at SHPT: Contrast=4, Density=15

8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: 1200, 8, 1, Even, Protocol=3M n Digital Interface: Parity=None, if a) Modality Group=2, if b) Modality Group=4

8800 Setup: n on COMM Menu: 959 Default n on IMAGE Menu: Density=15, Contrast=4

n on EIB Menu: Parity=Enable Even, Timeout=75

Page 377: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens Fluoro-TOP VB14 with Kodak DryView 8300 LASER IMAGER / Standalone

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

ImagerHost

Siemens Host Protocol Translator

RS422 9-pinCopper Cable

SPCI

SPDI

Keypad

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8300

Requirements: Siemens Fluorospot TOP rel. VB14, SHPT rel. 1.3 Requirements: 8300 rel. 4.6, 8300 LUT rel. 2.0.0 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluorospot TOP rel. VB14 install Camera Config.File Imation_DV8300 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n if a), set at SHPT: Contrast=4, Density=14

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=Even n if a) set Modality Group=2, if b) set Modality Group=4

Page 378: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Siemens Fluoro-TOP VB14 with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer / Kodak DryView 8300 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8300 Dual

Fiber Cable

3M8800Multi-InputM

anager

3M8700DryView

8700 Dual

Fiber Cable

POEIB

9-to-9-pin Copper Cable

37-pin Digital Cable

Requirements: Fluoro TOP VB14, SHPT 1.3, 8800 v.5.1, 8700 v.1.22 Requirements: 8300 rel. 4.6, 8300 LUT rel. 2.0.0 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_MIM8800 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n if a), set at SHPT: Contrast=4, Density=15

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

Page 379: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n if a) set Modality Group=2, if b) set Modality Group=4

8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n if a), set TFT=SIEFL87B, set at SHPT: Contrast=4, Density=14 n if b), set TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on EIB Menu: Parity=Enable Even, Timeout=75

Page 380: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Siemens Fluoro-TOP VB14 with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer / Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8700 DualFiber Cable

3M 8700 DryView

3M8800 Multi-Input Manager

3M 8700 DryView

8500 Dual

Fiber Cable

Requirements: Fluoro TOP VB14, SHPT 1.3, 8800 v.5.1, 8700 v.1.22, 8500 v.1.22 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_MIM8800 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8800/8700 Dual/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: if a), set TFT=SIEFL87B, set at SHPT: C=4, D=14 n on IMAGE Menu: if b), set TFT=SIEWS87B, Dmax=3.00, C=2, D=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on EIB Menu: Parity=Enable Even, Timeout=75

Page 381: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens Fluoro-TOP VB14 with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer / Kodak DryView 8300 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8300 Dual

Fiber Cable

3M8800Multi-InputM

anager

3M8700DryView

8500 Dual

Fiber Cable

POEIB

9-to-9-pin Copper Cable

37-pin Digital Cable

Requirements: Fluoro TOP VB14, SHPT 1.3, 8800 v.5.1, 8500 v.1.22 Requirements: 8300 rel. 4.6, 8300 LUT rel. 2.0.0 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_MIM8800 n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n if a), set at SHPT: Contrast=4, Density=15

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

Page 382: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n if a) set Modality Group=2, if b) set Modality Group=4

8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu:

n if a), set TFT=SIEFL87B, set at SHPT: Contrast=4, Density=14 n if b), set TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=0

n on EIB Menu: Parity=Enable Even, Timeout=75

Page 383: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Siemens Fluoro-TOP VB14 with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

3 M H Q L a s e r I m a g e r

Requirements: Flurospot TOP rel. VB14, SHPT rel. 1.3, M969 HQ rel. 5.1 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluorospot TOP rel. VB14 install Camera Config.File Imation_M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQ Setup: n on COMM Menu:

n 959 Default n on IMAGE Menu:

n if a), set TFT=SIEFC969 (or SIEFL87B), set at SHPT: C=4, D=14 n if b), set TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14

n on HOST Menu: n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes

n on EIB Menu: n Parity=Enable Even, Timeout=75

Page 384: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Siemens Fluoro-TOP VB14 with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQT

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

3 M H Q L a s e r I m a g e r

Requirements: Fluoro TOP rel. VB14, M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0. Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_M969_HQ

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQT Setup: n on TDB/C board: Jumpers=RS232, Switch=Center n on COMM Menu: Siemens Default n on SIEMENS Menu: Modality=Sienet, Timeout=75 n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n if a), TFT=PMS, C=15, D=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even, Timeout=75

Page 385: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Siemens Fluoro-TOP VB14 with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

3M L aser I m ag er

Requirements: Siemens Fluoro TOP rel. VB14, SHPT rel. 1.3, M959 XL rel. 3.8 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_M959_XL n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n if a), on SHPT set Density & Contrast depending on chemistry n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n on XL Input Module install LUT 322A0

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Parity=Enable Even, Timeout=75

Page 386: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Siemens Fluorospot TOP VB14 with Kodak DryView 8100 LASER IMAGER

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

DryView 8100

Imager

RS422 9-pole Plug

Requirements: Siemens Fluoro TOP rel. VB14, SHPT v1.3, 8100 v1.1 Note: Fluoro-TOP VB14 could be configured with: a) edit/parameter/update/images to camera=linear b) edit/parameter/update/images to camera=non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera, in

this case use Dmax=300, C=4, TFT=SIEFL87B d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density,

LUT into Camera, then in this case use Dmax=300, C=2, TFT=WRKSTN2A. Note: Fluoro-TOP VB14 could be with: edit/parameter/update/Optimize Image set to Yes or No n if Optimize Image=No image sent from F-TOP to camera is always 20 Meg n if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Setup: n on Siemens Fluoro TOP rel. VB14 install Camera Config.File Imation_DV8700 n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n in case of a) on SHPT set Contrast=4, Density=14 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 387: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=75, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=a) SIEFL87B or b) WRKSTN2A n on LOCAL PANEL: Contrast=a) 4 or b) 2, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4096 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Even

Page 388: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Fluoro-TOP via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

8700 Plus

3M8700 DryView

Fiber Cable

Fiber Cable

DPC-to-UKEIB Cable

9410 PACS Link

Requirements: Fluorospot TOP VB14A, SHPT v1.3, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into Fluorospot TOP Camera Config.File

Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP

Page 389: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, C=4, TFT=SIEFL87B d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then in this case use Dmax=300, C=2, TFT=WRKSTN2A

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Setup: n on Siemens Fluoro TOP rel. VB14A install Camera Config.File Imation_DV8700 n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n in case of a) on SHPT set Contrast=4, Density=14 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=75, Parity=Even, Memory=22 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=flTOP, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8700, Film Destination=Processor, Printer1=8700(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87, Multi-Printer Resp.=Off n Autoswitching=Off, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Dest.=Printer 1, Media Size=14x17, C=a) 4 or b) 2, D=14 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Density=14, Dmax=3.00, Contrast=6 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 390: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Fluorospot TOP via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Fluorospot TOP

DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Requirements: Fluorospot TOP VB14A, SHPT v1.3, 9410 v1.6, 8100 v2.4.1 Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, C=4, TFT=SIEFL87B d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then in this case use Dmax=300, C=2, TFT=WRKSTN2A

Page 391: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Setup: n on Fluoro TOP install Camera Config.File Imation_DV8700 (or if problems XL_959) n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n in case of a) on SHPT set Contrast=4, Density=14 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=75, Parity=Even, Memory=22 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=flTOP, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8100, Film Destination=Processor, Printer1=8100(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87, Multi-Printer Resp.=Off n Autoswitching=Off, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Dest.=Printer 1, Media Size=14x17, C=a) 4 or b) 2, D=14 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 392: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Fluorospot TOP via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensFluorospotTOP

Requirements: Fluorospot TOP VB14A Requirements: MIM 200 v6.1, KELI 160 v7.2 Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then use Dmax=300, Curve Shape=0.0, Film Contrast=0

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Fluoro-TOP Setup: on Fluoro TOP VB14A install Camera Config.File Kodak_190

Page 393: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot TOP DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=ftop, n Mod.Name=ftop, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=Even, Timer=5, Sync=On, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=a) 3.0 or b) 0.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 394: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

Fluorospot TOP via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensFluorospotTOP

Requirements: Fluorospot TOP VB14A Requirements: MIM 200 v6.1, KELP 2180 v2.17H Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then use Dmax=300, Curve Shape=0.0, Film Contrast=0

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Fluoro-TOP Setup: on Fluoro TOP VB14A install Camera Config.File Kodak_2180

Page 395: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot TOP DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=ftop, n Mod.Name=ftop, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=Even, Timer=5, Sync=On, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=a) 3.0 or b) 0.0, Auto Study=Off, Console=On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 396: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Fluorospot TOP via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensFluorospotTOP

Requirements: Fluorospot TOP VB14A Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then use Dmax=300, Curve Shape=0.0, Film Contrast=0

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Fluoro-TOP Setup: on Fluoro TOP VB14A install Camera Config.File Kodak_1120

Page 397: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot TOP DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=ftop, n Mod.Name=ftop, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=Even, Timer=5, Sync=On, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=a) 3.0 or b) 0.0, Auto Study=Off, Console=On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 398: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Fluorospot TOP via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospotTOP

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Fiber Cable

3M 8700 DryView

Kodak DryView 8700 Plus

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: Fluorospot TOP VB14A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM 200 Destinations and in case of 8500 and HQ by installing 8500 and HQ into Fluorospot TOP Camera Config.File.

Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, C=4, TFT=SIEFL87B d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then in this case use Dmax=300, C=2, TFT=WRKSTN2A

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No

Page 399: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Fluoro-TOP Setup: on Fluoro TOP VB14A install Camera Config.File Imation_DV8700 MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot TOP DF:

n Board/Channel=Digital Board 1 Channel 1, Logical Name=ftop, n Mod.Name=ftop, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=Even, Timer=5, Sync=On, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=2, Interpolation Smooth=2

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2 n Film Contrast=a) 4 or b) 2, Image Dmax=3.00, Border=Black, Collation=Off n Auto Print=On, TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Auto Study=Off, Console=On, Annotation=Off

Page 400: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 401: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Fluorospot TOP via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SiemensFluorospotTOP

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable25-to-25 Null

Modem Cable COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

Kodak DryView 8100

RS4229-pole Plug

Requirements: Fluorospot TOP VB14A Requirements: MIM200 v6.1, 8100 v2.4.1 Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/update n Is it a DFR-N with local camera server? yes n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP VB14 could be configured with: a) images to camera linear or b) images to camera non-linear c) if images to camera linear then Image Data not lutted by F-TOP, lutted by Camera

in this case use Dmax=300, C=4, TFT=SIEFL87B d) if images to camera non-linear then Image Data lutted by F-TOP, linear-in-Density

LUT into Camera, then in this case use Dmax=300, C=2, TFT=WRKSTN2A

Note: Fluoro-TOP VB14 could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No Fluoro-TOP Setup: on Fluoro TOP VB14A install Camera Config.File Imation_DV8700 (or if problems XL_959)

Page 402: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Fluorospot TOP DF: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sct, n Mod.Name=sct, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=Even, Timer=5, Sync=On, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=2, Interpolation Smooth=2 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2 n Film Contrast=a) 4 or b) 2, Image Dmax=3.00, Border=Black, Collation=Off n Auto Print=On, TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Auto Study=Off, Console=On, Annotation=Off

Page 403: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 404: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Fluorospot TOP via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens Fluorospot TOP

DryView 8300

DICOM Network

Requirements: Siemens Fluorospot TOP rel. VC01B Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8300 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8300_Dicom, n DICOM services=PRINT_SCP, aet=IMN_8300, port=104, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always aprox 5 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 5 Meg In case any formats-problem appears on F-TOP (e.g., 2:1 not ok), set Optimize Image=No 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set:

n Modality Group=4 (i.e., LUT=linear-in-Density)

Page 405: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Fluorospot TOP via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens Fluorospot TOP

DICOM Network

Kodak 190 camera

Requirements: Fluorospot TOP rel. VC01B Requirements: 190 rel. 1.7.29 Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=K190 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Kodak_190_Dicom, n DICOM services=PRINT_SCP, aet=190, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=0.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 406: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

Fluorospot TOP via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens Fluorospot TOP

8700 Plus

9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Fluorospot TOP rel. VC01B Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and if HQ by installing HQ into Fluoro-TOP DICOM Camera Config.File

Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8700 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8700_Dicom, n DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No 9410 Setup:

Page 407: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

n on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 408: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

Fluorospot TOP via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens Fluorospot TOP

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Fluorospot TOP rel. VC01B Requirements: 9410 v1.6, 8100 v2.4.1 Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8100 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8100_Dicom, n DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No

Page 409: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 410: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

Fluorospot TOP via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens Fluorospot TOP

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Fluorospot TOP rel. VC01B Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8300 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8300_Dicom, n DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always aprox 5 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 5 Meg In case any formats-problem appears on F-TOP (e.g., 2:1 not ok), set Optimize Image=No

Page 411: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=1, TFT/ULUT=wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 412: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens Fluorospot TOP

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Fluorospot TOP rel. VC01B Requirements: MIM200 v6.1, KELI 160 v7.2 Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=K160 Dicom Printer, n modality type=DICOM_PRINTER, n camera type=Kodak_160_Dicom (or Kodak_190_Dicom), n DICOM services=PRINT_SCP, aet=160, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No

Page 413: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 414: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens Fluorospot TOP

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: Fluorospot TOP rel. VC01B Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=K2180 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Kodak_2180_Dicom, n DICOM services=PRINT_SCP, aet=2180, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No

Page 415: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 416: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens Fluorospot TOP

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Fluorospot TOP rel. VC01B Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=K1120 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Kodak_1120_Dicom, n DICOM services=PRINT_SCP, aet=1120, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No

Page 417: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 418: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens Fluorospot TOP

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Requirements: Fluorospot TOP rel. VD10A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: on Fluoro-TOP only a DICOM camera could be installed Note: on Fluoro-TOP Service-CD nbr.7 is present 8200 Camera Config.File Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=K8200 Dicom Printer, n modality type=DICOM_PRINTER, n camera type=Kodak_8200_Dicom (or Kodak_190_Dicom), n DICOM services=PRINT_SCP, aet=8200, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No MIM200 Setup: n on Configure, Network:

Page 419: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 420: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens Fluorospot TOP

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Fluorospot TOP rel. VC01B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: on Fluoro-TOP only a DICOM camera could be installed Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and if HQ by installing HQ into Fluoro-TOP DICOM Camera Config.File

Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8700 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8700_Dicom, n DICOM services=PRINT_SCP, aet=8700, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No

Page 421: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 422: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens Fluorospot TOP

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Fluorospot TOP rel. VC01B Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8100 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8100_Dicom, n DICOM services=PRINT_SCP, aet=8100, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case any formats-problem appears on F-TOP (e.g., 12:1 not ok), set Optimize Image=No MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add:

Page 423: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 56

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 424: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 57

Fluorospot TOP via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens Fluorospot TOP

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Fluorospot TOP rel. VC01B Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: n into Sevice Login (at Unix level), from service menu do sit install: n from main menu do: edit/config/create n node name=kodakd (max 6 chars), component name=DV8300 Dicom Printer, n modality type=DICOM_PRINTER, camera type=Imation_DV8300_Dicom, n DICOM services=PRINT_SCP, aet=8300, port=5040, IPaddr=accordingly n RETURN, exit, exit (i.e., in order to return to main menu) n edit/parameter/update n DICOM Print Camera=kodakd n images to camera=non-linear n optimize matrix size for camera=no n HCC density=300 n exit/exit (i.e., in order to return to main menu) n from main menu do: install/net n exit/exit (i.e., in order to return to main menu) n dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always aprox 5 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 5 Meg In case any formats-problem appears on F-TOP (e.g., 2:1 not ok), set Optimize Image=No

Page 425: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 58

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=wkstn83a.w8u (Always=Y), Contrast (dry)=1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 426: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 59

Fluorospot TOP via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Fluorospot TOP rel. VC01B Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup (using Imation 969 HQ Config.file): - into Sevice Login (at Unix level), from service menu do sit install: - from main menu do: edit/config/create - node name=kodakd (max 6 chars), component name=DV8900 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Imation_969_HQ_Dicom, - DICOM services=PRINT_SCP, aet=8900, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - edit/parameter/update - DICOM Print Camera=kodakd - images to camera=non-linear - optimize matrix size for camera=no - HCC density=300 - exit/exit (ie in order to return to main menu) - from main menu do: install/net - exit/exit (ie in order to return to main menu) - dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case of formats-problem on F-TOP (eg 12:1 not ok), set Optimize Image=No 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

Siemens Fluorospot TOP

DICOM Network

Kodak DryView 8900

Page 427: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 60

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Wrkstn2a.w87 (Always=Y) n Contrast= 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ftop

Page 428: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 61

Fluorospot TOP via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Fluorospot TOP rel. VC01B Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: on Fluoro-TOP only a DICOM camera could be installed Note: on Fluoro-TOP Service-CD nbr.7 is present 8200 Camera Config.File Fluorospot TOP Setup (using Imation 969 HQ Config.file): - into Sevice Login (at Unix level), from service menu do sit install: - from main menu do: edit/config/create - node name=kodakd (max 6 chars), component name=DV8150 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_8200_Dicom, - DICOM services=PRINT_SCP, aet=DV8150, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - edit/parameter/update - DICOM Print Camera=kodakd - images to camera=non-linear - optimize matrix size for camera=no - HCC density=300 - exit/exit (ie in order to return to main menu) - from main menu do: install/net - exit/exit (ie in order to return to main menu) - dfr to return to application and reboot Fluorospot TOP Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always 20 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 20 Meg In case of formats-problem on F-TOP (eg 12:1 not ok), set Optimize Image=No 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications:

SiemensFluorospot TOP

DICOM Network

Kodak DryView 8150

Page 429: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 62

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Wrkstn2a.w87 (Always=Y) n Contrast=1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ftop

Page 430: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 63

Fluorospot TOP via DICOM with Kodak Color Medical Imager 1000

Requirements: Fluorospot TOP rel. VC01B Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on Fluoro-TOP only a DICOM camera could be installed Fluorospot TOP Setup: - into Sevice Login (at Unix level), from service menu do sit install: - from main menu do: edit/config/create - node name=kodakd (max 6 chars), component name=CMI1000 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Imation_DV8300_Dicom, - DICOM services=PRINT_SCP, aet=CMI1000, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - edit/parameter/update - DICOM Print Camera=kodakd - images to camera=non-linear - optimize matrix size for camera=no - HCC density=300 - exit/exit (ie in order to return to main menu) - from main menu do: install/net - exit/exit (ie in order to return to main menu) - dfr to return to application and reboot Fluorospot TOP

Note: Fluoro-TOP could be configured with Optimize Image set to Yes or No: - if Optimize Image=No image sent from F-TOP to camera is always aprox 5 Meg - if Optimize Image=Yes image sent from F-TOP to camera is less or equal 5 Meg In case formats-problem appears on F-TOP (eg 2:1 not ok), set Optimize Image=No CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000

DICOM Network

Kodak CMI 1000

SiemensFluorospot TOP

Page 431: Siemens Setup Manuals

Siemens DSA Fluorospot TOP / Polystar (TOP) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 64

n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=7 (Always=Y) n TFT Set (From list)=Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 432: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGERS Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer ..................................................... 2 n Kodak DryView 8700 LASER IMAGER / Plus ................................................................. 3 n Kodak DryView 8700 LASER IMAGER / Standard ......................................................... 4 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer ..................................................... 5 n Kodak DryView 8500 LASER IMAGER / Plus ................................................................. 6 n Kodak DryView 8500 LASER IMAGER / Standard ......................................................... 7 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer ..................................................... 8 n Kodak Digital Science 969 HQ LASER IMAGER ....................................................... 9 n Kodak Digital Science 969 HQT LASER IMAGER..................................................... 10 n Kodak Digital Science 959 XL LASER IMAGER ........................................................ 11 n Kodak DryView 8100 LASER IMAGER.......................................................................... 12 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1)................................... 13

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1) ..................................................................... 15

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) .................................................................. 17

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4)............................................................... 19

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4)............................................................... 21

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4)................................... 23

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4) ..................................................................... 25

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0.

