TRANSFORMER
75kVA 480Δ
208Y/120V 3ɸ4W
SPD
PNL H1B
100A3P
480/277V
PROVIDE CEILING CORD
DROP RECEPTACLES ABOVE
TABLES AND WHERE
REQUIRED
WAP
WAP
WAP
WAP
WAPWAP
UP
WAP
WAP
PNL L1C
250A3P
208/120V
WAP
E
D
F
T
ESP-1
FSD-1
EWC-1
KN-1
KN-1C
UP TO LIGHT AT
TOP OF SHAFT
L1C-11
L1C-11 L1C-11
L1C-11
L1C-11 L1C-11
L1C-11
L1C-13 L1C-13
L1C-13
L1C-13
L1C-13
L1C-13L1C-13
L1C-14
L1C-14
L1C-14 L1C-14
L1C-14
L1C-14
L1C-15 L1C-15
L1C-15
L1C-15
L1C-15
L1C-16
L1C-16
L1C-16
L1C-16
L1C-16
L1C-16
L1C-16
L1C-17
L1C-17
L1C-17
L1C-17
L1C-18
L1C-18
L1C-18
L1C-18
L1C-18
L1C-19 L1C-19
L1C-19
L1C-19
L1C-19
L1C-20
L1C-20
L1C-20
L1C-20
L1C-21
L1C-21
L1C-21
L1C-21
L1C-22
L1C-22
L1C-22
L1C-22
L1C-22
L1C-22
L1C-23
L1C-23
L1C-23
L1C-23
L1C-24
L1C-24
L1C-24
L1C-24
L1C-24
L1C-25
L1C-25
L1C-25
L1C-25
L1C-26
L1C-25
L1C-26
L1C-26
L1C-27
L1C-27
L1C-39
L1C-24
L1C-26
L1C-19L1C-21
L1C-41L1C-41
L1C-41
L1C-42 L1C-42
L1C-42
L1C-43
L1C-43
L1C-68
L1C-43
L1C-43
L1C-44
L1C-45
L1C-46
L1C-47
L1C-47
L1C-47
L1C-47
L1C-47
L1C-47
L1C-48
L1C-48
L1C-48
L1C-48
L1C-50
L1C-50
L1C-50
L1C-50
L1C-50
L1C-51
L1C-51
L1C-51
L1C-52
L1C-52
L1C-52
L1C-54
L1C-54
L1C-56
L1C-56
L1C-53
L1C-53
L1C-53
L1C-53
L1C-55
L1C-55
L1C-55
L1C-55
L1C-57
L1C-57
L1C-58
L1C-60
L1C-59
L1C-59
L1C-61
L1C-63
L1C-43
L1C-41
L1C-41
POWERED PROJECTION
SCREEN WITH RAISE/LOWER
CONTROL SWITCH BY
MANUFACTURER, WIRING
PER MANUFACTURER
INSTALLATION LITERATURE,
INSTALLATION BY DIV 26
L1C-53
TF-1
CUH-5
L1C-72
L1C-74L1C-70
FLEXCLASSROOM
113
CLASSROOM126
BOY'S112
CLASSROOM127
CLASSROOM128
CLASSROOM129
KINDERGARTEN130
KINDERGARTEN131
KINDERGARTEN132
KINDERGARTEN133
COMMONS134
ART108
STAFF RR124
STORAGE130B
RR130A
STORAGE131B
RR131A
STORAGE132B
RR132A
STORAGE133A
GIRL'S110
CUST.111
KILN108A
STORAGE108B
ELEC.125A
VESTIBULE109A
STORAGE106C
RESOURCEROOM
125
CORRIDOR103
OFFICE109B
STAIR 2S2.1
VESTIBULE114
STAIR 1S1.1
LIBRARYMEDIA
CENTER109
VESTIBULE106D
IDF125B
BREAKOUT103D
BREAKOUT103C
RR133B
L1C-47
L1C-39
L1C-41
L1C-81
TO POWER SHADE
CONTROLLERS
(TYPICAL OF 4)
L1C-78
L1C-80
L1C-77
L1C-79
L1C-76
L1C-81
LINE VOLTAGE
TSTAT FOR
EF9
LINE VOLTAGE
SWITCH FOR
EF10
GROUND
BUS
L2C-47
(PART)
SHADE
CONTROLLER
ABOVE CEILING
TO FIRST FLOOR
SWITCH
F1
WAP
MA
TC
H L
IN
E A
RE
A B
MA
TC
H L
IN
E A
RE
A A
1 2 3 4
65
6.5
G
K
L
J
M
H
ALL FLAG NOTES MAY NOT BE USED ON THIS SHEET
TEACHING WALL - TEACHERS WORK STATION WITH
4-PLEX RECEPTACLE AND VOICE/DATA/VIDEO OUTLET
MOUNTED AT +18" AFF . PROVIDE (1) DATA , (1) VOICE AS
NOTED AS WELL AS, (1) HDMI AND (1) VGA CABLE
BETWEEN TEACHERS WORK STATION AND PROJECTOR.
