technical schedules a&b for digital interface to switchgear type tests

4
TECHNICAL SCHEDULES A & B FOR SWITCHGEAR PIUs IN ACCORDANCE WITH EST 240-64685228 Type Tests per IED product family Schedule A: Purchasers specific requirements Schedule B: Guarantees and technical particulars of equipment offered 4.1 General Schedule A 4.1.4 Type testing laboratory Specify 4.1.4 SANS/ILAC accreditation of laboratory Specify 4.2 Type Tests (per IED product family) Test Standard Ports* Compliance criteria - Manufacturer product family/series name Specify 4.2.1 Product Safety 1(a) Dielectric withstand IEC 60255-5 - Comply 1(b) Insulation resistance IEC 60255-5 - Comply 1(c) IEC 60255-5 - Comply 2 Enclosure protection SANS 60529 ENC IP1X (rear) 4.2.2 Environmental specifications 1 Cold IEC 60068-2-1 - 2 Dry Heat IEC 60068-2-2 - 3 IEC 60068-2-30 - 4 Vibration IEC 60255-21-1 - Class 2 Response - Class 1 Endurance 5 Shock IEC 60255-21-2 - Class 1 Response - Class 1 Withstand 6 Bump IEC 60255-21-2 - 10g, 16ms, 1000 pulses un-energised. Class 1 7 Seismic IEC 60255-21-3 - Class 1 2kV r.m.s. 50Hz for 1 minute between all terminals to case earth, 1kV across contacts. Insulation resistance greater than 20MW when measured at 500Vd.c. Electrical impulse (1.2/50ms) 5kV 1.2/50ms waveform, 0.5J Protected against ingress of dust particles, dripping water. IP41 (front panel) Protected against access to hazardous parts with the back of a hand. 16 hours at -25 o C (LCD screen operative) -25 o C Test Ad 16 hours tolerance at +55 o C/+70 o C (control room / outdoor application) +55 o C / +70 o C Test Bd Cyclic Temperature and Humidity 25 o C and 95% relative humidity/ 55 o C and 95% relative humidity, 12 + 12 hour cycle +55 o C Test Db Response: 1g, 10 - 150Hz, 1 sweep, energised. Contacts should not close for longer than 2ms. Endurance: 1g 10 – 150Hz, 20 sweeps, un-energised. Contacts should not close for longer than 2ms. Response: 5g, 11ms, 3 pulses in each direction, energised Withstand: 15g, 11ms, 3 pulses in each direction, un- energised Test method A (single axis sine sweep test) 1 – 35Hz, 1 sweep.

Upload: victor-hutahaean

Post on 16-Nov-2015

225 views

Category:

