INTELLIGENT DIGITAL SYNCHRONIZING RELAY WITH REAL TIME MONITORING AND

CONTROL

Page 2: Synchronizing Relay

OBJECTIVE :

To develop and implement an innovative digital version of the existing conventional model of analog synchronizing relay, thereby upgrading the existing design, ensuring effective and reliable operation with the compact model at very low design cost.

Page 3: Synchronizing Relay

EXISTING MODEL OF SYNCHRONIZING TROLLEY :

Page 4: Synchronizing Relay

COMPACTNESS OF OUR MODEL:

Page 5: Synchronizing Relay

Block diagram of the proposed model:

Page 6: Synchronizing Relay

Voltage Sampling Circuit:

Page 7: Synchronizing Relay

Frequency Sampling Circuit :

Page 8: Synchronizing Relay

D

PULSE 1CCP1 RE DETECTIONTIMER ON

PULSE 2CCP1 REDETECTIONTIMER OFF

SHIFT =( D/20000uSEC * 120)-180

METHOD OF PHASE SHIFT TECHNIQUE :

Page 9: Synchronizing Relay

Overall Sampling Circuit of the Project

Page 10: Synchronizing Relay
Page 11: Synchronizing Relay

MICROCONTROLLER UNIT

Page 12: Synchronizing Relay
Page 13: Synchronizing Relay

MODEPRIMARY

SAMPLINGCVT

SECONDARY SAMPLING

(230V/ 0-12V)

ADC OUTPUT

MULTIPLICATION FACTOR400

400KV L-L = 110V

L-N = 63.5V

0-3.3V 0-1023

0.66568047337

230KV L-L = 110V

L-N = 63.5V

0-3.3V 0-1023

0.3397341211

110KV L-L = 110V

L-N = 63.5V

0-3.3V 0-1023

0.1624815361

Page 14: Synchronizing Relay

CIRCUIT BREAKER ACTUATION CIRCUIT :

Page 15: Synchronizing Relay

Proposed module of interfacing HMI with the kit

Page 16: Synchronizing Relay
Page 17: Synchronizing Relay

Advancements of the proposed model : 1. The proposed model is a compact digital model.

2. The model also replaces the bulkier trolleys with enhanced operation as it is interfaced with real time monitoring and control.

3. More simpler, effective and reliable synchronization is ensured at very low design cost.

4. Best suited for synchronization at multiple voltage levels

5. Depending on the healthiness of the system, it can be operated in manual or automatic mode.

6. Response time of the relay is less then 20ms, which makes it more efficient compared to the analog ones.

Page 18: Synchronizing Relay

Project testing :

This project was tested and verified in a real time practical environment, by connecting the model to the bus bar protection panel of a 230 KV feeder at 400/230-110 KV substation at Alamathy, Chennai .

It is worthy to be noted that the model was demonstrated in the presence of all Engineers of Alamathy substation and 230KV Korattur substation and was certified to be a quality relay.

Page 19: Synchronizing Relay

End note :

As per our objective, the proposed compact digital model has been proved to offer more enhanced operation as it is interfaced with real time monitoring, thereby ensuring simpler, effective and reliable synchronization at very low design cost.

We thank all our College faculties , mentors and field Engineers for guiding and motivating us throughout the course of project work .