IL RUOLO DEGLI AMBIENTI NELLA TRASMISSIONE DELLE INFEZIONI UPDATE SUI SITEMI DI DISINFEZIONE AMBIENTALE NO-TOUCH ED IL CONTROLLO SFRUTTANDO ATP IN BIOLUMINESCENZA MILENA SORRENTINO milena sorrentino

Upload: vuongkiet

Post on 14-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

IL RUOLO DEGLI AMBIENTI NELLA TRASMISSIONE DELLE INFEZIONI

UPDATE SUI SITEMI DI DISINFEZIONE AMBIENTALE NO-TOUCH ED IL

CONTROLLO SFRUTTANDO ATP IN BIOLUMINESCENZA

MILENA SORRENTINO

milena sorrentino

http://www.cdc.gov/hai/surveillance/index.html

Background

R. Douglas Scott II, Economist Division of Healthcare Quality Promotion National Center for Preparedness, Detection, and Control of Infectious Diseases

Coordinating Center for Infectious Diseases Centers for Disease Control and Prevention March 2009

(…) annual direct medical costs of HAI to U.S. hospitals ranges from $28.4 to $33.8 billion (…) the benefits of prevention range from a low of $5.7 to $6.8 billion (20% of infections preventable, CPI for all urban consumers) to a high of $25.0 to $31.5 billion (70 percent of infections preventable, CPI for inpatient hospital services).

milena sorrentino

R. Douglas Scott II, Economist Division of Healthcare Quality Promotion

National Center for Preparedness, Detection, and Control of Infectious

Diseases Coordinating Center for Infectious Diseases Centers for Disease

Control and Prevention March 2009 milena sorrentino

Relation of the Inanimate Hospital Environment toEndemic Nosocomial Infection

Dennis G. Maki, M.D., Carla J. Alvarado, B.S., Carol A. Hassemer, B.S., and Mary Ann Zilz, R.N. N Engl J Med 1982; 307:1562-1566

… many epidemics of nosocomial infection have stemmed from reservoirs of pathogens in the inanimate hospital environment, the contribution of the environment, particularly air, surfaces, and fomites, to the acquisition and spread of endemic nosocomial infection is unclear, and the value of routine microbiologic surveillance of the inanimate hospital environment has been controversial. In 1974 the Committee on Infections within Hospitals of the American Hospital Association concluded: The occurrence of nosocomial infection has not been related to levels of microbial contamination of air, surfaces, and fomites . . . meaningful standards for permissible levels of such contamination do not exist . . .

milena sorrentino

milena sorrentino

INFEC

TION

CO

NTR

OL

ASSES

SM

ENT

TOO

LSFO

RA

CU

TE CA

RE H

OSPITA

LSmilena sorrentino

milena sorrentino

HYDROGEN PEROXIDE (HP) - SILVERVAPORIZZATO / AREOSOLIZZATO (NEBBIA SECCA)

PEROSSIDO DI IDROGENO (5-6%) E/O CATIONI D’ARGENTO (50 PPM)

azione biocida mediata dal radicale libero idrossile che si forma dalla decomposizione del perossido in presenza di

catalizzatori forniti dai microorganismi. (effetto

ossidante sulla membrana lipidica del DNA dei

microorganismi)

sono in grado di inattivare gli agenti patogeni inibendo la sintesi delle proteine.

milena sorrentino

ten studies were considered eligible for inclusion in the review (…) Pathogensevaluated included meticillin-resistant Staphylococcus aureus (MRSA), Clostridiumdifficile and multiple bacterial types

The evaluation of the relevant data extracted from the 10 studies included in our review indicates that airborne hydrogen peroxide, either in the form of vapour or dry mist, can be an effective method of disinfection of the hospital inanimate environment.