Documents


1 download

DESCRIPTION

Good info

TRANSCRIPT

Type Tests (Family)TECHNICAL SCHEDULES A & B FORSWITCHGEAR PIUs IN ACCORDANCE WITH EST 240-64685228Type Tests per IED product familySchedule A: Purchasers specific requirementsSchedule B: Guarantees and technical particulars of equipment offered4.1GeneralSchedule ASchedule B4.1.4Type testing laboratorySpecify4.1.4SANS/ILAC accreditation of laboratorySpecify4.2Type Tests (per IED product family)TestStandardPorts*Compliance criteria-Manufacturer product family/series nameSpecify4.2.1Product Safety1(a)Dielectric withstandIEC 60255-5-2kV r.m.s. 50Hz for 1 minute between all terminals to case earth, 1kV across contacts.Comply1(b)Insulation resistanceIEC 60255-5-Insulation resistance greater than 20MW when measured at 500Vd.c.Comply1(c)Electrical impulse (1.2/50ms)IEC 60255-5-5kV 1.2/50ms waveform, 0.5JComply2Enclosure protectionSANS 60529ENCProtected against ingress of dust particles, dripping water.IP41(front panel)Protected against access to hazardous parts with the back of a hand.IP1X (rear)4.2.2Environmental specifications1ColdIEC 60068-2-1-16 hours at -25oC (LCD screen operative)-25oC Test Ad2Dry HeatIEC 60068-2-2-16 hours tolerance at +55oC/+70oC (control room / outdoor application)+55oC / +70oCTest Bd3Cyclic Temperature and HumidityIEC 60068-2-30-25oC and 95% relative humidity/ 55oC and 95% relative humidity, 12 + 12 hour cycle+55oC Test Db4VibrationIEC 60255-21-1-Response: 1g, 10 - 150Hz, 1 sweep, energised. Contacts should not close for longer than 2ms.Class 2 Response-Endurance: 1g 10 150Hz, 20 sweeps, un-energised. Contacts should not close for longer than 2ms.Class 1 Endurance5ShockIEC 60255-21-2-Response: 5g, 11ms, 3 pulses in each direction, energisedClass 1 Response-Withstand: 15g, 11ms, 3 pulses in each direction, un-energisedClass 1 Withstand6BumpIEC 60255-21-2-10g, 16ms, 1000 pulses un-energised.Class 17SeismicIEC 60255-21-3-Test method A (single axis sine sweep test) 1 35Hz, 1 sweep.Class 1TECHNICAL SCHEDULES A & B FORSWITCHGEAR PIUs IN ACCORDANCE WITH EST 240-64685228Type Tests per IED product family (concluded)4.2.3Immunity SpecificationsNote: Refer to IEC 60255-26 for an overview of electromagnetic compatibility requirements.1(a) -(c)Voltage dips, interruption, gradial start-up/shut-downIEC 60255-11PS50ms interruption has no effect on operationNo maloperation for 5s interruption.No maloperation for decaying DC over 60s, rising over 60s.Comply1(d)AC rippleIEC60255-11PSDevice shall function correctly with 12% 100Hz ac signal superimposed on the d.c. supply.Comply4.2.3Immunity Specifications (Continued)2Power frequency magnetic fieldSANS 61000-4-8ENC100A/m continuous, 1000A/m 1-3s, 50HzClass 531MHz oscillatory wavesIEC60255-22-1 or SANS 61000-4-18PS, IO2.5kV CM, 1kV DM, 2s total test duration, 6 10 bursts at 400Hz repetition.Class 3COM1kV CM, 0kV DM, 2s total test duration, 6 10 bursts at 400Hz repetition.4Electrostatic DischargeIEC 60255-22-2 or SANS 61000-4-2ENC6kV Contact Discharge, 8kV Air DischargeClass 35Radiated Radio Frequency fieldIEC 60255-22-3 orENC10V/m unmod r.m.s., 80% AM (1kHz), 80MHz 1GHz, 1.4 2.7 GHz-SANS 61000-4-3Class 36Fast TransientIEC 60255-22-4PS, IO, E2kV, 5kHzClass BCOM1kV, 5kHz7SurgeIEC 60255-22-5 or1,2/50ms (8/20ms) voltage (current) surge:-PS, IO0,5; 1; 2 kV line to earth, 0,5; 1 kV line to lineCOM0,5; 1 kV line to earthSANS 61000-4-5PS, IO2kVClass 38Induced Radio Frequency fieldIEC 60255-22-6 orPS, COM, IO, E10Vrms, 150kHz 80MHz-SANS 61000-4-6Class 39Power Frequency immunityIEC 60255-22-7IOAC voltages applied to D.C. inputs: 150V r.m.s. DM, 300V r.m.s. CMClass A4.2.4Emission SpecificationsNote: Refer to IEC 60255-26 for an overview of electromagnetic compatibility requirements.1Conducted emissionIEC 60255-25PS0,15 0,5 MHz: 79dB(mV) quasi peak, 66dB(mV) ave.-0,5 30 MHz: 73dB(mV) quasi peak, 60dB(mV) ave.2Radiated emissionIEC 60255-25ENC30 230 MHz: 40dB(mV) quasi peak at 10m-230 1000 MHz: 47dB(mV) quasi peak at 10m* Immunity and Emission tests are applicable to specific ports of the Equipment Under Test:-COM: (Rear) communication ports; E: Earth terminal; ENC: Device enclosure; IO: Inputs/Outputs; PS: Power SupplyCM = Common Mode, DM = Differential Mode.

Back

RangesIEC_ESKYes_NoIECYesESKNo