  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    1/18

    Energy Sector

    Copyright Siemens AG 2011. All rights reserved.Energy Sector

    Energy AutomationSIPROTEC 5

    Line Protection Devices

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    2/18

    Energy Sector

    Siemens AG 2011

    Energy AutomationPage 2 V 1.0

    Understanding the line protection product portfolio

    Major ordering features

    New applications and new functions

    Scope of functions and application templates

    What you will learn

    Training objective

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    3/18

    Energy Sector

    Siemens AG 2011

    Energy AutomationPage 3 V 1.0

    Content

    Content

    Product portfolio

    New applications and functions

    Scope of functions and

    application templates

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    4/18

    Energy Sector

    Siemens AG 2011

    Energy AutomationPage 4 V 1.0

    Siprotec 5 Line ProtectionProduct portfolio according marked segments

    Transmission with 1/3pole tripping (7SA87/ 7SD87/ 7SL87/7VK87)

    tripping time < 1 cycle

    HW with expandable CTs, VTs (e.g. 1,5 CB application) and binary I/Os

    required

    Transmission, Subtransmission and Distribution with 3-pole tripping

    7SA86/ 7SD86/ 7SL86

    Tripping time < 1 cycle

    HW with expandable CTs, VTs (e.g. 1,5 CB application) and binary I/Os

    required

    7SA84/ 7SD84

    Tripping time > 1,25 cycles

    Fixed amount of analogue and binary I/Os

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    5/18

    Energy Sector

    Siemens AG 2011

    Energy AutomationPage 5 V 1.0

    Siprotec 5 Line ProtectionScope of devices

    Definition by main protection functions and main differentiating features:

    7 xx yy

    7SA .. Distance protection

    7SD .. Differential protection

    7SL .. Dist. + Diff. protection =

    7VK .. Breaker Management

    2 in 1

    ... 84 3pole tripping, HW not expandable

    ... 86 3pole tripping, HW expandable/changeable

    ... 87 1/3pole tripping, HW expandable/changeable

    7SA84 7SA86 7SA87 7SD84 7SD86 7SD87 7SL86 7SL87 7VK87

    Distance

    Protectionx x x

    Differential

    Protectionx x x

    Dist. + Diff.Protection

    x x

    Breaker

    Managementx

    3pole tripping x x x x x

    1/3pole tripping x x x x

    Hardware

    extendablex x x x x x x

    Main Protection

    Main Features

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    6/18

    Energy Sector

    Siemens AG 2011

    Energy AutomationPage 6 V 1.0

    Siprotec 5 Line Protection

    Standard variants

    Type 1 1/3, 4I, 4U, 7BI, 14BO, 16 LED

    Type 2 1/3, 4I, 4U, 11BI, 9BO, 16 LED

    Type 3 1/2, 4I, 4U, 13BI, 21BO, 16 LED

    Type 4 1/2, 4I, 4U, 19BI, 30BO, 16 LED

    Type 5 1/2, 4I, 4U, 21BI, 17BO(4P), 16 LED

    Type 6 1/2, 4I, 4U, 15BI, 18BO(4HS), 16 LED

    Type 7 1/2, 8I, 8U, 15BI, 20BO, 16 LED

    Type 8 2/3, 4I, 4U, 31BI, 46BO, 16 LEDType 9 2/3, 4I, 4U, 29BI, 23BO(4P), 16 LED

    Type 10 2/3, 4I, 4U, 27BI, 34BO(4HS), 16 LED

    Type 11 2/3, 8I, 8U, 27BI, 36BO, 16 LED

    Type 12 5/6, 8I, 8U, 27BI, 33BO(8HS), 16 LED

    Plug In modules

    Free configuration on

    existing ports

    Standard variants simplify the ordering process with regards to hardware configuration The product code is automatically built within the Configurator

    One type only ! 1/3, 4I, 4U, 5BI, 8BO, 16 LED

    7xx86/87 HW expandable and changeable!

    7xx84 HW not expandable !

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    7/18Energy Sector

    Siemens AG 2011

    Energy AutomationPage 7 V 1.0

    Siprotec 5 Line Protection

    Ordering configuration

    Example:

    7SL87-AAAA-AA0-0AAAA0-AA2111-12111A-DAA000-000AA0-CH1BA1-CF0

    All configuration criteria are coded within the Long Product Code

    The first 5 digits define the Device Type device specific base price

    The Hardware Configurationis based on common module system common price structure

    The Functional Classdefines the number of needed function pointscommon price structure

    Significant Property(position 21) define major price offsets device specific Add-On price

    which cannot be addressed by function points.