Few studies have evaluated the use of airborne hydrogen peroxide disinfection as anadjunctive infection control measure in actual hospital practice. These limited relevant dataare favourable, but further studies are needed to assess the effectiveness, safety, costs, andapplicability of this novel method against other available cleaning methods.

milena sorrentino

To analyse two hospital outbreaks caused by MRAB, determine their epidemiology, carbapenem-resistance mechanisms and assess the effectiveness of surface disinfection by vaporized hydrogen peroxide (VHP)

A combination of rigorous infection control measures including strictisolation, education of staff, hand hygiene and surface decontaminationusing VHP halted the outbreak.The results of this study confirm the importance of rigorous infectionprevention and control measures, combined with VHP decontamination incontrolling an outbreak of MRAB.

milena sorrentino

Lead author, year

HP system Pathogen

Sites revealing

contamination before HPV

Sites revealing

contamination after HPV

% Reduction

French, 2004 HPV MRSA 61/85-72% 1/85-1% 98

Bates, 2005 HPV Serratia 2/42-5% 0/24-0% 100

Jeanes, 2005 HPV MRSA 10/28-36% 0/50-0% 100

Otter, 2007 HPV MRSA 18/30-60% 1/30-3% 95

Dryden, 2008 HPV MRSA 8/29-28% 1/29-3% 88

Boyce, 2008 HPV C difficile 11/43-26% 0/37-0% 100

Bartels, 2008 HP dry mist MRSA 4/14-29% 0/14-0% 100

Shapey, 2008 HP dry mist C difficile 48/203-24% 7/203-3% 88

Barbut, 2009 HP dry mist C difficile 34/180-19% 4/180-2% 88

Otter, 2010 HPV GNR 10/21-48% 0/63-0% 100

Efficacy of hydrogen peroxide systems for decontamination of the hospital environment, by health care-associated pathogen

Rutala WA, Weber DJ. Disinfectants used for environmental disinfection and new room decontamination technology. Am J Infect Control. 2013 May;41(5 Suppl):S36-41.

milena sorrentino

milena sorrentino

milena sorrentino

milena sorrentino

(…) the results of the studies that used HPV no-touch

technology (Figure 4), we found a nonsignifi cant reduction in

CDI rates (pRR, 0.52; 95% CI, 0.15– 1.81; P = .30).

milena sorrentino

milena sorrentino

milena sorrentino

Cesarina Curti La disinfezione delle superfici per via aerea (no-touch system) in ambito sanitario: evoluzione negli anni e attualità sui sistemi con perossido d’idrogeno GImPIOS — Vol 3, n. 2, aprile-giugno 2013

milena sorrentino

RISULTATI SISTEMA DI DECOBTAMINAZIONE PER

NEBULIZZAZIONE CON PERIOSSIDO DI IDROGENO (5 – 6

%) E CATIONI D’ARGENTO

milena sorrentino

“BUNDLE" PER DECONTAMINAZIONE NO-TOUCHSYSTEM

1. PULIZIA TERMINALE MANUALE DELL’AMBIENTE

2. CHIUDERE L’AMBIENTE DA DECONTAMINARE, SPEGNERE IMPIANTI DI CLIMATIZZAZIONE E VENTILAZIONE IMPEDIRE, L’ACCESSO AL

LOCALE DA PARTE DEL PERSONALE.

3. DIFFUSIONE DELLA SOLUZIONE (INSERIMENTO DEI DATI RELATIVI

ALLA DIMENSIONE DEL LOCALE)

4. TEMPO DI CONTATTO (2-3 SECONDO SCHEDA TECNICA)

5. AREAZIONE DEL LOCALE (ATTIVAZIONE CLIMATIZZAZIONE E

VENTILAZIONE) TRATTATO E SMALTIMENTO DELLA CARTUCCIA

milena sorrentino

Air Disinfection

Disinfectant spray-fog techniques for antimicrobial control in hospital rooms has been used. This technique of spraying of disinfectants is an unsatisfactory method of decontaminating air and surfaces and is not recommended for general infection control in routine patient-care areas.

Rutala WA, Weber DJ, HICPAC. Guideline for Disinfection and Sterilization in Health-Care Facilities, 2008.