Page 433: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Siemens HICOR / ACOM with| Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

VEIB with PLL

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

8700 DualFiber Cable

3M 8700 DryView

3M8800Mul ti- Input Manager

Requirements: 8800 rel. 5.1, 8700 rel. 1.22 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8800/8700 Dual Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 434: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

Siemens HICOR / ACOM with Kodak DryView 8700 LASER IMAGER / Plus

VEIB with PLL

Fiber Cable

Fiber Cable

UKEIB

Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

8700 Plus

3M 8700 DryView

Requirements: 8700 Plus rel. 1.22 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8700 Plus Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 435: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

Siemens HICOR / ACOM with Kodak DryView 8700 LASER IMAGER / Standard

Keypad

Video OUTVideo Cable

SiemensHICOR

8700 Standard

3M8700 DryView

Requirements: 8700 Standard rel. 1.22 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=30, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 436: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

Siemens HICOR / ACOM with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer

VEIB with PLL

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

8500 DualFiber Cable

3M 8700 DryView

3M8800Mul ti- Input Manager

Requirements: 8800 rel. 5.1, 8500 rel. 1.22 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8800/8500 Dual Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 437: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Siemens HICOR / ACOM with Kodak DryView 8500 LASER IMAGER / Plus

VEIB with PLL

Fiber Cable

Fiber Cable

UKEIB

Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

8500 Plus

3M 8700 DryView

Requirements: 8500 Plus rel. 1.22 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8500 Plus Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 438: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

Siemens HICOR / ACOM with Kodak DryView 8500 LASER IMAGER / Standard

Keypad

Video OUTVideo Cable

SiemensHICOR

8500 Standard

3M8700 DryView

Requirements: 8500 Standard rel. 1.22 Setup: n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Left n on COMM Menu: 8700 Keypad Default n on IMAGE Menu: TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=30, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 439: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

Siemens HICOR / ACOM with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

VEIB with PLL Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB 37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

Keypad

Video OUT

Keypad

Video Cable

Siemens HICOR

Requirements: 8800 rel. 5.1, 8300 rel. 4.4 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n Modality Group=0

8800 Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n Density=16, Contrast=10 n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 440: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

Siemens HICOR / ACOM with Kodak Digital Science 969 HQ LASER IMAGER

VEIB with PLL

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

3 M H Q L a s e r I m a g e r

Requirements: M969 HQ rel. 5.1 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON M969 HQ Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 441: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

Siemens HICOR / ACOM with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQT

Keypad

Video OUTVideo Cable

SiemensHICOR

3 M H Q L a s e r I m a g e r

Requirements: M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 M969 HQT Setup: n on TDB/C board: Jumpers=RS422, Switch=Left n on COMM Menu: 8700 Keypad Default n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMS, Contrast=15, Density=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=30, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 442: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

Siemens HICOR / ACOM with Kodak Digital Science 959 XL LASER IMAGER

VEIB with PLL

Fiber Cable

Fiber Cable

M959 XL

KEIB

XL Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

3 M L a se r I ma g er

Requirements: M959 XL rel. 3.8 Setup: n on XL Control Panel set Density & Contrast depending on chemistry n on KEIB set Jumper=RS422 n on XL Input Module install LUT 322A0 M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Vert.Del.=70, Image Lines=1092, Horiz.Del.=258, Horiz.Act.=1092 n Clock Delay=3, Fine Pixel Delay=103, Black Level=109 n Pixel Clock Freq.=45, Horiz.Freq.=16-48, Double Gain=0.5-1 n Passes=15, Window Width=3, Retries=2 n Clock Range=44-50, Clocks per Line=1440, Interlaced, Odd

Page 443: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

Siemens HICOR/ACOM with Kodak DryView 8100 LASER IMAGER

Copper Cable

UKEIB

Keypad

Video OUT

Keypad

Video Cable

SiemensHICOR

DryView 8100

Imager

RS422 9-pole Plug

Requirements: 8100 v1.1 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=2 n on IMAGE QUALITY-> TFT FILES Menu: TFT=SIEPOLY n on LOCAL PANEL Menu: Contrast=12, Density=2.90 n on SYSTEM Menu: Acquire=Video n on VIDEO Menu: Parameters as per autosync

aprox Interlace=ON, Image Height=1092, Horiz.Tot=1440, Image Width=1092

Page 444: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

Siemens HICOR / ACOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Copper CableImagraph CardOctopus Cable

UKEIB

Keypad

Video OUT

KeypadSiemens HICOR

DryView 8700 Plus

RS422 CopperConverter Cable

9410 PACS Link

Fiber Cable

Video Cable

Imager

Fiber Cable

3M8700DryView

Requirements: Hicor rel. VA30E, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for

8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers.

Hicor Setup: on Hicor set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, Serial Ports Menu: n COM3: Protocol=SuperSet, Parity=None, Baud Rate=19200

Page 445: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 14

on I/O CARD SETUP, Imagraph Video Menu (aprox): n Vert.Tot=1249, Frame Period=40, Interlace=ON, Vert.Back Porch=71.0 n Image Height=1022, Horiz.Tot=1440, Horiz.Back Sync=310 n Image Width=1024, Horiz.Sync Width=2486, Horiz.Back Porch=297

on Device Setup, IMS KEYPADS: n Kpad=hicor, Hosp=siemens, Serial Port=COM3, Image Card=Imagraph, Ch=A1 n Available Printers=8700, Film Destination=Processor, TFT/ULUT=Siepoly.w87 n into Defaults: Dest=8700, Size=14x17, C=10, D=15, Dmax=3.1, Bit=8 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 446: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 15

Siemens HICOR / ACOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Copper CableImagraph CardOctopus Cable

UKEIB

Keypad

Video OUT

KeypadSiemens HICOR

DryView 8100

Control 9-pin

Data 37 pin

RS422 CopperConverter Cable

9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Video Cable

Imager

Requirements: Hicor rel. VA30E, 9410 v1.6, 8100 v2.4.1 Hicor Setup: n on Hicor set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, Serial Ports Menu: n COM3: Protocol=SuperSet, Parity=None, Baud Rate=19200

on I/O CARD SETUP, Imagraph Video Menu (aprox): n Vert.Tot=1249, Frame Period=40, Interlace=ON, Vert.Back Porch=71.0 n Image Height=1022, Horiz.Tot=1440, Horiz.Back Sync=310 n Image Width=1024, Horiz.Sync Width=2486, Horiz.Back Porch=297

Page 447: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 16

on Device Setup, IMS KEYPADS: n Kpad=hicor, Hosp=siemens, Serial Port=COM3, Image Card=Imagraph, Ch=A1 n Available Printers=8100, Film Destination=Processor, TFT/ULUT=Siepoly.w87 n into Defaults: Dest=8100, Size=14x17, C=10, D=15, Dmax=3.1, Bit=8 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 448: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 17

Siemens HICOR/ACOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Hicor rel. VA30E Requirements: MIM 200 v6.1, KELI 160 v7.2 Hicor Setup: set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input,Direct Conn, Config.Add, Video, Qual.=Hicor/Bicor 1024 50Hz: n Board/Channel=Video60 Board 1 Channel 1, Logical Name= hicor, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n HL=32, HD=22.75, Clk=45, Tot.Pxls=1440, Image Pxls=1024 n HS=2.49, HFP=0, HBP=4.44, HB=0 n Image Lines=1024, Tot.Lines=1248, VBP=70, VS=3, PreE=PostE=3 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On

Keypad

Video CableVideo OUT

SiemensHICOR

Kodak MIM 200

Video CardOctopus Cable

Kpad / Host Control Octopus Adaptor Cable

Kodak 160 cameraCrossedNetwork Cable

Page 449: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 18

n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

160 Setup: no modality-specific setup needed

Page 450: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 19

Siemens HICOR/ACOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Hicor rel. VA30E Requirements: MIM 200 v6.1, KELP 2180 v2.17H Hicor Setup: set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input,Direct Conn, Config.Add, Video, Qual.=Hicor/Bicor 1024 50Hz: n Board/Channel=Video60 Board 1 Channel 1, Logical Name= hicor, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n HL=32, HD=22.75, Clk=45, Tot.Pxls=1440, Image Pxls=1024 n HS=2.49, HFP=0, HBP=4.44, HB=0 n Image Lines=1024, Tot.Lines=1248, VBP=70, VS=3, PreE=PostE=3 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Keypad

Video CableVideo OUT

SiemensHICOR

Kodak MIM 200

Video CardOctopus Cable

Kpad / Host Control Octopus Adaptor Cable

Kodak 2180 camera

Fiber Cable

Page 451: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 20

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 452: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 21

Siemens HICOR/ACOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Hicor rel. VA30E Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Hicor Setup: set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input,Direct Conn, Config.Add, Video, Qual.=Hicor/Bicor 1024 50Hz: n Board/Channel=Video60 Board 1 Channel 1, Logical Name= hicor, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n HL=32, HD=22.75, Clk=45, Tot.Pxls=1440, Image Pxls=1024 n HS=2.49, HFP=0, HBP=4.44, HB=0 n Image Lines=1024, Tot.Lines=1248, VBP=70, VS=3, PreE=PostE=3 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Keypad

Video CableVideo OUT

SiemensHICOR

Kodak MIM 200

Video CardOctopus Cable

Kpad / Host Control Octopus Adaptor Cable

Kodak 1120 camera

Fiber Cable

Page 453: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 22

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 454: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 23

Siemens HICOR/ACOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Hicor rel. VA30E Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for

8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM 200 Destinations

Hicor Setup: set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input,Direct Conn, Config.Add, Video, Qual.=Hicor/Bicor 1024 50Hz: n Board/Channel=Video60 Board 1 Channel 1, Logical Name= hicor, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n HL=32, HD=22.75, Clk=45, Tot.Pxls=1440, Image Pxls=1024 n HS=2.49, HFP=0, HBP=4.44, HB=0 n Image Lines=1024, Tot.Lines=1248, VBP=70, VS=3, PreE=PostE=3 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Keypad

Video CableVideo OUT

SiemensHICOR

Kodak MIM 200

Video CardOctopus Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

Fiber Cable

3M8700Dr yView

Kodak DryView 8700 Plus

Page 455: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 24

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=11, Film Contrast=10 n Image Dmax=2.90, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Siepoly.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 456: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 25

Siemens HICOR/ACOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Hicor rel. VA30E Requirements: MIM200 v6.1, 8100 v2.4.1 Hicor Setup: set HCD=Video_N (for 512 matrix) or Video_H (for 1024 matrix) MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,Input,Direct Conn, Config.Add, Video, Qual.=Hicor/Bicor 1024 50Hz: n Board/Channel=Video60 Board 1 Channel 1, Logical Name= hicor, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n HL=32, HD=22.75, Clk=45, Tot.Pxls=1440, Image Pxls=1024 n HS=2.49, HFP=0, HBP=4.44, HB=0 n Image Lines=1024, Tot.Lines=1248, VBP=70, VS=3, PreE=PostE=3 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Keypad

Video Cable

Kodak MIM 200

Video CardOctopus Cable

Kpad / Host Control Octopus Adaptor Cable

COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

RS4229-pole Plug

Kodak DryView8100

SiemensHICOR

Video OUT

Page 457: Siemens Setup Manuals

Siemens DSA HICOR / ACOM / BICOR / COROSCOP with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 26

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=11, Film Contrast=10 n Image Dmax=2.90, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Siepoly.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 458: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Siemens DSA Polytron TOP / Angiostar / Multistar / Neurostar with LASER IMAGERS Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer ..................................................... 2 n Kodak DryView 8700 LASER IMAGER / Plus ................................................................. 3 n Kodak DryView 8700 LASER IMAGER / Standard ......................................................... 4 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual................................................................ 5 n Kodak DryView 8500 LASER IMAGER / Plus ................................................................. 6 n Kodak DryView 8500 LASER IMAGER / Standard ......................................................... 7 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer ..................................................... 8 n Kodak DryView 8300 LASER IMAGER / Standalone ...................................................... 9 n Kodak Digital Science 969 HQ LASER IMAGER ....................................................... 10 n Kodak Digital Science 969 HQT LASER IMAGER..................................................... 11 n Kodak Digital Science 959 XL LASER IMAGER ........................................................ 12 n Kodak DryView 8100 LASER IMAGER.......................................................................... 13 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1)................................... 14

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1) ..................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) .................................................................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4)............................................................... 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4)............................................................... 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4)................................... 24

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4) ..................................................................... 26

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0.

Page 459: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Siemens Polytron TOP with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

8700 DualFiber Cable

3M 8700 DryView

3M8800Mul ti- Input Manager

Video Cable for FootswitchFootswitch

Requirements: Polytron TOP rel. VD07E, 8800 rel. 5.1, 8700 rel. 1.22 Note: for Perivision (Long Leg) special Custom Formats must be loaded into Keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8800/8700 Dual Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on EIB Menu: Parity=Enable Odd, Timeout=10

Page 460: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

Siemens Polytron TOP with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

8700 Plus

3M 8700 DryView

Video Cable for FootswitchFootswitch

Requirements: Siemens Polytron TOP rel. VD07E, 8700 Plus rel. 1.22 Note: for Perivision (Long Leg) special Custom Formats must be loaded into Keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8700 Plus Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 461: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

Siemens Polytron TOP with Kodak DryView 8700 LASER IMAGER / Standard

Video cable for Footswitch

Keypad

SPDI

Siemens 37-pinData Cable

SiemensPolytron TOP

8700 Standard

3M8700 DryView

Requirements: Siemens Polytron TOP rel. VD07E, 8700 Standard rel. 1.22 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 462: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

Siemens Polytron TOP with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

8500 DualFiber Cable

3M 8700 DryView

3M8800Mul ti- Input Manager

Video Cable for FootswitchFootswitch

Requirements: Polytron TOP rel. VD07E, 8800 rel. 5.1, 8500 rel. 1.22 Note: for Perivision (Long Leg) special Custom Formats must be loaded into Keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8800/8500 Dual Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on EIB Menu: Parity=Enable Odd, Timeout=10

Page 463: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Siemens Polytron TOP with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

8500 Plus

3M 8700 DryView

FootswitchVideo cable for Footswitch

Requirements: Polytron TOP rel. VD07E, 8500 Plus rel. 1.22 Note: for Perivision (Long Leg) special Custom Formats must be loaded into Keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8500 Plus Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 464: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

Siemens Polytron TOP with Kodak DryView 8500 LASER IMAGER / Standard

Video cable for Footswitch

Keypad

SPDI

Siemens 37-pinData Cable

SiemensPolytron TOP

8500 Standard

3M8700 DryView

Requirements: Polytron TOP rel. VD07E, 8500 Standard rel. 1.22 8500 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 465: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

Siemens Polytron TOP with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

3M 8800Mul ti- Input Manager

FootswitchVideo Cable for Footswitch

Requirements: Polytron TOP rel. VD07E, 8800 rel. 5.1, 8300 rel. 4.2 Note: for Perivision (Long Leg) special Custom Formats must be loaded into Keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON 8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n Modality Group=0

8800 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: Density=16, Contrast=10 n on EIB Menu: Parity=Enable Odd, Timeout=10

Page 466: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

Siemens Polytron TOP with Kodak DryView 8300 LASER IMAGER / Standalone

Keypad

SPDI

Siemens 37-pinData Cable

SiemensPolytron TOP 8300

Video Cable for Footswitch

Requirements: Siemens Polytron TOP rel. VD07E, 8300 rel. 4.2 8300 Setup: n on 8300 Operator Menu set:

n Density=16 n Contrast=10 n Film Layout : Format=1on 1, Mode=Portrait

n on 8300 Service Menu set: n Serial Control Interface: Protocol=Keypad n Digital Interface: Parity=Odd n Modality Group=0

Page 467: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

Siemens Polytron TOP with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

3 M H Q L a s e r I m a g e r

Video Cable for FootswitchFootswitch

Requirements: Polytron TOP rel. VD07E, M969 HQ rel. 5.1 Note: for Perivision (Long Leg) special Custom Formats must be loaded into Keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON M969 HQ Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=SIEPOLY, Dmax=2.90, Contrast=12, Density=14 n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 468: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

Siemens Polytron TOP with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQT

Keypad

SPDI

Siemens 37-pinData Cable

SiemensPolytron TOP

3 M H Q L a s e r I m a g e r

Video Cable for Footswitch

Requirements: Polytron TOP rel. VD07E, M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 M969 HQT Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMS, Contrast=15, Density=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 469: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

Siemens Polytron TOP with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

KEIB

XL Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

3 M L a se r I ma g er

Footswitch

Video Cable for Footswitch

Requirements: Siemens Polytron TOP rel. VD07E, M959 XL rel. 3.8 Setup: n on XL Control Panel set Density & Contrast depending on chemistry n on KEIB set Jumper=RS422 n on XL Input Module install LUT 322A0 M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Parity=Enable Odd, Timeout=10

Page 470: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

Siemens Polytron TOP with Kodak DryView 8100 LASER IMAGER

Copper Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

DryView 8100

Imager

RS422 9-pole Plug

FootswitchVideo Cable for Footswitch

Requirements: Polytron TOP rel. VD07E, 8100 v1.1 Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=2 n on IMAGE QUALITY-> TFT FILES Menu: TFT=SIEPOLY n on LOCAL PANEL Menu: Contrast=12, Density=2.90 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Odd

Page 471: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 14

Siemens Polytron TOP with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

DPCCopper Cable

DPI4 Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

Siemens Polytron TOP

8700 Plus

3M8700DryView

Fiber Cable

Fiber Cable

DPC-to-UKEIB Cable

9410 PACS Link

Video Cable for FootswitchFootswitch

Requirements: Polytron TOP rel. VD07E, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for

8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers.

Note: a footswitch possibility is available Polytron TOP Setup: n press Shift F4 to enter in Service Mode n into the menu Install/Config.System/Image/HC Type n set SPDI to disable Footswitch or Remote SPDI to enable Footswitch Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center

Page 472: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 15

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=10, Parity=Odd, Memory=7 n Serial Port: Protocol=SuperSet, Parity=None, Baud Rate=19200

on Device Setup, IMS KEYPADS: n Kpad=polyTOP, Hosp=sms, Serial Port=DPI4 A KPAD, Image=DPI4 A DATA n Available Printers=8700, Film Destination=Processor, TFT/ULUT=Siepoly.w87 n into Defaults: Dest=8700, Size=14x17, C=10, D=13, Dmax=2.9, Bit=8 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 473: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 16

Siemens Polytron TOP with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

Keypad

SPDI

Keypad

Siemens 37-pinData Cable

SiemensPolytron TOP

DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Video Cable for FootswitchFootswitch

Requirements: Polytron TOP rel. VD07E, 9410 v1.6, 8100 v2.4.1 Note: a footswitch possibility is available Polytron TOP Setup: n press Shift F4 to enter in Service Mode n into the menu Install/Config.System/Image/HC Type n set SPDI to disable Footswitch or Remote SPDI to enable Footswitch Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=10, Parity=Odd, Memory=7 n Serial Port: Protocol=SuperSet, Parity=None, Baud Rate=19200

on Device Setup, IMS KEYPADS: n Kpad=polyTOP, Hosp=sms, Serial Port=DPI4 A KPAD, Image=DPI4 A DATA

Page 474: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 17

n Available Printers=8100, Film Destination=Processor, TFT/ULUT=Siepoly.w87 n into Defaults: Dest=8100, Size=14x17, C=10, D=13, Dmax=2.9, Bit=8

Page 475: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 18

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 476: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 19

Siemens Polytron TOP with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Polytron TOP rel. VD07E Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: a footswitch possibility is available Footswitch adaptation pinout: Siemens Coaxial Video cable Coaxial Video side central

pin extern shield

to coax-to-RJ-connector pinout

RJ connector side viewed as you would

insert the RJ plug into your mouth, with the

click up

Very left ! ! ! ! !

Middle right ! ! ! ! !

Polytron TOP Setup: - press Shift F4 to enter in Service Mode - into the menu Install/Config.System/Image/HC Type - set SPDI to disable Footswitch or Remote SPDI to enable Footswitch MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input, Direct Conn,Config.Add, Digital,Qual=Polytron/Multistar TOP:

n Board/Channel=Digital Board 1 Channel 1, Logical Name= ptop, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear)

Siemens 37-pinData Cable

Kodak MIM 200

SiemensPolytron TOP

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 477: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 20

n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

160 Setup: no modality-specific setup needed

Page 478: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 21

Siemens Polytron TOP with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Polytron TOP rel. VD07E Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: a footswitch possibility is available Footswitch adaptation pinout: Siemens Coaxial Video cable Coaxial Video side central

pin extern shield

to coax-to-RJ-connector pinout

RJ connector side viewed as you would

insert the RJ plug into your mouth, with the

click up

Very left ! ! ! ! !