    Actually used for 7SD/7SL only:

    1 2 line ends

    2 3 line ends

    3 6 line ends

    Device Type Significant Property

    Functional Class

    Hardware Configuration

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    8/18Energy Sector

    Siemens AG 2011

    Energy AutomationPage 8 V 1.0

    Content

    Content

    Product portfolio

    New applications and functions

    Scope of functions and

    application templates

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    9/18Energy Sector

    Siemens AG 2011

    Energy AutomationPage 9 V 1.0

    Protection news

    New applications with one device

    1,5 circuit breaker 2 breaker, double busbar

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    10/18Energy Sector

    Siemens AG 2011

    Energy AutomationPage 10 V 1.0

    Protection news

    Power Swing: Two functions

    Power Swing Blocking (ANSI 68)

    Avoids uncontrolled tripping of the distance

    protection Operates under symmetrical load conditions as

    well as during single-pole auto-reclose cycles

    Requires no settings

    Can be configured separately to block each

    distance zone

    Evaluates the impedance trajectory of the

    positive sequence impedance Provides a response characteristic with up to 4

    impedance zones in the R/X plane

    Operates independently from settings of distance

    protection zones

    Increments counters depending on the point at

    which the impedance trajectory enters or exits

    the associated impedance zone

    Out-of-step protection (ANSI 78)

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    11/18Energy Sector

    Siemens AG 2011Energy AutomationPage 11 V 1.0

    Protection news

    New protection for STUB BUS

    Separate function for STUB protection

    based on a differential protection principle

    Both CTs connected with one protection device

    (HW configuration with 8I/(8U) needed) No PDI communication required

    High speed 3pole tripping

    Activation through binary input by disconnector QB

    Available for 7SA, 7SD, 7SL

    Settings similar to 87L except communicationrelated parameters

    QA2

    QA1

    BB 1

    BB 2

    A-

    B-

    Line

    1,5 circuit breaker topology

    QB

    STUB BUS

    protection area

    STUB differential protection (ANSI 87 STUB)

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    12/18Energy Sector

    Siemens AG 2011Energy AutomationPage 12 V 1.0

    System function news

    LOGs and Recording

    LOGs Fault Recorder

    Fault LOG

    Operational LOG

    Sensitive ground fault LOG

    New:Setting history LOG

    New:User LOG

    New:Security LOG

    New:Device diagnosis LOG

    New:Physical device history LOG

    New:Communication LOG

    Longer single fault records

    (20s with 8kHz sampling frequency)

    Longer total record time

    (e.g. 120s(8kHz), 1000s(1kHz) , ..)

    Start and save condition configurable

    Flexible configuration of channels

    (analog, binary, measurement values)

    Selectable sampling frequency

    (1kHz, 2kHz, 4kHz, 8kHz)

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    13/18Energy Sector

    Siemens AG 2011Energy AutomationPage 13 V 1.0

    Content

    Content

    Product portfolio

    New applications and functions

    Scope of functions and

    application templates

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    14/18Energy Sector

    Siemens AG 2011Energy AutomationPage 14 V 1.0

    2010 Line ProtectionFunction library for line protection

    Each device type offers a subset of

    available functions !

    ANSI Function

    21, 21N Distance protection [3pol., grounded]

    Distance protection [isolated, compensated]

    Distance protection [1/3pol., grounded]

    21FL Fault locator

    25 Synchronism check

    27 Undervoltage protection-3ph, 3pole

    Undervoltage protection-3ph, 1/3pole

    Undervoltage protection-V1, 3pole

    Undervoltage protection-V1, 1/3pole

    Undervoltage protection-V1 invTUndervoltage protection-Vx

    27WI Measures for weak and zero infeed

    32, 37 32 Power protection-3ph

    46, I2>dir Directional I2-definite-time overcurrent protection

    49 49 Thermal overload protection

    50 Instantaneous overcurrent protection, 1/3pole

    Instantaneous overcurrent protection, 3pole

    51 Overcurrent protection-3phase, 3pole

    Overcurrent protection-3phase, 1/3pole

    51N Overcurrent ground fault protection

    51BF Breaker failure protection, 3pole

    Breaker failure protection, 1/3pole

    59 Overvoltage protection-3ph

    Overvoltage protection-V1

    Overvoltage protection-V1compOvervoltage protection-V0

    Overvoltage protection-Vx

    47 Overvoltage protection-V2

    ANSI Function

    67 Directional overcurrent protection-3phase, 3pole

    Directional overcurrent protection-3phase, 1/3pole

    67N Directional ground fault protection, 1/3pole

    Directional ground fault protection, 3pole

    68 Power swing blocking

    68T Out-of-step protection

    79 Auto. Reclosing

    81 Overfrequency protection

    Underfrequency protection

    85/21 Teleprotection for distance protection85/67N Teleprotection for directional ground fault protection

    87L Line differential protection, 3pole

    Line differential protection, 1/3pole

    87 STUB Stub differential protection

    Swich on to fault detection

    Inrush detection

    Measured values (standard and extended)