More research is required to clarify the effectiveness and reliability of fogging,UV irradiation, and ozone mists to reduce norovirus environmental contamination.(No recommendation/unresolved issue)

Taranisia MacCannell et al Guideline for the Prevention and Control of Norovirus Gastroenteritis Outbreaks in Healthcare Settings, 2011,

http://www.cdc.gov/hicpac/norovirus/tables/grade-table-Q3-copcp-vp.html#edmilena sorrentino

milena sorrentino

RILEVAZIONE ADENOSINTRIFOSFATO (ATP)

• UTILIZZANDO UN SISTEMA PER LA RILEVAZIONE DI ADENOSINTRIFOSFATO (ATP), È POSSIBILE

CONOSCERE IL GRADO DI IGIENE DI UNA SUPERFICIE, DELLO STRUMENTARIO CHIRURGICO O DI

UN ENDOSCOPIO RIPROCESSATO, OTTENENDO UNA MISURAZIONE OGGETTIVA, PUNTUALE,

RIPETIBILE E ARCHIVIABILE DIGITALMENTE.

milena sorrentino

L'ATP è la fonte di energia di base per tutte le cellule vegetali,

animali e microbiche e, di conseguenza, la sua presenza su

superfici ambientali fornisce una stima della presenza di sostanza

organica, compresa la contaminazione microbiologica . I test di

bioluminescenza sono basati su una reazione chimica catalizzata dalla luciferasi, come mostrato nella seguente equazione:

Griffith, C.J., Cooper, R.A., Gilmore, J., Davies, C., and Lewis, M. An evaluation of hospital cleaning regimes and standards. J Hosp Infect. 2000; 45: 19e28

Adenosintrifosfato (ATP)

milena sorrentino

La quantità di luce (bioluminescenza) generata da questa reazione, che è proporzionale alla quantità di ATP presente, è espressa

come unità di luce relativa (RLU) / s. Pertanto, la misurazione dell'intensità luminosa da parte dei bioluminometri consente un

rapido monitoraggio della pulizia fornendo una misura sensibile standardizzata del materiale organico totale presente. Diversi studi

sono stati condotti per accertare se il monitoraggio della bioluminescenza ATP potesse essere utilizzato in contesti sanitari come metodo di valutazione per la decontaminazione ambientale

Adenosintrifosfato (ATP)

milena sorrentino

milena sorrentino

milena sorrentino

Authors, year [reference] Setting Samples/sites, number ATP bioluminescence tool ATP benchmark

Griffith et al., 2000 [11][11] General hospital (UK) 31 sitesbBiotrace Cleantrace system (Biotrace Ltd.)

500 RLU/s

Ferreira et al., 2011 [15][15]

Philanthropic hospital (Brazil) 100 sitesbClean-Trace ATP System (3M)

500 RLU/s

Boyce et al, 2010 [16][16]500-bed university affiliated hospital (U.S.)

294 samplesbClean-Trace ATP System (3M)

250 RLU/s

Willis et al, 2007 [17][17] Three hospital wards (UK) 54 sitescHygiena system (Hygiena Int. Ltd.)

100 RLU/s

Anderson et al, 2011 [18][18]

District general hospital (UK) 44 sitescSystemSure Plus system (Hygiena Int. Ltd.)

100 RLU/s

Cooper et al, 2007 [19][19] Four acute hospitals (UK) 552 samplesa547 samplesbBiotrace Cleantrace system (Biotrace Ltd.)

500 RLU/s

Moore et al, 2010 [20][20]Two central London teaching hospitals (UK)

400 samplesa400 samplesbClean-Trace ATP System (3M)

250 RLU/s500 RLU/s

Lewis et al, 2008 [21][21]1300-bed teaching hospital (UK)

180 samplesbBiotrace Cleantrace system (Biotrace Ltd.)

250 RLU/s

Mulvey et al, 2011 [22][22]Teaching hospital Glasgow (UK)

90 samplesa90 samplesbHygiena system (Hygiena Int. Ltd.)