Middle right ! ! ! ! !

Polytron TOP Setup: - press Shift F4 to enter in Service Mode - into the menu Install/Config.System/Image/HC Type - set SPDI to disable Footswitch or Remote SPDI to enable Footswitch MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input, Direct Conn,Config.Add, Digital,Qual=Polytron/Multistar TOP: n Board/Channel=Digital Board 1 Channel 1, Logical Name= ptop, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue)

Siemens 37-pinData Cable

Kodak MIM 200

SiemensPolytron TOP

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Fiber Cable

Page 479: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 22

n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2

n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 480: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 23

Siemens Polytron TOP with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER Siemens Polytron TOP with Kodak MIM 200 / KELP 1120

Requirements: Polytron TOP rel. VD07E Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: a footswitch possibility is available Footswitch adaptation pinout: Siemens Coaxial Video cable Coaxial Video side central

pin extern shield

to coax-to-RJ-connector pinout

RJ connector side viewed as you would

insert the RJ plug into your mouth, with the

click up

Very left ! ! ! ! !

Middle right ! ! ! ! !

Polytron TOP Setup: - press Shift F4 to enter in Service Mode - into the menu Install/Config.System/Image/HC Type - set SPDI to disable Footswitch or Remote SPDI to enable Footswitch MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input, Direct Conn,Config.Add, Digital,Qual=Polytron/Multistar TOP: n Board/Channel=Digital Board 1 Channel 1, Logical Name= ptop, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue)

Siemens 37-pinData Cable

Kodak MIM 200

SiemensPolytron TOP

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Fiber Cable

Page 481: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 24

n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8

n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 482: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 25

Siemens Polytron TOP with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Polytron TOP rel. VD07E Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for

8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM 200 Destinations

Note: a footswitch possibility is available Footswitch adaptation pinout: Siemens Coaxial Video cable Coaxial Video side central

pin extern shield

to coax-to-RJ-connector pinout

RJ connector side viewed as you would

insert the RJ plug into your mouth, with the

click up

Very left ! ! ! ! !

Middle right ! ! ! ! !

Polytron TOP Setup: - press Shift F4 to enter in Service Mode - into the menu Install/Config.System/Image/HC Type - set SPDI to disable Footswitch or Remote SPDI to enable Footswitch MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input, Direct Conn,Config.Add, Digital,Qual=Polytron/Multistar TOP: n Board/Channel=Digital Board 1 Channel 1, Logical Name= ptop, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set:

Keypad

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

Fiber Cable

3M 8700DryView

Kodak DryView 8700 Plus

SPDI

Siemens 37-pinData Cable

RS422 37-to-50 pinDigital Adaptor Cable

SiemensPolytron TOP

Page 483: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 26

n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=11, Film Contrast=10 n Image Dmax=2.90, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Siepoly.w87, Auto Study=Off, Console=On, Annotation=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 484: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 27

Siemens Polytron TOP with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Polytron TOP rel. VD07E Requirements: MIM200 v6.1, 8100 v2.4.1 Note: a footswitch possibility is available Footswitch adaptation pinout: Siemens Coaxial Video cable Coaxial Video side central

pin extern shield

to coax-to-RJ-connector pinout

RJ connector side viewed as you would

insert the RJ plug into your mouth, with the

click up

Very left ! ! ! ! !

Middle right ! ! ! ! !

Polytron TOP Setup: - press Shift F4 to enter in Service Mode - into the menu Install/Config.System/Image/HC Type - set SPDI to disable Footswitch or Remote SPDI to enable Footswitch MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Conf.Add, Dig.,Qual.=Polytron/Multistar TOP: n Board/Channel=Digital Board 1 Channel 1, Logical Name= ptop, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=884, Lines=884, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

KeypadSiemensPolytron TOP

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

RS4229-pole Plug

Kodak DryView8100

SPDI

Siemens 37-pinData Cable

RS422 37-to-50 pinDigital Adaptor Cable

Siemens CoaxialVideoCable for Footswitch

Coaxial-to-RJ-connectorFootswitch Adaptor Cable

Page 485: Siemens Setup Manuals

Siemens DSA Polytron TOP/Angiostar/Multistar/Neurostar with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 28

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=11, Film Contrast=10 n Image Dmax=2.90, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Siepoly.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 486: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 1

Setup for Siemens Mammography Digiscan M with LASER IMAGERS (old Siemens modality, no more in production)

Siemens Digiscan M (Acquisition Console) Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGER (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGER (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 487: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 2

Siemens Digiscan M (Acquisition Console) via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Digiscan M syngo platform VC20B Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by syngo, linear-in-Density LUT into Camera Siemens syngo Setup: - on syngo into Local Service/Config/print devices declare: step 1: Host Name=PL9410, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8610, Host Sel.=PL9410, AE Title=9410, Port=1024

press button Save and then press button Verification step 3: HC Device=k8610, Type=DICOM Printer, Class=kodak8610,

DICOM Node= dv8610, Pixel Size=39x39, select Film Sheet Formats Portrait: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=5024x6200, select Film Sheet Formats Landscape: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=6200x5024, Medium Type=Blue Film, Film Destination=Processor, Color Appearance=monochrome, Background=black, Transformation=no magnification, press button Save

- on syngo into Local Service/Config/DICOM LUT files syngo configured with DXMG Image=CR, Max Density=3.50 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case setup used Dmax=350, C=6, Modality Group=1

9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5

Siemens Mammomat 3000 NovaDigiscan M CR-readersyngo platformOperator Console

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 488: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 3

n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=6 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=90, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Linear OD, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 489: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 4

Siemens Digiscan M (Acquisition Console) via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Digiscan M syngo platform VC20B Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by syngo, linear-in-Density LUT into Camera Siemens syngo Setup: - on syngo into Local Service/Config/print devices declare: step 1: Host Name=MIM, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8610, Host Sel.=MIM, AE Title=8610, Port=5040

press button Save and then press button Verification step 3: HC Device=k8610, Type=DICOM Printer, Class=kodak8610,

DICOM Node= dv8610, Pixel Size=39x39, select Film Sheet Formats Portrait: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=5024x6200, select Film Sheet Formats Landscape: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=6200x5024, Medium Type=Blue Film, Film Destination=Processor, Color Appearance=monochrome, Background=black, Transformation=no magnification, press button Save

- on syngo into Local Service/Config/DICOM LUT files syngo configured with DXMG Image=CR, Max Density=3.50 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case setup used Dmax=350, C=1, Modality Group=1

MIM200 Setup: n on Configure, Network:

Siemens Mammomat 3000 NovaDigiscan M CR-readersyngo platformOperator Console

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 490: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 5

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=6 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=digm n Print Priority=Normal (Always=N), Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

Page 491: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 6

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 492: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 7

Siemens Digiscan M (Acquisition Console) via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Digiscan M syngo platform VC20B Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Siemens syngo Setup: - on syngo into Local Service/Config/print devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8900, Host Sel.=dv8900, AE Title=8900, Port=5040

press button Save and then press button Verification step 3: HC Device=8900, Type=DICOM Printer,

Class= kodak8900HiRes_smallB (or kodak8610), DICOM Node= k8900, Pixel Size=39x39, select Film Sheet Formats Portrait: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=5056x6368, select Film Sheet Formats Landscape: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=6368x5056, Medium Type=Blue Film, Film Destination=Processor, Color Appearance=monochrome, Background=black, Transformation=no magnification, press button Save

- on syngo into Local Service/Config/DICOM LUT files syngo configured with DXMG Image=CR, Max Density=3.50 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case setup used Dmax=350, C=1, TFT=Wrkstn2a

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

DICOM Network

Kodak DryView 8900

Siemens Mammomat 3000 NovaDigiscan M CR-readersyngo platformOperator Console

Page 493: Siemens Setup Manuals

Siemens Mammography Digiscan M (Acquisition Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 8

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Wrkstn2a.w87 (Always=N), Contrast=1 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 494: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 1

Setup for Siemens Mammography MagicView 1000 with LASER IMAGERS (old Siemens modality, no more in production) Siemens MagicView 1000 (Review Console) Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGER (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGER (see also 8600) .................................................................................................................. 5

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 8

Page 495: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 2

Siemens MagicView 1000 (Review Console) via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: MagicView 1000 rel.VB33 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by MagicView, linear-in-Density LUT into Camera MagicView Setup (using 8600 Config.File): - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8610 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8600_Dicom, - DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter number of printer to be installed eg 1=kodakd Kodak_DryView_8600_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView To verify True Size on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Segment Type=anatomical, Scale=ON To eliminate white bands on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Background R=0, G=0, B=0 MagicView Setup to print images with Dmax=350:

Siemens Mammomat 3000 NovaMagicView 1000 platformReview Console

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Page 496: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 3

- into Service Login (at Unix level), edit density.dat file and set 350 Dmax value for digital-mammo images ie

cd /home/cs_root/data/lut vi density.dat change the following 6 lines as follows:

0 DX 350 0 CR 350 0 MG 350 0 CT 350 (this line needed when Ref.Test Patterns eg SMPTE are used) 0 OT 350 0 DEFAULT 350

reboot MagicView MagicView Setup to print with Image Data lutted by MV, not lutted by 8610 (setup: Gamma=Lin.in Density, C=6, Modality Group=1): - into Service Login (at Unix level),

edit LUT^CR.def file and modify it with following exp / density value pairs ie cd /home/cs_root/data/lut vi LUT^CR.def change the lines as follows: 0 20 25 31 51 42 76 56 102 73 127 93 153 115 178 143 204 182 229 230 255 300 copy LUT^CR.def file into the LUT^CT.def, LUT^MG.def and LUT^DX.def files (ie LUT^CR.def is the file with LUT applied by MV to image data and is copied into LUT^CT.def, LUT^MG.def and LUT^DX.def to be sure to have same LUT applied by MV to image data no matter which Modality-tag have the image data) ie cd /home/cs_root/data/lut cp LUT^CR.def LUT^CT.def (needed when Ref. Test Patterns eg SMPTE used) cp LUT^CR.def LUT^MG.def cp LUT^CR.def LUT^DX.def reboot MagicView

Page 497: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 4

9410 Setup: n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr= accordingly n SCP=8610, Copies=1, Contrast Table=6 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma=Linear OD, Image Size=Scale To Fit, Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 498: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 5

Siemens MagicView 1000 (Review Console) via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: MagicView 1000 rel.VB33 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by MagicView, linear-in-Density LUT into Camera MagicView Setup (using 8600 Config.File): - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8610 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8600_Dicom, - DICOM services=PRINT_SCP, aet=8610, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter number of printer to be installed eg 1=kodakd Kodak_DryView_8600_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView To verify True Size on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Segment Type=anatomical, Scale=ON To eliminate white bands on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Background R=0, G=0, B=0 MagicView Setup to print images with Dmax=350:

Siemens Mammomat 3000 NovaMagicView 1000 platformReview Console

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 499: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 6

- into Service Login (at Unix level), edit density.dat file and set 350 Dmax value for digital-mammo images ie

cd /home/cs_root/data/lut vi density.dat change the following 6 lines as follows:

1 DX 350 1 CR 350 1 MG 350 1 CT 350 (this line needed when Ref.Test Patterns eg SMPTE are used) 0 OT 350 0 DEFAULT 350

reboot MagicView MagicView Setup to print with Image Data lutted by MV, not lutted by 8610 (setup: Gamma=Lin.in Density, C=6, Modality Group=1): - into Service Login (at Unix level),

edit LUT^CR.def file and modify it with following exp / density value pairs ie cd /home/cs_root/data/lut vi LUT^CR.def change the lines as follows: 1 20 26 31 52 42 77 56 103 73 128 93 154 115 179 143 205 182 230 230 255 300 copy LUT^CR.def file into the LUT^CT.def, LUT^MG.def and LUT^DX.def files (ie LUT^CR.def is the file with LUT applied by MV to image data and is copied into LUT^CT.def, LUT^MG.def and LUT^DX.def to be sure to have same LUT applied by MV to image data no matter which Modality-tag have the image data) ie cd /home/cs_root/data/lut cp LUT^CR.def LUT^CT.def (needed when Ref. Test Patterns eg SMPTE used) cp LUT^CR.def LUT^MG.def cp LUT^CR.def LUT^DX.def reboot MagicView

MIM200 Setup:

Page 500: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 7

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set:

n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600),Header/Line,Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=6 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=nova n Print Priority=Normal (Always=N), Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P

Page 501: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 8

n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 502: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 9

Siemens MagicView 1000 (Review Console) via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: MagicView 1000 rel.VB33 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) MagicView Setup (using 3M M969 HQ Config.file, easier configuration): - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8900 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_M969_HQ_Dicom, - DICOM services=PRINT_SCP, aet=8900, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_M969_HQ_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView - note: into 8900 Config., DICOM SCP, SCP Services, set Smoothing=0 (Always=Y) MagicView Setup (creating 8900 by modifying files, only if True Size needed): - into Service Login (at Unix level) in /home/cs_root/data/camera directory

dbp_format.dat and dbp_camera_types.dat files needs to be edited by adding the DV8900 matrixes ie cd /home/cs_root/data/camera vi dbp_format.dat add the following lines:

Kodak_DryView_8900_Hires_Dicom 14x17 350.75x427.03 8976x10928 650 Kodak_DryView_8900_Hires_Dicom 14x14 350.75x350.75 8976x8976 650 Kodak_DryView_8900_Hires_Dicom 11x14 274.63x350.75 7028x8976 650 Kodak_DryView_8900_Hires_Dicom 10x12 248.84x299.17 6368x7656 650 Kodak_DryView_8900_Hires_Dicom 8x10 197.57x248.84 5056x6368 650

DICOM Network

Kodak DryView 8900

Siemens Mammomat 3000 NovaMagicView 1000 platformReview Console

Page 503: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 10

cd /home/cs_root/data/camera vi dbp_camera_types.dat add the following line:

Kodak_DryView_8900_ Hires_Dicom - reboot MagicView - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8900 Dicom Printer, - modality type=DICOM_PRINTER, - camera type=Kodak_DryView_8900_ Hires_Dicom, - DICOM services=PRINT_SCP, aet=8900, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter nbr of printer to install eg 1=kodakd Kodak_DryView_8900_ Hires_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView - at this point only a default-Layout ie printing format is available for 8900 - other Layouts ie other printing formats could be manually genarated

by using the Layout-Editor which is present inside MagicView application - otherwise other Layouts ie other printing formats could be automatically

generated deriving them from the Layouts of an already existing camera - to automatic generate other Layouts ie other printing formats

from main menu do: hc_install/modify/copy layouts input=Kodak_KELP_2180_Dicom output=Kodak_DryView_8900_ Hires_Dicom

- reboot MagicView To verify True Size on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Segment Type=anatomical, Scale=ON To eliminate white bands on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Background R=0, G=0, B=0 MagicView Setup to print images with Dmax=350: - into Service Login (at Unix level),

edit density.dat file and set 350 Dmax value for digital-mammo images ie

cd /home/cs_root/data/lut vi density.dat change the following 6 lines as follows:

Page 504: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 11

2 DX 350 2 CR 350 2 MG 350 2 CT 350 (this line needed when Ref.Test Patterns eg SMPTE are used) 0 OT 350 0 DEFAULT 350

reboot MagicView MagicView Setup to print with Image Data lutted by MV, not lutted by 8900 (setup: C=1, TFT=Wrkstn2a): - into Service Login (at Unix level),

edit LUT^CR.def file and modify it with following exp / density value pairs ie cd /home/cs_root/data/lut vi LUT^CR.def change the lines as follows: 2 20 27 31 53 42 78 56 104 73 129 93 155 115 180 143 206 182 231 230 255 300 copy LUT^CR.def file into LUT^CT.def, LUT^MG.def and LUT^DX.def files (ie LUT^CR.def is the file with LUT applied by MV to image data and is copied into LUT^CT.def, LUT^MG.def and LUT^DX.def to be sure to have same LUT applied by MV to image data no matter which Modality-tag have the image data) ie cd /home/cs_root/data/lut cp LUT^CR.def LUT^CT.def (needed when Ref. Test Patterns eg SMPTE used) cp LUT^CR.def LUT^MG.def cp LUT^CR.def LUT^DX.def reboot MagicView

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications:

Page 505: Siemens Setup Manuals

Siemens Mammography MagicView 1000 (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ´04 12

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Wrkstn2a.w87 (Always=N), Contrast=1 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 506: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for Siemens Mammography Novation DR (Acquisition Console) DROC platform with LASER IMAGERS Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 507: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Novation DR (Acquisition Console) DROC platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Novation DROC platform MAMMODROC v3_0_0_15 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by Siemens, linear-in-Density LUT into Camera Siemens DROC Setup: n Log as Service n into Service Tools under Service Shortcut menu select Add New Output Device n here Browse Directory ./installable/vdevices/output/laser_cameras n here Install the Kodak DV8610 laser imager connected via Kodak PL MIM200 n here select Return to updated Software Configuration Page n here click on Service Tools n into Service Tools under Service Shortcut menu select Configure Output Devices n here Browse Directory ./ installed/vdevices/output/laser_cameras n here Edit Kodak 8610 connected via MIM200 (aliased to Kodak DryView 8610) n ALIAS NAME=Kodak 8610, n EXPLICIT_INSTALL=TRUE, SERVER ACTIVE=FALSE n click Update n click on Service Tools n into Service Tools under Service Shortcut menu select Configure Output Devices n here Browse Directory ./ installed/vdevices/output/laser_cameras n here Edit the Kodak DV8610 connected via MIM200 (aliased to Kodak 8610) n here Edit configuration file /linx_mp/resources/installed/raw/

vdevdryview8610_001/dryview8610.cfg n factory object name=supplied by system, spooler name=DicomPrintSpooler, n priority=normal, max retries=20, device type=DRYVIEW, n device name (ie Aetitle)=9410,

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Siemens mammography Mammomat Novation DRAcquisition WorkStationDROC platform

Kodak 9410 PACS Link

Page 508: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

n device address (ie IPaddr : Port)= eg 150.224.150.22:1024 n request annotation SOP class=false, request print job SOP class=false, n print job poll period=15, print job timeout=300, printer poll period=15, n association timeout=0, collate=false, custom lut file= n photometric interpr.=automatic, copies=1, medium type=BLUE FILM, n film destination=PROCESSOR, film session label=DROC film, n memory allocation=0, Print priority=MED, n available image display formats=PORTRAIT\1,1 n image display format=PORTRAIT\1,1, annotation display format id=6 n number of annotation boxes=6, annotation boxes per text line=3 n max annotation box text string size=64, annotation string= n max text line size=189, number of image text lines=5, image text position=left n image text overlap=overwrite, image text reorient=reorient_0 n film size id=8INX10IN, n film magnification type=REPLICATE, film smoothing type=NONE, n border density=BLACK, empty image density=BLACK, full pixel range=true, n min density=20, max density=350, configuration info= LUT=0,5, trim=NO, n polarity=NORMAL, available image mag.types=REPLICATE BILINEAR CUBIC n image mag.type= REPLICATE, image smoothing type= NONE, n true size capable=true, pixel size=70, pad=false, image text line 1 till 5= n annotation position=1 till 6, text string=<off>, n width=2781, height=3430 n click Update, click Return to Updated Installation page, click on Service Tools n (note if any parameter changed, click on Update and reboot DROC to be effective) n Log as Application n into Edit/Outputs/New input the output name Kodak DryView 8610, click OK n select Kodak DryView 8610 and click Edit n select laser_cameras tab, select Kodak 8610, click Add, click Accept, click OK n to print select Admin/Spool Management/Patient and select Outputs=Kodak 8610 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=5 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=90, Transfer Rate=2 MHz

Page 509: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Linear OD, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 510: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