    Fault recorder

    Monitoring and supervisionTrip-circuit supervision

    Test functions

    Phasor measurement

    CFC

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    15/18Energy Sector

    Siemens AG 2011Energy AutomationPage 15 V 1.0

    Application templates

    Overview

    3-pole tripping functions only 1/3-pole tripping functions

    Device Types

    Application Template 7SA84 7SD84 7SA86 7SD86 7SL86 7SA87 7SD87 7SL87 7VK87

    DIS Basic X X X

    DIS MV compensated / isolated

    starpoint (with AR)X X X

    DIS HV overhead line, solid earthed

    starpointX X X

    DIS MhoHV overhead line, solidearthed starpoint

    X X

    DIS HV overhead line, solid earthedstarpoint, 1,5 CB

    X X

    DIS MhoHV overhead line, solid

    earthed starpoint, 1,5 CBX

    DIFF Basic X X X

    DIFF overhead line X X X

    DIFF overhead line with transformer X X X

    DIFF overhead line, 1,5 CB X X

    DIFF DIS Basic X X

    DIFF DIS HV overhead line, solid

    earthed starpointX X

    DIFF DIS MhoHV overhead line, solidearthed starpoint

    X

    DIFF DIS overhead line, 1,5 CB X X

    DIFF DIS Mhooverhead line, 1,5 CB X

    7VK87 - Basic ( AR, Sync., Breaker

    fail. prot.)

    X

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    16/18Energy Sector

    Siemens AG 2011Energy AutomationPage 16 V 1.0

    Application template

    7SD8 Diff overhead line

    Tripping: 3pole only (7SD84/86) or 1/3pole (7SD87)

    Main1 = differential protection

    Emergency / Reserve = non directional overcurrent protection (50/51)

    CB functions: breaker failure protection(50 BF) , auto reclose (79), synch check (25)

    Supplementary: voltage(27/59) and frequency protection(81), external trip initiation, switch onto fault

    Basic configuration included (MP, FG, FN, FB, PDI)

    mmQA

    T1.1

    T5

    BB

    Busbar with single line feeder

    U4

    U1

    U2

    U3

    I1

    I2

    I3

    MP

    VT-1ph 1

    MPCT-3ph 1

    MP

    VT-3ph 1

    FG Line FG CB

    50BF

    25

    79

    BI

    BO

    to

    CB QA

    FL

    7SD8: AT Overhead line

    I-3ph

    U-3ph

    IF IF87L

    U-1ph

    I-3ph

    U-3ph

    FG PDC

    SI PDC

    50 51N

    SOTF

    27 59

    51

    Ctrl

    CB

    T1.2I4

    PDI

    Protection data

    interface 1

    81

    PDI

    FG function groupe

    MP measurement point

    PDI/C protection data interface/communication

    CB circuit breaker

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    17/18

    Energy Sector Siemens AG 2011

    Energy AutomationPage 17 V 1.0

    Application template

    7SD8 Diff overhead line, 1,5 CB

    Tripping: 3pole only (7SD84/86) or 1/3pole (7SD87) Main1 = differential protection Emergency / Reserve = non directional overcurrent protection(50/51) 1,5 CB special: 2x breaker failure protection(50BF) , 2x auto reclose(79), 2x synch check(25), STUB-BUS protection Supplementary: voltage(27/59) and frequency protection(81), external trip initiation, switch onto fault Basic configuration included (MP, MN, FG, FN, FB, PDI)

    mm

    mm

    QA2

    QA1mm

    BB 1

    BB 2

    U4

    U1

    U2

    U3

    U4

    I1

    I2

    I3

    I4

    FG Line FG CB A-QA

    50BF

    25

    79

    BI

    BOtoCB A- QA

    FL

    I1

    I2

    I3

    I4

    U1

    U2

    MN (+)

    FG CB B-QA

    50BF

    Ctrl

    BI

    BOto

    CB B- QA

    A-

    B-

    U3

    5927 81

    Line

    7SD8: AT Overhead line for 1,5 CB

    MP

    VT-1ph1

    1,5 circuit breaker topology

    MPCT-3ph 1

    MPVT-3ph1

    MPCT-3ph 1

    I-3ph

    U-3ph

    U-3ph

    I-3ph

    U-3ph

    I-3ph

    U-1ph

    IF IF

    IF

    U-1ph

    CB

    CB

    25

    79

    Ctrl

    MP

    VT-1ph1

    FG PDC 2PDCPDCFG PDC 1

    SI

    SI

    Protectiondatainterface1

    Protectiondatainterface2

    PD I PD I

    51N50 51

    SOTF

    PD I

    87

    FG function groupe

    MP measurement point

    PDI/C protection data interface/communication

    C B circuit breaker

    QB

    87 STUB

    Next click next page

  • 7/22/2019 SIPROTEC 5 - Line Protection Devices_V1.0_en-US

    18/18

    Energy Sector Siemens AG 2011

    Energy AutomationPage 18 V 1 0

    Takeaways / Call to Action

    SIPROTEC 5 line protection devices cover applications in transmission,sub transmission and distribution markets

    Quicker Application templates, copy/paste

    Modular Perfectly tailored hardware and functionality

    Safer Integrated monitoring and supervision

    Better New and improved functions

    Thank you !