250 RLU/s

Sherlock et al, 2009 [23][23]

700-bed adult tertiary referral hospital (UK)

120 samplesa120 samplesbBiotrace Cleantrace system (Biotrace Ltd.)

500 RLU/s

Boyce et al, 2011 [25][25]500-bed university affiliated hospital (U.S.)

500 sitesa500 sitesbClean-Trace ATP System (3M)

250 RLU/s

Boyce et al, 2009 [27][27]University affiliated community teaching hospital (U.S.)

510 samplesa503 samplesbClean-Trace ATP System (3M)

250 RLU/s

milena sorrentino

VANTAGGI E BENEFICI…•VALUTAZIONE DELLA PULIZIA DELLO STRUMENTARIO CHIRURGICO IN MENO DI UN MINUTO

•MONITORAGGIO DELL’EFFICACIA DEL RICONDIZIONAMENTO DI UN ENDOSCOPIO O DI UNO STRUMENTO CHIRURGICO

•CONTINUO MIGLIORAMENTO DEL LIVELLO DI PRESTAZIONE

•AZIONE CORRETTIVA IMMEDIATA

• SITUAZIONE TRASPARENTE DEL LIVELLO DI IGIENE DELLA STRUTTURA OSPEDALIERA

• RISPETTO DELLE NORME IGIENICHE OSPEDALIERE

• DATI DA ARCHIVIARE ED ELABORARE PER UNA MIGLIORE RINTRACCIABILITÀ

• SALVAGUARDIA DELL’IMMAGINE DELLA STRUTTURA

•Direzione Ospedaliera

•Comitato Infezioni Ospedaliere (C.I.O)

•Per chi si occupa di Pulizia

•Operatori Sanitari

•Pazienti

…per tutti

APPLICAZIONI

ENDOSCOPILA NECESSITÀ DI

VALUTARE L’EFFICACIA

DEL PROCESSO DI

PULIZIA MANUALE È

STATO RICONOSCIUTO

COME UNA PARTE

IMPORTANTE DEL

PROCESSO DI

RICONDIZIONAMENTO

DI UN ENDOSCOPIO

FLESSIBILE.

STRUMENTARIO UNO STRUMENTO PULITO

IN MODO INADEGUATO

PUÒ AVERE RESIDUI DI

SPORCIZIA, BATTERI E

VIRUS CHE POSSONO

SOPRAVVIVERE AGLI

AGENTI STERILIZZANTI E

AL PROCESSO DI

STERILIZZAZIONE CON

CONSEGUENTE

POTENZIALE INFEZIONE

CROCIATA.

SUPERFICIUNA PULIZIA NON ADEGUATA PUÒ ESSERE CAUSA DIRETTA E/O INDIRETTA DI INFEZIONI OSPEDALIERE: È QUINDI EVIDENTE L’IMPORTANZA DELL’ADOZIONE DI UN ADEGUATO MONITORAGGIO DELL’IGIENE DELLE SUPERFICI OSPEDALIERE.

MANILE MANI DEGLI

OPERATORI SONO IL

PRINCIPALE VEICOLO DI

TRASMISSIONE DEI

MICRORGANISMI

PATOGENI

NOSOCOMIALI.

VERIFICARNE LA

CORRETTA PULIZIA

Nel 2010, il CDC hanno identificato i principali strumenti e metodi (osservazione diretta, colture di tampone e / o

agar, marcatori fluorescenti e bioluminescenza di adenosina trifosfato) per valutare la pulizia ambientale su

basi più scientifiche. Guh, A., Carling, P., and Environmental Evaluation Workgroup. Options for evaluating environmental

cleaning. (Available at http://www.cdc.gov/HAI/toolkits/Evaluating-Environmental-Cleaning.html)Centres for Disease Control and Prevention, ; 2010

milena sorrentino

Virgilio, Eneide, I, 630

[email protected]

Non ignara mali, miseris succurrere disco