Novation DR (Acquisition Console) DROC platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Novation DROC platform MAMMODROC v3_0_0_15 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by Siemens, linear-in-Density LUT into Camera Siemens DROC Setup: n Log as Service n into Service Tools under Service Shortcut menu select Add New Output Device n here Browse Directory ./installable/vdevices/output/laser_cameras n here Install the Kodak DV8610 laser imager connected via Kodak PL MIM200 n here select Return to updated Software Configuration Page n here click on Service Tools n into Service Tools under Service Shortcut menu select Configure Output Devices n here Browse Directory ./ installed/vdevices/output/laser_cameras n here Edit Kodak 8610 connected via MIM200 (aliased to Kodak DryView 8610) n ALIAS NAME=Kodak 8610, n EXPLICIT_INSTALL=TRUE, SERVER ACTIVE=FALSE n click Update n click on Service Tools n into Service Tools under Service Shortcut menu select Configure Output Devices n here Browse Directory ./ installed/vdevices/output/laser_cameras n here Edit the Kodak DV8610 connected via MIM200 (aliased to Kodak 8610) n here Edit configuration file /linx_mp/resources/installed/raw/

vdevdryview8610_001/dryview8610.cfg n factory object name=supplied by system, spooler name=DicomPrintSpooler, n priority=normal, max retries=20, device type=DRYVIEW, n device name (ie Aetitle)=8610,

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Siemens mammography Mammomat Novation DRAcquisition WorkStationDROC platform

Page 511: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

n device address (ie IPaddr : Port)= eg 150.224.150.22:5040 n request annotation SOP class=false, request print job SOP class=false, n print job poll period=15, print job timeout=300, printer poll period=15, n association timeout=0, collate=false, custom lut file= n photometric interpr.=automatic, copies=1, medium type=BLUE FILM, n film destination=PROCESSOR, film session label=DROC film, n memory allocation=0, Print priority=MED, n available image display formats=PORTRAIT\1,1 n image display format=PORTRAIT\1,1, annotation display format id=6 n number of annotation boxes=6, annotation boxes per text line=3 n max annotation box text string size=64, annotation string= n max text line size=189, number of image text lines=5, image text position=left n image text overlap=overwrite, image text reorient=reorient_0 n film size id=8INX10IN, n film magnification type=REPLICATE, film smoothing type=NONE, n border density=BLACK, empty image density=BLACK, full pixel range=true, n min density=20, max density=350, configuration info= LUT=0,5, trim=NO, n polarity=NORMAL, available image mag.types=REPLICATE BILINEAR CUBIC n image mag.type= REPLICATE, image smoothing type= NONE, n true size capable=true, pixel size=70, pad=false, image text line 1 till 5= n annotation position=1 till 6, text string=<off>, n width=2781, height=3430 n click Update, click Return to Updated Installation page, click on Service Tools n (note if any parameter changed, click on Update and reboot DROC to be effective) n Log as Application n into Edit/Outputs/New input the output name Kodak DryView 8610, click OK n select Kodak DryView 8610 and click Edit n select laser_cameras tab, select Kodak 8610, click Add, click Accept, click OK n to print select Admin/Spool Management/Patient and select Outputs=Kodak 8610 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Page 512: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n Contrast (dry)=5 (Always=N) n Modality Group=1 (which corresponds to TFT/ULUT=upmsv3kp.w8u) n Conv.Group=1, Gamma Table=Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=droc n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 513: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

Novation DR (Acquisition Console) DROC platform via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Novation DROC platform MAMMODROC v3_0_0_15 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Image Data lutted by Siemens, linear-in-Density LUT into Camera Siemens DROC Setup: n Log as Service n into Service Tools under Service Shortcut menu select Add New Output Device n here Browse Directory ./installable/vdevices/output/laser_cameras n here Install the Kodak DV8610 laser imager connected via Kodak PL MIM200 n here select Return to updated Software Configuration Page n here click on Service Tools n into Servic e Tools under Service Shortcut menu select Configure Output Devices n here Browse Directory ./ installed/vdevices/output/laser_cameras n here Edit Kodak 8610 connected via MIM200 (aliased to Kodak DryView 8610) n ALIAS NAME=Kodak 8900, n EXPLICIT_INSTALL=TRUE, SERVER ACTIVE=FALSE n click Update n click on Service Tools n into Service Tools under Service Shortcut menu select Configure Output Devices n here Browse Directory ./ installed/vdevices/output/laser_cameras n here Edit the Kodak DV8610 connected via MIM200 (aliased to Kodak 8900) n here Edit configuration file /linx_mp/resources/installed/raw/

vdevdryview8610_001/dryview8610.cfg n factory object name=supplied by system, spooler name=DicomPrintSpooler, n priority=normal, max retries=20, device type=DRYVIEW, n device name (ie Aetitle)=8900, n device address (ie IPaddr : Port)= eg 150.224.150.22:5040 n request annotation SOP class=false, request print job SOP class=false, n print job poll period=15, print job timeout=300, printer poll period=15, n association timeout=0, collate=false, custom lut file=

DICOM Network

Kodak DryView 8900

Siemens mammography Mammomat Novation DRAcquisition WorkStationDROC platform

Page 514: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

n photometric interpr.=automatic, copies=1, medium type=BLUE FILM, n film destination=PROCESSOR, film session label=DROC film, n memory allocation=0, Print priority=MED, n available image display formats=PORTRAIT\1,1 n image display format=PORTRAIT\1,1, annotation display format id=6 n number of annotation boxes=6, annotation boxes per text line=3 n max annotation box text string size=64, annotation string= n max text line size=189, number of image text lines=5, image text position=left n image text overlap=overwrite, image text reorient=reorient_0 n film size id=automatic, n film magnification type=REPLICATE, film smoothing type=NONE, n border density=BLACK, empty image density=BLACK, full pixel range=true, n min density=20, max density=350, trim=NO, n configuration info=LUT=Wrkstn2a.w87,1 n polarity=NORMAL, available image mag.types=REPLICATE BILINEAR CUBIC n image mag.type= REPLICATE, image smoothing type= NONE, n true size capable=true, pixel size=70, pad=false, image text line 1 till 5= n annotation position=1 till 6, text string=<off>, n width=3337, height=4114 n click Update, click Return to Updated Installation page, click on Service Tools n (note if any parameter changed, click on Update and reboot DROC to be effective) n Log as Application n into Edit/Outputs/New input the output name Kodak DryView 8900, click OK n select Kodak DryView 8900 and click Edit n select laser_cameras tab, select Kodak 8900, click Add, click Accept, click OK n to print select Admin/Spool Management/Patient and select Outputs=Kodak 8900 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On

Page 515: Siemens Setup Manuals

Siemens Mammography Novation DR (Acq.Console) DROC platform with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30 n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=Wrkstn2a.w87 (Always=N), Contrast=1 (Always=N) n Smoothing Type=15 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 516: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 1

Setup for Siemens Mammography Novation DR (Acquisition Console) WH-AWS syngo platform with LASER IMAGERS Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGER (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGER (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 517: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 2

Novation DR Women’s Health Acquisition WorkStation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: WH-AWS VA10A Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Siemens syngo Setup: - on syngo into Local Service/Config/print devices declare: step 1: Host Name=PL9410, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8610, Host Sel.=PL9410, AE Title=9410, Port=1024

press button Save and then press button Verification step 3: HC Device=k8610, Type=DICOM Printer, Class=kodak8610,

DICOM Node= dv8610, Pixel Size=39x39, select Film Sheet Formats Portrait: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=5024x6200, select Film Sheet Formats Landscape: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=6200x5024, Medium Type=Blue Film, Film Destination=Processor, Color Appearance=monochrome, Background=black, Transformation=no magnification, press button Save

- on syngo into Local Service/Config/DICOM LUT files syngo configured with DXMG Image=CR, Max Density=3.50 then Image Data lutted by syngo, linear-in-Density LUT into Camera

9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=6

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Siemens mammographyMammomat Novation DR Women’s HealthAcquisition WorkStationsyngo platform

Page 518: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 3

n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=90, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Linear OD, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 519: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 4

Novation DR Women’s Health Acquisition WorkStation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: WH-AWS VA10A Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Siemens syngo Setup: - on syngo into Local Service/Config/print devices declare: step 1: Host Name=MIM, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8610, Host Sel.=MIM, AE Title=8610, Port=5040

press button Save and then press button Verification step 3: HC Device=k8610, Type=DICOM Printer, Class=kodak8610,

DICOM Node= dv8610, Pixel Size=39x39, select Film Sheet Formats Portrait: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=5024x6200, select Film Sheet Formats Landscape: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=6200x5024, Medium Type=Blue Film, Film Destination=Processor, Color Appearance=monochrome, Background=black, Transformation=no magnification, press button Save

- on syngo into Local Service/Config/DICOM LUT files syngo configured with DXMG Image=CR, Max Density=3.50 then Image Data lutted by syngo, linear-in-Density LUT into Camera

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Siemens mammographyMammomat Novation DR Women’s HealthAcquisition WorkStationsyngo platform

Page 520: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 5

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=6 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=ws n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 521: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 6

Novation DR Women’s Health Acquisition WorkStation via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: WH-AWS VA10A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Siemens syngo Setup: - on syngo into Local Service/Config/print devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8900, Host Sel.=dv8900, AE Title=8900, Port=5040

press button Save and then press button Verification step 3: HC Device=8900, Type=DICOM Printer,

Class= kodak8900HiRes_smallB (or kodak8610), DICOM Node= k8900, Pixel Size=39x39, select Film Sheet Formats Portrait: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=5056x6368, select Film Sheet Formats Landscape: Inch8x10, it appears Film Sheet Format=Inch8x10, Nbr.Pixel (cols,rows)=6368x5056, Medium Type=Blue Film, Film Destination=Processor, Color Appearance=monochrome, Background=black, Transformation=no magnification, press button Save

- on syngo into Local Service/Config/DICOM LUT files syngo configured with DXMG Image=CR, Max Density=3.50 then Image Data lutted by syngo, linear-in-Density LUT into Camera

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination:

DICOM Network

Kodak DryView 8900

Siemens mammographyMammomat Novation DR Women’s HealthAcquisition WorkStationsyngo platform

Page 522: Siemens Setup Manuals

Siemens Mammography Novation DR Women’s Health Acquisition WorkStation with LASER IMAGER Products

Author: [email protected], Edition: November ´04 7

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=Wrkstn2a.w87 (Always=N), Contrast=1 (Always=N) n Smoothing Type=5 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 523: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for Siemens Mammography Opdima with LASER IMAGERS (old Siemens modality, no more in production) Siemens Opdima Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 524: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Siemens Opdima via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Opdima v3.1 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data not lutted by Opdima, lutted by Camera Siemens Opdima Setup: - under Service/Advanced Service/Network Setup/DICOM Nodes/Add: - Node Name=Kodak, AEtitle=9410, Host Name=9410MFG01, - IPaddr=accordingly, Port=1024, Printer=selected 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831

Siemens Opdima workstation

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 525: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 526: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

Siemens Opdima via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Opdima v3.1 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data not lutted by Opdima, lutted by Camera Siemens Opdima Setup: - under Service/Advanced Service/Network Setup/DICOM Nodes/Add: - Node Name=Kodak, AEtitle=8610, Host Name=MIM, - IPaddr=accordingly, Port=5040, Printer=selected MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On

Siemens Opdima workstation

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 527: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n Contrast (dry)=3 (Always=N) n Modality Group=6 (which corresponds to TFT/ULUT=gsdfaa0p.w8u) n Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=ws n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 528: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Siemens Opdima via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Opdima v3.1 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Image Data not lutted by Opdima, lutted by Camera Siemens Opdima Setup: - under Service/Advanced Service/Network Setup/DICOM Nodes/Add: - Node Name=Kodak, AEtitle=8900, Host Name=DV8900, - IPaddr=accordingly, Port=5040, Printer=selected 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On,

Siemens Opdima workstation

DICOM Network

Kodak DryView 8900

Page 529: Siemens Setup Manuals

Siemens Mammography Opdima with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=15 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 530: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for Siemens Mammography Mammo Report Plus with LASER IMAGERS Siemens Mammo Report Plus (Review Console) Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 531: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Siemens Mammo Report Plus (Review Console) via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Mammo Report Plus VA20 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: in sw VA20 Image Data lutted by Siemens, linear-in-Density LUT into Camera Siemens Mammo Report Plus Setup: - login as Service - into Administration / DICOM / Setup / DICOM Setup set: - Entity Type: Printer=On, AEtitle=9410, IPaddr=accordingly, Port=1024 - into Administration / DICOM / Printer set: - Printer Name=Kodak 8610, Dmax=350 - Printer Setup: Config.Info=LUT=0,5 - Portrait matrix (Columns x Rows)=5024 x 6200 - Landscape matrix (Columns x Rows)=6200 x 5024 - Graylevel 16(12)=On (Off if 8600), 8=Off (On if 8600) - Medium=Blue Film, Medium Size=8INX10IN 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr= accordingly n SCP=8610, Copies=1, Contrast Table=5 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=No

Siemens Mammomat 3000 NovaMammo Report PlusReview Console

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 532: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma Table= Xmittance, Image Size=Scale To Fit n Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 533: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

Siemens Mammo Report Plus (Review Console) via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Mammo Report Plus VA20 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: in sw VA20 Image Data lutted by Siemens, linear-in-Density LUT into Camera Siemens Mammo Report Plus Setup: - login as Service - into Administration / DICOM / Setup / DICOM Setup set: - Entity Type: Printer=On, AEtitle=8610, IPaddr=accordingly, Port=5040 - into Administration / DICOM / Printer set: - Printer Name=Kodak 8610, Dmax=350 - Printer Setup: Config.Info=LUT=0,5 - Portrait matrix (Columns x Rows)=5024 x 6200 - Landscape matrix (Columns x Rows)=6200 x 5024 - Graylevel 16(12)=On (Off if 8600), 8=Off (On if 8600) - Medium=Blue Film, Medium Size=8INX10IN MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue

Siemens Mammomat 3000 NovaMammo Report PlusReview Console

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 534: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y), Contrast (dry)=5 (Always=N), n Modality Group=1 (which corresponds to TFT/ULUT=upmsv3kp.w8u), n Conv.Group=1, Gamma Table= Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=rplus n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Xmittance, Image Size=Scale To Fit, Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 535: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Siemens Mammo Report Plus (Review Console) via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Mammo Report Plus VA20 Requirements: 8900 rev.E ie release 2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: in sw VA20 Image Data lutted by Siemens, linear-in-Density LUT into Camera Siemens Mammo Report Plus Setup: - login as Service - into Administration / DICOM / Setup / DICOM Setup set: - Entity Type: Printer=On, AEtitle=8900, IPaddr=accordingly, Port=5040 - into Administration / DICOM / Printer set: - Printer Name=Kodak 8900, Dmax=350 - Printer Setup: Config.Info= LUT=Wrkstn2a.w87,1 - Printer Setup: Portrait matrix (Columns x Rows)=5056 x 6368 (for 8x10) - Printer Setup: Landscape matrix (Columns x Rows)=6368 x 5056 (for 8x10) - Printer Setup: Medium=Blue Film, Medium Size=8INx10IN - Printer Setup: Graylevel 16(12)=On, 8=Off - Printer Setup: Portrait matrix (Columns x Rows)=6368 x 7656 (for 10x12) - Printer Setup: Landscape matrix (Columns x Rows)=7656 x 6368 (for 10x12) - Printer Setup: Medium=Blue Film, Medium Size=10INx12IN 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any

DICOM Network

Kodak DryView 8900

Siemens Mammomat 3000 NovaMammo Report PlusReview Console

Page 536: Siemens Setup Manuals

Siemens Mammography Mammo Report Plus (Review Console) with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=Wrkstn2a.w87 (Always=N), Contrast=1 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 537: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens MR Harmony / Symphony / Sonata / Rhapsody / Concerto / Trio / Allegra / Avanto / Espree with LASER IMAGERS

Important note: from mid 2000 MR models Harmony/Symphony/Sonata switched to the Numaris 4 syngo-based platform. Here you find Harmony/Symphony/Sonata syngo-based setup

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER..................................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER .................................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1)............. 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1)................................................................................ 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1)................................................................................ 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ............................................................................. 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .......................................................................... 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .......................................................................... 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)............................................................................ 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4,5) ......... 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5)....................................................................... 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5)....................................................................... 22 n Kodak DryView 8900 LASER IMAGER..................................................................................... 24 n Kodak DryView 8150 LASER IMAGER..................................................................................... 26 n Kodak Color Medical Imager 1000............................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER

Page 538: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

MR based on syngo via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8300

DICOM Network

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=10, Modality Group=0

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 10 or b) 1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=a) 0 or b) 4

Page 539: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

MR based on syngo via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

DICOM Network

Kodak 190 camera

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 190 rel. 1.7.29 Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use use Dmax=300, Curve Shape=3.0, Film Contrast=0 (use this config. in case also a Virtuoso workstation is printing on same camera)

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=a) 3.0 or b) 0.0, Contrast=0 n Contrast Pivot Density=1.2, IPAddress=accordingly n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 540: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

MR based on syngo via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and if HQ by installing HQ into syngo DICOM Camera Config.File.

Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber

Page 541: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 9 or b) 2 n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 542: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

MR based on syngo via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 9410 v1.6, 8100 v2.4.1 Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Page 543: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 9 or b) 2 n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 544: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

MR based on syngo via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=10, Modality Group=0

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

Page 545: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 10 or b) 1 n TFT/ULUT=a) u1_109b.w8u or b) wrkstn2a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 546: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use use Dmax=300, Curve Shape=434 (i.e., 3.0), Film Contrast=0

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160

Page 547: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 548: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, 2180 v2.17H Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180

Page 549: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 550: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k1120, Host Sel.=k1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=k1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=k1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly

Page 551: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 552: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use use Dmax=300, C=9, TFT=PMSB

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

Page 553: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +9 or b) +2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 554: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and if HQ by installing HQ into syngo DICOM Camera Config.File.

Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network:

Page 555: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 9 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 556: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

Page 557: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 9 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 558: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

MR based on syngo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/ConcertoNumaris 4 syngo platform

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=10, Modality Group=0

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

Page 559: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Admin, Update SCU Connection Database, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) u1_109b.w8u or b) wrkstn2a.w8u (Always=Y) n Contrast (dry)=a) 10 or b) 1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 560: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

MR based on syngo via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) into Local Service/Config/DICOM LUT files set MR Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSV3K

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

DICOM Network

Kodak DryView 8900

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/Concerto- Trio/Allegra/AvantoNumaris 4 syngo platform

Page 561: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 9 or b) 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mr

Page 562: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

MR based on syngo via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: MREase VA21B and VA25D, for the model Avanto VB11A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) in Local Service/Config/DICOM LUT files set MR Image=linear,MaxDens=3.0

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB

b) into Local Service/Config/DICOM LUT files set MR Image=MR1, MaxDens=3.00 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/Concerto- Trio/Allegra/AvantoNumaris 4 syngo platform

DICOM Network

Kodak DryView 8150

Page 563: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast=a) 9 or b) 1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 564: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

MR based on syngo via DICOM with Kodak Color Medical Imager 1000

Requirements: MREase VA21B and VA25D and VB11A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: syngo could be configured with a) LUT=linear or b) LUT=MR1 a) in Local Service/Config/DICOM LUT files set MR Image=linear

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=9, TFT=PMSB

b) into Local Service/Config/DICOM LUT files set MR Image=MR1 if LUT=MR1 then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=7, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set MR Image=a) linear or b) MR1, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000

DICOM Network

Kodak CMI 1000

Siemens MR- Harmony/Symphony/Sonata- Rhapsody/Concerto- Trio/Allegra/Avanto/EspreeNumaris 4 syngo platform

Page 565: Siemens Setup Manuals

Siemens MR platform Numaris 4, based on syngo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 9 or b) 7 (Always=Y) n TFT Set (From list)=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 566: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens MR Jazz with LASER IMAGERS Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer.................................................. 3 n Kodak DryView 8700 LASER IMAGER / Plus............................................................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ....................................................... 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer.................................................. 6 n Kodak DryView 8500 LASER IMAGER / Plus............................................................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ....................................................... 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer.................................................. 9 n Kodak DryView 8300 LASER IMAGER / Standalone.................................................... 10 n Kodak Digital Science 969 HQ LASER IMAGER...................................................... 11 n Kodak Digital Science 969 HQT LASER IMAGER ................................................... 12 n Kodak Digital Science 959 XL LASER IMAGER ...................................................... 13 n Kodak DryView 8100 LASER IMAGER......................................................................... 14 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (not ok, image transfer incompatibility)

n Kodak PACS LINK 9410 ACQUISITION SYSTEM / Kodak DryView 8100 LASER IMAGER (not ok, image transfer incompatibility)

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 15

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 17

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 19

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) . 21

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4).................................................................... 23

Page 567: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 25 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 26 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 27 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 29 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 31 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 33 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 35 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 37 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 39 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 41 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 43 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 45 n Kodak DryView 8900 LASER IMAGER......................................................................... 47 n Kodak DryView 8150 LASER IMAGER......................................................................... 49 n Kodak Color Medical Imager 1000 ................................................................................. 51

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 568: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens MR Magnetom Jazz with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-In

putManag

er

Requirements: Magnetom Jazz rel. VA12A, 8800 rel. 5.1, 8700 rel. 1.22 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8800/8700 Dual Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 569: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens MR Magnetom Jazz with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

8700 Plus

3M 8700 DryView

Requirements: Siemens Magnetom Jazz rel. VA12A, 8700 Plus rel. 1.22 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu:

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 570: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Siemens MR Magnetom Jazz with Kodak DryView 8700 LASER IMAGER / Standard

Keypad

Digital Board Data output

Data Cable 37-pin

Siemens Magnetom Jazz MR

8700 Standard

3M 8700 DryView

Requirements: Siemens Magnetom Jazz rel. VA12A, 8700 Standard rel. 1.22 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 571: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens MR Magnetom Jazz with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

8500 DualFiber Cable

3M 8700 DryView

3M8800Multi-In

putManag

er

Requirements: Magnetom Jazz rel. VA12A, 8800 rel. 5.1, 8500 rel. 1.22 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8800/8500 Dual Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 572: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Siemens MR Magnetom Jazz with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

8500 Plus

3M 8700 DryView

Requirements: Magnetom Jazz rel. VA12A, 8500 Plus rel. 1.22 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 573: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens MR Magnetom Jazz with Kodak DryView 8500 LASER IMAGER / Standard

Keypad

Digital Board Data output

Data Cable 37-pin

Siemens Magnetom Jazz MR

8500 Standard

3M 8700 DryView

Requirements: Magnetom Jazz rel. VA12A, 8500 Standard rel. 1.22 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad 8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Left n on COMM Menu: 8700 Keypad Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 574: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Siemens MR Magnetom Jazz with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer

DryView 8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

3M8800Multi-InputManager

Requirements: Magnetom Jazz rel. VA12A, 8800 rel. 5.1, 8300 rel. 4.2

Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad

Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center

8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial: Baud=1200, Data=8, Stop=1, Parity=Even, Protocol=3M n Digital Interface: Parity=None, Modality Group=0

8800 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: Density=16, Contrast=10 n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 575: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens MR Magnetom Jazz with Kodak DryView 8300 LASER IMAGER / Standalone

Keypad

Digital Board Data outputData Cable 37-pin

Siemens Magnetom Jazz MRDryView 8300

Requirements: n Siemens Magnetom Jazz MR rel. 5.4 n 8300 rel. 4.2 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16 n Contrast=10 n Sharp/Smooth=0

n on 8300 Service Menu into Configure User set: n Serial Control Interface: Protocol=Keypad n Digital Interface: Parity=Even (if error set to Disable) n Modality Group=0

Page 576: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Siemens MR Magnetom Jazz with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

3 M H Q L a s e r I m a g e r

Requirements: Magnetom Jazz rel. VA12A, M969 HQ rel. 5.1 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center M969 HQ Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 577: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens MR Magnetom Jazz with Kodak Digital Science 969 HQT LASER IMAGER

Keypad

Digital Board Data output

Data Cable 37-pin

Siemens Magnetom Jazz MR

M969 HQT

3 M H Q L a s e r I m a g e r

Requirements: Magnetom Jazz rel. VA12A, M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad M969 HQT Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMS, Contrast=15, Density=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 578: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Siemens MR Magnetom Jazz with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

XL Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Siemens Magnetom Jazz MR

3 M L a ser I m ag er

Requirements: Siemens Magnetom Jazz rel. VA12A, M959 XL rel. 3.8 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: n on XL Control Panel set Density & Contrast depending on chemistry n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center n on XL Input Module install LUT 322A0 M959 XL Setup: n on COMM Menu: 959 Default n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 579: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens MR Magnetom Jazz with Kodak DryView 8100 LASER IMAGER

Copper Cable

UKEIB

Keypad

Digital Board Data OUT

Keypad

Data Cable 37-pin

Siemens MRMagnetom Jazz

DryView 8100

Imager

RS422 9-pole Plug

Requirements: Magnetom Jazz rel. VA12A, 8100 v1.1 Note: on Magnetom Jazz Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=2 n on IMAGE QUALITY-> TFT FILES Menu: TFT=PMSB n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Even (if error Disable)

Page 580: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Siemens MR Magnetom Jazz with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Magnetom Jazz rel. VA12A Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board

by entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name= smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On

Data Cable 37-pin

Kodak MIM 200

Siemens MR Magnetom Jazz

Digital BoardData OUT

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 581: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape 160 Setup: no modality-specific setup needed

Page 582: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Siemens MR Magnetom Jazz with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Magnetom Jazz rel. VA12A Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Data Cable 37-pin

Kodak MIM 200

Siemens MR Magnetom Jazz

Digital BoardData OUT

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Fiber Cable

Page 583: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape 2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 584: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Siemens MR Magnetom Jazz with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Magnetom Jazz rel. VA12A Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Data Cable 37-pin

Kodak MIM 200

Siemens MR Magnetom Jazz

Digital BoardData OUT

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Fiber Cable

Page 585: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=CurveShape 1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 586: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Siemens MR Magnetom Jazz with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Magnetom Jazz rel. VA12A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM 200 Destinations Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On

Keypad

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

Fiber Cable

3M8700DryView

Kodak DryView 8700 Plus

RS422 37-to-50 pinDigital Adaptor Cable

Siemens MRMagnetom Jazz

Digital BoardData OUT

Data Cable 37-pin

Page 587: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsv3k.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 588: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Siemens MR Magnetom Jazz with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Magnetom Jazz rel. VA12A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Keypad

Siemens MRMagnetom Jazz

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

RS4229-pole Plug

Kodak DryView 8100

Digital BoardData OUT

Data Cable 37-pinRS422 37-to-50 pinDigital Adaptor Cable

Page 589: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsb.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 590: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Siemens MR Jazz via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens MRMagnetom Jazz

DryView 8300

DICOM Network

Requirements: n Siemens Magnetom Jazz platform Numaris Ortho rel. rel. VA13A (build 6.1F) n 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Contrast=10, Modality Group=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=104, Printer AE title=8300

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,10, Trim=YES (is always yes)

n in Menu: Help->Exposure set: Film Size=8x10, e.g., Division=6 (i.e., Format=6:1) n to acquire image on screen, press F9 or in Menu: Help->Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set:

n Modality Group=0

Page 591: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Siemens MR Jazz via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens MRMagnetom Jazz

DICOM Network

Kodak 190 camera

Requirements: Jazz MR platform Numaris Ortho rel. VA13A preliminary (build 6.1F) Requirements: 190 rel. 1.7.29 Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k190, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=190

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 592: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

MR Jazz via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens MRMagnetom Jazz

DryView 8700 Plus

9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film

Page 593: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interp.Type=831, Interp.Num=2 n Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=E_MRI_SCANNER, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 594: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

MR Jazz via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens MRMagnetom Jazz

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: 9410 v1.6, 8100 v2.4.1 Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interp.Type=831, Interp Num=2 n Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users:

Page 595: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n SCU AETitle=E_MRI_SCANNER, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 596: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

MR Jazz via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens MRMagnetom Jazz

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Contrast=10, Modality Group=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,10, Trim=YES (is always yes)

n in Menu: Help->Exposure set: Film Size=8x10, e.g., Division=6 (i.e., Format=6:1) n to acquire image on screen, press F9 or in Menu: Help->Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users:

Page 597: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

n SCU AETitle=E_MRI_SCANNER, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 598: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens MRMagnetom Jazz

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, KELI 160 v7.2 Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k160, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=160

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film

Page 599: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 434 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 160 Setup: no modality-specific setup needed

Page 600: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens MRMagnetom Jazz

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k2180, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=2180

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film

Page 601: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 602: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens MRMagnetom Jazz

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k1120, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=1120

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film

Page 603: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 604: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens MRMagnetom Jazz

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k8200, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8200

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 605: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 606: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens MRMagnetom Jazz

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8700

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film

Page 607: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 608: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens MRMagnetom Jazz

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8100

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, e.g., Division=20 (i.e., Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Page 609: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 610: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

MR Jazz via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens MRMagnetom Jazz

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, Contrast=10, Modality Group=0 Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8300

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,10, Trim=YES (is always yes)

n in Menu: Help->Exposure set: Film Size=8x10, e.g., Division=6 (i.e., Format=6:1) n to acquire image on screen, press F9 or in Menu: Help->Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film

Page 611: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 612: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

MR Jazz via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8900

n in Help/Service/Options/PrinterOption set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Info=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any

Siemens MRMagnetom Jazz

DICOM Network

Kodak DryView 8900

Page 613: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Pmsv3k.w87 (Always=Y) n Contrast= 9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=jazz

Page 614: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

MR Jazz via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: on Jazz MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=DV8150

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Info=LUT=0,9, Trim=YES (is always yes)

n in Help/Exposure set: Film Size=14x17, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F9 or in Help/Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On

Siemens MRMagnetom Jazz

DICOM Network

Kodak DryView 8150

Page 615: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 616: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

MR Jazz via DICOM with Kodak Color Medical Imager 1000

Requirements: Jazz MR platform Numaris Ortho rel. VA13A (build 6.1F) Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by Jazz MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K Magnetom Jazz MR Setup: n in Help/Service/Options/DICOM 3 Option set:

- Printer host name=CMI1000, Printer IP addr=accordingly - Printer TCP port=5040, Printer AE title=CMI1000

n in Help/Service/Options/Printer Option set (writing params with capital letters !): - Film Orientation=PORTRAIT, Medium Type=BLUE FILM - Film Destination=PROCESSOR, Magnification Type=CUBIC - Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK - Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Exposure set: Film Size=8x10, eg Division=6 (ie Format=6:1) n to acquire image on screen, press F9 or in Menu: Help->Exposure set: Expo Screen n automatic print after last F9 totally filled the film or in Help/Exposure: Print Film CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

Siemens MRMagnetom Jazz

DICOM Network

Kodak CMI 1000

Page 617: Siemens Setup Manuals

Siemens MR Jazz with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

n under Image Quality, Grayscale Image Quality: n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 618: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup Manual for Siemens MR Open / Vision / Impact with LASER IMAGERS

Important note: from mid 2000 MR models Harmony/Symphony/Sonata switched to the Numaris 4 syngo based platform (see setup there).

Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer.................................................. 3 n Kodak DryView 8700 LASER IMAGER / Plus............................................................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ....................................................... 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer.................................................. 6 n Kodak DryView 8500 LASER IMAGER / Plus............................................................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ....................................................... 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer.................................................. 9 n Kodak DryView 8300 LASER IMAGER /Standalone..................................................... 10 n Kodak Digital Science 969 HQ LASER IMAGER...................................................... 11 n Kodak Digital Science 969 HQT LASER IMAGER ................................................... 12 n Kodak Digital Science 959 XL LASER IMAGER ...................................................... 13 n Kodak DryView 8100 LASER IMAGER......................................................................... 14 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v 1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 15 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v 1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 17 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 19 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 21 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 23 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) .25 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4).................................................................... 27 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8900 LASER IMAGER ........................................................................ 29

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 619: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 31 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 32 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 33 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 35 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 37 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 39 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 41 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 43 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER(3,4,5)................................................................. 45 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 47 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 49 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 51 n Kodak DryView 8900 LASER IMAGER......................................................................... 53 n Kodak DryView 8150 LASER IMAGER......................................................................... 55 n Kodak Color Medical Imager 1000 ................................................................................. 57

Page 620: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens MR with Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8700 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-Input Manager

Requirements: SHPT rel. 1.3, 8800 rel. 4.2, 8700 rel. 1.15 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=XL, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on HOST Menu: Pixel Correct=Yes, Scale Format=Yes, Scale Magnif=Yes n on HOST Menu: Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2 n on EIB Menu: Parity=Disable, Timeout=50

Page 621: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens MR with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostSPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8700 Plus

3M 8700 DryView

Requirements: 8700 rel. 1.15 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8700 Plus Setup: n on COMM Menu: Siemens Default n on SIEMENS Menu: Modality=Magnetom, Timeout=50, Smooth Beta=2, Sharp Beta=2 n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=50

Page 622: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Siemens MR with Kodak DryView 8700 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8700 Standard

3M 8700 DryView

Requirements: 8700 rel. 1.15 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25

Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8700 Standard Setup: n on TDB/C board: Jumpers=RS232, Switch=Right n on COMM Menu: Siemens Default n on SIEMENS Menu: Modality=Magnetom, Timeout=50, Smooth Beta=2, Sharp Beta=2 n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=50

Page 623: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens MR with Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8500 LASER IMAGER / Dual Printer

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8500 DualFiber Cable

3M 8700 DryView3M8800Multi-In

putManager

Requirements: SHPT rel. 1.3, 8800 rel. 5.1, 8500 rel. 1.22 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=HQ, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on HOST Menu: Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2 n on EIB Menu: Parity=Disable, Timeout=50

Page 624: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Siemens MR with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8500 Plus

3M 8700 DryView

Requirements: SHPT rel. 1.3, 8500 rel. 1.22 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=HQ, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8500 Plus Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on HOST Menu: Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=50

Page 625: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens MR with Kodak DryView 8500 LASER IMAGER / Standard

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8500 Standard

3M 8700 DryView

Imager

Requirements: SHPT rel. 1.3, 8500 rel. 1.22 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=HQ, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Center n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on HOST Menu: Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=50

Page 626: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Siemens MR with Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8300 LASER IMAGER / Dual Printer

8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

3M8800Multi-InputManager

Requirements: SHPT rel. 1.3, 8800 rel. 5.1, 8300 rel. 4.4 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=16,LUT=10 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=HQ, Timeout=50 8300 Setup: (image quality proposed by Kodak) n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu: Serial: Baud=1200, Data=8, Stop=1, Parity=Even, Protocol=3M n on 8300 Service Menu: Digital Parity=None, Modality Group=0 8800 Setup: n UKEIB:ON/OFF/ON/OFF/OFF/ON,Switch=Right,on EIB:Parity=Disable,Timeout=50 n on COMM Menu: 959 Default; on IMAGE Menu:Density=16, Contrast=10 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on HOST Menu: Override 952 Beta=Yes, 831 Cmd Set Beta Tables: Horiz. Sharp=2

Page 627: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens MR with Kodak DryView 8300 LASER IMAGER / Standalone

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

ImagerHost

Siemens Host Protocol Translator

RS422 9-pinCopper Cable

SPCI

SPDI

Keypad

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

8300

Requirements: SHPT rel. 1.3, 8300 rel. 4.4 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=16,LUT=10 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=HQ, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8300 Setup: n on 8300 Operator Menu set:

n Density=16 n Contrast=10 n Film Layout : Format=1on 1, 2 on 1, 4 on 1, 6 on 1, Mode=Portrait

n on 8300 Service Menu set: n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8,

Nbr. of Stop bits=1, Parity=Even, Protocol=3M n Digital Interface: Parity=None n Modality Group=0 (note: image quality setup proposed by Kodak)

Page 628: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Siemens MR with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

3 M H Q L a s e r I m a g e r

Requirements: SHPT rel. 1.3, HQ rel. 4.2 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=6 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=HQ, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQ Setup: n on COMM Menu: 959 Default n on IMAGE Menu: (note: image quality setup proposed by Kodak)

n TFT=693C0, Dmax=3.00, Contrast=6, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu: Parity=Disable, Timeout=50

Page 629: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens MR with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQTRS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

3 M H Q L a s e r I m a g e r

Requirements: M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (e.g., you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with e.g., camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File HQ n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=4, LUT=11 and press Set Parameters into Exposure->Job Controller: press Continue

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25

Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQT Setup: n on TDB/C board: Jumpers=RS232, Switch=Right n on COMM Menu: Siemens Default n on SIEMENS Menu: Modality=Magnetom, Timeout=50 n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMSV3K, Contrast=11, Density=4, on OIC Menu: Chemistry=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=50

Page 630: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Siemens MR with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

3M L a ser I m ag er

Requirements: SHPT rel. 1.3, XL rel. 3.8 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (eg you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with eg camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File XL n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density & LUT depending on chemistry

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=XL, Timeout=50 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M959 XL Setup: n on COMM Menu: 959 Default n on EIB Menu: Parity=Disable, Timeout=50

Page 631: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens MR with Kodak DryView 8100 LASER IMAGER

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

DryView 8100

Imager

RS422 9-pole Plug

Requirements: SHPT v1.3, 8100 v1.1 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (eg you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with eg camera=3M 952 with SIB and reboot MR

Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=XL, Timeout=50 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=50, P1,…,P6=0 n Alarm=Old, Acquire Timeout=50, P1,…,P6=0

n on IMAGE QUALITY-> TFT FILES Menu: TFT=PMSB n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=2 n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Disable

Page 632: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Siemens MR with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

DPCCopper Cable

DPI4-to-DPC Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

Fiber Cable

Fiber Cable

25-9 DPC-UKEIB Cable

9410 PACS Link

3M 8700 DryView

DryView 8700 Plus

Requirements: SHPT v1.3, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras by basically

using the correspondent Model into 9410 Local Printers Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (eg you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with eg camera=3M 952 with SIB and reboot MR

Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom,Camera Type=XL, Timeout=50 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 633: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=50, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=mr, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8700, Film Destination=Processor, Printer1=8700(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Pmsv3k.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Dest.=Printer 1, Media Size=14x17, C=9, D=14 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 634: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Siemens MR with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens MR

DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Requirements: SHPT v1.3, 9410 v1.6, 8100 v2.4.1 Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (eg you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with eg camera=3M 952 with SIB and reboot MR.

Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9 and press Set Parameter into Exposure->Job Controller: press Continue

n on SHPT Service Screen set Modality=Magnetom, Camera Type=XL, Timeout=50 n on SHPT Service Screen set Sharp Beta=2, Smooth Beta=2 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 635: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=50, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=mr, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8100, Film Destination=Processor, Printer1=8100(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Pmsb.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=9, D=14 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 636: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Siemens MR via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens MR

SPCI

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Requirements: MIM 200 v6.1, KELI 160 v7.2 MR Setup: n on Siemens MR install Camera Config.File XLP n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System-> Camera: Density=265 (i.e., Dmax), LUT=3 (i.e., Curve Shape=3.0)

Contrast=500 (i.e., Film Contrast=0) and press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Vision: n Board/Channel=Digital Board 1 Channel 1, Logical Name=siemmr, n Mod.Name=mr, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 637: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 638: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Siemens MR via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens MR

SPCI

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Requirements: MIM 200 v6.1, KELP 2180 v2.17H MR Setup: n on Siemens MR install Camera Config.File XLP n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System-> Camera: Density=265 (i.e., Dmax), LUT=3 (i.e., Curve Shape=3.0)

Contrast=500 (i.e., Film Contrast=0) and press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Vision: n Board/Channel=Digital Board 1 Channel 1, Logical Name=siemmr, n Mod.Name=mr, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On

Page 639: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 640: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Siemens MR via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens MR

SPCI

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 MR Setup: n on Siemens MR install Camera Config.File XLP n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System-> Camera: Density=265 (i.e., Dmax), LUT=3 (i.e., Curve Shape=3.0)

Contrast=500 (i.e., Film Contrast=0) and press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Vision: n Board/Channel=Digital Board 1 Channel 1, Logical Name=siemmr, n Mod.Name=mr, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On

Page 641: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 642: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Siemens MR via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens MR

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Fiber Cable

3M 8700 DryView

Kodak DryView 8700 Plus

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM 200 Destinations and if HQ by installing HQ into Siemens Camera Config.File

MR Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Vision:

n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Mod.Name=smr, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=2, Interpolation Smooth=2

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60

Page 643: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Pmsv3k.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 644: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

Siemens MR via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens MR

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25-to-25 NullModem Cable COPCIL Board

Copper Cable

Control 9-pin

Data 37 pin

Kodak DryView 8100

RS4229-pole Plug

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: MIM200 v6.1, 8100 v2.4.1 MR Setup: n on Siemens MR install Camera Config.File DRYVIEW (if not available HQ) n on Siemens MR to set Density and Contrast for the Camera:

into Exposure->Job Controller: press Stop into System->Camera: set Density=14, LUT=9

into System->Camera: press Set Parameters into Exposure->Job Controller: press Continue

MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Vision: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Mod.Name=smr, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=2, Interpolation Smooth=2 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Page 645: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Pmsb.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 646: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Siemens MR via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8900 LASER IMAGER

Requirements: MIM200 v6.1 Requirements: 8900 release 2.0 (ie DRE v2.00.b3, MIM v5.6.b3, MCS v2.00) Note: on some old MR, if you want to configure a new camera because you are replacing an

existing one (eg you are replacing a Kodak wet with a 3M dry camera), first you have to uninstall the old camera i.e., on Siemens MR configure MR with camera=None, boot MR like this, and then install the new camera i.e., on Siemens MR configure MR with eg camera=3M 952 with SIB and reboot MR

MR Setup: n on Siemens CT install Camera Config.File Kodak 2180 (or XLP) n on Siemens CT to set Density and Contrast for the Camera: into Exposure->Job Controller: press Stop into System->Camera: set Density=265 (ie Dmax),

LUT=3 (ie Curve Shape=3.0) Contrast=500 (ie Film Contrast=0) and press Set Parameters

into Exposure->Job Controller: press Continue MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

ie delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.= Somatom Power:

n Board/Channel=Digital Board 1 Channel 1, Logical Name= sct, n Mod.Name=sct, Primary Control: Type= Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=512, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1

n on Configure, Destination, Add, Print, Network, Qualified, 8900, Set:

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

Siemens MR

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25-to-25 NullModem Cable

Kodak DryView 8900

Kpad / Host Control Octopus Adaptor Cable

DICOM Network

Page 647: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n General: Log.Name=8900, IPAddr=accordingly n General: Database=8900, Model=8900, Memory=32 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n DICOM Info: Protocol=DICOM 3.0, Service Class=Basic Grayscale Print n DICOM Info: Port=5040,AETitle=NER_8900,Counter=40,Response=100 n Supported Items: Collation=On, Common Text=On, Tonescaling=On n Supported Items: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnif=On, Bilinear=On, Replic=On, Cubic Spline=On n Interpolation: Cubic Convolution 2=On, Cubic Convolution 3=On n Format Types: Custom Formats=On, Row Symm.=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.3 n SCU: Luminance Space= On, Variable Border Density=On n SCU: Curve Shape=On, Perception LUT =On, PLUT Service=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8900, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsv3k.w87, Auto Study=Off, Console=On, Annotation=Off

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any

Page 648: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Pmsv3k.w87 (Always=Y) n Contrast= 9 (Always=Y), Smoothing Type=2 (Always=Y) n Dmin=0.00 (Always=N), Dmax= 3.00 (Always=Y) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mr

Page 649: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Siemens MR Open/Vision/Impact via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens MR- Harmony/Symphony ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

DryView 8300

DICOM Network

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300 and on 8300 use D=16, C=10, Modality Group=0 b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera

in this case use Dmax=300 and on 8300 use D=16, C=1, Modality Group=4 Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=8300, Port=104 n on MR into System/Run/DICOM Basic Print Configuration set:

Matrix=512 (if this field is not available, 512 is default i.e., already set) Filmsize=8x10, Orient=Portrait, Format=eg 3x2 Add, Density=300 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth) 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 10 or b) 1, Sharp/Smooth=0 i.e., Auto n Film Layout : Format=1 on 1, Mode=Portrait, 2:1P, 4:1P, 6:1P n on 8300 Service Menu into Configure User set: Modality Group=a) 0 or b) 4

Page 650: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

Siemens MR Open/Vision/Impact via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens MR- Harmony/Symphony ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

DICOM Network

Kodak 190 camera

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 190 rel. 1.7.29 Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, Curve Shape=3.0, Film Contrast=0 (use a) configuration in case also a Virtuoso workstation is printing on same camera)

b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case use Dmax=265, Curve Shape=0.0, Film Contrast=0

Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=190, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth) 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=a) 3.00 or b) 2.65, Curve Shape=a) 3.0 or b) 0.0, Contrast=0 n Contrast Pivot Density=1.2, IPAddress=accordingly n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 651: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens MR- Harmony/Symphony ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

DryView 8700 Plus

9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, C=9, TFT=PMSV3K b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=260, C=4, TFT=WRKSTN2A Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=9410, Port=1024 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 652: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=8, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interp.Type=831, Interp.Num=2 n Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 9 or b) 4 n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 n Max.Density=a) 300 or b) 260, Border=0, Mag.Type=8, Smoothing=2 (or 13) n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=8, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 653: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens MR- Harmony/Symphony ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 9410 v1.6, 8100 v2.4.1 Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, C=9, TFT=PMSB b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=260, C=2, TFT=WRKSTN2A MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=9410, Port=1024 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient.=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 654: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 9 or b) 2 n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 n Max.Density=a) 300 or b) 260, Border=0, Mag.Type=8, Smoothing=2 (or 13) n Polarity=1, Orientation=1, Req.Image Size=0, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 655: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens MR- Harmony/Symphony ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300 and on 8300 use D=16, C=10, Modality Group=0 b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=300 and on 8300 use D=16, C=1, Modality Group=4 MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=9410, Port=1024 n on MR into System/Run/DICOM Basic Print Configuration set:

Matrix=512 (if this field is not available, 512 is default i.e., already set) Filmsize=8x10, Orient.=Portrait, Format=eg 3x2 Add, Density=300 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 656: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 10 or b) 1 n TFT/ULUT=a) u1_109b.w8u or b) wrkstn83a.w8u n Max.Density=300, Border=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 657: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, KELI 160 v7.2 Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, Curve Shape=3.0, Film Contrast=0 b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=265, Curve Shape=0.0, Film Contrast=0 Harmony/Symphony/Sonata or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=160, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 658: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 659: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens MR- Harmony/Symphony

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200 Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, 2180 v2.17H Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, Curve Shape=3.0, Film Contrast=0 b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=265, Curve Shape=0.0, Film Contrast=0 Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=2180, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 660: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 661: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens MR- Harmony/Symphony

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200 Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, Curve Shape=3.0, Film Contrast=0 b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=265, Curve Shape=0.0, Film Contrast=0 Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=1120, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 662: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 663: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata ie Numaris 3.5 platform- Open/Vision/Impact ie Numaris 3 platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, C=9, TFT=PMSB b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=265, C=4, TFT=WRKSTN2A Harmony/Symphony/Sonata or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=8200, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On

Page 664: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +9 or b) +4 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 665: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens MR- Harmony/Symphony/Sonata

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, C=9, TFT=PMSV3K b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=260, C=4, TFT=WRKSTN2A Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=8700, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 666: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 9 or b) 4 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (or 13) (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 667: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens MR- Harmony/Symphony/Sonata

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300, C=9, TFT=PMSB b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=260, C=2, TFT=WRKSTN2A MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=8100, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient.=Portrait, Transfer Matrix=1024 Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth) MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 668: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 9 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (or 13) (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 669: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

Siemens MR Open/Vision/Impact via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens MR- Harmony/Symphony

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 a) if LUT=10 then Image Data not lutted by MR, lutted by Camera in this case use

Dmax=300 and on 8300 use D=16, C=10, Modality Group=0 b) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera in this case

use Dmax=300 and on 8300 use D=16, C=1, Modality Group=4 MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=8300, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Matrix=512 (if this field is not available, 512 is default i.e., already set) Filmsize=8x10, Orient.=Portrait, Format=eg 3x2 Add, Density=300 a) LUT=10 (i.e., Image Data not lutted by MR, lutted by Camera) b) LUT=1 (i.e., Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (i.e., smooth)

Page 670: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Admin, Update SCU Connection Database, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) u1_109b.w8u or b) wrkstn2a.w8u (Always=Y) n Contrast (dry)=a) 10 or b) 1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 671: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

Siemens MR Open/Vision/Impact via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 c) if LUT=10 then Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB d) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera

in this case use Dmax=260, C=4, TFT=WRKSTN2A Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=8900, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024, Format=eg 5x4 Add, Density=a) 300 or b) 265 a) LUT=10 (ie Image Data not lutted by MR, lutted by Camera) b) LUT=1 (ie Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (ie smooth) 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On

Siemens MR- Harmony/Symphony/Sonata

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

DICOM Network

Kodak DryView 8900

Page 672: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30 n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify:

n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 9 or b) 4 (Always=Y), n Smoothing Type=2 (or 13) (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mr

Page 673: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 56

Siemens MR Open/Vision/Impact via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: MR Numaris 3.5 rel. VA13A or MR Numaris 3 rel. VB33A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 e) if LUT=10 then Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB f) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera

in this case use Dmax=300, C=1, TFT=WRKSTN2A Harmony/Symphony or Open/Vision/Impact MR Setup: n on MR into System/Service declare camera IP Addr, AE Title=DV8150, Port=5040 n on MR into System/Run/DICOM Basic Print Configuration set:

Filmsize=14x17, Orient=Portrait, Transfer Matrix=1024, Format=eg 5x4 Add, Density=300 a) LUT=10 (ie Image Data not lutted by MR, lutted by Camera) b) LUT=1 (ie Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (ie smooth) 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On

Siemens MR- Harmony/Symphony/Sonata

ie Numaris 3.5 platform- Open/Vision/Impact

ie Numaris 3 platform

DICOM Network

Kodak DryView 8150

Page 674: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 57

n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=a) Pmsb.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast=a) 9 or b) 1 (Always=Y),Smoothing Type=2 (or 13) (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 675: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 58

Siemens MR Open/Vision/Impact via DICOM with Kodak Color Medical Imager 1000

Requirements: MR Numaris 3 rel. VB33A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Siemens MR could be configured with a) LUT=10 or b) LUT=1 g) if LUT=10 then Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB h) if LUT=1 then Image Data lutted by MR, linear-in-Density LUT into Camera

in this case use Dmax=300, C=7, TFT=WRKSTN2A MR Setup: n on MR into System/Service declare camera IP Addr, AE Title, Port n on MR into System/Run/DICOM Basic Print Configuration set:

Matrix=512 (if this field is not available, 512 is default ie already set) Filmsize=8x10, Orient.=Portrait, Format=eg 3x2 Add, Density=300 a) LUT=10 (ie Image Data not lutted by MR, lutted by Camera) b) LUT=1 (ie Image lutted by MR, linear-in-Density LUT in Camera)

n on MR into Exposure/Settings set Graduation=smt (ie smooth) CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 9 or b) 7 (Always=Y)

DICOM Network

Kodak CMI 1000

Siemens MR- Open/Vision/Impact

ie Numaris 3 platform

Page 676: Siemens Setup Manuals

Siemens MR platform Numaris 3, based on SUN with some LASER IMAGER Products

Author: [email protected], Edition: May ´05 59

n TFT Set (From list)=a) Pmsv3k.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (or 13) (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 677: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens Nuc.Med. e.soft with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22 n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 678: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Nuc.Med. e.soft via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8300

DICOM Network

Requirements: e.soft v3.5 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2736x2136 (since Landscape), Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: NM Image=a) linear or b) NM, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 4 or b) 1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=a) 2 or b) 4

Page 679: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Nuc.Med. e.soft via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens e.softNuc. Med. workstationsyngo platform

DICOM Network

Kodak 190 camera

Requirements: e.soft v3.5 Requirements: 190 rel. 1.7.29 Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=4.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : NM Image=a) linear or b) NM, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=a) 4.0 or b) 0.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 680: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Nuc.Med. e.soft via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: e.soft v3.5 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and if HQ by installing HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=3, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: NM Image=a) linear or b) NM, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber

Page 681: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 15 or b) 3 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Density=14, Dmax=3.00, Contrast=6 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 682: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Nuc.Med. e.soft via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: e.soft v3.5 Requirements: 9410 v1.6, 8100 v2.4.1 Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=3, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: NM Image=a) linear or b) NM, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Page 683: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 15 or b) 3 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 684: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Nuc.Med. e.soft via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: e.soft v3.5 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: NM Image=a) linear or b) NM, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

Page 685: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 4 or b) 1 n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 686: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=4.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30,

Page 687: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 4 i.e., 575 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 688: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens e.softNuc. Med. workstationsyngo platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, 2180 v2.17H Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=4.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180

Page 689: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 4 i.e., 575 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 690: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens e.softNuc. Med. workstationsyngo platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, 1120 v2.40/032 Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=4.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120

Page 691: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 4 i.e., 575 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 692: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=3, TFT=WRKSTN2A

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

Page 693: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +15 or b) +3 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 694: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and if HQ by installing HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=3, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly

Page 695: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Admin, Update SCU Connection Database, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 15 or b) 3 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 696: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=3, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 697: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Admin, Update SCU Connection Database, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 15 or b) 3 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 698: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Nuc.Med. e.soft via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens e.softNuc. Med. workstationsyngo platform

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: e.soft v3.5 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: NM Image=a) linear or b) NM, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

Page 699: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u (Always=Y) n Contrast (dry)=a) 4 or b) 1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n ICCProfile=Off (Always=N), Modality=OT (Always=N) n BodyPart=Default (Always=N), Modality Group=1 n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Conv.Group=1, Gamma Table=1, Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 700: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Nuc.Med. e.soft via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: e.soft v3.5 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: syngo could be configured with a) LUT=linear or b) LUT=NM a) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set Usage of Presentation LUT=disabled NM Image=a) linear (if not there, choose nothing selected) or b) NM SC Image=a) linear (if not there, choose nothing selected) or b) NM Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

Siemens e.softNuc. Med. workstationsyngo platform

DICOM Network

Kodak DryView 8900

Page 701: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 15 or b) 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=esoft

Page 702: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Nuc.Med. e.soft via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: e.soft v3.5 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: syngo could be configured with a) LUT=linear or b) LUT=NM c) into Local Service/Config/DICOM LUT files set NM Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

d) into Local Service/Config/DICOM LUT files set NM Image=NM, MaxDens=3.00 if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150,Type=DICOM Printer, Class=kodak8150(or kodak8200),

DICOM Node=kodak8150, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set Usage of Presentation LUT=disabled NM Image=a) linear (if not there, choose nothing selected) or b) NM SC Image=a) linear (if not there, choose nothing selected) or b) NM Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM

Siemens e.softNuc. Med. workstationsyngo platform

DICOM Network

Kodak DryView 8150

Page 703: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast=a) 15 or b) 1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=esoft

Page 704: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Nuc.Med. e.soft via DICOM with Kodak Color Medical Imager 1000

Requirements: e.soft v4.0 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: syngo could be configured with a) LUT=linear or b) LUT=NM e) into Local Service/Config/DICOM LUT files set NM Image=linear

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=15, TFT=SIEFL87B

f) into Local Service/Config/DICOM LUT files set NM Image=NM if LUT=NM then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=7, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set NM Image=a) linear or b) NM, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000

DICOM Network

Kodak CMI 1000

Siemens e.softNuc. Med. workstationsyngo platform

Page 705: Siemens Setup Manuals

Siemens Nuc.Med. model e.soft with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 15 or b) 7 (Always=Y) n TFT Set (From list)=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 706: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens Nuc.Med. ICON with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22 n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 707: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens ICON via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8300

DICOM Network

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8300 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=8300, Port=104 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set: Modality Group=0

Page 708: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens ICON via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens ICONNuc. Med. workstationMcIntosh platform

DICOM Network

Kodak 190 camera

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 190 rel. 1.7.29 Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=k190 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=190, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 709: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens ICON via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8700 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=9410, Port=1024 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers:

Page 710: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Printer=8700, AE Title=9410, Port=1024, Max Associations=5 on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Density=14, Dmax=3.00, Contrast=6 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 711: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens ICON via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 9410 v1.6, 8100 v2.4.1 Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8100 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=9410, Port=1024 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly

Page 712: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 713: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens ICON via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8300 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=9410, Port=1024 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly

Page 714: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 715: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, KELI 160 v7.2 Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=k160 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=160, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On

Page 716: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 717: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, 2180 v2.17H Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=k2180 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=2180, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue)

Page 718: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 719: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, 1120 v2.40/032 Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=k1120 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=1120, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue)

Page 720: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 721: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8200 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=8200, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear)

Page 722: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 723: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8700 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=8700, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700

Page 724: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Admin, Update SCU Connection Database, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 725: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8100 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=8100, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Page 726: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Admin, Update SCU Connection Database, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 727: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Siemens ICON via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens ICONNuc. Med. workstationMcIntosh platform

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8300 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=8300, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Page 728: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=u1_109b.w8u (Always=Y), Contrast (dry)=10 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 729: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Siemens ICON via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8900 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=8900, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On

Siemens ICONNuc. Med. workstationMcIntosh platform

DICOM Network

Kodak DryView 8900

Page 730: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= Pmsv3k.w87 (Always=Y) n Contrast= 9 (Always=Y), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=icon

Page 731: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Siemens ICON via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W n set Host Name=dv8150 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=DV8150, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

Siemens ICONNuc. Med. workstationMcIntosh platform

DICOM Network

Kodak DryView 8150

Page 732: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=Y), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=icon

Page 733: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Siemens ICON via DICOM with Kodak Color Medical Imager 1000

Requirements: Siemens ICON v6.0.3, Dicom Link v1.3 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Image Data not lutted by Siemens ICON, lutted by Camera ICON Setup: n into DICOMtools folder, double-click DICOMlink application icon n into Configuration/Remote Nodes/New set Service=Print B/W (or Color) n set Host Name=CMI1000 n (note: remember in System Folder into Hosts file to map Host Name=IPaddress) n set Application AE=CMI1000, Port=5040 from ICON application: n into File/Print: Copies=1, Interpolation=Cubic n into File/Page Setup: Polarity=Normal, Orientation=Landscape n into File/Page Setup: minD=0.20, maxD=3.00, Format=1:1 n into File/Page Setup: border=Black, empty=Black n into File/Page Setup: DPI=don’t care, use doc window size=don’t care CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

DICOM Network

Kodak CMI 1000

Siemens ICONNuc. Med. workstationMcIntosh platform

Page 734: Siemens Setup Manuals

Siemens Nuc.Med. ICON with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Contrast=9 (Always=Y) n TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 735: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens workstation Leonardo with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ............................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 736: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens Leonardo via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens LeonardoWorkstationsyngo platform

DryView 8300

DICOM Network

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=104 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=a) 4 or b) 1, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set: Modality Group=a) 2 or b) 4

Page 737: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens Leonardo via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens LeonardoWorkstationsyngo platform

DICOM Network

Kodak 190 camera

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: 190 rel. 1.7.29 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k190, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k190, Host Sel.=k190, AE Title=190, Port=5040 press button Save and then press button Verification step 3: HC Device=k190, Type=DICOM Printer, Class=kodak190,

DICOM Node=k190, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5120, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=a) 3.0 or b) 0.0, Contrast=0, n Contrast Pivot Density=1.2, IPAddress=accordingly, n Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 738: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Leonardo via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens LeonardoWorkstationSyngo platform

DryView 8700 Plus

9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

Page 739: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=a) 4 or b) 2 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 740: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Leonardo via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens LeonardoWorkstationSyngo platform

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: 9410 v1.6, 8100 v2.4.1 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831

Page 741: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Interp Num=0, Max.Density=300, Contrast=6, Border=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=a) 4 or b) 2 n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 742: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Leonardo via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens LeonardoWorkstationsyngo platform

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=9410, Port=1024 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831

Page 743: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=a) 4 or b) 1 n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 744: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens LeonardoWorkstationsyngo platform

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak 160 camera

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, KELI 160 v7.2 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=434 (i.e., 3.0), Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k160, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k160, Host Sel.=k160, AE Title=160, Port=5040 press button Save and then press button Verification step 3: HC Device=k160, Type=DICOM Printer, Class=kodak160,

DICOM Node=k160, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5348, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 745: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 746: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens LeonardoWorkstationsyngo platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, 2180 v2.17H Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k2180, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k2180, Host Sel.=k2180, AE Title=2180, Port=5040 press button Save and then press button Verification step 3: HC Device=k2180, Type=DICOM Printer, Class=kodak2180,

DICOM Node=k2180, Pixel Size=79x79, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5156, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 747: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 748: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens LeonardoWorkstationsyngo platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, 1120 v2.40/032 Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, Curve Shape=0.0, Film Contrast=0

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=kodak1120, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak1120, Host Sel.=kodak1120, AE Title=1120, Port=5040 press button Save and then press button Verification step 3: HC Device=kodak1120, Type=DICOM Printer, Class=kodak1120,