TEACHING WALL - PROJECTOR LOCATION WITH DUPLEX
RECEPTACLE AND DATA/VIDEO OUTLET MOUNTED AT
+86" AFF, CENTERED ABOVE PROJECTION WHITE BOARD,
COORDINATE EXACT PLACEMENT WITH PROJECTOR
MOUNTING BRACKET. PROVIDE (1) DATA CABLE AS
SPECIFIED AS WELL AS (1) HDMI AND (1) VGA CABLE
BETWEEN TEACHERS WORK STATION AND PROJECTOR.
PROVIDE GFCI PROTECTION DEVICE AT +84" AFF FOR
VENDING MACHINE WITH VENDING MACHINE
RECEPTACLE BELOW AT +18" AFF CONNECTED TO GFCI
PROTECTED OUTPUT LEADS.
NOT USED
PROVIDE RECESSED TV POWER AND COMMUNICATIONS
DEVICE CONNECTION BOX, MOUNTED AT ELEVATION
SHOWN ON PLAN WITH PASS AND SEYMOUR RECESSED
TV BOX, TV3W SERIES.
NOT USED
PROVIDE POKE THROUGH TYPE FLOOR OUTLET BOXES IN
LMC. CONDUIT SCORRIDOR BE INSTALLED UNDER
FLOOR WITHIN CRAWL SPACE. PROVIDE WIREMOLD
LEGRAND 6AT SERIES DEVICE
PROVIDE A DISCONNECT FOR THE KILN AND A
RECEPTACLE INTERLOCKED WITH THE DISCONNECT FOR
THE ENVIROVENT ALSO INTERLOCK THE KILN POWER
WITH THE ROOM EXHAUST FAN. REFERENCE THE
MECHANICAL EQUIPMENT ELECTRICAL CONNECTION
SCHEDULE ON SHEET E-413, THE KILN ELECTRICAL
WIRING DETAIL ON SHEET E-501, AND THE KILN
INTERLOCK CONTROL DIAGRAM ON SHEET E-500.
BASE BID: PROVIDE NEW POWER AND VOICE/DATA
DEVICES AS INDICATED MOUNTED IN FIXED WALL.
ALTERNATE A1: ELIMINATE AND/OR RELOCATE POWER
AND VOICE/DATA DEVICES AS NOTED
FLAG NOTES:
TELECOM DEVICES SHOWN ON THIS SHEET FOR
RECEPTACLE RELATIONSHIP WITH LOCATIONS ONLY.
REFER TO SPECIAL SYSTEMS DRAWINGS E-131A, E-131B,
E-131C, E132B, AND E132C FOR INSTALLATION
REQUIREMENTS
JJ
08.04.2016160025
PERMIT SET
DJA
REVISION DATE
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATIONAPPEARING HEREIN SHALL NOT BE
DUPLICATED, DISCLOSED OR OTHERWISEUSED WITHOUT THE WRITTEN CONSENT OF
MOA ARCHITECTURE
Cons
ultan
t Log
o
AD
DIT
IO
NS
A
ND
R
EN
OV
AT
IO
NS
SIE
RR
A E
LE
ME
NT
AR
Y S
CH
OO
L
7771
Oak
St.
Arva
da, C
O 80
005
E-111B
LEVEL 1POWER PLAN
AREA "B"
1/8" = 1'-0"
EXISTINGBUILDING
AREA 'B'
AREA 'C'
AREA 'A'
AD#1AD
08/12/2016ADDENDUM #1
+96"
PR21
+96"
PR21
5
+54"
L1C57
PR21
PR-21 03-16-2017PR21
J
AUDIO
ENHANCEMENT
L1C85
CLNG
J
AUDIO
ENHANCEMENT
L1C85
CLNG
J
AUDIO
ENHANCEMENT
L1C85
CLNG
PR21
PR21
J
AUDIO
ENHANCEMENT
L1C87
CLNG
J
AUDIO
ENHANCEMENT
L1C87
CLNG
J
AUDIO
ENHANCEMENT
L1C87
CLNG
J
AUDIO
ENHANCEMENT
L1C87
CLNG
J
AUDIO
ENHANCEMENT
L1C87
CLNG
PR21
PR21
PR21
PR21PR
21
J
AUDIO
ENHANCEMENT
L1C87
CLNG
REF: RFI 0079
LMC Floor Box Layout
REF: RFI 0084
Ceiling Cord Drop Receptacle
Locations & Length of Cord
REF: RFI 0174
Provide JBox in crawl space below
and route 1/2" flex conduit vertically
up through the wall cavity to device
at each device location. Based on
thewall finish Shop Drawings there
will be a void between the blocking of
approximately 11/2"
REF: RFI 0192
Receptacle ReLocation
REF: RFI 0224TCTP Circuits & J-Boxes (Eliminated)
RFI 0237
REF: PR_023
Convert the wiremold 6AT poke thru at this location to a power and
data furniture device. Route 3/4" flex conduit for each power and
data from floor box to the first device under the desk as well as
from device to device. Provide (3) new CAT6 cables, (1) for each
data outlet. Refer to circ. desk detail for locations.
PR33
PR33
PR33
PR33PR
33
PR33
PR33
PR33
PR33
PR33
PR 041 - AddedReceptacle in LMC
GENERAL NOTES REFER TO THE ARCHITECTURAL PLANS FOR ADDITIONAL INSTALLATION REQUIREMENTS.
ALL DEVICES BOLD DEVICES ARE NEW UNLESS OTHERWISE NOTED. RL – INDICATES EXISTING DEVICE TO BE RELOCATED TO
POSITION SHOWN. R - INDICATES EXISTING DEVICE TO BE REPLACED E - INDICATES EXISTING DEVICE TO REMAIN AS IS AC – INDICATES ABOVE COUNTER, COORDINATE EXACT HEIGHT BC – INDICATES BELOW COUNTER, COORDINATE EXACT HEIGHT
CIRCUITING ROUTING SHOWN IS DIAGRAMMATIC. CIRCUIT HOMERUN DESIGNATIONS ARE INDICATED AND SHALL BE STRICTLY FOLLOWED. ALL CIRCUITING SHALL BE COPPER CONDUCTORS IN CONDUIT (3/4" MINIMUM). CONTRACTOR SHALL PROVIDE ALL WIRE, CONDUIT, JUNCTION/PULL BOXES, AND SUPPORTS ETC. FOR A COMPLETE ELECTRICAL SYSTEM.
ROUTE ALL CONDUIT/CIRCUITING IN FINISHED SPACES CONCEALED IN WALLS, ABOVE CEILINGS, OR BELOW FLOORS. ALL CONDUIT/CIRCUITING SHALL BE RUN PARALLEL TO BUILDING WALLS/LINES.
ALL WIRING SHALL BE IN COMPLIANCE WITH THE NEC 2014 EDITION: ALL MULTI-CIRCUIT BRANCH WIRING (120V SINGLE PHASE CIRCUITS) INSTALLED WITH A COMMON NEUTRAL AND IDENTIFIED IN THE PANEL SCHEDULES ORIGINATING FROM SINGLE POLE BREAKER SHALL BE INSTALLED WITH BREAKER HANDLE TIES, MULTI-POLE BREAKERS, OR A DEDICATED NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR. THE NEUTRAL CONDUCTOR SHALL HAVE A TRACER STRIPE (THE STRIPE COLOR SHALL MATCH THE COLOR OF THE PHASE CONDUCTOR).
ALL OFFICE RECEPTACLE CIRCUITS SHALL BE PROVIDED WITH A SEPARATE DEDICATED NEUTRAL CONDUCTOR. ALL CIRCUITING SHALL BE PROVIDED WITH AN INSULATED, GREEN GROUND WIRE.
ALL NEW RECEPTACLES SHALL BE TAMPERPROOF, CHILD GUARD TYPE THROUGHOUT THE SCHOOL.
MOUNTING HEIGHTS ARE AS FOLLOWS UNLESS NOTED OTHERWISE OR A PREVIOUS BUILDING STANDARD HAS BEEN ESTABLISHED.
POWER RECEPTACLES +18” TELEPHONE AND DATA OUTLETS +18”
ALL DIMENSIONS ARE TO THE CENTER OF THE DEVICE.
NEW TELEPHONE, DATA, AND TELE/DATA COMBINATION OUTLETS SHALL CONSIST OF A 4" SQUARE BACK BOX, SINGLE GANG PLASTER RING, AND 3/4" CONDUIT TO ABOVE THE CEILING. PROVIDE A RUBBER CABLE PROTECTION BUSHING ON THE END OF THE CONDUIT STUBBED OUT ABOVE THE CEILING.
COORDINATE EXACT POWER AND INSTALLATION REQUIREMENTS OF MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR AND THE MANUFACTURER'S INSTALLATION LITERATURE.
CONTRACTOR SHALL EXAMINE ALL EXISTING DEVICES THAT ARE INDICATED TO REMAIN OR BE RELOCATED (RECEPTS, SWITCHES, DIMMERS ETC.) AND REPLACE DAMAGED UNITS WITH NEW.
CONTRACTOR SHALL PROVIDE ADDITIONAL SUPPORTS FOR ALL EXISTING EQUIPMENT, CONDUIT (RIGID AND FLEX), AS WELL AS CABLE LOCATED ABOVE THE CEILING. SUPPORT FROMSTRUCTURE AS REQUIRED BY NEC. FOR PANELS WITH CIRCUITS INDICATED HEREON TO BE MODIFIED, PROVIDE AN UPDATED TYPED PANEL DIRECTORY IN EACH IMPACTED PANEL. INCLUDE CONTRACTOR’S CONTACT INFORMATION AND CLOSE-OUT DATE OF THE PROJECT.
REF: RFI 0079LMC Floor Box Layout
REF: RFI 0084Ceiling Cord Drop ReceptacleLocations & Length of Cord