Page 1: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Page 2: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Integrated-OR

Hybrid-OR

Robotic-OR

Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Page 3: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Topics: - Telemedicine

- Multimedia (Cameras, Displays)

- linked to:- HIS Hospital Information System

- RIS Radiology Information System

- PACS Picture Archiving and Communication System

- LIS Laboratory Information System

Page 4: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital communication by hospital IT or Video Distribution System is the basis of the telemedicine system. It collects and organizes the information of all connected imaging devices required foreach procedure.

The data of the imaging devices can be displayed by different monitors at any place and digitally archived.

This means that the system fulfils all requirements for state of the art medical telecommunications:

• efficient application in the OR to rapid information exchange• interdisciplinary cooperation• research • training

Digital-OR

Page 5: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Integration of existing image and data sources

The telemedicine system integrates the existing image material quickly and continuously in the OR process. Be it endoscope, microscope, image intensifier, OR light camera, PACS or vital data

Digital-OR

Page 6: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Integrated-OR

Hybrid-OR

Robotic-OR

Modular-OR

Page 7: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Integrated-OR

Digital OR + Centralized control of devices in the OR

• Manage endoscopic and peripheral devices, e. g. Room- + OR-Light, OR-Table via dedicated IT-Interfaces

• View, display, document and communicate information from video and other data sources in and out of the OR.

Page 8: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Integrated-OR

Hybrid-OR

Robotic-OR

Modular-OR

Page 9: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Operating Theatre + Imaging device, e.g.:

• Angio-System

• CT

• MRI

Hybrid-OR

Page 10: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

DVE 3 /CSU 3

DVE 4 /CSU 4

DVE 2 /CSU 2

DVE 1 /CSU 1

Hybrid-OPUNTERSUCHUNG

60x60cm Flanschefür die Ampeln, dürfenbis an diese Linieheran

HINWEIS:

Steriler Bereich

Hybrid-OR

Most Hybrid-OR combine a complete cardio/angio workstation with a cardiovascular OR.

Similar workstations can be used in neuro angiography OR’s.

Page 11: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Hybrid-OR

Page 12: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Integrated-OR

Hybrid-OR

Robotic-OR

Modular-OR

Page 13: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Robotic-OR (Intuitive Surgical)

Example: da Vinci Surgical System by Intuitive Surgical

Surgeon Console

Patient-side Cart

Video System

Page 14: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Example: da Vinci Surgical System by Intuitive Surgical

“The da Vinci Surgical System consists of an ergonomically designed surgeon’s console, a patient-side cart with four interactive robotic arms, the high-performance InSite® Vision System and proprietary EndoWrist® Instruments. Powered by state-of-the-art robotic technology, the surgeon’s hand movements are scaled, filtered and seamlessly translated into precise movements of the EndoWrist Instruments. The net result: an intuitive interface with breakthrough surgical capabilities.”

Robotic-OR (Intuitive Surgical)

Page 15: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Integrated-OR

Hybrid-OR

Robotic-OR

Modular-OR

Page 16: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Modular - OR ( Built –in OT )

Page 17: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Wall System made of removable panels (Modules)

• especially for areas where High-Tec meets Hygiene: OR, Cathlab, CSSD, Laboratory

• applicable in new buildings as well as refurbishments

Modular - OR ( Built –in OT )

Page 18: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Stainless steel : AISI 304

• Color solution based on customer choice from NCS or RAL color book

Wall panel

Modular - OR ( Built –in OT )

Page 19: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

2 panels solution

• Bottom panel

standard size 2000x1200 mm

• Top panel

standard size 900x1200 mm

Wall panel – OPTION No. 1

Modular - OR ( Built –in OT )

Page 20: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

3 panel solution

• Bottom panel

standard size 900x1200 mm

• Middle installation panel standard size 200x1200 mm

• Top panel

standard size 1800x1200 mm

Wall panel – Option No. 2

Modular - OR ( Built –in OT )

Page 21: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Body from aluminum – powder coated

• Light fittings with dimming function • HEPA H14 filtration • Laminarizator

Laminar flow – main components

Modular - OR ( Built –in OT )

Page 22: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Serves from air exhaust from room

• Body made from zinc coated steel

• Stainless steel grids AISI 304 or AISI 316

Exhaust channel

Modular - OR ( Built –in OT )

Page 23: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Size 600x1200 mm, same as ceiling cassettes

• Number of light fittings depends on lighting intensity calculation and equability in the OT

• IP 65 protection • Electric stabilizer for dimming

function • Light fitting control from control

panel• Service access without using

tools

Lighting

Modular - OR ( Built –in OT )

Page 24: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Size 600x1200 mm• Manufactured from 0,8 mm

thick metal with surface in RAL 9010 shade

• OPTION – stainless steel AISI 304 or 316

• Tight ceiling• Access to installation above

the ceiling through revision cassettes in color matching color of the cassettes

Cassette ceiling

Modular - OR ( Built –in OT )

Page 25: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Any graphic motive can be applied to one or multiple panels

• Panel has same resistance

against the cleaning agents like standard panel

Graphic panels

Modular - OR ( Built –in OT )

Page 26: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Stainless steel AISI 304-316 powder coated with mineral wool filling

• Color solution as requested by customer

• Full, glassed, with or without radiation protection

• Blinds – manual, magnetic, electric

• Hinged, sliding, one wing, two wings

• Door drives as requested by customer

Door systems

Modular - OR ( Built –in OT )

Page 27: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Modern solution

• Hygienic solution

• Touch less function

• Full – partial opening

Touch less sensor for door systems

Modular - OR ( Built –in OT )

Page 28: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Pass through cabinets• Cabinets for operating tools• Cabinets for sewing material• Atypical cabinets – free

standing, built-in

All cabinets can be done in color solution as requested by customer or in same color shade as the wall panels in the OT.

Built-in cabinet

Modular - OR ( Built –in OT )

Page 29: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• 19 inch touch screen• Modern look• Simple control• Language of choice• Serviced outside OT• Connection through internet• 365 days customer support• Spare parts available locally

Touch screen control panel

Modular - OR ( Built –in OT )

Page 30: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Stainless steel AISI 304 (316)

• Highest quality and focus on details

• Touch less sensors

• 1-3 person work stations

• Custom size

Scrub facilities

Page 31: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

• Installation in accordance with local laws and regulations

• Realizations approved by local authorities with no comments

• All other components (doors, cabinets, windows, glassed partitions) are also protected by lead line.

Special solutions – lead line installation

Page 32: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Modular-OR (Dräger)

Advantages:

• coordinated AutoCAD plans out of one hand (incl. wall elevations) • short construction period

• reduced noise + dirt during installation

• highest hygienic standard

• easy to clean + disinfect, high resistance

• simple upgrading of installation inside the walls (reuse of material, no spare parts needed)

Modular - OR ( Built –in OT )

Page 33: Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Term Definitions: Digital-, Integrated-, Hybrid-, Robotic-, Modular-OR

Digital-OR

Integrated-OR

Hybrid-OR

Robotic-OR

Modular-OR