DICOM Node=kodak1120, Pixel Size=80x80, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4096x5132, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 749: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=a) 3 i.e., 434 or b) 0.0 (Always=Y) n Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 750: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens LeonardoWorkstationsyngo platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=k8200, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=k8200, Host Sel.=k8200, AE Title=8200, Port=5040 press button Save and then press button Verification step 3: HC Device=k8200, Type=DICOM Printer, Class=kodak8200,

DICOM Node=k8200, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=e.g., Inch14x17, Size/Pixel=4360x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set : XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 751: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) +4 or b) +2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 752: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens LeonardoWorkstationsyngo platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into syngo DICOM Camera Config.File

Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8700, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8700, Host Sel.=dv8700, AE Title=8700, Port=5040 press button Save and then press button Verification step 3: HC Device=dv8700, Type=DICOM Printer, Class=imation8700,

DICOM Node=dv8700, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5220, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup:

Page 753: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 4 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 754: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens LeonardoWorkstationsyngo platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

b) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8100, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8100, Host Sel.=dv8100, AE Title=8100, Port=5040 press button Save and then press button Test step 3: HC Device=dv8100, Type=DICOM Printer, Class=imation8100,

DICOM Node=dv8100, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4096x5216, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Page 755: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast (dry)=a) 4 or b) 2 (Always=Y) n ImageDmin=0.00 (Always=N), ImageDmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 756: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Leonardo via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens LeonardoWorkstationsyngo platform

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: syngo could be configured with a) LUT=linear or b) LUT=xa a) into Local Service/Config/DICOM LUT files set XA Image=linear, MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use D=16, C=4, Modality Group=2

b) into Local Service/Config/DICOM LUT files set set XA Image=xa, MaxDens=3.00 if LUT=xa then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use D=16, C=1, Modality Group=4

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8300, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=dv8300, Host Sel.=dv8300, AE Title=8300, Port=5040 press button Save and then press button Test step 3: HC Device=dv8300, Type=DICOM Printer, Class=imation8300,

DICOM Node=dv8300, Pixel Size=85x85, Film Sheet Formats: Inch8x10, it appears media sheet size=Inch8x10, Size/Pixel=2256x2676, Medium Type=Blue Film, Film Destination=Processor, press button Save

n into Local Service/Config/DICOM LUT files set: XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add:

Page 757: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On, Landscape=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=a) 693c0.w8u or b) wrkstn83a.w8u (Always=Y) n Contrast (dry)=a) 4 or b) 1 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 758: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Leonardo via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Leonardo syngo platform rel. VD10A 2004A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: syngo could be configured with a) LUT=linear or b) LUT=xa c) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

d) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=2, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8900, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8900, Host Sel.=dv8900, AE Title=8900, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8900, Type=DICOM Printer, Class=kodak8900_smallB

(or kodak8900 and in this case 2mm Border=No, or kodak8200), DICOM Node=kodak8900, Pixel Size=78x78, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4448x5306, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM

Siemens LeonardoWorkstationsyngo platform

DICOM Network

Kodak DryView 8900

Page 759: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT/ULUT= a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 4 or b) 2 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=leo

Page 760: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Leonardo via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Leonardo syngo platform VB30B Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: syngo could be configured with a) LUT=linear or b) LUT=xa e) into Local Service/Config/DICOM LUT files set XA Image=linear , MaxDens=3.00

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

f) into Local Service/Config/DICOM LUT files set XA Image=xa, MaxDens=3.00 if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=1, TFT=WRKSTN2A

syngo Setup: n into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=dv8150, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=kodak8150, Host Sel.=dv8150, AE Title=DV8150, Port=5040 press button Save and then press button Verification step 3: HC Device=ek8150, Type=DICOM Printer,Class=kodak8150,

DICOM Node=kodak8150, Pixel Size=78.12x78.12, Film Sheet Formats: Inch14x17, it appears media sheet size=Inch14x17, Size/Pixel=4438x5390, Medium Type=Blue Film, Film Destination=Processor, press button Save

- into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM

Siemens LeonardoWorkstationsyngo platform

DICOM Network

Kodak DryView 8150

Page 761: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name= a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Contrast= a) 4 or b) 1 (Always=Y), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=leo

Page 762: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Leonardo via DICOM with Kodak Color Medical Imager 1000

Requirements: Leonardo platform syngo VD30A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: syngo could be configured with a) LUT=linear or b) LUT=xa g) into Local Service/Config/DICOM LUT files set XA Image=linear

if LUT=linear then Image Data not lutted by syngo, lutted by Camera in this case use Dmax=300, C=4, TFT=SIEFL87B

h) into Local Service/Config/DICOM LUT files set XA Image=xa if LUT=ax then Image Data lutted by syngo, linear-in-Density LUT into Camera in this case use Dmax=300, C=7, TFT=WRKSTN2A

syngo Setup: - into Local Service/Config/DICOM Hardcopy Devices declare: step 1: Host Name=cmi1000, IP Addr=accordingly, press button Test, press Save step 2: Log.Name=ek1000, Host Sel.=cmi1000, AE Title=CMI1000, Port=5040 press button Save and then press button Test step 3: HC Device=kodak1000, Type=DICOM Printer,

Class=kodakCMI1000 (or imation8300), DICOM Node=ek1000, Pixel Size=81x81, Film Sheet Formats: A4 (or A), it appears media sheet size=A4 (or A), Size/Pixel=2508x3134 (or 2508x2954), Medium Type=Paper, Film Destination=Processor, color appearance=Color 24 bit (or Grayscale 8 bit), background=white, Transformation=no magnification, press button Save

- into Local Service/Config/DICOM LUT files set XA Image=a) linear or b) xa, Max Density=3.00 XRF Image=a) linear or b) xrf, Max Density=3.00 XABiPlane Image=a) linear or b) xabipl, Max Density=3.00

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly

DICOM Network

Kodak CMI 1000

Siemens LeonardoWorkstationsyngo platform

Page 763: Siemens Setup Manuals

Siemens workstation Leonardo with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=a) 4 or b) 7 (Always=Y) n TFT Set (From list)=a) Siefl87b.w87 or b) Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 764: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens workstation MagicView 300 with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ............................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ............................. 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 765: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Siemens Magicview 300 via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens MagicView 300

Kodak DryView 8300

DICOM Network

Requirements: Siemens Magicview 300 rel. VA30B Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8300, Alias=Kodak DV8300, AET=8300 TCP/IP: Host =PC-name of DV8300, Port=104, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8300, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=0, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of DV8300 must be inserted in hosts of MV300 PC 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=Auto n Film Layout : Format=1 on 1, Mode=Portrait, 2:1P, 4:1P, 6:1P n on 8300 Service Menu into Configure User set: Modality Group=0

Page 766: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens MagicView 300 via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens MagicView 300

DICOM Network

Kodak 190 camera

Requirements: Siemens MagicView 300 rel. VA30B, 190 rel. 1.7.29 Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 190, Alias=Kodak MLP190, AET=190 TCP/IP: Host =PC-name of MLP190, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak MLP190, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of MLP190 must be inserted in hosts of MV300 PC 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=30.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 767: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

MagicView 300 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens MagicView 300

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siemens MagicView 300 rel. VA30B, 9410 v1.6, 8700 v1.34 Note: Image Data not lutted by MV300, lutted by Camera Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into MagicView Camera Config.File

MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Network Names: Printer Type=Kodak 8700, Alias=Kodak DV8700, AET=9410 TCP/IP: Host =PC-name of 9410, Port=1024, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8700, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of 9410 must be inserted in hosts of MV300 PC

Page 768: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=dv8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=dv8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=dv8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 769: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

MagicView 300 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens MagicView

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siemens MagicView 300 rel. VA30B, 9410 v1.6, 8100 v2.4.1 Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Network Names: Printer Type=Kodak 8100, Alias=Kodak DV8100, AET=9410 TCP/IP: Host =PC-name of 9410, Port=1024, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8100, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of 9410 must be inserted in hosts of MV300 PC

Page 770: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 771: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

MagicView 300 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens MagicView 300

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Siemens MagicView 300 rel. VA30B Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8300, Alias=Kodak DV8300, AET=9410 TCP/IP: Host =PC-name of 9410, Port=1024, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8300, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=0, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of 9410 must be inserted in hosts of MV300 PC

Page 772: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 773: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens MagicView 300

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, KELI 160 v7.2 Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Network Names: Printer Type=Kodak 160, Alias=Kodak KELI160, AET=160 TCP/IP: Host =PC-name of MIM200, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak KELI160, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of MIM200 must be inserted in hosts of MV300 PC

Page 774: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 434 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 775: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens MagicView 300

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200 Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, 2180 v2.17H Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 2180, Alias=Kodak KELP2180, AET=2180 TCP/IP: Host =PC-name of DPS, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak KELP2180, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of DPS must be inserted in hosts of MV300 PC

Page 776: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 434 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 777: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens MagicView 300

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 1120, Alias=Kodak KELP1120, AET=1120 TCP/IP: Host =PC-name of DPS, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak KELP1120, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of DPS must be inserted in hosts of MV300 PC

Page 778: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e., 434 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 779: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens workstationMagicView 300

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Network Names: Printer Type=Kodak 8200,Alias=Kodak DV8200,AET=8200 TCP/IP: Host =PC-name of MIM200, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8200, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retri.e.,s=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of MIM200 must be inserted in hosts of MV300 PC MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32

Page 780: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 781: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens workstationMagicView 300

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into MagicView Camera Config.File

Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8700, Alias=Kodak DV8700, AET=8700 TCP/IP: Host =PC-name of MIM200, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8700, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of MIM200 must be inserted in hosts of MV300 PC

Page 782: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 783: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens workstationMagicView 300

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8100, Alias=Kodak DV8100, AET=8100 TCP/IP: Host =PC-name of MIM200, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8100, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of MIM200 must be inserted in hosts of MV300 PC MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 784: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 785: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

MagicView 300 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens workstationMagicView 300

Kodak DryView 8300

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siemens MagicView 300 rel. VA30B Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8300, Alias=Kodak DV8300, AET=8300 TCP/IP: Host =PC-name of MIM200, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8300, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=0, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of MIM200 must be inserted in hosts of MV300 PC MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32

Page 786: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 787: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

MagicView 300 via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Siemens MagicView 300 rel. VA40A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8900 (or 8100), Alias=Kodak DV8900, AET=8900 TCP/IP: Host =PC-name of 8900, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8900, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of 8900 must be inserted in hosts of MV300 PC 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any

Siemens workstationMagicView 300

DICOM Network

Kodak DryView 8900

Page 788: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=Y), Contrast=9 (Always=Y) n Smoothing Type=11 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mv300

Page 789: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

MagicView 300 via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Siemens MagicView 300 rel. VA40A Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak 8150 (or 8100),Alias=Kodak DV8150,AET=DV8150 TCP/IP: Host =PC-name of 8150, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak DV8150, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of 8150 must be inserted in hosts of MV300 PC 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On

Siemens workstationMagicView 300

DICOM Network

Kodak DryView 8150

Page 790: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10 n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mv300

Page 791: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

MagicView 300 via DICOM with Kodak Color Medical Imager 1000

Requirements: Siemens MagicView 300 rel. VA40A Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Image Data not lutted by MV300, lutted by Camera MagicView 300 Setup: - into Patient/Settings - Create New - into Network set (note: choose the camera from the Printer Type list):

Names: Printer Type=Kodak CMI1000, Alias=Kodak CMI1000, AET=CMI1000 TCP/IP: Host =PC-name of CMI1000, Port=5040, DNS/WINS=clicked

- Save - into Film Sheet set:

Film Job: Printer Alias=Kodak CMI1000, Medium Type=BLUE FILM Sheet: Magnif=CUBIC, Smooth=11, Border=BLACK, Empty=BLACK, Trim=NO

- into Advanced set: Nbr.Retries=5, Print Retry Delay=180, Print Timeout=300, Refresh=180 Enable Hospital Information=not clicked

- note: when Camera Config. is completed, select the camera from the Alias list - note: IP-addr and PC-name of CMI1000 must be inserted in hosts of MV300 PC CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

DICOM Network

Kodak CMI 1000

Siemens workstationMagicView 300

Page 792: Siemens Setup Manuals

Siemens workstation MagicView 300 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n under Image Quality, Grayscale Image Quality: n Contrast=9 (Always=Y) n TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=11 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 793: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Siemens workstation MagicView 1000 with LASER IMAGERS Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual.......................................................................... 3 n Kodak DryView 8700 LASER IMAGER / Plus .......................................................................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ................................................................... 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual.......................................................................... 6 n Kodak DryView 8500 LASER IMAGER / Plus .......................................................................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ................................................................... 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual.......................................................................... 9 n Kodak DryView 8300 LASER IMAGER / Standalone................................................................ 10 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual / Kodak DryView 8300 LASER IMAGER / Dual.......................................................................... 11

n Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8700 LASER IMAGER / Dual / Kodak DryView 8500 LASER IMAGER / Dual.......................................................................... 12

n Kodak DryView 8800 MULTI-INPUT MANAGER / Kodak DryView 8500 LASER IMAGER / Dual / Kodak DryView 8300 LASER IMAGER / Dual.......................................................................... 13

n Kodak Digital Science 969 HQ LASER IMAGER.................................................................. 14 n Kodak Digital Science 969 HQT LASER IMAGER ............................................................... 15 n Kodak Digital Science 959 XL LASER IMAGER.................................................................. 16 n Kodak DryView 8100 LASER IMAGER..................................................................................... 17 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ........................................... 18

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1)................................................................................ 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ............................................................................. 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .......................................................................... 24

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .......................................................................... 26

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) ........... 28

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4)......................................................................... 30

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 794: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER..................................................................................... 32 n Kodak Digital Science 190 MEDICAL LASER PRINTER .................................................... 33 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual,8500 Plus, 8800/8500 Dual and HQ) (1) ............................................ 34

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER (1)................................................................................ 36

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER (1)................................................................................ 38

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ........................................................................................................................ 40

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ............................................................................. 42

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .......................................................................... 44

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .......................................................................... 46

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)..................................................................... 48

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (4,5) ..................................... 50

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5)....................................................................... 52

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5)....................................................................... 54

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (5) .............................................................................................................. 56

n Kodak DryView 8900 LASER IMAGER..................................................................................... 59 n Kodak DryView 8150 LASER IMAGER..................................................................................... 62 n Kodak Color Medical Imager 1000............................................................................................. 65

Page 795: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Siemens MagicView VA31B with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-Input Manager

Requirements: Siemens MagicView rel. VA31B, SHPT rel. 1.3, 8800 rel. 4.2, 8700 rel. 1.15 Note: Magicview could be linked to 8800 direct (Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31B install Camera Config.File DRY_VIEW n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 796: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Siemens MagicView VA31B with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostSPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8700 Plus

3M 8700 DryView

Requirements: Siemens MagicView rel. VA31B, 8700 Plus rel. 1.15 Note: Magicview could be linked to 8700 direct (Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31B install Camera Config.File DRY_VIEW n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8700 Plus Setup: n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Sienet, Timeout=75 n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=75

Page 797: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Siemens MagicView VA31B with Kodak DryView 8700 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8700 Standard

3M 8700 DryView

Requirements: Siemens MagicView rel. VA31B, 8700 Standard rel. 1.15 Note: Magicview could be linked to 8700 direct (Local Print) or over Camera Server Setup: on Siemens MagicView rel. VA31B install Camera Config.File DRY_VIEW

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Right n on COMM Menu:

n Siemens Default n on SIEMENS Menu:

n Modality=Sienet, Timeout=75 n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=75

Page 798: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Siemens MagicView VA31B with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8500 DualFiber Cable

3M 8700 DryView 3M8800Multi-Input Manager

Requirements: Siemens MagicView rel. VA31B, SHPT rel. 1.3, 8800 rel. 5.1, 8500 rel. 1.22 Note: Magicview could be linked to 8800 direct (Local Print) or over Camera Server Setup: n on MagicView VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 799: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Siemens MagicView VA31B with Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8500 Plus

3M 8700 DryView

Requirements: Siemens MagicView rel. VA31B, SHPT rel. 1.3, 8500 Plus rel. 1.22 Note: Magicview could be linked to 8500 direct (Local Print) or over Camera Server Setup: n on MagicView VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8500 Plus Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif=Yes n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=75

Page 800: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Siemens MagicView VA31B with Kodak DryView 8500 LASER IMAGER / Standard

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8500 Standard

3M 8700 DryView

Imager

Requirements: Siemens MagicView rel. VA31B, SHPT rel. 1.3, 8500 Standard rel. 1.22 Note: Magicview could be linked to 8500 direct (Local Print) or over Camera Server Setup: n on MagicView VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8500 Standard Setup: n on TDB/C board: Jumpers=RS422, Switch=Center n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif=Yes n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=75

Page 801: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Siemens MagicView VA31B with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual

8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

3M8800Multi-InputManager

Requirements: Siemens MagicView rel. VA31C, SHPT rel. 1.3, 8800 rel. 5.1, 8300 rel. 4.4 Note: Magicview could be linked to 8800 direct (Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31C install Camera Config.File 8300 n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n Modality Group=4

8800 Setup: n on COMM Menu: 959 Default n on IMAGE Menu: Density=16, Contrast=1 n on HOST Menu: Pixel Corr.=Yes, Scale Format=Yes, Scale Mag.=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 802: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Siemens MagicView VA31B with Kodak DryView 8300 LASER IMAGER / Standalone

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

ImagerHost

Siemens Host Protocol Translator

RS422 9-pinCopper Cable

SPCI

SPDI

Keypad

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8300

Requirements: Siemens MagicView rel. VA31C, SHPT rel. 1.3, 8300 rel. 4.4 Note: Magicview could be linked to 8300 direct (i.e., Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31C install Camera Config.File 8300 n on SHPT Service Screen set Modality=Somatom, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 8300 Setup: n on 8300 Operator Menu set:

n Density=16 n Contrast=1 n Film Layout : Format=1on 1, Mode=Portrait

n on 8300 Service Menu set: n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8,

Nbr. of Stop bits=1, Parity=Even, Protocol=3M n Digital Interface: Parity=None n Modality Group=4

Page 803: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Siemens MagicView VA31B with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual / Kodak DryView 8300 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8300 Dual

Fiber Cable

3M8800 Multi-Input Manager

3M8700DryView

8700 Dual

Fiber Cable

POEIB

9-to-9-pin Copper Cable

37-pin Digital Cable

Requirements: Siemens MagicView VA31B, SHPT 1.3, 8800 v.5.1, 8700 v.1.22, 8300 v.4.4 Note: Magicview could be linked to 8800 direct (Local Print) or over Camera Server Setup: n on MagicView VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None, Modality Group=4 8800/8700 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif.=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 804: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Siemens MagicView VA31B with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual / Kodak DryView 8500 LASER IMAGER / Dual

DEIB

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-In

putManag

er

3M 8700 DryView

8500 Dual

Fiber Cable

Requirements: Siemens MagicView VA31B, SHPT 1.3, 8800 v.5.1, 8700 v.1.22, 8500 v.1.22

Note: Magicview could be linked to 8800 direct (Local Print) or over Camera Server

Setup: n on MagicView VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9

8800/8700 Dual/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 805: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Siemens MagicView VA31B with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual / Kodak DryView 8300 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

8300 Dual

Fiber Cable

3M8800 Multi-Input Manager

3M8700DryView

8500 Dual

Fiber Cable

POEIB

9-to-9-pin Copper Cable

37-pin Digital Cable

Requirements: Siemens MagicView VA31B, SHPT 1.3, 8800 v.5.1, 8500 v.1.22, 8300 v.4.4 Note: Magicview could be linked to 8800 direct (Local Print) or over Camera Server Setup: n on MagicView VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None, Modality Group=4 8800/8500 Dual Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif.=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 806: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Siemens MagicView VA31B with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

3 M H Q L a s e r I m a g e r

Requirements: Siemens MagicView rel. VA31B, SHPT rel. 1.3, M969 HQ rel. 4.2 Note: Magicview could be linked to HQ direct (i.e., Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31B install Camera Config.File M969_HQ n on SHPT Service Screen set Modality=Sienet, Camera Type=HQ, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQ Setup: n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correction=Yes, Scale Format=Yes, Scale Magnif=Yes n on EIB Menu: Parity=Disable, Timeout=75

