siprotec 5siprotec 5 - siemens · siprotec 5: holistic workflow with siprotec 5, you are almost...
TRANSCRIPT
SIPROTEC 5SIPROTEC 5
© Siemens AG 2013. All rights reserved.
Siemens Protection Portfoliofor all areas of application
GenerationSIPROTEC 4
TransmissionSIPROTEC 4
SIPROTEC 5
DistributionSIPROTEC 4SIPROTEC
IndustrySIPROTEC 4SIPROTEC
SIPROTEC 5 CompactReyrolle
SIPROTEC Easy
CompactReyrolle
SIPROTEC Easy
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 2 Smart Grid Division
SIPROTEC: Highest-measured MTBF
Siemens SIPROTEC Reliability Other vendors: 1 failure / year every 100-300 units *Siemens SIPROTEC: 1 failure / year every 600 units in averagey y g
* Others may not include initial product failures
Measured MTBF (years) for SIPROTEC Family
1,200.00
1,400.00
800.00
1,000.00
,
7SD6 Differential7SA5 Distance
400.00
600.00
7SA5 Distance7UT5 Transformer7SJ6 Feeder
0.00
200.00
2004 2005 2006 2007 2008 2009 2010
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 3 Smart Grid Division
2004 2005 2006 2007 2008 2009 2010
SIPROTEC: Highest Relay Software Stability
14
16# of Upgrades per Year
Frequent updates89 upgrades in 8 years
10
12
6
8
10
USA MarketSIEMENS
2
4
6
0
2
2005 2006 2007 2008 2009 2010 2011 2012
Very Stable8 upgrades in 8 years
When software is stable, only addition of features cause new releases (1/year).
Frequent firmware updates cause serious time consumption and additional cost in maintenance besides reliability concerns
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 4 Smart Grid Division
Frequent firmware updates cause serious time consumption and additional cost in maintenance, besides reliability concerns.
SIPROTEC 5: Innovation Highlights
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 5 Smart Grid Division
SIPROTEC 5: Perfect Tailored Fit
Base Modules Front Panels / HMI Expansion Modules Communication Modules
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 6 Smart Grid Division
SIPROTEC 5: Perfect Tailored Fit
Base Module Expansion Modules Up to19'' rack
+ =+ + +
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 7 Smart Grid Division
Mounting of an Expansion Module
Robust and stable connection between
partsparts
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 8 Smart Grid Division
SIPROTEC 5: Front Panel (HMI)
Description Fieldfor LEDs 16 LEDs (red)
Base Module Expansion Module
16 LEDs (red)
Description Fieldfor LEDs
Context Sensitive Keys
for LEDs16 LEDs (green or red, selectable)
LED Acknowledgeand Reset of latched
information Cursor Keys
Numerical Keysand Function Keys
Key Switch S5 “Remote/Local”
Control of Switching ElementsUSB plug-in
Description Field
Key Switch S1 “Interlocking Off / Normal”
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 9 Smart Grid Division
gfor Function Keys
SIPROTEC 5: Designed to Communicate
Ethernet moduleElectrical and Optical modules without / with integrated switch
Universal SerialElectrical and Optical modules
Up to 8 communication portsin one device
without / with integrated switch p
Electrical module with RS485 interfaceElectrical Ethernet module
with two electrical ports
Optical long distance module with two 1300 or 1550 nm interfacesOptical Ethernet module with
two optical ports
Fiber optical module withEN
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 10 Smart Grid Division
Fiber optical module with820 nm interface
* Wave division multiplexer
EFP
SIPROTEC 5: Holistic Workflow
With SIPROTEC 5, you are almost finished right at the beginning Primary and Secondary Equipment
Application templates in DIGSI 5
finished right at the beginning Graphically Linked
Application templates in DIGSI 5 (i.e., line protection)
Select the application template, which defines the complete functional scope
Customize application as required to individual requirementsindividual requirements
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 11 Smart Grid Division
SIPROTEC 5: Innovative Terminal Technology
Terminal Blocks are Removable (Pre Wire your
Excellent for retrofitting or maintenance
Terminal Blocks are Removable (Pre Wire your Retro Fit Projects)
CT’s Integrated in the Blocks
CT’s Auto Short for Safety!
No Bare Copper or Metallic Surface pp
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 12 Smart Grid Division
SIPROTEC 5: Security and Safety Inside
Beyond NERC CIP Cyber-security ComplianceMulti-level Cyber-security Chain
Encryption of the communication line between DIGSI 5 and the SIPROTEC 5 relay
Connection password according to NERC-CIP requirements
R di f tt tRecording of access attempts in a non-volatile safety log
Safety-critical operations require the input of confirmation codes
Sophisticated self-monitoring routines locate and report device disturbances immediately and accurately q pand accurately
Proven functions for the protection of equipment and users were continually enhanced over 5 generations
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 13 Smart Grid Division
SIPROTEC 5: 1 ½ Breaker Application
MP U 3p
BB I 230kV
MP I 3p
MP I 3p 7Sx8
A_Q0
A Q9
7SL87P1C5036
MP U 1p
MP U 3p
MP U 3p
MP I 3p 7Sx8
r-B
us
A_Q9
MP U 1p
MP I 3p
MP I 3p
MP I 3p 6MD8 iam
eterB_Q0
C_Q9
6MD86P1G4312
MP U 3p
Di
I/O Unitfor Additonal Indications7SL87 6MD85
MP I 3p
MP I 3p 7Sx8
C_Q0
6MD8
(i.e. MCB Trips etc.)7SL87
P1C50366MD85P1G499
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 14 Smart Grid Division
BB II 230kV
SIPROTEC SoftwareSIGRA – The Standard for Fault Analysis
SOESOEAnnunciation
MeasurementsOscillography
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 15 Smart Grid Division
Wide Area Grid Monitoring – SIGUARD
Infrastructure & Cities Sector – Smart Grid Division © Siemens AG 2013. All rights reserved.Page 16 Smart Grid Division