Page 807: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Siemens MagicView VA31B with Kodak Digital Science 969 HQT LASER IMAGER

M969 HQT

RS232 25-to-9 pinHost Adaptor Cable

SPCI

SPDI

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

3 M H Q L a s e r I m a g e r

Requirements: Siemens MagicView rel. VA31B, M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 Note: Magicview could be linked to HQT direct (Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31B install Camera Config.File M959_XL

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M969 HQT Setup: n on TDB/C board: Jumpers=RS232, Switch=Right n on COMM Menu: Siemens Default n on SIEMENS Menu: Modality=Sienet, Timeout=75 n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=TLII, Contrast=5, Density=7, on OIC Menu: Chemistry=1 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=75

Page 808: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Siemens MagicView VA31B with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

3M L a ser I m ag er

Requirements: Siemens MagicView rel. VA31B, SHPT rel. 1.3, M959 XL rel. 3.8 Note: Magicview could be linked to XL direct (i.e., Local Print) or over Camera Server Setup: n on Siemens MagicView rel. VA31B install Camera Config.File M959_XL n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n on SHPT set Density & Contrast depending on chemistry n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right n on XL Input Module install LUT TLII_959 Linear-in-Density p/n 78.8079.9817.0

Siemens RS232 25-to-9 25 pin side 2 3 7,1 18 25 Host Adaptor Cable pinout 9 pin side 4 6 1 5 9 M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Parity=Disable, Timeout=75

Page 809: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Siemens MagicView VA31B with Kodak DryView 8100 LASER IMAGER

9-to-9-pinCopper Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

DryView 8100

Imager

RS422 9-pole Plug

Requirements: Siemens MagicView rel. VA31B, SHPT v1.3, 8100 v1.1 Note: Magicview could be linked to 9410 direct (Local Print) or over Camera Server Setup: n on Siemens MagicView rel.VA31B install Camera Config.File DRY_VIEW n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=75, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=WRKSTN2A n on LOCAL PANEL Menu: Contrast=2, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Disable

Page 810: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

MagicView 1000 with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

DPCCopper Cable

DPI4-to-DPC Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

Fiber Cable

Fiber Cable

25-9 DPC-UKEIB Cable

9410 PACS Link

3M 8700 DryView

DryView 8700 Plus

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: SHPT v1.3, 9410 v1.6, 8700 v1.34 Note: Magicview could be linked to 9410 direct (Local Print) or over Camera Server Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into MagicView Camera Config.File

Setup: n on Siemens MagicView rel.VA31B install Camera Config.File DRY_VIEW n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 811: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=75, Parity=None, Memory=22 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=mv, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8700, Film Destination=Processor, Printer1=8700(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Wrkstn2a.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=2, D=14 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 812: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

MagicView 1000 via SPCI/SPDI with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

Siemens Host Protocol Translator

SPCI

SPDI

KeypadSiemens 25-pinControl Cable

Siemens 37-pinData Cable

Siemens Camera Server

DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: SHPT v1.3, 9410 v1.6, 8100 v2.4.1 Note: Magicview could be linked to 9410 direct (Local Print) or over Camera Server Setup: n on MagicView install Camera Config.File DRY_VIEW (or if problems XL) n on SHPT Service Screen set Modality=Sienet, Camera Type=XL, Timeout=75 n on UKEIB set ON/OFF/ON/OFF/OFF/ON, Switch=Right

Page 813: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=75, Parity=None, Memory=22 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=mv, Hosp=siemens, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8100, Film Destination=Processor, Printer1=8100(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Wrkstn2a.w87, Multi-Printer Response=Off, Autoswitching=Off n Mem.Full Response=On, Image Size Mode=On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=2, D=14 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 814: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

MagicView 1000 via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensCameraServer

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: Magicview could be linked to MIM200 direct (Local Print) or over Camera Server MagicView Setup: on MagicView VA31B install Camera Config.File XLP MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=MagicView Wkst.: n Board/Channel=Digital Board 1 Channel 1, Logical Name=mv, n Mod.Name=mv, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=64, Lines=64, Parity=None, Timer=59, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On

Page 815: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=0.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 816: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

MagicView 1000 via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensCameraServer

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: Magicview could be linked to MIM200 direct (Local Print) or over Camera Server MagicView Setup: on MagicView VA31B install Camera Config.File Kodak 2180 MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=MagicView Wkst.: n Board/Channel=Digital Board 1 Channel 1, Logical Name=mv, n Mod.Name=mv, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=64, Lines=64, Parity=None, Timer=59, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On

Page 817: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=0.0, Auto Study=Off, Console=On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 818: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

MagicView 1000 via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

SiemensCameraServer

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: Magicview could be linked to MIM200 direct (Local Print) or over Camera Server MagicView Setup: on MagicView VA31B install Camera Config.File Kodak 1120 MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config,, Input, Direct Connect, Config.Add, Digital, Qual.=MagicView Wkst.: n Board/Channel=Digital Board 1 Channel 1, Logical Name=mv, n Mod.Name=mv, Primary Control: Type=Siemens SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=64, Lines=64, Parity=None, Timer=59, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n 2400, RS422, 7, 2, Odd

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On

Page 819: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=0.0, Auto Study=Off, Console=On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 820: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

MagicView 1000 via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SiemensCameraServer

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

25-to-25 NullModem Cable

Fiber Cable

3M 8700 DryView

Kodak DryView 8700 Plus

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM 200 Destinations and if HQ by installing HQ into Siemens Camera Config.File

MagicView Setup: on MagicView VA31B install Camera Config.File DRY_VIEW MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=MagicView Wkst:

n Board/Channel=Digital Board 1 Channel 1, Logical Name=mv, n Mod.Name=mv, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=64, Lines=64, Parity=None, Timer=59, Sync=Off, Pixel=8

n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=0, Interpolation Smooth=0

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Page 821: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=0, Film Contrast=2 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Wrkstn2a.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 822: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

MagicView 1000 via SPCI/SPDI with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

RS23-to-RS42225-to-15 pinConverter Box

Siemens 25-pinControl Cable

Siemens 37-pinData Cable

Kodak MIM 200

SPCI

SPDI

RS422 37-to-50 pinDigital Adaptor Cable

25cm=10inch Extension(not mandatory) Cable +Kpad / Host Control Octopus Adaptor Cable25-to-25 Null

Modem Cable COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

Kodak DryView 8100

RS4229-pole Plug

SiemensCameraServer

Requirements: Siemens MagicView 1000 rel. VA31B Requirements: MIM200 v6.1, 8100 v2.4.1 MagicView Setup: on MagicView VA31B install Camera Config.File DRY_VIEW MIM200 Setup: n inside the 232-to-422 25-to-15-pin Converter Box set S1.1=ON, S1.2=ON

i.e., delivering +12V in case of Hirschmann converter on Siemens Control Cable n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config, Input, Direct Connect, Config.Add, Digital, Qual.=MagicView Wkst: n Board/Channel=Digital Board 1 Channel 1, Logical Name=mv, n Mod.Name=mv, Primary Control: Type=3M - SPCI, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=64, Lines=64, Parity=None, Timer=59, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4, 2400, RS422, 7, 2, Odd, Ack Wait Timer=2, Start Timer=1 n Interpolation Sharp=0, Interpolation Smooth=0 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Page 823: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination=8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=0, Film Contrast=2 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=Wrkstn2a.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 824: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Siemens Magicview via DICOM with Kodak DryView 8300 LASER IMAGER

Siemens Magicview

DryView 8300

DICOM Network

Requirements: Siemens Magicview rel. VA32 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: Image Data lutted by MagicView, linear-in-Density LUT into Camera MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8300 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8300_Dicom, - DICOM services=PRINT_SCP, aet=8300, port=104, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed e.g., 1=kodakd 3M_DryView_8300_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16 n Contrast=1 n Sharp/Smooth=1 n Film Layout : Format=1 on 1, Mode=Portrait

n on 8300 Service Menu into Configure User set: n Modality Group=4 (i.e., LUT=linear-in-Density)

Page 825: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

Siemens MagicView VA32 via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Siemens MagicView

DICOM Network

Kodak 190 camera

Requirements: Siemens MagicView rel. VA32, 190 rel. 1.7.29 MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=K190 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_190_Dicom, - DICOM services=PRINT_SCP, aet=190, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed e.g., 1=kodakd Kodak_190_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=0.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 826: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

MagicView 1000 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens MagicView

8700 Plus

9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siemens MagicView 1000 rel. VB32, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 and HQ by installing 8500 and HQ into MagicView DICOM Camera Config.File

MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8700 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8700_Dicom, - DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_DryView_8700_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 827: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=Superset n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=SCU_DBP, SCU IPAddr=accordingly, SCP=8700 n SCP=8700, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 828: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

MagicView 1000 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Siemens MagicView

DryView 81009410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siemens MagicView 1000 rel. VB32, 9410 v1.6, 8100 v2.4.1 MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8100 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8100_Dicom, - DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_DryView_8100_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 829: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=2, TFT/ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 830: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

MagicView 1000 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Siemens MagicView 1000

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8300 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8300_Dicom, - DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_DryView_8300_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 831: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=MERGE_PRINT_SCU, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=1, TFT/ULUT=wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 832: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

MagicView 1000 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Siemens MagicView 1000

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siemens MagicView 1000 rel.VB33, 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by MagicView, linear-in-Density LUT into Camera MagicView Setup (using 8600 Config.File): - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8610 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8600_Dicom, - DICOM services=PRINT_SCP, aet=9410, port=1024, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of printer to be installed eg 1=kodakd Kodak_DryView_8600_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView To verify True Size on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Segment Type=anatomical, Scale=ON To eliminate white bands on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Background R=0, G=0, B=0

Page 833: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

9410 Setup: n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations=5 n on SCP PRINTER Menu, Registered User: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=6 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma Table=Linear OD, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 834: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Siemens MagicView

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak 160 camera

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: MIM200 v6.1, KELI 160 v6.1 MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=K160 Dicom Printer, - modality type=DICOM_PRINTER, - camera type=Kodak_KELI_160_Dicom (or Kodak_MLP_190_Dicom), - DICOM services=PRINT_SCP, aet=160, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd Kodak_KELI_160_Dicom

(or 1=kodakd Kodak_MLP_190_Dicom ) - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 835: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 836: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Siemens MagicView 1000

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200 Requirements: Siemens MagicView 1000 rel. VB32 Requirements: MIM200 v6.1, 2180 v2.17H MagicView Setup: - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=K2180 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_2180_Dicom, - DICOM services=PRINT_SCP, aet=2180, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd Kodak_2180_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 837: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 838: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Siemens MagicView 1000

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200 Requirements: Siemens MagicView 1000 rel. VB32 Requirements: MIM200 v6.1, 1120 v2.40/032 Note: due to a swap of the columns with rows the film size 11x14 is not working MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=K1120 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_1120_Dicom, - DICOM services=PRINT_SCP, aet=1120, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd Kodak_1120_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 839: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=No Magnif n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 840: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Siemens workstationMagicView 1000

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Requirements: Siemens MagicView 1000 rel. VB32B Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=K8200 Dicom Printer, - modality type=DICOM_PRINTER, - camera type=Kodak_DryView_8200_Dicom (or Kodak_MLP_190_Dicom), - DICOM services=PRINT_SCP, aet=8200, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of printer to be installed eg 1=kodakd Kodak_DryView_8200_Dicom

(or 1=kodakd Kodak_MLP_190_Dicom ) - exit/exit (i.e., in order to return to main menu) and reboot MagicView MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 841: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 842: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Siemens workstationMagicView 1000

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 and HQ by installing 8500 and HQ into MagicView Camera Config.File

MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8700 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8700_Dicom, - DICOM services=PRINT_SCP, aet=8700, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_DryView_8700_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView

Page 843: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 844: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Siemens workstationMagicView 1000

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8100 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8100_Dicom, - DICOM services=PRINT_SCP, aet=8100, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of printer to be installed eg 1=kodakd Kodak_DryView_8100_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 845: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Wrkstn2a.w87 (Always=Y), Contrast (dry)=1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=0 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 846: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Siemens workstationMagicView 1000

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (i.e., to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8300 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8300_Dicom, - DICOM services=PRINT_SCP, aet=8300, port=5040, IPaddr=accordingly - RETURN, exit, exit (i.e., in order to return to main menu) - from main menu do: install/net - exit (i.e., in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (i.e., to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_DryView_8300_Dicom - exit/exit (i.e., in order to return to main menu) and reboot MagicView MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 847: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=wkstn83a.w8u (Always=Y), Contrast (dry)=1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 848: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 56

MagicView 1000 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: MagicView 1000 rel.VB33 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: Image Data lutted by MagicView, linear-in-Density LUT into Camera MagicView Setup (using 8600 Config.File): - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8610 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8600_Dicom, - DICOM services=PRINT_SCP, aet=8610, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter number of printer to be installed eg 1=kodakd Kodak_DryView_8600_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView To verify True Size on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Segment Type=anatomical, Scale=ON To eliminate white bands on the printed film, set on MagicView: - select the Print icon and into menu Setup/Layout under Segment Settings set:

Background R=0, G=0, B=0 MagicView Setup to print images with Dmax=350: - into Service Login (at Unix level),

edit density.dat file and set 350 Dmax value for digital-mammo images ie

Siemens Mammomat 3000 NovaMagicView 1000 platformReview Console

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 849: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 57

cd /home/cs_root/data/lut vi density.dat change the following 6 lines as follows:

0 DX 350 0 CR 350 0 MG 350 0 CT 350 (this line needed when Ref.Test Patterns eg SMPTE are used) 0 OT 350 0 DEFAULT 350

reboot MagicView MagicView Setup to print with Image Data lutted by MV, not lutted by 8610 (setup: Gamma=Lin.in Density, C=6, Modality Group=1): - into Service Login (at Unix level),

edit LUT^CR.def file and modify it with following exp / density value pairs ie cd /home/cs_root/data/lut vi LUT^CR.def change the lines as follows: 0 20 25 31 51 42 76 56 102 73 127 93 153 115 178 143 204 182 229 230 255 300 copy LUT^CR.def file into the LUT^CT.def, LUT^MG.def and LUT^DX.def files (ie LUT^CR.def is the file with LUT applied by MV to image data and is copied into LUT^CT.def, LUT^MG.def and LUT^DX.def to be sure to have same LUT applied by MV to image data no matter which Modality-tag have the image data) ie cd /home/cs_root/data/lut cp LUT^CR.def LUT^CT.def (needed when Ref. Test Patterns eg SMPTE used) cp LUT^CR.def LUT^MG.def cp LUT^CR.def LUT^DX.def reboot MagicView

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

Page 850: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 58

n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600),Header/Line,Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=6 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=nova n Print Priority=Normal (Always=N), Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 851: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 59

MagicView 1000 via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) MV Setup (using Kodak 8200 or 3M M969 HQ Config.file, easier config.): - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8900 Dicom Printer, - modality type=DICOM_PRINTER, camera type= Kodak_DryView_8200_Dicom, - DICOM services=PRINT_SCP, aet=8900, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter nbr of the printer to be installed eg 1=kodakd Kodak_DryView_8200_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView MagicView Setup (creating 8900 by modifying files, only if True Size needed): - into Service Login (at Unix level) in /home/cs_root/data/camera directory

dbp_format.dat and dbp_camera_types.dat files needs to be edited by adding the DV8900 matrixes ie cd /home/cs_root/data/camera vi dbp_format.dat add the following lines:

Kodak_DryView_8900_Dicom 14x17 350.75x427.03 4488x5464 325 Kodak_DryView_8900_Dicom 14x14 350.75x350.75 4488x4488 325 Kodak_DryView_8900_Dicom 11x14 274.63x350.75 3514x4488 325 Kodak_DryView_8900_Dicom 10x12 248.84x299.17 3184x3828 325 Kodak_DryView_8900_Dicom 8x10 197.57x248.84 2528x3184 325

cd /home/cs_root/data/camera vi dbp_camera_types.dat

SiemensMagicView 1000workstation

DICOM Network

Kodak DryView 8900

Page 852: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 60

add the following line: Kodak_DryView_8900_Dicom - reboot MagicView - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8900 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8900_Dicom, - DICOM services=PRINT_SCP, aet=8900, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter number of the printer to be installed eg 1=kodakd Kodak_DryView_8900_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView - at this point only a default-Layout ie printing format is available for 8900 - other Layouts ie other printing formats could be manually genarated

by using the Layout-Editor which is present inside MagicView application - otherwise other Layouts ie other printing formats could be automatically

generated deriving them from the Layouts of an already existing camera - to automatic generate other Layouts ie other printing formats

from main menu do: hc_install/modify/copy layouts input=Kodak_KELP_2180_Dicom output=Kodak_DryView_8900_Dicom

- reboot MagicView 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0

Page 853: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 61

n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Wrkstn2a.w87 (Always=Y), Contrast=2 (Always=Y) n Smoothing Type=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mv

Page 854: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 62

MagicView 1000 via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) MV Setup (using Kodak 8200 or 3M M969 HQ Config.file, easier config.): - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8150 Dicom Printer, - modality type=DICOM_PRINTER, camera type= Kodak_DryView_8200_Dicom, - DICOM services=PRINT_SCP, aet=DV8150, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter nbr of the printer to be installed eg 1=kodakd Kodak_DryView_8200_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView MagicView Setup (creating 8150 by modifying files, only if True Size needed): - into Service Login (at Unix level) in /home/cs_root/data/camera directory

dbp_format.dat and dbp_camera_types.dat files needs to be edited by adding the DV8150 matrixes ie cd /home/cs_root/data/camera vi dbp_format.dat add the following lines:

Kodak_DryView_8150_Dicom 14x17 346.70x421.07 4438x5390 325 Kodak_DryView_8150_Dicom 14x14 346.70x344.82 4438x4414 325 Kodak_DryView_8150_Dicom 11x14 268.73x346.70 3440x4438 325

cd /home/cs_root/data/camera vi dbp_camera_types.dat add the following line:

Kodak_DryView_8150_Dicom

SiemensMagicView 1000workstation

DICOM Network

Kodak DryView 8150

Page 855: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 63

- reboot MagicView - into Service Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=DV8150 Dicom Printer, - modality type=DICOM_PRINTER, camera type=Kodak_DryView_8150_Dicom, - DICOM services=PRINT_SCP, aet=DV8150, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter numbr of the printer to be installed eg 1=kodakd Kodak_DryView_8150_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView - at this point only a default-Layout ie printing format is available for 8150 - other Layouts ie other printing formats could be manually genarated

by using the Layout-Editor which is present inside MagicView application - otherwise other Layouts ie other printing formats could be automatically

generated deriving them from the Layouts of an already existing camera - to automatic generate other Layouts ie other printing formats

from main menu do: hc_install/modify/copy layouts input=Kodak_KELP_2180_Dicom output=Kodak_DryView_8150_Dicom

- reboot MagicView 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify:

Page 856: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 64

n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Wrkstn2a.w87 (Always=Y) n Contrast=1 (Always=Y), Smoothing Type=0 (Always=Y) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mv

Page 857: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 65

MagicView 1000 via DICOM with Kodak Color Medical Imager 1000

Requirements: Siemens MagicView 1000 rel. VB32 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) MagicView Setup: - into Sevice Login (at Unix level), logged as sit install from main menu do: - edit/config/create (ie to configure the DICOM printer as separate node) - node name=kodakd (max 6 chars), component name=CMI1000 Dicom Printer, - modality type=DICOM_PRINTER, camera type=3M_DryView_8300_Dicom, - DICOM services=PRINT_SCP, aet=CMI1000, port=5040, IPaddr=accordingly - RETURN, exit, exit (ie in order to return to main menu) - from main menu do: install/net - exit (ie in order to return to main menu) and reboot MagicView - from main menu do: hc_install/install devices/install (ie to select the printer) - enter number of the printer to be installed eg 1=kodakd 3M_DryView_8300_Dicom - exit/exit (ie in order to return to main menu) and reboot MagicView CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=7 (Always=Y) n TFT Set (From list)=Wrkstn2a.w87 (Always=Y)

DICOM Network

Kodak CMI 1000

SiemensMagicView 1000workstation

Page 858: Siemens Setup Manuals

Siemens workstation MagicView 1000 with LASER IMAGER Products

Author: [email protected], Edition: May ´05 66

n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=N), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit